2 CONTENTS
3
Powerful cooling & heating
04
06
14
32
42
·High-efficiency scroll DC inverter compressor with EVI
·Double C high efficiency condenser
·DC inverter fan motor
·High efficiency axial fan
·36°C Three-stage supercooling technology*
·Intelligent inverter technology
·Air-cooled & refrigeration-cooled technology
·SEER
·SCOP
·\"2-1\"loop design
Authoritative attestation
DC inverter scroll compressor
High efficiency \"2-1\" refrigerant flow
0 ~ 480~Hz stepless frequency adjustment
Four seasons energy-saving mode
Variable evaporating/condensing temperature
regulation technology
Multi-priority modes, VIP priority service
R410A High-efficiency environmentally friendly
refrigerant
RoHS Certification
·Six levels oil return technology
·High precision refrigerant control technology
· Wide voltage range
· -30°C~56°C Ultra wide operating temperature range
·Pressure self-regulating technology
·Triple backup function
·Rotation function
·Multiple protections
Company Profile
26
·Intelligent Control
·Non-polar CAN bus communication technology
·Multiple control solutions
·VRF WiFi & APP control solution
·AHU connection kit
·Intelligent Control System
Intelligent-operation &
maintenance control
High efficient energy-saving
& environmental friendly
Stable & reliable performance
20
·Constant temperature
·Silent-mode
·Fresh air
·Comfortable soft wind
·Auto restart function
·Intelligent defrost technology
Comfortable & healthy
environment
Convenient Installation and
Maintenance
72 Installation options
·13 basic modules, satisfy all kind of requirement
·Super long refrigerant pipeline design
·Single system can connect 80 IDUs
·130Pa external static pressure
·Compact design and convenient transport
·One-touch commissioning function
·Non-polarity communication connection
·360°pipe connection design
·Emergency power-off function for IDU maintenance
·Commissioning software
·Auto-addressing function
48 ODU/IDU lineup & parameters
·360° Q8 cassette
·Compact cassette
·Slim duct
·Free static pressure duct
·Wall-mounted(External EXV)
·Wall-mounted(50Hz Built-in EXV)
·Wall-mounted(60Hz Built-in EXV)
·High static pressure duct
·Fresh air duct
·Ceiling & floor
·One-way cassette
·Two-way cassette
4 BUSINESS OVERVIEW
The Creative Life
TCL is a leading global tech brand in display panels, TVs, home comfort and mobile devices. Founded
in 1981, TCL operates its manufacturing and R&D centers worldwide and has products and services in
160+ countries.
At TCL, we are dedicated to improving people's lives and experiences with our innovative technology.
Our products and services aim to solve problems, bring joy to families and friends, and create a safer
and healthier world. We aspire to inspire and empower people to pursue greatness in their lives.
Air Conditioners & HVAC
Refrigeration & Laundry Appliances
Homa Refrigerators
Large-size Display & Internet Business
Mid & Small-size Display Terminals
Smart Commercial Display Terminals
Smart Connectivity
Smart Home
Photovoltaic Technology
Smart Home Appliances
Display Business
Innovative Businesses
4
5
Introduction Of TCL
TCL Corporation LTD, founded in 1981, is one of the largest consumer electronics conglomerates and
operates on a global scale in China. At present, TCL has formed four industrial groups including multimedia,
communication, China Star Optoelectronics Technology and TCL Home Appliances, and six business
segments including System Science and Technology Business Headquarters, Tikeli Group, emerging
Business Group, Investment Business Group, Hanlinhui Company and real estate. Its revenue exceeded 100
billion yuan for 5 consecutive years. The group's main industries establish R&D headquarters and 26 R &
D institutions where in China, the United States, France, Singapore and other countries. It has nearly 22
manufacturing and processing bases in China, Poland, Mexico, Thailand, Vietnam and other countries.
TCL Corporation is committed to becoming a high-tech industrial group. In January 2004, TCL was listed
in Shenzhen Stock Exchange (SZ000100). On April 16, 2019, the restructuring was officially completed.
After the restructuring, TCL owns two listed companies: Hua Xian Optoelectronics (00334.HK) and
Hanlinhui (835281). TCL Owns two listed companies: TCL Electronics (01070.HK) and Tonly Electronics
Holdings Limited (01249.HK).
After nearly 40 years of development, TCL has become a leader in the internationalization process of
Chinese enterprises by virtue of China's reform and opening-up and adhering to the enterprise spirit of
dedication and innovation.
When COVID-19 broke out In January 2020, TCL immediately rushed to Hubei, donating cash, materials
and Internet services that accumulative worth over 20 million yuan, and went to Leishenshan and other
designated hospitals to install electrical equipment. In July, TCL Technology announced that it would
become the final transferee of 100% equity of Tianjin Zhonghuan Group. TCL also carried out strategic
layout in the three industrial sectors of semiconductor display, intelligent terminal, semiconductor and
new energy. In August, TCL Technology announced the acquisition of 60 percent of Suzhou Samsung LCD
Technology Co., LTD and 100 percent of Suzhou Samsung Display Co., LTD.
In 2021, TCL Corporation annual revenue was exceed 39.4 billion dollar, significant increase in net profit.
In the same year TCL start up ‘Xuri Plan’ which invest more than 3.15 billion dollar to promote ecological
leadership and help industrial upgrading.
In the future, TCL will establish a perfect insight system that is close to consumers and run through
the overall process of corporate activities, forming the driving force of TCL brand with product force,
marketing force and experience force as the core, improving the overall brand image to the direction of
\"young, fashionable and international\", and further strengthening innovation and consumption experience.
GD TCL Intelligent Heating&Ventilating Equipment CO.,LTD. is a developmental company integrating R
& D, manufacturing, sales and service of HVAC equipment. It has achieved the full coverage of unit type
light commercial, small multi connected household central air conditioning, multi connected central air
conditioning, air-cooled modular machine series, household dual supply series, air source heat pump hot
air machine series, ultra-low temperature modular machine series, household air energy water heater series,
commercial air energy hot water series and other products. It has 4 R & D departments and 20 laboratory
groups. This year, TCL -HVAC's new base will be put into use. By then, the new and old bases will have 27
world-class production lines with an annual capacity of more than 2 million sets.
The test center of TCL -HVAC has been recognized by China National Accreditation Service for
Conformity Assessment (CNAS), which lays a solid foundation for the improvement of independent R & D
ability and laboratory management ability, as well as the establishment of a customer-centered, qualityoriented, product performance and product innovation improvement system.
With professional technology and service ability, and nearly 20 years of historical precipitation and
market accumulation, TCL -HVAC has been fully verified in the market and gained a good reputation in the
market.
TCL intelligent HVAC’s future can be expected!
Introduction Of TCL CAC
6 The TMV6+ Full DC Inverter VRF system leverages premium
components, including internationally renowned compressors,
DC motors, and high-precision EXVs. This integration of
advanced technologies enables the system to deliver superior
cooling and heating performance.
DC inverter
compressor
DC inverter
fan motor
36℃ Three-stage
supercooling technology
Intelligent inverter technology
Air-cooled & refrigenant-cooled
technology for main control board
Double C-type high
efficiency heat exchanger
High efficiency axial fan
POWERFUL
COOLING AND HEATING
6
7
7
8 High-efficiency scroll DC inverter compressor with EVI
Enhanced vapor injection technology
low fuel discharge and
reduction design
Foreign body prevention
technology
Axial flexible design
Select the material of the
high-strength pump body
High-reliability two-stage oil
supply
Asymmetric vortex line efficient oil film sealing design
High efficiency centralized coil motor
Large displacement combined
with wide frequency range
exhaust anti-reverse design Multi-stage pressure relief pump High reliability bearing design
injecting part of the gaseous refrigerant
into the compression chamber can greatly
improve the low-temperature heating
capacity and effectively reduce the exhaust
temperature.
internal optimization of oil circuit
circulation, local oil blocking
design, to achieve low oil
discharge rate;
oil pool filter, suction filter,
enthalpy increase filter, all-round
protection compressor, improve
reliability.
Using new asymmetric scroll profile, reduce leakage loss, reduce ineffective suction overheating, improving compressor efficiency.
through the back pressure
adjustment to achieve the axial
floating of the moving disc,
improve the overall reliability and
performance of the compressor;
combined with the product design
and use range, the strongest
material is QT400 to ensure the
combined with centrifugal oil supply reliability of the monomer;
and differential pressure oil supply,
to ensure the full lubrication of each
friction under different speeds and
different controls;
hydrodynamic lubrication, oil
film sealing of the compression
chamber, effectively reduce
friction, improve performance and
reliability;
select asymmetric line to
effectively reduce overheating
losses and leakage losses, and
improve the efficiency of the unit;
excellent groove design, to ensure the
energy efficiency of each frequency;
speed range 14~160rps,
displacement up to 96cc, strong
power, expand the scope of usage.
exhaust valve adopts check
valve to effectively prevent liquid
compression and improve the
reliability of working conditions
with liquid;
all three bearings are PTFE coated
plain bearings with low noise and
vibration to ensure long-term
reliability;
dynamically adjust the intermediate
pressure according to the operating
conditions to prevent overcompression under low compression
ratio and improve the operating
efficiency of low load;
1.1
1
2
3
4
5
6 7 8
9
1
2
3
4
5
6
7
8
9
10
12
13
11
10
11
12
13
Powerful Cooling and Heating
9
Dual-Mode Enthalpy Enhancement Technology
Our Dual Enthalpy Enhancement Technology ensures exceptional performance in extreme conditions, providing strong cooling
at 56°C and powerful heating at -30°C.
It intelligently manages refrigerant flow in both modes. In cooling, it increases circulation and subcooling to prevent noise after
long pipe runs. In heating, it injects vapor into the compressor to boost refrigerant flow when outdoor temperatures plummet.
This results in a reliable, stable system capable of effective heating even at very low temperatures.
>>
>>Asymmetric vortices
In view of the high pressure characteristics of R410A refrigerant, the compressor
strengthens the bearing structure and adopts the design of asymmetric scroll
disk, which has the following advantages over the symmetrical scroll disk:
Reduce refrigerant leakage and improve efficiency;
Two adjacent chambers have small pressure difference, small
vibration and more mute;
Prevent over compression, prolong the service life of the compressor.
Motor rotor with neodymium magnetic material
Neodymium, an artificial permanent magnet, is one of the strongest
magnetic materials to date. The magnetic force of neodymium
magnet is 10 times that of common ferrite magnet. Under the same
volume, the electromagnetic field intensity is stronger, the starting
torque is larger, and the operation efficiency is higher.
>>
Neodymium Magnets Ferrite Magnet
Enhanced Vapor Injection (EVI) with Two-Stage Compression
Refrigerant circulation
is increased through
vapor injection.
Enthalpy
The evaporation capacity of the ODU is enhanced
m+ △ mm Increase in refrigerant flow
Air jet + gas
Pressure
Traditional VRF
Enthalpy
Gas
Pressure
Enhanced Vapor Injection (EVI) Compressor
Main throttle valve Plate heat exchanger
Auxiliary throttle valve
Increase refrigerant circulation
Enhance the indoor unit capacity
Enhanced Vapor Injection (EVI) Compressor Improve the degree of supercooling, strengthen the evaporation capacity
10 The Double C-type compact heat exchanger features a super-large surface area. This design not only increases
heat exchange efficiency but also reduces system pressure loss, resulting in superior performance under heavy-load
conditions.
*Note : Only for 28HP and above.
This new structural design optimizes system performance under partial loads while
minimizing the unit's overall footprint.
32HP occupies only 1.6055m2
, which is 21.4% less than the previous generation
Heat exchanger adopts the perfect combination of multi-coated hydrophilic aluminum foil heat exchange fins
and high-efficiency internally threaded heat exchange copper tubes, which greatly improves the heat exchange
efficiency and enhances the corrosion resistance and oxidation resistance of the heat exchanger.
The internally grooved surface of the
copper tube increases the refrigerant's
surface area contact, directly enhancing
the heat exchanger's thermal conductivity
and overall performance.
The use of multiple rows of smalldiameter tubes with reduced
spacing increases the tube count
per unit length, thereby significantly
expanding the heat exchange area
and boosting efficiency.
The hydrophilic aluminum foil promotes condensate to form a thin, rapidly draining
film instead of discrete water droplets. This increases the effective heat exchange
area, accelerates the rate of heating and cooling, and eliminates acoustic noise
caused by airflow obstruction.
φ7 Heat Exchange Copper Tube Internally threaded copper tubes
Lubricating layer
By breaking the surface tension
of water, the system ensures rapid
d ra i n a g e o f c o n d e n s a t i o n a n d
meltwater. This minimizes the insulating
effect of water lingering on the coils,
leading to enhanced heat transfer and
increased cooling capacity.
Ensure that the air conditioner is not
easy to form frost when heating.
The heat exchanger is designed to resist
corrosion from aggressive gases.
Hydrophilic coating
Corrosion resistant coating
fins
Hydrophilic aluminum fin
32HP
Reduction from
the TMV6+S
21.4%
Powerful Cooling and Heating
This new structural design optimizes system performance under partial loads while
1.2 Double 'C' type heat exchanger*
Double C-Type heat exchanger Traditional VRF
11
High voltage (concentrated coil) DC motor
750mm Large size axial fow fan
The outdoor unit fan motor adopts a high-voltage
centralized winding DC motor, which has a more stable
and reliable output, effectively reduces losses and
improves operating efficiency.
Reduced coil height, reduced copper loss, higher
efficiency in low and medium speed zones.
The outdoor unit fan adopts φ750mm super-size wind wheel, compared with ordinary air conditioner φ540mm
dual fans, it has sufficient air volume, higher heat exchange efficiency and lower noise.
The fan is steplessly adjusted according to environmental conditions and air-conditioning load conditions, and is
matched with the compressor's stepless frequency conversion technology, so that the system runs more stable and
reliable.
Fan speed Stepless speed regulation
Low
High
1.Accurately adjust the refrigerant pressure to
improve the reliability of the unit;
2. The motor speed is adjusted quickly to better
adapt to the rapid changes in air-conditioning load.
Average speed
90Hz
0
1.3
1.4
750mmSuper size fan
+
φ φ 540mm Common dual fans φ 540mm Common dual fans
VS
Concentrated coil motor
Improve motor efficiency
And reduce motor noise
Neodymium magneto rotor
The original rotor The new rotor
12 This design elevates heat exchange performance by integrating a 3-stage sub-cooling cycle—which increases the
unit mass refrigeration capacity and lowers flow resistance—with an electronic expansion valve that delivers precise,
stable control.
When the outdoor environment is35 ℃ , the outlet refrigerant of the heat exchanger is cooled to 37.1 ℃ , and the
primary and secondary supercooling can achieve degree of 11.2℃ .
A high-efficiency plate heat exchanger is employed as the secondary subcooler to cool the 37.1°C refrigerant
down to 36°C. This subcooling process reduces refrigerant flow resistance, which in turn enables the use of longer
piping runs. These improvements collectively contribute to higher system energy efficiency, enhanced cooling and
heating performance, and increased overall reliability.
Common
Refrigerant cooling temperature at 35℃ Condenser + supercooler
Plate heat exchanger Schematic diagram of plate heat exchangercirculation
TCL
Normal temperature and
high pressure refrigerant
Low temperature and
low pressure refrigerant
Temperature
Drop
1 1.2°C
Pressure
Enthalpy
* Note: Applicable to some models
Powerful Cooling and Heating
First
Second
Supercooled liquid
refrigerant
Gas liquid two phase
mixing state
Gaseous
Refrigerant
compressor
ODU IDU
Heat exchanger The first stage
of supercooling
The third stage
of supercooling
Heat exchanger
Secondary supercooling
1.5 3-Stage sub-cooling technology to achieve 36°C sub-cooling
13
Intelligent Inverter
Surrounding refrigerant cooling technology
The unit uses multiple sets of high-precision, high-efficiency and high-reliability intelligent
inverters to control the compressor and fan motors, making the control more flexible, efficient and
intelligent.
The outdoor unit's inverter module is cooled by refrigerant to ensure that the inverter module can
be effectively cooled in a high-temperature environment, reduce the working temperature of the
module board, and improve the reliability and service life of the electronic control system. It also
prevents poor heat dissipation under extreme conditions, such as due to the periodic stop of the
fan.
1.6
1.7
80°C
60°C
The wraparound refrigerant radiator can stably and efficiently take away the
heat in the frequency conversion module of outdoor unit, improve the electrical
reliability of the unit when working in high temperature environment, and
ensure stable and safe operation.
+
The heat dissipation plate is fitted 360°
tightly with the refrigerant tube, effectively
reducing the contact thermal resistance
between the copper tube and the heat
dissipation plate, and the heat dissipation
performance is superior.
Air cooling heat dissipation
Electric control system
Enhanced fan ventilation improves
cooling to ensure stable and reliable
system operation.
Refrigerant radiator
The cooling plate
Refrigerant pipe
Temperature drop
Intelligent inverter
1.Suppresses high-order harmonics and torque fluctuation
to achieve lower vibration and quieter operation.
2.Enables smooth starting by reducing inrush current,
thus minimizing grid impact and widening the
compressor's operational frequency band.
3.Maintains stable performance within a 243V-460V
voltage range, ensuring reliability under fluctuating power
conditions.
4.Features comprehensive safeguards against electrical
and thermal faults to protect system integrity and ensure
continuous operation.
14 The global climate is facing severe challenges, in order to achieve the
\"dual carbon\" goal, it has become an urgent issue for enterprises to
control carbon emissions effectively, improve energy efficiency and reduce
energy consumption. TCL CAC follows the product design concept of high
efficiency, energy saving and low carbon, use high-quality components
of efficient refrigeration and leading refrigerating technology, to achieve
building air-conditioning systems Integrate the goal of green, reliable and
efficient energy management.
HIGH EFFICIENT
ENERGY-SAVING AND
ENVIRONMENTAL FRIENDLY
14 Stepless inverter
technology RoHS certification
Variable evaporating/condensing temperature
adjustment technology
R410A refrigerant High energy-efficient
compressor
15
15
16 High Efficient Energy-saving and Environmental Friendly
SCOP
TMV6+ full DC inverter intelligent VRF product, its seasonal energy efficiency ratio is up to 7.28, seasonal coefficient
of energy is up to 4.49
TMV6+
TMV6+
2.2
SEER
SCOP
4.50
7.35
4.00
2.00
5.00
3.00
6.00
4.00
7.00
5.00
4.45
7.26
4.40
7.05
4.42
6.75
4.39
6.25
4.40
6.61
4.35
6.41
4.30
6.20
4.28
6.26
4.20
6.16
4.20
5.97
4.50
6.50
4.16
5.50
28HP
28HP
30HP
30HP
32HP
32HP
2.1 SEER
17
DC inverter scroll compressor
Authoritative attestation
High efficiency \"2-1\" refrigerant flow
The TMV6+ series full inverter VRF units, through
the compressor core frequency conversion
technology upgrade, the overall optimization of
the refrigeration system and the control system,
makes the unit energy-saving performance even
better, and has passed the Eurovent and CE
standard certification.
The gas-liquid mixed phase refrigerant offers superior heat transfer efficiency compared to purely gaseous or liquid
phases. This circuit is designed to maximize this advantage by simultaneously increasing both the proportion of liquid
refrigerant and its flow velocity, thereby significantly enhancing the overall heat exchange effectiveness.
Gaseous
Refrigerant
Gas-liquid
mixed phase
Liquid
Refrigerant
2.3
2.4
2.5
Common
2-1
Raise the liquid refrigerant in the heat
exchanger
To improve the heat transfer
efficiency
The DC variable frequency compressor adopts an asymmetric scroll structure to effectively reduce the leakage
loss of refrigerant gas during suction and inside the compression chamber, to improve the efficiency and reliability
of compressor operation.
Optimized asymmetric vortex line Suction directly
Concentrated winding motor Intermediate pressure servo mechanism
Using new type of asymmetric scroll profile can reduce
leakage loss and ineffective suction overheating, which
improves compressor efficiency.
Small suction preheating, high volume
efficiency
The intermediate pressure is dynamically
adjusted according to the operating pressure
to achieve axial flexibility, optimize the
orbiting and fixed scroll teeth, and improve
product performance.
The coil height of the concentrated winding motor is
reduced, the copper loss is less the efficiency is higher
in the middle and low speed areas.
Gaseous
Refrigerant
Liquid
Refrigerant
Gaseous
Refrigerant
Liquid
Refrigerant
Gas phase Liquid Gaseous
Refrigerant
Gas-liquid
mixed phase
Liquid
Refrigerant
18 The operating speed of the DC inverter compressor can be adjusted continuously and freely according to the change
of the system capacity. The accuracy is higher, the stepless frequency conversion is realized, and the sub-adaptive
control technology is combined, and the capacity output is automatically adjusted according to the actual control
load to ensure a higher level of accuracy. Smooth change curve to meet higher demands for comfort. TCL 's TMV6+
can only use broadband compressors and powerful inverter control motherboards for multiple connections. The
compressors operate at 0-480Hz broadband, which has more capacity and can better cope with various complex and
harsh extreme conditions.
The unit has industry-leading EER and Integrated Part Load Value IPLV (C)
480
10
Frequency(Hz)
Infinitely
Adjustable-speed
Multistage
Regulation
High Efficient Energy-saving and Environmental Friendly
2.6 0~480Hz stepless frequency adjustment
Select the automatic energy-saving mode, the system optimizes
output according to changes in ambient temperature, realizes
automatic control of energy-saving in all seasons, and improves the
overall energy efficiency of the unit's all-season operation.
2.7 Four seasons energy-saving mode
The compressor adopts 180° sine wave vector drive
technology, which can obtain an ideal smooth sine wave
curve, so that the motor runs smoothly, the electric energy
efficiency is higher, and the harsh sound is reduced.
Vector control technology effectively
suppresses high magnetic harmonic current and
electromagnetic noise, and has passed the national
EMC electromagnetic interference test
common
time time
current current
voltage voltage
Rectangular
wave
Rectangular
wave
TCL
19
Variable evaporating/condensing temperature regulation technology
R410A High-efficiency environmentally friendly refrigerant
Multi-priority modes, VIP priority service
RoHS Certification
The self-adaptive adjustment of evaporating and condensing temperature can ensure that when the air conditioner is
running, the refrigerant flow can be accurately controlled according to the demand, and the evaporating/condensing
temperature can be automatically adjusted to reduce temperature fluctuation, to achieve the effect of energy saving
and constant temperature.
Too hot
±0.5℃
Difference in temperature big
26℃
Too cold
26°
TMV6+
Time Ordinary
R410A is an HFC refrigerant that does not damage the ozone layer. Using
R410A can increase the COP and protect the ozone layer. It is an efficient and
environmental- friendly refrigerant.
The TMV6+ system can be set with a variety of operating modes, cooling only/heating only/cooling priority/heating
priority/VIP priority/first opening priority to prevent mode conflict.
TMV6+ full inverter VRF unit is highly efficient
and environmentally friendly. Seiko builds global
quality and has passed EU RoHS certification.
R410A is non-toxic and is a \"non-flammable refrigerant\".
2.8
2.10
2.9
2.11
Response only VIP priority
coolong
Respond only
heating
Cooling priority Heating priority
Hot
Cold
20 The demand for healthier indoor environments is rising, making
superior air quality in buildings a key priority. In response, TCL's
intelligent VRF systems are pursuing innovation to deliver
comfortable, clean, and healthy air—elevating everyday living to a
higher standard.
Extreme fast
cooling and heating
Silent-mode
Constant
temperature
COMFORTABLE AND
HEALTHY ENVIRONMENT
Fresh air
Comfortable
soft wind
Intelligent defrost
technology
Auto restart
function
20
21
21
22 Multiple sensors detect the real time temperature of the system to make sure the indoor temperature fluctuation
within ±0.5°C.
The outdoor unit has multiple electronic expansion valves which can adjust the refrigerant circulation and control the
compressor overheat accurately to get a precise temperature control.
Can detect accurate temperature
with precision ±0.5°C
This technology is mainly used to increase the refrigerant flow and improve the cooling effect when the indoor side
refrigerant flow is insufficient.
High precision and sensitivity can
detect the pressure fluctuation
quickly and accurately.
Multi-electronic expansion valves
High-precision temperature sensor
Refrigerant liquid by-pass technology
Dual pressure sensors
Electronic expansion valve
Comfortable and Healthy Environment
Refrigerant pipe
Supercooled
electronic
expansion valve
Electronic
expansion valve
for heating
Check valve
filter
supercooler
Automatically open/close
Electronic
expansion valve
Electronic
expansion valve
Max. 80 IDU
Check valve
3.1 Constant temperature
23
Multiple silence technology
The structure of each component is involved in optimized airflow analysis, which can not only operate with low
noise, but also ensure the air volume and operation effect of the outdoor unit.
3.2
noise
Ability
Load
Volume
IDU total load
Standard model
Silent night
Ultra silent operation
Common CAC
13 items of silent improvments
The outdoor unit can automatically detect and record
periods of peak ambient temperature. Once triggered, it
initiates a silent mode after an 8-hour delay. This mode
operates for 10 hours, maintaining a noise level as low as
45 dB(A) before the system reverts to normal.
In this mode, the running noise of the system will be
reduced to be 40dB(A).
Night mode Enable
Night mode
Peak outdoor
temperature
End
Night mode
8hrs 10hrs
Minimum reduction
15dB(A)
New designed
compressor with less
vibration and low
noise.
The upgraded pipe system design reduce pipe
system vibration at most.
3D simulation design with less
noise and vibration.
Sub cooling design can reach
to 36°C of the refrigerant
temperature to reduce the
noise of the piping system
Lower noise scroll
compressor
3
Stepless fan speed
control with less
vibration design.
2 Inverter fan motor
Adopt 4 biger size fan blades and CFD simulation
design to get bigger air volume, reduce the noise.
13 Fan blade design
The metal panels have
stronger strength to
reduce noise
Higher air volume, less
noise and vibration.
1 Air outlet grill
9
Built-in air guide design
reduce air resistance and
reduce noise effectively
12 New design of wind guide
Refrigerant flow noise
silencing treatment
Double-layer insulation
for compressor.
Jet silencer design
Sub-cooling technology
Rubber pads fix the
pipes
3D simulation chassis design 3D simulation pipe design
4 7
8
11
10
5 6
Reduce pipeline structure
noise and vibration
Night silent mode Super silent mode
24 TCL VRF can supply the multiple fresh air solutions such as fresh air processing units and air handing units etc.
The upgraded panels have a beautiful apperance and provide comfortable air supply .
Intake fresh air to indoor Fresh air
Discharge the dirty air
Dirty air
>>>>>>
Comfortable and Healthy Environment
>>>>>>
3.3 Fresh air solution
3.4 Comfortable soft wind panel (optional)
25
Intelligent defrost technology
Intelligent auto-restart function
In the event of a sudden power outage, the system automatically saves the unit's status prior to the shutdown. Once
power is restored, it resumes operation to the pre-shutdown state (including operating mode, set temperature, fan
speed, etc.) without requiring manual reconfiguration, delivering smarter service.
Note: This function can also start manually
The system can automatically decide the time to defrost according to the operation data and heating capacity.
Under high humidity condition, the system will defrost in advance to keep the room comfortable.
During defrosting, the system will shut off the indoor to avoid the cold air .
3.5
3.6
Common defrost Defrost Defrost
Defrost
Defrost Defrost
Defrost
Heating
operation
Heating
operation
Reduce
defrosting tims
Reduce
defrosting time
Reduce
defrosting time
Reduce
defrosting times
Heating
operation
Heating
operation
Heating
operation
Heating
operation
Heating
operation
TCL Intelligent
defrost
Defrosting without stop,
reduce defrosting time and times
Common defrost Heating capacity
Intelligent defrost Time
26 Non-polar CAN bus
communication
technology
VRF WiFi & APP control
solution
BMS gateways
Multiple control solutions
INTELLIGENT - OPERATION AND
MAINTENANCE CONTROL
CAN
AHU AHU connection kit
BMS
TCL's full DC inverter VRF systems are equipped with intelligent operation
and maintenance capabilities. This integrated solution ensures energyefficient operation, high performance, and intelligent management for
buildings.
26
27
27
28 4.1
During installation, the system automatically detects the number of indoor and outdoor units, communication
link status, and real-time feedback of installation abnormalities, making installation simple and easy.
Smart commissioning
When the equipment is running, the system record the best running status intelligently . And it will adjust the
compressor frequency and the step of the EXV for next time automatically .
Intelligent detection
Intelligent - Operation and Maintenance Control
Intelligent Control
29
During system operation, data will be recorded , abnormalities will be automatically detected and raised.
Smart detection
Non-polar CAN bus communication technology
TMV6+ adopts CAN bus communication technology, which is a communication technology applied in the field of
automobile and military industry.
4.2
TMV6 VRF(CAN communication) Other similar products in the industry(RS 485
communication)
Reliability High reliability and stable network The reliability is unstable and easy to be paralyzed
Communication
efficiency Up to 100kbs About 10kbs
Communication distance About 2000m About 1000m
Communication line
polarity No polarity, easy to debug Polarities need to be distinguished for installation
Scalability Easy to plug and play To add new device, the software must be changed,
and the scalability is poor
Wire control
Remote control
Packet controller
Centralized controller
Network centralized
control system
Intelligent building
control system
BMS
Intelligence
extensions
30 Intelligent - Operation and Maintenance Control
Remote Controller
Wired Controller
· Cooling / dehumidification / fan / heating /
automatic and other operation settings
· Temperature / fan speed setting
· Sleep/timer/swing/turbo and other functions
· Cooling / dehumidification / fan / heating / automatic and other operation
settings
· Temperature / fan speed setting
· Sleep / timer / swing / turbo and other function settings
· Monitoring function, big LCD screen displays the operation status of the unit
· Remote control signal available
Multiple control solutions
TMV6+ provides a variety control solutions for customers to choose .
4.3
Central Controller
· 7/10.1 inches and colorful screen display, beautiful appearance, touch screem,
easy operation.
· A variety of combinations, single or multiple machines can be operated
simultaneously.
· Up to 16 systems and 1280 indoor units can be connected, easy to set indoor
units parameters.(7 inch)
· It also has the schedule setting and historical fault query function.Up to 32
refrigerant systems and 1024 IDUs can be connected, easy to set indoor units
parameters(10.1 inch)
Central controller 10'' Central controller
4.4VRF WiFi & APP control solution
86J1 86N3 86V1
WiFi module
Connect the WiFi module with the air-conditioning system, and then match
the WiFi module with the wireless router through the mobile phone APP,
and the air-conditioning equipment is networked, so that the cell phone APP
can realize remote control of the air-conditioning system from a different
place and enjoy the convenience interconnection; KZH- D1
Intelligent APP
After the unit is networked, the air conditioning system can be controlled
through the Tsmart mobile APP, which can realize:
-Mode control of air conditioner cooling/heating/dehumidifying/air supply;
-Setting temperature, wind speed, timer on/off function settings;
-Single unit, group, cluster, all control;
52E 58E 85T
31
4.6Intelligent Control System
AHU Connection KIT
Solution to extend TCL VRF technology to
third party Air Handling Units.
√ Easy for connecting to third party AHU
√ Setting capacity by DIP
√ Remoter or wire controller can be chosen
√ 3 steps fan motor speed, Low/Mid/High
√ Error status: No error or error occurred
4.5
Communication wire Refrigerant pipe
AHU
AHU KIT
Type Condition Model Name Cooling Capacity Range
AHU
Kit
For room
return air
TMV-AK1 2.8-14kW
TMV-AK2 16-28kW
TMV-AK3 30-56kW
For outside
fresh air
TMV-AKF1 2.8-14kW
TMV-AKF2 16-28kW
TMV-AKF3 30-56kW
For room return air &
outside fresh air
TMV-BK1(E) 2.2-8kW
TMV-BK2(E) 9-16kW
TMV-BK3(E) 18-38kW
TMV-BK4(E) 40-58kW
TMV-BK5(E) 60-80kW
TMV-BK6(E) 82-112kW
32 Built on a foundation of advanced manufacturing and deep
technical expertise, TCL's commitment to quality is embodied in
our VRF systems. They are engineered to deliver stable, efficient,
and reliable performance, even under complex and variable
operating conditions.
Inverter module cooling
protection technology
High precision refrigerant
control technology
Pressure self-regulating
technology
Six levels oil return
technology
-30°C ~ 56°C
Ultra wide operating
temperature range
Triple backup function
Rotation function Multiple protections
STABLE AND RELIABLE
PERFORMANCE
32
33
33
34 5.1 6-Stage oil return technology
The VRF system have sufficient and balanced oil in working condition to ensure safety and avoid
potential oil shortages.
Oil balancing system improves compressor
oil storage and reliability, which also ensures
the unit in good performance in cooling /
heating mode.
TMV6+ is at the leading position on the oil separate, oil return, oil balance and storage technology. The oil system
equipped with precise 6 grade management to make sure compressor safety, stability and reliability.
Multistage Oil Control Technology
Automatic oil balancing
Level 1
Level 6
Oil /Mist separation
Oil block points
Centrifugal separation
Gravity separation
Efficiency off oil separation:99%
Intelligent oil
balancing control
Low pressure sensor
+
+
+
Stable and Reliable Performance
Oil return from the distributor
ODU.1
Gaseous separation gas
ODU.2
Gaseous separation gas
Level 1: Compressor internal oil separate
Level 2: Compressor external oil separate
Level 3: High-efficiency centrifugal oil separator
Level 4: Oil balance pipes between compressors to ensure compressors running normally
Level 5: Automatic oil balance system improves the compressor reliability
Level 6: Smart oil return program to ensure the oil return completely
Level 1
Oil return from the distributor
Level 2
Level 3
Level 4
Level 5
35
5.2 High precision refrigerant control function
The upgraded technology allows the system to manage the volume of refrigerant,and also reduct the refrigerant in
entire system and increase efficiency.
Liquid bypass control technology use multi-electronic expansion valve, it can adjust the refrigerant flow and control
the overheating degree of the compressor, ensure the compressor to be highly efficient, safety and reliable.
Automatically open/close
Electronic
expansion valve
Silent electronic expansion valve used for
indoor unit, precisely control refrigerant flow,
improve the comfort and reliability.
Electronic
expansion valve
Electronic
expansion valve
Electronic
expansion valve
Max. 80 IDUs
Check valve
5.3 Wide voltage range
The unit can operate in the range of
voltage 290V~460V (International
standard voltage 380V±10%),satisfy
all kinds of voltage conditions.
290V
460V
International Standard
342~418V
36 5.5 Pressure self-adjustment technology
Pressure sensor is used to check system pressure, and adjust compressor operation frequency, fan speed, electronic
expansion valve, to ensure the system with the best performance
High pressure sensor Cold suspected device
Low-pressure sensor feedback
the suction pressure, so the
unit can adjust quickly, to
ensure the high stability of the
system.
Compare system pressure
with the best pressure value
per five seconds, and adjust
the motor speed in time.
Monitor high pressure changes,
protect compressor from the
impact of pressure suddenly
change
Low pressure sensor
Evaporator
EXV
High pressure sensor
Low pressure sensor Adjust motor speed
High pressure sensor
Low pressure sensor
Stable and Reliable Performance
5.4 Wide operation temperature range -30°C ~ 56°C
Wide operation range, cooling:-15°C~56°C, heating: -30°C~28°C.
-20 -10 0 10 20 30 40 50 60 70 °C
-15°C 56°C Cooling
-50 -40 -30 -20 -10 0 10 20 30 40 °C
-30°C Heating 28°C
37
5.6 Triple back-up operation technology
In units with two compressors, if one compressor fails, the other compressor can run on its own, to ensure the air
conditioning system can work stably.
In a multi-unit system, if one outdoor unit fails, the other modules provide backup so that the system can continue operating.
Running state
Standby
Failure or shutdown status Running state Emergency operation
Emergency operation
Compressor backup operation
ODU backup operation
When one fan motor fails, another motor can
still run, to ensure the stable system operation.
Fan back up operation
Running state Running state Running state Running state Error Running state
Running state
38 Stable and Reliable Performance
Priority
Priority
Priority
Priority
3
3
3
4 3
4
4
2 4
2
2
1 2
1
1
1
Rotation operation technology
Multiple protection functions
5.7
5.8
If the system is connected to multiple modules, in order to ensure the balance of compressor operation, the
automatic control of the microprocessor on the host can realize the automatic rotation operation function
between the modules, effectively extend the service life of the unit.
Multiple protection functions to ensure the safe operation of the system.
Module Rotation
Fan
anti-reverse
Phase sequence
protection
Lightning
protection
High voltage
protection
Low voltage
protection
Anti-freeze
protection
Current
protection
Harmonic
suppression
Phase
protection
Anti-electromagnetic
interference protection
Temperature
protection
Pressure
Protection
Compressor overload
protection
Motor overheating
protection
Safety grounding
protection
This function balances the operating hours across all unit
compressors, promoting even wear to significantly extend
their service life. (Applicable to dual-compressor units).
Compressor Rotation
39
The external force blows
the outdoor unit fan to
rotate in reverse. At this
time, start and stop the
rotation of the fan, and
then restart the fan motor
in a forward rotation
according to the normal
procedure, so as not to
damage the fan motors
due to excessive starting
current.
An external force causes the fan to
rotate in the opposite direction
An external force causes the fan to
rotate in the opposite direction
Start the unit and stop running Positive rotation, low starting
torque, protect the fan blade
Instant reverse rotation, torque suddenly increased,
easy to cause fan blade damage
When the power cord of the outdoor unit is connected incorrectly,
the circuit will start self-protection to avoid impact and damage to
the main control board, inverter module and compressor. Ensure the
normal operation of the air conditioner, without accidental electrical
damage, fire, etc.
Automatically recognize the working voltage, when the voltage is too low, give an early warning in time, and
control the power consumption and capacity output of the multi-line system through the corresponding limit
frequency.
The outdoor unit has a builtin anti-seismic module, which
has anti-seismic and antiinterference functions to ensure
the safe and stable operation of
the system in bad weather.
When the compressor casing or
motor temperature is too high,
the circuit will automatically cut
off to prevent the compressor
from overloading and cause
electrical damage, fire, etc.
When the current exceeds the
set value, the temperature will
rise, and the motor will be cut
off in time during overcurrent
operation to protect the motor
from burning due to overload.
Anti-adversity function
Phase sequence protection
Low voltage recognition function
Lightning protection Compressor overload protection Motor overheating protection Against the wind Often gauge
L1 L2 L3 N
40 5.9 Anticorrosion design
It adopts anti-corrosion and anti-oxidation
hydrophilic aluminum foil heat exchange fins,
which have multiple protections of lubricating
coating, hydrophilic coating and corrosionresistant coating.
Improve the protection level of the motor. The
motor shaft is made of stainless steel. During the
installation process, the motor shaft, nuts, gaskets
and exposed motor shaft are coated with anti-rust
grease, and the motor body screws and top cover
screws are coated with silicone grease.
The main board is equipped with moisture-proof glue,
the sheet metal surface of the electric control box is
treated with anti-corrosion spray, and the top of the
metal casing fan capacitor is sprayed with anti-corrosion
paint separately.
The nails, nuts and washers are made of stainless
steel or high anti-corrosion materials, and the
screw heads inside the machine and outside the
electric control box are coated with silicone grease
for anti-corrosion.
It adopts surface phosphating treatment with good
anti-corrosion performance.
The surface of the sheet metal parts is phosphated
and coated with special anti-corrosion materials.
It improves the salt spray resistance and heat and
humidity resistance, and greatly improves the anticorrosion ability of the sheet metal.
Use special anti-corrosion coils. The base layer
of ordinary galvanized sheet is increased with
electrophoretic layer to achieve anti-corrosion
effect. The coil fixing screws are stainless steel
screws.
Hydrophilic aluminum fin
Motor protection upgrade
Electric control anti-corrosion Fastener
Pressure vessel
Thick sheet metal design
Special corrosion-resistant coil
Phosphating
Silicon grease
Lubrication layer Hydrophilic coating
Corrosion resistant coating
Stable and Reliable Performance
41
5.10 Electronic control board SMT placement technology
The electronic control main board adopts SMT patch sealing technology to improve the anti-clutter interference,
to ensure that the main board is not affected by wind, sand, high temperature and high humidity, and to make the
main control board longer.
SMT
CPU
Anti-snow function
Fault self-check
5.11
5.12
In the snowy weather conditions in winter, in order to prevent the snow from adversely affecting the top of the
outdoor unit fan,you can turn on anti-snow mode, the fan starts running to clear the snow to ensure the normal
operation of the unit.
TMV6+ series DC inverter intelligent VRF are equipped
with electronic control fault self-diagnosis function,
which can accurately locate the faulty parts and display
the fault code when a fault occurs, thus improving the
maintenance efficiency.
42 The TMV6+ is designed for diverse application scenarios, with its
installation environment requirements carefully considered. Its appearance
and functional design incorporate user-centric details that significantly
enhance installation convenience, accelerate the process, and simplify
future maintenance.
CONVENIENT INSTALLATION
AND MAINTENANCE
42 Super long refrigerant
pipeline design,
flexible structure
1100 Convenient for the transportation,
installation and commissioning
Big-capacity module design, easy
installation and space saving
130Pa The highest static
pressure for outdoor
unit
15 basic modules, satisfy
all kind of requirement
Commissioning software
Auto-addressing
function
Emergency power-off
function for indoor unit
maintenance
43
43
44 6.1 Intelligent multi-connection, easy to cope with the spatial layout
Our system is engineered to meet the exact needs of any building type. It features 13 scalable outdoor unit modules
(8-32 HP) that can be seamlessly combined to create powerful systems up to 128 HP. With a vast selection of over
100 indoor models across 9 categories (max 56 kW), our solutions offer ultimate flexibility. A single system can
integrate up to 80 indoor units, enabling fully customized climate control.
Convenient Installation and Maintenance
Max
capcity
128HP
6.2 1100m Super long piping design
The industry-leading piping length, with a total length of
1100m, makes floor design more flexible.
The max distance between the IDU and the ODU
(ODU is above) is 100m.
The max distance between the IDU and the ODU
(ODU is below) is 110m.
The maximum actual single pipe length is 220m.
The maximum equivalent single tube length is 240m.
The equivalent length from first indoor distributor to
last indoor uni120m.
The maximum distance between indoor units is 40m.
110m
100m
120m 40m
The outdoor unit
on top, the maximum
level difference is The intdoor unit on
top, the maximum
level difference is
Maximum
drop of IDU
Furthest IDU
Nearest IDU IDU
Max
45
6.4130Pa external static pressure
Engineered with advanced fan blades and a high-performance inverter motor, the system delivers a
superior external static pressure of 130Pa*. This ensures reliable and efficient heat dissipation.
6.3 Single system can connect 80 IDUs
TMV6+ adopts the international advanced CAN bus communication technology, and one system can connect up to
80 indoor units, ensure stable and reliable in operation, realizes a large-capacity configuration of a single system,
and is more flexible in engineering applications.
*Customizable to 130Pa.
Better heat dissipation, better refrigeration effect
MAX 130Pa
VRF static pressure contrast diagram
TMV6+
Ordinary VRF
TmvS
46 6.7 One-touch commissioning function
You can choose to debug on the outdoor unit side or remotely through the monitoring software to realize the
cooling and heating trial operation, no need opening the indoor units one by one, which is convenient for on-site
debugging and improves the quality of construction at the project site.
6.8 Non-polarity communication connection
CAN bus communication mode is applied between indoor and outdoor unit, no need to distinguish between
positive and negative poles, and the installation is simpler and more efficient.
Convenient Installation and Maintenance
6.6 Compact design and convenient transport
The outdoor unit module has only 4 basic structures with the same height, which simplifies the design process and
improves the flexibility of the system.
Parallel 8 to 12HP Parallel 14 to 22HP Parallel 24 to 26HP Parallel 28 to 32HP
925mm 845mm 1340mm 845mm 1760mm 845mm 1900mm 845mm 1780mm 1780mm 1780mm 1780mm
47
Emergency power-off function for IDU maintenance
Commissioning software
Auto-addressing function
6.10
6.11
6.12
If an indoor unit needs to be powered off for
maintenance due to failure, in order not to
affect the operation of the entire system, the
indoor unit can be powered off separately for
maintenance, and other indoor units in the
system can operate normally.
The commissioning software is specially developed for TCL air-conditioning
system, which can carry out real-time status monitoring and loading control
of the air-conditioning system.
It can monitor the real-time operation parameters of 4 outdoor units and 80
indoor units in parallel system; And the operating parameters can be showed
in Curve; It contains the function of saving the original data of operation,
which is convenient for the R & D Engineers to remotely analyze the cause
of failure; It also contains the forced load control function of the equipment,
which is convenient for loading maintenance verification on the project site.
The system can realize the automatic allocation of indoor unit address. There
is no need to dial code during commissioning, which avoids the trouble of
manual setting one by one. It is more intelligent and convenient.
4 ODUs
MAX
80 IDUs
2 IDU separately power off for maintenance
6.9 360°pipe connection design
These units allow the freedom to connect the piping in multiple directions,
such as front side, left side , right side and back side , making installation
easier.
48 8 to 12 HP
24 to 26 HP
14 to 22 HP
28 to 32 HP
Product parameters
ODU lineup 1. Specifications are based on the following conditions:
2. Cooling: Indoor temperature 27°C DB/19°C WB,and outdoor temperature 35°C DB/24°C WB.
3. Heating: Indoor temperature 20°C DB/15°C WB,and outdoor temperature 7°C DB/6°C WB.
4. Equivalent piping length:5m; Level difference:0m; Voltage:230V.
5. Sound Level: Indoor unit sound pressure level,measured at a point 1.5m downward from the unit center.
6. Outdoor unit sound pressure level,measured at a point 1.0m in front of the unit.
7. Optional simple wired controller; Universal remote controller; auto-restart(optional); Timer:only one circle.
8. Due to ongoing product development, specifications are subject to change without notice.
Notes:
49
ODU parameters(8-32HP)
1. Specifications are based on the following conditions:
2. Cooling: Indoor temperature 27°C DB/19°C WB,and outdoor temperature 35°C DB/24°C WB.
3. Heating: Indoor temperature 20°C DB/15°C WB,and outdoor temperature 7°C DB/6°C WB.
4. Equivalent piping length:5m; Level difference:0m; Voltage:230V.
5. Sound Level: Indoor unit sound pressure level,measured at a point 1.5m downward from the unit center.
6. Outdoor unit sound pressure level,measured at a point 1.0m in front of the unit.
7. Optional simple wired controller; Universal remote controller; auto-restart(optional); Timer:only one circle.
8. Due to ongoing product development, specifications are subject to change without notice.
Notes:
Model:TMV-VED+(**)W/AS-D(E)
252 280 335 400 450 504 560 615 680 730 785 850 900
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP 32HP
Power Supply V~,Hz,Ph 380-415V 3N ~ 50Hz
Cooling
Capacity W 25200 28000 33500 40000 45000 50400 56000 61500 68000 73000 78500 85000 90000
Input W 7850 8890 12500 14550 18000 19530 24240 30000 31480 39460 34450 39950 45000
Current A 12.52 14.18 19.94 23.21 28.71 31.15 38.66 47.85 50.21 61.00 54.95 63.72 71.77
SEER W/W 7.35 7.26 7.05 6.75 6.25 6.61 6.41 6.2 6.5 5.5 6.26 6.16 5.97
ηs,c % 291.00 287.40 279.00 267.00 247.00 261.40 253.40 245.00 257.00 217.00 247.40 243.40 235.80
Heating
Capacity W 25200 28000 33500 40000 45000 50400 56000 61500 68000 73000 78500 85000 90000
Input W 6000 7180 9100 11420 15000 13800 16100 18700 18630 24740 23760 26130 28125
Current A 9.57 11.45 14.51 18.21 23.92 22.00 25.68 29.82 29.71 39.46 37.91 41.67 44.86
SCOP W/W 4.5 4.45 4.4 4.42 4.39 4.40 4.35 4.30 4.50 4.16 4.28 4.2 4.2
ηs,h % 177.00 175.00 173.00 173.80 172.60 173.00 171.00 169.00 177.00 163.40 168.20 165.00 165.00
Max. Input Consumption W 11300 12430 13730 18400 21390 23700 26070 31490 33270 41250 39440 41250 48700
Max. Current A 20.03 22.03 24.33 32.6 37.9 42.00 46.2 55.8 58.95 66.9 69.9 73.1 79.06
Circuit breaker A 25 25 32 40 40 50 63 63 63 80 80 80 80
Outdoor Fan Motor
(Output Power x Fan quantity) W 560×1 560×1 560×1 920×1 920×1 560×2 560×2 560×2 920×2 920×2 920×2 920×2 920×2
Air Flow Volume m3
/h 11000 11000 11500 13500 14000 19000 19000 20000 26000 26000 29000 29000 29000
Sound Pressure Level dB(A) 58 59 62 66 68 68 68 68 68 68 68 68 68
Sound Power Level dB(A) 83 84 86 90 93 93 93 93 93 93 93 93 93
Dimension
(W×D×H)
Net mm 925x845x1780 1340x845x1780 1760x845x1780 1900x845x1780
Packing mm 1000×925×1940 1415×925×1940 1835*925*1940 1975x925x1940
Weight
Net kg 215 215 215 270 270 315 315 320 380 380 455 455 455
Gross kg 225 225 225 290 290 335 335 340 405 405 480 480 480
Refrigerant
type/
Quantity
Type / R410A
Charged Volume kg 9 9 9 11 11 14 14 16 18 18 28 28 28
Refrigerant
Piping
Liquid Side Inches 3/8'' 3/8'' 1/2'' 1/2'' 1/2'' 5/8'' 5/8'' 5/8'' 3/4'' 3/4'' 3/4'' 3/4'' 3/4''
Gas Side Inches 3/4'' 7/8'' 1'' 1'' 9/8'' 9/8'' 9/8'' 9/8'' 5/4'' 5/4'' 11/8'' 3/2'' 3/2''
Max. Length
(from the first branch pipe) m 120
Max. Height
(outdoor on top/below) m 100/110
Ambient Temp (Cooling/Heating) °C -15~56/-30~28
50 Powerful High Efficiency Comfortable Stable
MiNi VRF
Full DC Inverter MINI VRF Unit
50