CDT6-2TDual Delay Type Time Relay
| Technical parameters | |||
| CDT6-2T | |||
| Function 0577-6731370 | Dual-set power-on delay 技人 | ||
| Power terminal | A1-A2 | ||
| W (AC/DC12V-240V) | AC/DC12-240V(50-60Hz) | ||
| Power consumption | AC0.09-3VA/DC0.05-1.7W | ||
| M (AC220V) | AC0.09-3VA/DC0.05-1.7W | ||
| Power consumption | ACmax.6VA/1.9W | ||
| Allowablefluctuationrangeof power supply | |||
| Powerindicator | -15%;+10% Gren LED | ||
| Delay range | 0.1 seconds-10 daysnormallyopen,ormally closed | ||
| Setting method | knob | ||
| Setting accuracy | 10% | ||
| Repeatability | 0.2% | ||
| Temperaturefluctuationerror | 0.05%℃ at=20°℃(0.05%°F, at=68F)→| www.jrciS.com | ||
| Output contact parameters | Number of contacts | 0577-62733721 2 sets of conversion contacts | |
| 10A | 210A250VAC/24VDC | ||
| 16A | 2*16A250VAC/24VDC | ||
| Minimumswitchingpower | 500mW | ||
| Outputrelayindication | Red LED | ||
| Mechanical life | 1×10 | ||
| Electrical life(resistive load) | 1×105 | ||
| Resettime | Maximum200ms | ||
| Operatingambienttemperature | -20°℃-+55℃ | ||
| Seorand rasportombet | -35°℃-+75°℃ | ||
| Installationmethod | 35mm card ralinstallation | ||
| Protection level | IP20 | ||
| Installation location | Arbitrary | ||
| Installation altitude | ≤2000m | ||
| Poto 品牌设计.m | |||
| Wiring ability | 1x2.5mm²or2x1.5mm²0.4N·m | ||
| Dimensions | 90mm×18mm×65mm | ||
| Weight | 80g | ||
Function diagramw
Wiring diagram
Shape and size (mm)
CDT6-S cycle Delay Type Time Relay
Application
Usedforcycledelaycontrol,periodicpower-on,lighting control, andheatingcontrolofanelectricalcircuit.
Features
ThereareseparatedelaysettingsforONandOFF,anddifferent delaytimes can be set.
Ultra-wide delayrange,0.1seconds-100days canbe set(10gears).
Differentworking modescanbe switched by shorting S-A1.
IthasAC/DC12V-240Vultra-wideoperatingvoltage specifications to choosefrom.
TheworkingstatusoftherelayisindicatedbyanLEDindicator.
Utra-small size,only18mmwidth, 35mm card rail installation.
Product selection
| No | Item | Code | Description |
| Productname | CDT6 | Clamp railtype timerelay | |
| ② | Functioncode | S | Cycledelaytypetimerelay(loopdelay) |
| Outputhe gumberof | 1 | Group1conversion | |
| 2 | Group2conversion | ||
| Output contact | 10 | Output contact 10A | |
| 16 | Outputcontact16A | ||
| 技 # | 人品牌设 Rated operating voltage | ww .jrcis. | AC/DC12V-240V |
| M | AC220V | ||
| A-Zlettercombination | Custom voltage |
CDT6-S cycle Delay Type Time Relay
| Technical parameters | |||||
| CDT6-S1 | CDT6-S2 | ||||
| H设计 1 0577673721 | Cycle delay | 技人 | |||
| Power terminal | A1-A2 | ||||
| Reted ontrol ower | AC/DC12-240V(50-60Hz) | ||||
| Power consumption | W (AC/DC12V-240V) | AC0.09-3VA/DC0.05-1.7W | |||
| M (AC220V) | AC220V(50-60Hz) | ||||
| ACmax.6VA/1.3W | ACmax.6VA/1.9W | ||||
| Power consumption Allowable fluctuationrangeof power supply | -15%;+10% | ||||
| Powerindicator | Green LED | ||||
| Delay range | 0.1 seconds-100 days | ||||
| Settingmethod | knob | ||||
| Setting accuracy | 10% | ||||
| Repeatability | 0.2% | ||||
| Temperaturefluctuationerror | 0.05%Cat=20℃(0.05%F,a=68F www.jrcis.com | ||||
| porut contact | Number of contacts | 1setofconversion contacts | 2 sets of conversion contacts | ||
| 10A | 1*10A 250VAC/24VDC | 2*10A250VAC/24VDC | |||
| 16A | 1*16A250VAC/24VDC | 2*16A250VAC/24VDC | |||
| Minimumswitchingpower | 500mW | ||||
| Output relay indication | Red LED | ||||
| Mechanical life | 1x10 | ||||
| Electricallife(resistive load) | 1×105 | ||||
| Reset time | Maximum 200ms | ||||
| Operating ambienttemperature | -20°℃~+55°℃ | ||||
| Seorgand rasprtatonambent | -35℃~+75°℃ | ||||
| Installationmethod | 35mmcard railinstallation | ||||
| Protection level | IP20 | ||||
| Installation location | Arbitrary | ||||
| Installation altitude | ≤2000m | ||||
| Polutonle品卑设计 | www.2rcis.com 2 | ||||
| Wiringabity | 1x2.5mm²or2x×1.5mm²0.4N·m | ||||
| Dimensions | 90mm×18mmx65mm | ||||
| Weight | 67g 80g | ||||
CDT6-S Cycle Delay Type Time Relay
Function diagramw
Wiring diagram
Shape and size(mm)
CDT6-P Delay Pulse Type Time Relay
CEAUS
Application
Used to delay and generate apulse,which isused to delay a certainloadforaperiodoftime.
Features
Separate delaytime andpulse widthsettings,differentdelay times can be set.
Ultra-wide delayrange,0.1 seconds-100days canbe set(10gears)
The delay timecanberesetbyshortingS-A1.
It hasAC/DC12V-240Vultra-wide operatingvoltagespecifications to choose from.
Theworking statusof therelayisindicatedby anLEDindicator.
Ultra-smallsize,only18mmwidth,35mmcardrailinstallation.
Product selection
| No | Item | Code | Description |
| Productname | CDT6 | Clamp rail type timerelay | |
| ② | Functioncode | P | Time delaypulse typetimerelay(delaypulse) |
| Outputthe gumber of | 1 | Group1conversion | |
| 2 | Group2conversion | ||
| Output contact | 10 | Output contact10A | |
| 16 | Output contact16A | ||
| 技 # | 人品牌设 Ratedoperating voltage | WM v.jrcis. | AC220V |
| W | AC/DC12V-240V | ||
| A-Zlettercombination | Custom voltage |
CDT6-P Delay Pulse Type Time Relay
| Technicalparameters | |||||
| CDT6-P1 | CDT6-P2 | ||||
| 057-62733721 Function交 | Delay pulse output | 技人 | |||
| Power terminal | A1-A2 | ||||
| W | AC/DC12-240V(50-60Hz) | ||||
| Power consumption | (AC/DC12V-240V) | AC0.09-3VA/DC0.05-1.7W | |||
| Retel otrol ower | M(AC220V) | AC 220V(50-60Hz) | |||
| Power consumption | ACmax.6VA/1.3W | ACmax.6VA/1.9W | |||
| Aloable flctuatorane o powver | -15%;+10% | ||||
| Powerindicator | GreenLED | ||||
| Delay range | 0.1 seconds -100 days | ||||
| Settingmethod | knob | ||||
| Seting accuracy | 10% | ||||
| Repeatability | 0.2% | ||||
| Temperaturefluctuationerror | 0.05%C,at=20°C(0.05%F,at=68°F)| www.jrcis.com | ||||
| Output contact parameters | Numberof contacts | 1setof conversion contacts | 2 setsof conversion contacts | ||
| 10A | 1*10A250VAC/24VDC | 2*10A250VAC/24VDC | |||
| 16A | 1*16A250VAC/24VDC | 2*16A250VAC/24VDC | |||
| Minimumswitchingpower | 500mW | ||||
| Outputrelay indication | Red LED | ||||
| Mechanical life | 1x10 | ||||
| Electrical life(resistive load) | 1×105 | ||||
| Resettime | Maximum200ms | ||||
| Operating ambienttemperature | -20°C~+55℃ | ||||
| Storand rasratonmbient | -35°℃~+75℃ | ||||
| Installationmethod | 35mmcard rail installtion | ||||
| Protection level | IP20 | ||||
| Installation location | Arbirary | ||||
| Installation altitude | ≤2000m | ||||
| Polutonleve品牌设计 | cis.com 2 0577-62733721 | ||||
| Wiring ability | 1x2.5mm²or2x1.5mm²0.4N·m | ||||
| Dimensions | 90mm×18mmx65mm | ||||
| Weight | 67g 80g | ||||
Function diagramw
Wiring diagram
Shape and size (mm)
CDT6-ST star-Delta Relay Time Relay
Application
Itisspeciallyusedformotorstartrianglestart-upcontrol,which can greatly simplifytheelectricalcircuit,facilitatewiring and reducecosts.
Features
t1:The start-up delayrange of 0.1s-10min canbe set(knob setting).
t2:Theconversion time is0.1s-1s can be set (knob setting). WithAC220,AC380,AC/DC12V-240Vultra-wideoperating voltage specifications areoptional.
Theworking statusof therelay isindicatedby anLED indicator. Ultra-small size,only 78mm width, 35mm card rail installation.
Product selection
| No | Item | Code | Description |
| Productname | CDT6 | Clamp railtypetimerelay | |
| ② | Functioncode | ST | Stardelta starttimerelay(startriangle startdelay) |
| Output thenumber of contact groups | 2 | Group2conversion | |
| Output contact | 10 | Output contact10A | |
| 16 | Output contact16A | ||
| 品瑰设 Rated operating voltage | M | AC220V | |
| 八 W jrcis. | AC/DC12V-240V | ||
| H | AC380V | ||
| A-Zlettercombination | Custom voltage |
CDT6-ST star-Delta Relay Time Relay
| Technical parameters | |||
| CDT6-ST | |||
| Function 0577-62733721 | Star Triangle start delay 技人品 | ||
| Power terminal | A1-A2 | ||
| Rated control power supplyvoltage | W (AC/DC12V-240V) | AC/DC12-240V(50-60Hz) | |
| Powerconsumption | M(AC220V) | AC 0.3-2VA/DC 0.1-1.2W | |
| Ratedcontrolpower supplyvoltage | AC220V,AC380V(50-60Hz) | ||
| Power consumption | H(AC380V) | ACmax.6VA/1.3W | |
| Allowable fluctuationrange of powersupply | -15%+10% | ||
| Power indicator | Green LED | ||
| Delay range | Start-updelay:0.1seconds-10minutes,conversion delay:0.1s-1s | ||
| Setting method | knob | ||
| Setting accuracy | 10% | ||
| Repeatability | 0.2% | ||
| Temperaturefluctuation error | 0.05%/°℃,at=20°C(0.05%°F,at=68°F) | ||
| Output contact parameters | Number of contacts | 057 -62733721 2setsofconversion contacts | |
| 10A | 2*10A250VAC/24VDC | ||
| 16A | 2*16A250VAC/24VDC | ||
| Minimum switchingpower | 500mW | ||
| Outputrelayindication | Red LED | ||
| Mechanical life | 1x10 | ||
| Electrical life(resistive load) | 1x105 | ||
| Resettime | Maximum200ms | ||
| Operating ambient temperature | -20°C-+55℃ | ||
| Storageandtransportationambienttemperature | -35℃~+75°℃ | ||
| Installationmethod | 35mmcardrail installation | ||
| Protection level | IP20 | ||
| Installation location | Arbitrary | ||
| Installation altitude | ≤2000m | ||
| Polutiontevel品卑设计| wwircis.c | 2 | ||
| Wiring ability | 1x2.5mm²or2×1.5mm²0.4N·m | ||
| Dimensions | 90mm×18mm×65mm | ||
| Weight | 80g | ||
Function diagramw
Wiringdiagram
Shape and size (mm)
CCES
Application
Usedforcorridor,corridor,hall,bathroomlightingdelaycontrol.
Features
Has threemodesof operation: ON:The output contact remains ON.AUTO:Automatic delay control,OFF:The output contactremainsOFF L-3canbe connectedwith neon light switch. Delayrange 0.5-20min can be set (knob setting). Relay operating statusisindicatedbyLEDindicator. Utra-small size,only18mmwidth35mmcardrailmount.
Productselection
| No | Item | Description |
| CDT6seriestimerelay | ||
| ② | Corridordelayswitch | |
| Output thenumber of contact groups | 1:Group1conversion | |
| Output contact | 16:Output contact16A |
Technicalparameters
| CDT6-LS | |
| Function | Corridordelay switch |
| Powerterminal | L-N |
| Ratedcontrolpowersupplyvoltage | AC220V(50-60Hz) |
| 0577-62733721 Power consumption片军反T | ACmax.6VA-1.3W |
| Allowablefluctuationrangeofpowersupply | -15%+10% |
| Powerindicator | GreenLED |
| Delay range | AUTO:0.5-20minONOFF |
Technicalparameters
| www.jrcis.com | CDT6-LS |
| Settingmethod 10577-62733721 | knob |
| Setting accuracy | 10% |
| Repeatability | 0.2% |
| Neon connection | Yes(N-3or L-3) |
| Maximumnumberofneon connections | 230V.up to75PCS(about0.68mA/230VACat neon current) |
| Temperaturefluctuation error | 0.05%/℃,at=20°℃ |
| Output contact parameters | 2setsof conversioncontacts |
| 16A/AC1 | |
| 250VAC/24VDC | |
| Minimum switchingpower | 500mW |
| Outputrelayindication | Red LED |
| Mechanical life | 1×10² |
| Electrical life(resistive load) | 1×105 |
| Resettime | 技人 www.jrcis.com Maximum200msi |
| Operatingambienttemperature | -20°℃~+55℃ |
| Storageand transportationambienttemperature | -35°℃~+75℃ |
| Installationmethod | 35mmcardrailinstalltion |
| Protectionlevel | IP20 |
| Installation location | Arbitrary |
| Installationaltitude | ≤2000m |
| Pollution level | 2 |
| Wiring ability | 1x2.5mm²or2x1.5mm²0.4N-m |
| Dimensions | 90mmx18mmx65mm |
| Weight | 61g |
| Meet the standard | GB/T14048.5,EC60947-5-1EC60669-2-3,EN61812-1 |
Function diagramw
Wiring diagram
Load type
| 正 | ||||||
| 正 | ||||||
| 2000W | 2000W | 1000W | 900W(125uF) | 400W | 300W | |
Application example
Shape and size (mm)
CDA6 AC Current Monitoring Relay
Application
Elevatoroverloadmonitoring,lightloadmonitoring.
Single-phase motormonitoring currentmonitoring.
Currentoverload/under load indicationandprotection.
Features
Theactiondelaytimeisadjustablefrom0.1s to10stoavoid peakcurrent.
Thepower-updelaytime isadjustablefrom0.1sto10stoavoid thestart-upcurrentofthemotorload.
6-speedcurrentspecificationsareoptional.
Built-inisolated currenttransformer,and at the same time,an externalcurrenttransformercanbeconnectedtoexpandthe monitoring currentrange.
Theworkingpowersupplyvoltage isAC85-240v.
Theworkingstatusof therelayisindicatedby anLEDindicator.
UItra-small size,only 18mmwidth, 35mm card rail installation.
Product selection
| No | Item | Code | Description |
| Productname | CDA6 | Voltagemonitoringrelay | |
| Function code | 1 | Overcurrent protection | |
| 2 | Undercurrentprotection | ||
| 3 | Over/undercurrent protection | ||
| 4 | Overcurrentprotection | ||
| Output contact | 10 | 10A Output contact10A | |
| 16 | 16A Output contact16A | ||
| Current detectionrange LOh车位 | A05 | 0.05A-0.5A | |
| A1 | 0.1A-1A | ||
| A2 | 0.2A-2A | ||
| 5A5 6273372 | 0.5-5A | ||
| A8 | 0.8-8A | ||
| A16 | 1.6A-16A |
CDA6 AC Current Monitoring Relay
| Technical parameters | ||||||||
| CDA6-1 | CDA6-2 | CDA6-3 Over/under current protection | CDA6-4 Overcurrent protection | |||||
| Overcurrentprotection|Under-currentprotection | ||||||||
| Power terminal | A1-A2 | |||||||
| Rated supply voltage | AC85-240V | |||||||
| Rated power frequency | 50/60Hz,0 | |||||||
| Power consumption | max25VA | |||||||
| Allowablefluctuationrangeofpower supply | -15%;+10% | |||||||
| Current setting range | 0.05A-0.5A/0.1A-1A/0.2A-2A/0.5A-5A/0.8A-8A/1.6A-16A | |||||||
| Measuring currentfrequency | AC50HZ | |||||||
| Maximum passing current | 1A/2A/5A/8A/12A/22A | |||||||
| Current settingmethod | Knob setting | |||||||
| Action delay time | 0.1s~10 s | |||||||
| Power indicator | GreenLED | |||||||
| Setting accuracy Currentmeasurementaccuracy | 10% | |||||||
| Temperaturefluctuationerror | 5%(0.05-0.5A为10%) | |||||||
| Hysteresis value Output contact parameters | 5% | |||||||
| 10A | 2*10A250VAC/24VDC | |||||||
| Minimum switchingpower | 16A | 2*16A250VAC/24VDC | ||||||
| 500mW | ||||||||
| Outputrelayindication | Red LED | |||||||
| Mechanical life | 1×107 | |||||||
| Electrical life(resistive load) Operating ambienttemperature | 1x105 | |||||||
| Seorand transprtatonabent | -20°℃~+55°℃ | |||||||
| Installationmethod | -35℃~+75℃ | |||||||
| Protection level | 35mmcardrail installation | |||||||
| Installation location | IP20 | |||||||
| Arbitrary | ||||||||
| Instalation atitud号卑设计 | www.jrcis.com ≤2000m | |||||||
| Pollution level | 2 | |||||||
| Wiring abity | 1x2.5mm²or2×1.5mm²0.8N·m | |||||||
| Dimensions Weight | 90mmx18mmx65mm 67g | |||||||
CDA6 AC Current Monitoring Relay
Function diagramw
Wiring diagram
Panel diagram
Shape and size(mm)
CDA6-516 Current Monitoring Relay (Through core type) ④ CEUS
Application
Electricalequipmentovercurrent and undercurrentmonitoring
Features
Through thecoredesign,noneed todisconnect thecurrent circuit,through the coreinstallationiseasytouse The jumper can set theover/undercurrent monitoringmode SpecificationswithAC/DCgeneraldetectionareoptional Usingisolated currenttransformer,while theexternalcurrent transformercanexpandthemonitoring currentrange Working power supply voltageAC/Dc85V-240V Relay operating statusisindicatedbyLEDindicator UItra-small size,only18mmwidth,35mmcardrailmounting
Model designation
| No | Item | Description | |
| CDA6series currentmonitoring relay | |||
| Designsequencenumber | |||
| ③ | Function code | Designation | Function description |
| A | ACdetectiontype | ||
| B | AC-DCdetectiontype | ||
Technicalparameters
| CDA6-516 | |
| Feature | ACdetection type |
| Powerterminal | A1-A2 |
| Rated supply voltageh军役l十|0577-62733721 | AC/DC85V-240V |
| Rated power frequency | 50/60Hz,0 |
| Powerconsumption | Max25VA |
| Powersupplyallowed fluctuationrange | -15%;+10% |
| Technicalparameters | |
| 2免i凸i+|www.jrcis.com | CDA6-516 |
| Current stting range | 2A-20A |
| Measuring current frequency | AC50Hz |
| Current setting mode | knob |
| Actiondelay time | 0.1s-10s |
| Power indicatorlight | GreenLED |
| Setting accuracy | 10% |
| Currentmeasurementaccuracy | 5% |
| Temperaturefluctuationerror | |
| Lagvalue | 5% |
| Exportation | 1xSPDT |
| 10A/AC1 | |
| 技人250VAC/24VDC文 0577-62733721 | |
| Minimum switchingpower | 500mW |
| Outputrelayindication | Red LED |
| Mechanical life | 1×10 |
| Electrical life | 1x105 |
| Operatingambienttemperature | -20°℃~+55°℃C |
| Storageand transportationambient temperature | -35°℃-+75℃ |
| Installationmode | 35mmcardrailinstallation |
| Class of protection | IP20 |
| Installationposition | Arbitrary |
| Installationelevation | ≤2000m |
| Pollution level | 2 |
| Wiring capacity | 1x2.5mm²or 2x1.5mm²0.8N·m |
| www.jrcis.com 0577-62733721 Overalldimension | 90mmx18mmx86mm |
| Weight | 75g |
| Meet the standard | GB/T14048.5,IEC60947-5-1,IEC60669-2-3,EN61812-1 |
CDA6-516 current Monitoring Relay (Through core type) ④ CE A cus
Function diagramw
Wiring diagram
thr currentlessthan2A,lt canbe done multiple timesthrough the heart.
Panel diagram
Shape and size (mm)
技人品牌设计
CDB6 SensitivityAdjustableLight Control Switch
Application
Usedforcorridor,outdoorlightboxautmaticlighting.
For devices thatneed tobeturnedon automaticallyatnight.
Features
Lightsensitivity(illuminance)canbeadjusted asneeded.
Built-in light detection sensor.
Canbesettoworkinon-auto-offmode.
Anexternal switchcanbeused toturnoff theoutput.
Workingpower supplyvoltageAC110V-240v.
TheworkingstatusisindicatedbyLEDindicator.
Ultra-small size,only18mmwidth35mmcardrailmounting.
Accessory
Productselection
| No | Item | Description | |
| # | CDB6serieslight-controlledswitch | ||
| Function code | Designation | Function description | |
| 1 | 2-pole liquid levelmonitoring | ||
| 2 | 1or2levelmonitoring | ||
| Output the number of contact groups | Group1conversion | ||
| Outputcontact | Output contact16A | ||
Technicalparameters
| CDB6-1116 | |
| Feature | Light-controlled switch |
| Powerterminal 光瑰设计 www.jrcis.cor | L-N |
| Rated supplyvoltage | AC110V-240V |
| Rated powerfrequency | 50/60Hz |
| Powerconsumption | Max2VA |
| Powerupplyallwedfluctuationrange | -15%;+10% |
CDB6 SensitivityAdjustableLight Control Switch
Technicalparameters
| UASi www.jrcis.com | CDB6-1116 |
| 733721 Sensitivity adjustmentrange | About1-100Lx |
| Working mode | On-auto off can be set |
| Powerindicatorlight | GreenLED |
| Sensor detectionerror | ±35% |
| Actiondelaytime | 2min |
| Probe lead length | Max50m |
| Outputcontact parameters | 1xSPST |
| 16A/AC1 | |
| 250VAC/24VDC | |
| Minimum switchingpower | 500mW |
| Outputrelayindication | Red LED |
| Mechanical life | 1×10 |
| Electrical life | 1x105 www.ircis.com |
| Operating ambient temperature | 10577-62733721 -20°℃~+55°℃ |
| Storageand transportationambient temperature | -35°℃~+75°℃ |
| Installationmode | 35mmcardrailinstallation |
| Class of protection | IP20 |
| Installationposition | Arbitrary |
| Installationelevation | ≤2000m |
| Pollution level | 2 |
| Wiring capacity | 1x2.5mm²or2x1.5mm²0.8N·m |
| Overall dimension | 90mm×18mmx65mm |
| Weight | 62g |
| Meet the standard | GB/T 14048.5,EN60255-1 |
Function diagramw
CDB6 SensitivityAdjustable Light Control Switch
Wiring diagram
Note:fitisntecessarytoconnecttheclosecontrolbuttonexternallyteminalcanbeleftunconnected
Panel diagram
Shape and size (mm)
CEAUS
Features
Fourworkingmodesareoptional,and the ambient temperature andhumiditythresholdscan be set.
Capacitive humidity sensor,low power consumption, stable performance;
Passive relay outputcan be used to drive cooling fan,TEC, heating wire and other devices;
Theworkingstatusof therelayisindicatedby theLEDindicator;
WorkingpowersupplyvoltageAC85-240v;
Ultra-small size,only 78mm width, 35mm card rail installation;
Applicable tocontrol thetemperatureandhumidityrangeof power distribution cabinets;
Placard
| No | Item | Designation | Description |
| Productname | CDE6 | Clamprailtemperatureandhumiditycontroller | |
| Function code | 1 | 1groupoutput | |
| ③ | Outputcontact | 10 | Outputcontact10A |
| Ratedoperatingvoltage | M | AC85-240V50/60Hz | |
| Designsequencenumber | A-Z letter combination | Custom voltage |
Commonmodel
| Product Model | Function: | Outputcontactparameter | Rated voltage |
| CDE6-110M | Temperature andhumidity control | Output contact10A | AC220V50/60Hz |
Technicalparameters
| Feature | Temperatureandhumiditycontrol |
| Powerterminal 能卑设计 | www.jrcis.com A1-A2 |
| Ratedoperatingvoltage | 0577-62733721 AC85-240V50/60Hz |
| Power consumption | |
| Powerindicatorlight | GreenLED |
| Relay status light | Red LED |
CDE6 Temperature and Humidity Controller
Technicalparameters
| 设计 | ||
| 技人品 | ||
| Precisionerror | Temperature | ±2°℃ |
| Humidness | ±3%(20%-80%range),±7%(80%) | |
| Outputcontactparameters | 1setoutput,10A250VAC/24VDC | |
| Operatingambienttemperature | -20°℃-+55°℃ | |
| Storageand ransporation ambient | -35°℃~+75℃ | |
| Installation mode | 35mmcardrail installation | |
| Installationelevation | ≤2000m | |
| Pollution level | 2 | |
| Wiringcapacity | 1x2.5mm²or2x1.5mm²0.4N·m | |
| Overalldimension | 90mm×18mm×50mm | |
| Weight | 65g | |
Working mode
HT:RH>RHset or Tamb> Tset,therelaydrawswhen the humidityisgreater than the sethumidityortemperatureis greaterthanthe set temperature.
TH:RH>RHsetor Tamb<
Tset.therelaydrawswhen the humidity isgreater than the sethumidityor the
temperature islessthanthe settemperature.
www.jrcis.com 0577-62733721
HLRH<RHset,therelay drawswhen the humidity is less than the set humidity.
HM:RH>RHset.the relay drawswhenthehumidityis greater than thesethumidity.
Wiring diagram
Shape and size(mm)
Theinstaltonsiuseladandelatethturtavidafngacraf temperatureand humiditydetection.
(Other general notes are copied)
CDV6 Single-Phase Voltage Monitoring Relay
CEAUS
Application
Usedforovervoltageprotectionofelectricalequipmentor compressors. Switching control of emergency/backup power supp
Features
Monitorits own operating voltage (true RMS measurement) Theworkingmodecanbeselectedthroughtheknob. Thevoltage measurement accuracy is <=1% Theworkingstatusof therelay isindicatedbyanLEDindicator. Ultra-small size,only 18mm width, 35mm card rail installation.
Product selection
| No | Item | Code | Description | ||
| Productname | CDV6 | Voltagemonitoringrelay | |||
| ② | Fonction code | 1 | Overvoltage/undervoltageisselectedbyknob | ||
| 2 | It alsohasover and undervoltage function | ||||
| Output contact | 10 | Output contact10A | |||
| 16 | Output contact16A | ||||
| ④ 技 | Rated operating voltage | Codename | Rated supplyvoltage | Limit operating voltage | Set voltage range |
| D12 | DC12V | DC7.20V | DC9.15V | ||
| AD48 rcis.com | AC/DC24..48V | AC/DC15...270V | AC/DC20...80V | ||
| AD240 | AC/DC110..240V | AC/DC50...270V | AC/DC65..260V | ||
| A220 | AC220V | AC160...270V | AC180...260V | ||
CDV6 Single-Phase Voltage Monitoring Relay
| Technical parameters | |||||
| CDV6-01 | CDV6-02 | ||||
| 0577-627337 FunctionT | Voltagemonitoring | 技人 | |||
| Powerterminal(monitoringterminal) | A1(+)-A2(-) | ||||
| Rated supplyvoltage | DC12V,AC/DC24V-48V,AC/DC110V-240V,AC22V | ||||
| Rated power frequency | 45Hz-65Hz,0 | ||||
| Rated insulation vltage | 460V | ||||
| Hysteresis value | 5%-20% | 3% fixed | |||
| Power indicator | Green LED | ||||
| Action delay time | 0.1s-10s,10% | ||||
| Voltagemeasurementerror | ≤1% | ||||
| Power-on delay time | 0.5s | ||||
| Knob setting accuracy | 10% | ||||
| Reset time | 1s 0577-62733721 | ||||
| Temperaturefluctuation error | 0.05%℃at20c牌设计 | ||||
| Output contact parameters | 10A | 1*10A250VAC/24VDC | 2*10A250VAC/24VDC | ||
| 16A | 1*16A250VAC/24VDC | 2*16A250VAC/24VDC | |||
| Minimum switchingpower | 500mW | ||||
| Outputrelayindication | Red LED | ||||
| Mechanical life | 1×10 | ||||
| Electricallife(resistiveload) | 1×10 | ||||
| Operating ambienttemperature | -20°℃~+55°℃ | ||||
| Seand ranporaton mbent | -35°℃-+75℃ | ||||
| Instaltionmethod | 35mmcardrailinstallation | ||||
| Protection level | IP20 | ||||
| Installation location | Arbitrary | ||||
| Installation altitude | ≤2000m | ||||
| Pollution level 品牌设计 | www.jrcis.com 2 | ||||
| Wiring ability | 1x2.5mm²or2x1.5mm²0.8N·m | ||||
| Dimensions | 90mmx18mm×65mm | ||||
| Weight | 67g | ||||
Functiondiagramw
Wiring diagram
Panel diagram
Shape and size (mm)
CDV6 Three-PhaseVoltage Monitoring Relay
www.jrcis.com 577
Application
Used for equipment protection and control (tower cranes,air conditioners,elevators,agriculturalequipment,refrigerated trucks).
Protect the equipment toprevent accidents caused byreverse operation.
Normal/emergencypowerswitch.
■Preventphasedisconnection of thepower load.
Features
Monitor its own operating voltage (true RMS measurement), 45Hz\~65Hzwidefrequencymeasurement.
8kindsofratedvoltagesare adjustable,suitable forvoltages in variousregionsof theworld.
3-phase3-wire and3-phase4-wire specificationsareoptional.
Thevoltage measurement accuracy is <=1%
Ithas an anti-harmonic model,which is optimized forhigh antiinterference occasions.
Theworking statusof therelay isindicatedby anLEDindicator.
Ultra-small size,only18mm width, 35mm card rail installation.
Product selection
| No | Item | Code | Description | ||||||
| Product name | CDV6 | Voltagemonitoringrelay | |||||||
| ② | Functioncode | Function code | Overvoltage | Undervoltage | Voltageimbalance | Actiondelay | Phase sequence protection | Phase-off protection | |
| 3 | 1 | · | · | ||||||
| 4 | 2%..20% | -20%...2% | 0.1s..10s | · | |||||
| 5 | 2%..20% | -20%.2% | 8% | 0.1s.10s | · | · | |||
| 6 | 2%..20% | -20%.2% | 5%.15% | 2s | · | · | |||
| 7 | 5%.15% | 0.1s..10s | · | ||||||
| 8 | 15% | -15% | 8% | 2s | · | · | |||
| Output contact | 16 | Outputcontact16A | |||||||
| Form 2ei | None | Common type | |||||||
| ix | ww.jrcis.com Anti-harmonic type 6273372 | ||||||||
| # | Rated oerating | Codename | Rated voltage gear | ||||||
| P N | 220-230-240-380-400-415-440-460VAC(P-P) | ||||||||
| 127-132-138-220-230-240-254-265VAC(P-N) | |||||||||
CDV6 Three-Phase Voltage Monitoring Relay
| P | N | ||
| 0577-6273372 Function发 | Monitor L-Lvoltage(3-phase3-wire system) | MonitorL-Nvoltage(3-phase 4-wire system)) | |
| Monitoring terminal | L1-L2-L3 | L1-L2-L3-N | |
| Power supply | L1-L2 | L1-N | |
| Rated operating voltage selection | 220-30-2-30-00 | ||
| Measuring frequencyrange | 45Hz-65Hz | ||
| Measuring range | 176V-552V | 101V-318V | |
| Voltage threshold range | 2%-20% (rated voltage) | ||
| Unbalancedvaluethresholdrange | 5%-15% | ||
| Voltagefixedhysteresisrate | 2% | ||
| Powerindicator | GreenLED | ||
| Action delaytime | 0.1s-10s(Adjustable) | ||
| Voltagemeasurementerror | ≤1% | ||
| Power-on delaytime | 0.5s | ||
| Knob setting accuracy | 技10%品牌设计 | ||
| Resettime | 1s | ||
| Temperaturefluctuationerror | 0.05%/°℃,at=20°℃ | ||
| Output contact parameters | 16A | 2*16A250VAC/24VDC | |
| Minimum switching power | 500mW | ||
| Outputrelayindication | Red LED | ||
| Mechanical life | 1×10 | ||
| Electrical life(resistive load) | 1×105 | ||
| Operatingambient temperature | -20°℃~+55℃ | ||
| Seorpand rapratonient | -35℃~+75°℃ | ||
| Installationmethod | 35mmcardrailinstallation | ||
| Protection level | IP20 | ||
| Installation location | Arbitrary | ||
| Installationaltitude | ≤2000m | ||
| Polutonlv卑设计|6s.com | 2 | ||
| Wiring ability | 12.5mm²or 2x1.5mm²0.8N·m | ||
| 90mmx18mmx65mm | |||
| Dimensions: Weight | 67g | ||
Wiring diagram
Panel diagram
Functiondiagramw
CV ThreePhase Voltage Montoring Relay 2 Sets Of Outputs
④ CEUS
www.ircis.com
Application
Used forequipment protection and control(tower cranes,air conditioners,elevators,agricultural equipment,refrigerated trucks).
Protectthe equipment to prevent accidents causedbyreverse operation.
Normal/emergencypowerswitch.
Preventphasedisconnectionof thepowerload.
Features
Monitor its own operating voltage(true RMSmeasurement), 45Hz\~65Hzwidefrequencymeasurement.
Two setsofoutput contacts areusedforprotection and fault alarm.
8kindsofratedvoltages areadjustable,suitable forvoltagesin variousregionsof theworld.
3-phase3-wireand3-phase4-wirespecificationsareoptional.
Thevoltage measurementaccuracyis <=1%
Anti-harmonic design,optimized forhigh anti-interference occasions.
Theworking statusof therelayisindicated by anLEDindicator.
Ultra-small size,only18mmwidth,35mmcardrail installation.
| No | Item | Code | Description | |||||
| ① | Product name | CDV6 | Voltagemonitoringrelay | |||||
| Function code | Function code | Overvoltage | Undervoltage | Voltageimbalance | Actiondelay | Phase sequence protection | Phase-off protection | |
| 3D | 1 | · | · | |||||
| 4D | 2%..20% | -20%...2% | 0.1s.10s | · | ||||
| 5D | 2%..20% | -20%..2% | 8% | 0.1s.10s | · | |||
| 6D | 2%..20% | -20%..2% | 5%.15% | 2s | · | |||
| 7D | - | 5%.15% | 0.1s..10s | · | ||||
| 8D | 15% | -15% | 8% | 2s | · | · | ||
| Output contact | 08 | Output contact 8A | ||||||
| Form 28 | None ww.jrcis.com | Common type | ||||||
| # | Rate oerting | Codename | Anti-harmonictype 62733721 | |||||
| P | Ratedvoltagegear | |||||||
| N | 220-230-240-380-400-415-440-460VAC(P-P) | |||||||
| 127-132-138-220-230-240-254-265VAC(P-N) | ||||||||
CV6 Three-Phase Voltage Monitoring Relay (2 Sets Of Outputs)
Technicalparameters
| P | N | ||
| 0577-6273372 Function交计 | Monitor L-Lvoltage(3-phase3-wire system) | MonitorL-N voltage(3-phase 4-wire system) | |
| Monitoring terminal | L1-L2-L3 | L1-L2-L3-N | |
| Power supply | L1-L2 | L1-N | |
| Rated operatingvoltage selection | 220-230-240-380-400 -415-440-460(P-P) | 127-132-138-220-230 -240-254-265(P-N) | |
| Measuring frequencyrange | 45Hz-65Hz | ||
| Measuring range | 176V-552V | 101V-318V | |
| Voltage threshold range | 2%-20% (rated voltage) | ||
| Unbalanced value threshold range | 5%-15% | ||
| Voltagefixed hysteresisrate | 2% | ||
| Power indicator | Green LED | ||
| Actiondelaytime | 0.1s-10stAdjustable) | ||
| Voltagemeasurementerror | ≤1% | ||
| Power-ondelay time | 0.5s | ||
| Knob setting accuracy | 技 0577-62733720 10%动牌设计 | ||
| Resettime | 1s | ||
| Temperaturefluctuation error | 0.05%/°℃,at=20°℃ | ||
| pourput contact | 8A | 2*8A250VAC/24VDC | |
| Minimum switchingpower | 500mW | ||
| Output relayindication | Red LED | ||
| Mechanical life | 1×10? | ||
| Electricalife(resistivelad | 1×105 | ||
| Operating ambient temperature | -20°℃~+55℃ | ||
| Storandtransprtatonbent | -35℃-+75°℃ | ||
| Installationmethod | 35mm card rail installation | ||
| Protection level | IP20 | ||
| Instllation lcation | Arbitrary | ||
| Installation altitude | ≤2000m | ||
| Polutonlevel卑设6273.com | 2 | ||
| Wiring ability | 1x2.5mm²or2×1.5mm²0.8N·m | ||
| Dimensions | 90mmx18mmx65mm | ||
| Weight | 67g | ||
Wiring diagram
Panel diagram
Function diagram
Application
Liquidleveldetection
Features
Thefollowing twomodesofoperationcanbeimplementedon one specification: 2-polelevel control 1poleliquidlevelcontrol
Drainageandwatersupplymodecanbeset.
Action delay 0.1s-10s adjustable.
Workingpower supplyvoltageAC/DC85\~240V,isolatedpower supply design.
Relayoperating status isindicatedbyLED indicator.
Ultra-smallsize,only18mmwidth,35mmcardrailmounting.
Model designation
| No | Item | Description | |
| CDL6serieswaterlevelrelay | |||
| ② | Function code | Designation | Function description |
| 1 | 2-pole liquid levelmonitoring | ||
| 2 | 1or 2levelmonitoring | ||
| ③ | Output the number of contact groups | Group1conversion | |
| Output contact | Output contact16A | ||
Technical parameters
| CDL6-1116 | CDL6-2116 | |
| Feature 品卑i设i计|www.jrcis.com | 2-pole liquid levelmonitoring | 1or2levelmonitoring |
| Power terminal | A1-A2 | |
| Rated supply voltage | AC/DC24V-240V(50-60Hz) | |
| Powerconsumption | Max2VA | |
CDL6 Sensitivity Adjustable Level Relay
| Technical parameters | ||
| HAi WWW .com | CDL6-1116 | CDL6-2116 |
| Powersupplyallowedfluctuationrange | -15%;+10% | |
| Electrodedetectionvoltage | Max.AC5V | |
| Electrodecurrent | AC | |
| Response time | Max.400ms | |
| Electrode cable allowable distributed capacitance(Max.) | 800nF(sensitivity max).100nF(sensitivitymin) | |
| Electrode cable length | Up to 100meters | |
| Actiondelaytime | 0.1s-10s (adjustable) | |
| Setting accuracy | 10% | |
| Output contact parameters | 1xSPDT | |
| 10A/AC1 | ||
| 250VAC/24VDC 技人 i+|www.jrcis.com | ||
| Minimum switchingpower | 500mW | 0577-62733721 |
| Outputrelayindication | Red LED | |
| Mechanical life | 1x10 | |
| Electrical life | 1x105 | |
| Operatingambienttemperature | -20°C~+55°℃ | |
| Storageandtransportationambienttemperature | -35°C~+75°C | |
| Installationmode | 35mmcardrailinstallation | |
| Class of protection | IP20 | |
| Installationposition | Arbitraril | |
| Installation elevation | ≤2000m | |
| Pollution level | 2 | |
| Wiring capacity | 1x2.5mm²or2x1.5mm²0.4N·m | |
| Overal dimension片军 0577-62733721 | 90mmx18mmx65mm | |
| Weight | 61g 81g | |
| Meet the standard | GB/T 14048.5,EN60255-1 | |
CDL6 Sensitivity Adjustable Level Relay
Function diagramw
Wiring diagram
CEAUS
Application
Pulserelay,can becontrolled from multiple different positions (unlimitednumber),can replace the3-way switch,wiring is moresimple,economicalandconvenient.
Features
Twovoltagespecifications,AC220VorAC/DC12V-240v. AC220Vspecificationcanbeconnectedwithneonlightswitch. Relayoperating statusisindicatedby LED indicator. Ultra-small size,only18mmwidth35mmcardrailmounting
Model designation
| No | Item | Description |
| CDM6serieselectronicpulserelay | ||
| # | Output thenumberof contact groups | 11:1Group conversion |
| 22:2Groupconversion | ||
| Output contact | 10:Output contact 10A | |
| 16:Outputcontact16A | ||
| Rated power supplyvoltage | W:AC/AC22-240V |
Technicalparameters
| CDM6-1 | CDM6-2 | |
| Functionalmodel片卑设i十|www.jrcis.com | 1 | 2 |
| Power terminal | A1-A2 | |
| Ratedsupplyvoltage | AC/DC12V-240V(50-60Hz) | |
| Powerconsumption | AC0.09-3VA/DC0.05-1.2W | |
Technicalparameters
| CDM6-1 | CDM6-2 技人 | |||
| HR m | AC230V(50-60Hz) | |||
| Power consumption | ACmax.12VA/1.3W | |||
| Power supplyallowed fluctuationrange | -15%;+10% | |||
| Power indicator light | GreenLED | |||
| Control terminal | A1-S | |||
| Neon connection | AC230Vspecificationsavailable(A1-S) | |||
| Maximumnumberofneonconnections | 230V,upto75PCS(about0.68mA/230VACat neon current) | |||
| Control signalwidth | Min.25ms | |||
| Outputrelay | 1XSPDT | |||
| 16A/AC1 | ||||
| 250VAC/24VDC | ||||
| Minimumswitchingpower | 500mW | |||
| Outputrelayindication | RedLED | |||
| Mechanicallife | 1x10 | |||
| Electrical life | 技人邑 设计1wrais.com | |||
| Resettime | Max.200ms | |||
| Operating ambienttemperature | -20°C~+55°C | |||
| Storageand transportation ambient temperature | -35°C-+75°C | |||
| Installationmode | 35mm cardrail installation | |||
| Class of protection | IP20 | |||
| Installationposition | Arbitrarily | |||
| Installationelevation | ≤2000m | |||
| Pollutionlevel | 2 | |||
| Wiringcapacity | 1x2.5mm²or2x1.5mm²0.4N·m | |||
| Overalldimension | 90mm×18mmx65mm | |||
| Weight | ||||
| Meetthe standard | W240-58g.A220-57g GB/T14048.5,EN60810-1 | |||
Function diagramw
Wiring diagram
Panel diagram
Theligtatldtienronddifentfadndinttu
Shape and size (mm)
CDW6 Temperature Control Relay
Application
Used forheater temperature control,equipment,room temperaturecontrol,cabinetequipmentriskcontrol system.
Features
Using NTC sensor,with sensor short circuit,open circuit monitoring.
Optionalheating/coolingoperationmode.
Workingpower supplyvoltageAC/DC24Vto240v.
TheworkingstatusisindicatedbyLEDindicator.
UItra-small size,only18mmwidth,35mmcardrailmounting.
Model designation
| No | Item | Description | |
| CDW6seriestemperaturecontrolrelay | |||
| ② | Design sequencenumber | Designation | Operating voltage |
| 1 | High/low temperaturemonitoring | ||
| 2 | Temperaturerangemonitoring | ||
| Output thenumber of contactgroups | 1 | 1groups | |
| Output contact | 16 | Output contact16 | |
Technicalparameters
| CDW6-1 | CDW6-2 | |
| Functional model | Monitorhigh/lowtemperatures | Monitoring temperaturerange |
| Powerterminal | L-N | |
| Rated supply voltage卑设计 0577-62733721 | AC/DC24V-240V | |
| Rated power frequency | 50/60Hz | |
| Powerconsumption | Max.2VA | |
| Powersupplyallowedfluctuationrange | -15%:+10% | |
Dual Mode Temperature Control Relay
Technicalparameters
| CDW6-1 | CDW6-2 | |
| Temperaturecontrolrange7-62733721 | -15Cto+45C | |
| Temperaturemeasurementerror | ±2℃ | |
| Temperatureadjustment lagvalue | 0.5°℃to5°℃ | |
| Workingmode | Heating-cooling-on-off can be set | |
| Powerindicatorlight | GreenLED | |
| Outputcontactparameters | 1xSPST | |
| 16A/AC1 | ||
| 250VAC/24VDC | ||
| Minimum switchingpower | 500mW | |
| Outputrelayindication | Red LED | |
| Mechanical life | 1x102 | |
| Electrical life | 1x105 | |
| Operating ambient temperature | -20°℃-+55°℃ | |
| Storageand transportationambient temperature | -35℃-+75℃ www.jrcis.com 凸计 | |
| Installationmode | 35mmcardrail installation | |
| Class of protection | IP20 | |
| Installation position | Arbitrarily | |
| Installation elevation | 2000m | |
| Pollution level | 2 | |
| Wiring capacity | 1x2.5mm²or2x1.5mm²0.8N-m | |
| Overalldimension | 90mm×18mmx65mm | |
| Weight | 62g | |
| Meet the standard | GB/T14048.5,EN60255-1 | |
Function diagramw
Shape and size (mm)
Wiringdiagram
Application case diagram
Panel diagram
CDR6 ModularIntermediateRelay
CEAUS
Application
Intermediaterelaysareused toswitchacertaincurrentload, increasetheloadcapacityorincreasethenumberof contact groups. L
Features
Ratedvoltage:AC/DC12V,24V,48V,110V,AC220V.
CDR6-316canbeused to switch three-phasecircuits.
Relayoperating statusisindicatedbyLEDindicator.
Ultra-small size,only18mmwidth35mmcardrailmounting.
Model designation
| No | Item | Description | |
| CDR6seriesintermediaterelay | |||
| Output thenumberof contact groups | Designation | Operating voltage | |
| 1116 | 1xSPDT16A | ||
| 2216 | 2xSPDT16A | ||
| 1110 | 1xSPDT10A | ||
| 2210 | 2xSPDT10A | ||
| 人品unction cd62i7 0577-627337 | Designation | Operatingvoltage | |
| 12 | AC/DC12V | ||
| com 24 | AC/DC24V | ||
| 48 | AC/DC48V | ||
| 110 M | AC/DC110V AC220V | ||
CDR6 ModularIntermediateRelay
Technicalparameters
| CDR6-1116 | CDR6-2216 | CDR6-1110 | CDR6-2210 | |
| Power terminal 0577-62733721 | A1-A2 | 技人 | ||
| Rated supplyvoltage | AC/DC12V,24V,48V,1V | |||
| Power consumption | AC.max12VA/DC.max1.9W | |||
| Power terminal | A1-A2-A3 | |||
| Rated supplyvoltage | AC220V(A1-A2),AC/DC24V(A1-A3) | |||
| Powerconsumption | AC.max12VA/DC.max1.9W | |||
| Power supplyallowed fluctuationrange | -15%;+10% | |||
| Maximum switching time | 40ms | |||
| Output contactparameters | 1xSPDT | 2xSPDT 1XSPDT | 2XSPDT | |
| 1x16A | 2×16A | 1X10A | 2×10A | |
| 250VAC/24VDC | ||||
| Minimumswitchingpower | 500mW | |||
| Outputrelayindication | Red LED | |||
| Mechanical life | 1x102 | |||
| Electricallife | 1x105 | |||
| Reset time | max.200ms | |||
| Operating ambient temperature | -20°℃+55℃C-49Fto 131-F)j|WWW.jrcis.c0m | |||
| Storageandtransportationambienttemperature | -35°C-+75°C(-22°Fto158°F) | |||
| Installationmode | 35mmcardrail installation | |||
| Class of protection | IP20 | |||
| Installation position | Arbitrarily | |||
| Overvoltage class | ||||
| Pollution level | 2 | |||
| Wiringcapacity | 1x2.5mm²or2x1.5mm²0.8N-m | |||
| Overalldimension | 90mm×18mmx65mm | |||
| Weight | ||||
| 67g | 80g | 55g | 70g | |
Wiring diagram
Shape and size(mm)
Sensor Division
CJY Proximity Sensor Cylindrical Type E01-09
CJY-TProximity Sensor Cylindrical Connector Type E10-16
CJY-R Proximity Sensor Cylindrical Cable Connector Type E17-23
CJY S Long Distance Proximity Sensor Cylindrical Type E24-27
CJY s-T LongDistance Proximity Sensor Cylindrical Connector Type E28-31
CJYs-R Long DistanceProximity Sensor Cylindrical Cable Connector Type E32-35
CJFProximity Sensor Square Type E36-42
技人品牌设计
CJF Proximity Sensor Flat Type E43-45
CJFProximity Sensor Cylindrical Type E46-50
CJF Long DistanceProximity Sensor Flat Type E51-53
CRY Capacitive Proximity Sensor E54-56
CMY Analog Proximity Sensor E57-58
CHY Hall Sensor E59-60
CXY Magnetic Sensor E61-62
CGY Photoelectric Sensor Cylindrical Type E63-68
CGF Photoelectric Sensor Square Type E69-78
CGU Photoelectric Sensor U Type E79-82
Sensor Accessories E83
CJ Proximity Sensor Cyindrical Type
CCES
Features
Orangemarkforstandardtype Lightgreenmarkforhigh-end type
Insidesurgeprotection,reversepolarityprotection
Longuse-lifecycleandhighreliability,easyinstallenconomicprice
RedLEDstatusindication,easytoconfirmworksituation
ProtectionstructureIP67(IECstandard)
Replaceableforlimitswitches
ExclusivelydesignedICforimprovinganti-jammingcapability
Model Number Structure
| Item | Code | Description |
| ①Companycode | C | Companycode |
| ②Product name | J | Inductiveproximitysensor |
| ③Shape of shell | Y | Cylinder-shaped |
| ④Dimensioncode | 18 | 18=M18 |
| Product type | Without | Without=High-endtype(Light green head) |
| E | E=Standard type(Orange head) | |
| Detection distance | 08 | 08=8mm |
| Output mode | K | AC2wires |
| L | DC2wires | |
| P N | PNP3wires | |
| ⑧Output state www.jrcis 牌设计 | A | NPN3wires |
| B | NO | |
| 0577-627337 | com C | NC |
| NO+NC | ||
| Connection | Without | Without:Leadwire |
| T | Plug-in | |
| R | Wiring leadsPlug-in |
CJY Proximity Sensor Cylindrical Type
Specifications
DC3-wire type
| 牌 Model | 计 High-end type | CJY04-01NA 27337CJY04-01NA CJY04-01PB | CJY05-01NA C.JY05-01NBA CJY05-01PB | CJY06-01NA CJY06-01BA CJY06-01PB | CJY6.5-1.5NA CJY6 5-15SBA CJY6.5-1.5PB |
| Standard type | / | 1mm | 1.5mm | ||
| Sensing distance | 1mm 1mm | ||||
| Hysteresis | Max.10%ofsensingdistance | ||||
| Standardsensing target | 6×6×1mm 0~0.8mm | 7×7×1m 0~0.8mm | 8×8 1m 0~1.0mm | 8×8×1.5m 0~6.5mm | |
| Setting distance | |||||
| (opersugvyotage) | 12-24VDC(10-30VDC) | ||||
| Leakage current | Max.10mA 1500Hz | 1000Hz | 1000Hz | ||
| Response frequency(*1) | 1500Hz | ||||
| Residual voltage(2) | Max.1.0V | ||||
| Affectionby Temp. | Max.±10%forsensingdistanceatambienttemperature20C | ||||
| Control output | Max.200mA | ||||
| Insulationresistance | 牌设计10577-62733720 Min.50MQ(at500VDCmegger) | ||||
| Dielectricstrength | 1500VAC50/60Hzfor1minute | ||||
| Vibration | 1mmamplitudeatfrequencyof10to55Hz(for1min.)ineachofX,Zdirectionsfor2hours | ||||
| Shock | 500m/s(approx.50G)X,Y,Zdirectionsfor3times Operationindicator(redLED) | ||||
| Indicator | -25~+70C(No icing) | ||||
| Ambient temperature | -30~+80C(No icing) | ||||
| Storage temperature | 35~95%RH(No condensation) | ||||
| Ambient humidity | Surgeprotectincircuiteversepolarityrotectioncircuitvercurrentprotctioniruit | ||||
| Protectioncircuit Material | CaseNt: lraiy | ||||
| Cable | 2.8,3P,2m | ||||
| AWG22,Corediameter:0.1mm,Numberofcores:22,Insulatordiameter:1.25 | |||||
| Protection | IP67 | ||||
| Specifications DC3-wire type | ||||||||||
| 牌设计 Model | High-end type | CJY08-01NA C.JY08-01NBA CJY08-01PB | CJY08-02NA CJY08-2BA CJY08-02PB | CJY12-02NB CJY12-02NCCJY1204NA CJY12-02PB CJY12-02PCCJY12-04PC | CJY12-04NB CJY12-04PB | CJY18-05NB CJY18-05PB | CJY12-02NA|CJY12-04NA|CJY18-05NA|CJY18-08NA|CJY30-10NACJY30-15NA CJY18-08NB CJY1805NACJY18-0NACJY30-10NC CJY18-08PB CJY18-05PCCJY18-08PCCJY30-10PCCJY30-15PC | CJY30-10NB CJY30-10PB | CJY30-15NB CJY30-15NC CJY30-15PB | |
| Standard type | CJY08E-01NA|CJY08E-02NACJY12E-02NBCJY12E-04NB CJYOBE-1ACJIYO8E-2ACJY12E02NCCJY12E-04NC CJY08E-01PBCJY08E-02PB | CJY18E-05NBCJY18E-08NB | CJY12E-02NACJY12E-04NACJY18E-05NA|CJY18E-08NACJY30E-10NA CJY30E-15NA CJY30E-10NBCJY30E-15NB 185N1J30E101 | |||||||
| Sensing distance | 1mm | 2mm | CJY12E-02PB CJY12E-02PCCJY12E-04PC 2mm | CJY12E-04PB 4mm | 5mm | CJY18E-05PBCJY18E-08PB 8mm | CJY18E-05PCCJY18E-08PCCJY30E-10PCCJY30E-15PC | CJY30E-10PBCJY30E-15PB 15mm | ||
| Hysteresis | Max.10%of sensing distance | 10mm | ||||||||
| Standardsensing target | 8× 8×1mm | 12 × 12×1mm | 25 x251m | 30× 301mm | 45 ×45×1m | |||||
| Setting distance | 0~0.8mm 0~1.4mm | 0~1.4mm 0~2.8mm | 18 181m 0~3.5mm | 0~5.6mm | 0~7mm | 0~10.5mm | ||||
| Power supply (Operating voltage) | 12-24VDC(10-30VDC) | |||||||||
| Leakage current | ||||||||||
| Response frequency(*1)) | 1000Hz | 1000Hz | 1000Hz | Max.10mA 500Hz | 350Hz | 200Hz | ||||
| Residual voltage | ||||||||||
| Affectionby Temp. | Max.1.0V | |||||||||
| Max.±10%forsensing distanceatambient temperature20℃ | ||||||||||
| 设11 1 65425372 | ||||||||||
| Dielectric strength | ||||||||||
| Vibration | 1500VAC50/60Hzfor1minute | |||||||||
| 1mmamplitudeatfrequencyof10to55Hz(for1min.)ineachofX,Zdirectionsfor2hours | ||||||||||
| Shock Indicator | 500m/s²(approx.50G)X,Y,Z directions for 3 times Operationindicator(redLED) | |||||||||
| Ambienttemperature | -25~+70C (No icing) | |||||||||
| Storagetemperature | -30~+80C(No icing) | |||||||||
| Ambienthumidity | 35~95%RH(No condensation) | |||||||||
| Protectioncircuit | Surgeprotectioncircuiteversepolarityrotectioncircuitvercurrentprotectioncicuit | |||||||||
| Material High-end | 2.8,3P,2m | 3.8,3P,4P2m | CaN 中4.8,3P,4P2m | |||||||
| 0.12edaet Insulatordiameter:1.25) | 0.1A2re da | (AWG22 | ||||||||
| Standard type | 2.8,3P,1.5m | Insulator diameter:1.25) 3.8,3P,4P1.5m | Φ4.8,3P,4P 1.5m | |||||||
| (AWG22,Corediameter: 0.1mm,Number of cores:22, 品 Insulatordiameter:1.25) | (AWG22,Corediameter: 0.1mm,Numberof cores25 Insulatordiameter:1.25) | (AWG22,Corediameter:0.1mm,Numberofcores:30, Insulator diameter:Φ1.25) | ||||||||