www.unionele.com
union@unionele.com chinaelectrical@hotmail.com
th
9 Floor A Buliding Baitawang Complex Dongda Street North Baixiang Town Yueqing, Zhejiang, China.
[ T ] + 86 (577) 6286 7999
UNION ELECTRICS
Toroidal Current Transformer
Earth Leakage Relay
Modular Contactors Analog Timer
Thermal Relay
Motor Protection Switches
54/55
56/57
50/51 66
58/60
65
61/62 Automatic transfer switch
63/64 Manual Changeover Switch
AC Contactor
01/05 Air Circuit Breaker
06/09
10/11
17/37
38/49
52/53
12 MCB Isolator
13/16
Molded Case Circuit Breaker
Miniature Circuit Breaker
Residual Current Circuit Breaker
Residual Current Circuit Breaker
With Overcurrent Protection
Surge Protector Device
Table
Of
Contents
Toroidal Current Transformer
Earth Leakage Relay
Modular Contactors Analog Timer
Thermal Relay
Motor Protection Switches
54/55
56/57
50/51 66
58/60
65
61/62 Automatic transfer switch
63/64 Manual Changeover Switch
AC Contactor
01/05 Air Circuit Breaker
06/09
10/11
17/37
38/49
52/53
12 MCB Isolator
13/16
Molded Case Circuit Breaker
Miniature Circuit Breaker
Residual Current Circuit Breaker
Residual Current Circuit Breaker
With Overcurrent Protection
Surge Protector Device
Table
Of
Contents
B Curve (3-5ln)
Designed for cable protection. Suitable for resistive loads such as electrical heating, water heater and stoves, and long cable runs (fault
loop impedance)
C Curve (5-10ln)
Designed for medium magnetic startups. Suitable for common loads such as lighting, socket outlets, small motors.
D Curve(10-14ln)
Designed to allow for high inrush loads. Suitable for high inrush loads such as motors, welding and spot machines, halogen, sodium
vapour lamps and transformers.
Tripping Curves
Trip Characteristic Curve
10000
5000
1h
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001 0.5 1 2 3 4 5 7 1014 20 30 50 70 100 200 I/In
t(s)
IEC/EN 60898-1 AC type D curve
10000
5000
1h
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001 0.5 1 2 34 5 7 10 20 30 50 70 100 200 I/In
t(s) IEC/EN 60898-1 AC type B curve IEC/EN 60898-1 AC type C curve t(s)
10000
5000
1h
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
Structure
High torque terminal for
Line /load power
Bi-metallic strip
Quick make actuator mechanism
Contact
Electromagnetic system
Efficient arc extinguisher
Handle
Adjusting screw
Connection pin
Din rail clip
The high quality non-flammable
960 C polyamide 6 material
1~63
1~63
1
2、3、4
230/400
400
6000
10000 7500
Model number Rated current(A) Number of poles Rated voltage(V) Rated short
circuit current(A)
Operating
short-circuit
current(A)
1
2、3、4
230/400
400
6000
www.unionele.com I 02
UNION ELECTRICS
Miniature Circuit Breaker
HIG-10D,HIG-10DC
MED-6D,HIG-6DC
Function
General
Selection
Miniature
Circuit
Breaker
Technical Data
No.of poles
Rated nominal current (at 30°C)
Instantaneous tripping class
Rated operating voltage
Power supply
Rated insulation voltage
Rated impulse withstanding voltage
Rated short circuit breaking capacity
Energy limiting class
Electrical life (operation)
Mechanical life (operation)
Protection class
Operating temperature
Storage temperature
Colour
Assembly (EN 60715)
Min. Max. Connection section
Max. Clamping torque
Type
In
Ue
Ui
Uimp
Ics
op.
op.
AC (V)
V
kV
KA
230 V
℃
℃
mm²
Nm
1 2 3 4
2, 4, 6, 10, 16,20,
25,32, 40, 50, 63
B:(3-5)xln
C:(5-10)xIn
D:(10-20)xIn
230/400 400
AC
690
6
4,5
3
4000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
1-25
2,5
1 2 3 4
2, 4, 6, 10, 16,20,
25,32, 40, 50, 63
B:(3-5)xln
C:(5-10)xIn
D:(10-20)xIn
1 2 3 4
2, 4, 6, 10, 16,20,
25,32, 40, 50, 63
B:(3-5)xln
C:(5-10)xIn
D:(10-20)xIn
80, 100, 125 6, 10, 16,20,
25,32, 40, 50, 63
C:(7-14)xIn
ECO-4.5D MED-6D HIG-10D HIG-6DC
A
01 I www.unionele.com
ECO-4.5D,MED-6D,HIG-10D,HIG-10DL,HIG-6DC and HIG-10DC types provide protection of circuits against short-circuit currents,
protection against overload currents, switching and isolation. These circuit-breakers are used in domestic installations as well as in
commercial and industrial electrical distribution systems.
When selecting the circuit-breaker, the technical data of the electrical installation at the installation point must be considered. The
prospective short-circuit current at this point must always be lower than the breaking capacity of the device, and the rated voltage of
the installation must comply with the device specifications.
1 2 4
6, 10, 16,20,
25,32, 40, 50, 63
C:(7-14)xIn
HIG-10DL HIG-10DC
230/400 400
AC
690
6
6
3
5000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
1-25
2,5
230/400 400
AC
690
6
10
3
6000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
1-25
2,5
AC
690
6
10
3
5000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
25-50
3,5
DC
440
6
6
3
3000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
1-25
2,5
48 110 250
DC
440
6
10
3
3000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
1-25
2,5
1 2 4
250 500 1000
1 2 3 4
230/400 400
UNION ELECTRICS
Miniature Circuit Breaker
B:(3-5)xln
C:(5-10)xIn
D:(10-20)xIn
B Curve (3-5ln)
Designed for cable protection. Suitable for resistive loads such as electrical heating, water heater and stoves, and long cable runs (fault
loop impedance)
C Curve (5-10ln)
Designed for medium magnetic startups. Suitable for common loads such as lighting, socket outlets, small motors.
D Curve(10-14ln)
Designed to allow for high inrush loads. Suitable for high inrush loads such as motors, welding and spot machines, halogen, sodium
vapour lamps and transformers.
Tripping Curves
Trip Characteristic Curve
10000
5000
1h
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001 0.5 1 2 3 4 5 7 1014 20 30 50 70 100 200 I/In
t(s) IEC/EN 60898-1 AC type D curve
10000
5000
1h
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001 0.5 1 2 34 5 7 10 20 30 50 70 100 200 I/In
t(s) IEC/EN 60898-1 AC type B curve IEC/EN 60898-1 AC type C curve t(s)
10000
5000
1h
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001 0.5 1 2 3 4 5 7 10 20 30 50 70 100 200 I/In
Structure
High torque terminal for
Line /load power
Bi-metallic strip
Quick make actuator mechanism
Contact
Electromagnetic system
Efficient arc extinguisher
Handle
Adjusting screw
Connection pin
Din rail clip
The high quality non-flammable
960 C polyamide 6 material
1~63
1~63
1
2、3、4
230/400
400
6000
10000 7500
Model number Rated current(A) Number of poles Rated voltage(V) Rated short
circuit current(A)
Operating
short-circuit
current(A)
1
2、3、4
230/400
400
6000
www.unionele.com I 02
UNION ELECTRICS
Miniature Circuit Breaker
HIG-10D,HIG-10DC
MED-6D,HIG-6DC
Function
General
Selection
Miniature
Circuit
Breaker
Technical Data
No.of poles
Rated nominal current (at 30°C)
Instantaneous tripping class
Rated operating voltage
Power supply
Rated insulation voltage
Rated impulse withstanding voltage
Rated short circuit breaking capacity
Energy limiting class
Electrical life (operation)
Mechanical life (operation)
Protection class
Operating temperature
Storage temperature
Colour
Assembly (EN 60715)
Min. Max. Connection section
Max. Clamping torque
Type
In
Ue
Ui
Uimp
Ics
op.
op.
AC (V)
V
kV
KA
230 V
℃
℃
mm²
Nm
1 2 3 4
2, 4, 6, 10, 16,20,
25,32, 40, 50, 63
B:(3-5)xln
C:(5-10)xIn
D:(10-20)xIn
230/400 400
AC
690
6
4,5
3
4000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
1-25
2,5
1 2 3 4
2, 4, 6, 10, 16,20,
25,32, 40, 50, 63
B:(3-5)xln
C:(5-10)xIn
D:(10-20)xIn
1 2 3 4
2, 4, 6, 10, 16,20,
25,32, 40, 50, 63
B:(3-5)xln
C:(5-10)xIn
D:(10-20)xIn
80, 100, 125
6, 10, 16,20,
25,32, 40, 50, 63
C:(7-14)xIn
ECO-4.5D MED-6D HIG-10D HIG-6DC
A
01 I www.unionele.com
ECO-4.5D,MED-6D,HIG-10D,HIG-10DL,HIG-6DC and HIG-10DC types provide protection of circuits against short-circuit currents,
protection against overload currents, switching and isolation. These circuit-breakers are used in domestic installations as well as in
commercial and industrial electrical distribution systems.
When selecting the circuit-breaker, the technical data of the electrical installation at the installation point must be considered. The
prospective short-circuit current at this point must always be lower than the breaking capacity of the device, and the rated voltage of
the installation must comply with the device specifications.
1 2 4
6, 10, 16,20,
25,32, 40, 50, 63
C:(7-14)xIn
HIG-10DL HIG-10DC
230/400 400
AC
690
6
6
3
5000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
1-25
2,5
230/400 400
AC
690
6
10
3
6000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
1-25
2,5
AC
690
6
10
3
5000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
25-50
3,5
DC
440
6
6
3
3000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
1-25
2,5
48 110 250
DC
440
6
10
3
3000
20000
IP 20
-30 to +60
-40 to +70
RAL 7035
35 mm. DlN Rail
1-25
2,5
1 2 4
250 500 1000
1 2 3 4
230/400 400
UNION ELECTRICS
Miniature Circuit Breaker
B:(3-5)xln
C:(5-10)xIn
D:(10-20)xIn
High short-circuit breaking capacity.
Dual wiring function: the outlet end can be easily connected to standard busbars, as well as soft and hard wires.
Red and green safety indication for higher safety.
With energy-storage mechanism operation, the contact closes quickly, reducing adverse influence from manual handle operation and
significantly improving service life.
Terminals equipped with dovetails to prevent misconnection, improving wiring efficiency and reliability.
Compatible with a variety of modular accessories.
Housing and other plastic parts are made of high flame-retardant, high-temperature and impact-resistant materials.
Overall And Mounting Dimensions (mm)
77.5mm
49mm
35.5mm 45mm
H
17.8mm 35.6mm 53.4mm 71.2mm
*HIG-10DL: Height(H)=85.5mm
ECO-4.5D, HED-6D, HIG-10D, HIG-6DC, HIG-10DC : Height(H)=81.5mm
The reference temperature is 30℃
1
2
3
4
6
10
16
20
25
32
40
50
63
1.30
2.60
3.90
5.20
7.80
13.20
21.12
26.40
33.00
42.56
53.20
67.00
83.79
1.26
2.52
3.78
5.04
7.56
12.70
20.48
25.60
32.00
41.28
51.20
65.50
81.90
1.23
2.46
3.69
4.92
7.38
12.50
20.00
25.00
31.25
40.00
50.00
63.00
80.01
1.19
2.38
3.57
4.76
7.14
12.00
19.20
24.00
30.00
38.72
48.00
60.50
76.86
1.15
2.28
3.42
4.56
6.84
11.50
18.40
23.00
28.75
37.12
46.40
58.00
73.71
1.11
2.20
3.30
4.40
6.60
11.10
17.76
22.20
27.75
35.52
44.80
56.00
70.56
1.05
2.08
3.12
4.16
6.24
10.60
16.96
21.20
26.50
33.92
42.40
53.00
66.78
0.96
1.92
2.88
3.84
5.76
9.60
15.36
19.20
24.00
30.72
38.40
48.00
60.48
0.93
1.86
2.79
3.76
5.64
9.30
14.88
18.60
23.25
29.76
37.20
46.50
58.90
0.88
1.76
2.64
3.52
5.28
8.90
14.24
17.80
22.25
28.16
35.60
44.00
55.44
0.83
1.66
2.49
3.32
4.98
8.40
13.44
16.8
21.00
26.88
33.6
41.50
52.29
Rated current(A)
Ambient temperature
-35℃ -30℃ -20℃ -10℃ 0℃ 10℃ 20℃ 40℃ 50℃ 60℃ 70℃
1.00
2.00
3.00
4.00
6.00
10.00
16.00
20.00
25.00
32.00
40.00
50.00
63.00
30℃
Because of their quick make-and-break design and excellent arc-quenching capability, Union miniature circuit breakers are suitable for
DC applications. For MCBs designed for AC use but applied in DC installations, the following considerations must be observed:
For overload protection, both poles of the MCB must be connected. Under these conditions, the tripping characteristic of the MCB in
DC is similar to that in AC.
For short-circuit protection, both poles of the MCB must be connected. Under these conditions, the tripping characteristic of the MCB
in DC is approximately 40% higher than in AC.
Operation in DC Current
www.unionele.com I 04
Structural Characteristics
UNION ELECTRICS
Miniature Circuit Breaker
Temperature Derating
Wiring: It is suitable for copper wire connection below 25mm , The 2
wiring method is to tighten the wiring with screws and the torque
is 2.0N·8m
Rated current In(A) Nominal cross-sectional area
2
of copper conductor(mm )
1~6
10
16、20
25
32
40、50
63
1
1.5
2.5
4
6
10
16
Rated current range In(A) Maximum power
consumption per pole (W)
In ≤10
10<In ≤16
16<In ≤25
25<In ≤32
32<In ≤40
40<In ≤50
50<In ≤63
2.5
3
4
5
6
8
10
Power consumption per pole of the circuit breaker
Current Correction Factor Used At Different Altitudes
Trip type Rated current (A) Current correction factor Give an example
≤ 2000m (2000~3000)m ≥ 3000m
B、C、D
1、2、3、4、6、
10、16、20、25、
32、40、50、63、
80、100、125
1 0.9 0.8
Rated current 10A The rated
current of the product after
2500m capacity reduction is:
0.9×10=9A
Mechanical Electrical life
Electrical life
Mechanical life
Category Number (times) Operating frequency
(times/hour) Rated current (A)
10000
20000
240
120
1~32
40~63
240 1~63
Magnetic Tripping Condition
Magnetic Tripping
Characteristic Test Current TrippingTime Result
B
B
C
C
D
D
3 In
5 In
5 In
10 In
10 In
20 In
t≥0.1 sec
t<0.1 sec
t≥0.1 sec
t<0.1 set
≥0.1 sec
t<0.1 sec
Not tripped
Tripped
Not tripped
Tripped
Not tripped
Tripped
Thermal Tripping Condition
Rated Current(In) Test Current TrippingTime Result
In ≤ 63 A
In >63 A
In ≤ 63 A
In>63 A
In ≤ 32 A
In>32 A
1.13 ln
1.13 In
1.45 In
1.45 In
2.55 ln
2.55 ln
t>1 hour
t≥ 2 hour
t< 1 hour
t<2 hour
1 sec<t< 60 sec
1 sec<t<120 sec
Not tripped
Not tripped
Tripped
Tripped
Tripped
Tripped
03 I www.unionele.com
MCB are designed and calibrated to carry their rated current and to operate within their specified thermal time/current zone at 30 °C.
Testing is carried out with the breaker mounted individually in a vertical position under controlled conditions.
If the circuit breaker is required to operate in environments that differ from these reference conditions, correction factors must be
applied to the standard data. For example, when operating at ambient temperatures higher than 30 °C, the breaker will trip at
progressively lower currents within the designated time/current zone.
UNION ELECTRICS
Miniature Circuit Breaker
High short-circuit breaking capacity.
Dual wiring function: the outlet end can be easily connected to standard busbars, as well as soft and hard wires.
Red and green safety indication for higher safety.
With energy-storage mechanism operation, the contact closes quickly, reducing adverse influence from manual handle operation and
significantly improving service life.
Terminals equipped with dovetails to prevent misconnection, improving wiring efficiency and reliability.
Compatible with a variety of modular accessories.
Housing and other plastic parts are made of high flame-retardant, high-temperature and impact-resistant materials.
Overall And Mounting Dimensions (mm)
77.5mm
49mm
35.5mm 45mm
H
17.8mm 35.6mm 53.4mm 71.2mm
*HIG-10DL: Height(H)=85.5mm
ECO-4.5D, HED-6D, HIG-10D, HIG-6DC, HIG-10DC : Height(H)=81.5mm
The reference temperature is 30℃
1
2
3
4
6
10
16
20
25
32
40
50
63
1.30
2.60
3.90
5.20
7.80
13.20
21.12
26.40
33.00
42.56
53.20
67.00
83.79
1.26
2.52
3.78
5.04
7.56
12.70
20.48
25.60
32.00
41.28
51.20
65.50
81.90
1.23
2.46
3.69
4.92
7.38
12.50
20.00
25.00
31.25
40.00
50.00
63.00
80.01
1.19
2.38
3.57
4.76
7.14
12.00
19.20
24.00
30.00
38.72
48.00
60.50
76.86
1.15
2.28
3.42
4.56
6.84
11.50
18.40
23.00
28.75
37.12
46.40
58.00
73.71
1.11
2.20
3.30
4.40
6.60
11.10
17.76
22.20
27.75
35.52
44.80
56.00
70.56
1.05
2.08
3.12
4.16
6.24
10.60
16.96
21.20
26.50
33.92
42.40
53.00
66.78
0.96
1.92
2.88
3.84
5.76
9.60
15.36
19.20
24.00
30.72
38.40
48.00
60.48
0.93
1.86
2.79
3.76
5.64
9.30
14.88
18.60
23.25
29.76
37.20
46.50
58.90
0.88
1.76
2.64
3.52
5.28
8.90
14.24
17.80
22.25
28.16
35.60
44.00
55.44
0.83
1.66
2.49
3.32
4.98
8.40
13.44
16.8
21.00
26.88
33.6
41.50
52.29
Rated current(A)
Ambient temperature
-35℃ -30℃ -20℃ -10℃ 0℃ 10℃ 20℃ 40℃ 50℃ 60℃ 70℃
1.00
2.00
3.00
4.00
6.00
10.00
16.00
20.00
25.00
32.00
40.00
50.00
63.00
30℃
Because of their quick make-and-break design and excellent arc-quenching capability, Union miniature circuit breakers are suitable for
DC applications. For MCBs designed for AC use but applied in DC installations, the following considerations must be observed:
For overload protection, both poles of the MCB must be connected. Under these conditions, the tripping characteristic of the MCB in
DC is similar to that in AC.
For short-circuit protection, both poles of the MCB must be connected. Under these conditions, the tripping characteristic of the MCB
in DC is approximately 40% higher than in AC.
Operation in DC Current
www.unionele.com I 04
Structural Characteristics
UNION ELECTRICS
Miniature Circuit Breaker
Temperature Derating
Wiring: It is suitable for copper wire connection below 25mm , The
2
wiring method is to tighten the wiring with screws and the torque
is 2.0N·8m
Rated current In(A)
Nominal cross-sectional area
2
of copper conductor(mm )
1~6
10
16、20
25
32
40、50
63
1
1.5
2.5
4
6
10
16
Rated current range In(A)
Maximum power
consumption per pole (W)
In ≤10
10<In ≤16
16<In ≤25
25<In ≤32
32<In ≤40
40<In ≤50
50<In ≤63
2.5
3
4
5
6
8
10
Power consumption per pole of the circuit breaker
Current Correction Factor Used At Different Altitudes
Trip type Rated current (A)
Current correction factor
Give an example
≤ 2000m (2000~3000)m ≥ 3000m
B、C、D
1、2、3、4、6、
10、16、20、25、
32、40、50、63、
80、100、125
1 0.9 0.8
Rated current 10A The rated
current of the product after
2500m capacity reduction is:
0.9×10=9A
Mechanical Electrical life
Electrical life
Mechanical life
Category Number (times)
Operating frequency
(times/hour)
Rated current (A)
10000
20000
240
120
1~32
40~63
240 1~63
Magnetic Tripping Condition
Magnetic Tripping
Characteristic
Test Current TrippingTime Result
B
B
C
C
D
D
3 In
5 In
5 In
10 In
10 In
20 In
t≥0.1 sec
t<0.1 sec
t≥0.1 sec
t<0.1 set
≥0.1 sec
t<0.1 sec
Not tripped
Tripped
Not tripped
Tripped
Not tripped
Tripped
Thermal Tripping Condition
Rated Current(In) Test Current TrippingTime Result
In ≤ 63 A
In >63 A
In ≤ 63 A
In>63 A
In ≤ 32 A
In>32 A
1.13 ln
1.13 In
1.45 In
1.45 In
2.55 ln
2.55 ln
t>1 hour
t≥ 2 hour
t< 1 hour
t<2 hour
1 sec<t< 60 sec
1 sec<t<120 sec
Not tripped
Not tripped
Tripped
Tripped
Tripped
Tripped
03 I www.unionele.com
MCB are designed and calibrated to carry their rated current and to operate within their specified thermal time/current zone at 30 °C.
Testing is carried out with the breaker mounted individually in a vertical position under controlled conditions.
If the circuit breaker is required to operate in environments that differ from these reference conditions, correction factors must be
applied to the standard data. For example, when operating at ambient temperatures higher than 30 °C, the breaker will trip at
progressively lower currents within the designated time/current zone.
UNION ELECTRICS
Miniature Circuit Breaker
Circuit Breaker
Function
Technical Specifications
No.of poles
Rated current
Rated residual current
Rated frequency
Type of residual current
Tripping unit
Operating characteristic
Rated operating voltage
Rated insulation voltage
Rated impulse withstand voltage
Rated short circuit withstand current with fuse (inc/lΔc)
Electrical life (operation)
Mechanical life (operation)
Degree of protection (together with box)
Ambient operating temperature
Max. storage temperature
Dimensions
Colour
Assembly type (EN 60715)
Min. max. connection section
Type
In
Ue
Ui
Uimp
op.
op.
AC (V)
V
kV
KA
230 V
℃
℃
mm²
2 4
A 25,32,40,63,80,100
30, 100, 300
50-60
AC
Magnetic
General
230 400
500
6
6
6000
20000
IP 20 (IP 40)
-25 to +60
-40 to +70
35 70
80
RAL 7035
35mm DlN Rail
2.5...25
RCA-2/AC
mA
Hz
mm
mm
Width
Length
lΔ
Union Residual Current Circuit Breakers (RCCBs) – RCA-2/AC, RCA-4/AC, RCA-2/A, RCA-4/A, RCB-2/AC, RCB-4/AC, RCB-2/A+s, RCB4/A+s, RCK-2, RCK-4 protect people against indirect contact and provide additional protection against direct contact.
Furthermore, they protect installations against fire hazards caused by insulation faults. Union RCCBs are widely used in residential
installations as well as in commercial and industrial electrical distribution systems.
RCA-4/AC
2 4
25,32,40,63,80,100
30, 100, 300
50-60
A
Magnetic
General
230 400
500
6
6
6000
20000
IP 20 (IP 40)
-25 to +60
-40 to +70
35 70
80
RAL 7035
35mm DlN Rail
2.5...25
RCA-2/A RCA-4/A
2 4
25,32,40,63,80,100
30, 100, 300
50-60
AC
Magnetic
General
230 400
500
6
10
10000
20000
IP 20 (IP 40)
-25 to +60
-40 to +70
35 70
80
RAL 7035
35mm DlN Rail
2.5...25
RCB-2/AC RCB-4/AC
2 4
25,32,40,63,80,100
30, 100, 300
50-60
A
Magnetic
Delay Time Selectivity
230 400
500
6
10
10000
20000
IP 20 (IP 40)
-25 to +60
-40 to +70
35 70
80
RAL 7035
35mm DlN Rail
2.5...25
RCA-2/A+s RCA-4/A+s
2 4
25,32,40,63
30, 300
50-60
B
Magnetic
General
230 400
500
4
10
10000
20000
IP 20 (IP 40)
-25 to +60
-40 to +70
53.5 70
81.5
RAL 7035
35mm DlN Rail
2.5...25
RCK-2 RCK-4
www.unionele.com I 06
UNION ELECTRICS
Residual Current Circuit Breaker
Technical parameters
Rated current(In): 80A、100A、125A.
Rated operation voltage Ue:230V/400V~(1P),400V~(2P、3P、4P);
Rated insulation voltage Ui: 500V;
Frequency: 50/60Hz;
Thermal magnetic release: C、D;
Number of poles:1P、2P、3P、4P
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles;
Rated short-circuit breaking capacity(lcn): 6kA、10kA;
Short-circuit breaking capacity (lcs): 6kA、 10kA;
Rated impulse withstand voltage (Uimp): 4kV.
Overall and mounting dimensions (mm)
Miniature
Circuit
Breaker
Compliant standards
IEC60898-1
IEC60947-2
05 I www.unionele.com
UNION ELECTRICS
Miniature Circuit Breaker
Circuit Breaker
Function
Technical Specifications
No.of poles
Rated current
Rated residual current
Rated frequency
Type of residual current
Tripping unit
Operating characteristic
Rated operating voltage
Rated insulation voltage
Rated impulse withstand voltage
Rated short circuit withstand current with fuse (inc/lΔc)
Electrical life (operation)
Mechanical life (operation)
Degree of protection (together with box)
Ambient operating temperature
Max. storage temperature
Dimensions
Colour
Assembly type (EN 60715)
Min. max. connection section
Type
In
Ue
Ui
Uimp
op.
op.
AC (V)
V
kV
KA
230 V
℃
℃
mm²
2 4
A 25,32,40,63,80,100
30, 100, 300
50-60
AC
Magnetic
General
230 400
500
6
6
6000
20000
IP 20 (IP 40)
-25 to +60
-40 to +70
35 70
80
RAL 7035
35mm DlN Rail
2.5...25
RCA-2/AC
mA
Hz
mm
mm
Width
Length
lΔ
Union Residual Current Circuit Breakers (RCCBs) – RCA-2/AC, RCA-4/AC, RCA-2/A, RCA-4/A, RCB-2/AC, RCB-4/AC, RCB-2/A+s, RCB4/A+s, RCK-2, RCK-4 protect people against indirect contact and provide additional protection against direct contact.
Furthermore, they protect installations against fire hazards caused by insulation faults. Union RCCBs are widely used in residential
installations as well as in commercial and industrial electrical distribution systems.
RCA-4/AC
2 4
25,32,40,63,80,100
30, 100, 300
50-60
A
Magnetic
General
230 400
500
6
6
6000
20000
IP 20 (IP 40)
-25 to +60
-40 to +70
35 70
80
RAL 7035
35mm DlN Rail
2.5...25
RCA-2/A RCA-4/A
2 4
25,32,40,63,80,100
30, 100, 300
50-60
AC
Magnetic
General
230 400
500
6
10
10000
20000
IP 20 (IP 40)
-25 to +60
-40 to +70
35 70
80
RAL 7035
35mm DlN Rail
2.5...25
RCB-2/AC RCB-4/AC
2 4
25,32,40,63,80,100
30, 100, 300
50-60
A
Magnetic
Delay Time Selectivity
230 400
500
6
10
10000
20000
IP 20 (IP 40)
-25 to +60
-40 to +70
35 70
80
RAL 7035
35mm DlN Rail
2.5...25
RCA-2/A+s RCA-4/A+s
2 4
25,32,40,63
30, 300
50-60
B
Magnetic
General
230 400
500
4
10
10000
20000
IP 20 (IP 40)
-25 to +60
-40 to +70
53.5 70
81.5
RAL 7035
35mm DlN Rail
2.5...25
RCK-2 RCK-4
www.unionele.com I 06
UNION ELECTRICS
Residual Current Circuit Breaker
Technical parameters
Rated current(In): 80A、100A、125A.
Rated operation voltage Ue:230V/400V~(1P),400V~(2P、3P、4P);
Rated insulation voltage Ui: 500V;
Frequency: 50/60Hz;
Thermal magnetic release: C、D;
Number of poles:1P、2P、3P、4P
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles;
Rated short-circuit breaking capacity(lcn): 6kA、10kA;
Short-circuit breaking capacity (lcs): 6kA、 10kA;
Rated impulse withstand voltage (Uimp): 4kV.
Overall and mounting dimensions (mm)
Miniature
Circuit
Breaker
Compliant standards
IEC60898-1
IEC60947-2
05 I www.unionele.com
UNION ELECTRICS
Miniature Circuit Breaker
The summation current transformer is usually designed as a ring-shaped transformer. Permalloy is commonly used as the magnetic
material, while newer types may employ advanced magnetic materials with nanocrystalline structures. The core of a voltage-dependent
RCCB is a trip relay with a permanent magnet (PMR).
In idle state, the relay armature is held by the permanent magnet. Once current is conducted into the excitation coil, the attraction force
of the magnet is reduced, allowing the spring force to move the relay armature. Due to its simplicity and proven reliability, this type of
polarized relay is widely used.
The switching mechanism of the RCCB must be both sensitive and strong enough to ensure reliable operation of the contacts. Each load
current path must be capable of carrying the rated current throughout the service life of the device. The distance between open contacts
must provide safe insulation, and contacts must be protected from surge currents and presumed short-circuit currents.
For multi-pole types, the neutral conductor (N) contacts must close before and open after the phase conductor (L) contacts. This
prevents unwanted surge voltages in the phases.All RCCBs must be equipped with a testing device consisting of a test button (T) and a
resistor (R) appropriate to the operating voltage. The test button must be easily accessible to the user. When pressed, it simulates
residual current using the test resistor, forcing current to flow outside the summation transformer.
Standard IEC/EN 61008-1
Sinusoidal AC with rated frequency
Sinusoidal Ac and pulsating DC upto 6 mA
All kinds of current up to 1 kHz
IEC/EN 61008
IEC/ EN 61009
IEC/ EN 61008
IEC/ EN 61009
IEC/TR 60755
IEC/ EN 62423
Types Of Rccb By Sensitivity To Types Of Current
AC
A
B
RCCB type Symbols Sensitivity to residual current Properties Standards
Alternating
Alternating and pulsating
direct current
Alternating and pulsating direct
current and flat direct current
Hysteresis Curves Of Materials Of Type Ac And A Summation Current Transformers
B-magnetic induction [T]
-1 H-magnetomotoric force [Am ]
A-working point for alternate current
Type AC
Higher remanence (Br)
Type AC
Lower remanence (Br)
According to their sensitivity, RCCBs are classified into Type AC, Type A, and Type B.
Over time, additional variants have been developed to meet practical requirements.
• Type AC: Intended only for alternating residual currents. Pulsating DC components of residual current may impair sensitivity or block
tripping (IEC/EN 61008).
• Type A: Detects alternating and pulsating DC residual currents, possibly including smooth DC residual currents up to 6 mA (IEC/EN
61008).
• Type B: Detects all types of residual currents (alternating, pulsating DC, and smooth DC residual currents) (IEC/EN 62423). Type B
devices are essential in installations with frequency inverters, photovoltaic systems, and equipment with power semiconductors.
The fundamental difference between Type AC, A, and B lies in the type of material used for the core of the summation current
transformer.
Sensitivity to Various Types of Residual Currents
Summation Current Transformer and Switching Mechanism
www.unionele.com I 08
UNION ELECTRICS
Residual Current Circuit Breaker
Non-Inflammable 960℃, PA66
Overall And Mounting Dimensions (mm)
1.Actuator lever
2.Clamp terminals
3.Trip relay inside cover
4.MechanismSummation current transformer
5.Rotary system of movable contacts
6.Reset button with resistance multiplier
Test button
Earth leakage fault indicaor
Trip indicator
Ergonomic ON/OFF Lever
Functional Principle of RCCB
Every Residual Current Circuit Breaker (RCCB) has three basic components;
Toroidal current transformer, Trip relay, Switching mechanism.
The function of these components is to detect and evaluate the residual current and to interrupt the power supply if the residual current
exceeds a specified value. For correct operation of an RCCB, all live conductors of the protected circuit—or at least as many conductors as
necessary for proper appliance function—must pass through the summation current transformer.
An RCCB works on the principle of comparing currents in live conductors passing through this summation toroidal current transformer.
Under normal conditions (no phase-to-ground fault), the vector sum of instantaneous current values equals zero. The magnetic fluxes
from the various conductors cancel each other out inside the transformer core.
When an earth fault occurs, part of the current flows outside the live conductors, creating an imbalance. This imbalance induces a
magnetic flux inside the transformer core, and the output winding generates a current that activates the trip relay. The relay then triggers
the switching mechanism, causing the contacts of the RCCB to open and disconnect the circuit.
TT net work is used for
description here, but the
same applies analogously for
other net work types.
07 I www.unionele.com
UNION ELECTRICS
Residual Current Circuit Breaker
The summation current transformer is usually designed as a ring-shaped transformer. Permalloy is commonly used as the magnetic
material, while newer types may employ advanced magnetic materials with nanocrystalline structures. The core of a voltage-dependent
RCCB is a trip relay with a permanent magnet (PMR).
In idle state, the relay armature is held by the permanent magnet. Once current is conducted into the excitation coil, the attraction force
of the magnet is reduced, allowing the spring force to move the relay armature. Due to its simplicity and proven reliability, this type of
polarized relay is widely used.
The switching mechanism of the RCCB must be both sensitive and strong enough to ensure reliable operation of the contacts. Each load
current path must be capable of carrying the rated current throughout the service life of the device. The distance between open contacts
must provide safe insulation, and contacts must be protected from surge currents and presumed short-circuit currents.
For multi-pole types, the neutral conductor (N) contacts must close before and open after the phase conductor (L) contacts. This
prevents unwanted surge voltages in the phases.All RCCBs must be equipped with a testing device consisting of a test button (T) and a
resistor (R) appropriate to the operating voltage. The test button must be easily accessible to the user. When pressed, it simulates
residual current using the test resistor, forcing current to flow outside the summation transformer.
Standard IEC/EN 61008-1
Sinusoidal AC with rated frequency
Sinusoidal Ac and pulsating DC upto 6 mA
All kinds of current up to 1 kHz
IEC/EN 61008
IEC/ EN 61009
IEC/ EN 61008
IEC/ EN 61009
IEC/TR 60755
IEC/ EN 62423
Types Of Rccb By Sensitivity To Types Of Current
AC
A
B
RCCB type Symbols Sensitivity to residual current Properties Standards
Alternating
Alternating and pulsating
direct current
Alternating and pulsating direct
current and flat direct current
Hysteresis Curves Of Materials Of Type Ac And A Summation Current Transformers
B-magnetic induction [T]
-1 H-magnetomotoric force [Am ]
A-working point for alternate current
Type AC
Higher remanence (Br)
Type AC
Lower remanence (Br)
According to their sensitivity, RCCBs are classified into Type AC, Type A, and Type B.
Over time, additional variants have been developed to meet practical requirements.
• Type AC: Intended only for alternating residual currents. Pulsating DC components of residual current may impair sensitivity or block
tripping (IEC/EN 61008).
• Type A: Detects alternating and pulsating DC residual currents, possibly including smooth DC residual currents up to 6 mA (IEC/EN
61008).
• Type B: Detects all types of residual currents (alternating, pulsating DC, and smooth DC residual currents) (IEC/EN 62423). Type B
devices are essential in installations with frequency inverters, photovoltaic systems, and equipment with power semiconductors.
The fundamental difference between Type AC, A, and B lies in the type of material used for the core of the summation current
transformer.
Sensitivity to Various Types of Residual Currents
Summation Current Transformer and Switching Mechanism
www.unionele.com I 08
UNION ELECTRICS
Residual Current Circuit Breaker
Non-Inflammable 960℃, PA66
Overall And Mounting Dimensions (mm)
1.Actuator lever
2.Clamp terminals
3.Trip relay inside cover
4.MechanismSummation current transformer
5.Rotary system of movable contacts
6.Reset button with resistance multiplier
Test button
Earth leakage fault indicaor
Trip indicator
Ergonomic ON/OFF Lever
Functional Principle of RCCB
Every Residual Current Circuit Breaker (RCCB) has three basic components;
Toroidal current transformer, Trip relay, Switching mechanism.
The function of these components is to detect and evaluate the residual current and to interrupt the power supply if the residual current
exceeds a specified value. For correct operation of an RCCB, all live conductors of the protected circuit—or at least as many conductors as
necessary for proper appliance function—must pass through the summation current transformer.
An RCCB works on the principle of comparing currents in live conductors passing through this summation toroidal current transformer.
Under normal conditions (no phase-to-ground fault), the vector sum of instantaneous current values equals zero. The magnetic fluxes
from the various conductors cancel each other out inside the transformer core.
When an earth fault occurs, part of the current flows outside the live conductors, creating an imbalance. This imbalance induces a
magnetic flux inside the transformer core, and the output winding generates a current that activates the trip relay. The relay then triggers
the switching mechanism, causing the contacts of the RCCB to open and disconnect the circuit.
TT net work is used for
description here, but the
same applies analogously for
other net work types.
07 I www.unionele.com
UNION ELECTRICS
Residual Current Circuit Breaker
General
Residual Current
The RCO Series Residual Current Operated Circuit Breakers with Overcurrent Protection (RCBOs) are suitable for AC systems with a
frequency of 50/60 Hz, rated voltage 240V/415V, and rated current up to 63A. They provide protection against overloads, short circuits,
and residual currents.
The RCBO quickly disconnects the power supply if a person is at risk of electric shock or if the circuit leakage current exceeds the preset
value, ensuring the safety of both people and equipment.
RCO Series RCBOs can be applied in residential, commercial, industrial, and high-rise building installations. They are also suitable for
infrequent switching of lines under normal operating conditions.
The series includes devices classified according to detectable residual current waveforms:
Type B: Protection against sinusoidal AC residual currents, pulsed DC residual currents, alternating residual sinusoidal currents up to
1000 Hz, pulsating DC residual currents, and smooth DC residual currents, whether applied suddenly or gradually.
Type B+: Extended sensitivity version of Type B, offering protection up to higher frequency ranges (kHz level), suitable for installations
with power electronics, photovoltaic systems, and frequency converters.
Technical parameters
The tripping characteristic curves are as shown below.
B Curve C Curve
www.unionele.com I 10
UNION ELECTRICS
Residual Current Circuit Breaker With Overcurrent Protection
To prevent nuisance tripping (unwanted tripping caused by impulse voltages) due to lightning surges, switching of high-capacitance
circuits, or switching surges, RCCBs are designed with a high level of immunity to transient currents.
Resistance to Transient Surge Currents
Standard IEC/EN 61008-1
≤ 300
10-300
130-500
≤ 150
10-150
60-200
≤ 40
10-40
50-150
≤ 40
10-40
40-150
no delay - for general use
delayed with non-operation time min. 10 ms
selective-with non-operation time min.40 ms
RCCB type
Limits Of Tripping Times Of Rccb In Tests By Alternating Residual Current
Tripping times (ms)
Shape of surge current wave 8/20 μs for tests
of RCCB resis tance to unwanted tripping
Shape of standardized damped surge
current wave of 100kHz, 100/0,5μs
09 I www.unionele.com
UNION ELECTRICS
Residual Current Circuit Breaker
General
Residual Current
The RCO Series Residual Current Operated Circuit Breakers with Overcurrent Protection (RCBOs) are suitable for AC systems with a
frequency of 50/60 Hz, rated voltage 240V/415V, and rated current up to 63A. They provide protection against overloads, short circuits,
and residual currents.
The RCBO quickly disconnects the power supply if a person is at risk of electric shock or if the circuit leakage current exceeds the preset
value, ensuring the safety of both people and equipment.
RCO Series RCBOs can be applied in residential, commercial, industrial, and high-rise building installations. They are also suitable for
infrequent switching of lines under normal operating conditions.
The series includes devices classified according to detectable residual current waveforms:
Type B: Protection against sinusoidal AC residual currents, pulsed DC residual currents, alternating residual sinusoidal currents up to
1000 Hz, pulsating DC residual currents, and smooth DC residual currents, whether applied suddenly or gradually.
Type B+: Extended sensitivity version of Type B, offering protection up to higher frequency ranges (kHz level), suitable for installations
with power electronics, photovoltaic systems, and frequency converters.
Technical parameters
The tripping characteristic curves are as shown below.
B Curve C Curve
www.unionele.com I 10
UNION ELECTRICS
Residual Current Circuit Breaker With Overcurrent Protection
To prevent nuisance tripping (unwanted tripping caused by impulse voltages) due to lightning surges, switching of high-capacitance
circuits, or switching surges, RCCBs are designed with a high level of immunity to transient currents.
Resistance to Transient Surge Currents
Standard IEC/EN 61008-1
≤ 300
10-300
130-500
≤ 150
10-150
60-200
≤ 40
10-40
50-150
≤ 40
10-40
40-150
no delay - for general use
delayed with non-operation time min. 10 ms
selective-with non-operation time min.40 ms
RCCB type
Limits Of Tripping Times Of Rccb In Tests By Alternating Residual Current
Tripping times (ms)
Shape of surge current wave 8/20 μs for tests
of RCCB resis tance to unwanted tripping
Shape of standardized damped surge
current wave of 100kHz, 100/0,5μs
09 I www.unionele.com
UNION ELECTRICS
Residual Current Circuit Breaker
www.unionele.com I 12
MBC-ISO
Product Advantage
Ambient air temperature: Average ambient temperature not exceeding 35 °C within 24 hours.
Altitude: Installation site altitude not exceeding 2000 m.
Atmospheric conditions: Relative humidity not exceeding 50% at a maximum temperature of +40 °C; at +20 °C, relative humidity may
reach up to 90%.
Installation method: Standard DIN rail installation (TH35-7.5).
Pollution class: Class III.
Connection mode: Screw connection.
℃
℃
Technical Parameters
Rated current(le)
Poles
Rated voltage(Ue)
Rated insulation voltage(Ui)
Rated working current (le)
Rated impulse withstand voltage Uimp
Rated short time withstand current(lcw)
Rated short circuit making capacity(lcm)
Rated making and breaking capacity
Mechanical and electrical life
Connection wire
Operated ambient temperature
Stored ambient temperature
Pollution level
Protection level
Mounting type
Types Values
20A,25A,32A,63A,80A,100A,125A
1P、2P、3P、4P
240V1415VAC(1P),415VAC(2P、3P、4P)
400V
20A,25A,32A,63A,80A,100A.125A
4Kv(2000m)
12le, 1s
20le,0.1s
3le,1.05Ue,cosФ=0.65
Mechanical life 8500 Times
Electrical life 3000 Times
See Form 1
-5~+40
-25~+70
2
II
IP20
UNION ELECTRICS
MCB lsolator
11 I www.unionele.com
Basic Parameters
Type B Electrical B+ Electrical
Design according to
Current test marks as printed onto the device
Rated voltage Un
Rated frequency fn
Mode of operation
Operation yoltage electronic
Voltage range test circuit
Rated current ln
Rated residual
operating current
l△n
Sensitivity
Tripping Curve
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Rated conditional short-circuit current Inc
Rated making and breaking capacity lm
Peak withstand current
Electrical isolation
Endurance
(operating cycles)
Mechanical
Degree of protection
Upper and lower terminals
Temminal capacity
Terminal torque
Busbar thickness
Operating temperature
Storage- and transport temperature
Resistance to climatic conditions
Contact position indicator
Supply possibility
Mounting position
VDE 0664-400
Instantaneous
K-short time delayed (G, ASi)
S- selective
Electrical components
Mechanical components
30mA,100mA,300mA,500mA
30mA,100mA,300mA,500mA
100mA,300mA,500mA
30mA,100mA,300mA
30mA,100mA,300mA
100mA,300mA
IEC/EN 62423,IEC/EN 61009-1,OVE E8601
2P:230 240V AC
4P: 400 415V AC
50/60Hz
\"A type functionality: voltage independent
B and B+ type functionality: voltage dependent\"
50-264V AC
2P:184-264VAC
4P:184-440VAC
6A,10A,13A,16A,20A,25A,32A,40A,63A
Altemating, pulsed and smooth direct currents
High frequency up to 1 kHz High frequency up to 20kHz
B:(3-5)In, C: (5-10)ln
500 V
4 kV (1.2150μs)
6KA 10 kA
3000A
3 kA (8/20 μs) surge current proof
5 kA (8/20 μs) surge current proof for type S
>4 mm contact space
≥2000
≥ 4000
IP20
open mounted /lift terminals
2
1-25 mm
2 -2.5 Nm
0.8-2 mm
-25°C ... +55°C
-40'C ... +70°C
IEC/EN 61009
Mechanical red / green
Top or battom
Any
The Over-current Protection Characteristics
Increase to the specified current within 5s after test itema.
a
b
c
d
6~63
No.
Curve B
Curve B
Curve C
Curve C
Rated current Initial state Test current(A) Specified time(t) Expected result Remarks
Cold state
Immediately after sequence a
Cold state
Cold state
Cold state
Cold state
Cold state
Non-tripping
Tripping
Tripping
Non-tripping
Tripping
Non-tripping
Tripping
t ≥1h
t< 1h
1s<t<60s
t≥0.1s
t<0.1s
t≥0.1s
t<0.1s
1. 13 In
1. 45 In
2. 55 In
3 In
5 In
5 In
10 In
UNION ELECTRICS
Residual Current Circuit Breaker With Overcurrent Protection
www.unionele.com I 12
MBC-ISO
Product Advantage
Ambient air temperature: Average ambient temperature not exceeding 35 °C within 24 hours.
Altitude: Installation site altitude not exceeding 2000 m.
Atmospheric conditions: Relative humidity not exceeding 50% at a maximum temperature of +40 °C; at +20 °C, relative humidity may
reach up to 90%.
Installation method: Standard DIN rail installation (TH35-7.5).
Pollution class: Class III.
Connection mode: Screw connection.
℃
℃
Technical Parameters
Rated current(le)
Poles
Rated voltage(Ue)
Rated insulation voltage(Ui)
Rated working current (le)
Rated impulse withstand voltage Uimp
Rated short time withstand current(lcw)
Rated short circuit making capacity(lcm)
Rated making and breaking capacity
Mechanical and electrical life
Connection wire
Operated ambient temperature
Stored ambient temperature
Pollution level
Protection level
Mounting type
Types Values
20A,25A,32A,63A,80A,100A,125A
1P、2P、3P、4P
240V1415VAC(1P),415VAC(2P、3P、4P)
400V
20A,25A,32A,63A,80A,100A.125A
4Kv(2000m)
12le, 1s
20le,0.1s
3le,1.05Ue,cosФ=0.65
Mechanical life 8500 Times
Electrical life 3000 Times
See Form 1
-5~+40
-25~+70
2
II
IP20
UNION ELECTRICS
MCB lsolator
11 I www.unionele.com
Basic Parameters
Type B Electrical B+ Electrical
Design according to
Current test marks as printed onto the device
Rated voltage Un
Rated frequency fn
Mode of operation
Operation yoltage electronic
Voltage range test circuit
Rated current ln
Rated residual
operating current
l△n
Sensitivity
Tripping Curve
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Rated conditional short-circuit current Inc
Rated making and breaking capacity lm
Peak withstand current
Electrical isolation
Endurance
(operating cycles)
Mechanical
Degree of protection
Upper and lower terminals
Temminal capacity
Terminal torque
Busbar thickness
Operating temperature
Storage- and transport temperature
Resistance to climatic conditions
Contact position indicator
Supply possibility
Mounting position
VDE 0664-400
Instantaneous
K-short time delayed (G, ASi)
S- selective
Electrical components
Mechanical components
30mA,100mA,300mA,500mA
30mA,100mA,300mA,500mA
100mA,300mA,500mA
30mA,100mA,300mA
30mA,100mA,300mA
100mA,300mA
IEC/EN 62423,IEC/EN 61009-1,OVE E8601
2P:230 240V AC
4P: 400 415V AC
50/60Hz
\"A type functionality: voltage independent
B and B+ type functionality: voltage dependent\"
50-264V AC
2P:184-264VAC
4P:184-440VAC
6A,10A,13A,16A,20A,25A,32A,40A,63A
Altemating, pulsed and smooth direct currents
High frequency up to 1 kHz High frequency up to 20kHz
B:(3-5)In, C: (5-10)ln
500 V
4 kV (1.2150μs)
6KA 10 kA
3000A
3 kA (8/20 μs) surge current proof
5 kA (8/20 μs) surge current proof for type S
>4 mm contact space
≥2000
≥ 4000
IP20
open mounted /lift terminals
2
1-25 mm
2 -2.5 Nm
0.8-2 mm
-25°C ... +55°C
-40'C ... +70°C
IEC/EN 61009
Mechanical red / green
Top or battom
Any
The Over-current Protection Characteristics
Increase to the specified current within 5s after test itema.
a
b
c
d
6~63
No.
Curve B
Curve B
Curve C
Curve C
Rated current Initial state Test current(A) Specified time(t) Expected result Remarks
Cold state
Immediately after sequence a
Cold state
Cold state
Cold state
Cold state
Cold state
Non-tripping
Tripping
Tripping
Non-tripping
Tripping
Non-tripping
Tripping
t ≥1h
t< 1h
1s<t<60s
t≥0.1s
t<0.1s
t≥0.1s
t<0.1s
1. 13 In
1. 45 In
2. 55 In
3 In
5 In
5 In
10 In
UNION ELECTRICS
Residual Current Circuit Breaker With Overcurrent Protection
Outline dimension
TechnicalParameters
36.5
90
66
50
46
Remote communication alarm
Remote communication wiring
Open/Close Contact Terminals
Maximum 1.5mm single /flexible wire
IEC TYPE
SPECS
Nominal voltage(Un)
Maximum Continuous Operating Voltage(Uc)
Nominal Discharge Current(In)8/20μs
Maximum Discharge Current(Imax)8/20μs
Voltage Protection Level(Up)8/20μs
Short-circuit Current Rating(Iscpv)
Response Time
Indication
Connection cross-section
Din Rail Installation
Temperature range
Shell Material
Protect Rating
Standard
L-N
N-PE
L-PEN
L-N
N-PE
L-N
N-PE
L-N
I,T1
1P 2P 3P 4P
220V AC
I,T1
380V AC
275V AC
275V AC
275V AC
275V AC
275V AC
......
385V AC
......
385V AC
385V AC
385V AC
......
1P 2P 3P 4P
220V AC 380V AC
275V AC
275V AC
275V AC
275V AC
275V AC
......
385V AC
......
385V AC
385V AC
385V AC
......
15kA
15kA
1.8kV
1.8kV
25kA
≤25ns
Green:Normal Red:Failure
4-35mm²
35mm(EN50022/DIN46277-3)
-40~70℃
Plastic to UL91V-00
Ip20
IEC 61643-1
25kA
25kA
2.0kV
2.0kV
25kA
≤25ns
Green:Normal Red:Failure
4-35mm²
35mm(EN50022/DIN46277-3)
-40~70℃
Plastic to UL91V-0
Ip20
IEC 61643-1
Open/Close Contact Terminals
Maximum 1.5mm single/flexible wire
UN-A15 UN-A25
www.unionele.com I 14
UNION ELECTRICS
Surge Protector Device
Productadvantage
Multilayer spark gap device Integrated surge protector unit
Highest to withstand 50kA(10/350us)lightning shock
Action response time is less than 100ns
kP k kR m
P 14
11 el
kP k kR m
P 14
11 el
L1、L2、L3、N、PE(4+0circuit) L1、L2、L3、N、PE(3+1circuit)
Surge
Protector
Device
13 I www.unionele.com
UNION ELECTRICS
Surge Protector Device
UN-B100
Outline dimension
TechnicalParameters
36.5
90
66
50
46
Remote communication alarm
Remote communication wiring
Open/Close Contact Terminals
Maximum 1.5mm single /flexible wire
IEC TYPE
SPECS
Nominal voltage(Un)
Maximum Continuous Operating Voltage(Uc)
Nominal Discharge Current(In)8/20μs
Maximum Discharge Current(Imax)8/20μs
Voltage Protection Level(Up)8/20μs
Short-circuit Current Rating(Iscpv)
Response Time
Indication
Connection cross-section
Din Rail Installation
Temperature range
Shell Material
Protect Rating
Standard
L-N
N-PE
L-PEN
L-N
N-PE
L-N
N-PE
L-N
I,T1
1P 2P 3P 4P
220V AC
I,T1
380V AC
275V AC
275V AC
275V AC
275V AC
275V AC
......
385V AC
......
385V AC
385V AC
385V AC
......
1P 2P 3P 4P
220V AC 380V AC
275V AC
275V AC
275V AC
275V AC
275V AC
......
385V AC
......
385V AC
385V AC
385V AC
......
15kA
15kA
1.8kV
1.8kV
25kA
≤25ns
Green:Normal Red:Failure
4-35mm²
35mm(EN50022/DIN46277-3)
-40~70℃
Plastic to UL91V-00
Ip20
IEC 61643-1
25kA
25kA
2.0kV
2.0kV
25kA
≤25ns
Green:Normal Red:Failure
4-35mm²
35mm(EN50022/DIN46277-3)
-40~70℃
Plastic to UL91V-0
Ip20
IEC 61643-1
Open/Close Contact Terminals
Maximum 1.5mm single/flexible wire
UN-A15 UN-A25
www.unionele.com I 14
UNION ELECTRICS
Surge Protector Device
Productadvantage
Multilayer spark gap device Integrated surge protector unit
Highest to withstand 50kA(10/350us)lightning shock
Action response time is less than 100ns
kP k kR m
P 14
11 el
kP k kR m
P 14
11 el
L1、L2、L3、N、PE(4+0circuit) L1、L2、L3、N、PE(3+1circuit)
Surge
Protector
Device
13 I www.unionele.com
UNION ELECTRICS
Surge Protector Device
UN-B100
Outline dimension
Type
TechnicalParameters
18
90
66
50
46
Rated voltage (max.continuous a.c.voltage) [Uc]
Nominal discharge current (8/20) [ ln ]
Maximum discharge current [ Imax ]
Voltage protection level [ Up ]
Response time [ tA]
Max.backup fuse
Operating temperature range [Tup]
Cross-sectional area
Mounting on
Enclosure material
Dimension
Test standards
Certification
Type of remote signalling contact
Switching capacity a.c
Switching capacity d.c
Cross-sectional area for remote signalling contact
800VDC / 1000VDC / 1200VDC
20kA
40kA
3.2kV / 4.0kV / 4.4kV
≤25ns
125A gL/gG
-40℃...+60℃
2 2 2
1.5mm ~2.5mm solid / 35mm flexible
35mm DIN rail
Purple (module) / light gray (base) thermoplastic,UL94-V0
1 mods
IEC 61643-1; YD/T 1235.1
CE ROHS ISO9001 TUV
Switching contact
250V / 0.5A
250V / 0.1A; 125v/0.2A; 75v/0.5A
2 Max. 1.5mm solid / flexible
Type WR-T1T2-DC / 2P
Packing unit
Weight
1pc(s)
206g
WR-T1T2-DC / 3P
1pc(s)
283g
UN-T2-DC / 2P UN-T2-DC / 3P
www.unionele.com I 16
UNION ELECTRICS
Surge Protector Device
DC+ DC3
2RM
1
PE
3
2RM
1
DC+ PE DCPluggable module, easy for installation and maintenance
High discharge capacity, quick response
Double thermal disconnection devices,provide more reliable protection
Multifunctional terminals for connection of conductorsand busbars
Green window will change when fault occurs,also provide remote alarm terminal
For installation at LPZ OA-1 or higher, protecting d.c power supply system from surge damages. Applied in pluggable SPD Class l+ll(Class B+C) for
various d.c.power supply system. Designed according to lEC 61643-1.
Productadvantage
Surge
Protector
Device
15 I www.unionele.com
UNION ELECTRICS
Surge Protector Device
Outline dimension
Type
TechnicalParameters
18
90
66
50
46
Rated voltage (max.continuous a.c.voltage) [Uc]
Nominal discharge current (8/20) [ ln ]
Maximum discharge current [ Imax ]
Voltage protection level [ Up ]
Response time [ tA]
Max.backup fuse
Operating temperature range [Tup]
Cross-sectional area
Mounting on
Enclosure material
Dimension
Test standards
Certification
Type of remote signalling contact
Switching capacity a.c
Switching capacity d.c
Cross-sectional area for remote signalling contact
800VDC / 1000VDC / 1200VDC
20kA
40kA
3.2kV / 4.0kV / 4.4kV
≤25ns
125A gL/gG
-40℃...+60℃
2 2 2
1.5mm ~2.5mm solid / 35mm flexible
35mm DIN rail
Purple (module) / light gray (base) thermoplastic,UL94-V0
1 mods
IEC 61643-1; YD/T 1235.1
CE ROHS ISO9001 TUV
Switching contact
250V / 0.5A
250V / 0.1A; 125v/0.2A; 75v/0.5A
2 Max. 1.5mm solid / flexible
Type WR-T1T2-DC / 2P
Packing unit
Weight
1pc(s)
206g
WR-T1T2-DC / 3P
1pc(s)
283g
UN-T2-DC / 2P UN-T2-DC / 3P
www.unionele.com I 16
UNION ELECTRICS
Surge Protector Device
DC+ DC3
2RM
1
PE
3
2RM
1
DC+ PE DCPluggable module, easy for installation and maintenance
High discharge capacity, quick response
Double thermal disconnection devices,provide more reliable protection
Multifunctional terminals for connection of conductorsand busbars
Green window will change when fault occurs,also provide remote alarm terminal
For installation at LPZ OA-1 or higher, protecting d.c power supply system from surge damages. Applied in pluggable SPD Class l+ll(Class B+C) for
various d.c.power supply system. Designed according to lEC 61643-1.
Productadvantage
Surge
Protector
Device
15 I www.unionele.com
UNION ELECTRICS
Surge Protector Device
Product Characteristics
Reliability
The closed structure design further
protects the rotating and moving
conductors from the external
environments and makes the electrical
contacts more reliable.
High Performance
Gas-producing material is adopted in the
module to produce gas flow when the
gas-producing short-circuit current is
generated. Obviously improve the effect
of air blowing, to achieve a better current
limiting effect, the product break index
increased significantly.
Security
The module housing is made of highstrength heat-resistant material. Achieve
electrical isolation between phases and
operating mechanisms. To ensure the
safety of users and eliminate phase-tophase current short circuit.
www.unionele.com I 18
UNION ELECTRICS
Molded Case Circuit Breaker
Rated Voltage
Rated Frequency
Rated Insulation Voltage
Rated Impulse Voltage
Instantaneous/Short Time Current
Rated Ultimate Breaking Capacity
Rated Service Breaking Capacity
Utilization Category
Residual Current(I△n) Setting
Residual Trip Time Setting
Monthly Test Button
Long-Time Current Setting
Leakage Indication Light
Trip Button
Lock Setting For The Operating Handle
Stream Cable Connections
Molded Case
Circuit
Breaker
General
Product Advantage
This switch is designed for opening and closing circuits in standard switching
applications. It has a breaking capacity range of 18 kA to 50 kA, available in
both fixed and adjustable versions, with rated current options ranging from
16 A to 250 A.
Dual rotary contact structure: The UN Series employs a dual rotary contact design with an energy release system to provide stable,
reliable protection and excellent current-limiting performance.
Protective transparent cover: The transparent aluminum cover safeguards the trip unit and allows the installation of rotary handles,
motor operation mechanisms, and other accessories.
Altitude suitability: Designed for installation at sites with altitudes up to 2,000 m.
Operating temperature range: –25 °C to +70 °C. For ambient temperatures above +40 °C (or +65 °C for circuit breakers protecting
motor feeders), derating is required.
Environmental durability: Resistant to humid air, salt spray, oil mist, and mold.
Safe installation: Must be installed in environments free of explosion hazards, conductive dust, or substances that could corrode metal
or damage insulation.
Outdoor conditions: Suitable for use in locations without direct exposure to rain or snow.
Pollution degree: Class 3.
Installation category: Category III.
17 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
Fixed Type Adjustable Type Adjustable-Leakage Type
Product Characteristics
Reliability
The closed structure design further
protects the rotating and moving
conductors from the external
environments and makes the electrical
contacts more reliable.
High Performance
Gas-producing material is adopted in the
module to produce gas flow when the
gas-producing short-circuit current is
generated. Obviously improve the effect
of air blowing, to achieve a better current
limiting effect, the product break index
increased significantly.
Security
The module housing is made of highstrength heat-resistant material. Achieve
electrical isolation between phases and
operating mechanisms. To ensure the
safety of users and eliminate phase-tophase current short circuit.
www.unionele.com I 18
UNION ELECTRICS
Molded Case Circuit Breaker
Rated Voltage
Rated Frequency
Rated Insulation Voltage
Rated Impulse Voltage
Instantaneous/Short Time Current
Rated Ultimate Breaking Capacity
Rated Service Breaking Capacity
Utilization Category
Residual Current(I△n) Setting
Residual Trip Time Setting
Monthly Test Button
Long-Time Current Setting
Leakage Indication Light
Trip Button
Lock Setting For The Operating Handle
Stream Cable Connections
Molded Case
Circuit
Breaker
General
Product Advantage
This switch is designed for opening and closing circuits in standard switching
applications. It has a breaking capacity range of 18 kA to 50 kA, available in
both fixed and adjustable versions, with rated current options ranging from
16 A to 250 A.
Dual rotary contact structure: The UN Series employs a dual rotary contact design with an energy release system to provide stable,
reliable protection and excellent current-limiting performance.
Protective transparent cover: The transparent aluminum cover safeguards the trip unit and allows the installation of rotary handles,
motor operation mechanisms, and other accessories.
Altitude suitability: Designed for installation at sites with altitudes up to 2,000 m.
Operating temperature range: –25 °C to +70 °C. For ambient temperatures above +40 °C (or +65 °C for circuit breakers protecting
motor feeders), derating is required.
Environmental durability: Resistant to humid air, salt spray, oil mist, and mold.
Safe installation: Must be installed in environments free of explosion hazards, conductive dust, or substances that could corrode metal
or damage insulation.
Outdoor conditions: Suitable for use in locations without direct exposure to rain or snow.
Pollution degree: Class 3.
Installation category: Category III.
17 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
Fixed Type Adjustable Type Adjustable-Leakage Type
UNA Adjustable Type
10-16A、16-20A、20-25A、25-32A、32-40A、40-50A、
50-63A、63-80A、80-100A、100-125A、125-160A
100-125A、125-160A、
160-200A、200-250A In
Ue
Ui
Uimp
Icu
s
UNA-250
-
H
UNA-160
www.unionele.com I 20
UNION ELECTRICS
Molded Case Circuit Breaker
50*60*140
75*60*140
100*60*140
-
105*60*175
140*60*175
H
W L
W*L*H(mm)
UNF Fixed Type
In
Ue
Ui
Uimp
Icu
s
UNF-250
-
H
UNF-160
H
W L
W*L*H(mm)
19 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
50*60*140
75*60*140
100*60*140
-
105*60*175
140*60*175
UNA Adjustable Type
10-16A、16-20A、20-25A、25-32A、32-40A、40-50A、
50-63A、63-80A、80-100A、100-125A、125-160A
100-125A、125-160A、
160-200A、200-250A In
Ue
Ui
Uimp
Icu
s
UNA-250
-
H
UNA-160
www.unionele.com I 20
UNION ELECTRICS
Molded Case Circuit Breaker
50*60*140
75*60*140
100*60*140
-
105*60*175
140*60*175
H
W L
W*L*H(mm)
UNF Fixed Type
In
Ue
Ui
Uimp
Icu
s
UNF-250
-
H
UNF-160
H
W L
W*L*H(mm)
19 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
50*60*140
75*60*140
100*60*140
-
105*60*175
140*60*175
Built-out Accessory
Built-Out Accessory
Short Terminal Cover
Inter-phase Insulation Barrier
Copper connection bar is connection accessories, which is used to connect wire/cable or
any other conductor together with MCCB/ELCB series.
They are suitable for same phase and same ampere frame of both MCCB/ELCB series
Copper Connection Bar(CCB)
Short terminal cover is insulation accessory ,which is used to prevent the direct contact
between the terminal in circuit breaker and other live parts to ensure the safety of the users.
All the terminal cover is designed with holes which can be knocked off to connect the cables
of various wires and the copper platens.
They are compatible with both the interphase insulation barrier and suitable for same
phase& ampere frame of both MCCB/ELCB series .
Inter-phase insulation barrier is safety accessory, which is used for the insulation between the
phases. lt can guarantee the best insulation of the wiring terminal.
They are compatible with the short terminal covers. And it is OK to mount the inter-phase
insulation barrier in both UN series and every phase(2P,3P and 4P).
Inter-phase Insulation Barrier
Short Terminal Cover
www.unionele.com I 22
UNION ELECTRICS
Molded Case Circuit Breaker
DML Adjustable-Leakage Type
Icu
s
Ue
Ui
Uimp
I n
In
I n
I no
I n
100-125A、125-160A、
160-200A、200-250A
10-16A、16-20A、20-25A、25-32A、32-40A、40-50A、
50-63A、63-80A、80-100A、100-125A
UNL-125 UNL-250
690V
6
21 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
~
50*60*140
75*60*140
100*60*140
-
105*60*175
140*60*175
H
W L
W*L*H(mm)
Built-out Accessory
Built-Out Accessory
Short Terminal Cover
Inter-phase Insulation Barrier
Copper connection bar is connection accessories, which is used to connect wire/cable or
any other conductor together with MCCB/ELCB series.
They are suitable for same phase and same ampere frame of both MCCB/ELCB series
Copper Connection Bar(CCB)
Short terminal cover is insulation accessory ,which is used to prevent the direct contact
between the terminal in circuit breaker and other live parts to ensure the safety of the users.
All the terminal cover is designed with holes which can be knocked off to connect the cables
of various wires and the copper platens.
They are compatible with both the interphase insulation barrier and suitable for same
phase& ampere frame of both MCCB/ELCB series .
Inter-phase insulation barrier is safety accessory, which is used for the insulation between the
phases. lt can guarantee the best insulation of the wiring terminal.
They are compatible with the short terminal covers. And it is OK to mount the inter-phase
insulation barrier in both UN series and every phase(2P,3P and 4P).
Inter-phase Insulation Barrier
Short Terminal Cover
www.unionele.com I 22
UNION ELECTRICS
Molded Case Circuit Breaker
DML Adjustable-Leakage Type
Icu
s
Ue
Ui
Uimp
I n
In
I n
I no
I n
100-125A、125-160A、
160-200A、200-250A
10-16A、16-20A、20-25A、25-32A、32-40A、40-50A、
50-63A、63-80A、80-100A、100-125A
UNL-125 UNL-250
690V
6
21 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
~
50*60*140
75*60*140
100*60*140
-
105*60*175
140*60*175
H
W L
W*L*H(mm)
Built-in Accessory(UNA/UNF)
SHT
AX
AL
AX+AX
AX+AL
AX+AX
AX
AX AL SHT AX+AX AX+AL
Left hole position Right hole position
Standard AX AL SHT AX+AX AX+AL
Type Pole
UNA-160
UNF-160
Maximum Possibilities
3P
4P
3P
4P
UNL-125
3P
4P
UNL-250
www.unionele.com I 24
UNION ELECTRICS
Molded Case Circuit Breaker
3P
4P
UNA-250
UNF-250
Built-in Accessory
Shunt trip (SHT)
The shunt trip is an accessory for remote control.
The shunt will trip when the input voltage is 70% - 110% of the rated operational voltage.(US)
Auxiliary switch (AX)(1NO+1NC)
Auxiliary switch is used to indicate the “On\" and “Off\" status of the breaker
Each switch has two contacts with a common connection.
One is open and the other closed when the circuit breaker is open, and vice versa.
Combination switch(AX+AL)
It has one auxiliary switch(AX) and one alarm switch(AL) in a body to connect into the same
position of the breaker.
Alarm switch(AL)
Alarm switch will make immediate audio or visual indication in a tripped breaker due to
overload, short circuit or shunt trip to remind people.
This switch features a closed contact when the circuit breaker is tripped automatically.
In other words, this switch does not function when the breaker is operated manually
Combination switch(AX+AX)(2NO+2NC)
It has two auxiliary switch(AX) in a body to connect into the same position of the breaker.
MCCB ON OFF TRIP
Contact(AX+AL)
AX
AL
AXc1
AXa1
AXb1
AXc1
AXa1
AXb1
AXc1
AXa1
AXb1
AXc1
AXa1
AXb1
23 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
Built-in Accessory(UNA/UNF)
SHT
AX
AL
AX+AX
AX+AL
AX+AX
AX
AX AL SHT AX+AX AX+AL
Left hole position Right hole position
Standard AX AL SHT AX+AX AX+AL
Type Pole
UNA-160
UNF-160
Maximum Possibilities
3P
4P
3P
4P
UNL-125
3P
4P
UNL-250
www.unionele.com I 24
UNION ELECTRICS
Molded Case Circuit Breaker
3P
4P
UNA-250
UNF-250
Built-in Accessory
Shunt trip (SHT)
The shunt trip is an accessory for remote control.
The shunt will trip when the input voltage is 70% - 110% of the rated operational voltage.(US)
Auxiliary switch (AX)(1NO+1NC)
Auxiliary switch is used to indicate the “On\" and “Off\" status of the breaker
Each switch has two contacts with a common connection.
One is open and the other closed when the circuit breaker is open, and vice versa.
Combination switch(AX+AL)
It has one auxiliary switch(AX) and one alarm switch(AL) in a body to connect into the same
position of the breaker.
Alarm switch(AL)
Alarm switch will make immediate audio or visual indication in a tripped breaker due to
overload, short circuit or shunt trip to remind people.
This switch features a closed contact when the circuit breaker is tripped automatically.
In other words, this switch does not function when the breaker is operated manually
Combination switch(AX+AX)(2NO+2NC)
It has two auxiliary switch(AX) in a body to connect into the same position of the breaker.
MCCB ON OFF TRIP
Contact(AX+AL)
AX
AL
AXc1
AXa1
AXb1
AXc1
AXa1
AXb1
AXc1
AXa1
AXb1
AXc1
AXa1
AXb1
23 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
In 225、250、315、
350、400 400、500、630 630、700、800
Rated insulation Voltage Ui
Rated Operating Voltage Ue
Rated impulse Withstand Voltage Uimp
Arcing Distance(mm)
Breaking Capacity Level
AC1000
AC400/AC690
12000
100
M
Rated Ultimate Short-Circuit
Breaking Capacity lcu (kA) AC400V
Rated Service Short-Circuit
Breaking Capacity lcs(kA) AC400V
500
2500
3000
1000
4000
5000
1000
4000
5000
Powered on
Powered off
Total count
Operating Performance (time)
H
15
70 75
M H M H
15
70 75
20
75
UNF-400
UNA-400
UNF-630
UNA-630
UNF-800
UNA-800
20
70 100
20
70 100
30
75
75
100
-
150*149*257
198*149*257
-
185*155*270
240*155*270
-
210*160*280
280*160*280
UNA Adjustable Type
UNF Fixed Type
UNF-800
IEC 60947-2
TS EN 60947-2
800A
Molded Case
Circuit Breaker
50kA
100%Icu
400/415V~
800V~
8kV~
50-60Hz
+40℃
Icu
Ics
Ue
Ui
Uimp
Fn
Cat.A
Molded Case
Circuit Breaker
I >
Ir
Im 8000A
±20%
800A
AC690V
AC690V
www.unionele.com I 26
UNION ELECTRICS
Molded Case Circuit Breaker
H
W L
W*L*H(mm)
Model
Outline Dimensions
UN 125/160 Series
UN 250 Series
25 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
Thermal Magnetic Accessories
Description
1NO+1NC Aux.Contact for UNA/UNF/UNL Series
2NO+2NC Aux.Contact for UNA/UNF/UNL Series
Alarm contact for UNA/UNF/UNL Series
230 V AC shunt trip coil for UNA/UNF/UNL Series
In 225、250、315、
350、400 400、500、630 630、700、800
Rated insulation Voltage Ui
Rated Operating Voltage Ue
Rated impulse Withstand Voltage Uimp
Arcing Distance(mm)
Breaking Capacity Level
AC1000
AC400/AC690
12000
100
M
Rated Ultimate Short-Circuit
Breaking Capacity lcu (kA) AC400V
Rated Service Short-Circuit
Breaking Capacity lcs(kA) AC400V
500
2500
3000
1000
4000
5000
1000
4000
5000
Powered on
Powered off
Total count
Operating Performance (time)
H
15
70 75
M H M H
15
70 75
20
75
UNF-400
UNA-400
UNF-630
UNA-630
UNF-800
UNA-800
20
70 100
20
70 100
30
75
75
100
-
150*149*257
198*149*257
-
185*155*270
240*155*270
-
210*160*280
280*160*280
UNA Adjustable Type
UNF Fixed Type
UNF-800
IEC 60947-2
TS EN 60947-2
800A
Molded Case
Circuit Breaker
50kA
100%Icu
400/415V~
800V~
8kV~
50-60Hz
+40℃
Icu
Ics
Ue
Ui
Uimp
Fn
Cat.A
Molded Case
Circuit Breaker
I >
Ir
Im 8000A
±20%
800A
AC690V
AC690V
www.unionele.com I 26
UNION ELECTRICS
Molded Case Circuit Breaker
H
W L
W*L*H(mm)
Model
Outline Dimensions
UN 125/160 Series
UN 250 Series
25 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
Thermal Magnetic Accessories
Description
1NO+1NC Aux.Contact for UNA/UNF/UNL Series
2NO+2NC Aux.Contact for UNA/UNF/UNL Series
Alarm contact for UNA/UNF/UNL Series
230 V AC shunt trip coil for UNA/UNF/UNL Series
Thermal Magnetic Accessories
UNA630
UNF630
UNA800
UNF800
UNA400
UNF400
Model Poles
Overall dimensions(mm) Installation dimensions(mm)
Thermal Magnetic Accessories
UNL-400
Model Poles
Overall dimensions(mm) Installation dimensions(mm)
106
116
106
116
116
116
146
146
UNL-630
UNL-800
Outline Dimensions
Outline Dimensions
www.unionele.com I 28
UNION ELECTRICS
Molded Case Circuit Breaker
W L3
L4
W
H
H
W H
H
H
L3
L4
W W
W H
L
50
35
M H
65
42
100
65
100/300/500
100/300/500
5I△n
0.04
0.4/1
Non-delay type
Delayed type
Residual current protection action time
Delayed type
Non-delay type
Rated residual
operating current
Maximum
breaking time
L
50
35
M H
65
42
100
65
L M H
300/500/1000
300/500/1000
10I△n
0.04
0.4/1
0.04
0.4/1
50
35
65
42
100
65
300/500/1000
300/500/1000
10I△n
UNL-400 UNL-630 UNL-800
In 225、250、315、
350、400 400、500、630 630、700、800
Rated insulation Voltage Ui
Rated Operating Voltage Ue
Rated impulse Withstand Voltage Uimp
Arcing Distance(mm)
Breaking Capacity Level
800
AC400
8000
100
Rated Ultimate Short-Circuit
Breaking Capacity lcu (kA) AC400V
Rated Service Short-Circuit
Breaking Capacity lcs(kA) AC400V
500
2500
3000
1000
4000
5000
1000
4000
5000
Powered on
Powered off
Total count
Operating Performance (time)
-
257*149*150
257*149*198
-
270*155*185
270*155*240
-
280*160*210
280*160*280
UNL Adjustable-Leakage Type
300
PUSH TO TRIP
I n 100 500mA
0.4
ts 0.1 1s
Leakage
Indicator
KAÇAK AKIM
TEST
Icu
Ics
Ui
Ue
Uimp
Cat.A
400V~50kA
400V~100%Icu
800V~50-60Hz
400V~50-60Hz
8kV
+40℃
IEC 60947-2
TS EN 60947-2
UNL-800
Molded Case Circuit Breaker
Kaçak Akım Korumalı
Termik Manyetik Şalter
800A
~
27 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
H
W L
W*L*H(mm)
Model
Thermal Magnetic Accessories
UNA630
UNF630
UNA800
UNF800
UNA400
UNF400
Model Poles
Overall dimensions(mm) Installation dimensions(mm)
Thermal Magnetic Accessories
UNL-400
Model Poles
Overall dimensions(mm) Installation dimensions(mm)
106
116
106
116
116
116
146
146
UNL-630
UNL-800
Outline Dimensions
Outline Dimensions
www.unionele.com I 28
UNION ELECTRICS
Molded Case Circuit Breaker
W L3
L4
W
H
H
W H
H
H
L3
L4
W W
W H
L
50
35
M H
65
42
100
65
100/300/500
100/300/500
5I△n
0.04
0.4/1
Non-delay type
Delayed type
Residual current protection action time
Delayed type
Non-delay type
Rated residual
operating current
Maximum
breaking time
L
50
35
M H
65
42
100
65
L M H
300/500/1000
300/500/1000
10I△n
0.04
0.4/1
0.04
0.4/1
50
35
65
42
100
65
300/500/1000
300/500/1000
10I△n
UNL-400 UNL-630 UNL-800
In
225、250、315、
350、400
400、500、630 630、700、800
Rated insulation Voltage Ui
Rated Operating Voltage Ue
Rated impulse Withstand Voltage Uimp
Arcing Distance(mm)
Breaking Capacity Level
800
AC400
8000
100
Rated Ultimate Short-Circuit
Breaking Capacity lcu (kA)
AC400V
Rated Service Short-Circuit
Breaking Capacity lcs(kA)
AC400V
500
2500
3000
1000
4000
5000
1000
4000
5000
Powered on
Powered off
Total count
Operating Performance (time)
-
257*149*150
257*149*198
-
270*155*185
270*155*240
-
280*160*210
280*160*280
UNL Adjustable-Leakage Type
300
PUSH TO TRIP
I n 100 500mA
0.4
ts 0.1 1s
Leakage
Indicator
KAÇAK AKIM
TEST
Icu
Ics
Ui
Ue
Uimp
Cat.A
400V~50kA
400V~100%Icu
800V~50-60Hz
400V~50-60Hz
8kV
+40℃
IEC 60947-2
TS EN 60947-2
UNL-800
Molded Case Circuit Breaker
Kaçak Akım Korumalı
Termik Manyetik Şalter
800A
~
27 I www.unionele.com
UNION ELECTRICS
Molded Case Circuit Breaker
H
W L
W*L*H(mm)
Model
DC MCCB
Vertical installation
Horizontal installation
Model
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
2POutline(Pic1) 3POutline(Pic2) 2POutline(Pic1) 2POutline(Pic1) 3POutline(Pic2)
Available
Method of mounting
This series of circuit breakers is generally installed vertically but can also be installed horizontally (refer to the picture below).
UNION ELECTRICS
Molded Case Circuit Breaker
Frame current
Rated current
Rated insulation
voltage
Rated impulse
withstand voltage
Type
Rated
operational
voltage
Rated Ultimate
Short-circuit
Breaking Capacity
Rated service short-circuit
breaking capacity
Connection Method
Isolation Function
Utilization Category
Mechanical Life
Electrical Life
Arcing Distance
Dimensions
Reference Ambient
Temperature
Times
Times
www.unionele.com I 30
DC MCCB
DC MCCB
UNION ELECTRICS
Molded Case Circuit Breaker
UNDC-800/3300
Main Technical Data
Model
Frame current
Rated current
Rated insulation
voltage
Rated impulse
withstand voltage
Type
Rated
operational
voltage
Rated Ultimate
Short-circuit
Breaking Capacity
Rated service short-circuit
breaking capacity
Connection Method
Isolation Function
Utilization Category
Mechanical Life
Electrical Life
Arcing Distance
Dimensions
Reference Ambient
Temperature
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
2PExternal Dimensions(Pic1)
3PExternal Dimensions(Pic2)
2PExternal Dimensions(Pic1)
3PExternal Dimensions(Pic3) 2PExternal Dimensions(Pic1)
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
Times
Times
Available
63,80,100,140,
125,160,180,
200,225,250
280,300,315 250,315,350
400
250,315,350
400
29 I www.unionele.com
DC MCCB
Vertical installation
Horizontal installation
Model
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
2POutline(Pic1) 3POutline(Pic2) 2POutline(Pic1) 2POutline(Pic1) 3POutline(Pic2)
Available
Method of mounting
This series of circuit breakers is generally installed vertically but can also be installed horizontally (refer to the picture below).
UNION ELECTRICS
Molded Case Circuit Breaker
Frame current
Rated current
Rated insulation
voltage
Rated impulse
withstand voltage
Type
Rated
operational
voltage
Rated Ultimate
Short-circuit
Breaking Capacity
Rated service short-circuit
breaking capacity
Connection Method
Isolation Function
Utilization Category
Mechanical Life
Electrical Life
Arcing Distance
Dimensions
Reference Ambient
Temperature
Times
Times
www.unionele.com I 30
DC MCCB
DC MCCB
UNION ELECTRICS
Molded Case Circuit Breaker
UNDC-800/3300
Main Technical Data
Model
Frame current
Rated current
Rated insulation
voltage
Rated impulse
withstand voltage
Type
Rated
operational
voltage
Rated Ultimate
Short-circuit
Breaking Capacity
Rated service short-circuit
breaking capacity
Connection Method
Isolation Function
Utilization Category
Mechanical Life
Electrical Life
Arcing Distance
Dimensions
Reference Ambient
Temperature
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
2PExternal Dimensions(Pic1)
3PExternal Dimensions(Pic2)
2PExternal Dimensions(Pic1)
3PExternal Dimensions(Pic3)
2PExternal Dimensions(Pic1)
2PExter
nal
Dimensi
ons
3PExter
nal
Dimensi
ons
Times
Times
Available
63,80,100,140,
125,160,180,
200,225,250
280,300,315
250,315,350
400
250,315,350
400
29 I www.unionele.com
UNDM-400(3P)
PUSH TO TRIP
142
47 48
52.9
32.7
57.1
30
48
96
150
257
78.5
108 25 77.8
524.6307
140 70.4 57.5
16.5
6-M10*30 31
119
39
36.5
118
120.5
122.3
125.8
156.2
UNDM-630、800(3P)
PUSH TO TRIP
526.3 350320285.5 275
135
84.3
270 58.5
25 70.2
320
37
182
62
53
47.5
41
58.5
58
116
6-M12*3518
134.5
119
118
29
36
120.5
122.3
125.8
158
UNION ELECTRICS
Molded Case Circuit Breaker
www.unionele.com I 32
UNDM5DC-250
UNDM5DC-315
UNDM5DC-400
UNDM5DC-400V
UNDM5DC-630
UNDM5DC-630V
UNDM5DC-800
Hold Characteristics
The circuit breaker's thermal-actuated release has a unique inverse time-delay characteristic; the electromagnetic release is instantaneous in action, and its
characteristics are detailed in the table below
For power distribution
Rated Current (A)
Thermal release(ambient temperature +40℃)
Non-operation time at 1.05 times
rated current (cold state) in hours
Operation time at 1.3 times rated
current (hot state) in hours
Model Current when energized(A) Total Power Loss for Three-phase/Four-phase(W)
Power loss table
Outline Dimensions
UNDM-250、315(3P)
LINE 1 3 5
OFF
2 4 6
107
36
98.38046.3
408363.8 343.8
50.8 34.7
19.5
20.5 200167.5
26
42.5
23.5
PUSH TO TRIR
LOAD
38.5
35
51.5
6-M8*20
70
95
99
98
26
26 102
104
109
135.2
Phase barrier
UNDM-250、315(2P)
UNION ELECTRICS
Molded Case Circuit Breaker
31 I www.unionele.com
UNDM-400(3P)
PUSH TO TRIP
142
47 48
52.9
32.7
57.1
30
48
96
150
257
78.5
108 25 77.8
524.6307
140 70.4 57.5
16.5
6-M10*30 31
119
39
36.5
118
120.5
122.3
125.8
156.2
UNDM-630、800(3P)
PUSH TO TRIP
526.3 350320285.5 275
135
84.3
270 58.5
25 70.2
320
37
182
62
53
47.5
41
58.5
58
116
6-M12*3518
134.5
119
118
29
36
120.5
122.3
125.8
158
UNION ELECTRICS
Molded Case Circuit Breaker
www.unionele.com I 32
UNDM5DC-250
UNDM5DC-315
UNDM5DC-400
UNDM5DC-400V
UNDM5DC-630
UNDM5DC-630V
UNDM5DC-800
Hold Characteristics
The circuit breaker's thermal-actuated release has a unique inverse time-delay characteristic; the electromagnetic release is instantaneous in action, and its
characteristics are detailed in the table below
For power distribution
Rated Current (A)
Thermal release(ambient temperature +40℃)
Non-operation time at 1.05 times
rated current (cold state) in hours
Operation time at 1.3 times rated
current (hot state) in hours
Model Current when energized(A) Total Power Loss for Three-phase/Four-phase(W)
Power loss table
Outline Dimensions
UNDM-250、315(3P)
LINE
1 3 5
OFF
2 4 6
107
36
98.38046.3
408363.8 343.8
50.8 34.7
19.5
20.5 200167.5
26
42.5
23.5
PUSH TO TRIR
LOAD
38.5
35
51.5
6-M8*20
70
95
99
98
26
26
102
104
109
135.2
Phase barrier
UNDM-250、315(2P)
UNION ELECTRICS
Molded Case Circuit Breaker
31 I www.unionele.com
AC Distribution Protection
①Overload long-delay setting current (A)lr(Factory value: 1.0ln)
②Overload long delay setting time (S)Tr(Factory value :12)
③Short-circuit short-delay setting current (A)lsd(Factory value :OFF)
④Short-circuit short delay setting time (S)Tsd(Factory value :OFF)
⑤Short-circuitinstantaneous setting current (A)li(Factory value :12)
⑥Neutralline protection(default)(Factory value :OFF)
Grounding protection setting current (A)lg(Optional function)(Factory value :OFF)
UNION ELECTRICS
Molded Case Circuit Breaker
UNAE-250H UNAE-400H UNAE-630H
Adjustable range: (0.5~1.0) x ln
Fouradjustable Settings: 12、60、80、100
Adjustablerange: (1.5、2、3、4、5、6、7、8、9) x lr+OFF
Four adjustable Settings: 0.05、0.1、0.25、0.5
Adjustablerange: li=(2、3、4、6、8、9、10、11、12)xIn+OFF
Built-in fixation < 0.05
Adjustable range: (0.5、1.0) x lr+OFF
Adjustablerange: lg=(0.2、0.3、0.4、0.5、0.6、0.7、0.8、0.9、1)xIn+OFF
0.1
Overload protection
Overload long-delay setting current (A)lr
Overload long delay setting time (s)Tr
Short-circuit short-delay protection
Short-circuit short-delay setting current (A)lsd
Short-circuit short delay setting time (s)TSd
Short-circuit instantaneous protection
Short-circuit instantaneous setting current (A)li
Short-circuit instantaneous setting time (s)Ti
Neutral line protection
Protection current (A)
Grounding protection
Grounding protection setting current (A)lg
Grounding protection setting time (s)Tg
Electronic molded case circuit breaker
www.unionele.com I 34
Electronic MCCB
The UNAE series electronic molded case circuit breakers come in threeshell types that
can be matched with the basic type forAC distributionprotection, with a rated working
current ranging from 40A to 630A.
General
It features high tripping accuracy, reliable operation and is not affected by the external
environmental temperature;
Operating environment temperature:-40°C to +70°C.
UNION ELECTRICS
Molded Case Circuit Breaker
UNAE-250H UNAE-400H UNAE-630H
107*165*101
142*165*101
140*257*110
184*257*110
140*257*110
184*257*110
H
W L
W*L*H(mm)
33 I www.unionele.com
AC Distribution Protection
①Overload long-delay setting current (A)lr(Factory value: 1.0ln)
②Overload long delay setting time (S)Tr(Factory value :12)
③Short-circuit short-delay setting current (A)lsd(Factory value :OFF)
④Short-circuit short delay setting time (S)Tsd(Factory value :OFF)
⑤Short-circuitinstantaneous setting current (A)li(Factory value :12)
⑥Neutralline protection(default)(Factory value :OFF)
Grounding protection setting current (A)lg(Optional function)(Factory value :OFF)
UNION ELECTRICS
Molded Case Circuit Breaker
UNAE-250H UNAE-400H UNAE-630H
Adjustable range: (0.5~1.0) x ln
Fouradjustable Settings: 12、60、80、100
Adjustablerange: (1.5、2、3、4、5、6、7、8、9) x lr+OFF
Four adjustable Settings: 0.05、0.1、0.25、0.5
Adjustablerange: li=(2、3、4、6、8、9、10、11、12)xIn+OFF
Built-in fixation < 0.05
Adjustable range: (0.5、1.0) x lr+OFF
Adjustablerange: lg=(0.2、0.3、0.4、0.5、0.6、0.7、0.8、0.9、1)xIn+OFF
0.1
Overload protection
Overload long-delay setting current (A)lr
Overload long delay setting time (s)Tr
Short-circuit short-delay protection
Short-circuit short-delay setting current (A)lsd
Short-circuit short delay setting time (s)TSd
Short-circuit instantaneous protection
Short-circuit instantaneous setting current (A)li
Short-circuit instantaneous setting time (s)Ti
Neutral line protection
Protection current (A)
Grounding protection
Grounding protection setting current (A)lg
Grounding protection setting time (s)Tg
Electronic molded case circuit breaker
www.unionele.com I 34
Electronic MCCB
The UNAE series electronic molded case circuit breakers come in threeshell types that
can be matched with the basic type forAC distributionprotection, with a rated working
current ranging from 40A to 630A.
General
It features high tripping accuracy, reliable operation and is not affected by the external
environmental temperature;
Operating environment temperature:-40°C to +70°C.
UNION ELECTRICS
Molded Case Circuit Breaker
UNAE-250H UNAE-400H UNAE-630H
107*165*101
142*165*101
140*257*110
184*257*110
140*257*110
184*257*110
H
W L
W*L*H(mm)
33 I www.unionele.com
Environmental requirements for circuit breaker installation sites
Project
Ambient Air Temperature
Relative Humidity
Altitude
Pollution Level
Specification
-5°C~+40°C, with the 24h average value·not exceeding +35°C (at +40°C)
No more than 2000m
Level 3
Average relative humidity not exceeding 50%. In the wettest month, the average minimum
temperature should not exceed +25°C, and the average maximum relative humidity in that
month should not exceed 90%, taking into account possible condensation on the product
surface due to temperature changes.
Adjustment knob
UNM6E MCCB
UNION ELECTRICS
Molded Case Circuit Breaker
www.unionele.com I 36
H
W L
W*L*H(mm)
Rated limit short circuit breaking capacity lcu(kA )
Rated short-circuitbreaking capacity lcs(kA)
Rated short-time withstand current lcw (kA)/1s
Operation life(cycle)
Arcing distance (mm)
UNAE-1250
210*400*132
280*400*132
1250
1000 1250 1600
AC400V
AC1000V
AC 12kV
65
50
10kA/0.5s
NO 500 / OFF 2500
≤120
Rated operational voltage (Ue): AC 400 V / 690 V
Rated insulation voltage (Ui): 1000 V
Rated impulse withstand voltage (Uimp): 8000 V
Circuit Breaker Voltage Ratings
Outline Dimensions
UNAE-250
UNAE-400/630
UNION ELECTRICS
Molded Case Circuit Breaker
35 I www.unionele.com
Environmental requirements for circuit breaker installation sites
Project
Ambient Air Temperature
Relative Humidity
Altitude
Pollution Level
Specification
-5°C~+40°C, with the 24h average value·not exceeding +35°C (at +40°C)
No more than 2000m
Level 3
Average relative humidity not exceeding 50%. In the wettest month, the average minimum
temperature should not exceed +25°C, and the average maximum relative humidity in that
month should not exceed 90%, taking into account possible condensation on the product
surface due to temperature changes.
Adjustment knob
UNM6E MCCB
UNION ELECTRICS
Molded Case Circuit Breaker
www.unionele.com I 36
H
W L
W*L*H(mm)
Rated limit short circuit breaking capacity lcu(kA )
Rated short-circuitbreaking capacity lcs(kA)
Rated short-time withstand current lcw (kA)/1s
Operation life(cycle)
Arcing distance (mm)
UNAE-1250
210*400*132
280*400*132
1250
1000 1250 1600
AC400V
AC1000V
AC 12kV
65
50
10kA/0.5s
NO 500 / OFF 2500
≤120
Rated operational voltage (Ue): AC 400 V / 690 V
Rated insulation voltage (Ui): 1000 V
Rated impulse withstand voltage (Uimp): 8000 V
Circuit Breaker Voltage Ratings
Outline Dimensions
UNAE-250
UNAE-400/630
UNION ELECTRICS
Molded Case Circuit Breaker
35 I www.unionele.com
Contactor
More auxiliary contacts, meet various application requirements.
Suitable for larger voltage fluctuation to ensure the stable operation of the equipment.
Super environment adaptability, can be reliable operation with extreme environment.
Product Overview
Specifications
Rated operational current (Ie): 9-225 A
Rated operational voltage (Ue): 220-690 V
Rated insulation voltage: 690 V
Poles: 3P,4P
Installation: DIN rail and screw mounting
The UNAC and UNC1 series AC Contactors – UNAC-09, UNAC-12, UNAC-18, UNAC-25, UNAC-32, UNAC-40, UNAC-50, UNAC-65, UNAC80, UNAC-95, UNC1-115, UNC1-150, UNC1-180, UNC1-225 feature a modern design and compact structure. They are suitable for
starting and controlling AC motors, frequent switching, and remote circuit control.
When combined with a thermal relay, these contactors can be used to assemble a magnetic motor starter.
Standards: IEC 60947-1, IEC 60947-4-1
UNION ELECTRICS
AC Contactor
www.unionele.com I 38
Model Overall dimensions Installation dimensions Pole
UNM6E-1250
Outline Dimensions
Usage Environment
The circuit breaker must not be installed in the following environments:
Locations containing explosive gases (risk of explosion).
Extremely humid areas.
Sites where the external magnetic field exceeds 5 times the Earth’s magnetic field, as this may cause malfunction.
Locations subject to vibrations greater than 5 g.
Areas containing corrosive gases or vapors that could damage metal parts or insulation.
UNION ELECTRICS
Molded Case Circuit Breaker
37 I www.unionele.com
Insulation Test
Test instrument: Use a 1000 V DC megohmmeter.
Test conditions: With the circuit breaker in the open position, perform insulation resistance measurements as follows:
1.Between inlet and outlet connection terminals: 1–2, 3–4, and 5–6
2.Between terminals 1, 3, and 5 (connected by wires) and the circuit breaker casing (casing covered with metal foil)
3.Between the undervoltage release of the main circuit and the circuit breaker casing
Insulation resistance requirement: Not less than 20 MΩ.
Alternative test method: If a 1000 V DC megohmmeter is not available, a powerfrequency withstand voltage tester may be used.
Apply 3000 V AC for 1 minute across the same test points specified above.
Each circuit breaker is factory-tested for insulation in compliance with applicable standards.
However, if re-testing is required before installation, the following procedure must be observed:
Contactor
More auxiliary contacts, meet various application requirements.
Suitable for larger voltage fluctuation to ensure the stable operation of the equipment.
Super environment adaptability, can be reliable operation with extreme environment.
Product Overview
Specifications
Rated operational current (Ie): 9-225 A
Rated operational voltage (Ue): 220-690 V
Rated insulation voltage: 690 V
Poles: 3P,4P
Installation: DIN rail and screw mounting
The UNAC and UNC1 series AC Contactors – UNAC-09, UNAC-12, UNAC-18, UNAC-25, UNAC-32, UNAC-40, UNAC-50, UNAC-65, UNAC80, UNAC-95, UNC1-115, UNC1-150, UNC1-180, UNC1-225 feature a modern design and compact structure. They are suitable for
starting and controlling AC motors, frequent switching, and remote circuit control.
When combined with a thermal relay, these contactors can be used to assemble a magnetic motor starter.
Standards: IEC 60947-1, IEC 60947-4-1
UNION ELECTRICS
AC Contactor
www.unionele.com I 38
Model
Overall dimensions Installation dimensions
Pole
UNM6E-1250
Outline Dimensions
Usage Environment
The circuit breaker must not be installed in the following environments:
Locations containing explosive gases (risk of explosion).
Extremely humid areas.
Sites where the external magnetic field exceeds 5 times the Earth’s magnetic field, as this may cause malfunction.
Locations subject to vibrations greater than 5 g.
Areas containing corrosive gases or vapors that could damage metal parts or insulation.
UNION ELECTRICS
Molded Case Circuit Breaker
37 I www.unionele.com
Insulation Test
Test instrument: Use a 1000 V DC megohmmeter.
Test conditions: With the circuit breaker in the open position, perform insulation resistance measurements as follows:
1.Between inlet and outlet connection terminals: 1–2, 3–4, and 5–6
2.Between terminals 1, 3, and 5 (connected by wires) and the circuit breaker casing (casing covered with metal foil)
3.Between the undervoltage release of the main circuit and the circuit breaker casing
Insulation resistance requirement: Not less than 20 MΩ.
Alternative test method: If a 1000 V DC megohmmeter is not available, a powerfrequency withstand voltage tester may be used.
Apply 3000 V AC for 1 minute across the same test points specified above.
Each circuit breaker is factory-tested for insulation in compliance with applicable standards.
However, if re-testing is required before installation, the following procedure must be observed:
Technical Data
Operating and Installation Conditions
III
3
CE, CB, TUV
UNAC-09~40 do IP20; UNAC-50~95 do IP10
limit of temperature: -35℃~+70℃,normal temperature: -5℃~+40℃,
The average no more than +35℃ within 24 hours.
If not in normal operating temperature range, please refer to \"Instructions for abnormal environment\"
≤2000m
The maximum temperature of 70 degrees, the air relative humidity not exceed 50%, under lower temperature can
allow for higher relative humidity.
If the temperature is 20℃, the air relative humidity could up to 90%, Special measures should be taken for occasional
condensation due to humidity changes.
Inclination between installation surface and vertical surface should not exceed ±5°
Products should be installed and used without significant shake, shock and vibration place.
Type
Installation category
Pollution level
Certification
Protection degree
Ambient temperature
Altitude
Ambient temperature
Installation position
Shock vibration
Overall And Mounting
UNAC-50~95 3P
UNAC-09~40 3P
c
d
e
f
5.5
3575
4.5
b
Bmax Cmax a
Amax
Amax
Bmax Cmax
4-Φ9
Type Amax Bmax Cmax a b c d e f
UNAC-09, 12, 18(3P)
UNAC-25, 32, 40(3P)
UNAC-50, 65(3P)
UNAC-80, 95(3P)
74.5
83
127.5
127.5
45.5
56.5
74.5
85.5
85.5
97
117
125.5
35
40
-
-
50/60
50/70
-
-
-
-
105
105
-
-
40
40
-
-
100/110
100/110
-
-
59
67
UNION ELECTRICS
AC Contactor
www.unionele.com I 40
Auxiliary contacts
AC
DC
AC-15
DC-13
Connecting capability of main circuit terminal
Coil
Specifications
UNAC-09 UNAC-12 UNAC-18 UNAC-25 UNAC-32 UNAC-40 UNAC-50 UNAC-65 UNAC-80 UNAC-95
Main circuit characteristic
Poles
Rated
operation
current(Ie)
Rated
operational
power(Pe)
Rated insulation voltage(Ui)
Mechanical life
Electrical life
Rated control
voltage(Us)
Rated operating
voltage (Ue)
Allowed control
circuit voltage(Us)
Frequency
of operation
AC-3,380/400V
AC-3,660/690V
AC-4,380/400V
AC-4,660/690V
AC-3,380/400V
AC-3,660/690V
AC-4,380/400V
AC-4,660/690V
AC-3
AC-4
AC-3
AC-4
1 wire
2 wire
1 wire
2 wire
1 wire
2 wire
N·m
V
V
A
A
A
A
kW
kW
kW
kW
10000
times
times/
hour
mm²
mm²
mm²
mm²
mm²
mm²
V
V
V
V
VA
VA
W
A
A
V
V
VA
W
Flexible wire
No terminal
Flexible wire
With terminals
Hard wire
No terminal
Fastening torque
50Hz
50/60Hz
Operation
Release
Actuation
Keep
Consumption
Rated thermal current(Ith),AC-1
Rated operating voltage(Ue)
Power
consumption
of coil
Auxiliary contacts specification
Rated thermal current (Ith)
Rated control
capacit
Certification
3P/4P
690
380/400, 660/690
20
9
6.6
3.5
1.5
4
5.5
1.5
1.1
20
12
8.9
5
2
5.5
7.5
2.2
1.5
32
18
12
7.7
3.8
7.5
10
3.3
3
40
25
18
8.5
4.4
11
15
4
3.7
50
32
22
12
7.5
15
18.5
5.4
5.5
50
38
22
14
8.9
18.5
18.5
5.5
6
80
50
39
24
12
22
33
11
10
80
65
42
28
14
30
37
15
11
125
80
49
37
17.3
37
45
18.5
15
125
95
49
44
21.3
45
45
22
18.5
1200
110
22
1200
300
1…4
1…4
1…4
1…2.5
1…4
1…4
1.2
60
6-9.5
1-3
AC 24、36、48、110、127、220/230、240、380/400、415、440
AC 24、36、48、110、127、220/230、240、380/400、415、440
Installation inclination angle ±22.5°: 85%~110%Us;Installation inclination angle±5°: 70%~120%
Installation inclination angle ±22.5°: 20%~75%Us;Installation inclination angle±5°: 20%~65%
1000
90
22
900 650
65
17 11
600
300
1.5…6
1.5…6
1…6
1…4
1.5…
1.8
70
6-9.5
1-3
11
10
380
220
360
33
CE, TUV, CB
1.5…6 1.5…10
2.5…25
2.5…16
2.5…25
2.5…10
2.5…25
2.5…10
5
200
15-20
6-10
4…50
4…25
4…50
4…16
4…50
4…25
9
200
15-20
6-10
Type
Appearance
UNACSpecifications
UNAC-09
UNAC-25
UNAC-65
UNAC-95
UNION ELECTRICS
AC Contactor
39 I www.unionele.com
Technical Data
Operating and Installation Conditions
III
3
CE, CB, TUV
UNAC-09~40 do IP20; UNAC-50~95 do IP10
limit of temperature: -35℃~+70℃,normal temperature: -5℃~+40℃,
The average no more than +35℃ within 24 hours.
If not in normal operating temperature range, please refer to \"Instructions for abnormal environment\"
≤2000m
The maximum temperature of 70 degrees, the air relative humidity not exceed 50%, under lower temperature can
allow for higher relative humidity.
If the temperature is 20℃, the air relative humidity could up to 90%, Special measures should be taken for occasional
condensation due to humidity changes.
Inclination between installation surface and vertical surface should not exceed ±5°
Products should be installed and used without significant shake, shock and vibration place.
Type
Installation category
Pollution level
Certification
Protection degree
Ambient temperature
Altitude
Ambient temperature
Installation position
Shock vibration
Overall And Mounting
UNAC-50~95 3P
UNAC-09~40 3P
c
d
e
f
5.5
3575
4.5
b
Bmax Cmax a
Amax
Amax
Bmax Cmax
4-Φ9
Type Amax Bmax Cmax a b c d e f
UNAC-09, 12, 18(3P)
UNAC-25, 32, 40(3P)
UNAC-50, 65(3P)
UNAC-80, 95(3P)
74.5
83
127.5
127.5
45.5
56.5
74.5
85.5
85.5
97
117
125.5
35
40
-
-
50/60
50/70
-
-
-
-
105
105
-
-
40
40
-
-
100/110
100/110
-
-
59
67
UNION ELECTRICS
AC Contactor
www.unionele.com I 40
Auxiliary contacts
AC
DC
AC-15
DC-13
Connecting capability of main circuit terminal
Coil
Specifications
UNAC-09 UNAC-12 UNAC-18 UNAC-25 UNAC-32 UNAC-40 UNAC-50 UNAC-65 UNAC-80 UNAC-95
Main circuit characteristic
Poles
Rated
operation
current(Ie)
Rated
operational
power(Pe)
Rated insulation voltage(Ui)
Mechanical life
Electrical life
Rated control
voltage(Us)
Rated operating
voltage (Ue)
Allowed control
circuit voltage(Us)
Frequency
of operation
AC-3,380/400V
AC-3,660/690V
AC-4,380/400V
AC-4,660/690V
AC-3,380/400V
AC-3,660/690V
AC-4,380/400V
AC-4,660/690V
AC-3
AC-4
AC-3
AC-4
1 wire
2 wire
1 wire
2 wire
1 wire
2 wire
N·m
V
V
A
A
A
A
kW
kW
kW
kW
10000
times
times/
hour
mm²
mm²
mm²
mm²
mm²
mm²
V
V
V
V
VA
VA
W
A
A
V
V
VA
W
Flexible wire
No terminal
Flexible wire
With terminals
Hard wire
No terminal
Fastening torque
50Hz
50/60Hz
Operation
Release
Actuation
Keep
Consumption
Rated thermal current(Ith),AC-1
Rated operating voltage(Ue)
Power
consumption
of coil
Auxiliary contacts specification
Rated thermal current (Ith)
Rated control
capacit
Certification
3P/4P
690
380/400, 660/690
20
9
6.6
3.5
1.5
4
5.5
1.5
1.1
20
12
8.9
5
2
5.5
7.5
2.2
1.5
32
18
12
7.7
3.8
7.5
10
3.3
3
40
25
18
8.5
4.4
11
15
4
3.7
50
32
22
12
7.5
15
18.5
5.4
5.5
50
38
22
14
8.9
18.5
18.5
5.5
6
80
50
39
24
12
22
33
11
10
80
65
42
28
14
30
37
15
11
125
80
49
37
17.3
37
45
18.5
15
125
95
49
44
21.3
45
45
22
18.5
1200
110
22
1200
300
1…4
1…4
1…4
1…2.5
1…4
1…4
1.2
60
6-9.5
1-3
AC 24、36、48、110、127、220/230、240、380/400、415、440
AC 24、36、48、110、127、220/230、240、380/400、415、440
Installation inclination angle ±22.5°: 85%~110%Us;Installation inclination angle±5°: 70%~120%
Installation inclination angle ±22.5°: 20%~75%Us;Installation inclination angle±5°: 20%~65%
1000
90
22
900 650
65
17 11
600
300
1.5…6
1.5…6
1…6
1…4
1.5…
1.8
70
6-9.5
1-3
11
10
380
220
360
33
CE, TUV, CB
1.5…6 1.5…10
2.5…25
2.5…16
2.5…25
2.5…10
2.5…25
2.5…10
5
200
15-20
6-10
4…50
4…25
4…50
4…16
4…50
4…25
9
200
15-20
6-10
Type
Appearance
UNACSpecifications
UNAC-09
UNAC-25
UNAC-65
UNAC-95
UNION ELECTRICS
AC Contactor
39 I www.unionele.com
Specifications
Appearance
UNACSpecifications
115
150
185
225
30
40
55
63
75
100
110
147
200
220
250
55
75
90
110
132
160
200
250
335
400
450
59
80
100
110
140
180
220
280
375
425
450
59
80
100
110
140
180
220
280
375
425
450
75
90
110
130
160
220
257
355
400
450
450
80
100
110
129
160
220
280
335
450
475
470
62
62
100
100
147
160
185
335
450
450
450
1200
1200
600
600
600
600
600
600
600
600
600
120
120
100
100
80
80
80
80
80
80
80
1000
1000
600
600
600
600
600
600
600
600
600
Mech anical
4
life*10
Electrical life
4 AC-3*10
Operating
frequency
(time/hour)AC-3 220V
230V
380V
400V 415V 400V 500V 660V
690V 1000V
Type Rated operational
currentin AC-3(A)
Max power ratings of 3-phase motors incategory AC-3(kW)
UNAC-F265
UNAC-F330
201.5
244.5
213
261
203
203
206
206
145
145
145
145
375
375
375
375
213
213
213
213
147
147
147
147
142
190
154.5
202.5
96
96
96
96
106
106
106
106
120
120
120
120
141
141
145
145
178
178
181
181
48
48
48
48
39
34
43
43
66.5
66.5
74
74
25
25
25
25
44.5
44.5
44.5
44.5
38
38
38
38
21.5
21.5
20.5
20.5
3P
4P
3P
4P
UNAC-F115
UNAC-F150
UNAC-F185
UNAC-F225
163.5
200.5
163.5
200.5
168.5
208.5
168.5
208.5
162
162
170
170
174
174
197
197
137
137
137
137
137
137
137
137
265
265
301
301
305
305
364
364
171
171
171
171
181
181
181
181
131
131
131
131
130
130
130
130
106
143
106
143
111
151
111
151
80
80
80
80
80
80
80
80
106
106
106
106
106
106
106
106
120
120
120
120
120
120
120
120
107
107
107
107
113.5
113.5
113.5
113.5
147
147
150
150
154
154
172
172
37
37
40
40
40
40
48
48
29.5
29.5
26
26
29
29
21
17
60
60
57.5
55.5
59.5
59.5
51.5
47.5
20
20
20
20
20
20
25
25
26
26
34
34
34
34
44.5
44.5
44
44
44
44
44
44
44
44
13.5
13.5
13.5
13.5
13.5
13.5
13.5
13.5
a b b1 b2 c f G G1 J J1 L M P Q Q1 S 1 Y Z
3P
4P
3P
4P
3P
4P
3P
4P
Type
UNION ELECTRICS
AC Contactor
265
330
400
500
630
780
800
UNAC-F115
UNAC-F150
UNAC-F185
UNAC-F225
UNAC-F265
UNAC-F330
UNAC-F400
UNAC-F500
UNAC-F630
UNAC-F780
UNAC-F800
Overall And Mounting
UNAC-F115~F330
UNAC-F115
UNAC-F225
www.unionele.com I 42
UNION ELECTRICS
AC Contactor
UNAC-50~95 4P
UNAC-09~40 4P
Picture
AC-3 Ac Contactor Auxiliary Blocks (1NO + 1NC)
AC-3 Ac Contactor Side Auxillary Blocks (2NO + 2NC)
AC Contactor Auxiliary Blocks
Description
Picture
3P
3P
3P
3P
3P
3P
3P
3P
18A 7.5KVAR
25A 12KVAR
32A 18KVAR
43A 20KVAR
50A 25KVAR
65A 30KVAR
80A 40KVAR
95A 50KVAR
Description
AC Contactors For Capacitor Banks
Picture Poles
Type
UNAC-09, 12, 18(4P)
UNAC-25, 32, 38, 40(4P)
UNAC-50, 65(4P)
UNAC-80, 95(4P)
41 I www.unionele.com
Specifications
Appearance
UNACSpecifications
115
150
185
225
30
40
55
63
75
100
110
147
200
220
250
55
75
90
110
132
160
200
250
335
400
450
59
80
100
110
140
180
220
280
375
425
450
59
80
100
110
140
180
220
280
375
425
450
75
90
110
130
160
220
257
355
400
450
450
80
100
110
129
160
220
280
335
450
475
470
62
62
100
100
147
160
185
335
450
450
450
1200
1200
600
600
600
600
600
600
600
600
600
120
120
100
100
80
80
80
80
80
80
80
1000
1000
600
600
600
600
600
600
600
600
600
Mech anical
4
life*10
Electrical life
4 AC-3*10
Operating
frequency
(time/hour)AC-3 220V
230V
380V
400V 415V 400V 500V 660V
690V 1000V
Type Rated operational
currentin AC-3(A)
Max power ratings of 3-phase motors incategory AC-3(kW)
UNAC-F265
UNAC-F330
201.5
244.5
213
261
203
203
206
206
145
145
145
145
375
375
375
375
213
213
213
213
147
147
147
147
142
190
154.5
202.5
96
96
96
96
106
106
106
106
120
120
120
120
141
141
145
145
178
178
181
181
48
48
48
48
39
34
43
43
66.5
66.5
74
74
25
25
25
25
44.5
44.5
44.5
44.5
38
38
38
38
21.5
21.5
20.5
20.5
3P
4P
3P
4P
UNAC-F115
UNAC-F150
UNAC-F185
UNAC-F225
163.5
200.5
163.5
200.5
168.5
208.5
168.5
208.5
162
162
170
170
174
174
197
197
137
137
137
137
137
137
137
137
265
265
301
301
305
305
364
364
171
171
171
171
181
181
181
181
131
131
131
131
130
130
130
130
106
143
106
143
111
151
111
151
80
80
80
80
80
80
80
80
106
106
106
106
106
106
106
106
120
120
120
120
120
120
120
120
107
107
107
107
113.5
113.5
113.5
113.5
147
147
150
150
154
154
172
172
37
37
40
40
40
40
48
48
29.5
29.5
26
26
29
29
21
17
60
60
57.5
55.5
59.5
59.5
51.5
47.5
20
20
20
20
20
20
25
25
26
26
34
34
34
34
44.5
44.5
44
44
44
44
44
44
44
44
13.5
13.5
13.5
13.5
13.5
13.5
13.5
13.5
a b b1 b2 c f G G1 J J1 L M P Q Q1 S 1 Y Z
3P
4P
3P
4P
3P
4P
3P
4P
Type
UNION ELECTRICS
AC Contactor
265
330
400
500
630
780
800
UNAC-F115
UNAC-F150
UNAC-F185
UNAC-F225
UNAC-F265
UNAC-F330
UNAC-F400
UNAC-F500
UNAC-F630
UNAC-F780
UNAC-F800
Overall And Mounting
UNAC-F115~F330
UNAC-F115
UNAC-F225
www.unionele.com I 42
UNION ELECTRICS
AC Contactor
UNAC-50~95 4P
UNAC-09~40 4P
Picture
AC-3 Ac Contactor Auxiliary Blocks (1NO + 1NC)
AC-3 Ac Contactor Side Auxillary Blocks (2NO + 2NC)
AC Contactor Auxiliary Blocks
Description
Picture
3P
3P
3P
3P
3P
3P
3P
3P
18A 7.5KVAR
25A 12KVAR
32A 18KVAR
43A 20KVAR
50A 25KVAR
65A 30KVAR
80A 40KVAR
95A 50KVAR
Description
AC Contactors For Capacitor Banks
Picture Poles
Type
UNAC-09, 12, 18(4P)
UNAC-25, 32, 38, 40(4P)
UNAC-50, 65(4P)
UNAC-80, 95(4P)
41 I www.unionele.com
The UNAC-M series AC Contactor features a modern design and compact structure, making it suitable for frequent starting and stopping
of AC motors, as well as remote switching of circuits over long distances. When combined with a thermal overload relay, it forms a
complete magnetic motor starter system.
Standards: IEC 60947-1, IEC 60947-4-1
UNAC-M □□ □□ - /□
Model and Meaning
Z = DC operation, N = Reversible AC contactor
Contact types and quantities are indicated by numbers (reversible contactors refer to the contact
configuration of a single unit):
10 → Three normally open (NO) main contacts + one NO auxiliary contact
01 → Three NO main contacts + one normally closed (NC) auxiliary contact
08 → Two NO main contacts + two NC main contacts
40 → Four NO main contacts
Rated current: Expressed as the rated operational current under AC-3 utilization category at 400V (380V)
(6A, 9A, 12A, 16A)
Design serial number
Product Overview
Mini
Contactor
Specifications
Rated operational current (Ie): 6–16 A
Rated operational voltage (Ue): 220–690 V
Rated insulation voltage (Ui): 690 V
Poles: 3P / 4P
Mounting: DIN rail and screw installation
Application: Motor starting, stopping, and remote control of AC circuits
www.unionele.com I 44
UNION ELECTRICS
AC Contactor
43 I www.unionele.com
UNION ELECTRICS
AC Contactor
UNAC-F400
UNAC-F500
213
213
213
233
233
233
206
206
206
238
238
238
375
375
375
400
400
400
219
219
219
232
232
232
119
119
119
141
141
141
80
80
80
80
80
140
66
66
66
66
66
66
170
170
170
170
170
230
156
156
156
156
156
156
192
192
240
210
210
265
19.5
19.5
67.5
39.5
39.5
34.5
145
145
145
145
146
146
181
181
181
208
208
208
48
48
48
55
55
55
69
43
43
76
46
46
96
74
74
102
77
77
25
25
25
30
30
30
a b b2 c f G* G min G1* G1 min G1 max J L M P Q Q1 S
2P
3P
4P
2P
3P
4P
Type
102
102
150
120
120
175
G max
UNAC-F630
UNAC-F630,F800
UNAC-F630
309
309
389
180
180
240
100
100
150
195
195
275
68.5
68.5
68.5
102
60
60
127
89
89
a G G min J1 Q Q1
2P
3P
4P
Type G max
UNAC-F400~F500
UNAC-F630~F800
The UNAC-M series AC Contactor features a modern design and compact structure, making it suitable for frequent starting and stopping
of AC motors, as well as remote switching of circuits over long distances. When combined with a thermal overload relay, it forms a
complete magnetic motor starter system.
Standards: IEC 60947-1, IEC 60947-4-1
UNAC-M □□ □□ - /□
Model and Meaning
Z = DC operation, N = Reversible AC contactor
Contact types and quantities are indicated by numbers (reversible contactors refer to the contact
configuration of a single unit):
10 → Three normally open (NO) main contacts + one NO auxiliary contact
01 → Three NO main contacts + one normally closed (NC) auxiliary contact
08 → Two NO main contacts + two NC main contacts
40 → Four NO main contacts
Rated current: Expressed as the rated operational current under AC-3 utilization category at 400V (380V)
(6A, 9A, 12A, 16A)
Design serial number
Product Overview
Mini
Contactor
Specifications
Rated operational current (Ie): 6–16 A
Rated operational voltage (Ue): 220–690 V
Rated insulation voltage (Ui): 690 V
Poles: 3P / 4P
Mounting: DIN rail and screw installation
Application: Motor starting, stopping, and remote control of AC circuits
www.unionele.com I 44
UNION ELECTRICS
AC Contactor
43 I www.unionele.com
UNION ELECTRICS
AC Contactor
UNAC-F400
UNAC-F500
213
213
213
233
233
233
206
206
206
238
238
238
375
375
375
400
400
400
219
219
219
232
232
232
119
119
119
141
141
141
80
80
80
80
80
140
66
66
66
66
66
66
170
170
170
170
170
230
156
156
156
156
156
156
192
192
240
210
210
265
19.5
19.5
67.5
39.5
39.5
34.5
145
145
145
145
146
146
181
181
181
208
208
208
48
48
48
55
55
55
69
43
43
76
46
46
96
74
74
102
77
77
25
25
25
30
30
30
a b b2 c f G* G min G1* G1 min G1 max J L M P Q Q1 S
2P
3P
4P
2P
3P
4P
Type
102
102
150
120
120
175
G max
UNAC-F630
UNAC-F630,F800
UNAC-F630
309
309
389
180
180
240
100
100
150
195
195
275
68.5
68.5
68.5
102
60
60
127
89
89
a G G min J1 Q Q1
2P
3P
4P
Type G max
UNAC-F400~F500
UNAC-F630~F800
Operating and Installation Conditions
Type Operating and Installation Conditions
Installation category
Pollution level
Certification
Protection degree
III
3
CE, CB, TUV
Ip20
Ambient temperature
limit of temperature: -35℃~+70℃,
normal temperature: -5℃~+40℃,
The average no more than +35℃ within 24 hours.
If not in normal operating temperature range, please
refer to \"Instructions for abnormal environment\"
Altitude ≤2000m
Ambient temperature
The maximum temperature of 70 degrees, the air
relative humidity not exceed 50%, under lower
temperature can allow for higher relative humidity.
If the temperature is 20℃, the air relative humidity
could up to 90%, Special measures should be taken
for occasional condensation due to humidity changes.
Installation position
Shock vibration
Inclination between installation surface and vertical
surface should not exceed ±5°
Products should be installed and used without
significant shake, shock and vibration place.
Overall and Mounting
Type Amax
UNAC-M06-M16
Bmax Cmax a b
45.5
Installation and overall dimensions of UNAC-M06~M16 series AC contactor
Dmax Φ
59 58 94 35±0.35 50±0.48 4.2
UNAC-M06/Z-M16/Z 45.5 59 70 106 35±0.35 50±0.48 4.2
www.unionele.com I 46
b Bmax
Cmax
Dmax(F4-M)
a
Amax
UNION ELECTRICS
AC Contactor
Auxiliary contacts
AC
DC
AC-15
DC-13
Connecting capability of main circuit terminal
Coil
Specifications
Specifications
Main circuit characteristic
Poles
Rated
operation
current(Ie)
power(Pe)
Rated insulation voltage(Ui)
Mechanical life
Electrical life
Rated operating
voltage (Ue)
Frequency
of operation
AC-3,380/400V
AC-3,660/690V
AC-4,380/400V
AC-4,660/690V
AC-3,380/400V
AC-3,660/690V
AC-3
AC-4
AC-3
AC-4
1 wire
2 wire
1 wire
2 wire
1 wire
2 wire
N·m
V
V
A
A
A
A
kW
kW
10000
times
times/
hour
mm²
mm²
mm²
mm²
mm²
mm²
V
V
V
V
VA
VA
W
A
A
V
V
VA
W
Flexible wire
No terminal
Flexible wire
With terminals
Hard wire
No terminal
Fastening torque
50Hz
50/60Hz
Operation
Release(AC)
Actuation
Keep
Consumption
Rated thermal current(Ith),AC-1
Rated operating voltage(Ue)
Auxiliary contacts specification
Rated thermal current (Ith)
Rated control
capacit
Certification
3P/4P
690
380/400, 660/690
1200
120
See electrical life curve
1200
300
24、36、48、110、127、220、380、415
24、36、48、110、127、220、380、415
Installation inclination angle ±22.5°: 85%~110%Us; Installation inclination angle±5°: 70%~120%
Installation inclination angle ±22.5°: 20%~75%Us;Installation inclination angle±5°: 20%~60%
1NO/1NC
10
380/400
220
Ue/Ie: AC380V/400V/1.5A Ith: 10A
Ue/Ie: DC220V/0.3A
CE, TUV, CB
Type
Appearance
Rated operational
Power consumption
of coil
Allowed control
circuit voltage(Us)
Rated control
voltage(Us)
20-40
9.5
1-3
1
1…4
1…4
1…2.5
1…4
1…4
1.2
…4
UNAC-M06 UNAC-M09 UNAC-M12 UNAC-M16
20
6 9 12 16
3.8 4.9 4.9 4.9
6 9 9 12
A 3.8 4.9 4.9 4.9
2.2 4 5.5 7.5
3 4 4 4
DC V 12、24、36、48、110、127、220
Release(DC) V Installation inclination angle ±22.5°: 10%~75%Us;Installation inclination angle±5°: 10%~60%
45 I www.unionele.com
UNION ELECTRICS
AC Contactor
Operating and Installation Conditions
Type Operating and Installation Conditions
Installation category
Pollution level
Certification
Protection degree
III
3
CE, CB, TUV
Ip20
Ambient temperature
limit of temperature: -35℃~+70℃,
normal temperature: -5℃~+40℃,
The average no more than +35℃ within 24 hours.
If not in normal operating temperature range, please
refer to \"Instructions for abnormal environment\"
Altitude ≤2000m
Ambient temperature
The maximum temperature of 70 degrees, the air
relative humidity not exceed 50%, under lower
temperature can allow for higher relative humidity.
If the temperature is 20℃, the air relative humidity
could up to 90%, Special measures should be taken
for occasional condensation due to humidity changes.
Installation position
Shock vibration
Inclination between installation surface and vertical
surface should not exceed ±5°
Products should be installed and used without
significant shake, shock and vibration place.
Overall and Mounting
Type Amax
UNAC-M06-M16
Bmax Cmax a b
45.5
Installation and overall dimensions of UNAC-M06~M16 series AC contactor
Dmax Φ
59 58 94 35±0.35 50±0.48 4.2
UNAC-M06/Z-M16/Z 45.5 59 70 106 35±0.35 50±0.48 4.2
www.unionele.com I 46
b Bmax
Cmax
Dmax(F4-M)
a
Amax
UNION ELECTRICS
AC Contactor
Auxiliary contacts
AC
DC
AC-15
DC-13
Connecting capability of main circuit terminal
Coil
Specifications
Specifications
Main circuit characteristic
Poles
Rated
operation
current(Ie)
power(Pe)
Rated insulation voltage(Ui)
Mechanical life
Electrical life
Rated operating
voltage (Ue)
Frequency
of operation
AC-3,380/400V
AC-3,660/690V
AC-4,380/400V
AC-4,660/690V
AC-3,380/400V
AC-3,660/690V
AC-3
AC-4
AC-3
AC-4
1 wire
2 wire
1 wire
2 wire
1 wire
2 wire
N·m
V
V
A
A
A
A
kW
kW
10000
times
times/
hour
mm²
mm²
mm²
mm²
mm²
mm²
V
V
V
V
VA
VA
W
A
A
V
V
VA
W
Flexible wire
No terminal
Flexible wire
With terminals
Hard wire
No terminal
Fastening torque
50Hz
50/60Hz
Operation
Release(AC)
Actuation
Keep
Consumption
Rated thermal current(Ith),AC-1
Rated operating voltage(Ue)
Auxiliary contacts specification
Rated thermal current (Ith)
Rated control
capacit
Certification
3P/4P
690
380/400, 660/690
1200
120
See electrical life curve
1200
300
24、36、48、110、127、220、380、415
24、36、48、110、127、220、380、415
Installation inclination angle ±22.5°: 85%~110%Us; Installation inclination angle±5°: 70%~120%
Installation inclination angle ±22.5°: 20%~75%Us;Installation inclination angle±5°: 20%~60%
1NO/1NC
10
380/400
220
Ue/Ie: AC380V/400V/1.5A Ith: 10A
Ue/Ie: DC220V/0.3A
CE, TUV, CB
Type
Appearance
Rated operational
Power consumption
of coil
Allowed control
circuit voltage(Us)
Rated control
voltage(Us)
20-40
9.5
1-3
1
1…4
1…4
1…2.5
1…4
1…4
1.2
…4
UNAC-M06 UNAC-M09 UNAC-M12 UNAC-M16
20
6 9 12 16
3.8 4.9 4.9 4.9
6 9 9 12
A 3.8 4.9 4.9 4.9
2.2 4 5.5 7.5
3 4 4 4
DC V 12、24、36、48、110、127、220
Release(DC) V Installation inclination angle ±22.5°: 10%~75%Us;Installation inclination angle±5°: 10%~60%
45 I www.unionele.com
UNION ELECTRICS
AC Contactor
Derived Products When The Contactor is Assembled With Following Accessory Module
Derived products Contactor Accessorial modular Picture
Reversing
contactor
Auxiliary Contact
Dust cover
Electromagnetic
Starter
AC(V) 50Hz
AC(V) 60Hz
AC(V) 50/60Hz
DC(V)
24 36 48 110 127 220 380 415
24 36 48 110 127 220 380 415
24 36 48 110 127 220 380 415
12 24 36 48 110 127 220 -
UNAC-M
Rated impulse withstand voltage correction factor
Altitude (m)
Rated operation current correction factor
2000
1
3000
0.88
4000
0.78
1 0.92 0.90
Ambient temperature (℃) 55 60 65 70
Correction factor 1 0.93 0.875 0.75
www.unionele.com I 48
UNION ELECTRICS
AC Contactor
Type Amax Bmax Cmax a b
91
Installation and overall dimensions of UNAC-M06/N~M16/N series AC contactor
Dmax Φ
59 58 94 80±0.35 50±0.48 4.2
91 59 70 106 35±0.35 50±0.48 4.2
UNAC-M06/N-M16/N
UNAC-M06/Z/N-M16/Z/N
Type
Number of N/O contact
Configuration of contacts
F4-M Auxiliary contact group
Number of N/C contact
F4-M20
F4-M11
F4-M02
2
1
0
4
3
2
1
0
0
1
2
0
1
2
3
4
Product
F4
F4-M31
F4-M22
F4-M13
F4-M04
-M40
FS-M Surge suppression module
FS-M
Product
Model of Surge
Suppression Module Control Voltage
AC/DC:24V-48V
AC/DC:380V-440V
AC/DC:110V-240V
47 I www.unionele.com
a
Amax
b Bmax
Cmax
Dmax(F4-M)
UNION ELECTRICS