PEOPLE
High Voltage Equipments
COMPLETE SETS OF EQUIPMENT
PEOPLE ELECTRIC PRODUCT SALES MANUAL
COMPANY PROFILE
People Ele. Appliance Group was wholly owned company of People Holding Group, one of Chinese Top 500 Enterprise, and founded in the year 1996.
Industrial electrical products as the core business of People Ele. Appliance Group, People Electric owns Zhejiang, Shanghai, Nanchang, Fuzhou, Nantong and Zaozhuang six manufacturing bases, 35 wholly owned subsidiaries, 150 holding member enterprises, over 1500 cooperated processing enterprises and over 5000 sales companies.
The products are popularly sold to over 125 countries and regions, which are widely used in Pudong Airport, Beiing-Shanghai high-speed railway, Three Gorges Hydropower, Beijing Subway, Olympic venues, South North Water Transfer, Qinghai-Tibet Railway, Chang'e Lunar Exploration Project and Vietnam Taian hydropower project etc. major projects at home and abroad, which ranked among the World's Top 500 Machinery Enterprises.
Assess by the World's Brand Laboratory, the brand value reaches to RMB110.927 bilion Yuan.
Perfect industry chain and personalize solutions, Satisfying the different requirements of global customers
Power and energy
• Power
• Petroleum and petrochemical
• Transportation
• Mining / building materials
• Water / water treatment
• Car
Date center
·IT
• High technology
• Internet
Commercial
network
• Bank insurance
• Public construction
• Community facility
Building
• Official building
• Industrial building
• Basic facility
Residence
• Residential construction
• Public construction
• Community facility
Contents
SWITCHGEAR
8PT Low voltage switchgear 01-02
Blokset D Low voltage switchgear (Authorized by Schneider) 03-04
MNS 2.0 Low voltage switchgear (authorized by ABB) 05-06
MD190 (HONOR) Low-voltage distribution system, combined
low-voltage switchgear (ABB authorized) 07-09
GCS Low-voltage drawer switchgear 10-14
GCK, GCL Low-voltage drawer switchgear 15-20
MNS Low voltage switchgear 21-23
GGD AC Low voltage distribution switchgear 24-26
KYN28-12 Indoor metal armored center-mounted removable switchgear 27-30
KYN28-24 Armored removable metal closed switchgear 31-33
KYN18A-12 Indoor AC armored removable metal closed switchgear 34-37
XGN15-12(L·R) Box-type fixed indoor AC metal closed switchgear 38-39
HXGN15-12 (F·R) Boxed type fixed AC metal closed ring main switchgear 40-42
ZBW Series Combined substation 43-45
SWITCHGEAR CASING
KYN61C-40.5 High voltage switchgear case 46-48
KYN28A-24 High voltage switchgear case 49-50
KYN28A-12 High voltage switchgear case 51-54
HXGN15-12 High voltage switchgear case 55-56
GGD Low voltage switchgear case 57
MNS, GCK, GCS Low voltage case 58-60
XL-21 Power box case 61
JXF Distribution box case 62
COMPREHENSIVE PROTECTION DEVICE
RPS-2000 Comprehensive automation system of microcomputer substation 63-66
HIGH VOLTAGE VACUUM CIRCUIT BREAKER
ZN73-12(VS1) Indoor type high voltage AC vacuum circuit breaker 65-70
ZW32-12 Outdoor type high voltage AC yacuum circuit breaker 71-73
ZN73S-24 Indoor type high voltage AC vacuum circuit breaker 74-75
ZW32-40.5 Outdoor type high voltage AC vacuum circuit breaker 76-79
ZW7-40.5 Outdoor type high voltage AC vacuum circuit breaker 80-82
HIGH VOLTAGE DISCONNECTOR
GN19-12 Indoor type High voltage AC disconnector 83-84
GN24-12D Indoor type High voltage AC disconnector 85-86
GW4-40.5 Outdoor type High voltage AC disconnector 87-88
8PT
Low voltage switchgear
Modular design
Each SIVACON is completely made of standardized and typical modules. All modules meet the evaluation indicators and design indicators of People's Electrical Appliances Group in terms of quality. The module has a variety of combination possibilities, so it can meet various requirements. All highquality People's Electrical Appliance Group switching appliances can ensure long service life and high operational reliability.
Characteristics of SIVACON
Type Tested Low Voltage Switchgear (TTA)
Horizontal busbars are uniformly arranged above the switchgear cabinet
3-pole and 4-pole horizontal bus systems with rated current up to 7400A
Rated peak withstand current Ipk up to 375kA
The depth and size of the device compartment are large, which is suitable for various installations
Device compartments can be divided into different units according to the analog structure
Switchgear can be installed on one side or back to back
The incoming line can be used as an up-incoming line or a down-incoming line
Optimally adapts to the conditions of the switchgear installation site
Reliable Wall Installation or Free Floor Installation
The cable can be selected from the upper or lower inlet line
Easy connection of horizontal busbar
The cable can be connected in front of the cabinet or in the back of the cabinet
Device compartment
Horizontal wiring compartment (optional)
Horizontal busbar compartment
Cable inlet compartment for up/back inlet of cable
8PT
Skeleton and case: Precise size, firm structure
The frame is the load-bearing structure of the switchgear cabinet, which is composed of solid steel plate materials connected with each other.
The SIVACON has an accurate and stable skeleton. It comes in two structural types, either screwconnected or welded
The skeleton has holes with a mold of 25mm, which can be extended for various purposes.
The door body is flexible and can meet all kinds of requirements,
The opening angle of the door can be up to 180 °.
The rotary shank barrel lock can reliably prevent the door from bouncing open due to negligence or accident.
The top of the cabinet is equipped with a pressure relief device.
Surface treatment
Powder spraying, spraying or zinc can be used.
Material
The skeleton and case are made of steel plate, the thickness of which is:
Skeleton: 2.5 mm
Outside case: 2.0 mm
The protection grade complies with the provisions of IEC 60529 IP30, IP31, IP40, IP41, IP42 Natural ventilation cabinets Ip40, IP54 non-ventilated cabinets
Outside dimensions of switchgear cabinets (without enclosure)
| Depth of the cabinet | Depth of the cabinet | Depth of the cabinet |
| 2200 | 400,600,800,1000,1200 | 600,800,1000,1200 |
| 2600 | 400,600,800,1000,1200 | 800,1000,1200 |
Blokset D
Low voltage switchgear (Authorized by Schneider)
Solutions to global challenges
Blokset D is a new type of low voltage switchgear designed by Schneider Company introduced by People Electric Group Shanghai Co., Ltd. As a unified low voltage distribution solution for customer needs, it has extremely high safety, reliability and flexibility.
By cooperating with local excellent and high-level low-voltage switchgear manufacturers, Schneider has made them qualified "technical partners" of BloksetD, so that this multi-purpose BloksetD low-voltage switchgear can come to you completely. side.
A full range of designs to meet your different application requirements
Modular multifunctional system
D Type: Distribution cabinets below 6300A
DC Type: power factor compensation cabinet
Mf Type: fixed motor control center up to 6300A
U Type: showcases below 6300A
Mx Type: chest of drawers below 6300A
Mw Type: Bending cabinets below 6300A
Ms Type: frequency converter and soft starter cabinet
Blokset D
Low voltage switchgear (Authorized by Schneider)
Case
Blokset can provide different case protection grades according to requirements, IP20-IP54. The outer case of the cabinet is sprayed with epoxy resin powder, the standard color is light gray RAL9002, and the ventilation baffle is dark gray RAL7016. All non-live parts of the metal structure are reliably grounded, and have obvious grounding marks to ensure the safety of operators.
Frame
The frame of Blokset is assembled by standard prefabricated components with preset spacing modulus holes, and the standard modulus of Blokset is M = 50mm. The switchgear with various widths and depths can be formed by combining the basic frame and the extended frame. The main structure adopts the assembly method, and it is guaranteed that there will be no deformation under the normal transportation, storage and installation conditions.
Depth and width
Blokset series switchgear can be composed of a variety of depth and width switchgear through the combination of basic frame and extended frame.
The basic frame can have 3 depths
●400mm
●600mm
●1000mm
The 400mm deep frame is only used when the horizontal bus current is less than 1600A. The 600mm deep frame is the most commonly used basic frame. A 400mm depth extension can be added to the 600mm deep basic frame to achieve a depth of 1000mm, which is often used in the case of rear outlet lines.
The basic frame can come in a variety of widths
500mm (Mw type)
600mm (Mx/U)
●700mm
800mm (U-shaped)
●900mm (Mw/U)
1000mm (U-shaped)
1200mm (for Masterpact MT40b/50/63)
Expansion cabinets (200 to 400mm) can be added on both sides of the cabinets as needed
MNS 2.0
Low voltage switchgear (Authorized by ABB)
Description
MNS2.0-Low Voltage Switchgear is a new type of low voltage switchgear designed by ABB Company introduced by People Electric Appliance Group Shanghai Co., Ltd. As a unified low voltage distribution solution for customer needs, it has extremely high safety, reliability and flexibility.
By cooperating with local excellent and high-level low-voltage switchgear manufacturers, ABB has made them qualified ABB's "technical partners", allowing this multi-purpose ABB low-voltage switchgear to come to you completely side.
System characteristics
MNS 2.0 assembled low-voltage switchgear system has been used in the world market for many years, and its value has been confirmed. The whole system fully considers the future development space, and can avoid the risk of being eliminated due to technological development.
The cabinet structure adopted by the MNS 2.0 system has high flexibility, and once the structure is assembled, it does not need to be repaired. Different standard components can be installed in the cabinet to meet various usage requirements. Since the entire system including the electrical structure adopts a combined design, this optimized structural design meets the requirements of various components, and is suitable for different working environments, reaching the corresponding protection level.
Compared with traditional products, MNS 2.0 system has more advantages:
Compact structure, saving the volume of the cabinet
Cabinets are arranged back to back
Distribution circuit layout is economical
All standard components are selected, which is convenient for engineering designers to design
Full series standardization
The cabinet body can be designed with corresponding protection grades according to different requirements of work and environment
Different types of functional components can be freely installed in one cabinet, such as: fixed components and withdrawal components
Convenient equipment update and improvement
High continuity and reliability of equipment operation
The personal safety of operators is guaranteed
Structure design
Frame
The basic part of the frame of MNS 2.0 system is a C-shaped frame (DIN43660) with 25mm interval modulus holes. The standard modulus of MNS system is E = 25mm. Due to the use of the standard modulus hole system, the frame structure can be assembled into various types of cabinets without special tools, such as front-operated and back-to-back switchgear cabinets with single or multiple sets.
Case
MNS 2.0 system can be designed with different protection levels according to different usage requirements. For rear operation and joint screen cabinets, the outer case with front protection level of IP30 can be selected, and the fully enclosed external charging protection level is IP40-IP54 (the withdrawal switchgear is fully enclosed). The hinge frame can be used for installation
MNS 2.0
Low voltage switchgear (Authorized by ABB)
For electronic devices and instrument panels, and can also be used as device frames. A cover plate with/without observation holes can be added to the installation position of the chain frame. A bottom plate can be provided at the bottom of the cabinet, and an electrical system slot can be installed after adding a flange plate. Door panels and shells can be equipped with single/multiple vents, and the top plate can be fully ventilated (suitable for IP40 and IP41).
Cabinet structure
The cabinet structure of MNS 2.0 system can be divided into: device chamber, bus chamber and cable chamber. Dimensions (height x width x depth) are 2200mmx400/600/800/1000/1200mmx600/800/1000 mm. If the air circuit breaker is less than 2000A, the width of the switch cabinet can be 400mm. The maximum length of the transport unit is 3000mm. A switch (fixed disconnector/fixed or withdrawn molded case circuit breaker/air circuit breaker) is installed in the inlet/outlet cabinet and the bus cabinet. In MNS2.0 system, the components of the same functional group can be assembled to form a simple mechanical and electrical functional component, including power component and control component. According to different requirements, the structure of the cabinet frame can be divided into:
-In the device chamber are functional unit assemblies
-In the bus chamber are the bus and the distribution bus
-In the electrical system chamber is the inlet and outlet electrical system (upper and lower inlet and outlet lines are acceptable)
Connecting wires and components between functional unit components, such as cable clamps, electrical system connectors, parallel wires, wiring grooves, etc
Separation can be made between the functional units and the cabinets in the cabinet, and the internal separation can reduce the arc destructiveness to the minimum.
MD190(HONOR)
Low-voltage distribution system, combined lowvoltage switchgear (ABB authorized)
Product characteristics
ABB's full range of low voltage electrical components, including Megamax and Emax air circuit breakers, somax and Tmax molded case circuit breakers and A series contactors, are used to form a complete and most reliable low voltage system.
High-strength profiles make the structure of the switchgear stronger.
Complete scheme, with fixed partition type and drawer type for arbitrary selection and assembly, can keep the appearance consistent
Adopting modular frame cabinet depth width, height, strong adaptability and flexible design scheme.
Compact arrangement, saving space and cost.
Free combination of unit components, strong versatility, flexible changes, and meeting project needs.
With different shell protection levels and internal isolation forms, users can choose according to requirements
Convenient and fast assembly, without special and complicated procedures.
Frame and case
The MD190 frame system takes 190 mm as a standard modulus (1U), and includes an outer frame and an inner frame (used as a strong cabinet structure for separating the cell). The connection of the outer frame uses tee links to ensure the symmetry of the frame installation.
The case protection level of MD190 is IP31 standard, the front adopts door panels that can be opened from the left or right, with waterproof sealant strips and ground screws. The rear adopts door covers, with waterproof sealant strips and heat dissipation holes. The protection level of the outer shell can be increased to IP54 as needed (double front doors, front outer doors with high-quality tempered glass).
MD190(HONOR)
Low-voltage distribution system, combined lowvoltage switchgear (ABB authorized)
Structure design
Cabinet structure
The cabinet frame structure of Md190 adopts modular frame structural parts, so that the height, depth and width of the cabinet body can be changed and combined into a variety of different external dimensions according to modulus
The inside of the cabinet is divided into three separate chambers:
a) Device chambers for unit assemblies
b) Busbar chambers of main busbars and distribution busbars
c) Inlet and outlet cable chamber (can go up and down inlet and outlet lines)
Main bus and distribution bus:
The main bus is assembled in the bus chamber and can be installed horizontally at different positions from top to bottom.
The capacity of the main bus is 800-6300A.
The distribution bus is installed vertically, and the capacity of the distribution bus is from 800-3200A.
Main busbar(2500A)
Cabinet frame structure of fixed separated type switchgear
Modular cabinet height, depth, width.
Cabinet height: Standard is 2090 (11 modules) + 95mm (base height)
Highest is 2280 (12 modules) + 95mm (base height)
Cabinet depth: rear wiring scheme, standard cabinet depth 1010mm/1200mm
Front wiring scheme, standard cabinet depth is 440/630/820mm (according to current carrying capacity)
MD190(HONOR)
Low-voltage distribution system, combined lowvoltage switchgear (ABB authorized)
Cabinet width: from 380mm (2 modules) to 1140mm (6 modules) Example:
(1) Rear wiring MCC solution: 380mm (6 pcs of MCCB can be installed), 570mm, 760mm (12 pcs of MCCB can be installed) three Specifications.
(ii) Rear wiring incoming solution: 760mm, 950mm, 1140mm three specifications Case protection: Standard IP31, up to IP54 according to project requirements.
The size of the integral cabinet frame remains unchanged, only double doors (exterior doors with strengthened glass) and the structure of small chambers inside the cabinet are used, and corresponding adjustments must be made.
Internal separation form: Form 3 (standard form) and Form 4, Form 2 (capacitive compensation cabinet and power control panel)
Standard solution:
1) Power distribution: incoming line, communication, feed, two power supply ATS system and three power supply ATS system
2) Motor control: direct start, reversible start, star-triangle start and soft start
3) Reactive power compensation: UA series contactor for switching capacitor of ABB company and CLMD
series dry type with small size and good heat dissipation are used
Capacitor Unit Component:
Specifications and solutions
1) There are six specifications for unit assemblies: (width X height)
380mmX (190/285/380) mm Three specifications
760mmX (190/285/380) mm Three specifications
The maximum number of unit circuits can be installed in the cabinet is 18, and the maximum current capacity is 160A.
2) Component solutions
Moulded Case Circuit Breaker for Distribution (MCCB)
Motor Control with Molded Case Circuit Breaker
Structural features:
1) There is a reliable interlock between the unit drawer circuit breaker and the door (that is, only when the circuit breaker is broken, the chamber door can be opened)
2) The two groups of the plug-ins for the drawer's main circuit incoming and outgoing, enter into the precalculated position step by step, which reduces the operating torque of tapped insertion and withdrawal.
3) The movement of the plug-ins adopts the propulsion and withdrawal mode of the combination of guide rail and screw rod, the operation force is small, the stability is good, and there is obvious connection, test and separation position indication
4) Even after the unit components are withdrawn, the plug-in position of the components in the switchgear will still maintain the IP20 protection level.
IPD (Intelligent Power Device) series products are automation products for special sub-low voltage system intelligence launched by ABB.
The product series includes communication processor and HMI human-machine interface, M101-M/M102-M intelligent motor control unit, PMC916 power monitoring and control device, EM-plus intelligent power meter. RTU monitoring and distributed control device and special current transformer, etc.
IPD product series are complete, which can realize the functions from low-end intelligent data acquisition to high-end intelligent field monitoring and management
The low-voltage switchgear equipped with IPD can directly establish communication connection with the superior system through the Ethernet interface (TCP/IP protocol), so IPD is an important tool to realize the transformation from traditional low-voltage switchgear to intelligent low-voltage switchgear. IPD products all adopt standard communication interfaces and open communication protocols, and can communicate with any computer management system, such as BAS system, DCS system, distribution network automation system, power dispatching system, etc.
GCS Low-voltage drawer switchgear
Description
GCS low-voltage drawer switchgear (hereinafter referred to as the device) is designed and developed by the two joint design groups according to the requirements of the industry competent department, the majority of power users and design units. It is a low-voltage extraction switchgear that conforms to the national conditions, has high technical performance indicators, can meet the development needs of the power market and can compete with the existing imported products. This device has been widely used by power users.
The device is suitable for power distribution systems in power plants, petroleum, chemical industry, metallurgy, textile, high-rise buildings and other industries. It is a low-voltage complete set of power distribution equipment used for power distribution, motor centralized control, and reactive power compensation in power generation and supply systems with three-phase AC frequency of 50 (60) Hz, rated working voltage of 380V (400), (660), rated current of 4000A and below in places with high degree of automation, such as large power plants and petrochemical systems.
The basic organization of the device is shown in Figure 1.
Devices are designed to meet the following criteria
IEC439-1 "Low Voltage Switches and Control Equipment"
Gb7251 Low Voltage Switchgear Set
JB/T9661 "Low Voltage Extraction Switchgear"
Model No.
Main technical parameter
1. Basic technical parameter to see table 1
| Rated voltage of main circuit (V) | AC 380 (400), (660) | |
| Rated voltage of auxiliary circuit(V) | AC 220, 380(400), DC110, 220 | |
| Rated frequency (Hz) | 50(60) | |
| Rated insulation voltage (V) | 660(1000) | |
| Rated current (A) | Horizontal wiring | ≤4000 |
| Vertical busbar (MCC) | 1000 | |
GCS
Low-voltage drawer switchgear
| Table 2 | ||
| Rated short-time withstand current of busbar (kA/1s) | 50,80 | |
| Rated peak value withstand current of busbar (kA/0.1s) | 105,176 | |
| Power frequencytesting voltage (V/1min) | Main circuit | 2500 |
| Auxiliary circuit | 1760 | |
| Busbar | Three phase four wire | A. B. C. PEN |
| Three phase five wire | A. B. C. PE.N | |
| Protection grade | IP3L0. IP4L0 | |
2. Main circuit scheme
The main circuit scheme of the device has 32 groups and 118 specifications, excluding the schemes and specifications derived from the change of the control and protection of the auxiliary circuit. It includes the needs of power generation, power supply and other power users. The rated working current is 4000A, which is suitable for the selection of distribution transformers below 2500kVA. In addition, a capacitor compensation cabinet is designed to meet the needs of power supply and power factor improvement; Considering the need of comprehensive investment, the reactor cabinet is designed.
Remarks:
01. DW914 is the main circuit breaker, and other circuit breakers with more advanced performance or RDSW6 (RDW1), F, M series can also be selected.
02.01, 02, 04 solutions If the PE N cable needs to enter the power cabinet, the width of the cabinet should be sized in brackets.
03. SDL and SDH are special power transformers for GCS cabinets.
3. Auxiliary circuit scheme
There are 120 auxiliary circuit schemes in GCS Auxiliary Circuit Atlas, which are divided into two volumes. The first volume "AC Operation Part" is divided into 63 schemes, and the second volume "DC Operation Part" is divided into 57 schemes.
The auxiliary circuit scheme of the DC operation part is mainly used in the low voltage power plant (station) system of the power plant and substation. It is suitable for the low voltage power plant system of the unit with the capacity of 200MW and below and 300MW and above, and the general control mode of the working (backup) power supply incoming line, power supply feeder line and motor feeder line
The auxiliary scheme of AC operation part is mainly used for low voltage system of substation in factories, mines, enterprises and high-rise buildings. There are 6 combined schemes suitable for double power supply operation control, and there are control circuits such as operation electric interlock backup self-switching and self-recovery, which can be directly used in engineering design.
The DC control power supply is DC 220V or 110V, and the AC control power supply is AC 380V or 220V. The 220V control power supply is drawn from the public control power supply supplied by the special control transformer in the cabinet. The public control power supply adopts the ungrounded mode to control the transformer, and the 24V power supply is reserved for the use of weak electric signal lamps. For the installation location of the watt-hour meter, the introduction method of voltage and other installation and use requirements, please refer to the "Compilation Instructions" of the auxiliary circuit diagram
4. Bus
In order to improve the dynamic thermal stability of the bus bar and improve the temperature rise of the contact surface, TMY-T2 series hard copper bars are used in all devices. The connecting parts of the copper bars must be tin-enameled. Full-length tin-enameled copper bars are recommended, and full-length silver-plated copper busbars can also be used.
GCS
Low-voltage drawer switchgear
a. Horizontal busbar level
The bus bar is located in the bus bar compartment at the back of the cabinet, and the upper and lower double layers are arranged for 3150A and above, and the single layer is arranged for 2500A and below. Each phase is composed of 4 or 2 busbars, which greatly improves the short-circuit strength of the bus bar.
Table 3
| Rated current A | Busbar specification |
| 630 1250 | 2(50×5) |
| 1600 | 2(60×6) |
| 2000 | 2(60×10) |
| 2500 | 2(80×10) |
| 3150 | 2×2(60×6) |
| 4000 | 2×2(60×10) |
b. Vertical busbar
The vertical busbar used for the drawer adopts "L"-shaped hard enameled-tin busbar. L-shaped busbar specification (mm): (height × thickness) + (bottom × thickness) (50 × 5) + (30 × 5) Rated current 100A C. Neutral grounding bus
Use hard copper bars. Through horizontal neutral ground wire (PEN) or ground +neutral wire (PE + N) specifications are shown in Table 4.
| Phase conductor cross sections each mm | Select PE (N) wire cross section mm |
| 500-720 | 40×5 |
| 1200 | 60×6 |
| >1200 | 60×10 |
5. Selection of electrical components
The equipment mainly selects electrical components with advanced technical performance index and imported technology, which can be mass-produced in China.
a. Main switch
For 630A and above power supply inlet and feeder switches, the main selection is DW914 series, and RDSW6 (RDW1), DW40, DW48 series, AE series, 3WE or RDW17 series can also be used. If necessary, imported M series or F series can also be used.
b. For 630A and below feeders and motor control switches, mainly choosing RDM949 series and RDM1 series MCCB, and can also use the NZM Series and TM30 Series MCCB.
c. AC contactor, mainly choose CJX8 series, CJX2 (RDC6) series, CJX1 series contactors and their matching thermal relays and interlocking mechanisms.
GCS
Low-voltage drawer switchgear
d. All current transformers adopt SDH series, SDL series and SDL1 series supervised by Senyuan Electric Co., Ltd.
e. Fuse selects HH15 series knife-fuse disconnector and NT00 series with high breaking capacity. f. In order to improve the dynamic stability of the main circuit, the special CMJ bus clamp and insulation support for GCS series are designed. It is thermoplastic formed with high strength flame retardant composite material, which has high insulation strength, good self-extinguishing performance and unique structure. It is only necessary to adjust the building block block to be suitable for different specifications of the bus.
g. In order to reduce the temperature rise of the spacer, connector and electric head of the functional unit, the special adapter for GCS cabinet is designed. Compared with the same kind of products, the heat capacity of the adapter increases and the temperature rise decreases.
h. If the design department selects new electrical components with better performance and more advanced technology according to the needs of users, because the GCS series cabinets have good versatility, it will not cause difficulties in manufacturing and installation due to updating electrical components.
Structure characteristics
1. The main frame of the device adopts 8MF section steel, and the frame adopts two structural forms: assembly and partial welding. There are installation modulus holes E = 20mm on the main frame
2. Each function room of the device is strictly separated, and the compartments are mainly divided into function unit room, bus room and electrical system room. The functions of each unit are relatively independent.
3. The size series of the device cabinet is as shown in the table
| Height | 2200 | ||||||||
| Width | 400 | 600 | 800 | 1000 | |||||
| Depth | 800 1000 | 800 | 1000 | 600 | 800 | 1000 | 600 | 800 | 1000 |
4. Functional units
A. The module of the drawer layer height is 160mm, which is divided into five size series: unit, unit 1, unit 1, unit 2, and unit 3.
Unit circuit rated current 400A and below.
b. The drawer changes only in height and size, and its width and depth are unchanged. Drawers with the same functional unit have good interchangeability.
c. Each MCC cabinet can install up to 11 one-unit drawers or 22-unit drawers. More than one unit drawer adopts multi-functional rear panel
d. The inlet and outlet lines of the drawer adopt connectors with the same specification and chip structure with different numbers of chips according to the current.
e. The adapter between the unit drawer and the cable room adopts the back plate structure ZJ-2 adapter. f. The adapter between the unit drawer and the cable room adopts the same size rod or tube structure ZJ-1 adapter according to the current classification.
g. The drawer panel has obvious marks for the positions of splitting, closing, testing, and withdrawing.
h. The drawer unit is provided with a mechanical interlocking device.
5. Feeder cabinets and motor control cabinets are equipped with special cable compartments, and the connection between functional unit cabinets and cable rooms is realized by adapting parts or copper bars, which not only improves the reliability of cable use, but also greatly facilitates the installation and maintenance of cables by users.
The cable compartment has two widths (240mm and 440mm) to choose from, depending on the number of cables, the cross section and the user's requirements for easy installation and maintenance.
GCS
Low-voltage drawer switchgear
6. The number of auxiliary contacts of the functional unit of the device is 32 pairs for one unit or more, and 20 pairs for the unit, which can meet the needs of the interface between automation users and computers.
7. Considering the common safety of dry-type transformer and the economy of oil-immersed transformer, the device can be conveniently formed into a group with dry-type transformer, and can also be conveniently connected with the low-voltage bus of oil-immersed transformer.
8. The drawer is the main body, it has the drawer type and fixed type at the same time, which can be mixture combined, and can be selected arbitrarily.
9. The device is designed according to three-phase five-wire system and three-phase four-wire system.
The design department and users can easily choose PE + N or PEN mode.
10. The protection level of the cabinet is IP3LO and IP4LO, which can also be selected according to the needs of the user.
General purpose cabinet frame
GCK、GCL
Low-voltage drawer switchgear
Description
GCK and GCL series low-voltage drawer type switchgear are designed by our company according to the needs of the vast number of users. They have the characteristics of advanced structure, beautiful appearance, high electrical performance, high protection grade, safety and reliability, and convenient maintenance. They are ideal distribution devices for low-voltage power supply systems in industries such as metallurgy, petroleum, chemical industry, electric power, machinery, and textiles.
It is listed as a recommended product for the transformation of the two grids and the ninth batch of energy-saving products by the state.
Model No. and its implication
Main technical parameter
Rated insulation voltage: 660v
Rated working voltage: 380V 660V
● Rated voltage of auxiliary circuit: AC220v, 380v, DC110v, 220v
● Using frequency: 50 \~ (60) Hz
●Rated current: horizontal bus ≤ 3150A, vertical bus 630A, 800A
●Rated short-term withstand current: 105kA/1S, neutral bus 30kA/1S
GCK、GCL
Low-voltage drawer switchgear
●Rated peak current: 105kA/0.1 S, 50kA/0.1 S
Functional unit (drawer) breaking capacity: 50kA (effective value)
Case protection grade: IP30, IP40
Bus setting: three-phase four-wire system, three-phase five-wire system
Meet the standards:
IEC-439 BS5486 VDE0660, GB7251, NEMAIC2-322, JJB/T9661
Operation mode: in-site, remote, automatic
Structure characteristics
The basic cabinets of GCK and GCL are the combined assembly structure, all the structural parts of the cabinets are galvanized, sprayed and fastened with screws to form the basic cabinets. Doors, baffles, partitions, drawers, mounting brackets, busbar and electrical components are added as needed to assemble a complete control center cabinet. The structure of this cabinet has the following characteristics:
1. Cabinet frame
The cabinet frame adopts special-material steel, uses corner plate positioning, and bolts connection without welding structure.
a. Forming size of the spare parts, opening size and equipment interval uses modular. (Modulus \mathsf { E } = 20mm, the same below).
b. The internal structural parts are galvanized.
c. The exterior is phosphate: then sprayed with electrostatic epoxy powder.
d. The cabinets are divided into three separate sections: bus room, functional unit and cable room, which can prevent accident from spreading and convenient for the maintenance with live.
GCK、GCL
Low-voltage drawer switchgear
GCK、GCL
Low-voltage drawer switchgear
2. Functional unit (drawer part)
a. Functional units: Feed units, motor units, public power supply units.
b. The height modulus of the drawer layer is 200mm, and it is divided into six size series:-unit, 1 unit, 1- unit, 2 unit, 2-unit, and 3 unit. The rated current of the unit circuit is 630A and below.
c. Each MCC cabinet can be equipped with a maximum of 9 pcs of -unit drawers or 18 pcs of -unit drawers.
d. The door panel of the compartment is mechanically interlocked with the drawer by the operating mechanism of the main switch. When the main switch is in the closing position, the door panel cannot be opened.
e. The operating mechanism of the main switch can be locked in the closing or opening position with a pick lock, which can safely carry out maintenance of electrical equipment.
g. The valve in the compartment opens and closes automatically with the push and pull of the draw, so that it cannot touch the vertical bus bar in the compartment
h. The back of the function unit is provided with an inlet and outlet plug of the main circuit, a secondary plug of the auxiliary circuit and a grounding plug.
I. The grounding plug ensures the continuity of the protection circuit when the drawer is separated from the test connection position
GCK、GCL
Low-voltage drawer switchgear
3. Busbar system
A. RGCK and RGCL bus systems adopt three-phase four-wire system and three-phase five-wire system. Horizontal bus wires are installed on the top of the cabinet, and N and PE wires can be installed on the top of the cabinet or on the bottom of the cabinet.
b. The three-phase horizontal bus bar adopts copper bus bar, which has high mechanical strength and good heat dissipation.
GCK、GCL
Low-voltage drawer switchgear
C. The vertical bus is sealed with carbonate engineering plastic shell.
MNS
Low voltage switchgear
Description
MNS type low-voltage switchgear (hereinafter referred to as low-voltage switchgear) is a product that our company has improved the selection of electrical components and cabinet structure based on the development trend of low-voltage complete switchgear in our country, and re-registered. The electrical performance and mechanical properties of this product fully meet the technical requirements of the original MNS products.
This low-voltage switchgear is suitable for power systems with AC 50 \~ 60Hz and rated working voltage of 660V and below. It is used as equipment control for power generation, transmission, distribution, electric energy conversion and electric energy consumption.
In addition to general land use, this low-voltage switchgear can also be used in offshore oil drilling platforms and nuclear power plants after special treatment.
This low voltage switchgear complies with IEC439, VDE0660 Part 5, GB7251-87 Low voltage complete switchgear and JB/T9661“Low voltage withdrawable complete set of switchgear” industry standard.
Technical parameter
1. Main technical parameter of MNS type low voltage switchgear to see table below
| Rated working voltage (V) | 380、660 | |
| Rated insulation voltage (V) | 660 | |
| Rated working current (A) | Horizontal busbar | 630~5000 |
| Vertical busbar | 800~2000* | |
| Rated short-time withstand current Effective value(1S)/Peak value (kA) | Horizontal busbar | 50 ~ 100/105 ~ 250 |
| Vertical busbar | 60/130~150 | |
MNS
| Protection grade of case | IP30、IP40、IP54** |
| Overall dimension (W×D×H mm) | 600×800、1000×600、(1000)×2200 |
\* Rated operating current of vertical bus: 800A for single-sided or double-sided operation of pull-out MCC, 1000A for movable MCC; The cabinet depth is 1000mm and the MCC for single-side operation is 800 \~ 2000A, \* \* Protection level IP54 is not recommended due to serious capacity reduction.
| Name | Model No. | Main parameter | Name | Model No. | Main parameter |
| Low voltage circuit breaker | DW914(AH) | 600~4000A | Fuse typeDisconnector | DCHR1 | 125~630A |
| Low voltage circuit breaker | RDW17 | 600~3900A | Fuse typeDisconnector | HH15 | 125~800A |
| Low voltage circuit breaker | RDM1RDM2 | 15~630A | AC contactor | CJX2-F(RDC6)CJX2(RDC6)CJX8 | 4.7~630A |
| Low voltage circuit breaker | DZ47-63S503 | 10~63A | Fuse | NGTRT20/NT | 4~630A |
| Low voltage circuit breaker | RDM8LNA | 6~100A | Thermal overloadrelay | JRS2JRS8/NT | 16~370A |
| Fuse type Load switch | SMP | 125~630A | Currenttransformer | LMK1LNLMZ2 | 15 ~5000/5A |
| Fuse type Load switch | OESA | 63A | Capacitor | BSMJCLMB | ~400v(internal △) |
| Low voltage circuit breaker | RDSW6(RDW1) | 600~3200A | Low voltagecircuit breaker | M | 600~6300A |
Structure description
The basic cabinet frame of low-voltage switchgear is a combined assembly structure. All structural parts of the cabinet frame are galvanized, firmly connected with each other through self-tapping locking screws or 8.8 grade hexagonal screws to form a basic cabinet frame. Then, according to the needs of scheme changes, corresponding doors, sealing plates, partitions, installation brackets, busbars, functional units and other parts are added to assemble a complete lowvoltage switchgear. The dimensions of parts and compartments in the switchgear are modularized (modulus unit E = 25mm, the same below).
1. Power distribution center (hereinafter referred to as PC)
The PC cabinet is divided into four compartments, namely the horizontal busbar compartment, at the back of the cabinet; The functional unit compartment is on the upper part of the front of the cabinet or on the left side of the front of the cabinet; Cable compartment, on the lower part of the front of the cabinet or on the right part of the front of the cabinet: control circuit compartment, on the upper part of the front of the cabinet. Separation measures: melamine phenolic sandwich panels or steel plates are used between the horizontal busbar compartment and the functional unit compartment. The control circuit compartment and the functional unit compartment are separated by a flame-retardant polyurethane foam plastic molded seal shell. The functional unit compartment on the left and the electrical system compartment on the right are separated by a steel plate.
Cabinet-frame circuit breakers installed in the cabinet can be manually operated outside the cabinet when the door is closed. Check the opening and closing status of the circuit breaker and determine whether the circuit breaker is in the test position or the working position according to the positional relationship between the operating mechanism and the door.
The main circuit and the auxiliary circuit are designed as a separation structure. The auxiliary circuit units composed of instruments, signal lights and buttons are all installed on a plastic board. There is a cover made of flame-retardant polyurethane foam plastic behind the board. Separate from the main circuit
MNS
2. Withdrawable motor control center and low-current power distribution center (hereinafter referred to as withdrawable MCC)
The withdrawable MCC cabinet is divided into three isolation rooms, namely, the horizontal bus compartment at the back of the cabinet, the functional unit compartment on the left side of the front of the cabinet, and the cable compartment on the right side of the front of the cabinet. The horizontal bus compartment and the functional unit compartment are separated by a functional wall made of flame-retardant foam plastic, and the cable compartment is separated by a steel plate from the horizontal bus compartment and the functional unit compartment.
Withdrawable MCC has two structures: single-sided operation and double-sided operation.
The withdrawable MCC has five standard sizes of drawers, which are 8E/4, 8E/2, 8E, 16E and 24E respectively. The structures of the 8E/4 and 8E/2 drawers are molded flame-retardant plastic parts and aluminum alloy profiles (4 pcs of 8E/4 or 2 pcs of 8E/2 forming an 8E-height interval). The total height of the functional unit compartment is 72E
Five standard sizes of drawers generally have 16 secondary isolation contacts leading out. If necessary, except for the 8E/4 drawer, the other four drawers can be increased to 32. The terminals of each fixed contact can be connected with 3 pcs of wires at the same time. The above terminals are provided by the manufacturer with appropriate accessories and cold rolling pliers with the product.
Through the operation procedure of the mechanical interlocking device, the drawer can only be moved when the main circuit and the auxiliary circuit are all disconnected. The mechanical interlocking device makes the drawer have a moving position, a breaking position and a separating position, and marks them with corresponding symbols.
The operating handle on the mechanical interlocking device and the operating handle of the main circuit breaker can be locked by three padlocks at the same time.
3. Movable motor control center and small current power distribution center (hereinafter referred to as movable MCC)
The cabinet structural characteristics of the movable MCC are the same as (a) and (b) in clause 4.2.
The functional unit is designed as a movable structure. The connection between the functional unit and the vertical busbar uses a primary isolation contact. Even if the circuit connected to it is live, the functional unit can be completely taken out from the equipment and put back. The other end is fixed structure.
The functional units of the movable MCC are divided into 3E, 6E, 8E, 16E, 24E and 40E functional unit compartments, and the total height is also 72E.
4. Busbar system
Horizontal busbar (L1, L2, L3). The horizontal busbar is installed in an independent busbar compartment behind the cabinet. It has two optional installation positions, that is, 1/3 or 2/3 of the cabinet height. The busbar can be installed at the upper or lower part as needed, the upper and lower groups can also be installed at the same time. The two sets of busbars can be used separately or in parallel.
Each phase busbar consists of 2, 4 or 8 busbars connected in parallel, and the busbar cross sections have six kinds of 10x30x2, 10x60x2, 10x80x2, 10x60x4, 10x80x2x2 and 10x60x4x2.
The vertical busbar L-shaped copper busbar with 50x30x5, which is embedded in the functional wall made of flameretardant plastic, and the protection level of the live part reaches Ip20.
Neutral wire (N wire) and protective grounding wire (PE wire). The neutral wire busbar and protective grounding wire busbar are installed in parallel at the lower part of the functional unit compartment and vertically in the cable compartment. If the N wire and PE wire are separated by insulators, the N wire and the PE wire are used separately. If the two are shorted with conductors, the PEN wire will be formed.
5. Protective grounding system
The protection circuit of this switchgear consists of two parts: PE wire (or PEN) installed separately and running through the entire arrangement length and conductive metal structural parts. Except for the external door and sealing plate, the rest of the metal structural parts have been tinned. The connections of the structure have been carefully designed to allow it to pass a certain short-circuit current
6. Auxiliary circuit cable tray
An auxiliary circuit cable tray is installed on the top of the functional unit compartment, and the connecting lines between cabinets and public power lines can be placed in the tray.
7. Isolation measures of auxiliary circuits
In each circuit of the extractable MCC scheme, an isolation transformer can be installed according to the needs of the system. The capacity of the transformer is higher than that of the AC contactor, and the specifications are determined.
GGD
Description
GGD AC low-voltage distribution cabinet is suitable for power users such as power plants, substations, industrial enterprises, etc. It is used as power conversion, distribution and control of power, lighting and distribution equipment in power distribution systems with AC 50Hz, rated working voltage 380V, and rated current to 3150A. This product has the characteristics of breaking capacity and rated short-term withstand current of 50kA. The circuit scheme is flexible, convenient combination, strong practicability and novel structure. This product is one of the representative products of assembled and fixed panel switchgear in China.
This product meets the standards of IEC439 "Low Voltage Complete Switchgear and Control Equipment", GB7251 "Low Voltage Complete Switchgear" and other standards.
Product model No. and its implication
Main parameter
| ModelNo. | Ratedvoltage (V) | Ratedcurrent (A) | Rated short-circuitswitching current (kA) | Rated short-timewithstand current (kA) | Rated peak valuewithstand current (kA) | |
| A | 1000 | 15 | 30 | |||
| RGGD1 | 380 | B | 600(630) | 15 | ||
| C | 400 | |||||
| RGGD2 | 380 | A | 1500(1600) | 30 | 30 | 63 |
| B | 1000 | |||||
| C | 600 | |||||
| A | 3150 | 105 | ||||
| RGGD3 | 380 | B | 2500 | 50 | 50 | |
| C | 2000 | |||||
GGD
AC low voltage distribution cabinet
2. Auxiliary circuit solution
The design of auxiliary circuit is divided into two parts: power supply and consumption scheme and power plant scheme.
3. Main bus
When the rated current is 1500A and below, a single copper busbar is used. When the rated current is greater than 1500A, a double copper busbar is used, and the overlapping surfaces of the busbars are treated with tin enameling process.
4. Electrical component selection
A. GGD cabinets mainly use more advanced electrical components that can be mass-produced in China Such as RDW17, DZ20, DW15, etc.
b. HD13BX and HS13BX rotary-operated knife switch is a special component designed by NLS to meet the needs of the unique structure of GGD cabinet. It changes the operation mode of the mechanism and retains the advantages of old products. It is a utility model electrical component.
c. If the design department selects new electrical components with better performance and more advanced technology according to user needs, GGD cabinets have good installation flexibility and generally will not cause manufacturing and installation difficulties due to updating electrical components.
d. In order to further improve the dynamic stability of the circuit, the bus support of the GGD cabinet adopts special ZMJ combined bus clamps and insulation supports.
The busbar clamps are hot-molded from high-strength, high-flame-retardant PPO composite materials. They have high insulation strength, good self-extinguishing performance, and a unique structure. They can be easily combined into single busbar or double busbar clamps only by adjusting the building blocks. The insulation support is a sleevetype molded structure, which has low cost and high strength, and solves the defect of insufficient creepage distance of old products.
Structure characteristics
1. The cabinet of GGD AC low-voltage distribution cabinet adopts the form of a general cabinet. The frame is partially welded or assembled with 8MF cold-formed steel. The frame parts and special supporting parts are produced and supplied by our company to ensure the accuracy and quality of the cabinet. The parts of the general cabinet are designed according to the modular principle, and have 20 modular mounting holes. The general coefficient is high which can enable the factory to achieve pre-production, which not only shortens the manufacturing cycle, but also improves the work efficiency.
2. The design of the GGD cabinet fully takes into account the heat dissipation problem during the operation of the cabinet. There are different numbers of heat dissipation slots at the upper and lower ends of the cabinet. When the electrical components in the cabinet generate heat, the heat rises and is discharged through the upper slots. The cold air is continuously supplemented into the cabinet through the lower slots, so that the sealed cabinet forms a natural ventilation channel from bottom to top to achieve the purpose of heat dissipation.
3. In accordance with the requirements of modern industrial product modeling design, the GGD cabinet adopts the golden ratio method to design the cabinet shape and the division dimensions of each part to make the entire cabinet beautiful and generous.
4. The cabinet door is connected to the frame with a rotating shaft movable hinge, which is easy to install and disassemble. A mountain-shaped rubber and plastic strip is embedded at the hem of the door. When closing the door, the strip between the door and the frame has a certain compression stroke, which can prevent Direct collision between the door and the cabinet, it also improves the protection grade of the door.
GGD
AC low voltage distribution cabinet
5. The instrument door equipped with electrical components is connected to the frame with multiple strands of soft copper wires. The mounting parts in the cabinet are connected to the frame with knurled gaskets, and the entire cabinet forms a complete grounding protection system
6. The cabinet surface paint can be treated with polyester orange-shaped baking paint or plastic powder spray process. Both have the characteristics of strong adhesion and good texture. The entire cabinet has a matt tone, which avoids the glare effect and creates a more comfortable visual environment for the personnel on duty.
7. The top cover of the cabinet can be removed when needed to facilitate the assembly and adjustment of the main busbar on site. The four corners of the top of the cabinet are equipped with lifting rings for lifting and shipping.
8. The protection level of the cabinet is IP30, and users can also choose between IP20 and IP40 according to the requirements of the use environment
KYN28-12
Indoor metal armored center-mounted removable switchgear
Description
KYN28-12 series indoor metal armored center-mounted removable switchgear is a three-phase AC 50Hz single bus segment system or double bus segment system indoor complete power distribution device. It is used to receive and distribute 3.6-12kV network power, and Implement control, protection, monitoring and measurement of power circuits.
KYN28-12 series switchgear includes all solution products with rated stable current from 16kA to 50KA, rated current of main bus and branch bus from 630A to 3150A. Its products all comply with national GB3906, DL403, DL404 standards and international IEC298 standards.
The KYN28-12 series switch cabinet is a fully assembled mid-mounted structure. The cabinet body is made of 2mm aluminum-zinc steel plate, processed by CNC processing equipment, and connected by high-strength bolts. The cabinet has a reasonable layout, complete functions, and has the ability to prevent misoperation. Circuit breaker, prevent the handle cart with load, prevent the grounding switch from being closed with electricity, This switchgear can be equipped with domestic vacuum circuit breaker and vacuum contactor, as well as foreign products of the same type. Its compact structure, high interchangeability of hand carts, ample cable room space, convenient maintenance, and its overall performance reaches the advanced level of foreign similar products. On this basis, the F-C circuit switchgear developed and produced is a new type of power distribution device that combines high voltage fuse with vacuum contactor, and has the advantages of compact structure, small volume, low noise, high reliability, and long-distance remote control operation in the central control room. This product can be widely used in metallurgy, petrochemical, power plant and other departments, and is mainly used to control and protect motors, transformers and capacitor banks.
KYN28 series switch cabinet consists of cabinet body and functional unit compartments installed with different electrical components. See Figure 1
A. Instrument room B. Handcart room C. Cable room D. Busbar room
1. Cabinet body 2. Circuit breaker handcart3. heater 4. secondary socket and interlock
5. Valve mechanism6. Contact box7, bus sleeve 8. main bus bar and branch bus bar
9. Current transformer 10. grounding switch 11. primary cable 12. lightning arrester
13. Grounding bus
KYN28-12
Indoor metal armored center-mounted removable switchgear
1. Cabinet
The KYN28 series switchgear cabinet body and each functional unit are made of 2mm aluminum-zinc steel plate, processed by CNC machining equipment, and connected with high-strength bolts. (See Figure 2) Its products are very suitable for mass production and assembly, with dimensional accuracy is guaranteed, good interchangeability, all materials have strong oxidation and corrosion resistance, and have higher strength and stiffness than welding cabinets. The overall design meets the IP4X protection grade.
2. Functional unit
The KYN28 series switch cabinet has four functional unit compartments, namely the handcart room, busbar room, cable room and position table room. They are separated from each other by metal plates. See Figure 1
●Trolley room
The trolley room is equipped with a specific guide rail, so that the trolley can slide and work in it. The trolley has a working position and a test position (isolation position). When the trolley enters the working position from the testing position, the valve blocked on the fixed contact box will be pushed open, so that the moving contact of the trolley will be inserted into the fixed contact. When the trolley is pulled out, the valve will automatically drop again, which can prevent the operator from touching the live body. When the trolley is pulled out, the operator can also lock the valve to prevent the trolley from being pushed open and accidents occur. The trolley room can be equipped with circuit breaker trolley, voltage transformer trolley, isolation trolley and meter measuring trolley.
The trolley can be operated when the switch cabinet door is closed, and the position of the trolley and the status sign of the trolley can also be seen through the observation window on the door. Even if the door of the trolley compartment is opened, its protection level can still reach IP2X.
KYN28-12
Indoor metal armored center-mounted removable switchgear
Busbar room
The design of the bus room fully considers the installation mode of the main bus during the installation construction by users, so that the construction workers can conveniently install the bus by opening the rear baffle plate without climbing to the top of the cabinet.
The baffle plate between the segmented busbar passes through the cabinets is the wall bushing made of insulating and flame-retardant material, which can not only support the main busbar, but also limit the spread of the situation when an internal fault occurs.
Cable room
The cable room has abundant space to install and overhaul current transformers, grounding switches, lightning arresters and cables
The usage of cables can reach up to three to six groups. In the design, the special requirements of users are also taken into account, so that the installation height of the electrical system can reach more than 750mm. See Figure 1 The bottom plate structure of the cable room is also very suitable for construction workers to conveniently install cables.
Instrument room
The instrument room can be equipped with relay protection components, instruments and other secondary equipment. The relay screen is pre-opened with installation holes to conveniently install the relay components. The control cable is laid in the wiring slot with sufficient space and is covered by a metal cover plate. The left wiring slot is reserved for the lead in and lead out of the control wire.
The control wire of the switchgear itself is laid on the right side, and the control wire crossing hole is opened on the side panel of the instrument room for construction.
●Pressure relief device
There are pressure release devices above the trolley room, bus room and electrical system room. When an internal fault occurs in the cabinet and arcs occur, the sharply rising air pressure will quickly open the release device so that the internal gas can be discharged in time, ensuring the safety of operators and switchgear. cabinets.
KYN28-12
Indoor metal armored center-mounted removable switchgear
When the switch cabinet is working normally, the special structure of the pressure release device can help dissipate heat, so that the temperature rise of each part of the primary circuit in the cabinet can always be kept within the normal working range.
Interlocking device
The KYN28 series switchgear is also equipped with a flexible and reliable five-protection interlocking device, which provides a reliable guarantee for preventing accidents and the safe operation of the equipment. When the grounding switch is in the opening position, the trolley can be pushed from the testing position to the working position, and the circuit breaker trolley can only be pulled-in or pulled-out when it is opened; When the circuit breaker trolley is in the testing position or working position, the closing and opening operation can be carried out; When the trolley is in the working position, the grounding switch cannot be closed and the secondary plug cannot be pulled out; When the grounding switch is closed, the trolley cannot be pushed to the working position.
Grounding device
Connecting the main grounding busbars of each cabinet together with the preset connecting board.
Connecting all the leads to be grounded in the switchgear.
Connecting the foundation frame with the grounding bars. If there are more than 10 cabinets arranged, there must be more than two grounding bars.
Connecting the grounding wire of the grounding switch with the main grounding bus of the switchgear.
KYN28-24
Armored removable metal closed switchgear
Description
1. Scope of application and main uses
KYN28-24 armored removable AC metal-enclosed switchgear (hereinafter referred to as switchgear) is suitable for indoor three-phase 50/60 Hz, rated voltage 24KV power systems. It is mainly used in power plants, substations, industrial and mining enterprises and high-rise buildings, as receiving and distributing electric energy and controlling, protecting and monitoring circuits.
KYN28-24 switchgear has various functions to prevent misoperation, including preventing the trolley from moving with load, preventing the grounding switch from closing the circuit breaker when it is closed, preventing the grounding switch from being closed with electricity, and preventing mistakenly entering the live compartment. KYN28-24 switchgear is equipped with ZN73 series mid-mounted high-voltage AC vacuum circuit breaker and solid-sealed vacuum switch with excellent performance. The secondary circuit of the switchgear is equipped with advanced and reliable control and protection components; The bus is insulated by heat shrinkable insulation material or epoxy coating, the electrode shape is optimized, and the cabinet structure is compact. KYN28-24 switchgear is a power distribution equipment with advanced technology, stable performance, reasonable structure, easy use, safety and reliability.
2. Product reference standards
(a) GB1984 High Voltage AC Circuit Breaker.
(b) GB3906 3 \~ 35KV AC metal enclosed switchgear.
(c) Common technical requirements of GB/T11022 standards for high-voltage switchgear and control equipment.
(d) DL/T404 Indoor AC high voltage switchgear ordering technical conditions.
(e) DL/T593 Technical guidelines for common ordering of high voltage switchgear.
3. Use environmental conditions
Normal use conditions
(a) Ambient temperature: maximum temperature: + 40 °C, minimum temperature:-15 °C, and the average value measured within 24 hours does not exceed 35 °C.
(b) Humidity conditions are as follows:
-the average daily relative humidity does not exceed 95%;
-the average daily water vapor pressure does not exceed 2.2 kpa: the average monthly water vapor pressure does not exceed 1.8 kpa;
Condensation occasionally occurs under such conditions;
(c) the altitude does not exceed 1000m;
(d) the ambient air is not significantly contaminated by dust, smoke, corrosive and/or combustible gases, vapors or salt spray;
(e) Vibration or ground motion from outside the switchgear and control equipment is negligible;
(f) The magnitude of electromagnetic interference induced in the secondary system does not exceed 1.6 KV.
Special conditions of use
When used under normal environmental conditions exceeding the specifications of GB/T11022, the company and users can negotiate and reach an agreement on special operating conditions exceeding the normal operating conditions. In order to prevent condensation, the switchgear is equipped with a heater. When the switchgear is in standby state, it should be put into use. When the switchgear is operating normally, attention should also be paid to putting the heater into operation.
KYN28-24
Armored removable metal closed switchgear
Technical parameter
1. Main technical parameter to see below table
| No. | Name | Unit | Parameter | ||||
| 1 | Rated voltage | kV | 24 | ||||
| 2 | Rated frequency | Hz | 50/60 | ||||
| 3 | Ratedinsulationlevel | 1min power frequency withstand voltage(effective value) | kV | Interphase | 60 | Insulation | 79 |
| Lightning impulse withstand voltage(peak value) | kVto | ground | 125 | Fracture | 145 | ||
| Power frequency withstand voltage ofauxiliary control circuit | V | 2000 | |||||
| 4 | Rated current | A | 630、1250、1600、2000、2500 | ||||
| 5 | Rated short-circuit breaking current | kA | 20 | 25 | |||
| 6 | Rated short-time closing current (peak value) | kA | 50 | 63 | |||
| 7 | Rated short-time withstand current (4s) | kA | 20 | 25 | |||
| 8 | Rated peak value withstand current | kA | 50 | 63 | |||
| 9 | Rated voltage of auxiliary control circuit | V | DC or AC 110/220 | ||||
| 10 | Protection grade | IP4X (Circuit breaker doors open or isolatecompartment IP2X | |||||
| 11 | Overall dimension (W×D×H) | mm | 800x1810x2380 | 1000x1810x2380 | |||
| 12 | Weight | kg | 840~1440 | ||||
2. Main technical parameter of ZN73-24 Vacuum circuit breaker
| No. | Name | Unit | Parameter | |
| 1 | Rated voltage | kV | 24 | |
| 2 | 1min power frequency withstand voltageRated (effective value)insulationlevel Lightning impulse withstand voltage(peak value) | kV | 60 | |
| kV | 125 | |||
| 3 | Rated frequency | Hz | 50/60 | |
| 4 | Rated current | A | 630、1250、1600、2000 | 630、1250、1600、2000、2500、3150 |
| 5 | Rated short-circuit breaking current | kA | 20 | 25 |
| 6 | Rated short-time closing current (peak value) | kA | 50 | 63 |
| 7 | Rated short-time withstand current (4s) | kA | 20 | 25 |
KYN28-24
Armored removable metal closed switchgear
| 8 | Rated peak withstand current | kA | 50 | 63 |
| 9 | Rated single capacitor bank breakingcurrent | kA | 630 | |
| 10 | Rated back-to-back capacitor bankbreaking current | V | 400 | |
| 11 | Rated short circuit breaking currentbreaking cycles | cycles | 50 | |
| 12 | Mechanical life | cycles | 20000 | |
| 13 | Rated operating sequence | 0-0.3s-CO-180s-CO | ||
3. Technical parameters of spring operating mechanism
| No. | Name | Unit | Parameter | |
| 1 | Rated operation | Closing tripping coil | V | AC220、AC110、DC220、DC110 |
| voltage | Opening tripping coil | |||
| 2 | Working current | Closing tripping coilOpening tripping coil | A | AC 220 or DC 220: 1.1AC 110 or DC 110: 3.1 |
| 3 | Energy storage motor power | W | 80、110 | |
| 4 | Energy storage motor Voltage | V | AC220、AC110、DC220、DC110 | |
| 5 | Motor energy storage time | S | ≤ 10 | |
KYN18A-12
Indoor AC armored removable metal closed switchgear
Description
KYN18A-12 indoor AC armored removable metal enclosed switchgear (hereinafter referred to as switchgear). It is a mid-mounted vacuum switchgear. The vacuum switch mainly uses ZN22B-12 vacuum circuit breaker, and can also be equipped with ZN12-10 vacuum circuit breaker. Circuit breaker and 3AF, 3AH vacuum circuit breaker.
This product complies with standards such as GB3906-91 "3-35kV AC Metal Enclosed Switchgear" DL404-91 "Technical Conditions for Ordering and Receiving Indoor AC Switchgear" and IEC298 "AC Metal Enclosed Switchgear and Control Equipment". It is suitable for 3-It is used to receive and distribute electric energy in 10kV AC three-phase 50Hz single bus power system. It can be widely used in various types of power plants, substations and industrial and mining enterprises. This product is reliable for wall installation (not recommended) and not against the wall.
Model No. and its implication
K Y N 18 A-12 / Rated breaking current (KA) Current Rating (A) Environmental characteristics: humid tropical zone TH, dry tropical zone TA, ordinary type no remark Main Circuit Scheme Number Rated voltage Modification code Design code Indoor type Removable type Metal armored closed switchgear
Technical parameter
| Name | Unit | Parameter(3)、6、10、12 | ||
| Rated voltage | kV | |||
| Rated short circuit breaking current | kA | 31.5 | 40 | 50 |
| Rated current | A | 1250、1600、2000、2500 | 1600、2000、3150 | |
| 4s rated thermally stable current | kA | 31.5 | 40 | 50(3s) |
| Rated dynamic stable current | kA | 80 | 100 | 125 |
| Rated lightning impulse withstandvoltage | kA | 75 | ||
| Rated 1min power frequencywithstand voltage | kA | 42 | ||
| Protection level of enclosure andcompartment | IP30 | |||
KYN18A-12
Indoor AC armored removable metal closed switchgear
| Name | Unit | Parameter12 | ||
| Rated voltage | kV | |||
| Rated current | A | 1250, 1600, 2000, 3150 | 1600, 2000, 3150 | |
| Rated short-circuit breaking current | kA | 31.5 | 40 | 50 |
| Rated short-circuit closing current | kA | 80 | 100 | 125 |
| Rated thermal stable current | kA | 31.5/4s | 40/4s | 50/3s |
| Rated dynamic stable current | kA | 80 | 100 | 125 |
| Rated short-circuit breaking cycles | cycles | 50 | 30 | 30 |
| Rated operation sequence | 0-0.3s-CO-180s-CO | 0-180s-CO-180S-CO | ||
| Name | Unit | Parameter |
| Rated voltage | kV | 10 |
| Rated current | A | 2000 |
| Rated short-circuit breaking current | kA | 31.5 |
| Rated short-circuit closing current | kA | 80 |
| Rated thermal stable current (4s) | kA | 31.5 |
| Rated dynamic stable current(peak value) | kA | 80 |
| Rated short-circuit breaking cycles | cycles | 50 |
| Breaking single capacitor groupcurrent | A | 630 |
| Mechanical life | cycles | 10000 |
| Rated operation sequence | O-0.3s CO-0.3s-CO |
Part technical parameters of LZZBJ9-10A current transformer
| Rated primarycurrent leA | Accuracy and relative rated output VA | 1s thermalstable currentIthKA | Dynamicstablecurrent kA | |||
| 0.2 | 0.5 | 1 | 10P10 | |||
| 15, 20, 30, 40, 50 | 10 | 20 | 15 | 400Ie | 2.5Ith | |
| 60 | 10 | 15 | 15 | 21 | 52.5 | |
| 75 | 10 | 20 | 15 | 31.5 | 80 | |
KYN18A-12
Indoor AC armored removable metal closed switchgear
| 100 | 10 | 20 | 15 | 45 | 112.5 | |||
| 150, 160 | 10 | 20 | 15 | 63 | 130 | |||
| 200 | 15 | 30 | 15 | |||||
| 300 | 10 | 20 | 15 | |||||
| 400 | 10 | 20 | 20 | |||||
| 500 | 15 | 30 | 20 | 80 | 160 | |||
| 600 | 15 | 30 | 20 | |||||
| 750,800 | 10 | 30 | 60 | 20 | ||||
| 1200, 1250 | 20 | 30 | 60 | 30 | ||||
| 1500, 1600 | 20 | 30 | 60 | 15 | ||||
| 2000 | 20 | 30 | 60 | 20 | 100 | 160 | ||
| 2500 | 20 | 30 | 60 | 20 | ||||
| 3000;3150 | 30 | 60 | 90 | 10P15, 30 | ||||
| Rated primary current leA | Accuracy and relative rated output VA | |||
| grade 0.2 | grade 0.5 | grade 1 | grade 10P15 | |
| 1000, 1200, 1500 | 40 | 40 | 40 | 25 |
| 2000, 3000, 4000, 5000, 6000 | 60 | 60 | 60 | 35 |
Technical parameters of JDJZ-10 voltage transformer
| Model No. | JDZJ-3 | JDZJ-6 | JDZJ-10 |
| Frequency (Hz) | 50 | ||
| Rated voltage ratioV | 3000 100 1003 3 N32 | 6000 100 1003 3 3√ | 10000,100 1003 3 3N |
| Rated secondary output VA0.513 | 305080 | 50 | 50 |
| 80 | 80 | ||
| 200 | 200 | ||
| Max. output (VA) | 200 | 400 | 400 |
| Rated insulation level (kV) | 3.5/23/40 | 6.9/32/60 | 11.5/42/75 |
KYN18A-12
Indoor AC armored removable metal closed switchgear
| Model No. | JDZ-3 | JDZ-6 | JDZ-10 |
| Frequency (Hz) | 50 | ||
| Rated voltage ratioV | 1000/100; 2000/1003000/100 | 6000/100 | 10000/100 |
| Rated secondary output VA0.513 | 305080 | 5080200 | 5080300 |
| Max. output (VA) | 200 | 400 | 400 |
| Rated insulation level (kV) | 3.5/23/40 | 6.9/32/60 | 11.5/42/75 |
Technical parameters of relay equipped with LXK-20 zero-sequence current transformer 5. The cable outlet cabinet can be equipped with a zero-sequence transformer according to user needs. Generally, it is equipped with an LXK-0120 zero-sequence transformer (the maximum diameter of the cable is 120mm). The technical parameters of the relay are shown in the table below.
| Relay Model No. | Connection mode of relay coils | Relay scale value | Primary zero sequencecurrent value (A) |
| DD-11/60 | In series | 15×1 | 2.4-4.5 |
| 30×1 | |||
| Paralleling | 15×1 | 3-5 | |
| 30×1 | |||
| DD-1/60 | In series | 15×1 | 3-5 |
| 30×1 | |||
| Paralleling | 15×1 | 3-6 | |
| 30×1 |
Technical parameters of grounding switch
6. See the following table for the technical parameters of the grounding switch
| Name | Unit | Parameter |
| Rated voltage | kV | 10 |
| Maximum operating voltage | kV | 12 |
| 4s rated thermally stable current | kA | 31.5, 40 |
| Rated dynamic stable current | kA | 80,100 |
XGN15-12(L·R)
Box-type fixed indoor AC metal closed switchgear
Description
XGN15-12 (L)/T630-25 and XGN15-12 (L · R)/T100-31. 5 box-type fixed AC metal-enclosed switchgear are mainly used for ring network power supply or double radiation power supply of three-phase AC 50Hz and rated voltage 10kV power systems. It can also be used for terminal power supply as electric energy control and protection device for electrical equipment. It is also suitable for installation in box-type substations, especially compact box substations.
Model No. and its implication
X G N15 -12(L·R) D— With motor operation mechanism Scheme No. (F): With load switch, (F·R) with Load switch-fuse combined electrical products Rated voltage: kV Design No. Using places: indoor Fixed type Box type
| No. | Name | Unit | Parameter | |
| XGN15-12(L·R) | ||||
| 1 | Rated voltage | kV | 12 | |
| 2 | Rated frequency | Hz | 50 | |
| 3 | Rated insulation level | 1min power frequencywithstand voltage | kV | To ground and interphase 42,Isolation fracture 48 |
| Lightning impulsewithstand voltage | kV | To ground and interphase 75,Isolation fracture 85 | ||
| 4 | Main busbar rated current | A | 630 | |
| 5 | Rated current | A | 630 | |
| 6 | Rated closed-loop breaking current | A | 630 | |
| 7 | Rated active load breaking current | A | 630 | |
| 8 | Rated cable charging breaking current | A | 10 | |
| 9 | Rated transfer current | A | ||
| 10 | Breaking No-load transformer capacity | kVA | 1250 | |
XGN15-12(L·R)
Indoor AC armored removable metal closed switchgear
| No. | Name | Technical | parameter | ||
| XGN15-12L | XGN15-12(L·R) | ||||
| 11 | Rated closing current | kA | 63 | ||
| 12 | Rated short-time withstand current (2s) | kA | 25 | ||
| 13 | Rated peak value withstand current | kA | 63 | ||
| 14 | Rated short-circuit breaking current | kA | 31.5(expect) | ||
| 15 | Peak value withstand current of grounding circuit | kA | 63 | ||
| 16 | Short-time withstand current of grounding circuit (2s) | kA | 25 | ||
| 17 | Suited fuse model No. | S □LAJ | |||
| 18 | Rated voltage of auxiliary circuit | V | =220,-110 | ||
| 19 | Protection grade | IP3X | |||
| 20 | Mechanical life | Load switch | Cycles | 5000 | |
| Grounding switch | Cycles | 2000 | |||
Foundation installation dimensions
| Scheme No. | 001 005 009 010 011 012 | 002 003 004 0 | 06 007 008 | 013 014 | 015 |
| Cabinet width a | 375 | 500 | 625 | 750 | 800 |
| Installation holecabinet c | 335×770 | 460×770 | 585×770 | 710×770 | 760×770 |
| Foundationdimension c | 188 | 288 | 400 | ||
HXGN15-12(F·R)
Boxed type Fixed AC Metal Closed Ring Main Switchgear
Description
HXGN15-12 (F · R) box-type fixed AC metal closed ring gateway equipment (referred to as ring network cabinet for short) is a new type of high-voltage switchgear produced for the transformation and construction of urban power grid. It is also used for breaking load current and short-circuit current and closing short-circuit current in power supply system. This ring network cabinet is equipped with vacuum load switch, and its operating mechanism is spring operating mechanism, which can be operated manually or electrically. The grounding switch and isolation knife are equipped with manual operating mechanism.
| No. | Name | Unit | Parameter | |
| 1 | Rated voltage | kV | 12 | |
| 2 | Rated current | Load switchgear | 630 | |
| Combined electrical cabinet | 125 | |||
| 3 | Rated short-circuit closing current (peak value) | kA | 50 | |
| 4 | Rated short-circuit breaking current | kA | 31.5 | |
| 5 | Rated active load breaking current | A | 630 | |
| 6 | 4s thermal stable current | kA | 20 | |
| 7 | Rated dynamic stable current (peak value) | kA | 50 | |
| 8 | 1min power frequency withstand voltage | kV | 42(fracture, 48) | |
| 9 | Lightning impulse withstand voltage | kV | 75(fracture, 85) | |
| 10 | Mechanical life | cycles | 10000 | |
HXGN15-12(F·R)
Boxed type Fixed AC Mental Closed Ring Main Switchgear
| No. | Name | Unit | Parameter |
| 11 | Rated handover current | A | 3150 |
| 12 | Operational mode | Manual or motor | |
| 13 | Protection grade | IP2X |
Structure characteristics
1. Structural performance characteristics
The outer shell of the ring main cabinet consists of a basic skeleton, a top plate, a panel and a side plate. The top of the ring main cabinet is the busbar room, and the front of the busbar room is the instrument room. The two rooms are separated by steel plates. The upper part of the cabinet is the load switch room, and the middle and lower parts are the cable inlet and outlet lines and other component rooms. The main equipment of the ring main cabinet includes vacuum load switch, isolation switch (or isolation knife switch with fuse), grounding switch, lightning arrester, operating mechanism, interlocking mechanism and measurement and metering circuit (see the figure below).
2. Operating mechanism
3. Wall sleeve
4. Insulator
5. Fuse (isolation knife)
6. Spring operation mechanism
7. Load switch
8. Current transformer
The ring main cabinet is equipped with FN25-12 high-voltage vacuum load switch, which is used to break the fault and overload current. The isolating switch, vacuum switch, grounding switch and cabinet door composed of the switch are interlocked with each other according to a certain program, which can effectively prevent misoperation; The vacuum switch cabinet is equipped with a motor-spring energy storage operating mechanism to achieve rapid closing and opening operations. It can be equipped with certain protective relays according to user requirements. The fuse combination electrical cabinet has a fuse pipe with a firing pin, in case of short circuit, the firing pin hits the tripping mechanism to achieve rapid opening and closing, which can effectively protect electrical equipment.
HXGN15-12(F·R)
Boxed type Fixed AC Mental Closed Ring Main Switchgear
2. The functional unit ring main cabinet is mainly equipped with FN25-12D two-station vacuum load switch. The main solutions are incoming cabinet and outgoing cabinet.
The incoming cabinet solution is equipped with an FN25-12D two-station vacuum load switch in the cabinet, and the cabinet can also be flexibly equipped with CT and PT. The main circuit is controlled by an FN25-12D vacuum load switch equipped with an isolation knife and a grounding knife, which can reach three stations of bus connection, isolation and grounding respectively.
The outlet cabinet solution is equipped with an FN25-12 D · R two-station vacuum load switch and a fuse equipped with an impactor in the cabinet, and CT, PT and ZnO arresters can be flexibly assembled in the cabinet, thus eliminating the need for metering cabinet.
3. “Five protection” locking function
● Power transmission operation: only when the cabinet door is closed and locked, and the grounding switch is operated to the "open" position, can the load switch be operated to the closed position.
●Power outage operation: When the load switch is in the isolated position, the grounding switch can be closed. When the grounding switch is in the closed position, the cabinet door can be opened by inserting the insulating partition in place.
There is reliable interlocking between the vacuum interrupter chamber and the isolation knife, while the isolation knife and the grounding knife are linked with each other and interlocked with the cabinet door, and the insulation partition and the cabinet door are also interlocked.
Overall and installation dimension
ZBW
Series Combined substation
Description
ZBW series combined substations, commonly known as European-style box substations, combine highvoltage electrical equipment, transformers, low-voltage electrical equipment, etc. into compact complete sets of power distribution devices, which are used in urban high-rise buildings, urban and rural buildings, residential areas, high-tech development zones, small and medium-sized factories, mines, oil fields, and temporary construction electricity and other places for receiving and distributing electrical energy in the power distribution system.
ZBW series combined substations have the characteristics of strong complete set, small size, compact structure, safe and reliable operation, easy maintenance, and mobility. Compared with conventional civilbuilt substations, combined substations of the same capacity usually cover an area of only 1/10\~1/5 of conventional substations, which greatly reduces the design workload and construction volume, and reduces construction costs.In the power distribution series, it can be used in the ring network power distribution system, as well as in the dual power supply or radiation terminal power distribution system. It is a new type of complete set of equipment for the construction and re-selection of urban and rural substations.
ZBW series combined substations meet the standards of SD320-1992 "Technical Conditions for Box-type Substations" and GB/T17467-1997 "High-voltage/Low-voltage Prefabricated Substations".
| No. | Item | Unit | High voltage | Transformer | Low voltage |
| 1 | Rated voltage Ue | kV | 7.2、12 | 6/0.4、10/0.4 | 0.4 |
| 2 | Rated capacity Se | kvA | Type: 200~1250 | ||
| 3 | Rated current I | kvA | 200~630 | 100~3000 | |
| 4 | Rated breakingcurrent | A | Load switch 400~630A | 15~63 | |
| kA | Combined productsdepends on fuse | ||||
| 5 | Rated short-timewithstand current | kA | 20 (2S) | 200~400kvA | 15 (1S) |
| 12.5 (4S) | 400kvA | 30 (1S ) |
ZBW
Series Combined substation
| No. | Item | Unit | High voltage | Transformer | Low voltage |
| 6 | Rated peak withstandcurrent | kA | 31.5、50 | 200~400kvA | 30 |
| 400kvA | 63 | ||||
| 7 | Rated closing current | kA | 31.5、50 | ||
| 8 | Power frequencywithstand voltage1min. | kV | Phase to ground:42interphase: 30 | Oil: 35/5min | 2kV when ≤300V |
| Isolation fracture: 48, 34 | Dry: 28/5min | 2.5kV when≤300,660V | |||
| 9 | Lightningimpulse | kV | Phase to ground:75interphase: 60Isolation fracture: 85, 75 | 75 | |
| 10 | Noise level | dB | Oil: <55 | ||
| Dry: <65 | |||||
| 11 | Protection grade | IP33 | IP23 | IP33 | |
| 12 | Dimensions | Different dimensions are selected according to the selected transformercapacity and form. | |||
Product structure characteristics
1. This product is composed of a high-voltage power distribution device, a transformer and a low-voltage power distribution device connected, and is divided into three functional compartments, namely a high-voltage chamber, a transformer chamber and a low-voltage chamber. The high- and low-voltage chambers are fully functional, and the high-voltage side primary power supply system can be arranged into a variety of power supply methods such as ring network power supply, terminal power supply, and dual power supply. High-voltage metering devices can also be installed to meet the requirements of high-voltage metering. The transformer room can choose from S9 and S11 series low-loss oil-immersed transformers and SC(B) 9, SCR9, SC(B)10, and SCR10 series dry transformers; the transformer room is equipped with a self-starting forced air-cooling system and a lighting system, and the lowvoltage room can adopt a panel or cabinet-mounted structure according to user requirements to form the power supply scheme required by the user. There are various functions such as power distribution, lighting distribution, reactive power compensation, electrical energy metering and power measurement to meet the different requirements of users, and to facilitate users' power supply management and improve power supply quality
2. The high voltage chamber has a compact and reasonable structure, and has a comprehensive “five-protection' interlocking function to prevent misoperation. When the user has requirements, the transformer can be equipped with a track to easily enter and exit from the gates on both sides of the transformer room, and each room has automatic lighting devices. In addition, all the components selected in the high and low voltage rooms have reliable performance, easy operation, safe and reliable product operation, and easy operation and maintenance.
3. Two methods of natural ventilation and forced ventilation are used to make the ventilation and cooling good. Both the transformer room and the low-voltage room have ventilation ducts, and the exhaust fan has a temperature control device, which can be automatically started and turned off according to the set temperature to ensure the full load operation of the transformer.
4. The structure of the box can prevent rainwater and dirt from entering. It is made of special steel plate or aluminum alloy plate, which is anticorrosive and has the conditions for long-term outdoor use. Ensure anticorrosion, waterproof and dust-proof performance, long service life, and beautiful appearance.
ZBW
Series Combined substation
Layout form and overall dimensions
1. ZBW series box-type substations, divided according to the arrangement: "Mu" font arrangement (Figure 1-1, Figure 1-2):
"Pin" font arrangement (Figure 1-3, Figure 1-4);
The picture shows the floor layout of ZBW series box-type substation H-high voltage room T-transformer room L-low voltage room
2. Overall dimension to see figure 2, figure 3 and table 2
| Category | A | a | B | b | H | Suitable places | ||
| Threephase | “Mu” type | 100-630kvA | 4140 | 3750 | 2590 | 2290 | 2320 | Industry and mining,oil fields, construction, etc |
| 800-1250kvA | 5184 | 4880 | 2500 | 2290 | 2626 | Living quarters | ||
| “Pin” type | 50-400kvA | 2500 | 2300 | 2400 | 2200 | 2320 | ||
| Single | “Mu” type | ≤ 50kvA | 2500 | 2300 | 1260 | 1060 | 2215 | Street lamp |
| phase | 80-100kvA | 2500 | 2300 | 1840 | 1640 | 2215 | power supply | |