Manufacturer of a complete set of environmentally intelligent IOT &home comfort solutions
COMPANY PROFILE
Frank company was founded in 1993. We produce valve series products and export to 78 countries around the world, shaped with the strength and potential of the international brand.
In2008, we set our sights on the domestic heating market with our main products: brass floor heating manifold, 304 food grade stainless steel manifold, duplex supply system, mixed water integrated system, exhaust valves, temperature control valves and connection fittings. We havethe most forward-looking large waterwheel typespecial machine in the world. The spirit of craftsmanship "all through my hands, will be worry-free" is present throughout every detail of our products and designs as well as decades of innovation & cooperation, excellence, qualityservice, strict control of each product, each link. Respect quality and pursue quality with heart.
Over the past 30 years, our professionalism and unremitting efforts have forged the high quality and exquisite technology of Frank's products and systems, from independent products to the perfect combination of thermostatic multiple supply systems, from manual control to the organic combination of intelligent LOT 5G. The above has made it possible for us to achieve a smart home, comfortable home, truly accurate temperature control, complex but orderly chip circuit board programming, mobile phone App small program control, with which you can enjoy simple and convenient, humanized design, low-carbon energy saving, safety and comfort, long-lasting service time.
Frank has always been passing love and warmth with the unselfish belife of doing good things and thinking of others' benefit, creating valuable systems that protect the environment and save energy for a better quality of life for society. We are commited to being a benchmark company in the industry with a sense of commitment, mission and responsibility.
Frank Company's aim: make the whole of humanity live a smart, more comfortable, healthier, happier and better life
CONTENT
| Smartlink Heating and Cooling System Solutions 005-008 | |
| Stainless Steel Square Shaped Manifold 009-011 | |
| Stainless Steel Indented Shaped Manifold 014-017 | |
| Five-proof Intelligent Manifold 018-020 | |
| Non-condensing Compartment Manifold 021-022 | |
| Capilllary Tube Fittings 023-024 | |
| Water Mixing Systems 025-026 | |
| Actuators / Intelligent Temperature Control Displays 027-029 | |
| Inlet and Return Set Valves 030-032 | |
| Drain | Valve 033-036 |
| Temperature Control Valve 037-038 | |
| Two-way Valve 039-040 | |
| Heating Circulation Pumping Stations 041-042 | |
| Bypass Valve /Coupling Tank 043-044 | |
| Underfloor Pipes 045-046 | |
| P8pro | P8S | P8C | P4DC | R86 | R8Cpro | X16-HaiLinDN | Xpro-DaiKin | Body Sensing | Smart Switch |
| 1PC | 2PCS | 5PCS | 1PC | 4PCS | 2PCS | 1PC | 1PC | 6PCS | 25PCS |
rm y ae ae
e Se / emso uc tog n / trltrd
图ti Coti / iro uity
e /trolng ng/ trl
/g rom
hhhom
n / t 图tn C/ tfro g / trol
tttpy
HOIE HMON
Comfort:
The unique return water temperature collection method dynamically adjusts the hydraulic balance, eliminating the problem of the ground being cold and hot due to on/off of the switching actuator of the floor heating pipe.
Intelligence:
Usinga 32-bit ARMchip with powerful and accurate computing capability, the master control, based on the collected room temperature and the corresponding return water temperature, intelligently corrects the required temperature of the corresponding room through intelligent sub-room control, based on the return water temperature of each branch, and the system can be remotely upgraded and remotely maintained: it is compatible with other smart homes.
Easy Installation:
Any automatic spool can be fitted. The parallel and modular design of the actuators eliminates the need for flow metersand differential pressure bypass valves, reduces the cost of room thermostat configurations, electrical wiring, etc. and is and the underfloor heating pipes are unaffected within the length range of 30- 120m.
Stability:
Dual control of the master control panel (wired) and APP remote control to ensure stable system operation.
Energy Saving:
The use of analogue thermostatic control, dynamically adjusting the hydraulic balance of each circuit to prevent frequent boiler start and stop and the suffocation of the water circuit system, can save energy consumption of more than 20% with the mobile phone APP artificial energy saving,
IOT + Intelligent Two-unit Thermostat Sys
| Branch | L(mm) |
| 2 | 120 |
| 3 | 170 |
| 4 | 220 |
| 5 | 270 |
| 6 | 320 |
| 7 | 370 |
| 8 | 420 |
| 9 | 470 |
| 10 | 520 |
| 11 | 570 |
| 12 | 620 |
| Specifications | |||
| Material | SUS304food grade | ||
| Media | Hot/cold water and other fluids | ||
| Main Thread | G1" | ||
| Main Tube OD | 40mm | ||
| Branch(adapter) | G3/4”connects Φ16x2.0 Φ20x2.0 | ||
| Capillary Tube Fittings | Φ20×2.3 | ||
| Φ25×2.5Φ25×2.8 | |||
| Φ10x1.5 Φ 12x1.5 | |||
| Spacing betweenbranches | 50mm | ||
| Working Pressure | 2.5Mpa | ||
| Effective Spool Stroke | 3mm, (6m, matched with our actuators) | ||
| Flowmete | 0.5~4.0L/min (adjustable) | ||
| Bracket | Steel, Zinc | ||
FS1001 Manifolds
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN25 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
FS1003 Manifolds
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN251"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN251"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
| Branch | 2F~11F | |
| MEASUREMENT | suits:DN251"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
FS1005Manifolds
Branch
MEASUREMENT
2F\~12F
suits:DN251"X1"
Φ20X2.0Φ20X2.3 Φ16X2.0
FS1006 Manifolds
Branch
MEASUREMENT
2F\~12F
suits:DN251"X1"
Φ20X2.0Φ20X2.3Φ16X2.0
FS1007 Manifolds
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN251"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
FS1008 Manifolds
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN25 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
Common underfloor heating and air conditioning solutions
long-lasting period of service life; solidity and durability
Eight advantages of stainless steel:
1. Excellent corrosion resistance. Superb resistance to acid and alkaline solutions. No corrosion within 100 years.
2. Large tube with sufficient flow. Smooth interior with no water resistance.
3. Highly robust, with exceptional resistance to wear and impact.
4. Strong thermal insulation performance. It's not easy to conduct heat and can reduce heat energy loss.
5. Excellent mechanical properties, with good ductility and toughness.
6. Stable material properties. It's unaffected by changes in temperature.
7. Small expansion variables and slow thermal expansion and contraction of the material.
8. Hygienic and \_environmentally friendly, no precipitation of harmful substances or hidden water hazard.
SS304 VS Brass
| Ss304 Floor Heating Manifold | Brass Floor Heating Manifold |
| Material Performance: Noprecipitationof toxic elements and no contamination. | Precipitates lead and zinc elements. |
| Material Strength: High temperatureandpressure resistance, no deformation orbreakage. | Low material strength, fragile and weakto external impact. |
| Adaptability:+300°C, (with water in the tube)at-40°Cto+200°C | (with water in the tube)-1°C |
| Service Life: Over 70years | Regular cleaning and replacementrequired after 10-15 years of use. |
| Water Flow: clean and smoothinsideand out, no scaling and large volumn. | Easy to scale. |
| corrosion Sesistance: Strong resistanceto acid and alkaline solutions. | Weak corrosion resistance andsusceptible to patina. |
| Toughness and flexibility: Bending andstretching for durability | Crack and break easily |
| Thermal expansion: Veryslow | Rapid rise |
| Branch | L(mm) |
| 2 | 120 |
| 3 | 170 |
| 4 | 220 |
| 5 | 270 |
| 6 | 320 |
| 9 | 370 |
| 8 | 420 |
| 9 | 470 |
| 10 | 520 |
| 11 | 570 |
| 12 | 620 |
Capillary Tube Fittings
Spacing between
branches
Working Pressure
Effective Spool Stroke
Flowmete
Bracket
| SUS304food grade |
| Hot/cold water and other fluids |
| G1" G-1/4" G-1/2" |
| 40mm 50mm 60mm |
| G3/4” connects Φ16x2.0 Φ20x2.0 |
| Φ20×2.3 |
| Φ25×2.5Φ25×2.8 |
| Φ10x1.5Φ12x1.5 |
| 50mm |
| 2.5Mpa |
| 3mm, (6m, matched with our actuators) |
| 0.5~4.0L/min (adjustable) |
| Steel, Zinc |
FS1101 Manifolds
| Branch | 2F~12F | ||
| MEASUREMENT | suits:DN25 | 1"X1" | Branch adapter option |
| suits:DN25 | 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 | |
| suits:DN32 | 11/4X11/4 | Φ25X2.3 Φ25X2.8 Φ25X3.5 | |
| suits:DN40 | 11/2X11/2 | ||
| Branch | 2F~12F | ||
| MEASUREMENT | suits:DN25 | 1"X1" | Branch adapter option |
| suits:DN25 | 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 | |
| suits:DN32 | 11/4X11/4 | Φ25X2.3 Φ25X2.8 Φ25X3.5 | |
| suits:DN40 | 11/½2X11/{2 | ||
| Branch | 2F~12F | ||
| MEASUREMENT | suits:DN25 | 1"X1" | Branch adapter option |
| suits:DN25 | 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 | |
| suits:DN32 | 11/4X11/4 | Φ25X2.3 Φ25X2.8 Φ25X3.5 | |
| suits:DN40 | 11/½2X11/2 | ||
| Branch | 2F~12F | ||
| MEASUREMENT | suits:DN25 | 1"X1" | Branch adapter option |
| suits:DN25 | 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 | |
| suits:DN32 | 11/4X11/4 | Φ25X2.3 Φ25X2.8 Φ25X3.5 | |
| suits:DN40 | 11/½2X11/{2 | ||
| Branch | 2F~12F | ||
| MEASUREMENT | suits:DN25 | 1"X1" | Branch adapter option |
| suits:DN25 | 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 | |
| suits:DN32 | 11/4X11/4 | Φ25X2.3 Φ25X2.8 Φ25X3.5 | |
| suits:DN40 | 11/2X11/2 | ||
| Branch | 2F~12F | ||
| MEASUREMENT | suits:DN25 | 1"X1" | Branch adapter option |
| suits:DN25 | 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 | |
| suits:DN32 | 11/4X11/4 | Φ25X2.3 Φ25X2.8 Φ25X3.5 | |
| suits:DN40 | 11/2X11/2 | ||
| Branch | 2F~12F | ||
| MEASUREMENT | suits:DN25 | 1"X1" | Branch adapter option |
| suits:DN25 | 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 | |
| suits:DN32 | 11/4X11/4 | Φ25X2.3 Φ25X2.8 Φ25X3.5 | |
| suits:DN40 | 11/2X11/2 | ||
| Branch | 2F~12F | ||
| MEASUREMENT | suits:DN25 | 1"X1" | Branch adapter option |
| suits:DN25 | 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 | |
| suits:DN32 | 11/4X11/4 | Φ25X2.3 Φ25X2.8 Φ25X3.5 | |
| suits:DN40 | 11/2X11/{2 | ||
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN25 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN25 1"X1* | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN25 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN251"X1* | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
| Branch | 2F~12F | ||
| Interface thread | G1" | Operatingtemperature | 2~60℃ |
| Main tube dia | 37mm | Max.temperatureresistance | 75℃ |
| Distance betweenmain tubes | 210mm | Operatingtemperature | 0~5L/min0~8L/min |
| Distance betweenbranch pipes | 50mm | Max.temperatureresistance | Water 30%glycolsolution |
| Max.pressuredifference | 1bar | Branch flow | 1.03m/h |
| Max. workingpressure | 5bar | Main flow | 53m/h |
FS1114 Manifolds
Branch
MEASUREMENT
2F\~12F
suits:DN25 1\*X1\*
Φ20X2.0 Φ20X2.3 Φ16X2.0
FS1115
Stainless steel cube floor heatingradiator with ball valves
Branch
MEASUREMENT
2F\~12F
suits:DN251"X1"
Φ20X2.0 Φ20X2.3 Φ16X2.0
FS1116
Brass Intelligent Floor Heating Manifolds
Branch
2F\~12F
suits:DN25 1"X1"
MEASUREMENT
FS1117
Brass Manual Floor Heating Manifolds
Φ20X2.0 Φ20X2.3 Φ16X2.0
Branch
2F\~12F
MEASUREMENT
suits:DN25 1"X1"
Φ20X2.0 Φ20X2.3 Φ16X2.0
FS1118
Brass Forged Floor Heating Manifolds with Ball Valves
Branch
2F\~10F
MEASUREMENT
suits:DN25 1"X1\*DN20 M3/4XF3/4
FS1119
Brass Floor Heating Manifolds with High Flow Ball Valves
Branch
2F\~12F
MEASUREMENT
suits:DN25 1"X1"
Φ20X2.0 Φ20X2.3 Φ16X2.0
FIVE-PROOF DISTRIBUTION MANIFOLD.
(Anti-corrosion, Anti-scaling, Anti-condensation, Anti- Heat conduction, Anti-ultra-high and ultra-low temperature)
The significant component of distribution manifold is the heart and control core in the whole heating and cooling radiation system.
At present, the main materials used at home and abroad are brass , stainless steel and synthetic plastic. All kinds of materials have their inherent advantages and disadvantages.
Metallic materials: Temperature resistant and easy to conduct; Hard and easy to scale; Corrosion resistance and easy condensation .
Resin plastic: temperature-resistant ; non-toxic; the surface is not easy to attachment ; scaling speed is very slow . It is also an ideal thermal insulation material, however it is relatively short In news cycle, soft and low strength In strength, easy to degrade, and poor in environmental stress cracking.
So how to remove the false and retain the true, and take the advantages of each material
For this target , Tsinghua Changshan Yangtze River Delta Research Institute and Frank Company jointly developed a new type of Five-proof distribution manifold through nanotechnology , which combines brass, stainless steel , and resin plastic organically and perfectly , emerging at the right moment, which enhances the deepening and perfection of radiation industry.
Compare with a single metal material product , it is detected by a national detection institution , and has the advantage of Acid-base corrosion protection up to 99%, Anti-temperature conduction and diffusion, and improved insulation by 77%. It prevents external condensation water, and reduces the water out of 68%. It also improves 5 times for relieving the structure rate of an inner wall structure. It Anti-ultra-high to 200CC and ultra-low temperature to -50℃.
Five-proof distribution manifold takes the stainless steel as the main trunk, the tube body uses the brass valve core and the connector inside and outside double coating resin synthesis plastic . It has both the ruggedness of metal and the excellent function of plastic insulation without scaling . It is the most ideal and the most guaranteed patent products in heating and cooling radiation.
Five-proof distribution manifold is the Global pioneer product.
Advantages of Using Five-proof Nano Stainless Steel Manifold
Comparison of physical parameters of brass (Hpb59-1), stainless steel (SUS304) and synthetic plastics
Selected Values
| Material | brass (Hpb59-1) | stainless steel (SUS304) | synthetic plastics |
| Tensile Strength | Mpa≥280 | Mpa≥515-1035 | Mpa≥90 |
| Stress in MaterialDeformation | ≥120 | ≥205 | ≥40-70 |
| Elongation | ≥15 | ≥40 | 1100% |
| Hardness | Hv80 | Hv220 | Hv50 |
| Thermal Conductivity | ≥397 | ≥16.3 | ≥0.19 |
| Temperature resistance | 700-1000°℃ | 800-1200°℃ | 150-200°C |
Super Applicable Relatively durablea
| Branch | L(mm) |
| 2 | 120 |
| 3 | 170 |
| 4 | 220 |
| 5 | 270 |
| 6 | 320 |
| 7 | 370 |
| 8 | 420 |
| 9 | 470 |
| 10 | 520 |
| 11 | 570 |
| 12 | 620 |
Material
Media
Main Thread
Main Tube OD
Branch(adapter)
Capillary Tube Fittings
Spacing between
branches
Working Pressure
Effective Spool Stroke
Flowmete
Bracket
| SUS304food grade |
| Hot/cold water and other fluids |
| G1" G1/4"" |
| 40mm |
| G3/4" connects Φ16x2.0 Φ20x2.0 |
| Φ20×2.3 |
| Φ25×2.5Φ25×2.8 |
| Φ10x1.5Φ 12x1.5 |
| 50mm |
| 2.5Mpa |
| 3mm, (6m, matched with our actuators) |
| 0.5~4.0L/min (adjustable) |
| Steel, Zinc |
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN25 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
FS1202 Manifolds
| Branch | 2F~9F | |
| MEASUREMENT | suits:DN251"X1" | Φ16X2.0 Φ20X2.0 |
| Branch | 2F~9F | |
| MEASUREMENT | suits:DN25 1"X1" | Φ16X2.0 Φ20X2.0 |
| Branch | 2F~12F | |
| MEASUREMENT | suits:DN25 1"X1" | Φ20X2.0 Φ20X2.3 Φ16X2.0 |
FS1204 Manifolds
| Branch | 2F~9F | |
| MEASUREMENT | suits:DN251"X1" | Φ16X2.0 Φ20X2.0 |
three layers of gapless bonding vacuum insulation without condensation two-unit non-condensing compartment manifold
polyurethaneinfusion lamination
completeseparation of hot and cold layers
no condensation at all
the most effective triple isolation of supply
cooling and
radiant heating manifold
Application: Geothermal tube capillary radiation cooling; Ceiling and wall radiant cooling.
| TechnicalSpecifications | ||
| Material | SUS304food grade | |
| Media | Hot/cold water and other fluids | |
| Main Thread | G1/4"" | |
| Main Tube OD | 70X76mm | |
| Branch(adapter) | G3/4"connects Φ16x2.0 Φ20x2.0 | |
| Capillary Tube Fittings | Φ20×2.3 | |
| Φ25×2.5 Φ25×2.8 | ||
| Φ10x1.5 Φ 12x1.5 | ||
| Spacing betweenbranches | 50mm | |
| Working Pressure | 2.5Mpa | |
| Effective Spool Stroke | 3mm, (6m, matched with our actuators) | |
| Flowmete | 0.5~4.0L/min (adjustable) | |
| Bracket | Steel, Zinc | |
FS1301 Manifolds
| Branch | 2F~12F |
| MEASUREMENT | suits: DN32 1-1/4" |
FS1302 Manifolds
| Branch | 2F~12F |
| MEASUREMENT | suits: DN32 1-1/4" |
Branch
2F\~15F
MEASUREMENT
suits: DN251-1/4"
Branch
2F\~15F
MEASUREMENT
suits: DN251-1/4"
FS1305
UnderfloorHeating Manifold Kit with Ball Valves
Branch
2F\~15F
MEASUREMENT
suits: DN251-1/4"
FS1306
Branch
2F\~15F
MEASUREMENT
suits: DN251-1/4"
FS2001
capillary tube fittings (brass color / electroplated)
MEASUREMENT
1×Φ10
2×Φ10
FS2002 one-piece locking nut
3×Φ12
sectional drawing
MEASUREMENT
1×Φ10 2×Φ103×Φ10
MEASUREMENT
1×Φ102×Φ10 3×Φ10
MEASUREMENT
Φ10 Φ12 Φ13
FS2006 Balancing valves/flow meter images,View
MEASUREMENT
MEASUREMENT
MEASUREMENT
DN20X1½/4X11/4M DN20X1½/4X11/4F
FS5011 Electric Heating Actuators
Split
Electric Actuators
Working Pressure: 230vAC/24V
Power:2.5W/3W
Travel Time: 3-5mm
Force:110N
Connection Size: M30\*1.5mm
Housing Material: FlameRetardant PC
Length: 1m
IP Grade:IP45
Germany's Indutry 4.0
FS5004 Manual/Auto Electric
FS5008
Electric Heating Actuators
FS5012
Intelligent Thermostat
Specifications:
Operating Voltage: 5V
Temperature Control Range: 5°C to 35°C (can be modified to 5°C to 80°C)
Temperature Sensor: NTC1%
Load Current: <10A<2W
Dimension:86×86×14mm
Housing Material: PC+ABS
Mounting Hole Distance: 60mm(standard)
Product Overview
The Smartlink digital thermostat is a device for temperature control. It can accurately collect, transmit and control the indoor temperature of floor heating and air conditioning. It uses micro-computerised, fully automatic intelligent logic, using pBUS (wired)and Npitc (wireless) communication technology, designed to match the Internet of Things and telecommunication networks, with programmable timing/temperature selection; the user can select the temperature at different times of the week according to their preferences.
FS5013
A underfloor heating intelligent LCD thermostat B Intelligent LCD thermostat for central air conditioning
Product Features
1. bright LCD colour display; beautiful andgorgeous;
2. Tempered glass panels, touch controls and beeping feedback for operation;
3. Infrared remote control function (optional) ;
4. Four air speed modes to choose from: high, medium, low and automatic;
5. Switch between cooling and heating operating modes;
6. Intelligent sleep function with automatic comfort temperature adjustment
7. High reliability with large transformer power supply and relay output control.
Specifications
Operating Voltage: 220AC ±10%50/60Hz
Temperature Control Range: 18-30°C
Temperature Sensor: NTC1%
Load Current:<3A<2W
Dimension:86×86×14mm
Housing Material: PC+ABS
Mounting Hole Distance: 60mm (standard)
Product Overview
The central air-conditioning thermostat with colour LCD display is suitable for indoor temperature control of central air-conditioning fan coil series or air duct series. By comparing the indoor temperature with the set temperature, the fan coil, electric valve and electric ball valve at the end of the air-conditioning system are controlled to open and close to achieve the purpose of regulating the indoor temperature, comfort and energy saving.
FS5014
A underfloor heating intelligent LCD thermostat B Intelligent LCD thermostat for central air conditioning
Product Features
1. bright LCD colour display; beautiful and gorgeous;
2. Tempered glass panels, touch controls and beeping feedback for operation; 3. One week programming mode with intelligent temperature control at 6 times of the day;
4. Power-down setting data memory function;
5. Anti-freeze function for living rooms;
6. Floor overheating protection;
7. Precise temperature control with single temperature single control, dual temperature double control mode selection;
8. High reliability with large transformer power supply and relay output control;
9. Parameter reset function.
Specifications
Operating Voltage: 220AC ±10%50/60Hz
Temperature Control Range: 5 to 35°C(can be modified to 5°C to 80°C)
Outer temperature limit: 5 to 60°C (factory setting: 45°C)
Temperature Sensor:NTC1%
Load Current: <10A<2W
Dimension:86×86×14mm
Housing Material: PC+ABS
Mounting Hole Distance: 60mm(standard)
Underfloor Heating and Air Conditioning Smart Thermostat
FS5022 Centralised Connection Controller 180mm 8-branch central control
FS5023 Indoor temperature collectors
FS5113
Touchscreen and Push-button Floor Heating Thermostat
FS5114 Touchscreen Floor Heating WiFi Thermostat
FS5118 Manual Floor Heating Thermostat
Push-Button Floor Heating WiFi Thermostat
FS5012 Manual and Auto Electric Drive Actuator
FS5014 Thermostatic Control Head
FS6014
Angle Front Ball Valve (PPR external filament main valve)
FS6015
Angle Front Ball Valve (PPR external filament main valve)
FS6017
Angle Front Ball Valve (snap-on external screw main valve) National/European Standard
FS6018
nlet Analogue Sub-control Valve
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hot water
Working Temperature: -20°C≤T≤100°C
Test Pressure Standard: ISO5208
Pipe Thread Standard: ISO228
Note: foraluminium-plasticpipes, underfloor
heating pipes only
MEASUREMENT
1"XΦ25 1"XΦ32
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hot water
Working Temperature:-20°C≤T≤100°C
Test PressureStandard: ISO5208
PipeThreadStandard: ISO228
Note: for aluminium-plastic pipes, underfloor
heating pipes only
MEASUREMENT
1"XΦ25X2.8 1"XΦ25X3.5
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hot water
Working Temperature: -20°C≤T≤100°C
Test Pressure Standard: ISO5208
Pipe Thread Standard: ISO228
Note: for aluminium-plastic pipes, underfloor
heating pipes only
MEASUREMENT
1"XΦ20 1"XΦ25
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hot water
WorkingTemperature: -20°C≤T≤100°C
Test Pressure Standard: ISO5208
Pipe Thread Standard: ISO228
Note: for aluminium-plasticpipes, underfloor
heating pipes only
MEASUREMENT
DN203/4"X3/4"DN25 1"X1"
FS6014
Angle Front Ball Valve (PPR external filament main valve)
FS6015
Angle Front Ball Valve (snap-on external screw main valve)
FS6016
Angle Front Ball Valve (Slip-Fit type) National/European Standard
FS6017
Quick Connect Ball Valves (Plating/Brass Colour)
FS6018
Quick Connect Large Diameter Ball Valves (Plating/Brass Colour)
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hotwater
Working Temperature: - 2 0 ^ { \circ } \mathsf { C } <=slant \mathsf { T } <=slant 1 0 0 ^ { \circ } \mathsf { C }
Test Pressure Standard: ISO5208
Pipe ThreadStandard: ISO228
Note: for aluminium-plastic pipes, underfloor
heating pipes only
MEASUREMENT
1"XΦ25 1"XΦ32
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hot water
Working Temperature: - 2 0 ^ { \circ } \mathsf { C } <=slant \mathsf { T } <=slant 1 0 0 ^ { \circ } \mathsf { C }
Test Pressure Standard: ISO5208
Pipe Thread Standard: ISO228
Note: for aluminium-plastic pipes, underfloor
heating pipes only
MEASUREMENT
1"XΦ20X2.0 1"XΦ25X2.8 1"XΦ25X3.5
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hot water
Working Temperature: 2 0 ^ { \circ } \mathsf { C } <=slant \mathsf { T } <=slant 1 0 0 ^ { \circ } \mathsf { C }
Test Pressure Standard: ISO5208
Pipe ThreadStandard: ISO228
Note: for aluminium-plastic pipes, underfloor
heating pipes only
MEASUREMENT 1"XΦ20X2.0 1"XΦ25X2.8 1"XΦ25X3.5
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hot water
Working Temperature: - 2 0 ^ { \circ } \mathsf { C } <=slant \mathsf { T } <=slant 1 0 0 ^ { \circ } \mathsf { C }
Test Pressure Standard: ISO5208
Pipe ThreadStandard: ISO228
Note: for aluminium-plastic pipes, underfloor
heating pipes only
MEASUREMENT
1"XΦ25 1"XΦ32
FS6019
Inlet Analogue Subcontrol Valve
FS6020
Specifications:
Nominal Pressure: 1.6Mpa Media: cold/hot water Working Temperature:-20°C≤T≤100°C Test Pressure Standard: ISO5208 Pipe Thread Standard: ISO228 Note: for aluminium-plastic pipes, underfloor heating pipes only
Inlet Analogue Subcontrol Valve
MEASUREMENT
DN25 1"X1"
Specifications:
Nominal Pressure: 1.6Mpa Media: cold/hot water Working Temperature: -20°C≤T≤100°C Test Pressure Standard: ISO 5208 Pipe Thread Standard: ISO228 Note: for aluminium-plastic pipes, underfloor heating pipes only
MEASUREMENT
3/4"XΦ25 1"XΦ25
FS6021 Fvalv
Specifications:
Nominal Pressure: 1. 6Mpa Media: cold/hot water Working Temperature: -20°C≤T≤100°C Test Pressure Standard: ISO5208 Pipe Thread Standard: ISO228 Note: for aluminium-plastic pipes, underfloor heating pipes only
MEASUREMENT
1"XΦ25X2.81"XΦ25X3.5
FS6022 Intelligent Sub-control Valve
FS6023
304 stainless steel cut-off multifunctional valve
Specifications:
Nominal Pressure: 1.6Mpa Media: cold/hot water WorkingTemperature:-20°C≤T≤100°C Test Pressure Standard: ISO5208 Pipe ThreadStandard: ISO228 Note: for aluminium-plastic pipes, underfloor heating pipes only
MEASUREMENT
1"XΦ25X2.81"XΦ25X3.5
Specifications:
NominalPressure: 1.6Mpa Media: cold/hot water WorkingTemperature:-20°C≤T≤100°C Test Pressure Standard: ISO5208 Pipe ThreadStandard: ISO228 Note: for aluminium-plastic pipes, underfloor heating pipes only
MEASUREMENT
1"XΦ25
1"X32"
FS6028304不锈钢多功能球阀
MEASUREMENT
DN32XΦ32 DN32XΦ40
FS6029304不锈钢多功能球阀
MEASUREMENT
DN25XΦ25 DN25XΦ32
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hot water
Working Temperature: -20°C≤T≤100°C
Test Pressure Standard: ISO5208
Pipe Thread Standard: ISO228
Note:foraluminium-plastic pipes, underfloor
heating pipes only
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hot water
Working Temperature: -20°C≤T≤100°C
Test PressureStandard: ISO5208
Pipe ThreadStandard: ISO228
Note: for aluminium-plastic pipes, underfloor
heating pipes only
FS6030 304不锈钢铝塑球阀
MEASUREMENT
Specifications:
Nominal Pressure: 1.6Mpa
Media: cold/hot water
Working Temperature: -20°C≤T≤100°C
Test Pressure Standard: ISO 5208
Pipe Thread Standard: ISO228
Note: for aluminium-plastic pipes, underfloor
heating pipes only
1"XΦ20X2.0 1"XΦ25X2.8 1"XΦ25X3.5
FS6031 304不锈钢PPR球阀
Specifications:
Nominal Pressure:1.6Mpa
Media: cold/hot water
Working Temperature: -20°C≤T≤100°C
Test Pressure Standard: ISO 5208
Pipe Thread Standard: ISO228
Note: for aluminium-plastic pipes, underfloor
heating pipes only
MEASUREMENT
1"XΦ25 1"XΦ32
Extraordinary and Infinite Positioning
Quick-position automatic exhaust valve
Product Features:
The venting valve must be upwards in order to exhaust air, and the threads of the products connected to the manifold have different starting teeth, which cannot be aligned after torquing, making the use of raw materials very time-consuming and troublesome for construction and installation, and difficult to align. \_
Our company has developed a quick positioning, which is used as follows:
Patented Products, No Counterfeiting.
3. It will automatically pop up when aligned in position. If it does not pop out, simply bring it out gently. Never leaks, easy and quick to install, saves labour and time.
FS8003DrainValve with Compression Cap and Meter
SIZE
1"
SIZE
SIZE
1"
1"
SIZE
1"
SIZE
1"
SIZE
1"
SIZE
1/2"
SIZE
3/8"1/2" 3/4"
SIZE
1"
Fs8007 Manual Plug Exhaust Valve (compression cap)
SIZE
1"1"-1/4"
SIZE
1"1"-1/4"
SIZE
1/2"
1/2"
SIZE
Schematic diagram of hot and cold circulating water tank
MDN40+DN40
MDN40+FDN40
FDN40+DN40
SIZE
FDN40+DN40
MDN40+DN32
PPRΦ40+FDN32
MDN32+DN32
SIZE
FDN40+DN32
FDN32+DN32
MDN32+FDN40
SIZE
MDN40+FDN32
MDN32+FDN32
SIZE
PPRΦ40+FDN40
SIZE
PPRΦ32+FDN32
PPRΦ32+FDN40
FDN40+DN32
FDN32+DN32
FS8040
MDN40+DN40
SIZE
MDN40+DN32
MDN32+DN32
FS8041
FDN40+DN40
SIZE
FDN40+DN32
FDN32+DN32
FS8042
MDN40+FDN40
MDN32+FDN40
SIZE
MDN40+FDN32
MDN32+FDN32
FS8043
PPRΦ40+FDN32
SIZE
PPRΦ40+FDN40
PPRΦ32+FDN32
PPRΦ32+FDN40
FDN40+DN40
SIZE
FDN40+DN32
FDN32+DN32
FS8045
Water Tank Safety Components (safety valve + exhaust valve + pressure gauge) EPP black housing
Specifications:
Nominal Pressure: 1. 6Mpa
Media: cold/hot water
WorkingTemperature:-20°C≤T≤100°C
Test Pressure Standard: ISO 5208
Pipe Thread Standard: ISO228
Note: for aluminium-plastic pipes, underfloor
heatinpipesg only
FS8048
Water Tank Safety Components (safety valve + exhaust valve + pressure gauge) EPP black housing
MEASUREMENT
Connection Size:1"XΦ25X2.8 1"XΦ25X3.5
Copper visually Adjustable Differential Pressure Valve (Automatic FlowDistribution)
3bar,6bar
8bar, 9bar
MEASUREMENT
Connection Size:1/2"3/4"
MEASUREMENT
Connection Size:1\*XΦ25X2.8 1\*XΦ25X3.5
BOILER COMPONENT
FS8052
MEASUREMENT
Connection Size:3/4" 1" 11/4"
FS8047
MEASUREMENT
Connection Size:1"XΦ25X2.8 1"XΦ25X3.5
Water Tank Safety Components Connection Size: G1" Insulated Thermal Housing: black EPP Working Temperature: Max. 120°C Safety Valve Unloading Pressure : 3bar, 6bar, 8bar, 9bar
MEASUREMENT
Connection Size:1/2"3/4"
FS8405 Smartlink System
Pressure-independent dynamic balancing valve (flow control)
Function: Pressure-independent dynamically balanced electric control valve is a new type of control valve. Its role is to achieve automatic regulation and dynamic balance of flow in the piping system.
Function: Pressure-independent dynamicallybalancedelectrically operated control valves can be dynamically balanced. In piping systems, variations in flow rate can lead to uneven pressure distribution in the pipeline, thus affecting the stability and reliability of the piping system. However, the pressure-independent dynamic balance electric adjustment valve can automatically adjust the opening of the valve according to the change of flow rate, so as to realize the dynamic balance of the pipeline system. This dynamic balancing can greatly improve the stability and reliability of the piping system.
SIZE
1/2" 3/4" 1"
FS8045 Pre-meter CheckValve
MEASUREMENT
Connection Size:1/2"3/4"
FS8046 Drain Valve
MEASUREMENT
Connection Size:1/2"
FS8047 Automatic Water Refill Valve
MEASUREMENT
Connection Size:1/2"3/4"
FS8048 Pre-meter Check Valve
MEASUREMENT
Connection Size:1/2"3/4"
angle/straight
Manual Thermostatic Control Valve Angle PP-C/PERT/PB/PEX
FS7001 Self-controlled Thermostatic Valve AnglePP-C/PERT/PB/PEX
MEASUREMENT
1/2"XΦ12/16 1"XΦ16/20 1/2"XΦ15/203/4"XΦ12/16 3/4"XΦ16/20
FS7002
angle/straigh
MEASUREMENT
1/2"XΦ12/16 1"XΦ16/20 1/2"XΦ15/203/4"XΦ12/16 3/4"XΦ16/20
MEASUREMENT
1/2"XΦ12/16 1"XΦ16/20 1/2"XΦ15/203/4"XΦ12/16 3/4"XΦ16/20
FS7004
Self-controlled Thermostatic Valve (Angle PP-R)
FS7052 Self-operated TemperaturecontrolledValvet
Manual Thermostatic Control Valve (Angle PP-R)
FS7005
angle/straight
Manual Thermostatic Control Valve (Angle PP-R)
FS7006
A type/triple sealing B type/double sealing
MEASUREMENT
1/2"XΦ20 1/2"XΦ25
MEASUREMENT
1/2"XΦ20 1/2"XΦ25
3/4"XΦ25
MEASUREMENT
1/2"XΦ20 1/2"XΦ25
3/4"XΦ25
1"XΦ32
FS7007
Internal and External Wire Temperature Control Valve
C
FS7008
A type/ triple sealing B type/double sealing
1/2"X1/2 3/4"X3/4"1"X1"
MEASUREMENT
Self-controlled Temperature Control ValveAngle PP-C/PERT/PB/PEX
FS7009
MEASUREMENT
1/2"XΦ12/16 1"XΦ16/20
1/2"XΦ15/203/4"XΦ12/16
3/4"XΦ16/20
MEASUREMENT
1/2"XΦ12/16 1"XΦ16/20 1/2"XΦ15/203/4"XΦ12/16 3/4"XΦ16/20
FS7010 TRV Kits and Valves
MEASUREMENT 1/2"X1/2
MEASUREMENT
3/4"X3/4"
FS7012 Lock arm i
SIZE
1/2" 3/4" 1" 1.1/4" 1.1/2" 2"
SIZE
1/2" 3/4" 1" 1.1/4" 1.1/2" 2"
FS7014 Thermostatic H Modules
FS7015 Thermostatic H Valves
FS7016 Thermostatic Valves
FS7017 SS304 Check Valve
MEASUREMENT
1/2"X1/2"
3/4"X3/4"
SIZE
1/2" 3/4" 1° 1.1/4" 1.1/2" 2"
FS7018 SS304 Filter Valve
FS7019
Two-end Pipe ConnectorΦ16/Φ20
SIZE
1/2" 3/4" 1" 1.1/4" 1.1/2" 2"
FS7020 SS304 Mini Ball Valve
SIZE
1/2" 3/4"
FS9006
1/2" 3/4" 1° 1.1/4" 1.1/2" 2"
FS9004sprlng chEck vaLvE
FS9005 FOOT VALVE
BRASS FITTING
FS9008 FOOT VALVE
BRASS FITTING
FS8206 Fs8206 Two-way Valve
1/2" 3/4" 1"
Φ16 Φ20
Extended Brass Angle Valve
Brass Angle Valve
1/2" 3/4"
BRASS FITTING
TheFunction of the Two-way Control Valve: Requlate the flow rate of hot and cold water to set the opening of the temperature control valve to control the flow rate of the water flow.
Working Principle:
The electric heating actuator is driven to open the valve and cold and hot water enters the fan coil to provide cold or warm air to the room. When the room temperature reaches the set value of the thermostat, the temperature arrogancecommands the closing of the actuator, thus cuttingoff the water flow into the fan coil. By closing and opening the valve, the room temperature is kept in the temperature range set by the temperature control.
Connection Port: 1. Thread 2. PE-Xa 3. PPR
FS8402 Electric Heating Systems
Excellent Performance, Excellent Valve. Frank: Smartlink Analogue Energy Saving Thermostatic Water Mixing System
1. Product Energy Saving
2. Systematic Energy Saving
3. Human-made Energy Saving
Analogue Actuator Water Mixing 220V to 5V
FS3003Pump Mixer Set
Description
Suitable for M² ; the water supply temperature is not higher than 95°C.
Suitable for left or right inlet; can be changed on site to a right-flush water supply •Programmable thermostat controls both room
temperature and underfloor heating water temperature. •Accurate monitoring of underfloor heating water
temperature.
•Temperature-limited water cut-off protection, adjustable from 35°C to 65°C
•Factory setting: If the measured temperature of the mixer pipe is below 35°C, the pump stops and starts running if it is above 45°℃.
FS3005Pump Mixer Set
FS3006Pump Mixer Set
FS3007Pump Mixer Set
Heating Circulation Pumping Station
Application:for heating systems, installed between heating boilers and heating equipment (floor heating, radiators, hot water storage tanks) to circulate the heating system medium (mixture of water and glycol)
Heating Circulation Pumping Station
Specifications
Wheelbase:125mm
Connection: G1-1/2(outside)×G1(inside)
Working Temperature: media temp. <=slant 1 1 0 ^ { \circ } { C } Rated Pressure: Max. 10bar
Insulated Shell: black EPP
Kvs value: Manual thermostat type:2.5m²/h, 3.2 m²/h Dynamic thermostat type/Straight-through high temperature type: 4.8 m2/h
Circulation Pumps: GrundfosUPM3 HYBRID 25- 70 180 ACA
| Parameter: | Main Tube: 1-1/4” |
| Branch: | 2-8 |
| Adapter: | Φ20/25 |
FS8503 Hydrobalance Distributor
| Parameter: | Main Tube: 1-1/4” |
| Branch: | 2-8 |
| Adapter: | DN20/25 |
FS8505 Hydrobalance Distributor
1. wireless temperature control
2. scale resistance settings
3. micro bubble exhaust
4. accessible link
5. effectively regulate the smooth
equalization of water flow
| Parameter: | Main Tube: 1-1/4” |
| Branch: | 2-8 |
| Adapter: | Φ20/25 |
| Parameter: | Main Tube: DN32 |
| inlet return valve: | 1" |
| Branch: | 1" |
FS8504 Hydrobalance Distributor
| Parameter: | Main Tube: 1-1/4” |
| Branch: | 2-8 |
| Adapter: | DN20/25 |
FS8506 Hydrobalance Distributor
| Parameter: | Main Tube: 1-1/4" |
| Branch: | 1-1/4" |
| Branch: | 1" |
theFunctionofdifferential pressure bypass:
The differential pressure bypass valve is installed at the end of the manifold and applied to the protection of the floor heating pipe group. When the heating pipeline system runs variably, the system flow becomes smaller, resulting in an increase in differential pressure, and when the differential pressure exceeds the set value, the check valve automatically opens and the overpressure cycle drains water to protect the floor heating pipe pressure from exceeding the operation.)
| Model | ThreadedConnection | ThreadedConnection | Volumn(ml) | ReferenceArea | Size |
| 20 model) tank 63mm connector DN20 | 3/4" | 6divide | 747 | 50~150 | Φ63 |
| 2 inlets 2 outlets)76mm connector DN25 | 1" | 1cun | 1405 | 100~300 | Φ76 |
| 32 model) tank 89mm connector DN32 | 1-1/4" | 1.25cun | 2673 | 300~400 | Φ89 |
| 40 model) tank 102mm connector DN32 | 1-1/4" | 1.25cun | 3511 | 400~500 | Φ102 |
| 50 model) tank 133mm connector DN40 | 1-1/2" | 1.5cun | 6804 | 600~1200 | Φ133 |
| tank 133mm connector DN50 | 2cun | 6804 | 600~1400 | Φ133 | |
| 2 inlets 4 outlets) connector DN25 | 1" | 1cun | 1899 | 200~600 | Φ76 |
| DN15 | 1-2 | 4divide | Exhaust and drainage | ||