OurCulture
Vision:
Tobe theworld's leadingprovider of powersolutions.
Values:
Leading in technology,prioritizing in quality.
Mission:
To drive power supply technology innovation,deliver reliable,customized precision power solutions,and empower global businesses for a better tomorrow.
Responsibility:
Commit to providing high-quality,stable power products and full-cycle services for global clients,and contributing to green and sustainable development through efficient powersolutions.
MarketRecognition
Wehave established solid partnershipswith industry leaders and delivered landmark projects that power social development.We are eager to collaborate withmore forward-thinkingpartnerstobuildabetterfuture together.
Strong Portfolio ofPartners &Users
Competitive Advantages
0 用 固 中R&D Expertise GlobalFootprint Stable Operation GlobalCompliance30+ 100+ 20000+ CE/UL
> Full-Cycle Service& Diversified ProductMatrix
One-stop R&D,manufacturing,sales and technicalsupport Rich product lineup-telecom, solar, Al server and customized industrial powersolutions
>Diversified Products&Certifications
Fullycompliantwith ISO9001,ISO45001,ISO14001 CE/ULandindustry-specific qualifications Backed by professional power design experience
》 Agile Customization&Stable Reliability
Agile tailoredservicesand globallocalizedpartnernetwork. { 2 0 , 0 0 0 + } operating systems worldwide,enhancing efficiency, stability,and sustainability.
Company Overview
Business Segments
02
MainProducts
PowerManagement Controller
OutdoorCabinets
IndoorCabinets
Subracks
SmallCellPower
EnergyStorageModule Power
Modules
Contact us
Company Overview
Hanertek Electrical Co., Ltd. is a leading power solution provider, specializing in the full-cycle R&D, manufacturing, sales,and technical services of advanced power equipment, including AC/DC rectifier, DC/DC converter, DC/AC inverter and Intelligent power management controllers.Backed by a dedicated team with 3 0 + yearsof power designexperience, Hanertek has evolved into a key player in power solutions industry.
Business Segments
01 |Telecom Power Supply
02| Server Power Supply
03| Inverter & Industrial Power Supply
ProductAdvantages
Unified Sizing Max Flexibility
High Efficiency Harsh-EnvironmentResilience
Allrectifier,PVMPPTconverter,inverter andbidirectional converter modules feature standardizeddimensions ( 1 0 7 \mathsf { W } x 4 0 . 8 \mathsf { H } x 2 7 0 \mathsf { D } \mathsf { m } \mathsf { m } ) .Realizing slot sharingandfreecombination,it supportssystembuildingfroma compact 1U subrack,enabling on-site quick configuration and seamless PV hybrid energy integration for all site requirements.
Boasts industry-leading performance with a maximum efficiency of 9 8 % (PVMPPT& bidirectional converter)and over 9 8 % for 3kW rectifiers.Operates stablyin an ultrawide temperature range of \angle 4 0 ^ { \circ } \mathsf { C } to + 7 5 ^ { \circ } C withMTBF over350,000 hours ( 2 5 ^ { \circ } { C } ) ,and isequipped with multi-level protection (lightning,overvoltage,shortcircuit,etc.) for reliable operation inharsh outdoor and indoorenvironments.
Smart Hybrid Energy Management
Massive Storage & Easy O&M
Enables integrated scheduling of PV, grid, dieselgeneratorand batteryenergysources, with intelligent peak shaving and valley filling to minimize genset start-stop cycles and boost overall site energy efficiency. Supports a full suite of communication protocols (IPv4/IPv6,SNMP,Modbus,etc.) forglobal networkingscenariosand precise on-site devicemanagement.
Equipped with 512M Flash ^ + 512M SRAM,it stores over1oomillion historical alarm and operation data with expandable external storage (USB/SD card) for complete traceability and export. Supports custom data/alarm algorithms,batch remote firmware upgrade and custom language pack import,drastically reducing O&M costsand meeting personalized globalcustomerneeds.
PowerManagementController
HC505
Introduction
Theadvanced HC5o5 controller isapowerful and cost-effective module,developed for monitoring and controlling a wide range of DC power supply systems.
The controller can be used to communicatewith small,medium and large power systems.It has a friendlyand easy-to-operate interface.
Users can operate the system via the four front buttons and the LCD display.
Users can monitor and control the system by using the SNMP via Ethernet.
Applications
Wireless communication
Broadband and networkaccess Satellite communications ground station
·3G/4G/5G base station Other telecom applications
KeyAdvantages
The standard 1 \cup ^ { \star } 2 \cup structure can save more space. RS485 or Ethernet interface for PC connection locally or remotely,and thestronger WEB server is recommended.
Front panel LCD and four buttons for on-site using without PC.
Easily configurable file upload/download via USB or PC.
Easily update software via controller, USB or PC. 2G /3G/4G function is optional.
Peak clipping and staggering power Consumption
Advanced battery management,both Lead-acid battery and Lithium battery.
Up to 112 digital outputs can be supported. Up to 147 digital inputs can be supported. Multiple LVDs control. Battery mid-point monitoring
Authority management and operator access levels protection.
More user-selectable languages.
Programmable Logic Control (PLC) function,
more flexible requirments can be supported.
Technical Specifications
General
| Power Supply | 20VDC to 70VDC |
| Temperature | Storatin:+70C |
| Humidity | Operating:≤ 95% (non-condensing) Storage:≤99% (non-condensing) |
| Cooling | Natural air flow |
| MTBF | 300,000h (T_ambient:25℃) |
| Languages | Multi languages (English as default) |
| Dimensions | 40.8x85.5x182.5mm (1U*2U) |
| Weight | 480g |
Features
| System | ·Rectifiersmanagement AC/DC overvoltage/undervoltage alarm and protection · LLVD ·Faultalarmand protection · Input& output voltage measurement Load current measurement Expansion component settings Authority management & password settings PLC setings Alarm level settings (Minor/Major/Critical/ Custom Define 1/Custom Define 2) Event log (up to 260000 records,totally) |
| Battery | Battery float/boost charging BLVD Bateryurpetreeemnt Battery testand records Battery temperature compensation |
| Rectifier | Available informationabout each rectifier Rectifier current measurement Rectifier input/output voltage measurement ·ECO Rectifier slot management Peak clipping and staggering power consumption |
| Hybrid Energy Support | ·PV Grid ·Battery ·DG · Inversion :Grid&battery priorityadjustable |
Specifications
| Standard | Expansion | |
| Analog Inputs | 1 bus voltage | Additional134via HC210 HC211and HC321 |
| 2 bat mid-points | ||
| 2 batvoltages | ||
| 2 load fuse alarms | Additional72via HC210 HC211and HC340 | |
| 2 battery currents | Additional 30 via HC210 boards | |
| 1 load current | HC211H72iaHC21310 | |
| 2 temperatures | Additional16via HC320-DI boardsand HC321 | |
| Digital Inputs | 6 | Additional 88 via HC320-DI boardsandHC321 |
| Digital Outputs | 6 | Additional104viaHC320- DOboardsand HC321 |
| LVDs | 2 | HC21nal40ntialigC210witch |
Communication Interfaces
| Hardware Interface | 5*RS485,1*Ethernet,2*CAN 1*USB |
| Protocols | HTTP/HTTPS(SSL),Modbus, IPV4/IPV6,SNMPV1/V2c/V3, FTP,Email,NP |
| Local UserInterface | 2*LEDs,4*buttons, 1.54#LCD (240X240) |
Standards Compliance
| Safety | IEC62368-1,UL62368-1,EN62368-1 |
| EMC | EN55032 ClassA (emission) EN 61000-3-12:2011 EN IEC61000-3-11:2019 EN 55035:2017+A11:2020 IEC61000-3-2C61000-3-3 IEC61000-4-2 (electrostatic discharge) IEC61000-4-3 (radiated immunity) IEC61000-4-4EFT) IEC61000-4-5 (surge immunity) IEC61000-4-6 (conducted immunity) IEC61000-4-8 |
| Environment | IEC61000-4-11 ETSI EN 300 019-2 (-1.-2,-3) ETSIEN300132-2 |
OutdoorCabinets
CT2000A2ACD01/CT2000A2HEX01
Introduction
TheOutdoor Power System isan integrated 32kW AC/DC inteligent outdoor powersolution, including rectifier modules,controllr modules,AC/DC distribution units and surge protection devices.It features a temperature regulation system for optimal component operating temp,an anti-theft mechanism for secure protection,and a dedicated battery storage space for battery banks.Alldry contacts and communication interfaces are front-accessble and operable for flexible, convenient O&M.
Application Scenario
⑨ Telecommunications&5G M SmartCity&Public Security New Energy&EVCharging ⊚ Transportation&Municipal 曲 IndustrialloT&OutdoorAutomation l _ { 2 } Power&EnergyDistribution
TechnicalSpecifications
| Project Number & Type | CT2000A2ACD01 | CT2000A2HEX01 |
| Environmental Control | DC Air-conditioner:2000W | DC Heat Exchanger: 120W/K |
| Sensor | Smoke; Water; Door opening alarm; Temperature and humidity | Smoke; Water; Door opening alarm; Temperature and humidity |
| Rack | 19inch,38U | 19inch,38U |
| Lighting | LED Lamp | LED Lamp |
| Installation method | Floor | Floor |
| Opening direction | Frontsingle door,Turn Left | Front single door, Turn Left |
| Plinth Height | 150mm | 150mm |
| Anti theft | Three-point door lock | Three-point door lock |
| Size(mm) : W*D*H | 750*750*2200(including base) | 750*750*2200(including base) |
IndoorCabinets(LargeSystem)
CR120D048A01
Introduction
The Power System is an AC/DC intelligent power system.It includes an AC cabinet, α rectifier cabinet,and a DC cabinet.Itcan house up to 2 0 x 6 \mathsf { k W } rectifier modules, 1 x 1 - 1 0 5 0 5 controller, with 7-inch or 10-inch touchscreen options available.AC input,DC output,dry contacts,and communication interfaces feature front access and front operation,making operation and maintenance flexible and convenient.The system boasts large capacity and stable performance, making itideal forcriticalapplications.
ApplicationScenario
⑨ Core Equipment Room M Large-Scale Site W Data Center
Technical Specifications
| Project Number & Type | CR120D048A01 |
| System Capacity | 120kW |
| Controller | HC505 |
| Matching Module | HPR48-6000SE |
| QuaMtity(.Max.) | 20 |
| System Input Type | 3P+N |
| AC Input Breaker | 2*400A/3PMCCB,Mechanical interlock |
| AC SPD | Typell,20kA |
| AC Output Breaker | MCCB:2*250A/3P+2*160A/3P① MCB:1*100A/3P+2*63A/3P+2*32A/3P① |
| Battey Fuse | Fuse:2*(2*1250A) |
| DC Load Fuse | 4+630A+8*500A+4*400A+4*100A② |
| DC SPD | Typell,20kA |
| DI & DO & Temp NO. | 6+6+2(expanded to 12+12+4) |
| Size(mm): W*D*H | AC Cabinet: 600*600*2000; Rectifier Cabinet: 600*600*2000; DC Cabinet: 800*600*2000; |
| Note | ①②: The capacity and quantity of AC Breakers and DC fuses can be configured as needed. |
IndoorCabinets
CR032D048C01
Introduction
The Indoor Power System is an integrated AC/DC intelligent indoor power solution, incorporating rectifier modules,controller modules,AC and DC distribution units,surge protection devices,α temperatureregulationsystem,andbatterystoragespace. Dry contactsand communication interfaces are front-accessible and front-operable, ensuring flexible and convenientoperation andmaintenance.
ApplicationScenario
⑨ Indoor
TechnicalSpecifications
| Project Number & Type | CR032D048C01 |
| System Capacity | 32kW/24kW |
| Controller | HC505 |
| Matching Module | HPR48-4000HE3/HPR48-3000HE3 |
| QuaMtity(Max.) | 8 |
| System Input Type | 1PH /3P+N |
| Input Connection | MCB:1*80A/3P+N terminal |
| Battey Breaker / Fuse | MCB:4*125A/1P |
| BLVD Configuration | MCB:3*125A/1P① +5*up to 63A/1P |
| LLVD Configuration | MCB:3*125A/1P① +4*up to 63A/1P |
| Equipment Space | 19inch rack, 18U |
| Battey Space | 19inch rack,16U |
| Opening direction | Rearti |
| Size : W(mm)*D(mm)*H(mm) | 600*600*2000 |
| Note | ①:80A/:100A MCB can be replaced |
Subracks-Rectifier
SR032D048D02 is a 19-inch subrack power systemproduced by Hanertek,featuringa compact 4U height design to meet the critical application requirementsof fiber and microwave transmission,accessdevices, and switches.The system has a maximum power/current rating of 32kW/ 600A,with AC,battery,and load terminals.AC inputand DC output cablesare front-accessible via terminals.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy Advanced managementforlead-acidandlithium-ion
S batteries
\odot Store 260,000 eventsand100,000alarms
TechnicalSpecifications/SR032D048D02
| AC Distribution | AC | DC Distribution | DC |
| Input Mode | 220VAC 3P+N | Output Voltage | -40~-58VDC,rated value:-53.5VDC |
| Input Capacity | MCB: 1×80A/3P+N terminal | Battery Breakers | 4×125A/1PMCB |
| Input Frequency | 45~ 66Hz,rated value: 50Hz/60Hz | LLVD | 3×125A/1P(80A,100A optional)+4xup to 63A/1P MCB |
| SPD | Type I,2 | BLVD | 2x125A/P(80Anal)+4xu |
| System | Environment | ||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ |
| Cabling Mode | Front inlet&outlet | Storage Temperature | -40~ +85℃ |
| Maintenance Mode | Front Maintenance | Operating Humidity | |
| Protection Level | IP20 | Altitude | 0~4000m |
| Rectifier | 8×HPR48-4000HE3 | 8×HPR48-3000HE3 | @. |
| Input Voltage | 85~300VAC,rated 220VAC | 85~300VAC,rated 220VAC | |
| Efficiency | > 97% | > 96.3% | |
| Rated Power | 4350W | 3000W | |
| Working Temperature | -40~ +75℃ | -40~ +75°℃ | |
| Controller | HC505 | ||
| Signal Input | 3Al (2 battery temp,1ambient temp.),2 RS485,Dl | ||
| Alarm Output | 6 dry contacts | ||
| Communication Port | RS485,SNMP | ||
| Display Mode | LCD | ||
Subracks-Rectifier
Thisseries comprises twoadvanced,highly flexible modular powersystems (9 kW).Theyaredesigned todeliver reliableand efficient power distribution and management solutions for a wide range of applications.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy
S Advanced managementforlead-acid and lithium-ion batteries
\odot Store 260,000 eventsand100,000alarms
TechnicalSpecifications/SR009D048A02
| Input Distribution | AC | Output Distribution | DC |
| Input Mode | 220VAC 1PH | Output Voltage | -40~-58VDC,rated value:-53.5VDC |
| Input Capacity | 1×63A/2PMCB | Battery Breakers | 2×100A/1P MCB |
| Input Frequency | 45~66Hz,rated value: 50Hz/60Hz | LLVD | 4xup to 63A/1P MCB |
| SPD | Type Il, 20kA | BLVD | 4xup to 63A/1P MCB |
| System | Environment | ||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ |
| Cabling Mode | Rear inlet&outlet | Storage Temperature | -40~+85℃ |
| Maintenance Mode | Front maintenance | Operating Humidity | |
| Protection Level | IP20 | Altitude | 0~4000m |
| Rectifier | 3×HPR48-3000HE3 |
| Input Voltage | 85~300VAC,rated220VAC |
| Efficiency | > 96.3% |
| Rated Power | 3000W |
| Working Temperature | -40~ +75℃ |
| Controller | HC505 |
| Signal Input | 3Al (2 battery temp,1 ambient temp.),2 RS485,Dl |
| Alarm Output | 6 dry contacts |
| Communication Port | RS485,SNMP |
| DisplayMode | LCD |
Subracks-Hybrid(Rectifier+Solar+lnverter)
SH016D048D01 inverter hybrid system is an integrated smart power solution using both grid and solar energy, offering ACoutput,automaticenergydistribution,seamless switching,and effcient optimization.Deliverng 16 kW(48V/300A)inacompact19-inch5Urack(witha1Ubreakerpanelforspace saving),itissuitableforbase stations,opticaltransmission,and access networks.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multiple interfaces
M Optimizinggenerators,grid power,and solarto save energy
4 Advanced managementforlead-acid and lithium-ion batteries
\odot Store260,000eventsand 100,000alarms
TechnicalSpecifications/SH016D048D01
| Input Distribution | AC | DC/Solar | Output Distribution | Rectifier/SolarConverter/Inverter | ||
| Input Mode | 220VAC 3P+N | 58~170VDC | Output Voltage | Rectifier:-40~-58VDC,rated value:-53.5VDC Solar Converter:-42~-58VDC, ratedvalue:-53.5VDC Inverter:200~300VAC,rated value: 220VAC | ||
| Input Capacity | 1×63A/4PMCB | N/A | Battery Breakers | 2×125A/1PMCB | ||
| Input Frequency | 45~ 65Hz/rated value: | 2x(63A/1PMCB + | LLVD | optioCB | ||
| SPD | Type Il,2kA | Type Il,2kA | BLVD | 1×125A/1P(80A,100A optional)+7xup to 63A/1PMCB | ||
| System | Environment | 1 | ||||
| Cooling Mode | Fansfronto-back | OperatingTemperature | -40~+75℃ | |||
| Cabling Mode | Front inlet&outlet | StorageTemperature | -40~+85℃ | |||
| Maintenance Mode | Front maintenance | Operating Humidity | ||||
| Protection Level | IP20 | Altitude | 0~4000m | ■ = | ||
| Module | 4×HPR48-4000HE3 | 2×HPS150-48-4000 | 2×HPN48-220- 3000 | ?.. | ||
| Input Voltage | 85~ 300VAC rated | N/A | N/A | |||
| Efficiency | > 97% | >98% | >94% | |||
| Rated Power | 4350W | 4000W | 3000VA | |||
| WorkingTemperature | -40~+75℃ | -40~+75C | -20~+75°C | |||
| Controller | HC505 | |||||
| Signal Input | 3Al (2 battery temp,1ambient temp.),2 RS485,Dl | |||||
| Alarm Output | 6 dry contacts | |||||
| RS485,SNMP | ||||||
| Communication Port | LCD | |||||
| Display Mode | ||||||
Subracks-Rectifier
This series includes one high-performance,scalable modular DC powersystem (SR016D048A02,16 kW/12 kW), engineredtomeet therigorous demandsof aplications requiring unmatched powersupplyreliability,industryleading power density,and advanced intelligent management.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy
S Advanced managementforlead-acid and lithium-ion batteries
\odot Store 260,000 eventsand100,000alarms
TechnicalSpecifications/SR016D048A02
| Input Distribution | AC | Output Distribution | DC |
| Input Mode | 220VAC 1PH/3P+N | Output Voltage | -40~-58VDC,rated value:-53.5VDC |
| Input Capacity | Terminal | Battery Breakers | 2×125A/1P MCB |
| Input Frequency | 45~ 66Hz,rated value: 50Hz/60Hz | LLVD | 2×125A/1P(80A,100A optional)+6xup to 63A/1PMCB |
| SPD | N/A | BLVD | 2x125A/1P(80A,100AMCional)+6xup |
| System | Environment | ||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ |
| Cabling Mode | Top inlet &outlet | Storage Temperature | -40~ +85℃ |
| Maintenance Mode | Front maintenance | Operating Humidity | |
| Protection Level | IP20 | Altitude | 0~ 4000m |
| Rectifier | 4×HPR48-4000HE3 | 4×HPR48-3000HE3 |
| Input Voltage | 85~300VAC,rated220VAC | 85~300VAC,rated220VAC |
| Efficiency | > 97% | > 96.3% |
| Rated Power | 4350W | 3000W |
| TeWorkiture | -40~+75℃ | -40~ +75°℃ |
| Controller | HC505 |
| Signal Input | 3Al (2 battery temp,1ambient temp.),2 RS485,Dl |
| AlarmOutput | 6 dry contacts |
| Communication | RS485,SNMP |
| DisplayMode | LCD |
Subracks-Rectifier
Thisseries includes two high-performance,scalable modular DC power systems (16kW/12kW),engineered to meettherigorousdemandsof applicationsrequiringunmatched power supplyreliability,industry-leading power density,and advanced intelligent management.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy
S Advanced managementforlead-acid and lithium-ion batteries
\odot Store 260,000 eventsand100,000alarms
TechnicalSpecifications/SR016D048B01
| AC Distribution | AC | Output Distribution | DC |
| Input Mode | 220VAC 3P+N | Output Voltage | -40 ~-58VDC,rated value:-53.5VDC |
| Input Capacity | 1×63A/4P MCB | Battery Breakers | 2×125A/1PMCB |
| Input Frequency | 45~66Hz,rated value: 50Hz/60Hz | LLVD | 2×125A/1P(80A,100A optional)+6xup to 63A/1PMCB |
| SPD | Type II,2kA | BLVD | 2×125A/1P(80A,100A optional)+6xup to 63A/1PMCB |
| System | Environment | ||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ |
| Cabling Mode | Top inlet&outlet | Storage Temperature | -40~ +85°℃ |
| Maintenance Mode | Frontmaintenance | Operating Humidity | |
| Protection Level | IP20 | Altitude | 0~ 4000m |
| Rectifier | 4×HPR48-4000HE3 | 4×HPR48-3000HE3 |
| Input Voltage | 85~300VAC,rated 220VAC | 85~300VAC,rated 220VAC |
| Efficiency | > 97% | > 96.3% |
| Rated Power | 4350W | 3000W |
| Working Temperature | -40~ +75°℃ | -40~ +75°℃ |
| Controller | HC505 |
| Signal Input | 3Al (2 battery temp,1ambient temp.),2 RS485, Dl |
| Alarm Output | 6drycontacts |
| Communication Port | RS485,SNMP |
| DisplayMode | LCD |
Subracks-Rectifier
Thisseries includes two high-performance,scalable modularDC power systems (32kW/24kW),engineered to meet the rigorous demands of applications requiring unmatched power supplyreliabilty,industry-leading power density,and advanced intelligent management.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy
S Advanced managementforlead-acid and lithium-ion batteries
\odot Store 260,000 eventsand100,000alarms
TechnicalSpecifications/SR016D048B02
| Input Distribution | AC | Output Distribution | DC |
| Input Mode | 220VAC 3P+N | Output Voltage | -40 ~-58VDC,rated value:-53.5VDC |
| Input Capacity | 1×80A/3P MCB + N terminal | Battery Breakers | 4×125A/1P MCB |
| Input Frequency | 45~66Hz,rated value:50Hz/60Hz | LLVD | 3×125A/1P(80A,100A optional)+4xup to 63A/1PMCB |
| SPD | Type II,2kA | BLVD | 3×125A/1P(80A,100A optional)+5xup to 63A/1PMCB |
| System | Environment | ||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ |
| Cabling Mode | Top inlet&outlet | Storage Temperature | -40~ +85°℃ |
| Maintenance Mode | Frontmaintenance | Operating Humidity | |
| Protection Level | IP20 | Altitude | 0~ 4000m |
| Rectifier | 8×HPR48-4000HE3 | 8×HPR48-3000HE3 |
| Input Voltage | 85~300VAC,rated 220VAC | 85~300VAC,rated 220VAC |
| Efficiency | > 97% | > 96.3% |
| Rated Power | 4350W | 3000W |
| Working Temperature | -40~ +75°℃ | -40~ +75°℃ |
| Controller | HC505 |
| Signal Input | 3Al(2 battery temp,1ambient temp.),2 RS485,Dl |
| AlarmOutput | 6drycontacts |
| Communication Port | RS485,SNMP |
| DisplayMode | LCD |
Subracks-Rectifier
The SR003D048A01 isa 3 ~ \mathsf { k W } power system solution engineered for universal application requirements, prioritizing stabilityand reliability.Its core is builtaroundthe HC505controlersupportingamaximumof three HPR48-1000HE3 powermodules.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy
S Advanced managementforlead-acid and lithium-ion batteries
\odot Store 260,000 eventsand100,000alarms
TechnicalSpecifications/SR003D048A01
| Input Distribution | AC | Output Distribution | DC |
| Input Mode | 220VAC 1PH | Output Voltage | -40~-58VDC,rated value:-53.5VDC |
| Input Capacity | Terminal(1×50A) | Battery Breakers | 2×32A/1PN MCB |
| Input Frequency | 45~ 66Hz,rated value: 50Hz/60Hz | LLVD | 2×32A/1PN MCB |
| SPD | N/A | BLVD | 2×10A/1PN MCB |
| System | Environment | ||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ |
| Cabling Mode | Rear inlet and front outlet | Storage Temperature | -40~+85℃ |
| Maintenance Mode | Front maintenance | Operating Humidity | |
| Protection Level | IP20 | Altitude | 0~4000m |
| Rectifier | 3×HPR48-1000HE3 |
| Input Voltage | 85~300VAC,rated220VAC |
| Efficiency | > 95.5% |
| RatedPower | 1000W |
| Working Temperature | -40~+75°℃ |
| Controller | HC505 |
| Signal Input | 3AI(2battery temp,1ambient temp.),2 RS485,DI |
| Alarm Output | 6drycontacts |
| Communication Port | RS485,SNP |
| DisplayMode | LCD |
Subracks-Rectifier
The SR003D048A02 is a 3 ~ \mathsf { k W } power system that offers enhanced flexibility and scalability in its electrical configuration.It shares acommon core platformwiththestandard version,including thecontroler,compatible modules,and system capacity.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy
S Advanced managementforlead-acid and lithium-ion batteries
\odot Store 260,000eventsand100,000 alarms
Technical Specifications/SR003D048A02(Configurable)
| Input Distribution | AC | Output Distribution | DC |
| Input Mode | 220VAC 1PH | Output Voltage | -40~-58VDC,rated value:-53.5VDC |
| Input Capacity | Terminal(1×50A) | Battery Breakers | 1×50A+1×32A/1PNMCB |
| Input Frequency | 45~66Hz,rated value: 50Hz/60Hz | LLVD | N/A |
| SPD | N/A | BLVD | 2×10A/1PN+2×32A/1PNMCB |
| System | Environment | ||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ |
| Cabling Mode | Rear inlet and front outlet | Storage Temperature | -40~+85℃ |
| Maintenance Mode | Front maintenance | Operating Humidity | |
| Protection Level | IP20 | Altitude | 0~4000m |
| Rectifier | 3×HPR48-1000HE3 |
| Input Voltage | 85~300VAC,rated220VAC |
| Efficiency | > 95.5% |
| RatedPower | 1000W |
| Working Temperature | -40~+75℃ |
| Controller | HC505 |
| Signal Input | 3Al (2 battery temp,1ambient temp.),2 RS485,DI |
| Alarm Output | 6drycontacts |
| Communication | RS485,SNMP |
| DisplayMode | LCD |
Subracks-Hybrid(Rectifier+Solar)
SH016D048C01 isan inteligent telecom power solution that integrates both grid and solar inputs.It features a compact 19-inch 5U rack design (with a 1U breaker panelfor space saving)with a maximum output power of 16 + 1 6 kW (48V/300A).The system supports automatic energy management and seamless switching,with frontaccess wiring foreasy installationand maintenance.Itis idealfor basestations,optical transmission,andaccess network applications.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy
S Advanced managementforlead-acidand lithium-ion batteries
\odot Store 260,000eventsand100,000 alarms
TechnicalSpecifications/SH016D048C01
| Input Distribution | AC | DC/Solar | Output Distribution | Rectifier/SolarConverter | ||
| Input Mode | 220VAC 3P+N | 58~170VDC | Output Voltage | Rectifier:-40~-58VDC,rated SolarConvet35V58V ratedvalue:-53.5VDC | ||
| Input Capacity | 1x63A/4PMCB | N/A | BatteryBreakers | 2×125A/1PMCB | ||
| Input Frequency | 45~66Hzrated vale: | 4x(63A/1P MCB + | LLVD | opti1PMCB | ||
| SPD | Type I,20kA | Type I, | BLVD | 1×125A/1P(80A,100A optional)+7xup to 63A/1P MCB | ||
| System | Environment | |||||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ | |||
| Cabling Mode | Front inlet &outlet | StorageTemperature | -40~+85°℃ | |||
| Maintenance Mode | Front maintenance | Operating Humidity | ||||
| Protection Level | IP20 | Altitude | 0~4000m | - | ||
| Module | 4×HPR48-4000HE3 | 4×HPS150-48-4000 | ||||
| Input Voltage | 85~300VAC,rated220VAC | N/A | ||||
| Efficiency | > 97% | > 98% | ||||
| Rated Power | 4350W | 4000W | ||||
| Working Temperature | -40~ +75℃ | -40~+75°℃C | ||||
| Controller | HC505 | |||||
| Signal Input | 3Al (2 battery temp,1ambient temp.),2 RS485,Dl | |||||
| Alarm Output | 6 dry contacts | |||||
| Communication Port | RS485, SNMP | |||||
| Display Mode | LCD | |||||
Subracks-Hybrid(Rectifier+Solar)
SH032D048A01 is an intelligent telecom power solution that integrates both grid and solarinputs.It features a compact19-inch 8U rack design with a maximum output power of 32 kW(48V/600 A).The system supports automatic energy management and seamless switching,with front-access wiring for easy installation and maintenance.Itisidealforbase stations,opticaltransmission,and access network applications.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy Advanced managementforlead-acidandlithium-ion
S batteries
\odot Store 260,000eventsand100,000 alarms
TechnicalSpecifications/SH032D048A01
| Input Distribution | AC | DC/Solar | Output Distribution | Rectifier/SolarConverter | ||
| Input Mode | 220VAC 3P+N | 58~170VDC | Output Voltage | Rectifier:-40~-58VDC,rated value:-53.5VDC SolarConverter:-42~-58VDC, rated value:-53.5VDC | ||
| Input Capacity | 1x80A/3P MCB + N | N/A | Battery Breakers | 4×125A/1PMCB | ||
| Input Frequency | 45~ 50Hzratd value | 4x(63A/1P MCB + | LLVD | opti | ||
| SPD | Type Il,20kA | Type Il,2kA | BLVD | optnB | ||
| System | Environment | |||||
| Cooling Mode | Fans(fronti back | Operating Temperature | -40~+75℃ | |||
| Cabling Mode | Front inlet &outlet | StorageTemperature | -40~+85℃ | |||
| Maintenance Mode | Front maintenance | Operating Humidity | ||||
| Protection Level | IP20 | Altitude | 0~4000m | = | ||
| Module | 8×HPR48-4000HE3 | 4xHPS150-48-4000 | ||||
| Input Voltage | 85~300VAC,rated 220VAC | N/A | ||||
| Efficiency | > 97% | > 98% | ||||
| Rated Power | 4350W | 4000W | ||||
| Working Temperature | -40~ +75℃ | -40~ +75℃ | ||||
| Controller | HC505 | |||||
| Signal Input | 3AI(2 battery temp,1ambient temp.),2 RS485, Dl | |||||
| Alarm Output | 6 dry contacts | |||||
| Communication Port | RS485,SNMP | |||||
| Display Mode | LCD | |||||
Subracks-Hybrid(Rectifier+lnverter)
SH016D048EO1rectifier-inverter hybrid system is an integrated smartpowersolutiondelivering both DCand AC output,featuring automaticenergymanagement,seamlessswitching,andeficientoperation.With16kW(48V/ 300A)all housedinacompact19-inch4Urack(witha1Ubreakerpanelforspacesaving),itis idealfortelecom base stations, opticaltransmission,and access networks.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy Advanced managementforlead-acidandlithium-ion
S batteries
\odot Store 260,000 eventsand100,000alarms
TechnicalSpecifications/SH016D048E01
| InputDistribution | AC | Output Distribution | Rectifier/Inverter | |||
| Input Mode | 220VAC 3P+N | 1 | Output Voltage | Rectifier:-40~-58VDC,rated Inverte:003VCtd value: 220VAC | ||
| Input Capacity | 1×63A/4PMCB | / | Battery Breakers | 2×125A/1PMCB | ||
| Input Frequency | 45~ 650Hzratedvalue: | 1 | LLVD | opt | ||
| SPD | Type I,2kA | 1 | BLVD | optio | ||
| System | Environment | |||||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ | |||
| Cabling Mode | Front inlet&outlet | StorageTemperature | -40~+85°℃ | |||
| Maintenance Mode | Front maintenance | Operating Humidity | = | |||
| Protection Level | IP20 | Altitude | 0~4000m | |||
| Module | 4×HPR48-4000HE3 | 4×HPN48-220-3000 | ||||
| Input Voltage | 85~300VAC,rated 220VAC | N/A | @. | |||
| Efficiency | > 97% | > 94% | ||||
| Rated Power | 4350W | 3000W | ||||
| Working Temperature | -40~+75℃ | -20~+75℃ | ||||
| Controller | HC505 | ? | ||||
| Signal Input | 3Al(2 battery temp,1ambient temp.),2 RS485, Dl | |||||
| Alarm Output | 6 dry contacts | |||||
| Communication Port | RS485, SNMP | |||||
| Display Mode | LCD | |||||
Subracks-SolarMPPT
SS016D048B01standalone solar PVsystem is designed for existing base station sites,enabling solar overlay to reduce electricitycosts.Itfeatures acompact19-inch 3Urack design.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy
S Advanced managementforlead-acid and lithium-ion batteries
\odot Store 260,000eventsand100,000 alarms
| Input Distribution | DC/Solar | Output Distribution | SolarConverter |
| Input Mode | 58~170VDC | Output Voltage | -40 ~-58VDC,rated value:-53.5VDC |
| Input Connection | 4×(63A/1P MCB + terminal) | Output Connection | 1xNegativeterminal +1ositive |
| Input Frequency | N/A | LLVD | N/A |
| SPD | Type Il,20kA | BLVD | N/A |
| System | Environment | ||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ |
| Cabling Mode | Rear inletand front outlet | Storage Temperature | -40~+85℃ |
| Maintenance Mode | Front maintenance | Operating Humidity | |
| Protection Level | IP20 | Altitude | 0~ 4000m |
| Module | 4×HPS150-48-4000 |
| Input Voltage | N/A |
| Efficiency | > 98% |
| RatedPower | 4000W |
| Working Temperature | -40~+75°℃ |
| Controller | HC505 |
| Signal Input | 3Al(2 battery temp,1ambient temp.),2 S485,Dl |
| Alarm Output | 6drycontacts |
| Communication Port | RS485,SNMP |
| Display Mode | LCD |
Subracks-Inverter
SV012A220B01 standalone inverter system is designed for existing base station sites,providing additional AC output.It features a compact19-inch 2U rack design.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy
S Advanced managementforlead-acid and lithium-ion batteries
\odot Store 260,000 eventsand100,000alarms
TechnicalSpecifications/SV012A220B01
| Input Distribution | DC | Output Distribution | AC |
| Input Mode | 85~400VDC | Output Voltage | 200~300vAC,rated value: 220VAC |
| Input Connection | 1×Negative terminal + 1×Positive terminal | Output Connection | 2×32A/1PN MCB |
| Input Frequency | N/A | LLVD | N/A |
| SPD | Type I,20kA | BLVD | N/A |
| System | Environment | ||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ |
| Cabling Mode | Rear inlet and front outlet | Storage Temperature | -40~ +85°℃ |
| Maintenance Mode | Front maintenance | Operating Humidity | |
| Protection Level | IP20 | Altitude | 0~ 4000m |
| Module | 4xHPN48-220-3000 |
| Input Voltage | 48V |
| Efficiency | > 94% |
| Rated Power | 3000W |
| Working Temperature | -40~ +75°C |
| Controller | HC505 |
| Signal Input | 3Al (2 battery temp,1ambient temp.),2 RS485,Dl |
| Alarm Output | 6drycontacts |
| Communication Port | RS485,SNMP |
| Display Mode | LCD |
Subracks-Inverter
The1RU 4kVAinverter systemis a DC-to-AC inverterdesigned fortelecom power applications. The subrack supports grid/battery priority mode selection. WhenonebranchoftheACpowersupplyfails,thebuilt-inswitchenablesarapidswitchovertotheotherbranchto preventload powerinterruption,providing additionalbackup foruninterruptiblepowersupply.
KeyFeatures
⑨ Controllerwith ^ { 9 + } protocolsand multipleinterfaces Optimizinggenerators,grid power,and solarto save
M energy Advanced managementforlead-acidandlithium-ion
S batteries
\odot Store 260,000 eventsand100,000alarms
TechnicalSpecifications/SV004A120B01
| Input Distribution | DC | Output Distribution | AC |
| Input Mode | 53.5VDC | Output Voltage | 200~300vAC,rated value: 220VAC |
| Input Connection | 1xNegative terminal + 1xPositive terminal | Output Connection | 2×32A/1PN MCB |
| Input Frequency | N/A | LLVD | N/A |
| SPD | Type I,20kA | BLVD | N/A |
| System | Environment | ||
| Cooling Mode | Fans(front-to-back ventilation) | Operating Temperature | -40~+75℃ |
| Cabling Mode | Rear inletand frontoutlet | StorageTemperature | -40~+85℃ |
| Maintenance Mode | Front maintenance | Operating Humidity | |
| Protection Level | IP20 | Altitude | 0~ 4000m |
| Module | 2xHPN48-120-2000 | 1×By-Pass Module | ?: |
| Input Voltage | N/A | 120/220vAC configurable | |
| Efficiency | > 94% | N/A | |
| Rated Power | 4000VA | 7.2/12kVA configurable | |
| Working Temperature | -40~+75℃ | -40~ +75℃ | |
| Controller | HC505 | ||
| Signal Input | 3Al (2 battery temp,1ambient temp.),2 RS485,Dl | ||
| Alarm Output | 6 dry contacts | ||
| Communication Port | RS485, SNMP | ||
| Display Mode | LCD | ||
Subracks-DCPDU
The DC Distribution Unit (DCDU)provides tworeliable DCoutputsfor telecomand networkequipment, ensuring safe,organized,andeffcientpowermanagement.Itfeaturesacompact19-inch1Urackdesign(witha1Ubreaker panelfor space saving),idealfor existing base station installations.
Application Scenario
⑥ PowersupplyforLTEin-building solutions MPowersupplyforFTTxbroadband multi-solutions 乡 Powersupplyformacrostation and outdoorcabinet
TechnicalSpecifications
| Module | UH012D048D01 |
| System Capacity | 250A |
| Input Connection | 1×Negative terminal + 1×Positive terminal |
| Output Connection | 18xup to 63A/1PN |
Subracks-DCPDU
The DCDistribution Unit (DCDU)provides two reliable DCoutputs for telecomand networkequipment,ensuring safe,organized,andeffcientpowermanagement.Itfeaturesacompact19-inch1Urackdesign(witha1Ubredker panelforspace saving),ideal forexisting base station installations.
ApplicationScenario
⑨ PowersupplyforLTEin-building solutions MPowersupplyforFTTxbroadband multi-solutions 4 Powersupplyformacro station andoutdoorcabinet
Technical Specifications
| Module | UH012D048D02 |
| System Capacity | 250A |
| Input Connection | 2×125A/1PN MCB |
| Output Connection | Branch 1: 8xup to 63A/1PN Branch 2: 8xup to 63A/1PN |
SmallCellPower
Introduction
* Integrated All-in-One Design
Combines rectification,power distribution,battery,monitoring,and wireless communication into acompactstructure,enabling intelligentmanagementand control.
* High Efficiency,EnergySavings&Reliability
Utilizes an efficient topological architecture for high conversion efficiency and significantly reduced energy consumption.The aluminum casing offers excellent heat dissipation,ensuring stable performanceinwide-temperature,humid,dusty,andotherharshoutdoorenvironments.
* Flexible Installation&ComprehensiveProtection
Supports wall/pole mounting for rapid deployment on wals,rooftops,and various other scenarios.With an IP65 protection rating,it resists sunlight,rain,andfreezing conditions.
* ReduceTCO&Empower5G
Lowers electricity expenses,simplifies maintenance,and provides α reliable and economical power solution for5G network construc-tion.
ApplicationScenario
⑨ 5G/4G Small Cell Deployment M FTTH/FTTRAccess Power IndoorDAS Power Supply ⊚ OutdoorCompact Cabinets&Edge Nodes 曲 SmartPoles&loTTerminals [ \limits _ { a } RRU/AAU Remote Power
TechnicalSpecifications
Basic Parameters
| OperatingAmbientTemperature | -40℃~+55℃ |
| CoolingMethod:Natural Convection | Natural Convection |
| Relative Humidity | |
| Noise Level | |
| Dimensions (WXH×D) | 305*400*70mm |
| Net Weight | ≤8.5KG |
| Installation: | Wall-mounted,Pole-mounted,Angle Steel Tower,Flag-mounted,Flat-mounted, etc. |
| Ingress Protection (IP) Rating | IP65 |
AC Input
| Input Voltage Range | AC85~300V,220Vac |
| Input Frequency | 45~55Hz |
| Maximum Input Current | 20.4Ax1/40A×1 |
| Power Factor (PF) | ≥0.99 |
| Surge Protection Level | 20KA |
DC Output
| Rated Output Voltage | DC48V |
| Rated OutputPower | 3000W/6000W |
| Load Output Circuits | 40Ax3/40A×7 |
| Battery Circuit | 60Ax1/125A×2 |
| Peak Efficiency | 97.50% |
Communication & Monitoring
| Communication Methods | SerialPort,Bluetooth MobileApp,Remote MonitoringPlatform |
| Dry Contact: | 3-channelAlarm Dry Contact Output |
| Communication Interface | RS485,CAN |
| Wireless Communication | 4G Network,Bluetooth |
DC Output
| Battery Type | LifePO,(Lithium Iron Phosphate) |
| RatedBatteryVoltage | DC 48V |
| Battery Capacity | 48V/20Ah or 48V/50Ah |
| Battery ManagementSystem (BMS) | CAN Bus |
| Alarms&Protection | Over-voltage,Under-voltage, Short Circuit, Overload, Reverse Polarity, Over-temperature,Low-temperature Protection |
EnergyStorageModule
HBL4850A02
Introduction
This product can be widely usedin harsh environmentalscenarios such as outdooriron tower and light pole stations,indoor weak current wells,and micro stations,serving as a backup power supply for communication equipment such as RRU and AAU at the access side of the communication network.It supports wall-mounted,pole-mounted,angle-steel-tower-mounted, flag-mounted,flat-mounted,and floor-mounted installation methods to meet various deploymentrequirements.
Key Features
ApplicationScenario
Easy Operationand Maintenance ⊚ Long Life Span 曲IntelligentProtection [ / { 7 } { 4 } Good EnvironmentalAdaptability ⊚ PowersupplyforLTEin-building solutions MPowersupplyforFTTxbroadband multi-solutions 乡 Powersupplyformacrostation and outdoorcabinet
TechnicalSpecifications
| BasicPhysicalParameters | |
| Connection Method | 1P15S |
| Dimensions (WxH×D) | 291×177×425 mm |
| Weight | 28 kg |
| Installation Method | l |
| Protection & Functional Features& Functional Features | Voltage,current and temperature intelligent protection |
| Electrical Core Parameters | |
| Rated Voltage | 48V DC |
| Rated Capacity | 50Ah |
| Rated Energy | 2400Wh |
| Working Voltage Range | 40.5V - 53.3V DC |
| Charging Current | 0~50A |
| Discharging Current | 0~50A |
| EnvironmentalAdaptability Parameters | |
| Operating Temperature (Charging) | 0°C~60°℃ |
| Operating Temperature (Discharging) | -20°℃~60°℃ |
| Storage Temperature | 0°C~40°℃ |
| Environmental Adaptability | |
| Battery Performance Parameters | |
| Self-discharging Rate | Test condition: -30oC/3 months (specific value not specified) |
| Cycle Life | 1200cycles@80%DOD,0.5Ccharge/discharge,25C |
| BMS Function & Parameters | |
| Integrated Design Feature | Integrated BMS; supprsdaterfulf-management ofSOC,SO |
| Communication Interface | RS485/CAN |
| Signal Acquisition Function | Acquiressinglecell voltage,externalbusbar voltage,battery module total voltage,charging/dischargingcurrent,cellsurface temperature,BMS board temperature (for each series) |
| Battery Cell Equalization Function | Passiee |
| Charging Current Limit Function | Non-current limiting / Active current limiting (optional) |
| Acquisition Accuracy | Currentdetection acuracy: ±2% (votageacquisitionacuracy |
| Historical Storage Function | 500 historical records with independent storage space; records include battery voltage,current,ambient temperature,SOC,OH, cycle times,cumulative discharge capacity,etc. |
PowerModules
| Model | HPR48-1000HE3 | HPR48-3000HE3 | HPR48-3000SE3 | HPR48-4000HE3 |
| g | @..T | |||
| Remark | Rectifier | Rectifier | Rectifier | Rectifier |
| Max Power | 1000W | 3000W | 3000W | 4350W |
| Size | 1U*1.25U*253.5 mm | 1U*2.5U*270 mm | 1U*2.5U*270 mm | 1U*2.5U*270 mm |
| Working mode | ||||
| Rated Vout | 53.5VDC | 53.5VDC | 53.5VDC | 53.5VDC |
| Range Vout/ Vout range | 42-58VDC | 40-58VDC | 40-58VDC | 40-58VDC |
| Max Efficiency | 95.5% | 96.3% | 98.0% | 97% |
| Vin(Ac) | 85-300VAC | 85-300VAC | 85-300VAC | |
| Vin(Ac)@ Full Load | 154-300VAC | 176-300VAC | 85-300VAC | 176-300VAC |
| Vin(Dc) | 85-400VDC | 85-400VDC | 85-400VDC | |
| Rated Vin | ||||
| Vin(Dc)@ Full Load | ||||
| Ta(℃) | -40~+75 | -40~+75 | -40~+75 | -40~+75 |
| Ta@ Full load(℃) | -40~+55 | -40~+55 | -40~+85 | -40~+55 |
PowerModules
| Model | HPR48-6000SE | HPS150-48-4000 HPN48-220-3000 | HPB48-48-5800 | ||
| Remark | Rectifier | Solar | Inverter | BidirectionalConverter | |
| MaxPower | 6000W | 4013W | 3000VA | 5760W | 5830W |
| Size | 1U*2U*418 | 1U*2.5U*270mm | 1U*2.5U*270mm | 1U*2.5U*270 | |
| Workingmode | mm | mm Charging | Discharging | ||
| RatedVout | 53.5VDC | 53.5VDC | 220VAC | 48VDC | 53.5VDC |
| Range Vout/ Vout range | 42~58VDC | 42-58VDC | 200-230VAC | 43.2- 57.6VDC | 43.2-58VDC |
| Max Efficiency | 97.0% | 98.0% | 94.0% | 98% | 98% |
| Vin(Ac) | 208~530VAC | / | 1 | ||
| Vin(Ac)@ Full Load | (3phY) 305-530V | / | / | ||
| Vin(Dc) | 58-170VDC | 42-58VDC | 43.2-58VDC | 43.2-57.6VDC | |
| Rated Vin | 53.5VDC | 48VDC | |||
| Vin(Dc)@ Full Load | 72-150VDC | 46-58VDC | 53-58VDC | 48-57.6VDC | |
| Ta(℃) | -40~+75 | -40~+75 | -20~+75 | -40~+75 | |
| Ta@ Full load(℃) | -40~+50 | -40~+55 | -20~+55 | -20~+55 | |
HPR48-1000HE3
Introduction
HPR48-10ooHE3 is a digital rectifier with outstanding reliability,efficiencyand power density. Itisspecially designed for telecom,networkaccess,servicesand so on.
Features
Highefficiencyand high powerdensity 9 5 . 5 % efficiencyand 28.64W/in power density.
Digital control
Digitalprimaryandsecondarycontrol,realizeexcellent monitoring and regulation.
Highreliabilitydesign
One fan front-to-back air flow with latest thermal solution and experienced design.
Excellent EMC performance
Lower interference and excellent susceptibility give module better compatibility.
Global approvals
MeetCE,ULandTUVstandard.
Input
| Voltage | 85~300VAC(Norminal 220VAC) |
| Frequency | 45Hz~66Hz |
| Input Current | |
| PowerFactor | >0.99 |
| THDi |
Output
| Voltage | 42~58V DC (Nominal 53.5V DC) |
| Power | 1000W |
| Maximum Current | 21Aat48VDC |
| Static Voltage Regulation | |
| Dynamic Volgulation | regulfor 1tim~9%0md, |
| Ripple | |
| Psophometric | |
| Currint | |
| Hold up time | >10ms |
| Startup time | 3~8S |
| Efficiency | 95.5% |
Other Specifications
Diagrams
| Operating temp | -40℃~+75℃ |
| Storage temp | -40℃~+85℃ |
| Relative humidity | |
| Altitude | 4000m |
| IP level | IP20 |
| Input protection | 1KAlightning protection |
| Output protection | 59Vdc Overvoltage shutdown Short circuit proof Output fuse |
| Isolation | 3.0KVAC-input and output 1.5KVAC-input and earth 0.5KVAC-output and earth |
| Cooling | One fan (front to back airflow) |
| Fan speed | Temperature and output current regulated |
| MTBF | >300,0o0 hours (T_ambient:25℃) Telcordia SR-332 Issue 1 |
| Acoustic noise | ≤50dB at 220VAC input and full load (T_ambient |
| Dimensions | 55W×41.6 H× 253.5D (mm) |
| Weight | 1.0Kg |
Applicable Standards
| Safety | IEC62368-1,UL62368-1,EN62368-1 |
| EMC | EN55032 Class A (emission) EN 61000-3-12:2011 EN IEC 61000-3-11:2019 EN55035:2017+A11:2020 IEC61000-3-2C61000-3-3 IEC61000-4-2(electrostatic discharge) IEC61000-4-3 (radiated immunity) IEC61000-4-4EFT) IEC61000-4-5 (surge immunity) IEC61000-4-6 (conducted immunity) IEC61000-4-8 |
| Environment | IEC61000-4-11 ETSI EN300 019-2 (-1.-2,-3) ETSIEN300132-2 |
HPR48-3000HE3
Introduction
HPR48-3000HE3 is a digital rectifier module. It is speciallydesigned fortelecom,network access and data center applications and so on.It can work withoutstandingreliability,efficiencyand power density.
Features
High efficiency and high power density 9 6 . 3 % efficiencyand41.7W/in²powerdensity.
Digital control
Digital primary and secondary control,realizing excellent monitoring and regulation.
High reliability design
One fan front-to-back airflow with latest thermal solution and experienced design.
Disconnect mains when hazardous input
SPIll48/30ooHE disconnects mains to protect itself when it can not sustain the input voltage. ExcellentEMC performance
Lower interference and excellent susceptibility give the module a better compatibility.
Global approvals
Meet CE,ULand TUV standard.
AC Input
| Voltage | 85-300VAC (Nominal: 220VAC) |
| Frequency | 45-66Hz |
| Input Current | |
| PowerFactor | >0.99 |
| THDi |
DC Input
| Voltage | 85-400VDC (Nominal: 220VDC) |
| Input Current |
Output
| Voltage | 40-58VDC (Nominal53.5VDC) |
| Power | 3000W |
| Max.Current | 62.5Aat48VDC |
| Static Voltage Regulation | |
| Dynamic Voltage Regulation | |
| Ripple | |
| Psophometric | |
| Current Sharing | |
| Holdup Time | >10ms |
| Startup Time | 3-8s |
Other Specifications
| Operating Temp. | -40℃~75℃ |
| Storage Temp. | -40℃~85℃ |
| Relative Humidity | |
| Altitude | 4000m |
| IP Level | IP20 |
| Input Protection | 5KA lightningprotection |
| Output Protection | Overvoltage shutdown,short circuit protection,output fuse protection. |
| Isolation | 4242VDC-input and output 2121VDC-input and earth |
| Cooling | 707VDC-outputandearth One fan (front-to-back airflow) |
| Fan Speed | Teguparature and output current |
| MTBF | >3500da R-s(T_ambient: 25C) |
| Acoustic Noise | ≤55dB at 220VAC input and full load (T_ambient: |
| Dimensions | 107Wx40.8Hx270D (mm) |
| Weight | 1.9Kg |
Applicable Standards
| Safety | IEC62368-1,UL62368-1,EN62368-1 |
| EMC | EN55032 ClassA (emission) EN 61000-3-12:2011 EN IEC 61000-3-11:2019 EN55035:2017+A11:2020 IEC61000-3-2C61000-3-3 IEC61000-4-2 (electrostatic discharge) IEC61000-4-3(radiated immunity) IEC61000-4-4EFT) IEC61000-4-5 (surge immunity) IEC61000-4-6 (conducted immunity) IEC61000-4-8 |
| Environment | ETSI EN 300 019-2(-1.-2,-3) ETSI EN300 132-2 |
Diagrams
HPR48-3000SE3
Introduction
HPR48-300oSE3 is a digital rectifier module.Itis specially designed for telecom,network access and data center applications and so on.It can work with outstanding reliability,efficiency and power density.
Features
Super high efficiencyand high power density 9 8 % efficiency and 41.7W/in³ power density.
Digitalcontrol
Digital primary and secondary control,realizing excellent monitoringand regulation.
· High reliability design
One fan front-to-back airflow with latest thermal solution and experienced design.
Disconnectmainswhen hazardous input
HPR48-300oSE3 disconnects mains to protect itself when it can not sustain the input voltage.
ExcellentEMCperformance
Lower interference and excellent susceptibility give the module a better compatibility.
Global approvals
Meet CE,ULandTUVstandard.
AC Input
| Voltage | 85-300VAC (Nominal: 220VAC) |
| Frequency | 45-66Hz |
| Input Current | |
| Power Factor | >0.99 |
| THDi |
DC Input
| Voltage | 85-400VDC (Nominal: 220VDC) |
| Input Current |
Output
| Voltage | 40-58VDC (Nominal 53.5VDC) |
| Power | 3000W |
| Max.Current | 62.5Aat48VDC |
| Static Voltage Regulation | |
| DynamicVoltage Regulation | |
| Ripple | |
| Psophometric | |
| Current Sharing | |
| Holdup Time | >10ms |
| Startup Time | 3-8s |
| Efficiency | 98% |
Other Specifications
| Operating Temp. | -40℃~75℃ |
| Storage Temp. | -40℃~85℃ |
| Relative Humidity | |
| Altitude | 4000m |
| IP Level | IP20 |
| Input Protection | 5KA lightning protection |
| Output Protection | Overvoltage shutdown,short circuit protection,output fuse protection. |
| Isolation | 4242VDC-inputand output 2121VDC-input and earth |
| Cooling | 707VDC-outputandearth One fan (front-to-back airflow) |
| Fan Speed | Tegmperature and output current |
| MTBF | v50oodia Rrs Tsmbent:25cC) |
| Acoustic Noise | ≤ 55dB at 220VAC input and full load (T_ambient: |
| Dimensions | 107Wx40.8Hx270D (mm) |
| Weight | 1.9Kg |
Applicable Standards
| Safety | IEC62368-1,UL62368-1, EN62368-1 |
| EMC | EN55032ClassA(emission) IEC61000-3-2 IEC61000-3-3 IEC610o0-4-2 (electrostatic discharge) IEC61000-4-3(Fiatedimunity) IEC61000-4-5 (surge immunity) IEC61000-4-6 (conducted immunity) IEC61000-4-8 |
| Environment | IEC61000-4-11 ETSI EN300 019-2(-1,-2,-3) ETSIEN300 132-2 |
Diagrams
HPR48-4000HE3
Introduction
HPR48-4oooHE3 isa high-performance digital rectifier module with photovoltaic input support.Exclusively engineeredfortelecom,network access and data centerapplications,it delivers outstanding operational reliability,excellent energy efficiencyand high power density in operation.
Features
Highefficiencyand high powerdensity 9 7 % efficiencyand 60.5W/in³ power density.
Digital control
Digital primary and secondary control,realizing excellent monitoring and regulation.
High reliability design
One fan front-to-back airflow with latest thermal solution and experienced design.
Disconnect mains when hazardous input
SPIll48/40o0HE disconnects mains to protect itself when it can not sustain the input voltage.
ExcellentEMCperformance
Lower interference and excellent susceptibility give the module a better compatibility.
Global approvals
MeetCE,ULandTUVstandard.
AC Input
| Voltage | 85-300VAC (Nominal:220VAC) |
| Frequency | 45-66Hz |
| Input Current | |
| PowerFactor | >0.99 |
| THDi |
DC Input
| Voltage | 85-400VDC (Nominal: 220VDC) |
| Input Current |
Photovoltaic Input
| Voltage | 85-400VDC |
| MPPT | >0.99 |
Output
| Voltage | 40-58VDC (Nominal 53.5VDC) |
| Power | 4350W |
| Max.Current | 90.6Aat48VDC |
| Static Voltage Regulation | |
| Dynamic Voltage Regulation | |
| Ripple | |
| Psophometric | |
| Current Sharing | |
| Holdup Time | >10ms |
| Startup Time | 3-8s |
| Efficiency | 97% |
Other Specifications
| Operating Temp. | -40℃~75℃ |
| Storage Temp. | -40℃~85℃ |
| Relative Humidity | |
| Altitude | 4000m |
| IPLevel | IP20 |
| Input Protection | 5KA lightning protection |
| Output Protection | Overvoltage shutdown,short circuit protection,output fuse protection. |
| Isolation | 4242VDC-inputand output 2121VDC-inputand earth 707VDC-outputand earth |
| Cooling | One fan (front-to-back airflow) |
| Fan Speed | Tegularatureand output current |
| MTBF | >35000 RrsTambient: 25C) |
| Acoustic Noise | ≤55dB at 220VAC input and full load (T_ambient: |
| Dimensions | 107Wx40.8Hx270D (mm) |
| Weight | 2.0Kg |
ApplicableStandards
| Safety | IEC62362-1,UL62368-1,EN62368-1 |
| EMC | EN55032 Class A(emission) EN55032 Class B (emission) EN 61000-3-12:2011 EN IEC 61000-3-11:2019 EN 55035:2017+A11:2020 IEC61000-3-2,IEC61000-3-3 IEC61000-2 (ectrestimuitchage) IEC61000-4-4 (EFT) IEC61000-4-5 (surge immunity) IEC61000-4-6 (conducted immunity) IEC61000-4-8 IEC61000-4-11 |
| Environment | ENIEC61000-6-4:2019 EN IEC 61000-6-2:2019 ETSI EN300 019-2 (-1,-2,-3) ETSI EN 300 132-2 |
Diagrams
HPR48-6000HE
Introduction
HPR48-6oooHE is a digital rectifier with outstanding reliability,efficiencyand powerdensity.It is specially designed fortelecom,networkaccessanddata center applications.
Features
Highefficiencyand high powerdensity 9 6 % efficiencyand 25.5W/in³ power density.
Digitalcontrol Digital primary and secondary control,realize excellent monitoringand regulation.
Highreliabilitydesign Onefan front-to-back air flow with latest thermal solution and experienced design. Excellent EMC performance Lower interference and excellent susceptibility give module better compatibility. Global approvals Meet CE,ULand TUVstandard.
Input
| Voltage | 208~530VAC(3phY) (Norminal 380VAC) |
| Frequency | 45Hz~66Hz |
| Input Current | |
| Power Factor | >0.99 |
| THDi |
Output
| Voltage | 43.2~58V DC (Nominal 53.5V DC) |
| Power | 6000W |
| Maximum Current | 125Aat48VDC |
| Static Voltage Regulation | ±0.5% |
| Ripple | |
| Psophometric | |
| Curint | |
| Hold up time | >10ms |
| Startup time | 3~8S |
| Efficiency | 96% |
Other Specifications
| Operating temp | -40℃~+75℃ |
| Storage temp | -40℃~+85℃ |
| Relative humidity | |
| Altitude | 2000m |
| IP level | IP20 |
| Input protection | 5KA lightning protection |
| Output protection | 59.5±0.5Vdc Overvoltage shutdown Short circuit proof Output fuse |
| Isolation | 3.0KVAC-input and output 1.5KVAC-input and earth 0.5KVAC-outputandearth |
| Cooling | One fan (front to back airflow) |
| Fan speed | Temperature and output currentregulated |
| MTBF | >200,0o0 hours (T_ambient:25℃) Telcordia SR-332 Issue 1 |
| Acoustic noise | ≤55dB at 220vAC input and full load (T_ambient |
| Dimensions | 108W× 86 H×418D (mm) |
| Weight |
ApplicableStandards
| Safety | IEC62368-1,UL62368-1,EN62368-1 |
| EMC | EN55032 Class A (emission) EN61000-3-12:2011 EN IEC61000-3-11:2019 EN55035:2017+A11:2020 IEC61000-3-2C61000-3-3 IEC61000-4-2(electrostatic discharge) IEC61000-4-3 (radiated immunity) IEC61000-4-4EFT) IEC61000-4-5 (surgeimmunity) IEC61000-4-6 (conducted immunity) IEC61000-4-8 |
| Environment | IEC61000-4-11 ETSI EN 300 019-2 (-1.-2,-3) ETSIEN300132-2 |
Diagrams
HPR48-6000SE
Introduction
HPR48-6oooSE is a digital rectifier with outstanding reliability,efficiencyand powerdensity.It is specially designed fortelecom,networkaccessanddata center applications.
Features
·High efficiency and high power density 9 7 % efficiencyand 25.5W/in' power density.
·Digital control Digital primary and secondary control,realize excellent monitoring and regulation.
Highreliabilitydesign One fan front-to-back air flow with latest thermal solution and experienced design. Excellent EMC performance Lower interference and excellent susceptibility give module better compatibility. Global approvals Meet CE,ULand TUV standard.
Input
| Voltage | 208~530VAC(3phY) (Nominal 380VAC) |
| Frequency | 45Hz~66Hz |
| Input Current | |
| Power Factor | >0.99 |
| THDi |
Output
| Voltage | 42~58V DC (Nominal 53.5V DC) |
| Power | 6000W |
| Maximum Current | 125Aat48VDC |
| Static Voltage Regulation | ±0.5% |
| Ripple | |
| Psophometric | |
| Curnt | |
| Hold up time | >10ms |
| Startup time | 3~8S |
| Efficiency | 97% |
Other Specifications
Diagrams
| Operating temp | -40℃~+75℃ |
| Storage temp | -40℃~+85℃ |
| Relative humidity | |
| Altitude | 2000m |
| IP level | IP20 |
| Input protection | 5KA lightning protection |
| Output protection | 59.5±0.5Vdc Overvoltage shutdown Short circuit proof Output fuse |
| Isolation | 4242VDC-input and output 2121VDC-input and earth 707VDC-outputandearth |
| Cooling | One fan (front to back airflow) |
| Fan speed | Temperatureand output current regulated |
| MTBF | >300,0oo hours(T_ambient:25℃) Telcordia SR-332 Issue 1 |
| Acoustic noise | ≤55dB at 220VAC input and full load (T_ambient |
| Dimensions | 108W×86 Hx418D (mm) |
| Weight |
Applicable Standards
| Safety | IEC62368-1,UL62368-1,EN62368-1 |
| EMC | EN55032 ClassA(emission) EN 61000-3-12:2011 EN IEC61000-3-11:2019 EN55035:2017+A11:2020 IEC61000-3-2C61000-3-3 IEC61000-4-2(electrostatic discharge) IEC61000-4-3(radiated immunity) IEC61000-4-4EFT) IEC61000-4-5 (surge immunity) IEC61000-4-6 (conducted immunity) IEC61000-4-8 |
| Environment | IEC61000-4-11 ETSI EN 300 019-2 (-1.-2,-3) ETSIEN300 132-2 |
HPS150-48-4000
Introduction
HPS150-48-4000 is an non-isolated DC/DC converterwhich has the MPPT function.It can extract maximum power in real time from the solar panels throughout the day.Module can work in outstandingreliability,eficiencyand powerdensity.It is speciallydesigned for telecom,network accessand data centerapplications.
Features
High efficiency and high power density 9 8 % efficiencyand 55.8W/in³ powerdensity. MPPTefficiencyis higherthan 9 9 . 8 %
High reliability design
One fan front-to-back air flow with latest thermal solution and experienced design.
ExcellentEMC performance
Lower interference and excellent susceptibility give module better compatibility.
Globalapprovals Meet CE,ULandTUVstandard.
DC Input
| Voltage | 58-170VDC (Nominal: 100VDC) |
| MPPTEfficiency | > 0.998 |
| Input Current |
Output
| Voltage | 42-58VDC(Nominal 53.5VDC) |
| Power Max.Current | 4000W 80Aat50.2VDC |
| Static Voltage Regulation | |
| Dynamic Voltage Regulation | |
| Ripple | |
| Psophometric | |
| Startup Time | 3-8s |
| Efficiency | 98% |