51
4.10 Electronic control board SMT placement technology
The electronic control main board adopts SMT patch sealing technology to improve the anti-clutter interference,
to ensure that the main board is not affected by wind, sand, high temperature and high humidity, and to make the
main control board longer.
SMT
CPU
4.11 Anti-snow function
In the snowy weather conditions in winter, in order to prevent the snow from adversely affecting the top of the
outdoor unit fan,you can turn on anti-snow mode, the fan starts running to clear the snow to ensure the normal
operation of the unit.
52 The TMV6+ is designed for diverse application scenarios, with its
installation environment requirements carefully considered. Its appearance
and functional design incorporate user-centric details that significantly
enhance installation convenience, accelerate the process, and simplify
future maintenance.
CONVENIENT INSTALLATION
AND MAINTENANCE
15 basic modules, satisfy
all kind of requirement
Big-capacity module design, easy
installation and space saving
Emergency power-off
function for indoor unit
maintenance
Super long refrigerant
pipeline design,
flexible structure
1100 Convenient for the transportation,
installation and commissioning
130Pa high static
pressure for outdoor unit
ODU without oil balance pipe,
compact design
Commissioning software Auto-addressing
function
52
53
53
53
54 110m
100m
120m 40m
The biggest
drop when
ODU on the top The biggest
drop when ODU
at the bottom
Maximum
drop of IDU
Furthest IDU
Nearest IDU IDU
The industry-leading piping length, with a total length
of 1100m, makes floor design more flexible.
The max distance between the IDU and the ODU (the
higher ODU) is 100m. The max distance between the
IDU and the ODU (the lower ODU) is 110m.
The maximum distance between indoor units is 40m.
The maximum actual single pipe length is 220m.
The maximum equivalent single tube length is 240m.
The equivalent length from first indoor distributor to
last indoor unit 120m.
Convenient Installation and Maintenance
Smaller body size saves installation space.
Less installation materials, saving purchase costs.
TMVS 2 ODUs in parallel TMV6 ODU
Parallel connection 18HP Parallel connection 18HP
Power cord and ground
ODU&IDU communication
line Refrigerant gas side
Liquid refrigerant side
Communication line between ODU
Oil balance between outdoor pipe
A single module 36HP
Large-capacity Module Design, Convenient Installation And Space Saving
The maximum capacity of a single unit is 36HP.
Reduce the workload of wiring, save labor cost and
construction period.
5.1
5.2 1100m Super Long Piping Design
55
5.3 130Pa External Static Pressure *
Engineered with advanced fan blades and a high-performance inverter motor, the system delivers a superior external
static pressure of 130Pa*. This ensures reliable and efficient heat dissipation.
Better heat dissipation, better refrigeration effect VRF static pressure contrast diagram
MAX 130Pa
*Customizable to 130Pa
One-touch commissioning function
You can choose to debug on the outdoor unit side or remotely through the monitoring software to realize the cooling
and heating trial operation, no need opening the indoor units one by one, which is convenient for on-site debugging
and improves the quality of construction at the project site.
5.5
925mm 845mm 1340mm 1760mm 1900mm
8 to 10HP 12 to 18HP 20 to 26HP 28 to 30HP
845mm 845mm 845mm
1780mm 1780mm 1780mm 1780mm
Compact design and convenient transport
The outdoor unit module has only 4 basic structures with the same height, which simplifies the design process and
improves the flexibility of the system.
5.4
5.6 Non-polarity communication connection
CAN bus communication mode is applied between indoor and outdoor unit, no need to distinguish between
positive and negative poles, and the installation is simpler and more efficient.
56 Convenient Installation and Maintenance
360°pipe Connection Design
These units allow the freedom to connect the piping in multiple
directions, such as front side, left side , right side and back side ,
making installation easier.
5.8
Emergency Power-off Function For IDU Maintenance
If an indoor unit requires power outage for maintenance due to a malfunction, it can be independently powered off
for repair without affecting the operation of the entire system. Other indoor units within the system can continue to
operate normally.
5.9
2 IDU separately power off for maintenance
The outdoor units without oil equalizing pipe, which
are more convenient for installation and also reduces
the error of pipeline leakage.
Equalizing tubing
Refrigerant trachea
Liquid refrigerant tube
Cancel equalizing tubing
5.7 No Oil balance Pipe For ODU
57
Commissioning Software
The commissioning software is specially developed for TCL air-conditioning system, which can carry out real-time
status monitoring and loading control of the air-conditioning system.
It can monitor the real-time operation parameters of 4 outdoor units and 80 indoor units in parallel system; And the
operating parameters can be showed in Curve; It contains the function of saving the original data of operation, which
is convenient for the R & D Engineers to remotely analyze the cause of failure; It also contains the forced load control
function of the equipment, which is convenient for loading maintenance verification on the project site.
4 ODUs
MAX
80 IDUs
5.10
Auto-addressing Function
The system can realize the automatic allocation of indoor unit address. There is no need to dial code during
commissioning, which avoids the trouble of manual setting one by one. It is more intelligent and convenient.
5.11
58 ODU lineup
8 to 10 HP
20 to 26 HP
12 to 18 HP
28 to 30 HP
Product Specifications
The outdoor unit module has only 3 basic structures with the same height, which simplifies the design process and
improves the flexibility of the system.
59
ODU Specifications (8-30HP)
Model:
TMV-Vd+(**)W/N1S-C(E3)
252 280 335 400 450 504 560 615 680 730 785 850
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP
Power Supply V~,Ph,Hz 380-415V, 3N, 50/60Hz
Cooling
(T1)
Capacity kW 25.2 27.9 33.3 40.0 45.0 50.5 56.5 61.5 68.0 73.5 78.5 85.0
Capacity Btu/h 86000 95000 114000 136000 154000 172000 192000 210000 232000 250000 268000 290000
Input kW 5.30 6.05 7.50 9.20 10.60 12.15 13.85 15.50 17.70 19.20 20.90 22.90
Current A 8.09 9.23 11.44 14.04 16.17 18.54 21.13 23.65 27.00 29.29 31.88 34.94
EER W/W 4.76 4.61 4.44 4.35 4.25 4.16 4.08 3.97 3.84 3.83 3.76 3.71
EER Btu/
(W·h) 16.250 15.700 15.200 14.800 14.550 14.150 13.850 13.550 13.100 13.000 12.800 12.650
Cooling
(T3)
Capacity kW 23.1 25.5 30.9 36.5 40 46.5 51 57 61.5 66.5 71.5 77.5
Capacity Btu/h 79000 87000 105000 124000 136000 158000 174000 194000 210000 226000 244000 264000
Input kW 6.80 7.60 9.25 11.05 12.80 14.49 16.11 17.93 19.65 21.37 23.09 25.14
Current A 10.37 11.59 14.11 16.86 19.53 22.10 24.58 27.35 29.97 32.59 35.22 38.36
EER W/W 3.40 3.36 3.34 3.30 3.13 3.21 3.17 3.18 3.13 3.11 3.10 3.08
EER Btu/
(W·h) 11.600 11.450 11.350 11.200 10.650 10.900 10.800 10.800 10.700 10.600 10.550 10.500
Heating
Capacity kW 27 30.9 37.5 45 50 56 63 69 75 81.5 87.5 95
Capacity Btu/h 92000 105000 128000 153000 171000 191000 215000 235000 256000 278000 299000 324000
Input kW 5.35 5.98 7.40 9.25 10.96 12.48 14.10 15.72 17.34 18.95 20.57 22.19
Current A 8.16 9.12 11.29 14.11 16.72 19.04 21.51 23.98 26.45 28.92 31.39 33.85
COP W/W 5.04 5.17 5.07 4.87 4.56 4.49 4.47 4.39 4.32 4.3 4.25 4.28
COP Btu/
(W·h) 17.200 17.550 17.300 16.550 15.600 15.350 15.250 14.950 14.750 14.650 14.550 14.600
Max. Input
Consumption kW 11.30 12.43 13.73 16.25 18.40 21.39 23.70 26.07 29.68 31.49 33.27 33.47
Max. Current A 20 22 24.3 28.8 32.6 37.9 42 46.2 52.6 55.8 58.95 59.31
Outdoor Fan Motor
(Output Power x Fan
quantity)
W 560x1 920x1 560x2 920x2
Air Flow Volume m3
/h 11000 11000 14000 15500 19000 19000 26000 27000 27000 29000 29000 29000
Noise Level dB(A) 58 59 60 61 62 63 63 64 64 65 65 66
Dimension
(W×D×H)
Net mm 925×1780×845 1340×1780×845 1760×1780×845 1900×1780×845
Packing mm 1000×1940×925 1415×1940×925 1835×1940×925 1975×1940×925
Weight
Net kg 230 230 270 270 315 315 380 380 420 420 480 480
Gross kg 240 240 290 290 335 335 405 405 445 445 505 505
Refrigerant
type/
Quantity
Type / R410A
Charged
Volume kg 11 11 12 12 14 14 18 18 23 23 28 28
Design Pressure MPa 4.3/1.5 4.3/1.5 4.3/1.5 4.3/1.5 4.3/1.5 4.3/1.5 4.3/1.5 4.3/1.5 4.3/1.5 4.3/1.5 4.3/1.5 4.3/1.5
Refrigerant
Piping
Liquid
Side mm φ12.7 φ12.7 φ12.7 φ12.7 φ15.88 φ15.88 19.05 19.05 19.05 19.05 19.05 19.05
Gas Side mm φ25.4 φ25.4 φ28.6 φ28.6 φ28.6 φ28.6 φ31.8 φ31.8 φ31.8 φ31.8 34.9 34.9
Max.
Length m 1100
Max.
Height m 110(100)
Ambient Temp
(Cooling/Heating) °C -15~56/-25~28
Notes:
1. Cooling conditions: Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Heating: Indoor temperature 20°C DB/15°C WB,and outdoor temperature 7°C DB/6°C WB
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
60 VRF systems, Various combinations
In response to the different needs of building types for air-conditioning equipment, TCL provides four basic
outdoor unit modules, which can be freely combined in 2HP increments, and the maximum combination can reach
120HP, which can meet the high level design capacity differentiation, installation and transportation requirements of
large and medium-sized air-conditioning projects .
Recommended combination table
HP Combination1
(Space saving)
Combination2
(High efficiency)
Connected
indoor unit
qty.
HP Combination1
(Space saving)
Combination2
(High efficiency)
Connected
indoor unit
qty.
8 8 8 13 62 18+22+22 16+16+16+14 80
10 10 10 16 64 20+22+22 16+16+16+16 80
12 12 12 19 66 22+22+22 18+16+16+16 80
14 14 14 23 68 24+22+22 18+18+16+16 80
16 16 16 26 70 26+22+22 18+18+18+16 80
18 18 18 29 72 26+20+20 18+18+18+18 80
20 20 20 33 74 22+26+26 20+18+18+18 80
22 22 22 36 76 24+26+26 20+20+18+18 80
24 24 12+12 39 78 26+26+26 20+20+20+18 80
26 26 14+12 43 80 28+26+26 20+20+20+20 80
28 28 16+12 46 82 30+26+26 22+20+20+20 80
30 30 16+14 50 84 30+30+24 22+22+20+20 80
32 18+14 53 86 30+30+26 22+22+22+20 80
34 18+16 56 88 30+30+28 22+22+22+22 80
36 18+18 59 90 30+30+30 80
38 18+20 14+12+12 63 92 22+22+24+24 80
40 22+18 14+14+12 66 94 22+24+24+24 80
42 20+22 14+14+14 69 96 24+24+24+24 80
44 22+22 16+14+14 72 98 26+24+24+24 80
46 24+22 16+16+14 78 100 26+26+24+24 80
48 22+26 16+16+16 80 102 26+26+26+24 80
50 24+26 18+16+16 80 104 26+26+26+26 80
52 26+26 18+18+16 80 106 28+26+26+26 80
54 28+26 18+18+18 80 108 28+28+26+26 80
56 26+30 14+14+14+14 80 110 28+28+28+26 80
58 28+30 16+14+14+14 80 112 28+28+28+28 80
60 30+30 16+16+14+14 80 114 30+28+28+28 80
116 30+30+28+28 80
118 30+30+30+28 80
120 30+30+30+30 80
Product Specifications
61
HP 32 34 36 38 40 42 44 46
Recommended
combination 18+14 18+16 18+18 20+18 22+18 20+22 22+22 24+22
Model
(TMV-Vd+***W/N1S-C(E3)) 904 954 1008 1065 1119 1184 1240 1295
Naminal cooling *1 (kW) 82 86 92 97 102.5 107.5 113 118
Naminal heating*2 (kW) 101 106 112 119 125 132 138 144
Rated cooling
power input (kW) 23.85 27.29 28.98 30.60 32.42 29.98 35.86 37.58
Rated heating
power input (kW) 21.73 23.44 24.96 26.58 28.20 29.82 31.44 33.06
Power supply / 380V ~ 3N 50Hz/60Hz
Compressor type - DC Inverter Scroll
Dimension
(W×D×H) (mm) (1340×1780×845)×2 1760×1780×845+
1340×1780×845 (1760×1780×845)×2
Motor
Type DC Inverter
Air
volume m³/h 34500 38000 38000 45000 46000 53000 54000 54000
Drive type Direct
Net weight kg 585 730 730 695 695 760 760 800
Operation noise *3 dB(A) 63 63 64 64 65 65 65 65
HP 48 50 52 54 56 58 60
Recommended
combination 22+26 24+26 26+26 28+26 26+30 30+28 30+30
Model
(TMV-Vd+***W/N1S-C(E3)) 1360 1400 1465 1515 1570 1630 1685
Nominal cooling *1 (kW) 123 128 133 138 143.5 148.5 154
Nominal heating*2 (kW) 150.5 156.5 163 169 176.5 182.5 190
Rated cooling
power input (kW) 39.30 41.05 42.74 44.46 46.42 48.14 50.10
Rated heating
power input (kW) 34.67 36.29 37.90 39.52 41.14 42.76 44.38
Power supply / 380V ~ 3N 50Hz/60Hz
Compressor type - DC Inverter Scroll
Dimension
(W×D×H) (mm) (1760×1780×845)×2 1900×1780×845+
1760×1780×845 (1900×1780×845)×2
Motor
Type DC Inverter
Air
volume m³/h 56000 56000 58000 58000 58000 58000 58000
Drive type Direct
Net weight kg 800 840 840 900 900 960 960
Operation noise *3 dB(A) 66 66 66 66 67 67 67
2 ODUs
Space Saving Combination
Notes:
1. Cooling conditions: Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Heating: Indoor temperature 20°C DB/15°C WB,and outdoor temperature 7°C DB/6°C WB
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
62 3 ODUs HP 62 64 66 68 70 72 74
Recommended
combination 18+22+22 20+22+22 22+22+22 24+22+22 26+22+22 26+26+20 22+26+26
Model
(TMV-Vd+***W/N1SC(E3))
1750 1800 1850 1900 1950 2000 2080
Nominal cooling
capacity *1 (kW) 159 164 169.5 174.5 179.5 184 189.5
Nominal heating
capacity *2 (kW) 194 201 207 213 219.5 226 232
Reted cooling
power input (kW) 50.35 51.97 53.79 55.51 57.23 58.85 60.67
Rated heating
power input (kW) 43.92 45.54 47.16 48.78 50.39 52.00 53.62
Power supply / 380V ~ 3N 50Hz/60Hz
Compressor type - DC inverter Scroll
Dimension
(W×D×H) (mm) 1340×1780×845+
(1760×1780×845)×2 (1760×1780×845)×3
Motor
Type DC Inverter
Air volume m³/h 73000 80000 81000 81000 83000 84000 85000
Drive type Direct
Net kg 1075 1140 1140 1180 1180 1220 1220
Operation level *3 dB(A) 67 67 67 67 68 68 68
HP 76 78 80 82 84 86 88 90
Recommended
combination 24+26+26 26+26+26 28+26+26 30+26+26 30+30+24 30+28+28 30+30+28 30+30+30
Model
(TMV-Vd+***W/N1SC(E3))
2145 2185 2250 2300 2355 2415 2470 2530
Nominal cooling *1 (kW) 194.5 199.5 204.5 210 215.5 220 225.5 231
Nominal heating
*2 (kW) 238 244.5 250.5 258 265 270 277.5 285
Rated cooling
power input (kW) 62.39 64.11 65.83 67.79 69.75 71.23 73.19 75.15
Rated heating
power input (kW) 55.24 56.85 58.47 60.09 61.72 63.33 64.95 66.57
Power supply / 380V ~ 3N 50Hz/60Hz
Compressor type - DC inverter scroll
Dimension
(W×D×H) (mm) 85000 87000 87000 87000 88000 89000 89000 89000
Motor
Type DC inverter
Air volume m³/h (1760×1780×845)×3 1900×1780×845+
(1760×1780×845)×2
(1900×1780×845)×2
+1760×1780×845 (1900×1780×845)×3
Drive way Direct
Net weight kg 1260 1260 1320 1320 1380 1440 1440 1440
Operation noise*3 dB(A) 68 68 68 69 69 69 69 69
Space Saving Combination Product Specifications
Notes:
1. Cooling conditions: Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Heating: Indoor temperature 20°C DB/15°C WB,and outdoor temperature 7°C DB/6°C WB
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
63
4 ODUs
HP 92 94 96 98 100 102 104 106
Recommended
combination 22+22+24+24 22+24+24+24 24+24+24+24 26+24+24+24 26+26+24+24 26+26+26+24 26+26+26+26 28+26+26+26
Model
(TMV-Vd+***W/N1SC(E3))
2585 2650 2700 2750 2800 2850 2900 2950
Nominal cooling
capacity *1 (kW) 236 241 246 251 256 261 266 271
Nominal heating
capacity *2 (kW) 288 294 300 306.5 313 319.5 326 332
Reted cooling
power input (kW) 75.16 76.88 78.60 80.32 82.04 83.76 85.48 87.20
Rated heating
power input (kW) 66.12 67.74 69.36 70.97 72.58 74.19 75.80 77.42
Power supply / 380V ~ 3N 50Hz/60Hz
Compressor type - DC inverter Scroll
Dimension
(W×D×H) (mm) (1760×1780×845)×4 1900×1780×845+
(1760×1780×845)×3
Motor
Type DC inverter
Air
volume m³/h 108000 108000 108000 110000 112000 114000 116000 116000
Drive type Direct
Net weight kg 1600 1640 1680 1680 1680 1680 1680 1740
Operation
noise*3 dB(A) 67 67 67 68 68 68 68 68
HP 108 110 112 114 116 118 120
Recommended
combination 28+28+26+26 28+28+28+26 28+28+28+28 30+28+28+28 30+30+28+28 30+30+30+28 30+30+30+30
Model
(TMV-Vd+***W/N1SC(E3))
3000 3085 3140 3200 3255 3315 3370
Nominal
cooling*1 (kW) 276 281 286 291.5 297 302.5 308
Nominal
heating*2 (kW) 338 344 350 357.5 365 372.5 380
Rated cooling
power input (kW) 88.92 90.64 92.36 94.32 96.28 98.24 100.2
Rated heating
power input (kW) 79.04 80.66 82.28 83.90 85.52 87.14 88.76
Power supply / 380V ~ 3N 50Hz/60Hz
Compressor
type - DC inverter scroll
Dimension
(W×D×H) (mm) (1900×1780×845)×2+
(1760×1780×845)×2
(1900×1780×845)×3
+1760×1780×845 (1900×1780×845)×4
Motor
Type DC inverter
Air
volume m³/h 116000 116000 116000 119000 119000 119000 119000
Drive type Direct
Net weight kg 1800 1860 1920 1920 1920 1920 1920
Operation
noise*3 dB(A) 68 68 68 69 69 69 69
Space Saving Combination
Notes:
1. Cooling conditions: Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Heating: Indoor temperature 20°C DB/15°C WB,and outdoor temperature 7°C DB/6°C WB
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
64 HP 24 26 28 30
Recommended combination 12+12 14+12 16+12 16+14
Model (TMV-Vd+***W/N1S-C(E3) 670 735 785 850
Nominal cooling *1 (kW) 61.8 66.9 70.9 76
Nominal heating *2 (kW) 75 82.5 87.5 95
Rated cooling power
input (kW) 18.50 20.30 22.05 23.85
Rated heating power
input (kW) 14.80 16.65 18.36 20.21
Power supply / 380V ~ 3N 50Hz/60Hz
Compressor type - DC inverter Scroll
Dimension(W×D×H) (mm) (1340×1780×845)×2
Motor
Type DC Inverter
Air volume m³/h 28000 29500 33000 34500
Drive way Direct
Net weight kg 540 540 585 585
Operation noise *3 dB(A) 61 61 62 62
HP 38 40 42 44 46 48 50 52 54
Recommended combination 14+12+12 14+14+12 14+14+14 16+14+14 16+16+14 16+16+16 18+16+16 18+18+16 18+18+18
Model
(TMV-Vd+***W/N1S-C(E3)) 1065 1119 1184 1240 1295 1360 1400 1465 1515
Nominal cooling *1 (kW) 97.8 102.9 108 112 116 120 126 132 138
Nominal heating *2 (kW) 120 127.5 135 140 145 150 156 162 168
Rated cooling
power input (kW) 29.55 31.35 33.15 34.90 36.65 38.40 40.09 41.78 43.47
Rated heating
power input (kW) 24.05 25.90 27.75 29.46 31.17 32.88 34.40 35.92 37.44
Power supply / 380V ~ 3N 50Hz/60Hz
Compressor type - DC inverter scroll
Dimension
(W×D×H) (mm) (1340×1780×845)×3
Motor
Type DC inverter
Air volume m³/h 43500 45000 46500 50000 53500 57000 57000 57000 57000
Drive type Direct
Net weight kg 810 810 810 855 900 945 945 945 945
Operation noise *3 dB(A) 64 64 64 65 65 65 66 66 66
2 ODUs 3 ODUs
High Efficiency Combination Product Specifications
Notes:
1. Cooling conditions: Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Heating: Indoor temperature 20°C DB/15°C WB,and outdoor temperature 7°C DB/6°C WB
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
65
4 ODUs
HP 74 76 78 80 82 84 86 88
Recommended
combination 20+18+18+18 20+20+18+18 20+20+20+18 20+20+
20+20
22+20+
20+20
22+22+
20+20
22+22+
22+20
22+22+
22+22
Model
(TMV-Vd+***W/N1S-C(E3)) 2072 2128 2184 2240 2295 2350 2405 2460
Nominal cooling *1 (kW) 189 194 199 204 209.5 215 220.5 226
Nominal heating
capacity *2 (kW) 231 238 245 252 258 264 270 276
Reted cooling
power input (kW) 59.58 61.20 62.82 64.44 66.26 68.08 69.90 71.72
Rated heating
power input (kW) 51.54 53.16 54.78 56.40 58.02 59.64 61.26 62.88
Power supply / 380V ~ 3N 50Hz/60Hz
Compressor type - DC inverter Scroll
Dimension
(W×D×H) (mm) (1760×1780×845)+
(1340×1780×845)×3
(1760×1780×845)×2+
(1340×1780×845)×2
(1760×1780×845)×3
+(1340×1780×845) (1760×1780×845)×4
Motor
Type DC inverter
Air volume m³/h 83000 90000 97000 104000 105000 106000 107000 108000
Drive type Direct
Net weight kg 1325 1390 1455 1520 1520 1520 1520 1520
Operation noise *3 dB(A) 66 66 66 66 67 67 67 67
High Efficiency Combination
HP 56 58 60 62 64 66 68 70 72
Recommended
combination 14+14+14+14 16+14+14+14 16+16+14+14 16+16+16+14 16+16+16+16 18+16+16+16 18+18+16+16 18+18+18+16 18+18+18+18
Model
(TMV-Vd+***W/N1SC(E3))
1600 1650 1700 1750 1800 1854 1908 1962 2016
Nominal cooling
capacity *1 (kW) 144 148 152 156 160 166 172 178 184
Nominal heating
capacity *2 (kW) 180 185 190 195 200 206 212 218 224
Reted cooling
power input (kW) 44.20 45.95 47.70 49.45 51.20 52.89 54.58 56.27 57.96
Rated heating
power input (kW) 37.00 38.71 40.42 42.13 43.84 45.36 46.88 48.40 49.92
Power supply / 380V~3N 50Hz/60Hz
Compressor type - DCinverter Scroll
Dimension
(W×D×H) (mm) (1340×1780×845)×4
Motor
Type DCinverter
Air
volume m³/h 62000 65500 69000 72500 76000 76000 76000 76000 76000
Drive type Direct
Net weight kg 1080 1125 1170 1215 1260 1260 1260 1260 1260
Operation
noise*3 dB(A) 64 65 65 65 65 66 66 66 66
Notes:
1. Cooling conditions: Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Heating: Indoor temperature 20°C DB/15°C WB,and outdoor temperature 7°C DB/6°C WB
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
66 Mini VRF
Full DC Inverter Tropical Unit
Powerful High Efficiency Comfortable Stable
67
68 High efficiency full DC inverter and twin rotary compressor
High energy efficiency
High efficiency DC fan motor Electrical control box refrigerant cooling technology
Strong Power, Stable Operation
Energy Saving And Environmental Friendly
7.1
7.2
TCL Mini VRF use full DC inverter twin rotary compressor, which has highefficiency both for full load condition and partial load condition, also leads to
low noise, stable and reliable operation.
The TCL mini VRF adopts full DC inverter
compressor, DC fan motor, high-precision
electronic expansion valve to create a
durable system .
The stepless regulation of the fan
motor can meet the actual requirement
of the capacity output, efficiency of
motor is increased up to be 45%, higher
efficiency in low speed operation.
The refrigerant cooling technology can cool the PCBs in high
ambient temperature condition, which improves the reliability,
effciency and lifespan of the MINI VRF units.
80°C
60°C
Temperature
drop
Wide operation temperation range
The Mini VRF can operate under -25℃ to ensure the heating demand, operate up to 54℃ to make sure the cooling
capcity output with high efficiency and stability.
MINI VRF
69
R410A High-efficiency and environmentally friendly refrigerant
RoHS Certification
R410A is an HFC refrigerant which does not damage the ozone layer. It is an
energy efficient and environmentally friendly refrigerant.
The TCL mini VRF unit meets the RoHS
enviromental certification, which is environmental
friendly.
R410A is non-toxic and is a \"non-flammable refrigerant\". The composition
structure of R410A is not easy to change and very stable.
7.4Beautiful Appearance, Upgraded Structure Design
The top panel
Right front side plate
Grille
Right back plate
Footing
Seal plate
The front panel Lifting handle
No screw design to get high-quality
structure and improve the strength, more
beautiful
Mold forming and integrated design to
make sure the strength of the panel
Grille adopts DOE simulation design, air
volume increased more than 7%
The mold is integrally formed and the
new designed diffuser improves the
heat exchange efficiency.
High strength foundation with rust - proof,
corrosion - proof, more stable and reliable. Ensure simple pipe connection.
Double 528mm wind wheel, larger air
volume and lower noise.
Upgraded handle design, easy to
carry
Simple and elegant appearance
The front, side and back of the unit are
designed with knock-out holes, coper
pipes can be connected from various
directions, which is more convenient to
do the installation.
Sealing plate is combined with knock-out plate
Three side pipe connection design
Different installation options
Three side direction pipe connection
70 7.5 Mini VRF Specifications
MINI VRF Specifications
10-16 KW 18-22.4 KW
Items Unit
100 120 140 160 180 224
Model: TMV-Vd(**)W/N1-C(E3)
Power Supply V~,Hz,Ph 220-240V, 50/60Hz, 1N 380-415V, 50/60Hz, 3N
Cooling
(T1)
Capacity W 10,200 12,000 14,100 15,900 18,000 22,500
Input W 2,080 2,750 3,410 4,050 4,600 5,750
Current A 9.04 11.96 14.83 17.61 7.02 8.77
EER W/W 4.82 4.37 4.13 3.94 3.91 3.87
Cooling
(T3)
Capacity W 9,300 10,500 12,000 13,500 16,500 19,200
Input W 2,730 3,110 3,390 4,300 5,760 6,860
Current A 11.86 13.54 14.75 18.7 8.79 10.46
EER W/W 3.47 3.4 3.54 3.16 2.9 2.72
Heating
Capacity W 11,700 13,800 15,900 18,000 19,800 24,600
Input W 2,640 3,130 3,630 4,240 4,820 6,050
Current A 11.48 13.59 15.76 18.41 7.35 9.23
COP W/W 4.43 4.42 4.39 4.25 4.11 4.07
Max. Input Consumption W 6,000 6,000 6,900 7,200 11,000 12,000
Max. Current A 27.8 27.8 31.4 33 17.6 19.2
Circuit breaker A 40 40 40 40 25 25
Air Flow Volume m3
/h 5900 5900 6500 7000 10500 10500
Noise Level dB(A) 53 53 54 55 58 61
Dimension
(W×D×H)
Net mm 950×340×1330 1120×400×1560
Packing mm 1080×430×1480 1080×430×1480 1080×430×1480 1080×430×1480 1250×560×1721 1250×560×1721
Weight
Net kg 91 91 94 99 130 140
Gross kg 102 102 105 110 145 163
Cooling
operating range
Outdoor side °C -5~55
Indoor side °C 16~32
Heating
operating range
Outdoor side °C -20~24
Indoor side °C 15~31
Notes: 1. Cooling conditions: Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Heating: Indoor temperature 20°C DB/15°C WB,and outdoor temperature 7°C DB/6°C WB
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
71
IDU lineup
Series Fan motor Model
Capacity range(x100w)
18 22 25 28 32 36 40 45 50 56 63 71 80 90 100 112 125 140 160 180 220 280 450 560
360° Q8
cassette
DC TMV-V(**)Q8/
N1DY(E) ● ● ● ● ● ● ● ● ● ● ● ● ● ●
compact
cassette
DC TMV-V(**) Q4R/
N1D1Y (E) ● ● ● ● ● ● ● ● ● ●
Low ESP
Slim duct
DC TMV-V(**)F5/
N1DY(E) ● ● ● ● ● ● ● ● ● ● ● ● ●
Free static
pressure duct
DC TMV-V(**) F2/
N1DY(E) ● ● ● ● ● ● ● ● ● ● ● ● ●
Wall-mounted
(External EXV)
DC TMV-V(**)G/
N1DY-B(E) ● ● ● ● ● ● ● ● ● ●
Wall-mounted
(Built-in EXV)
AC TMV-V(**)G/
N1Y-B(E) ● ● ● ● ● ● ● ●
High static
pressure duct
AC TMV-V(**)F1/
N1Y(E) ● ● ● ●
Fresh air
duct
AC TMV-V(**) F1/
XFN1Y(E) ● ● ● ●
Celilling
& Floor
AC TMV-V(**) ZD/
N1Y(E) ● ● ● ● ● ● ● ● ● ● ●
One-way
cassette
DC TMV-V(**) Q1/
N1DY(E) ● ● ● ● ● ● ●
Two-way
cassette
AC TMV-V(**)Q2/
N1Y(E) ● ● ● ● ● ● ● ●
72 360° Q8 Cassette
Technical characteristics
Recommended places
Office, restaurant, supermarket, shopping mall, lobby, etc
360° Airflow
Experience a gentle breeze in every corner. Our system ensures
uniform air distribution to eliminate hot and cold spots, maintaining a
consistently comfortable temperature throughout your space.
Large Air Outlet Volume
Through the new DC inverter fan motor,
achieve 2100m³/h air outlet volume, and
improve the air Exchange efficiency by 30%
Soft Wind Panel
The optional Soft Wind Panel creates a 360° airflow for superior
comfort. Air is dispersed through 2,565 micro-holes, which break up the
direct airflow into a gentle, body-friendly breeze.
*This is optional
Built-in DC Drain Pump
The drain pump delivers a maximum lift height
of 1200 mm, simplifying installation and
enabling efficient condensate drainage from
the indoor unit.
Standard Float Switch, Timely Warning
Standard float switch, when the condensate
pump is faulty or the drainpipe is blocked,
timely warning, prevent the water tray inside
the machine overflow.
Ultra Low Noise
Using the advanced technology of threedimensional spiral blade design, can reduce the
air resistance, realize the machine low noise
operation, \"quiet\" enjoy a comfortable life.
27dB(A)
Clean Sterilization, Healthy Life
Standard health filter screen, effectively
remove large particles in the air, optional
silver ion purification module, adsorption of
formaldehyde and odor, eliminate germs.
DC Inverter Fan Motor Technology
Adoption DC inverter motor technology, to
improve the running efficiency by 15% and
reduce the operation noise (min 27dB)
IDU Lineup & Specifications
73
360° Q8 Cassette
Specification
Items Unit 28 36 45 50 56 63 71 Indoor Model: TMV-V(**)Q8/N1DY(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50/60Hz, 1Ph
Capacity
Cooling
Btu/h 10000 12000 15000 17000 19000 21000 24000
KW 2.8 3.6 4.5 5 5.6 6.3 7.1
Heating
Btu/h 11000 14000 17000 19000 21000 24000 27000
KW 3.2 4 5 5.6 6.3 7.1 8
Electric
Data
(T1)
Rated Cooling Power Input KW 0.02 0.025 0.035
Rated Heating Power Input KW 0.02 0.025 0.035
Rated Cooling Current A 0.09 0.11 0.16
Rated Heating Current A 0.09 0.11 0.16
Indoor
Unit
Indoor Air Flow
(Hi/Mi/Lo) m³/h 800/750/700 900/800/700 1100/900/750
Indoor sound pressure
(Hi/Mi/Lo) dB(A) 31/29/27 33/31/29 35/33/31
Net Dimension
(WxDxH) mm 840x840x245
Packing Dimension
(WxDxH) mm 920x920x270
Net Weight Kg 21.5 22
Gross Weight Kg 25 25.5
Panel
Net Dimension
(WxDxH) mm 950x950x50
Packing Dimension
(WxDxH) mm 1055x1055x90
Net weight Kg 6
Gross weight Kg 9
Refrigerant
Pipe
Gas Side mm/in 12.7(1/2) 15.88(5/8)
Liquid Side mm/in 6.35(1/4) 9.52(3/8)
Operation Temperature Range °C 16~31
Items Unit 80 90 100 112 125 140 160 Indoor Model: TMV-V(**)Q8/N1DY(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50/60Hz, 1Ph
Capacity
Cooling
Btu/h 27000 30000 34000 38000 42000 48000 55000
KW 8 9 10 11.2 12.5 14 16
Heating
Btu/h 30000 34000 38000 42000 48000 55000 62000
KW 9 10 11.2 12.5 14 16 18
Electric
Data
(T1)
Rated Cooling Power Input KW 0.04 0.06 0.07 0.085 0.132
Rated Heating Power Input KW 0.04 0.06 0.07 0.085 0.132
Rated Cooling Current A 0.18 0.27 0.32 0.39 0.6
Rated Heating Current A 0.18 0.27 0.32 0.39 0.6
Indoor
Unit
Indoor Air Flow
(Hi/Mi/Lo) m³/h 1300/1000/800 1500/1100/800 1600/1200/900 1800/1300/950 2100/1700/1200
Indoor sound pressure
(Hi/Mi/Lo) dB(A) 38/35/33 39/36/33 40/37/34 43/38/35 47/42/37
Net Dimension
(WxDxH) mm 840x840x245 840x840x290
Packing Dimension
(WxDxH) mm 920x920x270 920x920x315
Net Weight Kg 22 22.5 25 27.5
Gross Weight Kg 25.5 26 28.5 31
Panel
Net Dimension
(WxDxH) mm 950×950×50
Packing Dimension
(WxDxH) mm 1055×1055×90
Net weight Kg 6
Gross weight Kg 9
Refrigerant
Pipe
Gas Side mm/in 15.88(5/8)
Liquid Side mm/in 9.52(3/8)
Operation Temperature Range °C 16~31
Remark:The above designs and specifications are subject to change of product improvement without prior notice.
74 Compact Cassette
Technical characteristics
Recommended places
Office, restaurant, supermarket, shopping mall, lobby, etc
Ultra Low Noise
Using the advanced technology of three-dimensional spiral blade
design, can reduce the air resistance, realize the machine low noise
operation, \"quiet\" enjoy a comfortable life.
Built-in DC Drain Pump
The drain pump delivers a maximum lift height of 1200 mm,
simplifying installation and enabling efficient condensate drainage
from the indoor unit.
DC inverter fan motor technology
Adoption DC inverter motor technology, to improve the running
efficiency by 15% and reduce the operation noise (min 25dB)
Compact design
It features a compact body size (570mm x 570mm) that allows it to fit
neatly within the space of standard architectural ceiling tiles.
IDU Lineup & Specifications
75
Items Unit
18 22 25 28 32 36 40 45 50 56
Indoor Model:TMV-V(**)Q4R/N1D1Y(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50/60Hz, 1Ph
Capacity
Cooling
Btu/h 6000 7500 9000 10000 11000 12000 14000 15000 17000 19000
KW 1.8 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6
Heating
Btu/h 7500 9000 10000 11000 12000 14000 15000 17000 19000 21000
KW 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6 6.3
Electric
Data
(T1)
Rated Cooling
Power Input KW 0.014 0.016 0.022 0.044 0.05
Rated Heating
Power Input KW 0.014 0.016 0.022 0.044 0.05
Rated Cooling
Current A 0.06 0.07 0.1 0.2 0.23
Rated Heating
Current A 0.06 0.07 0.1 0.2 0.23
Indoor
Unit
Indoor Air Flow
(Hi/Mi/Lo) m³/h 520/390/260 560/410/280 620/460/300 750/560/310 800/590/330
Indoor sound
pressure
(Hi/Mi/Lo)
dB(A) 30/28/25 31/29/25 35/30/26 43/32/26 45/34/27
Net Dimension
(WxDxH) mm 570x570x245
Packing Dimension
(WxDxH) mm 718x657x301
Net Weight Kg 14.5 15
Gross Weight Kg 17 17.5
Panel
Net Dimension
(WxDxH) mm 650x650x57
Packing Dimension
(WxDxH) mm 734x734x95
Net weight Kg 2.7
Gross weight Kg 4.25
Refrigerant
Pipe
Gas Side mm/in 12.7(1/2)
Liquid Side mm/in 6.35 (1/4)
Operation Temperature Range °C 16-31
Compact Cassette
Specification
Notes:
1. Cooling conditions: Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Heating: Indoor temperature 20°C DB/15°C WB,and outdoor temperature 7°C DB/6°C WB
3. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber.
76 IDU Lineup & Specifications
Recommended places
Office, conference room, hotel room, restaurant, living room, etc
Technical characteristics
Low ESP Slim Duct
Constant Air Volume
Fan motor automatically adjusts speed according to real-time wind
resistance. To provide stable air volume to rooms.
Ultra-thin Body Design, Fashion and Beautiful
The minimum height of the body is only 200mm, saving space.
Segmented Slide-out Filter Design (Optional)
The filter can be pulled out from either left or right side for replacement
or cleaning, even in confined spaces.
High ESP
ESP up to 80Pa supports longer air duct and fits with more installation
scenario.
Built-in DC Drain Pump
The drain pump delivers a maximum lift height of 1200 mm, simplifying
installation and enabling efficient condensate drainage from the indoor
unit.
MAX: 12M
77
Specification
Low ESP Slim Duct
Remark:The above designs and specifications are subject to change of product improvement without prior notice.
Items Unit
18 22 25 28 32 36
Indoor Model: TMV-V(**)F5/N1DY(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50/60Hz, 1Ph
Capacity
Cooling
Btu/h 6000 7500 9000 10000 11000 12000
KW 1.8 2.2 2.5 2.8 3.2 3.6
Heating
Btu/h 7500 9000 10000 11000 12000 14000
KW 2.2 2.5 2.8 3.2 3.6 4
Electric
Data
(T1)
Rated Cooling Power Input KW 0.02 0.03
Rated Heating Power Input KW 0.02 0.03
Rated Cooling Current A 0.09 0.14
Rated Heating Current A 0.09 0.14
Indoor
Unit
Indoor Air Flow (Hi/Mi/Lo) m³/h 500/380/200 550/380/200
Indoor sound pressure
(Hi/Mi/Lo) dB(A) 30/26/20 31/26/22
External Static Pressure
(Rated) Pa 20
External Static Pressure
(Range) Pa 0~50
Net Dimension (WxDxH) mm 700×450×200
Packing Dimension (WxDxH) mm 900×555×250
Net Weight Kg 15.5
Gross Weight Kg 18
Refrigerant
Pipe
Gas Side mm/in 9.52(3/8) 12.7(1/2)
Liquid Side mm/in 6.35(1/4)
Operation Temperature Range °C 16~31
Items Unit
40 45 50 56 63 71 80
Indoor Model: TMV-V(**)F5/N1DY(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50/60Hz, 1Ph
Capacity
Cooling
Btu/h 14000 15000 17000 19000 21000 24000 27000
KW 4 4.5 5 5.6 6.3 7.1 8
Heating
Btu/h 15000 17000 19000 21000 24000 27000 30000
KW 4.5 5 5.6 6.3 7.1 8 9
Electric
Data
(T1)
Rated Cooling Power Input KW 0.05 0.054
Rated Heating Power Input KW 0.05 0.054
Rated Cooling Current A 0.23 0.25
Rated Heating Current A 0.23 0.25
Indoor
Unit
Indoor Air Flow
(Hi/Mi/Lo) m³/h 850/580/310 1100/760/480
Indoor sound pressure
(Hi/Mi/Lo) dB(A) 34/29/24 37/31/27
External Static Pressure
(Rated) Pa 20
External Static Pressure
(Range) Pa 0~50 0~80
Net Dimension (WxDxH) mm 920×450×200 1100×450×200
Packing Dimension (WxDxH) mm 1200×555×250 1290×565×245
Net Weight Kg 18 22.5
Gross Weight Kg 21 26
Refrigerant
Pipe
Gas Side mm/in 12.7(1/2) 15.88(5/8)
Liquid Side mm/in 6.35(1/4) 9.52(3/8)
Operation Temperature Range °C 16~31
78 Recommended places
Office, conference room, hotel room, restaurant, living room, etc
Technical characteristics
Free Static Pressure Duct
Ceiling & Floor installation
Support both ceiling concealed and floor
concealed installation.
Built-in DC Drain Pump
The drain pump delivers a maximum lift height
of 1200 mm, simplifying installation and
enabling efficient condensate drainage from
the indoor unit.
Magnetic Filter (Optional)
Customizable magnetic filter, no screws
required for mounting, enabling easy removal
and cleaning.
Segmented Slide-out Filter Design
(Optional)
The filter can be pulled out from either left or
right side for replacement or cleaning, even in
confined spaces.
Fresh Air
Take in outdoor fresh air, ensure that the
indoor air is fresh and circulated. Max fresh air
volume 100m2
/h.
High ESP
ESP up to 200Pa* supports longer air duct
and fits with more installation scenario.
Constant Air Volume
Fan motor automatically adjusts speed
according to real-time wind resistance. To
provide stable air volume to rooms.
Slim Body 245mm
Duct are new designed body of 245mm
thickness which is convenient for concealed
installation.
2 Air Return Ways
There are two air return ways to be chosen
for installation: bottom air return and rear air
return.
IDU Lineup & Specifications
Recommended places
Office, conference room, hotel room, restaurant, living room, etc
79
Remark:The above designs and specifications are subject to change of product improvement without prior notice.
Free Static Pressure Duct
Specification
Items Unit
45 50 56 63 71 80 90 100 112 125 140 160 180
Indoor Model: TMV-V(**)F2/N1DY(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50/60Hz, 1Ph
Capacity
Cooling
Btu/h 15,000 17,000 19,000 21,000 24,000 27,000 30,000 34,000 38,000 42,000 48,000 54,000 60,000
KW 4.5 5.0 5.6 6.3 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 17.5
Heating
Btu/h 17,000 19,000 21,000 24,000 27,000 30,000 34,000 38,000 42,000 48,000 55,000 61,000 66,000
KW 5.0 5.6 6.3 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 18.0 19.5
Electric
Data
(T1)
Rated Cooling Power
Input KW 0.072 0.125 0.18 0.23 0.28 0.33
Rated Heating Power
Input KW 0.072 0.125 0.18 0.23 0.28 0.33
Rated Cooling Current A 0.33 0.57 0.82 1.05 1.27 1.5
Rated Heating Current A 0.33 0.57 0.82 1.05 1.27 1.5
Indoor
Unit
Indoor Air Flow
(Hi/Mi/Lo) m³/h 1000/650/480 1350/950/700 1900/1400/1000 2100/1400/1050 2500/1850/1250 2700/1950/1350
Indoor sound pressure
(Hi/Mi/Lo) dB(A) 36/30/27 40/35/30 43/39/34 44/39/34 44/39/34 46/40/35
External Static Pressure
(Rated) Pa 40 50
External Static Pressure
(Range) Pa 0~160 0~200
Net Dimension
(WxDxH) mm 920×700×245 1200×700×245 1400×700×245
Packing Dimension
(WxDxH) mm 1140×830×290 1420×830×290 1620×830×290
Net Weight Kg 28 29 37 38 41 41
Gross Weight Kg 33 34 42 43 47 47
Refrigerant
Pipe
Gas Side mm/in 12.7(1/2) 15.88(5/8)
Liquid Side mm/in 6.35(1/4) 9.52(3/8)
Operation Temperature Range °C 16~31
80 IDU Lineup & Specifications
High static pressure Duct
Recommended places
Workshop, hotel, restaurant, shopping mall, ballroom,
bar and other large space places
Technical characteristics
Various Forms of Air Outlets, Matching with Decoration
The indoor unit adopts a hoiden installation mode, which can be
equipped with appropriate air outlets to perfectly combine the air
conditioning.
Ultra-high Static Pressure Design to Meet Various Space
Requirements
Maximum static pressure 300Pa, can be long distance multi-point air
supply, fully meet the air conditioning needs of different Spaces.
Clean Sterilization, Healthy Life
Built-in coarse filter, PP filter screen, optional silver ion purification
module, effectively remove large particles in the air, absorb
formaldehyde and odor, eliminate germs.
81
Remark:The above designs and specifications are subject to change of product improvement without prior notice.
High Static Pressure Duct
Specification
Items Unit
140 280 450 560
Indoor Model: TMV-V(**)F1/XFN1Y(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50Hz, 1Ph
Capacity
Cooling
Btu/h 48000 95500 153000 191000
KW 15.5 28 45 56
Heating
Btu/h 34000 68000 95500 133000
KW 10 20 28 39
Electric
Data
(T1)
Rated Cooling Power Input KW 0.42 1.1 1.55 2.25
Rated Heating Power Input KW 0.42 1.1 1.55 2.25
Rated Cooling Current A 2 5.3 7.4 10.8
Rated Heating Current A 2 5.3 7.4 10.8
Indoor
Unit
Indoor Air Flow
(Hi/Mi/Lo) m³/h 2050 3000 4000 6000
Indoor sound pressure
(Hi/Mi/Lo) dB(A) 45 53 56 60
External Static Pressure
(Rated) Pa 196 200 300
Net Dimension (WxDxH) mm 1200×590×380 1366×758×520 1770×758×700
Packing Dimension (WxDxH) mm 1410×695×435 1620×975×740 2035×975×920
Net Weight Kg 58 120 220
Gross Weight Kg 60 145 245
Refrigerant
Pipe
Gas Side mm/in 15.88(5/8) 25.4(1) 28.69(9/8)
Liquid Side mm/in 9.52(3/8) 12.7(1/2)
Operation Temperature Range °C 16~31
82 IDU Lineup & Specifications
Recommended places
Cinemas, hotels, lobbies, dance halls, bars and other places
Technical characteristics
Note: The sum of the capacity of the processing unit and the indoors should be 50%~100% of the ODU capacity, and the capacity of the fresh air units does not exceed 30%.
Fresh Air Duct
Healthy Fresh Air
Through the fresh air unit, the outdoor healthy air can be introduced
into the room to keep the indoor healthy.
Ultra-high Static Pressure Design
The maximum static pressure is 300pa, which can meet longdistance air supply and different space requirements.
Simplify Air Exhaust System
Simplified air supply and exhaust system, stable and reliable.
Control Smart and Lower Cost
The fresh air unit can be controlled independently or connected to the
same outdoor unit system with the AC indoor unit, reducing costs and
installation space.
MAX: 12M
83
Items Unit
220 280 450 560
Indoor Model:TMV-V(**)F1/N1Y(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50Hz, 1Ph
Capacity
Cooling
Btu/h 75000 96000 154000 191000
KW 22 28 45 56
Heating
Btu/h 85300 106000 171000 208000
KW 25 31 50 61
Electric
Data
(T1)
Rated Cooling Power Input KW 1.75 2.25
Rated Heating Power Input KW 1.75 2.25
Rated Cooling Current A 8.85 11.36
Rated Heating Current A 8.85 11.36
Indoor
Unit
Indoor Air Flow (Hi/Mi/Lo) m³/h 4500/3440/2910 7500/5730/4860
Indoor sound pressure (Hi/Mi/Lo) dB(A) 55/53/51 61/59/57
External Static Pressure (Rated) Pa 200
External Static Pressure (Range) Pa 100~300
Net Dimension (WxDxH) mm 1366×758×520 1770×758×700
Packing Dimension (WxDxH) mm 1620×975×740 2035×975×920
Net Weight Kg 120 220
Gross Weight Kg 145 245
Refrigerant
Pipe
Gas Side mm/in 22.2(7/8) 28.6(9/8)
Liquid Side mm/in 12.7(1/2)
Operation Temperature Range °C 16~31
Fresh Air Duct
Specification
Remark:The above designs and specifications are subject to change of product improvement without prior notice.
84 IDU Lineup & Specifications
Wall mounted
Recommended places
Living room, study, reference room, negotiation room and
other places
Technical characteristics
Ultra-low Silent Operation
Adopt large-diameter blade, high-quality plastic-encapsulated motor,
and the noise is as low as 27dB(A).
Ultra-thin Body Design, Smart and Beautiful
The minimum thickness of the unit is only 294mm, which makes
installation more convenient.
Long-lasting Filter Design
The long-term filter design makes the air more heathy, reduces the
difficulty of maintenance.
Wide-angle Air Supply, More Comfortable
The upper and lower wind guide vanes make the airflow comfortable.
27dB(A)
85
Specification (50Hz, AC)
Wall mounted (Built-in EXV)
Remark:The above designs and specifications are subject to change of product improvement without prior notice.
Specification (50/60Hz, DC)
Wall mounted (External EXV)
If the wall-mounted unit is installed in the
bedroom and you are sensitive to sounds (such
as the noise from the EXV adjustment), it is
recommended to use a external EXV kit wallmounted unit , and install the EXV kit outside the
bedroom, like in the corridor or inside the ceiling.
External EXV Kit Note: Maximum 9m if extending the EXV wire in field.
Max.3.5m
External EXV Kit
Items Unit 22 28 36 45 50 56 71 80 90 100 Indoor Model:TMV-V(**)G/N1DY-B(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50/60Hz, 1Ph
Capacity
Cooling Btu/h 7500 10000 12000 15000 17000 19000 24000 27000 30000 34000
KW 2.2 2.8 3.6 4.5 5 5.6 7.1 8 9 10
Heating Btu/h 9000 11000 14000 17000 19000 21000 27000 30000 34000 41000
KW 2.5 3.2 4 5 5.6 6.3 8 9 10 12
Electric
Data
(T1)
Rated Cooling Power Input KW 0.04 0.045 0.055 0.09
Rated Heating Power Input KW 0.04 0.045 0.055 0.09
Rated Cooling Current A 0.19 0.2 0.25 0.4
Rated Heating Current A 0.19 0.2 0.25 0.4
Indoor
Unit
Indoor Air Flow (Hi/Mi/Lo) m³/h 550/450/330 650/550/360 800/700/500 1500/1200/800
Indoor sound pressure
(S/M/Mute) dB(A) 37/29/22 39/31/27 45/38/34 47/41/36
Net Dimension (WxDxH) mm 910×206×294 1010×220×315 1186×258×360
Packing Dimension (WxDxH) mm 977×276×367 1094×300×386 1260×328×430
Net Weight Kg 9.5 12 16.5
Gross Weight Kg 12 14.5 21
Refrigerant
Pipe
Gas Side mm/in 12.7(1/2) 15.88(5/8)
Liquid Side mm/in 6.35(1/4) 9.52(3/8)
Operation Temperature Range °C 16~31
Items Unit 22 28 36 45 50 56 71 80 Indoor Model:TMV-V(**)G/N1Y-B(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50Hz, 1Ph
Capacity
Cooling
Btu/h 7500 10000 12000 15000 17000 19000 24000 27000
KW 2.2 2.8 3.6 4.5 5 5.6 7.1 8
Heating
Btu/h 9000 11000 14000 17000 19000 21000 27000 30000
KW 2.5 3.2 4 5 5.6 6.3 8 9
Electric
Data
(T1)
Rated Cooling Power Input KW 0.04 0.045 0.07
Rated Heating Power Input KW 0.04 0.045 0.07
Rated Cooling Current A 0.19 0.2 0.32
Rated Heating Current A 0.19 0.2 0.32
Indoor
Unit
Indoor Air Flow
(Hi/Mi/Lo) m³/h 550/450/350 650/580/400 800/700/550
Indoor sound pressure
(S/M/Mute) dB(A) 38/30/27 42/38/29 44/38/35
Net Dimension (WxDxH) mm 910×206×294 1010×220×315
Packing Dimension
(WxDxH) mm 977×276×367 1094×300×386
Net Weight Kg 10 13
Gross Weight Kg 12.5 16
Refrigerant
Pipe
Gas Side mm/in 12.7(1/2) 15.88(5/8)
Liquid Side mm/in 6.35(1/4) 9.52(3/8)
Operation Temperature Range °C 16~31
86 Ceiling & floor Recommended places
Living room, study, reference room, negotiation
room and other places
Technical characteristics
Ultra-thin Design
Compact design which fits for various room styles.
Detachable Plastic Blowers
Universal designed parts and assemblies applied, which is easy for
maintenance.
Flexible Installation
Wire Control (Optional)
Two ways of installation available, ceiling suspended and floor standing.
Wire control is available, especially for hotel rooms, offices, etc.
Wide Range of Air Flow
The air supply angle is from 0 to 110°, making the indoor temperature
more uniform and more comfortable.
Dual Direction of Drainage
Condensing water can be drained both from left and right side.
110°
IDU Lineup & Specifications
87
Ceiling & floor
Specification
Items Unit
45 50 56 63 71 80 90 100 112 125 140
Indoor Model: TMV-V(**)ZD/N1Y(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50Hz, 1Ph
Capacity
Cooling
Btu/h 15000 17000 19000 21000 24000 27000 30000 34000 38000 42000 48000
KW 4.5 5 5.6 6.3 7.1 8 9 10 11.2 12.5 14
Heating
Btu/h 17000 19000 21000 24000 27000 30000 34000 38000 42000 48000 55000
KW 5 5.6 6.3 7.1 8 9 10 11.2 12.5 14 16
Electric
Data
(T1)
Rated Cooling Power Input KW 0.102 0.149 0.158 0.235
Rated Heating Power Input KW 0.102 0.149 0.158 0.235
Rated Cooling Current A 0.46 0.68 0.72 1.07
Rated Heating Current A 0.46 0.68 0.72 1.07
Indoor
Unit
Indoor Air Flow (Hi/Mi/Lo) m³/h 960/870/680 1200/1100/820 1600/1440/1280 2000/1910/1590
Indoor sound pressure
(Hi/Mi/Lo) dB(A) 44/42/38 46/44/40 50/48/44 52/50/46
Net Dimension (WxDxH) mm 1055×675×235 1055×675×235 1275×675×235 1635×675×235
Packing Dimension (WxDxH) mm 1131×753×313 1351×753×313 1711×753×313
Net Weight Kg 24 25 29 38
Gross Weight Kg 27 28 35 46
Refrigerant
Pipe
Gas Side mm/in 12.7(1/2) 15.88(5/8)
Liquid Side mm/in 6.35(1/4) 9.52(3/8)
Operation Temperature Range °C 16~31
Remark:The above designs and specifications are subject to change of product improvement without prior notice.
88 One-way Cassette
Recommended places
Living room, dining room, office, lobby, etc
IDU Lineup & Specifications
Technical characteristics
Stronger Airflow
1100m3
/h large-circulation air volume ensuresrapid whole-room cooling
by circulating andspreading cool air evenly.
T-Al Energy-Saving
Using Al algorithm and tempature prediction
models, T-Al dynamically adjusts the compressor
frequency to regulate room temperature-saving
energy while keeping comfort.
High-lift Drain Pump
The drain pump with a 1200mm lifting head which is as standard,
simplifying installation of the drain pipes.
Easy Disassembly & Easy Cleaning
A simple pull-down releases the snap-fit panel
for easy maintenance and cleaning.
130mm Slim Design
Fits ceiling space as limited as 150 mm, Saves
wall-mount space, Blends in with integrated
home-style design.
10.5m Long-distance
AirflowSuitable for narrow and high-depthspaces.
Wi-Fi & OTA
Easily control your air conditioner anytime,
anywhere with just a mobile phone and update
software APP. No need to manipulate on electrical
controlboard, convenient for afterservice.
120° Wide Airflow
Full-Room Airflow adapts to diverseroom
shapes,delivering coolingcomfort that reaches
every corner.
89
One-way Cassette
Specification
Items Unit
TMV-V22Q1/
N1DY(E)
TMV-V28Q1/
N1DY(E)
TMV-V36Q1/
N1DY(E)
TMV-V45Q1/
N1DY(E)
TMV-V56Q1/
N1DY(E)
TMV-V63Q1/
N1DY(E)
TMV-V71Q1/
N1DY(E)
Indoor Model /
Power Supply V~,Hz,Ph 220-240V~50/60Hz
Capacity
Cooling kW 2.2 2.8 3.6 4.5 5.6 6.3 7.1
Heating kW 2.5 3.2 4.0 5.0 6.3 7.1 8.0
Electrical
Data
Rated Cooling Power Input W 25 25 28 30 35 45 55
Rated Heating Power Input W 25 25 28 30 35 45 55
Rated Cooling Current A 0.16 0.16 0.19 0.20 0.23 0.30 0.37
Rated Heating Current A 0.16 0.16 0.19 0.20 0.23 0.30 0.37
Indoor
Unit
Indoor Air Flow m³/h
600/550/520/
480/450/420/
390
600/550/520/
480/450/420/
390
640/590/560/
530/490/430/
400
880/790/740/
700/650/610/
570
900/820/780/
730/680/640/
590
1050/980/880/
830/740/650/
610
1100/1000/980/
880/790/700/
650
Indoor Sound Power
(Standard rating conditions) dB(A) 51/50/48/46/
44/43/42
51/50/48/46/
44/43/42
52/51/49/47/
45/44/43
53/51/50/49/
47/46/45
54/53/52/51/
49/46/45
56/55/53/51/
50/48/46
58/57/55/53/
51/49/47
Indoor Sound Pressure
(Standard rating conditions) dB(A) 37/36/34/32/
30/29/28
37/36/34/32/
30/29/28
38/37/35/33/
31/30/29
39/37/36/35/
33/32/31
40/39/38/37/
35/32/31
42/41/39/37/
36/34/32
44/43/41/39/
37/35/33
Net Dimension (WxDxH) mm 1020×450×185 1365×450×185
Net Dimensions
(no water tray) (WxDxH) mm 1020×450×130 1365×450×130
Packing Dimension (WxDxH) mm 1185×535×240 1470×540×230
Net Weight/Gross Weight kg 11.0/14.5 13.5/17.5
Panel
Net Dimension (WxDxH) mm 1180×500×90 1480×500×90
Packing Dimension (WxDxH) mm 1275x565x140 1585x575x140
Net Weight/Gross Weight kg 5.0/7.5 6.0/10.0
Refrigerant
Pipe
Gas Side mm/inch Ф9.52 (3/8'') Ф9.52 (3/8'') Ф9.52 (3/8'') Ф12.7 (1/2'') Ф12.7 (1/2'') Ф15.88 (5/8'') Ф15.88 (5/8'')
Liquid Side mm/inch Ф6.35 (1/4'') Ф6.35 (1/4'') Ф6.35 (1/4'') Ф6.35 (1/4'') Ф6.35 (1/4'') Ф9.52 (3/8'') Ф9.52 (3/8'')
Drain Pipe (External dia.) mm O.D 25
Maximum Allowable Pressure MPa 4.5
Operation Temperature Range °C 16~31
Remark:The above designs and specifications are subject to change of product improvement without prior notice.
90 Recommended places
Sitting room, study, dining room, small meeting room, etc
Technical characteristics
Two-way Cassette
IDU Lineup & Specifications
Ultra-thin Body, Lightweight Design
Super Wide Angle Air Supply
Ultra-thin body (290mm), requires less installation space, even in the
narrow low ceiling, still can be easily installed, more flexible collocation
decoration style.
Panel swing motor system adopts high-precision stepper motor, panel
up and down risk control system is more intelligent, to achieve ultrawide Angle and large range of air supply.
High-lift Drain Pump
Standard Float Switch, Water Level Monitor
A drain pump with a 700mm raise height is fitted as standard,
simplifying installation of the drain piping.
Equipped with float switch, which will automatically send alarm when
malfunction of drain pump or stuck of drain pipe occur.
Three-speed Adjustment
New winding motor, with scroll fan technology,
wider air volume regulation, quieter operation,
unique intimate wind gear design. High,
medium and low three speed adjustment,
strong refrigeration and heating, to create a
quiet and comfortable temperature.
High Ceiling Design, Direct Air Flow to
the Ground
High ceiling design, suitable for ceiling height
up to 3m space.
Quiet Design, Quiet and Comfortable
Centrifugal wind wheel, axial air inlet, through
rotation to form a certain wind pressure, small
blade area, large number, uniform air, noise
greatly reduced, for you to create a quiet and
comfortable environment.
3m
91
Two-way Cassette
Specification
Items Unit
22 28 36 45 50 56 63 71
Indoor Model: TMV-V(**)Q2/N1Y(E)
IDU Power Supply V~,Hz,Ph 220-240V, 50Hz, 1Ph
Capacity
Cooling
Btu/h 7500 10000 12000 15000 17000 19000 21000 24000
KW 2.2 2.8 3.6 4.5 5 5.6 6.3 7.1
Heating
Btu/h 9000 11000 14000 17000 19000 21000 24000 27000
KW 2.5 3.2 4 5 5.6 6.3 7.1 8
Electric
Data
(T1)
Rated Cooling Power Input KW 0.064 0.07 0.11
Rated Heating Power Input KW 0.064 0.07 0.11
Rated Cooling Current A 0.27 0.31 0.49
Rated Heating Current A 0.27 0.31 0.49
Indoor
Unit
Indoor Air Flow (Hi/Mi/Lo) m³/h 580/460/380 680/660/520 850/660/520 1360/1180/970
Indoor sound pressure
(Hi/Mi/Lo) dB(A) 42/35/32 43/38/35 44/38/35 46/39/36
Net Dimension(WxDxH) mm 1140×575×290
Packing Dimension (WxDxH) mm 1305×755×370
Net Weight Kg 32 33 34
Gross Weight Kg 38 39 40
Panel
Net Dimension (WxDxH) mm 1240×680×30
Net weight Kg 5.56
Refrigerant
Pipe
Gas Side mm/in 12.7(1/2) 15.88(5/8)
Liquid Side mm/in 6.35(1/4) 9.52(3/8)
Operation Temperature Range °C 16~31
Remark:The above designs and specifications are subject to change of product improvement without prior notice.
92 INTELLIGENT - OPERATION AND
MAINTENANCE CONTROL
TCL's full DC inverter VRF systems are equipped with intelligent operation
and maintenance capabilities. This integrated solution ensures energyefficient operation, high performance, and intelligent management for
buildings.
92 Non-polar CAN bus
communication
technology
BMS gateways
CAN Multiple control solutions
AHU AHU connection kit
BMS
VRF WiFi & APP control
solution
93
93
94 Intelligent - Operation and Maintenance Control
Remote Controller
Wired Controller
· Cooling / dehumidification / fan / heating /
automatic and other operation settings
· Temperature / fan speed setting
· Sleep/timer/swing/turbo and other functions
· Cooling / dehumidification / fan / heating / automatic and other operation
settings
· Temperature / fan speed setting
· Sleep / timer / swing / turbo and other function settings
· Monitoring function, big LCD screen displays the operation status of the unit
· Remote control signal available
Multiple control solutions
TMV6+ provides a variety control solutions for customers to choose .
4.1
Central Controller
4.2 VRF WiFi & APP control solution
86J1 86N3 86V
86B1
WiFi module
Connect the WiFi module with the air-conditioning system, and then match
the WiFi module with the wireless router through the mobile phone APP,
and the air-conditioning equipment is networked, so that the cell phone APP
can realize remote control of the air-conditioning system from a different
place and enjoy the convenience interconnection; KZH- D1
Intelligent APP
After the unit is networked, the air conditioning system can be controlled
through the Tsmart mobile APP, which can realize:
-Mode control of air conditioner cooling/heating/dehumidifying/air supply;
-Setting temperature, wind speed, timer on/off function settings;
-Single unit, group, cluster, all control;
52E 58E 85T
· 10 inches and colorful screen display, beautiful appearance, touch screem,
easy operation.
· A variety of combinations, single or multiple machines can be operated
simultaneously.
· It also has the schedule setting and historical fault query function.Up to
32 refrigerant systems and 1024 IDUs can be connected, easy to set indoor
units parameters 10'' Central Controller
95
4.4 Intelligent Control System
AHU Connection KIT
Solution to extend TCL VRF technology to
third party Air Handling Units.
√ Easy for connecting to third party AHU
√ Setting capacity by DIP
√ Remoter or wire controller can be chosen
√ 3 steps fan motor speed, Low/Mid/High
√ Error status: No error or error occurred
4.3
Communication wire Refrigerant pipe
AHU
AHU KIT
Type Condition Model Name Cooling Capacity Range
AHU
Kit
For room
return air
TMV-AK1 2.8-14 kW
TMV-AK2 16-28 kW
TMV-AK3 35-56 kW
For outside
fresh air
TMV-AKF1 2.8-14 kW
TMV-AKF2 16-28 kW
TMV-AKF3 35-56 kW
For room return air &
outside fresh air
TMV-BK1(F) 2.2-8kW
TMV-BK2(F) 9-16kW
TMV-BK3(F) 18-38kW
TMV-BK4(F) 40-56kW
TMV-BK5(F) 60-80kW
TMV-BK6(F) 90-112kW
96 Installation options
Front Front
Front Front
More than
More than
More than
IDU
ODU
First diverging pipe
IDU IDU
Guide plate
>
> >
>
>
The space shown in the figure needs to be reserved
for the installation of the ODU, and the power
supply equipment should be installed separately.
When a system has more than two outdoor
units, it is necessary to install the units as the
followings:
The outdoor units are arranged in descending
order(for example, in the right picture, ODU
capacity A ≥ ODU capacity B ≥ ODU capacity C)
and the ODU A should install at the brance pipe.
If there are stacks around the outdoor unit, the height
should be less than 800mm from the top of the
outdoor unit. If it is less than the size,a mechanical
exhaust device must be installed.
To ensure the heat dissipation of the outdoor unit,
there should be no obstacles above the outdoor
unit. If it cannot be avoided, a deflector should be
installed.
Fluorine filing valve
Liquid-side stop valve
Gas-side stop valve
(used to detect the pressure/add refrigerant
vacuumize at the time of maintenance)
Location of refrigerant pipes
Installation space for ODU
Arrangement sequence of ODU
97
Dimension of ODU
Requirements for ODU installation
Model A B
TMV-Vd+252(280)W/N1S-C(E3) 724 725
TMV-Vd+335(400/450/504)W/N1S-C(E3) 1141 725
TMV-Vd+560(615/680/730)W/N1S-C(E3) 1561 725
TMV-Vd+785(850)W/N1S-C(E3) 1700 725
TMV-VED+560(615/680/730) W/N1S-C(E3)
TMV-VED+252(280)W/N1S-C(E3) TMV-VED+335(400)W/N1S-C(E3)
1780 17801780
1780
925
1760 1900
1340
845
845 845 845
TMV6-VED+785(850)W/N1S-C(E3)
TMV-VED+450(504)W/N1S-C(E3)
A shock absorber or shock pad should be installed between the unit and the foundation.
The unit and the foundation should be released tightly, otherwise there will be a lot of noise and vibration.
The outdoor unit must be grounded reliably.
It is forbidden to open the valves of the liquid pipe, gas pipe and oil balance pipe of the unit before commission.
The installation should ensure that there is enough space for maintenance. 1780
1340
845
98 Installation options
Piping classification
Piping classification
Pipe dimension of indoor unit(NO.:a,b,c,d,… m)
Allowable length and height difference of refrigerant piping
IDU main piping and branch pipe assembly(Number: L2,L3,L4...L12,A,B,C...L)
Name of supporting pipe Connection position of supporting pipe Assembly
Main pipe Pipe between the outdoor unit and the first branch L1
Main pipe of indoor unit Pipe behind the first indoor branch which do not connect
to indoor unit L2,L3,L4,... L12
Slave pipe of indoor unit Pipes between the branch and indoor unit a,b, c, d,... m
Indoor unit branch assembly Pipes to the master pipe and slave pipes A, B, C,D,E,F,G,H, I,J,K,L
Outdoor unit branch assembly Pipes to the outdoor unit and main pipe L,Mg
Outdoor unit connecting pipe Pipe between outdoor and outdoor branch 1,g2, g3, g4, G1, G2
Indoor Unit Model Gas side Liquid side
Capacity: 1800~2200W φ9.52(flared nut) φ6.35(flared nut)
Capacity: 2800~5600W φ12.7(flared nut) φ6.35(flared nut)
Capacity: 6300~14000W φ15.9(flared nut) φ9.52(flared nut)
Capacity of
downstream
Indoor unit
A(×100w)
Dimension of
Master pipe
(Gas/Liquid)
Applicable brance
pipe
(Gas/Liquid) A(×100w)
Dimension of master
pipe
(Gas/Liquid)
Applicable brance
pipe
(Gas/Liquid)
A < 63 φ12.7/φ6.35 BY06(L01/L01) 63 ≤ A < 168 φ15.9/φ9.52 BY07(L01/L02)
168 ≤ A < 224 φ19.1/φ9.5 BY07(L01/L02) 224 ≤ A < 330 φ22.2/φ12.7 BY01(G01/L01)
330 ≤ A < 470 φ25.4/φ12.7 BY01(G01/L01) 470 ≤ A < 710 φ28.6/φ15.9 BY03(G02/L02)
710 ≤ A < 1040 φ31.8/φ19.1 BY03(G02/L02) 1040 ≤ A < 1540 φ38.1/φ19.1 BY04(G03/L02)
1540 ≤ A < 1800 φ41.2/φ22.2 BY05(G04/L03) 1800 ≤ A < 2500 φ44.5/φ25.4 BY05(G04/L03)
2500 ≤ A φ54.0/φ28.6 BY08(G05/G02)
99
Branch pipe specifications
100 Installation options
Piping classification
Piping classification
Pipe dimension of indoor unit(NO.:a,b,c,d,… m)
Allowable length and height difference of refrigerant piping
IDU main piping and branch pipe assembly(Number: L2,L3,L4...L12,A,B,C...L)
Name of supporting pipe Connection position of supporting pipe Assembly
Main pipe Pipe between the outdoor unit and the first branch L1
Main pipe of indoor unit Pipe behind the first indoor branch which do not connect
to indoor unit L2,L3,L4,... L12
Slave pipe of indoor unit Pipes between the branch and indoor unit a,b, c, d,... m
Indoor unit branch assembly Pipes to the master pipe and slave pipes A, B, C,D,E,F,G,H, I,J,K,L
Outdoor unit branch assembly Pipes to the outdoor unit and main pipe L,Mg
Outdoor unit connecting pipe Pipe between outdoor and outdoor branch 1,g2, g3, g4, G1, G2
Indoor Unit Model Gas side Liquid side
Capacity: 1800~2200W φ9.52(flared nut) φ6.35(flared nut)
Capacity: 2800~5600W φ12.7(flared nut) φ6.35(flared nut)
Capacity: 6300~14000W φ15.9(flared nut) φ9.52(flared nut)
Capacity of
downstream
Indoor unit
A(×100w)
Dimension of
Master pipe
(Gas/Liquid)
Applicable brance
pipe
(Gas/Liquid) A(×100w)
Dimension of master
pipe
(Gas/Liquid)
Applicable brance
pipe
(Gas/Liquid)
A < 63 φ12.7/φ6.35 BY06(L01/L01) 63 ≤ A < 168 φ15.9/φ9.52 BY07(L01/L02)
168 ≤ A < 224 φ19.1/φ9.5 BY07(L01/L02) 224 ≤ A < 330 φ22.2/φ12.7 BY01(G01/L01)
330 ≤ A < 470 φ25.4/φ12.7 BY01(G01/L01) 470 ≤ A < 710 φ28.6/φ15.9 BY03(G02/L02)
710 ≤ A < 1040 φ31.8/φ19.1 BY03(G02/L02) 1040 ≤ A < 1540 φ38.1/φ19.1 BY04(G03/L02)
1540 ≤ A < 1800 φ41.2/φ22.2 BY05(G04/L03) 1800 ≤ A < 2500 φ44.5/φ25.4 BY05(G04/L03)
2500 ≤ A φ54.0/φ28.6 BY08(G05/G02)