2 CONTENTS
3
22 Powerful cooling & heating
·High-efficiency scroll DC inverter compressor with EVI
·Double C high efficiency condenser
·DC inverter fan motor
·High efficiency axial fan
·36°C Three-stage supercooling technology*
·Intelligent inverter technology
·Air-cooled & refrigeration-cooled technology
04 Company Profile 90
·Intelligent Control
·Non-polar CAN bus communication technology
·Multiple control solutions
·VRF WiFi & APP control solution
·AHU connection kit
·Intelligent Control System
Intelligent-operation &
maintenance control
30
·DC inverter scroll compressor
·\"2-1\"loop design
·Stepless inverter technology
·Four seasons energy-saving mode
·Multi-priority modes, VIP priority service
High efficient energy-saving
& environmental friendly
40
·Six levels oil return technology
·High precision refrigerant control technology
·Wide voltage range
· -30°C~56°C Ultra wide operating temperature range
·Pressure self-regulating technology
·Triple backup function
·Rotation function
·Multiple protections
·Anticorrosion design
·Electronic control board SMT
·Placement technology
·Anti-snow function
·Fault self-check
Stable & reliable performance
34
·Constant temperature
·Silent-mode
·Fresh air
·Comfortable soft wind
·Auto restart function
·Intelligent defrost technology
Comfortable & healthy
environment
56 ODU lineup & Specifications
94 Installation options
50 Convenient Installation and
Maintenance
·15 basic modules, satisfy all kind of requirement
·Super long refrigerant pipeline design
·Single system can connect 80 IDUs
·Highest static pressure for outdoor unit
·Convenient for the transportation
·One-touch commissioning function
·Non-polarity communication connection
·360°pipe connection design
·Emergency power-off function for IDU maintenance
·Commissioning software
·Auto-addressing function
69 IDU lineup & Specifications
·360° Q8 cassette
·Compact cassette
·Low ESP Slim duct
·Free static pressure duct
·High static pressure duct
·Fresh air duct
·Wall-mounted(External EXV)
·Wall-mounted(50Hz Built-in EXV)
·Ceiling & floor
·One-way cassette
·Two-way cassette
* : Suitable for some models
4 8
ABOUT TCL GROUP
COMPANY SNAPSHOT
TCL, an acronym for \"The Creative Life\", encapsulates the essence of creativity
as it permeates every facet of our lives. Creativity blossoms in an environment of
empowerment. It is the vital force that inspires the smallest and biggest aspects of life.
TCL always puts people first, using technology to drive creativity, to transform the world.
and to empower lives.
Total Revenue
Countries & Regions
Global Employees
R&D Investment in Past 6 Years
Global Users
billion billion
billion
USD USD 43.13 + +
150,000+
8.3
1.3
(~RMB 312 billion+) (~RMB 60 billion+)
160+
Patent Applications
117,878
4
5
5
6 TCL has steadily increased its global brand influence through various strategies, including
partnerships with top global IPs, sports marketing, and entertainment marketing.
Official Partner of NFL
(North America & China)
Official Sponsor of
CONMEBOL Libertadores
Premium Partner of Spain
National Football Team
Officlal Global Partner of
Arsenal Football Club
Official Partner of
Germany Men's National Football Team
(EU & China)
Naming Rights Partnership withTCL
Chinese Theatre in
Hollywood
Official Partner of AFL
(Australia)
Official Partner of
Italy National Football Team
GLOBAL BRANDING
7
TCL & IOC annouce long-term global TOP Partnership through to 2032.
TCL BECOMES OLYMPIC PARTNER
8 TCL AC
MILESTONES
The foundation of TCL
Air Conditioner Division
The foundation of TCL
Commercial Air Conditioning
Manufacturing Base
Recognized as the
National Torch
Program Key
High-Tech Enterprise
TCL AC was
awarded the China
Top Brand
Designation
The Jiujiang factory was put
into operation
Over 10 million units annual
production and sales volume
Ranking top five in the industry
1999
2003
2010
2017
2007
9
The brand value proposition
has been upgraded to \"Your
Trusted Expert in Healthy Air\"
Construction of Guangdong
Wankezi
The TCL AC Wuhan Intelligent
Manufacturing Industrial Park
commenced full operations
Annual production and sales
exceeded 16 million units
The TCL AC Guangzhou
Intelligent Manufacturing
Industrial Park was inaugurated
in the Guangzhou Nansha Free
Trade Zone
Production and sales volume
exceeded 20 million units
The TCL Brazil Air Conditioner
Factory and the TCL
Commercial AC Intelligent
Manufacturing Industrial
Park officially commenced
operations
Annual production
andsales reached the top
four in the industry
2020
2022
2024
2023
2021
10 Al Energy-saving
Technology Gold
Award
CF Silver
Award
Brand Award for Smart
Technology Innovation
EISA Award - Best
Product EISA Award
Home Theater
Gold Award (TCL)
Red Dot Product
Design Award
Honor Certificate-China
Top 10 AC Brand
Soft-wind
Technology Award
GlobalCES
Top Brands
Eleven Global Leading
Technologies
Recognition
CECA Energy Conservation
Contribution & Technological
Progress Award
TCL Whisper Q-Series
Window AC
Red Dot Winner
TCL Fresh Air Conditioner
Series Red Dot Winner CAlS Award for
Leading
Fresh-air Brand
2025 (IFA)
2023 2023
2020~2021 (CAIS)
2019 2019 (IFA) 2018 2020 (CHEAA) 2020 (CAIS)
2022 2022 2025 (CES) 2023~2024 GLOBAL HONOR
TCL Air-Conditioner Awards
TCL Industries Awards
11
Red Dot Product Design
Award C2 Series
iF Design Award 2020
(TCL RAY.DANZ SoundbarTS9O3O)
CAlS Award for Special
Contribution to
China AC Industry
National Green
Factory Recognition
AWE Award for
Excellent Product
Smart Manufacturing
Award CMF Design Award AWE Award INTERTEK- Recognized
SATELLITE
Laboratory
CAIS Award for
Special Contribution
to China AC Industry
CAIS Award for
Outstanding
Channel Performance
CHEARI Good
Product Award
China Quality
Certification
2021 2020
2021 2021 (ChinalOL.com) AWE 2021
2023~2024 2023~2024 2023 2023
12 Founded in 1999, TCL Air Conditioner has 12 global bases and over 38 million units of
annual capacity. With a full lineup covering residential, commercial, and special ACs, TCL
leads in healthy and intelligent air solutions. Backed by 1,000+ R&D experts, it pioneers 11
core technologies, including Deep Sleep Smart Fresh Air and AI Energy-saving. Focused
on digitalization, intelligence, and green development, TCL is building world-class smart
manufacturing to become a trusted global brand in healthy air and thermal management.
Mission Make it easier for you to enjoy healthy and green life brought by air.
Vision To become a reliable leading brand in healthy air management,
heat pump and thermal energy management.
ABOUT TCL AC
13
Established in 1999
Employees R&D centers Manufacturing
bases worldwide
Countries and regions
of business presence
15,000+ 5+ 12+ 160+
14 Global NO.1 Fresh Air AC Sales
NO.2 in AC Exports
GLOBAL RANKING
Global
NO.
Fresh Air AC
1 NO.2
*Global No.l in Household Fresh Air AC Sales (Shangpu Consulting 2024)
*Top Exporter among Chinese AC brands (ChinalOL 2024)
AC Exports
15
16 POWERFUL GLOBAL
SUPPLY CHAIN
Top 12 Production Bases Worldwid
38 Million Units/Year
Brazil
Argentina
Brazil Factory
Argentina Factory
17
Zhongshan
No.1 Factory
Bulk Parts
Factory
Commercial
Factory
Zhongshan
No.2 Factory
Rechi Compressor
Factory
Wuhan
Factory
Guangzhou
Factory
Wankezi
Factory
Jiujiang
Factory
100+ 140+
Certificates in Countries and Regions Worldwide
China
Indonesia Indonesia Factory
18 SMART MANUFACTURING
SYSTEM DEVELOPMENT
Al-Powered Manufacturing
On Al-driven lines, one AC rolls off the production line every 7seconds
19
High-Quality Development
Through digitalization, intelligence and green
transformation, in past 7 years production efficiency has increased 100%
20 LABS AND QUALITY
MANAGEMENT
COMPLETE MACHINE LABS
Noise Test
Enthalpy Difference Labs Noise Labs
Stimulation Technology 300+ Whole Unit Tests
Reliability Test Comfort Test
GLOBAL TOP BRANDS STANDARDS
70+ 10+
Land Area
15,000m2
+
21
Testing Devices Detectability Key Awards
600+ Whole-Process Inspection Procedures
Enthalpy Difference Lab High Drop Test
300+ 300+ 10+
22 The TMV6+ Full DC Inverter VRF system leverages premium
components, including internationally renowned compressors,
DC motors, and high-precision EXVs. This integration of
advanced technologies enables the system to deliver superior
cooling and heating performance.
DC inverter
compressor*
* Note: Applicable to partial models
DC inverter
fan motor
36℃ Three-stage
supercooling technology*
Intelligent inverter technology
Air-cooled & refrigenant-cooled
technology for main control board
Double C-type high efficiency
heat exchanger
High efficiency axial fan
POWERFUL
COOLING AND HEATING
22
23
23
24 High-efficiency scroll DC inverter compressor with EVI*
Enhanced vapor injection technology
Low fuel discharge and
reduction design
Foreign body prevention
technology
Axial flexible design
Select the material of the
high-strengthpump body
High-reliability two-stage oil
supply
Efficient oil film sealing
design
Asymmetric vortex line
High efficiency centralized coil motor
Large displacement combined
with wide frequency range
Exhaust anti-reverse design Multi-stage pressure relief pump High reliability bearing design
injecting part of the gaseous refrigerant
into the compression chamber can greatly
improve the low-temperature heating
capacity and effectively reduce the exhaust
temperature.
internal optimization of oil circuit
circulation, local oil blocking
design, to achieve low oil
discharge rate;
oil pool filter, suction filter,
enthalpy increase filter, all-round
protection compressor, improve
reliability.
Using new asymmetric scroll profile, reduce leakage loss, reduce ineffective suction overheating, more suitable for APF
conditions, improving compressor efficiency.
through the back pressure
adjustment to achieve the axial
floating of the moving disc,
improve the overall reliability and
performance of the compressor;
combined with the product design
and use range, the strongest
material is QT400 to ensure the
combined with centrifugal oil supply reliability of the monomer;
and differential pressure oil supply,
to ensure the full lubrication of each
friction under different speeds and
different controls;
hydrodynamic lubrication, oil
film sealing of the compression
chamber, effectively reduce
friction, improve performance
and reliability;
select asymmetric line to
effectively reduce overheating
losses and leakage losses, and
improve the efficiency of the unit;
excellent groove design, to ensure the
energy efficiency of each frequency;
speed range 14~160rps,
displacement up to 96cc, strong
power, expand the scope of usage.
exhaust valve adopts check
valve to effectively prevent liquid
compression and improve the
reliability of working conditions
with liquid;
all three bearings are PTFE coated
plain bearings with low noise and
vibration to ensure long-term
reliability;
dynamically adjust the intermediate
pressure according to the operating
conditions to prevent overcompression under low compression
ratio and improve the operating
efficiency of low load;
1.1
1
2
3
4
5
6 7 8
9
1
2
3
4
5
6
7
8
9
10
12
13
11
10
11
12
13
Powerful Cooling and Heating
High efficiency centralized coil motor
into the compression chamber can greatly
improve the low-temperature heating
capacity and effectively reduce the exhaust
combined with centrifugal oil supply
and differential pressure oil supply,
to ensure the full lubrication of each
friction under different speeds and
excellent groove design, to ensure the
energy efficiency of each frequency;
1
2
3
4
5
6
7
8
9
10
12
13
11
25
Dual-Mode Enthalpy Enhancement Technology
Our Dual Enthalpy Enhancement Technology ensures exceptional performance in extreme conditions, providing
strong cooling at 56°C and powerful heating at -30°C.
It intelligently manages refrigerant flow in both modes. In cooling, it increases circulation and subcooling to
prevent noise after long pipe runs. In heating, it injects vapor into the compressor to boost refrigerant flow when
outdoor temperatures plummet. This results in a reliable, stable system capable of effective heating even at very
low temperatures.
Enhanced Vapor Injection (EVI) with Two-Stage Compression
>>
Refrigerant circulation
is increased through
vapor injection.
Enthalpy
The evaporation capacity of the ODU is enhanced
m+ △ mm Increase in refrigerant flow
Air jet + gas
>>Asymmetric vortices
In view of the high pressure characteristics of R410A refrigerant, the compressor
strengthens the bearing structure and adopts the design of asymmetric scroll
disk, which has the following advantages over the symmetrical scroll disk:
Reduce refrigerant leakage and improve efficiency;
Two adjacent chambers have small pressure difference, small
vibration and more mute;
Prevent over compression, prolong the service life of the compressor.
Motor rotor with neodymium magnetic material
Neodymium, an artificial permanent magnet, is one of the strongest
magnetic materials to date. The magnetic force of neodymium
magnet is 10 times that of common ferrite magnet. Under the same
volume, the electromagnetic field intensity is stronger, the starting
torque is larger, and the operation efficiency is higher.
>>
Neodymium Magnets Ferrite Magnet
Pressure
Traditional VRF
Enthalpy
Gas
Pressure
Enhanced Vapor Injection (EVI) Compressor
Main throttle valve Plate heat exchanger
Auxiliary throttle valve
Increase refrigerant circulation
Enhance the indoor unit capacity
Enhanced Vapor Injection (EVI) Compressor Improve the degree of supercooling, strengthen the evaporation capacity
26 The Double C-type compact heat exchanger features a super-large surface area. This design not only increases
heat exchange efficiency but also reduces system pressure loss, resulting in superior performance under heavy-load
conditions.
*Note: Only for 34HP and above Double C-Type heat exchanger Traditional VRF
This new structural design optimizes system performance under partial
loads while minimizing the unit's overall footprint.
36HP occupies only 1.6055m2
,
which is 21.4% less than the previous generation
Heat exchanger adopts the perfect combination of multi-coated hydrophilic aluminum foil heat exchange fins
and high-efficiency internally threaded heat exchange copper tubes, which greatly improves the heat exchange
efficiency and enhances the corrosion resistance and oxidation resistance of the heat exchanger.
The internally grooved surface of the
copper tube increases the refrigerant's
surface area contact, directly enhancing
the heat exchanger's thermal conductivity
and overall performance.
The use of multiple rows of smalldiameter tubes with reduced
spacing increases the tube count
per unit length, thereby significantly
expanding the heat exchange area
and boosting efficiency.
The hydrophilic aluminum foil promotes condensate to form a thin, rapidly draining
film instead of discrete water droplets. This increases the effective heat exchange
area, accelerates the rate of heating and cooling, and eliminates acoustic noise
caused by airflow obstruction.
φ7 Heat Exchange Copper Tube Internally threaded copper tubes
Lubricating layer
By breaking the surface tension of
water, the system ensures rapid drainage
of condensation and meltwater. This
minimizes the insulating effect of
water lingering on the coils, leading to
enhanced heat transfer and increased
cooling capacity.
Ensure that the air conditioner is not
easy to form frost when heating.
The heat exchanger is designed to resist
corrosion from aggressive gases.
Hydrophilic coating
Corrosion resistant coating
fins
Hydrophilic aluminum fin
Powerful Cooling and Heating
36HP
Reduction from
the TMV6+S
21.4%
This new structural design optimizes system performance under partial
1.2 Double 'C' type heat exchanger*
27
High voltage (concentrated coil) DC motor
750mm Large size axial fow fan
The outdoor unit fan motor adopts a high-voltage
centralized winding DC motor, which has a more stable
and reliable output, effectively reduces losses and
improves operating efficiency.
Reduced coil height, reduced copper loss, higher
efficiency in low and medium speed zones, and
higher APF energy efficiency.
The outdoor unit fan adopts φ750mm super-size wind wheel, compared with ordinary air conditioner φ540mm
dual fans, it has sufficient air volume, higher heat exchange efficiency and lower noise.
The fan is steplessly adjusted according to environmental conditions and air-conditioning load conditions, and is
matched with the compressor's stepless frequency conversion technology, so that the system runs more stable and
reliable.
Fan speed Stepless speed regulation
Low
High
1.Accurately adjust the refrigerant pressure to
improve the reliability of the unit;
2. The motor speed is adjusted quickly to better
adapt to the rapid changes in air-conditioning load.
Average speed
90Hz
0
1.3
1.4
750mmSuper size fan
+
φ φ 540mm Common dual fans φ 540mm Common dual fans
VS
Concentrated coil motor
Improve motor efficiency
And reduce motor noise
Neodymium magneto rotor
The original rotor The new rotor
28 This design elevates heat exchange performance by integrating a 3-stage subcooling cycle—which increases the
unit mass refrigeration capacity and lowers flow resistance—with an electronic expansion valve that delivers precise,
stable control.
When the outdoor environment is35 ℃ , the outlet refrigerant of the heat exchanger is cooled to 37.1 ℃ , and the
primary and secondary supercooling can achieve degree of 11.2℃ .
A high-efficiency plate heat exchanger is employed as the secondary subcooler to cool the 37.1°C refrigerant
down to 36°C. This subcooling process reduces refrigerant flow resistance, which in turn enables the use of longer
piping runs. These improvements collectively contribute to higher system energy efficiency, enhanced cooling and
heating performance, and increased overall reliability
Common
Refrigerant cooling temperature at 35℃ Condenser + supercooler
Plate heat exchanger Schematic diagram of plate heat exchangercirculation
TCL
Normal temperature and
high pressure refrigerant
Low temperature and
low pressure refrigerant
Temperature
Drop
1 1.2°C
Pressure
Enthalpy
* Note: Applicable to some models
Powerful Cooling and Heating
First
Second
Supercooled liquid
refrigerant
Gas liquid two phase
mixing state
Gaseous
Refrigerant
compressor
ODU IDU
Heat exchanger The first stage
of supercooling
The third stage
of supercooling
Heat exchanger
Secondary supercooling
1.5 3-Stage subcooling technology to achieve 36°C subcooling
29
Intelligent Inverter
Surrounding refrigerant cooling technology
The unit uses multiple sets of high-precision, high-efficiency and high-reliability intelligent
inverters to control the compressor and fan motors, making the control more flexible, efficient and
intelligent.
The outdoor unit's inverter module is cooled by refrigerant to ensure that the inverter module can be
effectively cooled in a high-temperature environment, reduce the working temperature of the module
board, and improve the reliability and service life of the electronic control system. It also prevents
poor heat dissipation under extreme conditions, such as due to the periodic stop of the fan.
Intelligent inverter
1.6
1.7
1.Suppresses high-order harmonics and torque fluctuation
to achieve lower vibration and quieter operation.
2.Enables smooth starting by reducing inrush current,
thus minimizing grid impact and widening the
compressor's operational frequency band.
3.Maintains stable performance within a 290V-460V
voltage range, ensuring reliability under fluctuating power
conditions.
4.Features comprehensive safeguards against electrical
and thermal faults to protect system integrity and ensure
continuous operation.
80°C
60°C
The wraparound refrigerant radiator can stably and efficiently take away the
heat in the frequency conversion module of outdoor unit, improve the electrical
reliability of the unit when working in high temperature environment, and
ensure stable and safe operation.
+
The heat dissipation plate is fitted 360°
tightly with the refrigerant tube, effectively
reducing the contact thermal resistance
between the copper tube and the heat
dissipation plate, and the heat dissipation
performance is superior.
Air cooling heat dissipation
Electric control system
Enhanced fan ventilation improves
cooling to ensure stable and reliable
system operation.
Refrigerant radiator
The cooling plate
Refrigerant pipe
Temperature drop
30 The global climate is facing severe challenges, in order to achieve the
\"dual carbon\" goal, it has become an urgent issue for enterprises to
control carbon emissions effectively, improve energy efficiency and reduce
energy consumption. TCL CAC follows the product design concept of high
efficiency, energy saving and low carbon, use high-quality components
of efficient refrigeration and leading refrigerating technology, to achieve
building air-conditioning systems Integrate the goal of green, reliable and
efficient energy management.
HIGH EFFICIENT
ENERGY-SAVING AND
ENVIRONMENTAL FRIENDLY
30 Stepless inverter
technology RoHS certification
Variable evaporating/condensing temperature
adjustment technology
R410A refrigerant High energy-efficient
compressor
31
31
32 High Efficient Energy-saving and Environmental Friendly
2.3High efficiency \"2-1\" refrigerant flow
The gas-liquid mixed phase refrigerant offers superior heat transfer efficiency compared to purely gaseous or liquid
phases. This circuit is designed to maximize this advantage by simultaneously increasing both the proportion of liquid
refrigerant and its flow velocity, thereby significantly enhancing the overall heat exchange effectiveness.
2.2
Gaseous
Refrigerant
Gas-liquid
mixed phase
Liquid
Refrigerant
Common
2-1
Raise the liquid refrigerant in the heat
exchanger
To improve the heat transfer
efficiency
Gaseous
Refrigerant
Liquid
Refrigerant
Gaseous
Refrigerant
Liquid
Refrigerant
Gas phase Liquid Gaseous
Refrigerant
Gas-liquid
mixed phase
Liquid
Refrigerant
2.1 DC inverter scroll compressor*
By utilizing an asymmetric scroll structure, the DC inverter compressor significantly reduces refrigerant leakage
losses during intake and compression, thereby improving its efficiency and operational reliability
Optimized asymmetric vortex line
Suction directly
Dynamic Intermediate Pressure Control
Concentrated winding motor
Using new type of asymmetric scroll profile can reduce leakage loss and ineffective suction
overheating, which is more suitable for APF conditions and improves compressor efficiency.
Small suction preheating, high volume efficiency
By dynamically regulating the intermediate pressure, the system achieves optimal axial
flexibility. This results in superior scroll interaction, significantly improving the compressor's
reliability and operational efficiency.
The concentrated winding motor features a reduced coil height, which lowers copper
loss and achieves higher efficiency in the mid-to-low speed range. This makes it ideal for
applications requiring high Annual Performance Factor (APF).
Variable evaporating/condensing temperature regulation technology
The self-adaptive adjustment of evaporating and
condensing temperature can ensure that when the
air conditioner is running, the refrigerant flow can be
accurately controlled according to the demand, and the
evaporating/condensing temperature can be automatically
adjusted to reduce temperature fluctuation, to achieve
the effect of energy saving and constant temperature.
2.3
Too hot
Too cold
26°
TMV6+ Ordinary
±0.5°C
Difference in
temperature big
26°C
Time
Hot
Cold
33
The operating speed of the DC inverter compressor can be adjusted continuously and freely according to the change
of the system capacity. The accuracy is higher, the stepless frequency conversion is realized, and the sub-adaptive
control technology is combined, and the capacity output is automatically adjusted according to the actual control
load to ensure a higher level of accuracy. Smooth change curve to meet higher demands for comfort. TCL 's TMV6+
can only use broadband compressors and powerful inverter control motherboards for multiple connections. The
compressors operate at 0-480Hz broadband, which has more capacity and can better cope with various complex and
harsh extreme conditions.
The unit has industry-leading EER and Integrated Part Load Value IPLV (C)
480
10
The compressor adopts 180° sine wave vector drive
technology, which can obtain an ideal smooth sine wave
curve, so that the motor runs smoothly, the electric energy
efficiency is higher, and the harsh sound is reduced.
Ve c t o r c o n t r o l t e c h n o l o g y e f f e c t i v e l y
suppresses high magnetic harmonic current and
electromagnetic noise, and has passed the national
EMC electromagnetic interference test
Frequency
Infinitely
Adjustable-speed
Multistage
Regulation
common
time time
current current
voltage voltage
Rectangular
wave
Rectangular
wave
TCL
2.4 0~480Hz stepless frequency adjustment
Select the automatic energy-saving mode, the system optimizes
output according to changes in ambient temperature, realizes
automatic control of energy-saving in all seasons, and improves the
overall energy efficiency of the unit's all-season operation.
2.5 Four seasons energy-saving mode
Multiple priority modes
Multiple priority mode options deliver greater flexibility and convenience to meet customer requirements.
2.6
VIP
priority
First
priority
Mode following
(Customized)
Cooling
only
Heating
only
Cooling
priority
Heating
priority
*After setting one unique master indoor unit and enabling the custom mode following function, all other active indoor units will be forced to follow the operating mode of the master unit.
34 The demand for healthier indoor environments is rising, making
superior air quality in buildings a key priority. In response, TCL's
intelligent VRF systems are pursuing innovation to deliver
comfortable, clean, and healthy air-elevating everyday living to a
higher standard.
Extreme fast
cooling and heating
Silent-mode
Constant
temperature
COMFORTABLE AND
HEALTHY ENVIRONMENT
Fresh air
Comfortable
soft wind
Intelligent defrost
technology
Auto restart
function
34
35
35
36 Multiple sensors detect the real time temperature of the system to make sure the indoor temperature fluctuation
within ±0.5°C.
The outdoor unit has multiple electronic expansion valves, which can adjust the refrigerant circulation and control the
compressor overheat accurately to get a precise temperature control.
Can detect accurate temperature
with precision 0.5°C
This technology is mainly used to increase the refrigerant flow and improve the cooling effect when the indoor side
refrigerant flow is insufficient.
High precision and sensitivity
can detect the pressure
fluctuation quickly and
accurately.
Multi-electronic expansion valves
High-precision temperature sensor
Refrigerant liquid by-pass technology
Dual pressure sensors
Comfortable and Healthy Environment
Automatically open/close
Electronic
expansion valve
Electronic
expansion valve
Max. 80 IDU
Check valve
3.1 Constant temperature
Electronic expansion valve
Refrigerant pipe
Supercooled
electronic
expansion valve
Electronic
expansion valve
for heating
Check valve
filter
supercooler
Level
High control accuracy
480
37
Multiple silence technology
The structure of each component is involved in optimized airflow analysis, which can not only
operate with low noise, but also ensure the air volume and operation effect of the outdoor unit.
3.2
New designed
compressor with less
vibration and low noise.
The upgraded pipe system design reduce pipe
system vibration at most.
noise
Ability
Load
Volume
IDU total load
Standard model
Silent night
Ultra silent operation
Common CAC
3D simulation design with less
noise and vibration.
Lower noise scroll
compressor
3
Stepless fan speed
control with less
vibration design.
2 Inverter fan motor
Adopt 4 biger size fan blades and CFD simulation
design to get bigger air volume, reduce the noise.
13 Fan blade design
The metal panels have
stronger strengthto
reduce noise
Higher air volume, less
noise and vibration.
1 Air outlet grill
9
Built-in air guide design
reduce air resistance and
reduce noise effectively
12 New design of wind guide
Refrigerant flow noise
silencing treatment
Double-layer insulation
for compressor.
Jet silencer design
Rubber pads fix the pipes
3D simulation chassis design 3D simulation pipe design
4 7
8
11
10
5 6
13 items of silent improvments
The outdoor unit can automatically detect and record
periods of peak ambient temperature. Once triggered, it
initiates a silent mode after an 8-hour delay. This mode
operates for 10 hours, maintaining a noise level as low as
45 dB(A) before the system reverts to normal operation.
In this mode, the running noise of the system will be
reduced to be 40dB(A).
Night mode Enable
Night mode
Peak outdoor
temperature
End
Night mode
8hrs 10hrs
Minimum reduction
15dB(A)
Reduce pipeline structure
noise and vibration
Night silent mode Super silent mode
keeps refrigerant in full liquid
state when passing through
indoor throttling components,
reducing refrigerant noise.
Subcooling Silent
Technology
38 Comfortable and Healthy Environment
Intelligent defrost technology
The system can automatically decide the time to defrost according to the operation data and heating capacity.
Under high humidity condition, the system will defrost in advance to keep the room comfortable.
During defrosting, the system will shut off the indoor to avoid the cold air .
3.3
Common defrost Defrost Defrost
Defrost
Defrost Defrost
Defrost
Heating
operation
Heating
operation
Reduce
defrosting tims
Reduce
defrosting time
Reduce
defrosting time
Reduce
defrosting times
Heating
operation
Heating
operation
Heating
operation
Heating
operation
Heating
operation
TCL Intelligent
defrost
Defrosting without stop,
reduce defrosting time and times
Common defrost Heating capacity
Intelligent defrost Time
39
40 Built on a foundation of advanced manufacturing and deep
technical expertise, TCL's commitment to quality is embodied in
our VRF systems. They are engineered to deliver stable, efficient,
and reliable performance, even under complex and variable
operating conditions.
Inverter module cooling
protection technology
High precision refrigerant
control technology
Pressure self-regulating
technology
Six levels oil return
technology
- 30 ° C ~ 56 ° C
Ultra wide operating
temperature range
Triple backup function
Rotation function Multiple protections
STABLE AND RELIABLE
PERFORMANCE
40
41
41
42 Oil balancing system improves compressor oil
storage and reliability, which also ensures the unit
in good performance in cooling / heating mode.
Automatic oil balancing
Level 1
Level 6
Oil /Mist separation
Oil block points
Centrifugal separation
Gravity separation
Efficiency off oil separation:99%
Intelligent oil
balancing control
Low pressure sensor
+
+
+
Stable and Reliable Performance
Oil return from the distributor
ODU.1
Gaseous separation gas
ODU.2
Gaseous separation gas
4.1 6-Stage oil return technology
The VRF system have sufficient and balanced oil in working condition to ensure safety and avoid potential oil shortages.
TMV6+ is at the leading position on the oil separate, oil return, oil balance and storage technology. The oil system
equipped with precise 6 grade management to make sure compressor safety, stability and reliability.
Multistage Oil Control Technology
Level 1: Compressor internal oil separate
Level 2: Compressor external oil separate
Level 3: High-efficiency centrifugal oil separator
Level 4: Oil balance pipes between compressors to ensure compressors running normally
Level 5: Automatic oil balance system improves the compressor reliability
Level 6: Smart oil return program to ensure the oil return completely
Level 1
Oil return from the distributor
Level 2
Level 3
Level 4
Level 5
43
4.2 High precision refrigerant control function
The upgraded technology allows the system to manage the volume of refrigerant,and also reduct the refrigerant in
entire system and increase efficiency.
Liquid bypass control technology use multi-electronic expansion valve, it can adjust the refrigerant flow and control
the overheating degree of the compressor, ensure the compressor to be highly efficient, safety and reliable.
Automatically open/close
Electronic
expansion valve
Silent electronic expansion valve used for
indoor unit, precisely control refrigerant flow,
improve the comfort and reliability.
Electronic
expansion valve
Electronic
expansion valve
Electronic
expansion valve
Max. 80 IDUs
Check valve
4.3 Wide voltage range
The unit can operate in the range of
voltage 290V~460V (International
standard voltage 380V±10%),satisfy
all kinds of voltage conditions.
290V
460V
International Standard
342~418V
44 4.4 Wide operation temperature range -30°C ~ 56°C
Wide operation range, cooling:-15°C~56°C, heating: -30°C~28°C.
4.5Pressure self-adjustment technology
Pressure sensor is used to check system pressure, and adjust compressor operation frequency, fan speed, electronic
expansion valve, to ensure the system with the best performance
High pressure sensor Cold suspected device
Low-pressure sensor feedback
the suction pressure, so the
unit can adjust quickly, to
ensure the high stability of the
system.
Compare system
pressure with the best
pressure value per five
seconds, and adjust the
motor speed in time.
Monitor high pressure changes,
protect compressor from the
impact of pressure suddenly
change
Low pressure sensor
Evaporator
EXV
High pressure sensor
Low pressure sensor Adjust motor speed
High pressure sensor
Low pressure sensor
Stable and Reliable Performance
-20 -10 0 10 20 30 40 50 60 70 °C
-15°C 56°C Cooling
-50 -40 -30 -20 -10 0 10 20 30 40 °C
-30°C Heating 28°C
45
4.6 Triple back-up operation technology
In units with two compressors, if one compressor fails, the other compressor can run on its own, to ensure the air
conditioning system can work stably.
In a multi-unit system, if one outdoor unit fails, the other modules provide backup so that the system can continue operating.
Running state
Standby
Failure or shutdown status Running state Emergency operation
Emergency operation
Compressor backup operation
ODU backup operation
When one fan motor fails, another motor can
still run, to ensure the stable system operation.
Fan back up operation
Running state Running state Running state Running state Error Running state
Running state
46 Priority
Priority
Priority
Priority
3
3
3
4 3
4
4
2 4
2
2
1 2
1
1
1
Rotation operation technology
Multiple protection functions
4.7
4.8
If the system is connected to multiple modules, in order to ensure the balance of compressor operation, the
automatic control of the microprocessor on the host can realize the automatic rotation operation function
between the modules, effectively extend the service life of the unit.
Multiple protection functions to ensure the safe operation of the system.
Stable and Reliable Performance
Module Rotation
Fan
anti-reverse
Phase sequence
protection
Lightning
protection
High voltage
protection
Low voltage
protection
Anti-freeze
protection
Current
protection
Harmonic
suppression
Phase
protection
Anti-electromagnetic
interference protection
Temperature
protection
Pressure
Protection
Compressor overload
protection
Motor overheating
protection
Safety grounding
protection
This function balances the operating hours across all unit
compressors, promoting even wear to significantly extend
their service life. (Applicable to dual-compressor units).
Compressor Rotation
47
The external force blows
the outdoor unit fan to
rotate in reverse. At this
time, start and stop the
rotation of the fan, and
then restart the fan motor
in a forward rotation
according to the normal
procedure, so as not to
damage the fan blades
due to excessive starting
current.
An external force causes the fan to
rotate in the opposite direction
An external force causes the fan to
rotate in the opposite direction
Start the unit and stop running Positive rotation, low starting
torque, protect the fan blade
Instant reverse rotation, torque suddenly increased,
easy to cause fan blade damage
The outdoor unit has a builtin anti-seismic module, which
has anti-seismic and antiinterference functions to ensure
the safe and stable operation of
the system in bad weather.
When the compressor casing or
motor temperature is too high,
the circuit will automatically cut
off to prevent the compressor
from overloading and cause
electrical damage, fire, etc.
When the current exceeds the
set value, the temperature will
rise, and the motor will be cut
off in time during overcurrent
operation to protect the motor
from burning due to overload.
Anti-adversity function
Lightning protection Compressor overload protection Motor overheating protection Against the wind
Often gauge
When the power cord of the outdoor unit is connected incorrectly,
the circuit will start self-protection to avoid impact and damage to
the main control board, inverter module and compressor. Ensure the
normal operation of the air conditioner, without accidental electrical
damage, fire, etc.
Automatically recognize the working voltage, when the voltage is too low, give an early warning in time, and control
the power consumption and capacity output of the multi-line system through the corresponding limit frequency.
Phase sequence protection
Low voltage recognition function
L1 L2 L3 N
48 4.9 Anticorrosion design
It adopts anti-corrosion and anti-oxidation
hydrophilic aluminum foil heat exchange fins,
which have multiple protections of lubricating
coating, hydrophilic coating and corrosionresistant coating.
Improve the protection level of the motor. The
motor shaft is made of stainless steel. During the
installation process, the motor shaft, nuts, gaskets
and exposed motor shaft are coated with anti-rust
grease, and the motor body screws and top cover
screws are coated with silicone grease.
The main board is equipped with moisture-proof glue,
the sheet metal surface of the electric control box
is treated with anti-corrosion spray, and the top of
the metal casing fan capacitor is sprayed with anticorrosion paint separately.
The nails, nuts and washers are made of stainless
steel or high anti-corrosion materials, and the
screw heads inside the machine and outside the
electric control box are coated with silicone grease
for anti-corrosion.
The surface of the sheet metal parts is phosphated
and coated with special anti-corrosion materials.
It improves the salt spray resistance and heat and
humidity resistance, and greatly improves the anticorrosion ability of the sheet metal.
Use special anti-corrosion coils. The base layer
of ordinary galvanized sheet is increased with
electrophoretic layer to achieve anti-corrosion
effect. The coil fixing screws are stainless steel
screws.
Hydrophilic aluminum fin
Motor protection upgrade
Electric control anti-corrosion Fastener
Thick sheet metal design
Special corrosion-resistant coil
Phosphating
Silicon grease
Lubrication layer Hydrophilic coating Corrosion resistant coating
Stable and Reliable Performance
49
4.10 Electronic control board SMT placement technology
The electronic control main board adopts SMT patch sealing technology to improve the anti-clutter interference,
to ensure that the main board is not affected by wind, sand, high temperature and high humidity, and to make the
main control board longer.
SMT
CPU
4.11 Anti-snow function
In the snowy weather conditions in winter, in order to prevent the snow from adversely affecting the top of the
outdoor unit fan,you can turn on anti-snow mode, the fan starts running to clear the snow to ensure the normal
operation of the unit.
50 The TMV6+ is designed for diverse application scenarios, with its
installation environment requirements carefully considered. Its appearance
and functional design incorporate user-centric details that significantly
enhance installation convenience, accelerate the process, and simplify
future maintenance.
CONVENIENT INSTALLATION
AND MAINTENANCE
Super long refrigerant
pipeline design,
flexible structure
1100 Convenient for the transportation,
installation and commissioning
Big-capacity module design, easy
installation and space saving
130Pa The highest static
pressure for outdoor
unit
15 basic modules, satisfy
all kind of requirement
Commissioning software
Auto-addressing
function
50 Emergency power-off
function for indoor unit
maintenance