3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.4
030 3A 320 32 1C/O
040 4A 400 40A 4 2NO
500 5 1N+1C/O
Product typ A B
CPD161-2 42 54
CPD161-3 60 72
CPD161-4 96 108
1
2
3
4
5
6
7
8
Ex-d built-in components - MCB modules
Dimension drawing (mm) / Connection diagram
AGP17 Stainless Steel Panelboard with Painting
3
2.3.5 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Certifications and Compliances
Marking accd. to 2014/34/EU D II 2 G Ex de IIB/IIC Gb
Marking accd. to IECEx Ex de IIB/IIC Gb
Functional temperature -20rC up to +70rC
Application temperature1) -20rC up to +55rC (IIC / IIB based on AGP17)
Limits of service temperature -20rC up to +110rC (IIC / IIB)
Component degree of protection accd. EN 60529 IP20
Storage temperature -20rC up to +55rC in original packing
Electrical Ratings
Safe Isolation to EN 61140 between aux contacts and main contacts 500 VAC
between aux contacts 300 VAC
Rated impulse withstand voltage main contacts 8000 V
auxiliary contacts 6000 V
Rated operating voltage Ue 440 V
Rated switching capacity Icu 400/415/440V (50/60Hz) kA/cos 10 kA/0.25 or 25 kA
500VDC 10 kA
Rated current In main contact 20A,25A,32A,40A,63A,80A,100A,125A,160A,200A or 250A
aux. contact max. 5 A
Adjustable setting range Ir 0.8 to 1.0 x rated current In
Short current protection Ii = 10 x In
Utilization category to IEC/EN 60947-2 A
Making/breaking capacity at rated current up to 400 V AC1 & AC3
Connecting terminals main contact 1 x 4.0 mm² up to 1 x 185 mm²
Rated voltage aux. contact max. 500 V AC
Rated current aux contact AC15 Ie (up to 230 V) / DC13 Ie (up to 24 V) 4 A / 3 A
AC15 Ie (up to 400 V) / DC13 Ie (up to 60 V) 2 A / 1.2 A
AC15 Ie (up to 500 V) / DC13 Ie (up to 110 V) 1 A / 0.8 A
DC13 Ie (up to 220 V) 0.3 A
Connecting terminals aux./ Signal contact 1.0 mm2
up to 4.0 mm2
fine stranded
Total opening delay on short circuit < 10 ms
$dditional 6pecifications
Weight 10.5 kg - 4-pole / 10 kg - 3-pole
Enclosure material Polyamide
Built-in position Vertical and rotated 90 deg in all directions
Release system Thermomagnetic release
1) The limits of the operating temperature range and the max. permissible temperature rise of the components (functional temperature) have to be taken into account.
MCCB 20A to 250A
GHG 6277
Ex-d built-in components - MCCB modules
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.6
Ex-d built-in components - MCB modules
MCCB ordering logic
Dimension drawing (mm) / Connection diagram
AGP17 EXPLOSION-PROOF DISTRIBUTION BOARDS 5
1/23/45/6
X 160 12.5
180 6.4
MCCB Ordering Logic
7726GHG 0 10 0R 1 3 2
Product
Group guration Accessories Version # of poles shortcircuit
current
Rated
current
GHG6277 0 MCCB only
01 Shunt trip 24V AC/DC + early make 1NO
00 MCCB only R0 E-series
(standard)
1 3 Pole 3 IEC 10 kA@ 440V
2 63 A
1 MCCB + 1NO
02 Shunt trip 110V-130V AC/DC + early make 1NO
2 4 Pole 4 IEC 25 kA@ 440V AC
3 80 A
2 MCCB + 1NC
03 Shunt trip 208V-250V AC/DC + early make 1NO
R1 A-series
(@ 10 kAonly)
R2 E-series
(Low current)
10kA@500V DC
4 100 A
3 MCCB + trip
04 Shunt trip 380V-440VAC/DC + early make 1NO
5 125 A
1 20 A1)
2 25 A1)
3 32 A1)
4 40 A1)
indicator 1NO
05 Uv release 24V 50/60Hz + early make 1NO
6 160 A
4 MCCB + 1NO/1NC
06 Uv release 110V-130V 50/60Hz + early make 1NO
7 200 A
+ trip indicator 1NC
07 Uv release 208V-240V 50/60Hz + early make 1NO
9 250 A
5 MCCB + 2NO 5
6 MCCB + 2NC 6 08 Uv release 380V-440V 50/60Hz + early make 1NO
7 MCCB + 2NO 09 Uv release 480V-525V 50/60Hz + early make 1NO
+ trip indicator 1NO 10 Shunt trip 24V AC/DC
8 MCCB + 2NC 11 Shunt trip 110V-130V AC/DC
+ trip indicator 1NO 12 Shunt trip 208V-250V AC/DC
9 MCCB + 1NO + 1NC 13 Shunt trip 380V-440VAC/DC
+ trip indicator 1NO 14 Uv release 24V 50/60Hz
15 Uv release 110V-130V 50/60Hz
16 Uv release 208V-240V 50/60Hz
17 Uv release 380V-440V 50/60Hz
18 Uv release 480V-525V 50/60Hz
19 Early make aux. switch 2NO
20 Uv release 24V DC
1) Available for R2 E-series only
N 1/23/45/6
N 2/14/36/5
X 160 12.5
382 X 365
203 205.3
180 6.4
(N)
(N) 1 3 5
2 4 6
X
X
X
X
A/E series
MCCB Ordering Logic
7726GHG 3 2
Product
guration Accessories Version # of poles shortcircuit
current
Rated
current
0 MCCB only
01 Shunt trip 24V AC/DC + early make 1NO
00 MCCB only E-series
(standard)
IEC 10 kA@ 440V
2 63 A
MCCB + 1NO
02 Shunt trip 110V-130V AC/DC + early make 1NO
3 80 A
2 MCCB + 1NC
03 Shunt trip 208V-250V AC/DC + early make 1NO
A-series
MCCB + trip
04 Shunt trip 380V-440VAC/DC + early make 1NO
5 125 A
1 20 A
2 25 A
3 32 A
4 40 A
indicator 1NO
05 Uv release 24V 50/60Hz + early make 1NO
4 MCCB + 1NO/1NC
06 Uv release 110V-130V 50/60Hz + early make 1NO
+ trip indicator 1NC
07 Uv release 208V-240V 50/60Hz + early make 1NO
MCCB + 2NO 5
6 MCCB + 2NC 6 08 Uv release 380V-440V 50/60Hz + early make 1NO
MCCB + 2NO 09 Uv release 480V-525V 50/60Hz + early make 1NO
+ trip indicator 1NO 10 Shunt trip 24V AC/DC
MCCB + 2NC 11 Shunt trip 110V-130V AC/DC
+ trip indicator 1NO 12 Shunt trip 208V-250V AC/DC
13 Shunt trip 380V-440VAC/DC
14 Uv release 24V 50/60Hz
15 Uv release 110V-130V 50/60Hz
16 Uv release 208V-240V 50/60Hz
17 Uv release 380V-440V 50/60Hz
Dimension drawing (mm) / Connection diagram
3
2.3.7 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Certifications and Compliances
Marking accd. to ATEX/IECEx Ex db eb IIC Gb
Application temperature -25rC up to +55rC / -20rC up to +55rC
Electrical Ratings
Rated voltage Main contact max. 415 V AC
Auxiliary contact max. 250 V AC
Rated current Main contact 16A to 63A
Auxiliary contact max. 5 A
Rated residual operating current 30mA, 100mA or 300mA
Back-up fuse depend on rated current up to 100 A
Connection terminals Main contact 25 mm2
Auxiliary contact 2.5 mm2
$dditional 6pecifications
Weight 0.74 kg size 1
1.13 kg size 2
1.49 kg size 3
Enclosure material Reinforced Όame-retardant nylon
Enclosure colour black
Options Aux. contact; signal contact
Padlocking capability Padlockable at oΊ postion
RCD 30mA to 300mA (16A/25A/40A/63A)
RCD ordering logic
Dimension drawing (mm) / Connection diagram
Size 1 Size 2 Size 3
Ex-d built-in components - RCD modules
Product
Group Enclosure size Internal components code Internal RCD Internal industrial
RCD size
Rated
current
Rated residual
operating current
Aux.
contact
Signal
contact Tamb
CPD161 2 Size 1
3 Size 2
4 Size 3
Enclosure Size 1
Enclosure Size 2
Enclosure Size 3
2 RCD
2P
2P+ Aux. contact(1CO)
2P+ Signal contact (1CO)
4P
4P+ Aux. contact(1CO)
4P+ Signal contact (1CO)
1 Eaton / PFIM / 2P or 4P /
(230V/400V) / 50+z / 55˚C3)
2 Eaton / FRCmM-A / 2P or 4P /
(240V/415V) / 60+z / 40˚C
2 2Pole
4 4Pole
160 16A1)
250 25A
400 40A
630 63A
030 30mA
100 100mA2)
300 300mA2)
0 NA
1 1C/O
0 NA
1 1C/O
N -20˚C up to +55˚C
Blank -25˚C up to +55˚C
TN -20˚C up to +40˚C
T -25˚C up to +40˚C
1) FRCmM-A only
2) Not available for FRCmM-A 63A/2P and 63A/4P 3) This is max. permissible ambient temperature
&ontact (aton Ior other configuration
cations and Compliances
o ATEX/IECExt.dccagnikraM
Application temperature
Electrical Ratings
egatlovdetaR CAV415.xam
CAV052.xam
tnerrucdetaR
Am003roAm001,Am03
A001otputnerrucdetarnodneped
thgieW 1eziSgk47.0
1.13 kg Size 2
1.49 kg Size 3
ruolocerusolcnE kcalb
ytilibapacgnikcoldaP
RCD Ordering Logic
CPD 1 2 630 030 0
Product
ents
size Rated current Rated residual
operati gnal
contactor
CPD161 2Size1/2Pole 2
Size2/3Pol
Size3/4Pole
Size 1 Size 2
Product type A B
CPD161-2 42 54
CPD161-3 60 72
CPD161-4 96 108
Dimension drawing (mm) / Connection diagram
1
2
3
4
5
6
7
8
AC SC
RCD 30mA to 300mA (16A/25A/40A/63A)
Internal industrial
RCD products series
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.8
Size 1
RCBO 6A to 63A (30A/300mA)
cations and Compliances
o ATEX/IECExt.dccagnikraM
Application temperature
Electrical Ratings
egatlovdetaR
tnerrucdetaR
A5.xam
esahp3/2yticapacgnihctiwsdetaR
esufpu-kcaB
slanimretnoitcennoC
mm5.2
thgieW 1ezisgk47.0
1.13 kg size 2
ruolocerusolcnE kcalb
snoitpO tcatnoclangis;tcatnoc.xuA
Product type A B
CPD161-2 42 54
CPD161-3 60 72
CPD161-4 96 108
1
2
3N
4N
1+PN 2P
1
2
3
4
Certifications and Compliances
Marking accd. to ATEX/IECEx Ex db eb IIC Gb
Application temperature -25rC up to +55rC / -20rC up to +55rC
Electrical Ratings
Rated voltage Main contact max. 400 V AC
Auxiliary contact max. 250 V AC
Rated current Main contact 6A to 63A
Auxiliary contact max. 5 A
Rated switching capacity 2/3 phase 10 kA
Back-up fuse depend on rated current up to 100 A
Connection terminals Main contact 25 mm2
Auxiliary contact 2.5 mm2
$dditional 6pecifications
Weight 0.74 kg size 1, 1.13 kg size 2, 1.49 kg size 3
Enclosure material Reinforced Όame retardant nylon
Enclosure colour black
Options Aux. contact; signal contact
Padlocking capability Padlockable at oΊ postion
RCBO 6A to 63A (30A/300mA)
RCBO ordering logic
Dimension drawing (mm) / Connection diagram
Size 1 Size 2 Size 3
Ex-d built-in components - RCBO modules
Product
Group
Enclosure
size Internal components code Internal RCBO RCBO
size
Tripping
characteristic
Rated
current
Rated
switching
capacity
Rated
residual
operating
current
Aux.
contact
Signal
contact Tamb
CPD161 2 Size 1
3 Size 2
4 Size 3
Enclosure Size 1
Enclosure Size 2
Enclosure Size 3
3 RCBO
1P+N
2P
1P+N+Aux. contact(1CO)
1P+N+ Sig. contact(1CO or 2CO)
2P+ Aux. contact(1CO)
2P+ Sig. contact(1CO or 2CO)
2P+ Aux. contact(1CO) 1)
2P+ Sig. contact(1CO or 2CO) 1)
1 Eaton / PLD10 / 1P+N / 230V / 50+z / 10kA / 55˚C4) / Electronic
2 Eaton / PL10+PDB / 2P/400V / 50+z / 10kA / 55˚C / Electronic 2)
3 Eaton / P)L10 / 1P+N / 230V / 50+z / 10kA / 55˚C / Electromagnetic
4 Eaton / PL10+PBSM / 2P / 230V / 50+z / 10kA / 55˚C / Electromagnetic 2)
5 Eaton / )RBmM-B / 2P / 240V / 50+z or 60+z / 10kA / 40˚C
6 Eaton / )RBm6-B / 2P / 240V / 50+z / 6KA, only 32A or 40A / 40˚C
7 Eaton / )RBmM-C / 2P / 240V / 50+z / 60+z / 10kA / 40˚C
8 Eaton / )RBm6-C / 2P / 240V / 50+z / 6KA, only 32A or 40A / 40˚C
2 1Pole+N
4 2Pole
B B capacity
C C capacity
D D caoacity
060 6A
080 8A
100 10A
130 13A
160 16A
200 20A
250 25A
320 32A
400 40A
500 50A
630 63A
10 10kA
06 6kA
030 30mA
300 300mA
100 100mA3)
0 NA
1 1C/O
0 NA
1 1C/O
2 2C/O
N -20˚C up to +55˚C
Blank -25˚C up to +55˚C
TN -20˚C up to +40˚C
T -25˚C up to +40˚C
1) PL10+PDB or PL10+PBSM 2) Enclosure size 3, Utilize philosophy of MCB + RCCB connection in series for 2pole RCBO3) Not available for PLD10 & PFL10
4) This is max. permissible ambient temperature
&ontact (aton Ior other configuration
3
2.3.9 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Certifications and Compliances
Marking accd. to ATEX/IECEx Ex db eb IIC Gb
Application temperature -20rC up to +50rC
Electrical Ratings
Rated voltage Main contact max. 440V AC
Auxiliary contact max. 415V AC
Rated current Auxiliary contact max. 5 A
Main contact 6 A 9 A 12 A 16 A
Rated capacity AC-3 220/240V 1.5 kW 2.2 kW 3 kW 3 kW
accd. to EN 60947-4-1 380/415V 2.2 kW 4 kW 5.5 kW 7.5 kW
440V 3 kW 4 kW 5.5 kW 7.5 kW
Connection terminals Main contact 25 mm2
Auxiliary contact 2.5 mm2
$dditional 6pecifications
Weight 3 pole 1.13 kg size 2
Enclosure material Reinforced Όame retardant nylon
Enclosure colour black
Options Aux. contact
Motor contactors
Size 2
Ex-d built-in components - Motor contactors
Ex-d built-in components -
cations and Compliances
Application temperature 02- ˚C up to +50˚C
Electrical Ratings
slanimretnoitcennoC tcatnocniaM
tcatnocyrailixuA
thgieW 2ezisgk13.1
ruolocerusolcnE kcalb
snoitpO
Motor contactor Ordering logic
Product type A B
Dimension drawing (mm) / Connection diagram
1
2
3
4
5
6
A1
A2 14
13
CPD161-3 60 72
Main contact max. 440V AC
Auxiliary contact
Auxiliary contact max. 5A
Main contact 6 A 9 A 12 A 16 A
Rated capacity AC-3 220/240V 1.5 kW 2.2 kW 3 kW 3 kW
accd. to EN 60947-4-1 380/415V 2.2 kW 4 kW 5.5 kW 7.5 kW
3 kW 4 kW 5.5 kW 7.5 kW
113
7.5x5.5
166 177
A
B
Motor contactor ordering logic
Dimension drawing (mm) / Connection diagram
CPD161 -3 -6 1 -09 -AC230 -2 -1 N
Product
Group Enclosure size
Internal
components
code
Internal contactor Rated current Control voltage(A1-A2) Aux. contactor NO
number
Aux. contactor NC
number Tamb
CPD161 3 Size 2 6 Motor contactor 1 Schneider/Tesys
K series
06 6A AC024 AC24 V DC012 DC12 V 0 NA 0NA N -20˚C up to +50˚C
Blank -25˚C up to +50˚C 09 9A AC048 AC48 V DC024 DC24 V 1 1NO 1 1NC
12 12A AC110 AC110 V DC048 DC48 V 2 2NO 2 2NC
16 16A AC230 AC230 V DC060 DC60 V
AC240 AC230/240 V DC110 DC110 V
AC400 AC380/400 V DC220 DC220 V
AC440 AC440 V
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.10
Certifications and Compliances
Marking accd. to ATEX/IECEx Ex db eb IIC Gb
Application temperature -25rC up to +64rC / -20rC up to +64rC
Electrical Ratings
Rated voltage Main contact max. 415V AC
Auxiliary contact max. 415V AC
Rated current Auxiliary contact max. 5 A
Main contact 20 A
Rated capacity AC-1 220-240V 7.6 kW
accd. to EN 60947-4-1 380-415V 13.5 kW
Rated capacity AC-3 220 2.2 kW
accd. to EN 60947-4-1 230-240V 2.5 kW
380-415V 4 kW
Connection terminals Main contact 25 mm2
Auxiliary contact 2.5 mm2
$dditional 6pecifications
Weight 1.13 kg size 2
1.49 kg size 3
Enclosure material Reinforced Όame retardant nylon
Enclosure colour black
Installation contactors
Size 2
Ex-d built-in components - Installation contactors
Installation contactor ordering logic
Dimension drawing (mm) / Connection diagram
CPD161 -2 -5 1 2 -50 230 -3 1 0 1 N
Product
Group Enclosure size Internal
components code
Internal
installation contactors
Installation
contactor Pole
number
Rated
current
Control voltage
(Coil voltage)
Main NO
contacts
Main NC
contacts
Aux. NO
contacts
Aux. NC
contacts Tamb
CPD161 3 Size 2 5 Installation
contactor
1 Eaton/Z-SCH installation
contactor
2 2Pole 20 20A 02424V AC 0 0NO 0 0NC 0 0NO 0 0NC N -20˚C up to +64˚C
Blank -25˚C up to +64˚C 4 4Pole 230230V AC 11NO 1 1NC 1 1NO 1 1NC
2 2NO 2 2NC
3 3NO 3 3NC
4 4NO 4 4NC
Enclosure Size 2 20A rating
113
7.5x5.5
166 177
A
B
AGP17 EXPLOSION-PROOF DISTRIBUTION BOARDS 9
cations and Compliances
Application temperature -25˚C up to +64˚C / -20˚C up to +64˚C
Electrical Ratings
slanimretnoitcennoC tcatnocniaM
mm5.2
1.49 kg size 3
ruolocerusolcnE
Installation Contactor Ordering Logic
Product type A B
Dimension drawing (mm) / Connection diagram
1
2
A1
A2
3
4
7
8
5 31 43
32 44 6
CPD161-3 60 72
Rated voltage Main contact
Auxiliary contact
Rated current Auxiliary contact
accd. to IEC/EN 60947-4-1 380-415V
Rated capacity AC-3 220V
accd. to IEC/EN 60947-4-1 230-240V
380-415V
3
2.3.11 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Thermal relays
Size 2
Ex-d built-in components - Thermal relays
Thermal relay ordering logic
Dimension drawing (mm) / Connection diagram
Certifications and Compliances
Marking accd. to ATEX/IECEx Ex db eb IIC Gb
Application temperature -20rC up to + 40rC
Electrical Ratings
Rated voltage Main contact max. 600 V AC
Auxiliary contact max. 600 V AC
Rated current Main contact 12.5A
Auxiliary contact max. 5A
Connection terminals Main contact 25 mm2
Auxiliary contact 2.5 mm2
$dditional 6pecifications
Weight 3 pole 1.13 kg size 2
Enclosure material Reinforced Όame-retardant nylon
Enclosure colour black
Ex-d built-in components - Thermal Relays
cations and Compliances
Application temperature 02-
Electrical Ratings
tcatnocniaM
tcatnocyrailixuA
tcatnocniaM
tcatnocyrailixuA
slanimretnoitcennoC tcatnocniaM
thgieW
ruolocerusolcnE
161DPC 3 4 1 02 N
Product Group Enclosure size Internal components code Rated voltage
(production series)
Rated current Tamb (Triping current)
CPD161 3 Size 2 4Thermal relay 1 Eaton/XTOD/CC1Thermal relay 01 0.3~0.45A N -20˚C up to +40˚C
Blank -25˚C up to +40˚C 02 0.45~0.67A
03 0.67~1.0A
04 1.0~1.5A
05 1.4~2.1A
06 1.8~2.7A
07 2.4~3.6A
08 3.5~5.0A
09 4.0~6.0A
10 5.5~8.5A
11 8.5~12.5A
Dimension drawing (mm) / Connection diagram
CPD161-3 60 72
Thermal relay Ordering Logic
cations and Compliances
o ATEX/IECExt.dccagnikraM
Application temperature
Electrical Ratings
tcatnocniaM
tcatnocyrailixuA
tcatnocniaM
mm52 2
thgieW
161DPC 4 1 02
Internal compon Rated voltage
Raed current Tamb (Triping current)
01 3~0.45A
02 0.45~0.67A
03 0.67~1.0A
04 0~1.5A
05 4~2.1A
06 8~2.7A
07 4~3.6A
08 5~5.0A
09 0~6.0A
5~8
Size 2
Product type A B
Dimension drawing (mm) / Connection diagram
Thermal Relays
CPD161-3 60 72
97 95
2 4 6 98
1 3 5
96
Thermal relay Ordering Logic
113
7.5x5.5
166 177
A
B
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.12
Busbar system
Busbar
Certification and compliances
$7E; ,ECEx certificate SEV 21 ATEX 0558U / IECEx_NEP_21.0007U
Marking according to ATEX / IECEx Ex eb IIC Gb
Permissible ambient temperature -55˚C up to +55˚C
Electrical Ratings 250A
Rated voltage 690V
Rated current 250A
Rated short time current/1s 4kA
Rated short circuit current 35kA
Rated cross-section 60 mm²
Wire cross-section 1.5 mm² up to 185 mm²
Overall length of unit Up to 6300 mm
Electrical Ratings 315A
Rated voltage 690V
Rated current 315A
Rated short time current/1s 9kA
Rated short circuit current 47kA
Rated cross-section 120 mm²
Wire cross-section 1.5 mm² up to 185 mm²
Overall length of unit Up to 6300 mm
Ex-d built-in components - Busbar
3
2.3.13 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Dimensions of enclosures
Type Dimension
(H x W x D in mm)
Size 1 315 x 175 x 135
Size 2 315 x 315 x 135
Size 2 deep 315 x 315 x 210
Size 3 632 x 315 x 135
Size 3 deep 632 x 315 x 210
Size 4 949 x 315 x 135
Size 4 deep 949 x 315 x 210
Note: Enclosures can be connected on request .
316L enclosure with dimension for panelboard
175
315
135
315
632
135
210
Size 1 Size 2 & Size 2 deep
Size 2 Deep
Size 3 Deep
Size 4 Deep
Size 3 & Size 3 deep Size 4 & Size 4 deep
Dimensions in mm
Note: Enclosures can be connected for panel building on request.
315
210 315
315
135
135
315
315 210
949
135
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.14
Dimensions of enclosures
Type Dimension
(H x W x D in mm)
Size 1 271x134x136
Size 2 271x271x136
Size 2 deep 271x271x210
Size 3 544x271x136
Size 3 deep 544x271x210
Size 4 817x271x136
Note: Enclosures can be connected on request .
GRP enclosure with dimension for panelboard
Size 1 Size 2 & Size 2 deep
Note: Enclosures can be connected for panel building on request.
257
257
260 260
247
120
257
260 273 260
136
271
271
271
544
GHC7 Enclosure Size1(271x134x136)
0.5 Unit / Low cover
GHC7 Enclosure Size2(271x271x210)
1 Unit / High cover
271
134
GHC7 Enclosure
Size2(271x271x136) 1 Unit /
Low cover
136
136
136
271
817
210
210
Dimensions in mm
Size 3 Deep
Size 3 & Size 3 deep Size 4
Size 2 Deep
3
2.3.15 EATON’S CROUSE-HINDS SERIES PORTFOLIO
EC-type examination certificate PTB 99 ATEX 1044 / BVS 22 ATEX E 006
GB-certification of conformity CCC
,ECEx-certification of conformity IECEx BKI 07.0023 / IECEx BVS 22.0008
Marking acc. to ATEX II 2 G Ex de ia/ib m [ia/ib] IIC T4-T6 / II 2 D Ex tD A21 IP66/IP65 T80 °C, T95 °C
Marking acc. to IECEx Ex de ia/ib m >ia/ib@ T4ȏT6
Ex tD A21 IP66 T80˚C
Application temperature -20˚C a +40˚C
-55˚C a +55˚C (option)
Rated voltage 690V
Rated current 400A
Insulation class I
Terminal cross-section Up to 300mm2
Degree of protection IP66 acc. to EN 60529
Enclosure material Glass fibre reinforced polyester
Enclosure colour Black
Version Type MCB 2-pole Terminal cross-section Cable gland Weight Order No.
40A 1 8x16A 10mm2 1 x M40 (17-28 mmØ) 20kg EXKO 214 600 G 0000
8 x M25 (8-17 mmØ)
80A 2 12x16A 16mm2 1 x M40 (22-35 mmØ) 32kg EXKO 214 600 G 0001
12 x M25 (8-17 mmØ)
80A 3 24x16A 16mm2 1 x M40 (22-35 mmØ) 56kg EXKO 214 600 G 0002
24 x M25 (8-17 mmØ)
Version Type MCB with RCD 2-pole Terminal cross-section Cable gland Weight Order No.
40A 1 8x16A, 30mA 10mm2 1 x M40 (17-28 mmØ) 20kg EXKO 214 600 G 0003
8 x M25 (8-17 mmØ)
80A 2 12x16A, 30mA 16mm2 1 x M50 (22-35 mmØ) 32kg EXKO 214 600 G 0004
12 x M25 (8-17 mmØ)
80A 3 24x16A, 30mA 16mm2 1 x M50 (22-35 mmØ) 56kg EXKO 214 600 G 0005
24 x M25 (8-17 mmØ)
Version Type Socket outlets Cable gland Weight Order No.
2x16A 1 2x16A, 3-pole 1 x M40 (17-28 mmØ) 10kg EXKO 233 800 C 0001
2x16A 2 1x16A, 3-pole
1x32A1x16A, 5-pole
1x32A, 5-pole 1 x M40 20kg EXKO 233 800 C 0002
4x16A 3 2x16A, 3-pole
2x16A, 5-pole 1 x M40 25kg EXKO 233 800 C 0003
Ex de panel GHG619 is for lighting circuits, heating circuits, socket distributions.
Technical data
Ordering information mcb distribution for lighting circuits
Ordering information mcb distribution for heating circuits
Ordering information mcb distribution for sockets
Exde Panel - GHG619
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.16
Q1
L1L2L3 N PE
F1
16 A 16 A 16 A 16 A 16 A
1 N PE
F2
2 N PE
F3
3 N PE
F4
4 N PE
F5
5 N PE
L1
L2
L3
N
PE
to
F6
to
F…
Q1
L1L2L3 N PE
F1
16 A
30 mA
16 A 16 A 16 A 16 A
L1 N PE
30 mA
L 2 N PE
30 mA
L 3 N PE
30 mA
L 4 N PE
30 mA
L 5 N PE
F2 F3 F4 F5
L1
L2
L3
N
PE
to
F6
to
F…
X1 L1 L2 L3 N PE
F1
16 A 1 6 A
F2
L 1
L 2
L 3
N
P E
t o
F 5
to
F...
16 A 3 pol .
L N PE
X2
16 A 3 pol .
L N PE
16 A
F3
X3
16 A 5 pol .
L1 L2 L3 N PE
32 A
F4
X4
32 A 5 pol .
L1 L2 L3 N PE
Lighting distribution
Heating distribution
Socket distribution
Wiring diagram
Exde Panel - GHG619
3
2.3.17 EATON’S CROUSE-HINDS SERIES PORTFOLIO
271
817 817
544
544
817
817
544
271
Terminals
X 247
136
544 X 520
7
F...
F...
Terminals
136
270
X 247
7
817 X 793
F... F...
Terminals
271
X 247
271 210
X 247
7
544 X 520
Type 1 Type 2 Type 3
Lighting distribution/heating circuit distribution
Type 1 Type 2
Type 3
6ocNet distriEution ; fi[ing diPension
Dimension
Exde Panel - GHG619
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.18
Marking accd. to ATEX II 2 G Ex de ia/ib m [ia/ib] IIC T6/T5/T4
II 2 D Ex tD A21 IP66/IP65 T80 °C, T95 °C
EC-7ype Examination Certificate PTB 99 ATEX 1044 / BVS 22 ATEX E 006
Permissible ambient temperature ȁ20 rC up to +40 rC
ȁ55 rC up to +55 rC (option)
,ECEx Certificate of Conformity IECEx BKI 07.0023 / IECEx BVS 22.00087
Marking accd. to IECEx Ex de ia/ib m [ia/ib] T4 ... T6
Ex tD A21 IP66 T80 °C
GB-certification of conformity CCC
Rated voltage 690 V
Rated current 400 A
Protection class I
Terminal cross section up to 300 mm2
Degree of protection accd. to EN 60529 IP66
Enclosure material Stainless steel AISI 316 L
Enclosure colour Electro-polished
Content Type MCB 2-pole Connection terminals Cable glands Weight approx. Order No.
40 A 1 8 x 16 A 10 mm2 1 x M40 (17 - 28 mm Ø)
8 x M25 ( 8 - 17 mm Ø) 22 kg EXKO 223 100 Q 0000
80 A 2 12 x 16 A 16 mm2 1 x M50 (22 - 35 mm Ø)
12 x M25 ( 8 - 17 mm Ø) 34 kg EXKO 223 100 Q 0001
80 A 3 24 x 16 A 16 mm2 1 x M50 (22 - 35 mm Ø)
24 x M25 ( 8 - 17 mm Ø) 58 kg EXKO 223 100 Q 0002
Content Type RCBO 2-pole Connection terminals Cable glands Weight approx. Order No.
40 A 1 8 x 16 A, 30 mA 10 mm2 1 x M40 (17 - 28 mm Ø)
8 x M25 ( 8 - 17 mm Ø) 22 kg EXKO 223 100 Q 0003
80 A 2 12 x 16 A, 30 mA 16 mm2 1 x M50 (22 - 35 mm Ø)
12 x M25 ( 8 - 17 mm Ø) 34 kg EXKO 223 100 Q 0004
80 A 3 24 x 16 A, 30 mA 16 mm2 1 x M50 (22 - 35 mm Ø)
24 x M25 ( 8 - 17 mm Ø) 58 kg EXKO 223 100 Q 0005
MCB distribution for lighting circuits I heating circuits I socket distribution
Technical data
Ordering details distribution for lighting circuits
Ordering details distribution for heating circuits
Ordering details distribution for sockets
Exde Panel - GHG619
Content MCB Type Socket outlets Cable glands Weight approx. Order No.
2 x 16 A 1 2 x 16 A 3-pole 1 x M40 (17 - 28 mm Ø) 12 kg EXKO 223 800 C 0004
2 x 16 A 2 1 x 16 A 3-pole
1 x 32 A 1 x 16 A 5-pole
1 x 32 A 5-pole 1 x M40 22 kg EXKO 223 800 C 0005
4 x 16 A 3 2 x 16 A 3-pole
2 x 16 A 5-pole 1 x M40 27 kg EXKO 223 800 C 0006
3
2.3.19 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Wiring diagram lighting distribution I heating circuits I socket distribution
Exde Panel - GHG619
Q1
L1L2L3 N PE
F1
16 A 16 A 16 A 16 A 16 A
1 N PE
F2
2 N PE
F3
3 N PE
F4
4 N PE
F5
5 N PE
L1
L2
L3
N
PE
to
F6
to
F…
Q1
L1L2L3 N PE
F1
16 A
30 mA
16 A 16 A 16 A 16 A
L1 N PE
30 mA
L 2 N PE
30 mA
L 3 N PE
30 mA
L 4 N PE
30 mA
L 5 N PE
F2 F3 F4 F5
L1
L2
L3
N
PE
to
F6
to
F…
X1 L1L2 L3 NP E
F1
16 A1 6A
F2
L1
L2
L3
N
PE
to
F5
to
F...
16 A3 pol.
LN PE
X2
16 A3 pol.
LN PE
16 A
F3
X3
16 A5 pol.
L1 L2 L3N PE
32 A
F4
X4
32 A5 pol.
L1 L2 L3N PE
Lighting distribution
Heating circuits
Socket distribution
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.20
Dimension
Exde Panel - GHG619
Type 1
Lighting distribution/heating circuits X = fixing dimension
Type 3
1epyT 2epyT
noitubirtsidtekcoS noisnemidgnifix=X
2epyT 3epyT
312.5
941.5
X 362.5
392.5
X 876
O I
627
X 677
707
941.5X 561 X 315
8
941.5
X 991
1021
8
941.5X 561 X 315
X 362.5
151
135 312.5
X 561.5 627
X 362.5 151
135 312.5
941.5 X 876
X 677
627
151
135
X 561.5 627
3
2.3.21 EATON’S CROUSE-HINDS SERIES PORTFOLIO
SynergEX panelboards for hazardous rated areas
One of the biggest challenges with enclosures located in
hazardous areas is accessibility. To access internal
components for preventative maintenance or troubleshooting,
up to 70 bolts have to be loosened and then retightened,
leading to extended periods of downtime and safety risks due
to improperly torqued or missing bolts.
The SynergEX panelboard by Eaton’s Crouse-Hinds Division
utilizes individually encapsulated circuit breakers to reduce
downtime, increase safety and lower maintenance costs in
hazardous locations.
Application
Provide overcurrent and short circuit protection for low
voltage power, lighting and heat tracing applications in
hazardous locations, such as refineries, chemical and
petrochemical plants, mining, food processing, corrosive and
industrial processing facilities.
Certifications
• Class I, Division 2, Groups A, B, C, D
• Class II, Division 2, Groups F and G
• Zone 2 Ex ec IIC Gc T4
• Zone 22
• UL67
• CSA C22.2 No. 29
• UL60079-7
• CSA-C22.2 No.60079-15:2012
• IP66
Electrical ratings
SynergEX panelboard:
• Max. 225A/phase
(three phase max.)
• Max. 480/277 V
• Max. 225A main breaker
Encapsulated branch circuit breakers:*
• 120/240 VAC
– 1-pole and 2-pole
– 10, 15, 20, 25, 30, 35, 40 amps
– 1-pole GFI and EPD
– Auxiliary and trip indicator contact
• 208/120 VAC
– 1-pole, 2-pole and 3-pole
– 10, 15, 20, 25, 30, 35, 40 amps
– 1-pole GFI and EPD
– Auxiliary and trip indicator contact (On-chassis mains 10 - 40A)
• 480/277 VAC
– 1-pole, 2-pole and 3-pole
– 10, 15, 20, 25, 30, 35, 40 amps
Auxiliary and trip indicator contact
* 10A to 40A: 10 kA short circuit rating
Encapsulated main circuit breakers:*
• Up to 480/277 V
– 2- and 3-pole
– 10, 20, 30, and 40A amps back-fed on-chassis main
– 50, 60, 80, 100, 125, 150, 175, 200, and 225 amps off-chassis
main
– Auxiliary switch with trip indicator contact on circuit breaker,
1NO & 1NC Auxiliary; 1NO trip indicator contact (off-chassis
main 50A to 225A )
- Shunt trip (off-chassis main 50A to 225A)
* 10A to 40A: 10 kA short circuit rating
* 50A to 225A: 25 kA short circuit rating
Environmental ratings
• NEMA 3R, 4, 4X
• Temperature class: T4
• Ambient temperature: -20°C to +55°C (default)
-40°C to +55°C (with HT1 and HT2 suffix)
Field swappable breakers
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.22
50A-225A main breaker
Main breaker
• Lightweight and
compact main breaker is
encapsulated and internally
mounted
• Easy connection to the
busbar
• Push-to-trip mechanism for
manual trip and testing of
the breaker operation (offchassis main)
Unparalleled safety & flexibility in the field
• Proven reliability from Eaton's Crouse-Hinds tamper-proof
encapsulated breakers
• The new EZFlex™ bus bar's patented design allows for breaker
swap out in the field.
Save time and money
• Easy to open and access with only ¼ turn (versus up to 70+
bolts in a traditional enclosure)
• Lower maintenance costs
• Lightweight design and reduced footprint for easier installation
with reduced labor costs
Faster build-time and delivery
• Built in-house at Eaton's Crouse-Hinds Houston Texas location
• In-stock panels reduce lead-times and are available for ten day
quick ship program (refer to the SynergEX Quick Ship Program
flyer for more details) * For over 66 circuits, multiple enclosures are stacked and coupled. Coupling
kit provided and maintains NEMA ratings.
Multiple product designs and options
• 6 - 66 circuits with in one enclosure
• Removable gland plates for easy addition of entries standard
on all sizes
• Enclosure and door – 316L stainless steel
• Observation window – polycarbonate
• Hinges – 304 stainless steel
• Enclosure hardware – 8-18 stainless steel
• 1/4 turn handle – plastic
• Backpan – 5052 H32 aluminum
• Deadfront – 304 stainless steel
• Internal parts (screws, nuts washers) – zinc plated steel
• Door gasket – polyurethane foam
• Window and gland plate gasket – Poron M19
• Power distribution block lugs – tin plated copper
• Bonding/grounding assembly – aluminum
• Circuit breakers – flame rated nylon
• Breaker handles – Type 6/6 nylon
Materials
SynergEX panelboards for hazardous rated areas
A 3-Pole breaker can be replaced with three
single pole breakers without making any
modification to the bus bar.
3
2.3.23 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Finish: Tinned
Material: Copper;
Thermoplastic Elastomer
Dielectric Strength: 20 kV/mm
Flammability Rating: UL 94V-0
Halogen Free Rating: UL 2885;
IEC 60754-1; IEC 62821-1
Low Smoke Rating: IEC 61034-
2; ISO 5659-2; UL 2885
Smoke, Toxicity and Acidity
Rating: IEC 60754-2
UV Resistance Rating: UL 854;
UL 2556
Insulation Elongation: 500%
Insulation Thickness: 0.07\"
Nominal Voltage, UL/CSA/IEC:
1,000 VAC; 1,500 VDC
Working Temperature:
-58° to 239° F
Complies With: IEC 60695-2-
11 (Glow Wire Test 960°C);
IEC 61439.1; IEC 61439.1 Class
II
The EZFlex™ bus bar provides maintenance-free design and
allows breaker interchangeability. The bus does not have any
threaded fasteners that would require any periodic
maintenance. The branch breaker conductors are
exothermically welded to provide a permanent molecular
bond that will not loosen or corrode and have a currentcarrying capacity equal to or higher than that of the
conductor. These connections can withstand repeated fault
currents and are designed to maintain integrity for the life of
the installation.
Features
• Compact power block with high short circuit current rating
• Tinned copper or aluminum block allows for copper or
aluminum conductor direct connections, or using ferrule
• Screw retaining cover is hinged and removable
• Design allows for visual inspection of conductor and
confirmation of connection
• Voltage detection and measurement connection
• 95% fill ratio
Certification Details: UL 1059
Complies With: IEC 60947-7-1
Enclosure Rating: IP 20
Flammability Rating: UL 94V-0
Certifications: RoHS, UL, UR
• Thin layers of tinned electrolytic copper formed into a stack
• Insulated by high-resistance, halogen free, flame retardant and
low smoke material with less than 20% contact with conductor
for high flexibility
• Dramatically smaller and more flexible than comparable cable
based on ampacity
• Better power density than cable with lower skin effect ratio
• Weight savings and material savings compared to wire
alternatives
• 100% production dielectric tested
• RoHS compliant
Features Specifications
Power block
The Power block provides the customer connection for the
incoming cables of the main lug only panels. The high short
circuit rated large cross-section blocks offer time savings and
reliability in every MLO panel configuration
EZFlex™ bus bar
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.24
Max breaker spaces
Enclosure size
Dimensions
HxWxD
With MLO or <50A
MCB*
With
>50A MCB*
A нк x мо x лк\" лм р
B но x мо x лк\" лт лм
C ну x мо x лк\" мо лт
D он x мо x лк\" нк мо
E ос x мо x лк\" нр нк
F пм x мо x лк\" ом нр
G пр x мо x лк\" от ом
H ру x мо x лк рр рк
L** Coupled enclosure, vertical
M** Coupled enclosure, horizontal
* Total number of breakers selected must not exceed max breaker
spaces referenced above. 2-pole on chassis main breaker (<50A
MCB) takes 2 breaker spaces and 3- Pole on-chassis main takes three
breaker spaces
&ontact Podified products
Model
SSP Class I,
Division м
Consult factory for custom
options and materials.
Enclosure material/finish
S нлрL stainless steel,
natural finish
* GFI/EPD only available for 120V
applications.
Panel voltage rating
1 лмкȖШЪЦV
(single phase, н-wire)
2 лмкȖШЦЮV
(three phase, о-wire)
4* откȖШЭЭV
(three phase, о-wire)
*Total number of breaker spaces
utilized shall be rounded up to
an even number. Should be
represented as a 2 character
number for enclosure sizes A-H and
3 characters for sizes L & M.
Breaker spaces occupied
1 л-pole breaker л space
2 м-pole breaker; л-pole EPDȖ
G)I; л-pole AXȖSC м spaces
3 н-pole breaker; м-pole AXȖSC
н spaces
*Add up total breaker spaces used
SSP 36 –
SSPFS236-02310-03220-12140-01120E-01120G-03110-01110E-01110G-3M225-BD-GPA-HT1-I-LID
F S 2
Ordering information
Part number example
SynergEX panelboard, size F enclosure, 316L stainless steel, 120/208V (3 phase, 4-wire), (36) breaker spaces, (2) 3-pole 10A breakers, (3) 2-pole 20A breakers, (12) 1-pole 40A breaker, (1) 1-pole 20A EPD breaker, (1) 1-pole 20A
GFI breaker, (3) 1-pole 10A breakers, (1) 1-pole 10A EPD breaker, (1) 1-pole 10A GFI breaker, 3-pole 225A main breaker, Breather Drain, (8) gland plates, 120V heaters for -40°C temperature rating, inverted panelboard
(main connection at bottom), lamacoid ID
Enclosure size A B C D E F G H I Weight
A нк.кк
(срм)
мо.кк
(рлк)
лк.кк
(мпо)
нл.пр
(ткл)
мм.нт
(прт)
мт.пк
(смн)
мо.он
(рор)
мн.кк
(пто)
лс.рн
(оот)
лок lbs.
ро kg.
B но.кк
(трн)
мо.кк
(рлк)
лк.кк
(мпо)
нп.пр
(укн)
мм.нт
(прт)
нм.пк
(тмп)
мо.он
(рор)
мс.кк
(ртп)
лс.рн
(оот)
лпт lbs.
см kg.
C ну.кк
(уук)
мо.кк
(рлк)
лк.кк
(мпо)
ок.пр
(лкнк)
мм.нт
(прт)
нс.пк
(упм)
мо.он
(рор)
нм.кк
(тлм)
лс.рн
(оот)
лтм lbs.
тн kg.
D он.кк
(лкум)
мо.кк
(рлк)
лк.кк
(мпо)
оо.пр
(ллнл)
мм.нт
(прт)
ол.пк
(лкпо)
мо.он
(рор)
нр.кк
(уло)
лс.рн
(оот)
мкк lbs.
ул kg.
E ос.кк
(ллун)
мо.кк
(рлк)
лк.кк
(мпо)
от.пр
(лмнн)
мм.нт
(прт)
оп.пк
(ллпп)
мо.он
(рор)
ок.кк
(лклр)
лс.рн
(оот)
млу lbs.
уу kg.
F пм.кк
(лнмк)
мо.кк
(рлк)
лк.кк
(мпо)
пн.пр
(лнрк)
мм.нт
(прт)
пк.пк
(лмтм)
мо.он
(рор)
оп.кк
(ллон)
лс.рн
(оот)
мом lbs.
ллк kg.
G пр.кк
(ломм)
мо.кк
(рлк)
лк.кк
(мпо)
пс.пр
(лорм)
мм.нт
(прт)
по.пк
(лнто)
мо.он
(рор)
оу.кк
(лмоо)
лс.рн
(оот)
мрл lbs.
ллт kg.
H ру.кк
(лспм)
мо.кк
(рлк)
лк.кк
(мпо)
ск.пр
(лсум)
мм.нт
(прт)
рс.пк
(лсло)
мо.он
(рор)
рм.кк
(лпсо)
лс.пу
(оос)
нмл lbs.
лор kg.
Dimensions and weight
SynergEX panelboards for hazardous rated areas
3
2.3.25 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Note: No spaces in part number configuration To add the following options to the
panelboard, add a dash and then the
suffix to the end of the catalog number –
suffixes are added alphanumerically.
Branch breaker order to be
deterPined first E\\ pole count
high to low. Then, within common
pole count breakers, order to be
determined by amperage, high
to low. Then, within common
amperage, order to be determined
by style in the following oder:
standard, E, G, AX, SC.
* For over 66 circuits,
multiple enclosures are
stacked and coupled.
,I %L6 su[ is used the EreaNer location specification
chart needs to Ee filled out and suEPitted Zith the
order entry.
&ontact Podified products
*EPD and GFI breakers are rated for for 120/240V applications
(can not be used for 480/277V panels)
Branch breaker poles
1 л-pole breaker
2 м-pole breaker
3 н-pole breaker
3-pole 2-pole 1-pole EPD/GFI*
лк лк (AX,SC) лк (AX,SC) ȁ
лп лп (AX,SC) лп (AX,SC) лпEȖЧЫG
мк мк (AX,SC) мк (AX,SC) мкEȖШЦG
мп мп (AX,SC) мп (AX,SC) ȁ
нк нк нк нкEȖЩЦG
нп нп нп ȁ
ок ок ок окEȖЪЦG
See breaker spaces occupied section
AX = Breaker + (1) Form C Aux Contact
SC = Breaker + (1) Form C Trip Indicator Contact
E = 1P EPD (Ground Fault Equipment Protectors - 30 mA Sensitivity)
G = 1P GFI (Ground Fault Circuit Breakers - 5 mA Sensitivity)
QTY of alike breakers
01-132 л minimum,
лнм maximum
Add up # of alike breakers
Main circuit breaker
BLANK Main lug only (ммпA)
2M м-pole main circuit breaker (for
single phase systems)
3M н-pole main circuit breaker (for
three phase systems)
Main breaker amperage
10A - 225A
10 лк amps, м- or н-pole
20 мк amps, м- or н-pole
30 нк amps, м- or н-pole
40 ок amps, м- or н-pole
50 пк amps, м- or н-pole
60 рк amps, м- or н-pole
80 тк amps, м- or н-pole
100 лкк amps, м- or н-pole
125 лмп amps, м- or н-pole
150 лпк amps, м- or н-pole
175 лсп amps, м- or н-pole
200 мкк amps, м- or н-pole
225 ммп amps, м- or н-pole
Options
BLS* Breaker location specification (Customer specified
branch breaker location)
BST Shunt Trip, 120V (for main breakers over 50A)
DR###### \"DR\" followed by numerical drawing number
indicates Modified Products
GPA All gland plates included
GPN No gland plates included
HC1 +eater system for internal condensation, лмкV
HC2 Heater system for internal condensation, 277V
HT1 Heater system for -40°C temperature, 120V
HT2 Heater system for -40°C temperature, 277V
I Inverted Panelboard
(main connection at bottom)
LID Lamacoid tag for customer specified identification
LIT** Branch circuit indication lights
LLD** Load side of MCB voltage indication
LLN** Incoming power voltage indication
S784
Auxiliary switch with trip indicator contact on
circuit breaker, 1NO & 1NC Auxiliary; 1NO trip
indicator contact
SID Stainless steel tag for customer specified
identification
02310-03220-12140-01120E-01120G-03110-01110E-01110G – 3M BD-GPA-HT1-I-LID
#1. Pick
quantity
#3. Pick
type
#2. Breaker
style
02310-03220
Each new series
followed by dash
Default configuration
Gland plate dimensions = 10\" x 6\"
Enclosure sizes A–H
GP7 GP4
GP6 GP5
225
GPA option
GP1 GP2
GP4 GP3
GP7
GP5
GP8
GP6
Gland plate locations
GPN option
–
SynergEX panelboards for hazardous rated areas
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.26
EC-type examination certificate PTB 08 ATEX 1043 X
,ECEx-certification of conformity IECEx PTB 11.0077X
Marking to 94/9/EC II 2 G Ex de IIB / IIB + +2, T5, T6 / II 2 D tD A21 IP66
EC-7ype examination certificate PTB 08 ATEX 1042U
Permissible ambient temperature -20 rC to +40 rC
-55 rC to +55 rC (option)
Rated voltage 690 V
Rated current 1150 A
Terminal cross-section Up to 240 mm2
Degree of protection acc. to EN 60529 IP65 (IP66 as option)
Weight See ordering details
Enclousre material Aluminium die-cast housing, powder coated
Enclosure colour RAL 7032/7022
Version Power dissipation (Tamb. = 40 °C) Weight Dimenensions Order No.
T6 T5 L x W x D
Ex d light alloy empty enclosures
Size 1 94 W 134 W 10.5 kg 210 x 210 x 191 mm GHG 640 1901 R0001
Size 2 112 W 158 W 14 kg 320 x 210 x 191 mm GHG 640 1902 R0001
Size 4 152 W 214 W 18 kg 320 x 320 x 191 mm GHG 640 1904 R0001
Size 5 197 W 280 W 21 kg 320 x 320 x 284 mm GHG 640 1905 R0001
Size 8 270 W 390 W 35 kg 430 x 430 x 284 mm GHG 640 1908 R0001
Size 9 390 W 430 W 53 kg 650 x 430 x 284 mm GHG 640 1909 R0001
Size 10 470 W 640 W 73 kg 650 x 430 x 439 mm GHG 640 1910 R0001
Size 11 470 W 640 W 105 kg 650 x 650 x 442 mm GHG 640 1911 R0001
Technical data
Ordering details empty enclosures (II B)
Ex d light alloy empty enclosure GHG 64
Product features
• Temperautre range from -55 °C to +55 °C
• Ex d II B + H2
• Rated voltage up to 690 V rated current up to 1150 A
• Hinged cover with 110° openening angle
• Designed for easy maintenance
• Degree of protection IP65 (IP66 optional)
• Broad range of new Ex-d actuators and built-in components
Product introduction
Whether offshore applications, the usage in harsh
environPents oI chePical plants or refineriesffl The neZ poZder
coated light metal enclosures of the GHG 64 series provide
the highest standard of explosion protection. The flat flame
path, the modular design as well as the extended temperature
range (from- 55 °C up to +55 °C) are highlights of the GHG 64
series. In addition, the enclosure can be equipped with an high
amount of the new Ex-d actuators, due to the compact design
of the enclosures. The enclosures design is optimised to merge
the contrasts of weight reduction and strength increase. The
extra - ordinary rugged hinges are particularly designed to
open the cover even if the GHG 64 is mounted directly side
by side. Therefore, just unfasten the captive screws and by
means of the innovative pull and swing hinges the cover can
easil\\ Ee opened This siPplifies Paintenance and speeds up
both repair work and there placement of built-in components.
Furthermore, the indi - vidual enclosures can be coupled
together using flameproof bushings. With eleven enclosure
sizes to choose from, customised solutions for any specific
application can be provided.
Size 11 Size 9 Size 4 Size 1
3
2.3.27 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Marking to 94/9/EC II 2 G Ex d II
EC-7ype Examination Certificate PTB 06 ATEX 1009U
Permissible ambient temperature -20 rC to +40 rC
-55 rC to +55 rC (option)
Rated voltage switch 690 V
Rated voltage indication lamp 230 V
Rated current (switch) 63 A
Degree of protection acc. to EN 60529 IP65 (IP66 as option)
Ex-d fixing thread M22 x 1.5
Technical data
Ex-d built-in control units / signal units / actuators for GHG 64
Product features
• Pushbuttons (up to 4 poles with any
combination of N/O and N/C)
• Pushbuttons with emergency stop function
• Key-operated switches / pushbuttons
• Indicating lamp in various colours
• Padlocking facilities
• Type labels
• Actuators for circuit breakers
Product introduction
In addition to the known bus bar and connection boxes, a wide
variety of new built-in components, such as switches, indicating
devices, actuators and contact blocks, allow a multitude of
combinations for customised complex controls. Threaded Ex-d
holes in accordance Zith \\our specifications are drilled into the
enclosure covers in our works.
The desired components are simply crewed into those drillings.
Each part can be easily exchanged due to the modular layout
of the actuators and contact blocks: Simply by opening the
bayonet coupling between the actuator and the contact block.
The contact blocks provide all combinations of N/O and N/C
from 1 pole up to 4 poles.
Durable LED indicator lamps ensure safe operation on a lasting
basis. Actuating elements for various MCBs resp. RCDs and
mushroomhead pushbuttons, key-operated switches or photocell inserts complete the product range.
Signal lamp Key operated pushbutton Pushbutton Mushroom head w. look Mushroom head pushbutton
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.28
Version Order No.
Contact block
1 NO GHG 640 9617 P0001
1 NC GHG 640 9617 P0002
1 NO + 1 NC G+G 640 9617 P0003
2 NO GHG 640 9617 P0004
2 NC GHG 640 9617 P0005
2 NO + 1 NC G+G 640 9617 P0006
1 NO + 2 NC G+G 640 9617 P0007
2 NO + 2 NC G+G 640 9617 P0008
3 NO + 1 NC G+G 640 9617 P0009
1 NO + 3 NC G+G 640 9617 P0010
4 NO GHG 640 9617 P0011
4 NC GHG 640 9617 P0012
Signal lamp unit
Green GHG 640 9614 P0001
Red GHG 640 9614 P0002
Yellow GHG 640 9614 P0003
Blue GHG 640 9614 P0004
Clear GHG 640 9614 P0005
Mushroom head pushbutton / emergency stop pushbutton
D 36 mm with lock GHG 640 9603 P0001
D 50 mm with lock GHG 640 9603 P0002
with rotary latch GHG 640 9604 P0001
Emergency stop pushbutton GHG 640 9606 P0001
Pushbutton
Yellow GHG 640 9607 P0001
Blue GHG 640 9607 P0002
Red GHG 640 9607 P0003
Green GHG 640 9607 P0004
White GHG 640 9607 P0005
Black GHG 640 9607 P0006
Key-operated pushbutton
with 2 keys GHG 640 9608 P0001
Actuator
Rotary actuator for MCBs GHG 640 9602 P0001
Rotary actuator for 20 A / 32 - 63 A GHG 640 9612 P0001
Locking device
Pushbutton pressed GHG 640 9614 P0001
Pushbutton unpressed GHG 640 9614 P0001
MCB actuator GHG 640 9614 P0003
Ordering details empty enclosures (II B)
Signal lamp Key operated pushbutton Pushbutton Mushroom head w. look Mushroom head pushbutton
Ex-d built-in control units / signal units / actuators for GHG 64
3
2.3.29 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Free standing
motor control
panel
Mounting configurations
Wall mounted circuit breaker distribution panel
EPBA control panel
Product introduction
EPBA control panel is designed for group IIB for the hazardous areas of Zone
1 and Zone 2. The custom built panels are used as distribution panels for
motor control and indications.
Technical data
Certificate of conformity ANZEx 06.3018X
ANZEx 06.3049X
Type of protection Exd
Degree of protection IP66
Gas group IIB or IIB (H2)
Standard materials Body & cover - copper free aluminum
Cover screws - stainless steel
Hinges (to size 1616) stainless steel
Hinges (size 2418 & above) copper free
aluminum
Gasket - neoprene
Branch circuit breakers - investment cast
stainless steel
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.30
Earth bar mounted in base for connection
of earth wiring on outgoing circuits
Screw fastened blank traffolyte
label provided for each branch circuit breaker
Lock out facility provided on all circuit breaker operator handles Supplied with circuit
breakers factory
wired to terminals
mounted in the base Supply wiring connected direct to main circuit breaker
Ordering information
Dimension
Cat.No. A B C D E F
EPBA1212 415 415 230 285 143 405
EPBA1616 516 516 230 285 242 505
EPBA2418 750 595 295 350 413 556
EPBA2424 750 750 295 350 413 708
EPBA control panel
EPBA 2424A - 4 2P 20 - 22P16 - 42P10 - 4M125 - C
EPBA
Panel board
prefix
Panel board size
2424
No. of branch
circuit breakers
4
No. of poles
circuit breakers
2P
Circuit breaker
trip rating (A)
20
Additional breakers
2 pole 16A 22P16
2 pole 10A 22P10 Main
circuit breaker
4M125
Option
IIC
Please consult factory for availability Note: Main circuit breaker is provided only when specified in catalogue number
Pre-drilled &
tapped
entries
3
2.3.31 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Dimension
Cat.No. A B C D E F Mtg Screws
EJBA464 215 165 122 135 145 150 M6
EJBA783 280 240 87 115 230 192 M8
EJBA786 280 240 87 170 230 192 M8
EJBA886 280 280 180 230 140 280 M8
EJBA1286 280 380 175 225 168 305 M12
EJBA9166 305 485 175 225 242 325 M12
EJBA121208 415 415 230 285 143 395 M6
EJBA161608 516 516 230 285 242 505 M8
EJBA211710 654 545 323 355 300 610 M8
EJBA241810 595 750 295 350 413 556 M8
EJBA242410 750 750 295 350 413 708 M12
Note: All drilling and tapping of entries must be carried out by the manufacturer to ensure that certification requirements are not breached. Whilst mounting of
devices such as relays etc. can be carried out in the future if the enclosure is provided with a mounting plate, care should be taken with devices which are likely to
raise the surface temperature of the enclosure.
EJBA junction boxes
Product introduction
EJBA made of cast copper free aluminium is designed for the hazardous
areas of Zone 1 and Zone 2. It can be used as terminal box or bus bar system
junction box with terminals:
- To enclose equipment and control devices, relays, contactors and/or
instruments;
- To house custom built panels (refer to H14 custom built panels).
Technical data
Certificate of conformity ANZEx 06.3018X
Type of protection Exd
Degree of protection IP66
Gas group IIB or IIB ++2
Standard materials Body & cover - cast copper free aluminium
Options Grey polyurethane finish
Captive cover screws
Marine grade paint
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.32
Product introduction
Technical data
,ECEx-certification of conformity IECEx NEP 21.0012X
GB-certification of conformity CCC
Marking acc. to IECEx Ex db >ia IIC Ga / ib IIC Gb@ IIB++2 T4, T5, T6 Gb
Ex tb >ia IIIC Da / ib IIIC Db@ IIIC T130˚C, T95˚C, T80˚C Db IP66/65
Standard material body and cover - copper-free aluminum, ZL104 (<0.1%) gasket - silicone
cover bolts and hinges - steel
coating - RAL7016 for cover, RAL7032 for body
Cover devices signal lamps
pushbuttons rotary switches
circuit breaker handles
round window, Ø 80 mm
Permissible ambient temp. - 40˚C to +55˚C
CPD15 series enclosure is made of Copper-free Aluminum
body and cover with corrosive resistant coating, which is
optiPi]ed range oI application Ior ,,% +2 The series Iulfills
IP66 according to IEC60079-0, IEC60079-1, IEC60079-31.
CPD15 series enclosure has large entry area for individual
solutions.
CPD15 series flameproof enclosures
• Earthing continuity
Standard steel hinges are designed to link cover and body
and ensureearth continuity between them
External earth stud can be added as an option
• Coating
Thermoset polyester coating can endure 200hrs saline mist
• Standard internal mounting plate
Product features
Ordering information
• Removable mounting tags
$lloZ eas\\ fieldreplacePent in case Pounting Ieet are
damaged or broken
• Standard silicone gasket
Comes standard in all sizes
Provide IP66 protection for enclosure
CPD15 100 XX YY
Product series Size Configuration
02 - 474 x 426 x 291 03 = IIB + +2, IP65 (with window)
03 - 577 x 426 x 291 07 = IIB + +2, IP66
04 - 680 x 529 x 291
3
2.3.33 EATON’S CROUSE-HINDS SERIES PORTFOLIO
CPD15 series flameproof enclosures
Material number External dimensions Inside dimensions Mounting
A B B’ C A' B' C' D E
CPD 15 10002 YY 474 426 371 301 414 311 249 430 327
CPD 15 10003 YY 577 426 371 301 517 311 249 533 327
CPD 15 10004 YY 680 529 474 301 619 414 247 636 430
Dimension
Ordering details complete motor starter distribution
Ordering details complete isolation switch
Motor capacity
to AC 3 Enclosure size Connection terminals Cable entries Order No. with
signal lamp
Order No. without
signal lamp
1.1kW CPD15 size 2 6mm2 2xM25 CPD1510002MD011S CPD1510002MD011
1.5kW CPD15 size 2 6mm2 2xM25 CPD1510002MD015S CPD1510002MD015
2.2kW CPD15 size 2 6mm2 2xM25 CPD1510002MD022S CPD1510002MD022
3kW CPD15 size 2 10mm2 2xM25 CPD1510002MD030S CPD1510002MD030
4kW CPD15 size 2 10mm2 2xM25 CPD1510002MD040S CPD1510002MD040
5.5kW CPD15 size 2 16mm2 2xM25 CPD1510002MD055S CPD1510002MD055
7.5kW CPD15 size 2 16mm2 2xM25 CPD1510002MD075S CPD1510002MD075
11kW CPD15 size 2 16mm2 2xM25 CPD1510002MD110S CPD1510002MD110
15kW CPD15 size 2 16mm2 2xM25 CPD1510002MD150S CPD1510002MD150
Motor capacity to AC 3 Enclosure size Connection terminals Cable entries Order No. with
signal lamp
Order No. without
signal lamp
22kW CPD15 size 4 35mm2 2xM32 CPD1510004MS022S CPD1510004MS022
30kW CPD15 size 4 35mm2 2xM32 CPD1510004MS030S CPD1510004MS030
37kW CPD15 size 4 35mm2 2xM32 CPD1510004MS037S CPD1510004MS037
45kW CPD15 size 4 50mm2 2xM40 CPD1510004MS045S CPD1510004MS045
55kW CPD15 size 4 50mm2 2xM40 CPD1510004MS055S CPD1510004MS055
Current Enclosure size Cable entries Order No. (3 poles) Order No. (4 poles)
10A CPD15 size 2 2xM25 CPD1510002IS3010 CPD1510002IS4010
20A CPD15 size 2 2xM25 CPD1510002IS3020 CPD1510002IS4020
40A CPD15 size 3 2xM32 CPD1510003IS3040 CPD1510003IS4040
80A CPD15 size 3 2xM32 CPD1510003IS3080 CPD1510003IS4080
Direct circuit
Star-delta circuit
Drawing details
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.34
EC-type examination certificate LOM 08 ATEX 2071X
,ECEx-certification of conformity IECEx BKI 07.0018
GB certificate of conformity CCC
Marking acc. to ATEX II 2 G Ex d IIB T4ȏT6
II 2 G Ex d [ia/ib] IIB T6
Marking accd. to IECEx Ex d IIB T4ȏT6
Ex d [ia/ib] IIB T6
Material/Finish Light alloy, RAL7016/RAL7032
Rated voltage 690V
Max. rated current 1200A
Terminal Up to 240 mm2
Temperature range -20 ˚Ca+55 ˚C
Application Zone 1 and Zone 2
Technical data
EJB 12A
EJB 110 EJB 120 EJB 130 EJB 241 M1
EJB 14R EJB 23R
Product introduction
The (-% range is an $T(; ,(&([ and *%&&& certified ΌaPeprooI
enclosure for category 2, Zone 1, Zone 2 application and fully
complaint with the impact, thermal and ingress requirements
of EN60079 and GB3836. EJB is available in comprehensive
range of different sizes, each with the facility for various
configuration possiEilities Ior a Pultitude oI applications
EJB series had become the first choice for customers
because of its classic design, high quality and brilliant overall
performance.
EJB flameproof enclosures
3
2.3.35 EATON’S CROUSE-HINDS SERIES PORTFOLIO
External dimension (mm) Type A B C Windows A' B' C' D
EJB 12R 216 130 106 178 86 59 220 144
EJB 12A 216 130 162 178 86 115 220 144
EJB 14R 420 150 143 367 104 95 424 159
EJB 23R 337 217 211 274 164 166 333 219
EJB 110 371 371 233 311 311 179 327 327
EJB 120 474 371 233 414 311 177 430 327
EJB 121 474 371 305 414 311 249 430 327
EJB 130 577 371 233 517 311 177 533 327
EJB 131 577 371 305 517 311 249 533 327
EJB 240 680 474 233 619 414 175 636 430
EJB 241 680 474 305 619 414 247 636 430
EJB 241 M1 680 474 305 230 x 255 619 414 247 636 430
A
B
E C
B' C'
DA'
8,5
B
D
A C
Max. dissipation powerMax. rated Explosive dust Type T6 T5 T4 current Gas group IP rating application Weight(kg)
EJB 12R 30 60 100W 40A IIB IP65 3.00
EJB 12A 30 60 100W 40A IIB IP65 3.60
EJB 14R 80 140 240W 65A IIB IP65 8.30
EJB 23R 60 140 240W 100A IIB IP65 11.00
EJB 110 125 170 295W IIB IP65 22.00
EJB 120 150 270 480W 300A IIB IP65 28.50
EJB 121 150 280 500W 350A IIB+H IP66* Yes 32.00
EJB 130 200 340 590W 450A IIB IP65 35.30
EJB 131 200 350 610W 500A IIB+H2 IP66* Yes 39.00
EJB 240 250 400 700W 800A IIB IP65 52.30
EJB 241 250 400 700W 850A IIB+H2 IP66* Yes 56.80
EJB 241 M1 250 400 700W
Enclosure details
Dimension
EJB flameproof enclosures
Type
7aȰŏC 7aȰŏC Gas
group Dust group IP Weight 77ŏC 77ffiŏC 77flŏC 77ŏC 77ffiŏC 77flŏC
EJB 12R 100 60 30 83 43 18 IIB No IP65 3.22
EJB 12A 100 60 30 83 43 18 IIB No IP65 3.68
EJB 14R 240 140 80 200 100 50 IIB No IP65 8.30
EJB 23R... 240 140 60 200 100 35 IIB No IP65 11.21
EJB 110 295 170 125 245 120 75 IIB No IP65 22.50
EJB 120 480 270 150 400 195 90 IIB No IP65 27.00
EJB 121 500 280 150 415 200 90 IIB No IP65 31.00
EJB 130 590 340 200 490 245 125 IIB No IP65 37.00
EJB 131... 610 350 200 505 250 125 IIB No IP65 39.50
EJB 240 700 400 250 580 290 155 IIB No IP65 49.5
EJB 241 700 400 250 580 290 155 IIB No IP65 56.80
EJB 241M1 700 400 250 580 290 155 IIB No IP65 90.9
(1)Changed to IP65 when a ø80 window applied
Type External dimension Internal dimension Windows Mounting
A B C A' B' C' D E
EJB 12R 216 130 106 178 86 59 220 144
EJB 12A 216 130 162 178 86 115 220 144
EJB 14R 420 150 143 367 104 95 424 159
EJB 23R 337 217 212 274 164 166 333 219
EJB 110 371 371 233 311 311 179 327 327
EJB 120 474 370 233 414 311 177 430 327
EJB 120M3 474 371 233 414 311 177 110x75 430 327
EJB 120M4 474 371 233 414 311 177 180x140 430 327
EJB 121... 474 371 305 414 311 249 430 327
EJB 130 577 371 233 517 311 177 533 327
EJB 131... 577 371 305 517 311 249 533 327
EJB 240 680 474 233 619 414 175 636 430
EJB 241... 680 474 305 619 414 247 636 430
EJB 241M1 680 474 305 619 414 247 255x230 636 430
3
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.3.36
Degree of protection IP65 acc, EN60529
Ex. Certification ATEX EEx d IIB, GB Ex d IIB
Description Code Qty.
Push-button with 1NO + 1NC contacts block:
Sensitive push-button + Labels《White》,《I》,《0》,《STOP》,《START》 NOR 000 001 170 004 1
Sensitive push-button locked by padlock in pressed position + Labels
《White》,《I》,《0》,《STOP》,《START》 NOR 000 001 170 005 1
Sensitive push-button locked by padlock in depressed position + Labels
《White》,《I》,《0》,《STOP》,《START》 NOR 000 001 170 006 1
Mushroom sensitive push-botton + Labels《0》,《STOP》,《O))》,《Red》,and《Yellow》 NOR 000 001 170 007 1
Mushroom retained push-button + Lables
《0》,《STOP》,《O))》,《Red》, and《Yellow》 NOR 000 001 170 008 1
Mushroom retained push-button and locked by padlock + Labels
《0》,《STOP》,《O))》,《Red》, and《Yellow》 NOR 000 001 170 009 1
Key push-button NOR 000 001 170 010 1
Mushroom key push-button NOR 000 001 170 011 1
Sensitive push-button bottom box + Label《RESET》 NOR 000 001 170 012 1
Contact bocks
1NO NOR 000 001 170 013 1
1NC NOR 000 001 170 014 1
Pack Labels
1 Label of each inscription《II》,《Arrow》,《ON》,《RESET》,《TEST》,《Green》,
《Red》,《Yellow》and《Black》 NOR 000 001 170 015 1
Signal lamps
Direct lamp 240V + Lens《White》,《Amber》,《Red》,《Yellow》and《Green》
+ Lampholder + 3W lamp NOR 000 001 170 016 1
Direct lamp 130V + Lens《White》,《Amber》,《Red》,《Yellow》and《Green》
+ Lampholder + 2.6W lamp NOR 000 001 170 017 1
Direct lamp 24V + Lens《White》,《Amber》,《Red》,《Yellow》and《Green》
+ Lampholder + 1.2W lamp NOR 000 001 170 018 1
Indirect lamp by trafo 380-400/6V + Lens《White》,《Amber》,《Red》,《Yellow》and《Green》
+ Lampholder + 1.2W lamp NOR 000 001 170 019 1
Direct LED 230V + Lens《White》,《Amber》,《Red》,《Yellow》and 《Green》+ Lampholder NOR 000 001 170 116 1
Direct LED 130V + Lens《White》,《Amber》,《Red》,《Yellow》and《Green》+ Lampholder NOR 000 001 170 117 1
Direct LED 24V + Lens《White》,《Amber》,《Red》,《Yellow》
and《Green》 + Lampholder NOR 000 001 170 118 1
Control switches, locked by padlock + Label
Reversed《0-1》, 2P, 12A + Rotary handle NOR 000 001 170 020 1
Reversed《0-1》, 2P, 25A + Rotary handle NOR 000 001 170 021 1
Reversed《0-1》, 3P, 25A + Rotary handle NOR 000 001 170 022 1
Reversed《1-2》, 1P, 12A + Rotary handle NOR 000 001 170 023 1
Reversed《1-2》, 2P, 12A + Rotary handle NOR 000 001 170 024 1
Reversed《1-0-2》, 1P, 12A + Rotary handle NOR 000 001 170 025 1
Reversed《1-0-2》, 2P, 12A + Rotary handle NOR 000 001 170 026 1
Reversed《0-1》, 2P, 12A + Rotary handle NOR 000 001 170 027 1
Reversed《0-1-M》, 2P, 12A + Rotary handle NOR 000 001 170 028 1
Rotatory handly bottom enclosure locked by padlock
Actuator for 25A <63A switch NOR 000 001 170 029 1
Actuator for 63A <100A switch NOR 000 001 170 030 1
Actuator for 100A <250A switch NOR 000 001 170 031 1
Actuator for 250A 1000A switch NOR 000 001 170 032 1
Neutral label for switches
Label 60 x 60 NOR 000 001 170 033 1
Label 70 x 70 NOR 000 001 170 034 1
Label 85 x 85 NOR 000 001 170 035 1
Special actuators
Acutuator for MCB of 1P-ABB + Label NOR 000 001 170 933 1
Acutuator for MCB Multipole-ABB + Label NOR 000 001 170 925 1
Acutuator for MCB of 1P-M&G + Label NOR 000 001 170 600 1
Acutuator for MCB Multipole-M&G + Label NOR 000 001 170 569 1
Acutuator for MCB POWER + Label NOR 000 001 170 565 1
Bushings1)
3/4\" NPT 3P + N + PE 4x10mm2
+ 1x6mm2
50A NOR 000 001 170 892 1
1\" NPT 3P + N + PE 4x16mm2
+ 1x10mm2
75A NOR 000 001 170 909 1
1 1/2\" NPT 3P + N+PE 4x50mm2
+ 1x10mm2
150A NOR 000 001 170 917 1
Bus-bars
>350A, 3P + N + T+control 19x1.5mm2
application in size 1 NOR 000 001 170 036 1
>350A <500A, 3P + N + T + control 19x1.5mm2
application in size 1 NOR 000 001 170 037 1
>500A <630A, 3P (2 bars per phase) + N + T + control 19x1.5mm2
application size 2 NOR 000 001 170 038 1
>630A <800A, 3P (2 bars per phase) + N + T + control 19x1.5mm2
application size 2 NOR 000 001 170 039 1
Windows
60 x 60mm type:M 6060 NOR 000 001 170 000 1
75 x 75mm type:M 7575 NOR 000 001 170 001 1
110 x 50mm type:M 11050 NOR 000 001 170 002 1
110 x 75mm type:M 11075 NOR 000 001 170 003 1
End bars cover NOR 000 001 170 154 1
Push-buttons actuators
Signal lamp
Rotary handle
Rotary handle 250A
Bushing
Windows
Bus-bar
Elements
EJB flameproof enclosures
3
2.3.37 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Plugs & receptacles
Contents
Page
GHG51 plastic Ex plugs & receptacles 2.4.1
Roughneck single conductor connectors 2.4.21
Roughneck hazardous multipin 2.4.33
Roughneck heavy industrial multipin 2.4.60
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.4.0
4
2.4.1 EATON’S CROUSE-HINDS SERIES PORTFOLIO
10 A to 125 A
Plastic version for Zone 1 and Zone 21
A good connection
Providing electrical energy there, where it is most
needed – even in hazardous areas for the Zones 1, 2,
21 and 22.
Non-stationary electrical apparatus have generally high
requirements on the energy/power supply. Robust
plugs and receptacles as well as a high chemical
resistance are at the first glance ver\\ iPportant
Electrical reliability is a must not only for all connectivity
products.
A high safety standard, a steady hold and faultless
contacting even under vibration or the effects of an
aggressive atmospheric environment are the basis for
a secure and reliable utilisation.
&($* plugs and receptacles oΊer Pore apart IroP the
proven technolog\\ this product series is defined E\\ its
innovative details )or e[aPple the ver\\ ecient caEle
strain relief or the new coding system of the various
versions offers different solutions for a secure and
problem free utilization in all areas.
-ust to round the product oΊ the user in the norPal
industrial sector becomes exactly the same product
advantages. Robust industrial versions fulfil all
requirements appertaining to mechanical and chemical
dura bility. For the stationary repair power supplying
in hazardous explosive areas, there is a specially
conceived version availaEle that Iulfils all the necessar\\
safety requirements. Used in a module sense,
individual solutions are no problem at all.
The CEAG wall socket for instance can be mounted on
to the pre-installed mounting frame without having to
use tools – installation without a hot work permit.
Apart from the plugs and receptacles for the European
market, we also have plugs and sockets extra for
the US market, which are in accordance to all of the
necessary standards UL and safety protection systems
used there. The available standard range used here,
are the 20 A, 30 A, 60 A and 100 A.
International approvals.
• Nickel-plated contacts
• Low insertion force
• Safety standard IP66 applies also in
the plugged-in state
• Full AC-3 switching ability
• Self-cleaning lamellar contacts, low
transition resistance
• All-pole on/off switching
• Easy plugging
Ex-plugs and receptacles
4
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.4.2
Technical data
Ex-plugs and receptacles acc. to IEC 60309-1/2 16A
Marking accd. to 2014/34/EU Wall socket, plug, couplerffl II 2G / Ex db eb >ia@ IIC / IIB++2 T6
II 2 D Ex IIIC / IIIB T80 Db
)lange socketffl II 2G Ex db eb IIC / IIB++2 Gb
II 2 D Ex tb IIIC Db
EC-7ype Examination Certifi cate Wall socket, plug, coupler: BVS 17 ATEX E 053 X
Flange socket: BVS 15 ATEX E 101 U
,ECEx Certifi cate of Conformity Wall socket, plug, coupler: IECEX BVS 17.0045X
Flange socket: IECEX BVS 15.0088U
EAC (TR) 1EX D E [IA] IIC/IIB T6 GB X
EX TB IIIC T80°C DB X
Permissible ambient temperature -55 rC to + 55 rC
Rated voltage up to 415 V, (3-pole) / 690 V, (4-pole) / 690 V, (5-pole) AC
Rated current 16 A
Frequency up to 400 Hz
Rated making / Rated breaking capacity AC-3 Ue 250 V / Ie 16 A (3-pole)
accd. EN 60947-3 Ue 690 V / Ie 16 A (4-pole)
Ue 500 V / Ie 16 A (5-pole)
External back-up fuse, max. without therm. protection: 16 A
with therm. protection: 35 A gG (rated current 16 A set to)
Protection class I
Degree of protection accd. to EN 60529 IP66
Enclosure colour black
Wall socket
Cable entry 1 x M25 cable gland, 1 x M25 plastic Ex-screw plug or
2 x metal thread M20 with plastic Ex-screw plug
Connecting terminals 2 x 1.5 ȁ 4.0 mmt
Enclosure material Glass-fi bre reinforced polyester
Plug
Cable entry 8 ȁ 18 mm (3-pole) / 8 ȁ 21 mm (4-pole) / 12 ȁ 21 mm (5-pole)
Connecting terminals 1 x 1.0 ȁ 4.0 mmt
Enclosure material Polyamide
Coupler
Cable entry 8 ȁ 19 mm (3-pole) / 8 ȁ 21 mm (4-pole) / 12 ȁ 21 mm (5-pole)
Connecting terminals 1 x 1.5 ȁ 4.0 mmt
Enclosure material Polyamide
Flange socket
Connecting terminals 2 x 1.5 ȁ 4.0 mmt
Enclosure material Polyamide
Plug install protected against higher mechanical risk 4J under -40°C.
Wall socket Flange socket Coupler Plug
16A 3-pole, 4-pole and 5-pole up to 690 V
4
2.4.3 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Plug Coupler Flange socket Wall socket
Ordering details
16A 3-pole, 4-pole and 5-pole up to 690 V
Voltage h Type
Aux.
contact
Cable
entry Weight
Extended temp
IIB+H2 -55 °C up to +45 °C (16 A)
IIC -20 °C up to +55 °C (10 A)
Standard temp
IIC -20 °C up to +55 °C (16 A) Order No.
Type 16A 3pol
110 -130V Wall socket - KU 1.2 kg X GHG5114304R0001
Wall socket - GE 1.2 kg X GHG5114304R0002
Wall socket - GE 1.2 kg X GHG5114304R0102
Wall socket - ME 1.3 kg X GHG5114304R3001
Wall socket - ME 1.3 kg X GHG5114304R3101
Wall socket - GM 1.3 kg X GHG5114304R3003
Wall socket - GM 1.3 kg X GHG5114304R3103
Flange socket - 0.4 kg X GHG5118304R0001
Flange socket - 0.4 kg X GHG5118304R0101
Coupler - 0.7 kg X GHG5113304R0001
Plug 0.35 kg X X GHG5117304R0001
Type 16A 3pol
200-250 V Wall socket - KU 1.2 kg X GHG5114306R0001
Wall socket - GE 1.2 kg X GHG5114306R0002
Wall socket - GE 1.2 kg X GHG5114306R0102
Wall socket - ME 1.3 kg X GHG5114306R3001
Wall socket - ME 1.3 kg X GHG5114306R3101
Wall socket - GM 1.3 kg X GHG5114306R3003
Wall socket - GM 1.3 kg X GHG5114306R3103
Flange socket - 0.4 kg X GHG5118306R0001
Flange socket - 0.4 kg X GHG5118306R0101
Coupler - 0.7 kg X GHG5113306R0001
Plug 0.35 kg X X GHG5117306R0001
Type 16 A 4-pole
200-250 V Wall socket - KU 1.2 kg X GHG5114409R0001
Wall socket - ME 1.3 kg X GHG5114409R3001
Wall socket - ME 1.3 kg X GHG5114409R3101
Wall socket - GM 1.3 kg X GHG5114409R3003
Wall socket - GM 1.3 kg X GHG5114409R3103
Flange socket - 1.0 kg X GHG5118409R0001
Flange socket - 1.0 kg X GHG5118409R0101
Coupler - 1.7 kg X GHG5113409R0001
Plug 0.35 kg X X GHG5117409R0001
380-415V Wall socket - KU 1.2 kg X GHG5114406R0001
Wall socket - ME 1.3 kg X GHG5114406R3001
Wall socket - ME 1.3 kg X GHG5114406R3101
Wall socket - GM 1.3 kg X GHG5114406R3003
Wall socket - GM 1.3 kg X GHG5114406R3103
Flange socket - 1.0 kg X GHG5118406R0001
Flange socket - 1.0 kg X GHG5118406R0101
Coupler - 1.7 kg X GHG5113406R0001
Plug 0.35 kg X X GHG5117406R0001
4
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.4.4
Ordering details
Voltage h Type
Aux.
contact
Cable
entry Weight
Extended temp
IIB+H2 -55 °C up to +45 °C (16 A)
IIC -20 °C up to +55 °C (10 A)
Standard temp
IIC -20 °C up to +55 °C (16 A) Order No.
Type 16A 4pol
480-500V Wall socket - KU 1.2 kg X GHG5114407R0001
Wall socket - ME 1.3 kg X GHG5114407R3001
Wall socket - ME 1.3 kg X GHG5114407R3101
Flange socket - 1.0 kg X GHG5118407R0001
Flange socket - 1.0 kg X GHG5118407R0101
Coupler - 1.7 kg X GHG5113407R0001
Plug 0.35 kg X X GHG5117407R0001
600-690V Wall socket - KU 1.4 kg X GHG5114405R0001
Wall socket - ME 1.5 kg X GHG5114405R3001
Wall socket - ME 1.5 kg X GHG5114405R3101
Flange socket - 1.0 kg X GHG5118405R0001
Flange socket - 1.0 kg X GHG5118405R0101
Coupler - 1.7 kg X GHG5113405R0001
Plug 0.35 kg X X GHG5117405R0001
Type 16A 5pol
200-250V Wall socket - KU 1.2 kg X GHG5114506R0001
380-415V Wall socket - ME 1.3 kg X GHG5114506R3001
Wall socket - ME 1.3 kg X GHG5114506R3101
Wall socket - GM 1.3 kg X GHG5114506R3003
Wall socket - GM 1.3 kg X GHG5114506R3103
Flange socket - 1.0 kg X GHG5118506R0001
Flange socket - 1.0 kg X GHG5118506R0101
Coupler - 1.7 kg X GHG5113506R0001
Plug 0.35 kg X X GHG5117506R0001
Wall socket Flange socket Coupler Plug
16A 3-pole, 4-pole and 5-pole up to 690 V
Other voltage ranges and versions available on request
KU = 1 x plastic cable glands M25, 1 x M25 plastic Ex-screw plug
ME = 2 x metal thread M20
GM = 2 x metal thread M20 with screw plug, with external earth bolt M6 GE = 2x plastic thread M20
without gland/screw plug
4
2.4.5 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Wall socket Flange socket Coupler Plug
Dimension drawing | wiring diagram
16A 3-pole, 4-pole and 5-pole up to 690 V
X = fixing dimensions
Flange socket 3-pole
6
10
82 75
72
65
53
5365
Flange socket 4/5-pole
6
10
83 75
76.5 (4-pole) 84 (5-pole)
86
69.5
69.5 86
Plug 3-pole
76.5 ~192
Plug 4/5-pole
4 pole 76.5
5 pole 84 ~192
Wall socket 3-pole
90
X80 121
11
X115155
223
7
Wall socket 4/5-pole
110
X100 147
11
X135 175
236
7
elop-3relpuoC elop-5/4relpuoC
~279
76,5 (4-polig) 82,5 (5-polig)
90
90
263
72
69
71.5
1 P + N + PE
without
aux. contact
without
aux. contact
with
aux. contact
without
aux. contact
with
aux. contact
PENL1
3P + PE 3P + AUX + PE
PEL3L2L1 13 PE
14
L2L1 L3 N
3P + N + PE 3P + N + AUX + PE
PENL3L2L1 PE13
14
L2L1 L3 N
Assembly dimensions fl tekcosegna flsnoisnemidylbmessA ange socket
X53
Ø63.5 Ø56 X53
M4
8.5
60°
30°
X69,5
Ø83 Ø74 X69,5
M5
Ø10
25° 65°
Dimensions in mm
4
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.4.6
Protective canopy Plug cap GHG 610 1901 R0126
Mounting plates for wall sockets 16 A
Type Application Fixing method Order No.
Size 4 for wall mounting snap on GHG 610 1953 R0126
Size 4 for trellis mounting snap on GHG 610 1953 R0126
Size 4 for pipe mounting snap on GHG 610 1953 R0130
Plug cap for plugs 16 A
Type Order No.
Plug 16 A 3-pole GHG 510 1901 R0001
Plug 16 A 4-pole GHG 510 1901 R0002
Plug 16 A 5-pole GHG 510 1901 R0003
Accessories for mounting plates
Type OU Order No.
Mounting set for pipes 1Ȋ ( 27 - 30 mm) for mounting plates with pipe fixing 10 G+G 610 1953 R0020
Please pay attention that only order units (OU) according to the Ordering Information can be delivered.
Protective canopy for mounting plate
Type Application Order No.
Size 4 for mounting plate size 4, snap on GHG 610 1955 R0107
Dimensions in mm
Mounting plate size 4
for wall/trellis mounting
Mounting plate size 4
for pipe mounting
Protective canopy size 4
237
134.5 27 68 237
134.5
95⎮
129 146
277
16A 3-pole, 4-pole and 5-pole up to 690 V
Accessories
Dimension
4
2.4.7 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Wall socket Flange socket Coupler Plug
Technical data
32 A 4/5-pole up to 690 V
Ex-plugs and receptacles acc. to IEC 60309-1/2
Marking accd. to 2014/34/EU Wall socket, plug, coupler: II 2G / Ex db eb IIC / IIB T5 Gb
II 2 D Ex tb IIIC T80°C Db
Flange socket: II 2G Ex db eb IIC / IIB Gb
II 2 D Ex tb IIIC Db
EC-7ype Examination Certificate Wall socket, plug, coupler: BVS 21 ATEX E 001 X
Flange socket: BVS 20 ATEX E 090 U
,ECEx Certificate of Conformity Wall socket, plug, coupler: IECEx BVS 21.0002X
Flange socket: IECEx BVS 20.0072 U
Marking accd. to IECEx Ex db eb IIC/IIB T5 Gb
Ex tb IIIC T80°C Db
EAC (TR) 1EX d e [ia] IIC/IIB T6 Gb X
Ex tb IIIC T80°C Db X
Permissible ambient temperature Wall socket, plug: IIB -55rC up to +55rC
Wall socket, plug: IIC -45rC up to +55rC
Coupler: IIC -25rC up to +55rC
Flange socket: IIB -55rC up to +80rC
Flange socket: IIC -45rC up to +80rC
Rated voltage up to 690 V (AC)
Rated current 32 A
Frequency up to 400 Hz
Rated making / Rated breaking capacity AC-3 Ue 690 V / Ie 32 A
accd. EN 60947-3
External back up fuse without thermal protection: 35 A
with thermal protection: 50 A gG (rated current 32 A set to)
Protection class I
Degree of protection accd. to EN 60529 IP66
Enclosure colour black
Wall socket
Cable entry/enclosure drilling 1 x M40 cable gland, 1 x M40 plastic Ex-screw plug or
2 x M32 metal thread with 2 plastic Ex-screw plug
Connecting terminals 2 x 4 - 10 mm²
Enclosure material glass-fibre reinforced polyester
Plug
Cable entry Ø 12 - 28 mm
Connecting terminals 2.5 - 6 mm²
Enclosure material Polyamide
Coupler
Cable entry Ø 12 - 28 mm
Connecting terminals 2 x 4 - 10 mm²
Enclosure material Polyamide
Flange socket
Connecting terminals 2 x 4 - 10 mm²
Enclosure material Polyamide
4
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.4.8
Plug Coupler Flange socket Wall socket
Ordering details
32 A 4/5-pole up to 690 V
Voltage h Type Aux. contact Cable entry Weight approx. Order No.
Type 32 A 4-pole
200-250 V Wall socket ȁ KU 2.3 kg GHG 512 4409 R0001
Wall socket ME 2.4 kg GHG 512 4409 R3001
Wall socket GM 2.3 kg GHG 512 4409 R3003
Flange socket 1.0 kg GHG 512 8409 R0001
Coupler 1.55 kg GHG 512 3409 R0001
Plug 0.55 kg GHG 512 7409 R0001
380-415 V Wall socket ȁ KU 2.3 kg GHG 512 4406 R0001
Wall socket ME 2.4 kg GHG 512 4406 R3001
Wall socket yes KH 2.3 kg GHG 512 4406 R0501
Wall socket ȁ GM 2.4 kg GHG 512 4406 R3003
Flange socket 1.0 kg GHG 512 8406 R0001
Coupler 1.55 kg GHG 512 3406 R0001
Plug 0.55 kg GHG 512 7406 R0001
480-500 V Wall socket KU 2.3 kg GHG 512 4407 R0001
Wall socket ME 2.4 kg GHG 512 4407 R3001
Wall socket yes KH 2.3 kg GHG 512 4407 R0501
Flange socket 1.0 kg GHG 512 8407 R0001
Coupler 1.55 kg GHG 512 3407 R0001
Plug 0.55 kg GHG 512 7407 R0001
600-690 V Wall socket KU 1.8 kg GHG 512 4405 R0001
Wall socket ME 2.4 kg GHG 512 4405 R3001
Wall socket yes KH 2.3 kg GHG 512 4405 R0501
Flange socket 1.0 kg GHG 512 8405 R0001
Coupler 1.55 kg GHG 512 3405 R0001
Plug 0.55kg GHG 512 7405 R0001
Type 32 A 5-pole
200-250 V Wall socket KU 2.3 kg GHG 512 4506 R0001
380-415 V Wall socket ME 2.4 kg GHG 512 4506 R3001
Wall socket yes KH 2.3 kg GHG 512 4506 R0501
Wall socket GM 2.4 kg GHG 512 4506 R3003
Flange socket 1.0 kg GHG 512 8506 R0001
Coupler 1.6 kg GHG 512 3506 R0001
Plug 0.6 kg GHG 512 7506 R0001
Other voltage ranges and versions available on request
KU = 1 x plastic cable glands M40, 1 x M40 plastic Ex-screw plug
KH = 1 x plastic cable glands M40, 1 x plastic cable glands M25, with aux. contact
ME = 2 x metal thread M32 with plastic Ex-screw plug
GM = 2 x metal thread M32 with screw plug, with external earth bolt M6
9 h
6 h
7 h
5 h
6 h
4
2.4.9 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Wall socket Flange socket Coupler Plug
32A 4-pole up to 690 V | 32A 5-pole up to 415 V
Dimension drawing | wiring diagram
Wall socket 4-pole
120 166
11
X170 205
285
7
X110
Wall socket 5-pole
120 168
11
205
293
7
X170
X110
X = fixing dimensions
Flange socket 4-pole
6 10
141 86
95
86
69.5
69.586
Flange socket 5-pole
6 10
142 91
100
86
69.5
69.586
Plug 4-pole 95
~249
Plug 5-pole 100
~249
Coupler 4-pole ~339
95 90
90
Coupler 5-pole
~345
90100
90
3P + PE 3P + AUX + PE
PEL3L2L1 13 P
14
L2L1 L3 N
with
aux. contact
without
aux. contact
3P + N + PE 3P + N + AUX + PE
PENL3L2L1
without
aux. contact
with
aux. contact
PE13
14
L2L1 L3 N
tekcosegnaflsnoisnemidylbmessA tekcosegnaflsnoisnemidylbmessA
X69,5
Ø83 Ø78 X69,5
M5 Ø8.5 Ø16
R3
72,4
110°
32°
56°
34°
X69,5
Ø83 Ø78 X69,5
M5 Ø8.5 Ø16
R3
72,4
110°
32°
56°
34°
Dimensions in mm
4
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.4.10
Mounting plates for wall sockets 32 A
Type Application Fixing method Order No.
Size 5 for wall mounting snap on GHG 610 1953 R0128
Size 5 for trellis mounting snap on GHG 610 1953 R0128
Size 5 for pipe mounting snap on GHG 610 1953 R0132
Plug cap for plugs 32 A
Type Order No.
Plug 32 A 3-pole/4-pole GHG 510 1901 R0004
Plug 32 A 5-pole GHG 510 1901 R0005
Accessories for mounting plates
Type OU Order No.
Mounting set for pipes 1Ȋ ( 27 - 30 mm) for mounting plates with pipe fixing 10 G+G 610 1953 R0020
Please pay attention that only order units (OU) according to the Ordering Information can be delivered.
Protective canopy for mounting plate
Type Application Order No.
Size 5 for mounting plate size 5, snap on GHG 610 1955 R0108
Dimensions in mm
Mounting plate size 5
for wall/trellis mounting
Mounting plate size 5
for pipe mounting
Protective canopy size 5
265
180 27 68 265
180
95⎮
174 171
305
32A 4-pole up to 690 V | 32A 5-pole up to 415 V
Accessories
Dimension
Protective canopy Plug cap GHG 610 1901 R0128
4
2.4.11 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Plug
Technical data
Ex-plugs and receptacles acc. to IEC 60309-1/2 up to 690 V
Marking accd. to 2014/34/EU II 2G Ex db eb IIC/IIB T5 Gb
II 2D Ex tb IIIC T80°C Db
Marking accd. to 2014/34/EU Ex db eb IIC/IIB T5 Gb
Ex tb IIIC T80°C Db
EC-7ype Examination Certificate BVS 17 ATEX E 073 X
,ECEx Certificate of Conformity IECEx BVS 17.0062X
Permissible ambient temperature -55 rC to + 55 rC 3)
Rated voltage 690 V AC (4-pole) / 500V AC (5-pole)
Rated current 63 A
Frequency up to 400 Hz
Rated making / Rated breaking capacity Ue 690 V / Ie 63 A
AC-3 accd. EN 60947-3
External back up fuse without therm. protection: 63 A
with therm. protection: 80 A gG (rated current 63 A set to)
Protection class I
Degree of protection accd. to EN 60529 IP66
Enclosure colour black
Wall socket
Cable entry/enclosure drilling 1 x M50 cable gland, 1 x M50 plastic Ex-screw plug or
2 x M40 metal thread with plastic Ex-screw plug
Connecting terminals 2 x 4 - 25 mm² / with cable lug1) 1 x 35 mm²
Enclosure material glass-fibre reinforced polyester
Plug
Cable gland Ø 19 - 34 mm
Connecting terminals 1 x 4 - 16 mm² / 1 x 25 mm² with pin cable lug2)
Enclosure material Polyamide
Wall socket
63 A 4/5-pole up to 690 V
1) use supplied cable lugs
2) see accessories
3) Wall socket install protected against higher mechanical risk 4J under -40°C.
4
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.4.12
Wall socket Plug
63 A 4/5-pole up to 690 V
Ordering details
Voltage h
Aux.
contact
Cable
entry Type
IIB / IIC
low temp -55 °C
up to +40/+55 °C
IIC
high temp -20 °C
up to +55 °C Weight approx. Order No.
Type 63 A 4-pole
200-250 V - KU Wall socket X 8.1 kg GHG514 4409 R0001
- ME Wall socket X 8.2 kg GHG514 4409 R3001
- ME Wall socket X 8.2 kg GHG514 4409 R3101
Plug X X 0.9 kg GHG514 7409 R0001
380-415 V - KU Wall socket X 8.1 kg GHG514 4406 R0001
- ME Wall socket X 8.2 kg GHG514 4406 R3001
- ME Wall socket X 8.2 kg GHG514 4406 R3101
- GM Wall socket X 8.2 kg GHG514 4406 R3003
- GM Wall socket X 8.2 kg GHG514 4406 R3103
Plug X X 0.9 kg GHG514 7406 R0001
480-500 V - KU Wall socket X 8.1 kg GHG514 4407 R0001
- ME Wall socket X 8.2 kg GHG514 4407 R3001
- ME Wall socket X 8.2 kg GHG514 4407 R3101
- GM Wall socket X 8.2 kg GHG514 4407 R3003
- GM Wall socket X 8.2 kg GHG514 4407 R3103
Plug X X 0.9 kg GHG514 7407 R0001
600-690 - KU Wall socket X 8.1 kg GHG514 4405 R0001
- ME Wall socket X 8.2 kg GHG514 4405 R3002
- ME Wall socket X 8.2 kg GHG514 4405 R3102
Plug X X 0.9 kg GHG514 7405 R0001
Type 63 A 5-pole
200-250 V - KU Wall socket X 8.1 kg GHG514 4506 R0001
380-415 V - ME Wall socket X 8.2 kg GHG514 4506 R3001
- ME Wall socket X GHG514 4506 R3101
- GM Wall socket X 8.2 kg GHG514 4506 R3006
- GM Wall socket X 8.2 kg GHG514 4506 R3106
Plug X X 0.9 kg GHG514 7506 R0001
other voltage ranges and versions, e.g. with aux. contact, on request
KU = 1 x plastic cable glands M40 cable gland, 1 x M40 plastic Ex-screw plug
ME = 2 x metal thread M32 with plastic Ex-screw plug
9
6
7
5
6
5
6
4
2.4.13 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Plug Wall socket
Dimensions in mm
Wall socket 4/5-pole
Plug 4/5-pole X = Fixing dimensions
200
X184
226
475
X276
370
9
10
Ø 110
approx. 272
3P + PE 3P + AUX + PE
1L 2L 3L EP 31 EP
14
1L 2L 3L
with
auxiliary contact
without
auxiliary contact
3P + N + PE 3P + N + AUX + PE
1L 2L 3L N EP
without
auxiliary contact
with
auxiliary contact
31 EP
14
1L 2L L3 N
4-pole 5-pole
63A 4- and 5-pole up to 690 V
Dimension drawing | wiring diagram
4
EATON’S CROUSE-HINDS SERIES PORTFOLIO 2.4.14
Wall socket Plug
Ex-plugs and receptacles acc. to IEC 60309-1/2
Marking accd. to 2014/34/EU II 2 G Ex de IIC T6 / II 2 D Ex tD A21 IP66 T80 °C
EC-7ype Examination Certificate PTB 01 ATEX 1069
,ECEx Certificate of Conformity IECEx BKI 04.0005
Marking accd. to IECEx Ex ed IIC T6
Permissible ambient temperature -20 rC to + 40 rC1)
Rated voltage 690 V
Rated current 125 A
Frequency up to 400 Hz
Rated making / Rated breaking capacity Ue 690 V / Ie 125 A
AC-3 accd. EN 60947-3
External back up fuse without therm. protection: 125 A
with therm. protection: 160 A gG (rated current 125 A set to)
Protection class I
Degree of protection accd. to EN 60529 IP66
Enclosure colour black
Wall socket
Cable entry/enclosure drilling 1 x M63 cable gland, 1 x M63 plastic Ex-screw plug or
2 x M50 metal thread with 2 plastic Ex-screw plug
Connecting terminals 2 x 4 - 70 mm² / with ring cable lug2) 1 x 120 mm²
Enclosure material glass-fibre reinforced polyester
Plug
Cable entry Ø 31 - 55 mm
Connecting terminals 1 x 4 - 35 mm² / with pin cable lug3) 1 x 50 mm²
Enclosure material Polyamide
1) extended temperature range on request
2) use supplied cable lugs
3) see accessories
125 A 4/5-pole up to 690 V
Technical data
4
2.4.15 EATON’S CROUSE-HINDS SERIES PORTFOLIO
Plug cap Plug Wall socket
125A 4- and 5-pole up to 690 V
Ordering information
Accessories
Type OU Order No.
Plug cap 4-pole/5-pole 1 GHG 510 1901 R0007
Set of ring cable lug 70/120 mm2
for wall socket (Me 4 + 1 pcs.) 1 G+G 260 1911 R0004
Other voltage ranges and versions available on request
KU = 1 x plastic cable glands M63 for Ø 27-48 mm, 1 x M40 plastic Ex-screw plug
KH = 1 x plastic cable glands M63 for Ø 27-48 mm,
1 x plastic cable glands M25 for Ø 8 - 17 mm, with aux. contact
ME = 2 x metal thread M50 with plastic Ex-screw plug
GM = 2 x metal thread M50 with screw plug, with external earth bolt M8
Voltage h Type Auxiliary contact Cable entries Weight approx. Order No.
Type 125 A 4-pole
200-250 V Wall socket ȁ KU 12.3 kg G+G 515 4409 R0001
Wall socket ȁ ME 12.5 kg G+G 515 4409 R3001
Wall socket yes KH 12.5 kg GHG 515 4409 R0501
Plug 0.9 kg GHG 515 7409 R0001
9h
380-415 V Wall socket ȁ KU 12.3 kg G+G 515 4406 R0001
Wall socket ȁ ME 12.5 kg G+G 515 4406 R3001
Wall socket yes KH 12.5 kg GHG 515 4406 R0501
Wall socket ȁ GM 8.2 kg G+G 515 4406 R3003
6h Plug 0.9 kg GHG 515 7406 R0001
480-500 V Wall socket ȁ KU 12.3 kg G+G 515 4407 R0001
Wall socket ȁ ME 12.5 kg G+G 515 4407 R3001
Wall socket yes KH 12.5 kg GHG 515 4407 R0501
Wall socket ȁ GM 8.2 kg G+G 515 4407 R3002
7h Plug 0.9 kg GHG 515 7407 R0001
600-690 V Wall socket ȁ KU 12.3 kg G+G 515 4405 R0001
Wall socket ȁ ME 12.5 kg G+G 515 4405 R3001
Wall socket yes KH 12.5 kg GHG 515 4405 R0501
Wall socket ȁ GM 8.2 kg G+G 515 4405 R3002
5h Plug 0.9 kg GHG 515 7405 R0001
Type 125 A 5-pole
200-250 V Wall socket ȁ KU 13.0 kg G+G 515 4506 R0001
380-415 V Wall socket ȁ ME 13.2 kg G+G 515 4506 R3001
Wall socket yes KH 13.2 kg GHG 515 4506 R0501
Wall socket ȁ GM 8.2 kg G+G 515 4506 R3005
6h Plug 1.2 kg GHG 515 7506 R0001