Technical Data
| Data | |
| Connectorsystem | Φ4mm |
| Ratedvoltage | 1000VDC(IEC) |
| Ratedcurrent | 30A |
| Test voltage | 6kV(50HZ,1min) |
| Ambienttemperaturerange | -40°C...90℃(IEC) |
| Upper limiting temper ature | +105℃(IEC) |
| Degreeof protection,mated | IP67 |
| Unmated | IP2X |
| Comtact resistance of plug connectors | 0.5mΩ |
| Safetyclass | Ⅱ |
| Contactmaterial | Messing,verzinnt CopperAlloy, tinplated |
| Insulationmaterial | PC/PA |
| Locking system | Snap-in |
| Flameclass | UL-94-VO |
| Saltmistspraytest,degreeof severity5 | IEC 60068-2-52 |
YMC4H20A
YMC4H25-32A
TechnicalData
| Data | |
| Connectorsystem | Φ4mm |
| Rated voltage | 1000VDC |
| Rated current | 10A,15A, 25-32A |
| Testvoltage | 12kV |
| Ambienttemperaturerange | -40°C...+*85℃ |
| Degreeofprotection,mated | IP68 |
| Unmated | IP2X |
| Comtact resistanceof plug connectors | ≤0.5mΩ |
| Safetyclass | Ⅱ |
| Contactmaterial | Messing,verzinnt CopperAlloy,tin plated |
| Insulationmaterial | PC/PPO |
| Locking system | Snap-in |
| Flameclass | UL-94-VO |
| Salt mist spray test,degree of severity 5 | IEC 62852 |
Technical Data
| Data | |
| Ratedvoltage | 1000V |
| Insulationmaterial | PPO |
| Conductormaterial | Coppertin-plated |
| Ambienttemperature | -40℃~+95℃ |
| Producttemperature | -40℃~+135°℃ |
| Security class | DCII |
| Waterproof grade | IP68 |
| Contact resistance | ≤0.35mΩ |
| Connectionsystem | Multi-pointconnection |
| Self-locking system | Embedded |
| Insertion force | ≤50N |
| Pulling out force | ≥250N |
| Ratedcurrent | 10A/15A/20A/30A |
| Flame retardantrating | UL94-VO |
YMC4H PV Fuse Connector (1500V)
Technical Data
| ProductName | YMC4H-1.5K/A | YMC4H-1.5K/B | YMC4H-1.5K/C | YMC4H-1.5K/D |
| Rated voltage | 1500V | 1500V | 1500V | 1500V |
| Insulation material | PPO | PPO | PPO | PPO |
| Conductormaterial | Coppertin-plated | Coppertin-plated | Coppertin-plated | Coppertin-plated |
| Ambient temperature | -40℃~+95℃ | -40℃~+95℃ | -40℃~+95℃ | -40℃~+95℃ |
| Producttemperature | -40℃~+135℃ | -40℃~+135℃ | -40℃~+135℃ | -40℃~+135℃ |
| Securityclass | DCII | DCII | DCII | DCII |
| Waterproof grade | IP68 | IP68 | IP68 | IP68 |
| Contact resistance | ≤0.35mΩ | ≤0.35mΩ | ≤0.35mΩ | ≤0.35mΩ |
| Connection system | Multi-pointconnection | Multi-pointconnection | Multi-pointconnection | Multi-pointconnection |
| Self-locking system | Embedded | Embedded | Embedded | Embedded |
| Insertion force | ≤50N | ≤50N | ≤50N | ≤50N |
| Pulling out force | ≥50N | ≥50N | ≥50N | ≥50N |
| Ratedcurrent | 10A/15A/20A/30A | 10A/15A/20A/30A | 10A/15A/20A/30A | 10A/15A/20A/30A |
| Flame retardantrating | UL94-VO | UL94-VO | UL94-VO | UL94-VO |
PV-LTM41500VCableConnector 30A/50A
PV-LTM41500VPanelconnector 30A/50A
Technical Data
| Data | |
| Connectorsystem | Φ4mm |
| Ratedvoltage | 1500VDC |
| Rated current | 30A,4mm²/40A,6mm²/50A,10mm² |
| Test voltage | 16kV |
| Ambienttemperaturerange | -40°...+*85℃ |
| Degree of protection,mated | IP68 |
| Unmated | IP2X |
| Comtact resistanceof plug connectors | ≤0.5mΩ |
| Safetyclass | Ⅱ |
| Contact material | Messing,verzinnt CopperAlloy,tin plated |
| Insulationmaterial | PC/PPO |
| Locking system | Snap-in |
| Flameclass | UL-94-VO |
| Salt mist spray test,degree of severity 5 | IEC 62852 |
Technical Data
| Data | |
| InsulationMaterial | PPO |
| Contact Material | Copper,Tin plated |
| SuitableCurrent | 50A |
| Rated Voltage | 1500V |
| TestVoltage | 16KV |
| Contact Resistance | |
| DegreeOfProtection | IP68 |
| Ambient Temperature Range | -40℃~+85℃ |
| FlameClass | UL94-VO |
| Safety Class | Ⅱ |
| PinDimensions | Φ4mm |
TechnicalData
| Data | |
| Connectorsystem | Φ4mm/Φ6mm |
| Ratedvoltage | 1500VDC |
| Ratedcurrent | 30A-50A |
| Testvoltage | 16kV |
| Ambienttemperaturerange | -40C...90°℃ |
| Degree of protection,mated | IP67 |
| Unmated | IP2X |
| Comtact resistance of plug connectors | ≤0.5mΩ |
| Safetyclass | Ⅱ |
| Contactmaterial | Messing,verinnt CopperAlloy, tin plated |
| Insulationmaterial | PC/PPO |
| Locking system | Snap-in |
| Flameclass | UL-94-VO |
| Salt mist spray test,degree of severity 5 | IEC 62852 |
ToolKit 1
Tool Kit 2
A2546BCrimpingTool
WX-206CableCutter
WX-700 Cable Stripper
G 1
WX-0626 Cable Stripper
WX-700B:1-3.2mm WX-700M:2.5-6mm
Suitable for crimping the cable of 2 . 5 { - } 6 . 0 \mathsf {mm } ^ { 2 } (AWGIO-14)
Suitable forsolarsystem installation site,flexibleapplication
PV-connector tool kits
期
① CRIMPINGPLIERS ④ WIRESTRIPPER
·Capacity:2.5-6mm² ·Automatic rebound spring,no damage conductor
·Length:270mm ·Stripping length: < 3 0 \mathsf {mm } (204号
·Weight:0.74Kg ·Wire stripping: 0 . 9 { - } 6 . 0 { m } { m } ^ { 2 } (20 ·Length:165mm
② WIRECUTTERS ·Weight:0.16kg
③ SUNNYTWINSPVSPECIALTOOL ⑤ LARGECRIMPINGPLIERS ·Capacity:6-50mm²
Tow-setspanners
Protection caps
PVCable
Thiscable is specificallydesigned for connectingphotovoltaic system components inside and outside of building and equipment.
Features
Insulation material: Halogen free cross-linked polyolefin(XLPO)
⊚ Contact material: Stranded tinned copper
⊚ Sheath material: Halogen free cross-linked polyolefin(XLPO)
Ratedvoltage:1000V/1500V
⊚ Anti-aging,UVresistant
Certificate:TUV
| Construction (mm²) | Conductorconstruction (nxmm) | Conductorouter (mm) | Cableouter (mm) | ResistanceMax. (Ω/Km) | Currentcarring capacityAT60°℃ (A) |
| 1×1.5 | 30×0.25 | 1.58 | 4.90 | 13.7 | 30 |
| 1×2.5 | 48×0.25 | 2.02 | 5.45 | 8.21 | 41 |
| 1×4.0 | 56×0.3 | 2.35 | 6.10 | 5.09 | 55 |
| 1×6.0 | 84×0.3 | 3.20 | 7.20 | 3.39 | 70 |
| 1×10 | 142×0.3 | 4.60 | 9.00 | 1.95 | 98 |
| 1×16 | 228×0.3 | 5.60 | 10.20 | 1.24 | 132 |
| 1×25 | 361x0.3 | 6.95 | 12.00 | 0.795 | 176 |
| 1×35 | 494×0.3 | 8.30 | 13.80 | 0.565 | 218 |
| Type | Cross Section | Strand design | Conductor diameter | Conductor resistance | Outerdiameter AxB | Rated voltage | Rated current |
| (mm2) | No.xφ(mm) | (mm) | (Ω/Km) | (mm) | VAC/DC | A | |
| Twin Core | |||||||
| PV-2x1.5mm² | 1.5 | 30×0.25 | 1.6 | 13.9 | 5.80×9.30 | 1000/1800 | 20 |
| PV-2x2.5mm² | 2.5 | 50x0.25 | 2.0 | 8.06 | 6.20×9.90 | 1000/1800 | 30 |
| PV-2×4.0mm² | 4.0 | 56x0.3 | 2.6 | 4.97 | 6.9×11.30 | 1000/1800 | 50 |
| PV-2x6.0mm² | 6.0 | 81x 0.3 | 3.3 | 3.52 | 7.1 x14.30 | 1000/1800 | 70 |
Technical Data
| Data | |
| Nominal voltage | DC:1.8KVAC:0.6/1.0KV |
| Voltage testoncompleted cable | AC:6.5KVDC:15KV,5MIN |
| Ambienttemperature | -40°℃~+90° |
| Max.Temperatureat conductor | +120°℃ |
| Servicelife | >25year(-40°C~+90°℃) |
| Refertoshortcirauitallowsthetemperature | 200℃,5s |
| Bending radius | ≥4XΦ(D |
| Resistance against acid and alkaline solution | EN60811-2-1 |
| Coldbending test | EN60811-1-4 |
| Weathering/UV-resistance | HD605/A1 |
| 0-zoneresistanceatcompletecable | EN50396 |
| Test under fire conditions | EN60332-1-2 |
Single core wire structure
| Tiem | Unit | Technicalparameter | ||
| Ratedtemperature | ℃ | -40~+90 | ||
| Rated Rating | AC/DC(kV) | AC Uo/U0.6~1.0kV,DC1.5kV | ||
| CableCore | No. | 1 | ||
| Cross-Section Area | mm² | 2.5 | 4.0 | 6.0 |
| Diameterofwires/Number | NO./mm | 36/0.285mm | 56/0.285mm | 84/0.285mm |
| Thickness of the Insulation | mm | ≥0.65 | ≥0.75 | ≥0.8 |
| Thicknessof the Sheath | mm | ≥0.65 | ≥0.7 | ≥0.75 |
| Outer Dia. | mm | 5.3±0.1 | 5.8±0.1 | 6.6±0.1 |
| Conductor resistance(20℃) | Ω/km | ≤8.21 | ≤5.09 | ≤3.39 |
| Voltage test on completed cable | kV/min | 6.5/5No breakdown | ||
Double corewire structure
| Tiem | Unit | Technicalparameter | ||
| Ratedtemperature | ℃ | -40~+90 | ||
| Rated Rating | AC/DC(kV) | AC Uo/U0.6~1.0kV,DC1.5kV | ||
| CableCore | No. | 2 | ||
| Cross-Section Area | mm² | 2.5 | 4.0 | 6.0 |
| Diameterofwires/Number | NO./mm | 36/0.285mm×2 | 56/0.285mm×2 | 84/0.285mm×2 |
| Thickness of the Insulation | mm | ≥0.65 | ≥0.75 | ≥0.8 |
| Thickness of the Sheath | mm | ≥0.65 | ≥0.7 | ≥0.75 |
| Outer Dia. | mm | 11.5×5.3±0.2 | 13.0×5.8±0.2 | 15×7.0±0.2 |
| Conductorresistance(20℃) | Ω/km | ≤8.21 | ≤5.09 | ≤3.39 |
| The service lifeof the theory | kV/min | 6.5/5No breakdown | ||
Residual Current Devices
YRL7-636kA SERIESYRL7-63PRO10KA SERIESACMiniatureCircuitBreaker
Application
IEC6089810kAOMCBcan 1 0 0 % pass10kA Over20,ooo cyclesmechanicaland electrical endurance operation
Technical Data
| Electrical Features | |
| Rated current (In) | 1-63A |
| Pole | 1P2P 3P4P |
| Ratedvoltage(Ue) | 1P:240/415V~ 2/3/4P:415~ |
| Insulation voltage (Ui) | 500V |
| Ratedfrequency | 50/60Hz |
| Rated breaking capacity(Icn) | 10kA |
| Rated operating short circuit breaking capacity (Ics) | 7.5kA |
| Energy limiting class | |
| Tripping curve | BCD |
| Electrical and Mechanical life | 20000 |
| Rated current | 1:1A,2:2A,3:3A,4:4A,6:6A,10:10A,16:16A, 20:20A,25:25A,32:32A,40:40A,50:50A,63:63A |
| Combinationwithaccessories | |
| Auxillarycontact | YES |
| Alarm contact | YES |
| Shuntrelease | YES |
| Undervoltage release | YES |
TrippingCharacteristics
| TestProcedure | Type | TestCurrent | Initial State | TrippingorNon-tripping Time Limit | ExpectedResult | Remark |
| A | BCD | 1.13In | Cold | t≤1h | no tripping | |
| B | BCD | 1.45In | AftertestA | t≤1h | tripping | Thecurrent steadilyrifes to the valuewithin5s |
| C | BCD | 2.55In | Cold | 1s | tripping | |
| D | B | 3In | Cold | t≤0.1s | no tripping | Turnon the switchitoclose thecurrent |
| C | 5In | |||||
| D | 10In | |||||
| E | B | 5In | Cold | t≤0.1s | tripping | Turn on the switchtoclose thecurrent |
| C | 10In | |||||
| D | 20In |
| PackageInformation Storage | |||||
| Current | Pole | Box | Carton | Products should be stored in the warehouse where there is ventilation.The relative humidity thereshould notexceed80%,andtheambienttemperature thereisbetween-40°Cto+85C. Inaddition,there should not be acidic,alkalineand corrosive gas in the air. | |
| 63A/32A | 1P | 12 | 120 | ||
| 2P | 6 | 60 | |||
| 3P | 4 | 40 | |||
| 4P | 3 | 30 | |||
ReductionCoefficient
| Altitudereductioncoeficient | ||||
| Altitude (m) | 2000 | 3000 | 4000 | 5000 |
| Rated Current (In) | 1 | 0.97 | 0.91 | 0.86 |
| Rated Insulation (Ui) | 1 | 0.90 | 0.82 | 0.76 |
| Power-Frequency DielectricStrength | 1 | 0.90 | 0.82 | 0.76 |
| Rated Impact Tolerance Voltage (Uimp) | 1 | 0.90 | 0.82 | 0.76 |
| Values Of Rated Shour-Circuit Capacity (lcn) | 1 | 0.87 | 0.77 | 0.67 |
| ElectricalLife(Cycles) | 1 | 0.87 | 0.77 | 0.67 |
| -30°℃ | -25℃ | -20°℃ | -15℃ | -10℃ | -5°℃ | 0℃ | 5°℃ | 10℃ | 15℃ | 20℃ | 25℃ | 30℃ | 35℃ | 40℃ | 45℃ | 50℃ | 55℃ | 60℃ | |
| 16A | 1.24 | 1.22 | 1.20 | 1.18 | 1.16 | 1.14 | 1.11 | 1.09 | 1.07 | 1.05 | 1.02 | 1.00 | 1.00 | 1.00 | 1.00 | 0.90 | 087 | 0.84 | 0.81 |
| 20A | 1.23 | 1.21 | 1.19 | 1.17 | 1.15 | 1.13 | 1.11 | 1.09 | 1.07 | 1.05 | 1.02 | 1.00 | 1.00 | 1.00 | 1.00 | 0.90 | 0.87 | 0.84 | 0.81 |
| 25A | 1.24 | 1.22 | 1.20 | 1.18 | 1.16 | 1.14 | 1.11 | 1.09 | 1.07 | 1.05 | 1.02 | 1.00 | 1.00 | 1.00 | 1.00 | 0.90 | 0.87 | 0.85 | 0.82 |
| 32A | 1.23 | 1.21 | 1.19 | 1.17 | 1.15 | 1.13 | 1.11 | 1.09 | 1.07 | 1.04 | 1.02 | 1.00 | 1.00 | 1.00 | 1.00 | 0.91 | 0.88 | 0.85 | 0.78 |
| 40A | 1.23 | 1.21 | 1.19 | 1.17 | 1.15 | 1.13 | 1.11 | 1.09 | 1.07 | 1.05 | 1.02 | 1.00 | 1.00 | 1.00 | 1.00 | 0.91 | 0.88 | 0.85 | 0.82 |
| 50A | 1.23 | 1.21 | 1.19 | 1.17 | 1.15 | 1.13 | 1.11 | 1.09 | 1.07 | 1.05 | 1.02 | 1.00 | 1.00 | 1.00 | 1.00 | 0.91 | 0.88 | 0.85 | 0.82 |
| 63A | 1.27 | 1.25 | 1.22 | 1.20 | 1.18 | 1.15 | 1.13 | 1.11 | 1.08 | 1.05 | 0.87 | 1.00 | 1.00 | 1.00 | 1.00 | 0.88 | 0.85 | 0.82 | 0.78 |
| 80A | 1.27 | 1.25 | 1.22 | 1.20 | 1.18 | 1.15 | 1.13 | 1.11 | 1.08 | 1.05 | 0.87 | 1.00 | 1.00 | 1.00 | 1.00 | 0.88 | 0.85 | 0.82 | 0.78 |
Installation
| Contactpositionindicator | Yes |
| Protection degree | IP20 |
| Referencetemperatureforsettingofthermalelement | 30°℃ |
| Ambienttemperature | -5~+40℃ and its average overa period of 24h does not exceed +35℃ |
| Storagetemperature | -25~+70℃ |
| Terminal connection type | Cable/U-typebusbar/Pin-typebusbar |
| Terminalsizetop/bottomforcable | 25mm² |
| Tightening torque | 2.5N.m |
| Mounting | OnDINrailFN60715(35mm)bymeansof fastclipdevice |
| Connection | Top and bottom |
Dimensions
Unit: mm
YRCB-63 SERIESMiniatureCircuitBreaker
TechnicalData
| MCB | Technical Data | ||
| Tripping Curve | B,C,D | Standard | IEC60898-1 |
| NumberofPoles | 1230/6//2/32/40/5/GA | Rred btriaking hoptcity | Icu(kA):6kA |
| Rated Operation Voltage Ue | 230AC for1P;400ACfor2,3,4P | Rated service short- circuitbreakingcapacity | Ics(kA):6kA |
| Rated Insulation Voltage Ui | 415V | ||
| Rated Frequency | 50/60Hz | Type ofrelease Protection Index | Thermo-magnetic |
| Rated Impulse withstand Voltage Uimp | 4kV | Ambient Temperature | IP20 at30℃ |
| RatedCurrent In(A) | Eachumpemnximum power | RatedCurrentIn(A) | Eachumletimnximumpower |
| In≤10 | 3 | 32 | |
10| 3.5 | 40 | 7.5 9 | |
16| 4.5 | 50 | 13 | |
25| 6 | | ||
Dimensions
Unit: mm
YRL7-63 WIFISERIES CircuitBreaker
Overview
YRL7-63WlFl series circuit breaker isan electrical terminal distributiondevice developed for smart and secure power consumptionandenergymanagementsystemsinbuildings.
This product isan loT circuit breaker that uses electronic technology to control thenormal operation of traditional circuitbreakers.Ithas functionssuchas remoteopening and closing control,local mode selection,timed opening andclosingsettings,and energymetering.
Functional Features
⊚ Supportsmultiple control platformssuch as YROAPP, Cloud Intelligent APP,RS485,WeChat Mini Program.
\odot Supports local orremoteoperation for turning onand off
⊚ Supports DIN-rail mounting.
⊚ Remote control without distance limitations.
\odot Supportscustomizationof protection thresholds.
⊚ Supports over/undervoltage,overcurrent,and overload protection.
⊚ Supportsautomatic reclosing and customizable reclosing time configuration.
TechnicalData
| Poles | 1P |
| Mounting poles | 2P |
| Ratedcurrent | 10A、16A、25A、32A、40A、50A、63A、80A、 100A |
| Rated corking voltageand frequency | 220/230VAC 50Hz |
| Breakingcapacity | 6KA |
| Type | Type C.Type D |
| Standbypowerconsumption | |
| Communication | YRO WIFI/RS485 |
| Trippingtime | ≤0.1 |
| Short circuit time | ≤0.048 |
| InternationalStandard | EN/IEC60898-1 |
| Control mode | Integratedmanualandautomaticcontrol |
| Installationrequirements | Theinstallation location'saltitudeshouldnotexceed 3000m |
| Temperaturerequirements | The lower limit of ambient air temperature should not be lower than-20C, and theupperlimit should notexceed+70℃ |
| IPrating | IP20 |
| Product size | 98.5mm*36mm*50mm |
| Configurableparameters | Powerstatistics、Over-voltage protection、Over-current protection、Overload protection |
PanelDiagram
Wiring&Dimensional Diagram
Unit: mm
YRCB-4O WIFISERIES IntelligentRelay Switch
Overview
YRCB-40 WlFl series single-phase rail-mounted intelligent relayswitch isa product that meetsusers'needs forcircuit protection and control.
Theproduct features functions such as metering,timing, fault protection,remote control,and local control.
Functional Features
⊚ Supportsmultiple control platformssuch as YROAPP.
⊚ Supports local orremote operation for turning onandoff.
⊚ Supports DIN-rail mounting.
⊚ Remote control without distance limitations.
\odot Supports customization of protection thresholds.
TechnicalData
| Referencevoltage | 220V、230V |
| Specifiedoperating voltage | 90% Un~110% Un |
| Extendedoperatingvoltage | 80%Un~Un~115%Un |
| Current specification | 6-63A |
| Frequency range | (50-60) Hz |
| Powerconsumption | Voltage circuit:≤1.5W |
| Communication | YROWIFI |
| Operatingtemperature | -20℃~70℃ |
| Operating humidity | ≤95% |
| Dustproofandwaterproof | IP20 |
| Product size | 91.3mm*18mm*66.5mm |
| Measurement Accuracy | Voltageand currentaccuracy:1% |
| Energy accuracy:2% | |
| Overvoltage protection Undervoltage protection | Protectionswitch:overvoltage value;recoveryvalue;judgmentand recovery time. Protection switch:undervoltage value;recovery value;judgment and recovery time. |
| Overcurrentprotection | Protectionswitch:overcurrentvalue;judgmenttime. |
| Overpower protection | Protection switch:over powervalue;judgmenttime. |
PanelDiagram
Wiring&Dimensional Diagram
RCCB/RCBOSERIES Residual CurrentDevices
OperatingPrinciple
Protection from electric shocks by direct contact:
Protection of persons against electric shock by directcontact 3 0 ~ \mathsf { m A } )
Protection of installations against the risk of fire (20号 ( 3 0 0 m A ) :
Protection of persons against electric shock by indirectcontact( 1 0 0 \mathsf { m A } to 3 0 0 \mathsf { m A } 0
Researchworldwideshowsthatthe intensityof current flowing through the bodydetermines the extentand severityofan electricshock.
Bymeasuringthe intensity difference between live and neutral conductors,RCDs actually detect the current fowing through the human body.If this current reaches the 3 0 ~ \mathsf { m A } limit,the RCD trips within a few milliseconds,so preventing injury orworse.
Injuriesbecomeseriouswhencurrentsexceed 4 0 m A to 50mAduring one second.
Theoretically,a 1 5 0 \mathsf { m A } current fows through the body whenaperson touchesa23oVenergised conductor underdry conditions.
Selection
Residual current sensitivity
| Protectionfrom | Residential | Non-residential | Sensitivity |
| Electricshocksbydirectcontact | |||
| Muandatoryprotectionforallsocket Mandatoryprotectionforallelectrical equipmentinbathroom Recommended for lighting circuits | Mandatortprotection for al Mandatoryprotection forall equipementlocated Close to water points | 30 m for alaplications whererequiredby the standard (e.g.: jacuzzi, swimming pools,etc.) | |
| Fireignited by leakage current | |||
| Recommendedin odbuidines | Mandatory inallocationsunder moisture,chemical agents. | 300mA | |
| Electricshockbyindirectcontact | |||
| 丝 | All circuits in case of "TT" earthing system | All circuits in case of "TT" earthing system | 100mA or300mA |
YRCB-63LBRCD SERIES Residual CurrentDevice
Advantages
The YRCB-63LB residual current device provide: Protection of personsagainst electric shock bydirect contact(y 30mA) ⊚ Protection of persons against electric shock by indirect contact(u 100mA) Protection of installations against the risk of fire ( 3 0 0 \mathsf { m A } or500mA)
Technical Data
| Main-Single phase | |
| Productorcomponenttype | Residualcurrent |
| Deviceapplication | Distribution |
| Polesdescription | 1P+N/2P |
| Number of protected poles | 2 |
| Network type | AC,A |
| Rated residual operating current In(mA) | 10,30,100,, |
| Ratedfrequency | 50/60Hz |
| Rated aimpulsevoithstand voltage (uimp) | 6kV |
| Retadconditional residualshort-circuitcurrentIC | 6kA |
| Main-Triplephase | |
| Productorcomponenttype | Residual current |
| Device application | Distribution |
| Polesdescription | 3P+N/4P |
| Numberof protected poles | 4 |
| Network type | AC,A |
| Ratedresidual operatingcurrentIn(mA) | 10,30,100,0,5 |
| Ratedfrequency | 50/60Hz |
| Rated aimpulse voithstand voltage (uimp) | 6kV |
| Retadconditionalresidualshort-circuitcurrentI&C | 6kA |
| Complementary | |
| Rated operational voltage Ue | 110V/230V/240VACSinglePhase; 385V/400VACTriplePhase |
| Control type | Toggle |
| Local signalling | ON/OFFindication |
| Mounting mode | Clip-on |
| Mounting support | DIN rail35mm |
| Colour | Grey |
| Electro-mechanical endurance | ≥20,000cyles |
| Environment | |
| Standards | IEC 61009-1,EC61008-1,AS/NZS61008-1 |
| IPdegreeofprotection | IP40 for modularenclosure conforming to IEC 60529 IP20conforming to IEC 60529 |
| Operatingaltitude | 2000m |
| Ambientair temperatureforoperation | -5℃to+60°℃ |
| Ambientairtemperatureforstorage | -40°℃to+85°℃ |
| Connection | |||
| Rating | Tightening torque | Coppercables | |
| Rigid | Flexible or ferrule | ||
| Cataloguenumbers | |||||
| YRCB-63LBRCCB Wiringdiagram | |||||
| TypeProduct AM | Widthin9mmmodule:4 | ||||
| Auxiliaries | N | ||||
| 2P | Sensitivity 10mA 30mA 100mA 300mA 500mA | ||||
| Rating 16A | 25A 40A | 63A | 80A 100A | ||
| Voltagerating (Ue) | 2P 110-240V | ||||
| Operatingfrequency | N 2 50/60Hz | ||||
Dimensions
Unit: mm
YRCB-63LBRCD SERIES Residual Current Device(Type B)
Advantages
Protection in the event of a continuous earth fault current on networks generated by:
Controllersandvariablespeeddrives
Batterychargersand inverters,suchasusedinphotovoltaicapplication
⊚ Backed-up powersupplies
TechnicalData
| Main | |
| Productorcomponenttype | Residual current circuitbreaker(RCCB) |
| Device application | Electrical vehicle charger,Solar energy system |
| Polesdescription | 2P/4P |
| Network type | AC,Pulsting DC,Smooth DC |
| Earth-leakagesensitivity | 30mA,100mA-300mA |
| Earth-leakage protection class | TypeB |
| Device locationinsystem | Groupincomer |
| Network frequency | 50/60Hz |
| Ratedbreakingandmakingcapacity | Im630A Idm630A |
| Ratedconditional short-circuit current | 6kA |
| Rated insulationvoltage Ui | 2P250V/4P400V |
| Rated impulse withstand voltage Uimp | 6kA |
| Contact position indicator | Yes |
| Control type | Toggle |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 15000cycles |
| Tightening torque | 3.5N.m (top or bottom) |
| Environment | |
| Standards | EN61008-1,EC618-1,EC/EN624 |
| IPdegree of protection | IP40 for modular enclosure conforming to IEC 60529 IP20conformingto IEC60529 |
| Operatingaltitude | 2000m |
| Ambient air temperature for operation | -5Cto+60°℃ |
| Ambientairtemperatureforstorage | -40°℃to+85°℃ |
Dimensions
YRL7-63LE6KA RCBO SERIES YRL7-63LERCBOSERIES Residual Current Circuit Breaker With Overcurrent Protection
YRO
Application
RCBOis mainlyusedinAC50Hz(60Hz),ratedvoltage230/400V,ratedcurrent6Ato63Alowvoltage terminaldistribution system.RCBO is equal with M C B + R C D function;It is used for electric shock protection and human indirect contact protection,electricequipmentprotectionwhenhumanbodytouchingelectricityorelectricnetworkleakcurentexceeds stipulatedvalue,andoverloadandshortcircuitprotection;Itcanalsobeanon-frequencyoperatorinthecircuit,wildlyused intheresidentialand commercial district.Itcomplieswithstandard ofIEC61009-1.
Technical Data
| Electrical Features | |
| Mode | Electronic/Electromagnetic |
| Type | A/AC/B |
| Tripping curve | BCD |
| Pole No. | 2P/4P1P+N3P+N |
| Ratedcurrent | 6A,10A,16A,2A,25A,2A,4A,5A,6, |
| Rated voltage | 230/400V~ |
| Ratedfrequency | 50/60Hz |
| Rated residual operating current(I△n) | 30mA,100mA,00mA |
| Residualoperatingcurrentrange | 0.5I△n~I△n |
| Rated conditional short-circuit current(Inc) | 6000A/10000A |
| Energylimiting | class3 |
| Electrical and Mechanical life | 20000 |
| Installation | |
| Faultcurrentindicatorwindow | Yes |
| Protectiondegree | IP20 |
| Ambienttemperature | -5~+40Canditsaverage overaperiodof24hdoes notexceed+35℃ |
| Storage temperature | -25~+70C |
| Terminalconnectiontype | Cable/U-type busbar/Pin-typebusbar |
| Terminal size top forcable | 25mm² |
| Tightening torque | 2.5N.m |
| Mounting | On DIN railFN 60715 (35mm) |
| Connection | Topandbottom |
| OverloadCurrentProtectionCharacteristics | ||||||
| TestProcedure | Type | TestCurrent | InitialState | TrippingorNon-tripping Time Limit | ExpectedResult | Remark |
| A | BCD | 1.13In | Cold | t≤1h | no tripping | |
| B | BCD | 1.45In | AftertestA | t≤1h | tripping | Thecurrent steadilyrifesto the valuewithin5s |
| C | BCD | 2.55In | Cold | 1s| tripping | | |
| D | B | 3In | Cold | Turn on the switcntioclose thecurrent | ||
| C | 5In | t≤0.1s | notripping | |||
| D | 10In | |||||
| E | B | 5In | Cold | t≤0.1s | tripping | Turn on the switchtoclose the current |
| C | 10In | |||||
| D | 20In | |||||
| ResidualCurrentOperatingBreakingTime | ||||||||
| Type | In/A | I△n/A | Residual Current(I△)IsCorrespondingToTheFollowing Breaking Time(S) | |||||
| ACType | Anyvalue | Anyvalue | In | 2In | 5In | 5A,10A,20A,50A,100A,200A,50A | ||
| ACType | >0.01 | 1.4In | 2.8In | 7In | ||||
| 0.3 | 0.15 | 0.04 | 0.04 Maxbreakingtime | |||||
| The general type RCBO whose currentI△n is 0.03mA or less can use 0.25A instead of 5I△n. | ||||||||
Wiring diagram
中书电书 点H22468
Dimensions
Unit: mm
YRL7-63LE 10KA RCBO SERIES Residual Current CircuitBreaker With OvercurrentProtection
Application
The YRL7-63LE series small leakage circuit breaker is suitable for distribution lines with arated frequency of 5 0 H z arated working voltageofAC240/AC40oV,andaratedworkingcurrentof63Aandbelow.Whenaperson iselectrocutedorthe leakagecurentofthepowergridexceedsthespecifiedvalue,theleakagecircuitbreakercanquicklycutofthefaultypower supplyinaveryshort time,protecting the safety of personand electrical equipment.
YRL7-63LE series smallresidualcurrnt circuit breaker isadvanced in structure,reliable in performance and compact in size.ltsshellismadeofimpactresistantandhighflameretardant materials.TheYRL7-63LEseriessmalleakagecircuit breakerhasoverload,shortcircuit,andleakageprotectionfunctions,mainlyusedforoverload,shortcircuit,ndleakage protectionoflighting,distributionlines,ndequipmentinofcebuildings,residentialbuildings,ndsimilarbuildings.lan also be used forinfrequent switching and starting of lines under normal circumstances.
TechnicalData
| Electrical Features | |
| Ratedframecurrent | 63A |
| Compliantwith standards | GB/T16917.1,IEC 61009-1 |
| RatedcurrentA | 1A,2A,3A,4A,6A,10A,16A,20A,25A,32A,40A,50A,63A |
| Rated voltage | AC240/AC400V(1P+N),AC400V(3P+N) |
| Tripping curve | B(3-5In),C(5-10ln),D(10-20ln) |
| Number of poles | 1P+N,3P+N |
| Unipolarwidth | 18mm |
| Rated residual operating current | 10,30,100,300mA |
| Ui/Rated insulationvoltage Ui | 500V |
| Rated impulse withstand voltage Uimp | 4kV |
| Ratedbreakingcapacity | 10kA |
| Mechanical life | 20000 |
| Electrical life | 4000 |
Workingandinstallationconditions
⊚ Environmentaltemperature(dailyaverage temperature < 3 5 ^ { \circ } C ) : - 5 ^ { \circ } C ~ + 4 0 ^ { \circ } C
Storage temperature: * 2 5 ^ { \circ } C ~ + 7 0 ^ { \circ } C (20
⊚ Protection level:IP20
Wiring capacity: 2 5mm ^ { 2 } (204号
⊚ Wiring torque:2.5N.m
Installation method:DIN rail installation EN60715 3 5mm )
⊚ Wiringmethod:bothupperand lower incoming linesareacceptable
Pollution level: 2
Producttrippingcharacteristics
| Rated current(A) | Overloadtrippingcharacteristics | Instantaneous chartrteristics(A) | Ratedresidual Action curenttime H | |
| 1.13InmeHecdnontripping | 1.45lne H(dt triaeing | |||
| In≤63 | 1 | 1 | B(3-5In),C(5-10In) D(10-20ln) | 10,30,10,m |
| In>63 | 2 | 2 | ||
Releasecurvediagram
爪
5
21
0.5 20 70 50 0C Rated current multiple→
an/nag g 印
0.5
8.802
0.001
1.5 245357 10 2030 7050100 200 Rated current multiple→
Dimensions
YRL7-125LE 6kA RCBO SERIES Residual Current CircuitBreaker With OvercurrentProtection
Application
TheYRL7-125LEseriessmalleakagecircuitbreakerissuitablefordistributionlineswitharatedfrequencyof5OHz,arated working voltageofAC240/AC400V,andaratedworking curentof125Aand below.Whenaperson iselectrocutedorthe leakagecurrentofthepowergridexceedsthespecifiedvalue,theleakagecircuitbreakercanquicklycutoffthefaultypower supplyinavery short time,protecting thesafety ofpersonandelectrical equipment.
YRL7-125LEseries smallresidualcurrntcircuit breakerisadvancedinstructure,reliableinperformanceand compact in size.ltsshellismadeofimpactresistantandhighflameretardantmaterials.TheYRL7-125LEseriessmalleakagecircuit breakerhasoverload,shortcircuit,andleakageprotectionfunctions,mainlyusedforoverload,shortcircuit,andleakage protectionoflightingdistributionlines,ndequpmentinofcebuldings,residentialbldingsndsimilarbuildings.ltan also be used for infrequent switching and starting oflines under normal circumstances.
TechnicalData
| Electrical Features | |
| Ratedframecurrent | 125A |
| Compliantwith standards | GB/T16917.1,IEC 61009-1 |
| RatedcurrentA | 63A-125A |
| Rated voltage | AC240/AC400V(1P+N),AC400V(3P+N) |
| Tripping curve | B(3-5In),C(5-10In),D(10-20ln) |
| Number of poles | 1P+N,3P+N |
| Unipolarwidth | 18mm |
| Rated residual operatingcurrent | 10,30,100,300mA |
| Ui/Rated insulationvoltage Ui | 500V |
| Rated impulse withstand voltage Uimp | 4kV |
| Ratedbreakingcapacity | 6kA |
| Mechanical life | 20000 |
| Electrical life | 4000 |
Workingandinstallationconditions
⊚ Environmental temperature(dailyaverage temperature < 3 5 ^ { \circ } C ) : - 5 ^ { \circ } C ~ + 4 0 ^ { \circ } C
Storage temperature: * 2 5 ^ { \circ } C ~ + 7 0 ^ { \circ } C (20
⊚ Protection level:IP20
Wiring capacity: 2 5mm ^ { 2 } (204号
⊚ Wiring torque:2.5N.m
Installation method:DIN rail installation EN60715( 3 5mm )
⊚ Wiringmethod:bothupperand lower incoming linesareacceptable
Pollution level: 2
Producttrippingcharacteristics
| Rated current(A) | Overloadtrippingcharacteristics | Instantaneous chartrteristics(A) | Ratedresidual Action curenttime H | |
| 1.13InmeHecdnontripping | 1.45lne (dt triaeing | |||
| In≤125 | 1 | 1 | B(3-5ln),C(5-10In) D(10-20ln) | 10,30,10,m |
| In>125 | 2 | 2 | ||
Releasecurvediagram
凯
5
2
0.5
15 2 2030 705010 200 Rated current multiple→
an/nag g 印
0.5
8.802
0.001
1.5 245357 10 2030 7050100 200 Rated current multiple→
Dimensions
AC Mold Case Circuit Breaker
YRM1 SERIES ACMold CaseCircuitBreaker
Application
TheYRM1seriesplasticshelltypecircuitbreaker(hereinafterreferredtoasacircuitbreaker)isoneofthenewtypeofcircuit breakersusedininternationaladvanceddesign,manufacturing technologydevelopmentanddevelopment.Itsrated insulationvoltageis1000V(YRM1-63is800V).AC50/60Hz,theratedoperatingvoltageof400/800Vandbelow,andthe ratedworkingcurentto1250Aisusedtomakenon-frequentconversionandthemotordoesnotfrequentlystart.Thecircuit breakerhasthefunctionofoverloading,shortcircuitandvoltageprotection,andcanprotectthelinesandpowerequipment frombeing damaged.
ThecircuitbreakerisdividedintoS-shaped(standardtype)andH(highdivision)accordingtotheheightofitsratedlimit short-circuitcapacity(CU).isbrokencircuitsthearacteristicsofsalllume,ighseparationapacityortrc distance,short vibration resistance and othercharacteristics.Itisan idealproduct usedin land and ships.
Thisbrokencircuitcaneinstalledvertically(ie,vertical),orcaneinstalledhorizontally(ie,horizontalistalation).
This brokencircuitcannotbepouredintothewire,thatis,only1,3,and5canbeconnectedtothesourceline,andthe negative carrierof2,4,and6 canbe connected.
⊚ This brokencircuit hasanisolation function.Thesymbolis marked:e
⊚ This product meets IEC60947-2,GB14048.2 standards.
Normaluseenvironment
The altitude is 2 0 0 0 { m } andbelow;
The temperature of the surrounding medium is not higher than + 4 0 ^ { \circ } C (the ship's product is + 4 5 ^ { \circ } \mathsf { C } ) 号 and not less than - 5 ^ { \circ } C ; (204号
Pollution level 3;
⊚ Can tolerate the effects of humid air;
⊚ Can tolerate the effects of salt fog and oily mist;
Can tolerate the impact of mold;
Themaximum tilt is ± 2 2 . 5 ^ { \circ } :
⊚ It canwork reliablywhen the ship is vibrated normally;
⊚ In the case of earthquake (4G),it can work reliably;
\odot Ina medium without explosive hazards,the medium is notenough to corrode the metal and the excessive gas and conductive dust;
There is no place for rain and snow.
Deepdeduction methodandaccessoriescode
□Alarm ■Auxiliary Split deck 0 Walled voltage offerler→Direction
Handle Installationon the left Installationon the right
Note:
| Rated current of the deduction (A) | Environmentaltemperatureofthermagneticdeduction (landforland+40℃/ship+45℃) | Electromagnetic deedractioncurrent(A) | |
| 1.05ln (Cold State) Noactiontime(h) | 1.30in (Hot State) Action Time(H) | ||
| In≤63 | ≥1 | 10ln±20% | |
| In>63 | ≥2 | ||
630| ≥2 | 10ln±20% 5ln±20% | | |
Table3:Riteraction characteristics (for electric motor protection)
| Ratedcurrentof thededuction(A) | Environmentaltemperatureofthermagneticdeduction (landforland+40℃/ship+45℃) | Electromagnetic deedraction current(A) | |||
| 1.0ln(Cold State) Noactiontime(h) | 1.20ln (hot) actiontime(H) | 1.50ln (hot) actiontime(H) | 7.2In (Cold) Noactiontime(h) | ||
| In≤225 | ≥2 | ≥2 | 4s| 12In±20% | | |
225| 6s | | ||||
Technical Data
| Model | curtedt | vottede | Fiviane | ||||||
| YRM1-63L | 63 | (6)、10、16 20、25、32 | 800 | 35 | / | 25 | / | ||
| YRM1-63M | 50 | 35 | / | ||||||
| YRM1-63H | 85 | / | 65 | ||||||
| YRM1-125L | 125 | 10、16、20 25、3、0 | 800 | 35 | / | 25 35 | / | ≤50 | |
| YRM1-125M | 50 85 | 25 / | |||||||
| YRM1-125H | |||||||||
| YRM1-250L | 250 | 100、125 10、200 | 1000 | 35 | /25 / | 25 | / 15 | ||
| YRM1-250M | 65 | ||||||||
| YRM1-250H | 100 | / | |||||||
| YRM1-400L | 400 | 225、250 315、350 400 | 1000 | 50 | 35 / | 35 50 | / 20 | ||
| YRM1-400M | 65 | ||||||||
| YRM1-400H | 100 | 65 | / | ||||||
| YRM1-630L | 400、500 | 1000 | 50 65 | 35 / | 35 50 | / | |||
| YRM1-630M | 20 / | ||||||||
| YRM1-630H | / | / 35 | / | ||||||
| YRM1-800L | 800 | 630、700 | 1000 | 50 75 | 35 / | 50 | 20 | ||
| YRM1-800M YRM1-800H | 100 | / | 65 | / | |||||
| 50 | 35 | 35 | / | ||||||
| YRM1-1250L YRM1-1250M | 1250 | 800、1000 | 1000 | 85 | / | 65 | 25 | ||
| YRM1-1250H | 100 | / | 75 | / | |||||
| Temperature | +40℃C | +45℃ (shipforship+45℃C) (ship for ship+50℃) | +50C (ship forship+55) | +55℃C (shipforship+60℃) | +60℃C (ship for ship+65℃) |
| Coefficient Model | Reducing coefficient | Reducing coefficient | Reducing coefficient | Reducing coefficient | Reducing coefficient |
| YRM1-63(L、M、H) | 1In | 0.94In | 0.88In | 0.80In | 0.72In |
| YRM1-100(L、M、H) | 1In | 0.94In | 0.89In | 0.84In | 0.76In |
| YRM1-225(L、M、H) | 1In | 0.94In | 0.93In | 0.90In | 0.86In |
| YRM1-250(L、M、H) | 1In | 0.94In | 0.91In | 0.87In | 0.82In |
| YRM1-400(L、M、H) | 1In | 0.94In | 0.87In | 0.81In | 0.73In |
| YRM1-630(L、M、H) | 1In | 0.94In | 0.88In | 0.83In | 0.76In |
| YRM1-800(L、M、H) | 1In | 0.94In | 0.83In | 0.79In | 0.76In |
| YRM1-1250(L、M、H) | 1In | 0.94In | 0.8In | 0.7In | 0.7In |
Outlineandinstallation dimensions
YRM1-63
Unit:mm
Outline and installation dimensions
YRM1-125
Unit:mm
Front wiring
Outlineandinstallation dimensions
YRM1-250
Unit: mm
Front wiring
Outline and installation dimensions
Outline and installation dimensions
Outline and installation dimensions
Insertion wiring
Outline and installation dimensions
| YRM1-1250 Unit:mm |
Surge Protective Device
YRSP-A1 SERIES
Type1Lightning Surge Protective Device
Surge Protective Device YRO Surge Protective Device YRO YRO YRO YRO
EN61643-11IEC61643-11 Uc(50-60Hz)385VAC limp(10/350us)25kA IiR 国 YRSP-A1 IP20 2 EN61643-11IEC61643-11 In (820 μ s). lmp(10/350μs)25kA Uo(50-60Hz) Up: 国 YRSP-A1 IP20 Surge Protective Device Uo(50-60Hz)385VAC In (8/20 μ s): lmp(10/350μs)25kA u YRSP-A1 <18AV 25kA Surge Protective Device Uo(50-60Hz)385VAC In(820 μs). limp(10/350 μ s): u YRSP-A1 ≤1.8/ 25kA 25kA Surge Protective Device Uc(50-60Hz)385VAC mp(10350μs)25kA In (8/20 μ s). up YRSP-A1 I≤18V 25kA EN61643-11 IEC61643-11 PE EN61643-11IEC61643-11 EN61643-11IEC61643-11 PE
Overview
YRSP-A1seriesisthemostrobustrangeofType1/Classlightningcurrentarresters,abletodischargeenergy(urrent)from adirectlightningstrike(10/350)onanexternalightningprotectionsystem(LPS)oroverheadsupplies,inaccordancewith EN/IEC61643-11.DINrailmonoblocformat.
Suitableasafirststepofprotectioninincoming powersupplypanelsandinareasof highatmosphericexposure ⊚ Discharges impulse currents with a 10/350 us waveform:50 kA per phase.
⊚ Exclusive devices forTNS earthing systems.
⊚ Exclusive devices which are compatible with Power Line Communication networks.
⊚ Biconnect-two types of terminal:for rigid orflexible cableand for fork type comb busbar.
⊚ Available with optional remote signalling.
Application
AC/DC distribution
⊚ Powersupplies
⊚ Industrialautomation
⊚ Telecommunications
⊚ Motorcontrolssystems
⊚ PLC applications
⊚ Powertransferequipment
HVAC applications
⊚ ACdrives
⊚ UPS systems
⊚ Security systems
IT/Data centers
⊚ Medical equipment
Features/Benefits
Easy installation orretrofit
⊚ Din-rail mountable
⊚ Fail-safe/self-protected design
Remote indicator(optional) with2 pin C/NCcontact
\odot Degree of Protection IP20
Technical Parameters
| Type | YRSP-A1 |
| Technical Data | |
| Power supply system | TNS 230/400V(50/60Hz) |
| Nominallinevoltage (Un) | 255V |
| Maximum continuous voltage (Uc) (L-N) | |
| SPDto EN61643-11 | Type1 |
| SPD to IEC 61643-11 Lightning impulsecurrent(10/350us) (limp) | classI 25kA |
| Nominal discharge current (8/20us) (In) | 25kA |
| ≤2.0kV | |
| Voltageprotectionlevel (Up) | |
| Response time (tA) | |
| OperatingState/FaultIndication Degree of protection | no IP20 |
| Insulatingmaterial/flammabilityclass | PA66,UL94V-0 |
| -40℃~+80℃ | |
| Temperature range Altitude | 13123ft [4000m] |
| Conductor CrossSection (max) | 35mm²(Solid)/25mm²(Flexible) |
| Remote Contacts(RC) | Optional |
| Format | Monobloc |
| Maximun back-upfuse | 315AgL |
| Formounting on | DIN rail 35mm |
| Placeof installation | Indoor installation |
Dimensions& InternalConfiguration
YRSP-A2SERIES
Type2Surge Protective Device
Technical Parameters
| TechncarData | ||||||||
| Location of Use | Sub-Distribution Boards TN-S,TN-C, TT (only L-N) | |||||||
| NetworkSystems | ||||||||
| Mode of Protection | L-PE,N-PE(only TN-S),L-PEN,L-N | |||||||
| Surge Ratings | In=20kA(8/20 μs) | |||||||
| IEC/EN Category Protective Elements | ClassII/Type2/Type1CA | |||||||
| Housing | High EnergyMOV Pluggable Design | |||||||
| Compliance | IEC 61643-11:2011 | |||||||
| EN 61643-11:2012 | ||||||||
| IEC ELECTRICAL | ||||||||
| 75 | 150 | |||||||
| YRSP-A2 NominalACVoltage(50/60Hz) | 120V | 275 | 385 | 420 | 480 | |||
| Maximum Continuous Operating Voltage (AC) | U/Un | 60V 75V 150V | 230V | 230V | 400V | 480V | ||
| Uc | 20kA | 275V | 385V | 420V | 480V | |||
| Nominal DischargeCurrent(8/20 μs) | 20kA 40kA | 20kA | 20kA | 20kA | 20kA | |||
| Maximum Discharge Current (8/20 μs) | Imax | 40kA 1000V | 40kA 1500V | 40kA 1800V | 40kA 1800V | 40kA 2200V | ||
| VoltageProtectionLevel | Up 700V | |||||||
| Residual Current at Uc | lPE | |||||||
| Response Time tA | ||||||||
| Back-Up Fuse (max) | 125AgL/gG | |||||||
| Short-Circuit Current Rating (AC) | ISCCR 25kA | |||||||
| TOV Withstand 5s UT | 90V 180V | 335V | 335V | 580V | ||||
| UT | 115V | 230V 440V | 440V 765V | |||||
| TOV120min | SafeFail | |||||||
| mode Numberof Ports | Withstand Withstand SafeFail 1 | SafeFail SafeFail | ||||||
| Mechanical&Environmental | |
| Operating Temperature Range | -40°Fto+158°F[-40℃to+70℃] T |
| Permissible Operating Humidity | RH 55%..95% |
| Atmospheric pressure and altitude | 80k Pa ...106kPa/-500 m...2000m |
| TerminalScrewTorque | 39.9 Ibf-in [4.5Nm] Mmax |
| Conductor Cross Section (max) | 5AWG (Solid,Stranded)/5AWG (Flexible) |
| 16mm²(Solid,Stranded)/16mm²(Flexible) | |
| Mounting | 35mmDINRail,EN60715 |
| Degree of Protection | IP 20 (built-in) |
| Housing Material | Thermoplastic:Extinguishing DegreeUL94V-0 |
| Thermal Protection | Yes |
| OperatingState/FaultIndication | Greenok/Reddefect |
| Remote Contacts (RC) | Optional |
| RCSwitching Capacity | AC:250V/0.5A;DC:250V/0.1A;125V/0.2A;75V/0.5A |
| RC Conductor Cross Section (max) | 16 AWG (Solid) /1.5 mm²(Solid) |
Internal Configuration
Dimensions & Packaging
| YRSP-A2 | 275 | 385 | 420 | 480 |
| SingleUnitDIN43880Dimension | 1CTN | |||
| Packaging Dimensions(HxWxL) | [520×220×300mm] | |||
| Pole | 1Pole | 2Pole | 3Pole | 4Pole |
| MinimumOrderQuantity | 144Units | 72Units | 48Units | 36Units |
Connection Diagram