(30-SY fi From page 949)
®
[Option]
fi Flow Rate Characteristics
SY3000
SY5000
SY7000
SY9000
1.1
2.8
4.5
10
0.28
0.37
0.28
0.29
0.29
0.90
1.4
2.5
Series Flow rate characteristics
C [dm3
/(s·bar)] b Cv
fi Long servise life
∗ Please contact SMC if life test data is required.
Rubber Seal
SY3000/5000/7000/9000 Series
5 Port Solenoid Valve
∗ For details, refer to page 955.
The connection cable and various units for PLC connection in PC wiring
systems have been discontinued by the manufacturer. Therefore, while
they can no longer be provided, the valve manifold (manifold with built-in
valves) can still be ordered. For details, refer to the Web Catalog.
The EX510 series is to be discontinued. When designing new equipment
and facilities, consider using another series (EX260/EX600) instead.
723 A
Cylinder Speed Chart
AN202-02
AS3002F-08A
Body ported
SY9120-03
Tubing bore x Length
Speed controller
Silencer
CS1 series
SGP10A x 1 m
AS420-03
AN20-02
Conditions [When using SGP (steel pipe)]
Base mounted
SY7140-03
Tubing bore x Length
Speed controller
Silencer
CS1 series
SGP10A x 1 m
AS420-03
AN30-03
SY9140-04
Tubing bore x Length
Speed controller
Silencer
SGP15A x 1 m
AS420-04
AN40-04
Conditions [When using SGP (steel pipe)]
Series
SY3120-C6
SY5120-01
SY7120-02
SY9120-03
Average
speed
(mm/s)
800
700
600
500
400
300
200
1000
800
700
600
500
400
300
200
1000
800
700
600
500
400
300
200
1000
800
700
600
500
400
300
200
1000
Bore size
CJ2 series
Pressure 0.5 MPa
Load rate: 50%
Stroke 60 mm
CM2 series
Pressure 0.5 MPa
Load rate: 50%
Stroke 300 mm
MB, CA2 series
Pressure 0.5 MPa
Load rate: 50%
Stroke 500 mm
CS1 series
Pressure 0.5 MPa
Load rate: 50%
Stroke 1000 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160
Series
SY3140-01
SY5140-02
SY7140-03
SY9140-04
Average
speed
(mm/s)
Bore size
CJ2 series
Pressure 0.5 MPa
Load rate: 50%
Stroke 60 mm
CM2 series
Pressure 0.5 MPa
Load rate: 50%
Stroke 300 mm
MB, CA2 series
Pressure 0.5 MPa
Load rate: 50%
Stroke 500 mm
CS1 series
Pressure 0.5 MPa
Load rate: 50%
Stroke 1000 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160 ø180 ø200
∗ Cylinder is in extending. Speed controller is meter-out, which is directly connected with cylinder and its needle is fully opened.
∗ Average speed of cylinder is obtained by dividing the full stroke time by the stroke.
∗ Load factor: ( (Load mass x 9.8) /Theoretical force) x 100%
∗ The histograms with fi marked are the case when piping is done by using steel.
Use as a guide for selection.
Please confirm the actual conditions with SMC Sizing
Program.
Body ported
SY3120-C6
SY5120-01
SY7120-02
SY9120-03
Tubing bore x Length
Speed controller
Silencer
Tubing bore x Length
Speed controller
Silencer
Tubing bore x Length
Speed controller
Silencer
Tubing bore x Length
Speed controller
Silencer
CJ2 series CM2 series MB, CA2 series CS1 series
T0604 x 1 m –
–
–
–
–
–
–
–
–
T0604 x 1 m
T0604 x 1 m
AS2052F-06A
AN120-M5
AN101-01
AN110-01
AN20-02
T0604 x 1 m T1075 x 1 m T1209 x 1 m
T0806 x 1 m
AS3002F-06A
AS3002F-06A
AS3002F-06A AS4002F-10A AS4002F-12A
T1075 x 1 m
AS4002F-10A
Conditions
Body Ported
Base Mounted
Base mounted
SY3140-01
SY5140-02
SY7140-03
SY9140-04
Tubing bore x Length
Speed controller
Silencer
Tubing bore x Length
Speed controller
Silencer
Tubing bore x Length
Speed controller
Silencer
Tubing bore x Length
Speed controller
Silencer
CJ2 series CM2 series MB, CA2 series CS1 series
T0604 x 1 m –
–
–
–
–
–
–
–
–
T0604 x 1 m
T0604 x 1 m
AS3002F-06A
AN110-01
AN20-02
AN30-03
AN40-04
T0604 x 1 m T1075 x 1 m
T1075 x 1 m
T1209 x 1 m
AS3002F-06A AS4002F-10A AS4002F-12A
T1209 x 1 m
T0806 x 1 m
AS3002F-06A AS3002F-08A
AS3002F-06A AS4002F-10A
Conditions
Perpendicular,
upward actuation
Horizontal actuation
800
700
600
500
400
300
200
1000
800
700
600
500
400
300
200
1000
800
700
600
500
400
300
200
1000
800
700
600
500
400
300
200
1000
fi fi
fi fi
fi fi fi fi
Perpendicular,
upward actuation
Horizontal actuation
A 724
Valve Variations
Note 1) All AC voltage models have built-in surge voltage suppressor.
Note 2) Body ported external pilot type (made to order) is not available for DIN terminal.
Note 3) Only available for DIN terminal and M8 connector.
Note 4) SY3000 does not have a DIN terminal which can be connected to a manifold.
Series
0.65
2.4
3.3
1.1
2.8
4.5
8.6
10
P.732
P.748
Body ported Base mounted
Actuation Voltage Note 1)
Note 4)
Electrical entry
Single Double Closed center Exhaust center Pressure center Grommet L plug connector M plug connector DIN terminal Light/surge voltage suppressor
2 position 3 position DC
24 V
12 V
6 V
5 V
3 V
AC
100 V
50/60 Hz
110 V
50/60 Hz
200 V
50/60 Hz
220 V
50/60 Hz
Sonic
conductance
C [dm3/(s·bar)]
4/2→5/3
(A/B→EA/EB)
SY3 20
SY5 20
SY7 20
SY3 40
SY5 40
SY7 40
SY9 20
SY9 40
M8 connector
{ }
Standard Option Made to order (Refer to page “Made to Order”.)
PE
A B
C4 C6 C8 C10 N3 N7 N9 N11
(EA, EB)
External
Pilot
(Note 2)
External
pilot
Subplate
External
Pilot
(Note 2)
External
pilot
External
Pilot
(Note 2)
External
pilot
DIN
terminal
M8
connector
DIN
terminal
M8
connector
(P)
C12
Series
Body ported Base mounted
SY3 20
SY5 20
SY7 20
SY3 40
SY5 40
SY7 40
SY9 20
SY9 40
Manual
override A, B port size
One-touch fitting
Valve option P, EA, EB
port size
Non-locking push type Push-turn locking slotted type Push-turn locking lever type Bracket Exhaust throttle Oil resistant (Other than designated turbine oil) Vacuum specifications Low pressure specifications Dual pressure Enclosure IP65 Interface regulator 3 Port valve SY
38 1 4 1 M5 8 38 1 2 1 2 1 4 1 M5 8
Note 3)
725
Manifold Variations
P. 766
P. 776
Type 20
P. 772
Type 23
P. 782
Type 23P
P. 792
Type 23SA
Type 20P
P. 800
Type 60
SY3fi20
SY5fi20
SY7fi20
SY3fi20
SY5fi20
SY7fi20
SY3fi60
SY5fi60
SY7fi60
Note)
In common
Note)
In common
SY9fi20
SY9fi20
SY9fi20
P. 786
Type 20SA SY3fi20
SY5fi20
SY7fi20
Manifold Variations
5 port
Wiring
Individual wiring Flat ribbon cable (26 pins) Flat ribbon cable (20 pins) connector box Plug-in type D-sub connector (25 pins) Plug-in type flat ribbon cable (26, 20, 10 pins) Plug-in type terminal block (9, 18 pins) Serial transmission unit Positive common Negative common
Connection Common specifications
Valve
Series
Body ported
Bar stock type
Individual wiring
ff Direct piping to the main unit of
a valve. Combination of
different fittings is possible.
Bar stock type
Flat ribbon cable
ff A 26 pins MIL connector
permits One-touch wiring of
external cables in a bundle.
Stacking type
Individual wiring
ff Manifold stations can be increased or decreased.
Stacking type
Flat ribbon cable
ff Manifold stations can be increased or decreased.
Cassette type
Individual wiring
ff Size and weight reduced by
eliminating the manifold base
Bar stock type
EX510 gateway type
ff Can be used with a serial
transmission system.
Stacking type
EX510 gateway type
ff Can be used with a serial
transmission system.
+– +– +– +–
P EB EA
P EB EA
+– +– +– +–
EA P EB
+– +– +– +–
EA P EB
+– +–
P
R
Standard Option Made to order (Refer to page “Made to Order”.)
Note) When there are polarities, the positive common specifications are used.
6
7
14
15 9
8
1
0
COM
PWR
EB PEA
9
8
15
14
7
6
1
0
COM
PWR
726
Manifold option A, B port size
One-touch fitting
Valve option
C4 C6 C8 C10 N3 N7 N9 N11
Individual SUP
block disk
Individual SUP
block disk
Individual SUP
block disk
External
pilot
External
pilot
External
pilot
Individual
SUP
interface
Individual
SUP
interface
Individual
SUP
block disk
Individual
SUP
block disk
Individual SUP
block disk
Individual SUP
block disk
Individual SUP
block disk
Individual
SUP
block disk
Individual
SUP
interface
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
P.795 pilot
P.795
P.795
P.795
P.795
P.795
P.795
P.795
P.795
P.795
P.795
P.795
Individual
EXH
interface
Individual
EXH
Individual
EXH
Individual
EXH
Individual
EXH
interface
Individual
EXH
interface
C12
P.806
P.806
P.806
P.797
P.797
P.806
P.806
P.806
P.797
P.797
P.806
P.806
P.806
P.797
P.797
P.806
P.806
P.806
Note)
Note)
Note)
Note)
Note)
Note)
Note)
SY300
SY500
P.795
P.795
P.795
P.795
P.795
P.795
Note) When using DIN terminal or M8 connector. SY3000 does not have a DIN terminal which can be connected to a manifold.
Manifold Variations
Blanking plate Individual SUP spacer Individual EXH spacer SUP block disk EXH block disk Label for block disk Silencer for One-touch fitting Built-in silencer Connector M5 Mixed mounting Vacuum specifications Low pressure specifications Different pressure Dual pressure Exhaust throttle Bundle wiring Mixed fitting sizes IP65 enclosure Interface regulator
1 4 1 8
SY3000
SY5000 Oil resistant (Other than designated turbine oil) Valves with function/Vacuum release valve with restrictor 3 Port valve/Mixed mounting
3 8
727
Manifold Variations
P. 818
P. 834
P. 818
P. 834
P. 864
P. 884
P. 876
P. 892
Type 41
Type 41P
P. 842
Type 43P
Type 42
P. 828
Type 43
Type 42P
P. 848
P. 853
Type 43SA
Type 42SA
Type 45
Type 45S6A
P. 920
Type 45S6B
SY3fi40
SY5fi40
SY7fi40
SY3fi40
SY5fi40
SY3fi40
SY5fi40
SY3fi40
SY5fi40
SY3fi40
SY5fi40
SY3fi40
SY5fi40
Note)
In common
Note)
In common
Note)
In common
SY9fi40
SY3fi40
SY5fi40
SY7fi40
SY9fi40
SY9fi40
SY3fi40
SY5fi40
SY3fi40
SY5fi40
SY3fi40
SY5fi40
SY7fi40
Manifold Variations
5 port
Wiring
Individual wiring Flat ribbon cable (26 pins) Flat ribbon cable (20 pins) connector box Plug-in type D-sub connector (25 pins) Plug-in type flat ribbon cable (26, 20, 10 pins) Serial transmission unit Positive common Negative common
Connection Common specifications
Valve
Series
Standard Option Made to order (Refer to page “Made to Order”.)
Base mounted
Type 45-NA
A
Type 45
Compact bar stock type
Individual wiring
ff The base mounting facilitates maintenance
after valves are changed.
Compact bar stock type
Flat ribbon cable
ff A 26 pins MIL connector permits one-touch
wiring of external cables in a bundle.
Bar stock type/Common external EXH
Individual wiring
ff The base mounting facilitates
maintenance after valves are changed.
ff Vacuum/low pressure combination
system is possible.
Bar stock type/Common external EXH
Flat ribbon cable
ff A 26 pins MIL connector permits one-touch
wiring of external cables in a bundle.
ff Vacuum/low pressure combination system
is possible.
Stacking type
Individual wiring
ff Manifold stations can be increased or decreased.
Stacking type
Flat ribbon cable
ff Manifold stations can be increased or decreased.
Stacking type/DIN rail mounted
Individual wiring
ff Stations can be increased on the DIN rail. Integrated
mounting of other electric parts is possible, too.
Stacking type/DIN rail mounted
Connector box
ff Stations can be increased or decreased on the DIN rail. The provided
connector box permits one-touch connection of electric cables.
Stacking type/DIN rail mounted
EX510 gateway type
ff Can be used with a serial
transmission system.
Stacking type/DIN rail mounted
Plug-in
ff Stations can be increased or decreased on the DIN rail.
ff A variety of centralized wiring methods are possible.
Stacking type/DIN rail mounted
Plug-in
EX510 gateway type
ff Can be used with a serial transmission system.
Bar stock type
EX510 gateway type
ff Can be used with a serial
transmission system.
Stacking type
EX510 gateway type
ff Can be used with a serial
transmission system.
+– +– +– +– EA
P
EB
+– +– +– +– EA P EB
EA P
EB
+– +– +– +– EA
P
EB
+– +– +– +–
+– +– +– +– +–
EB
P EA
9
8
15
14
7
6
1
0
COM
PWR
15
14
7
6
9
8
1
0
COM
PWR
PORT SOL.b
SOL.a
15
14
7
6
9 COM
PWR
Note) When there are polarities, the positive common specifications are used.
PE X
EB EA
P
6
7
14
15 9
8
1
0
COM
PWR
728
Manifold option A, B port size
One-touch fitting
Valve option
C4 C6 C8 C10 C12 N3 N7 N9 N11
Individual
SUP
interface
Individual
SUP
interface
Individual
SUP
interface
Individual
SUP
interface
Individual
SUP
spacer or
block disk
Individual
SUP
block disk
Individual
SUP
block disk
Individual
SUP
spacer or
block disk
Individual
SUP
spacer or
block disk
Individual
SUP
Individual
SUP
spacer or
block disk
Individual
SUP
spacer or
block disk
Individual
SUP
Individual
EXH
Individual
EXH
Individual
EXH
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
External
pilot
Note)
Note)
Note)
Note)
Note)
Note)
Note)
Note)
P.858
P.858
P.858
P.858
P.858
P.858
P.858
P.858
P.867
P.891
P.891
P.925
P.925
P.858
P.858
P.858
P.858
P.858
P.858
P.858
P.878
P.925
P.925
P.867
P.858
P.858
P.858
P.858
P.858
P.858
P.858
P.858
P.878
P.925
P.925
P.867
P.858
P.859
P.890
P.859
P.860
P.878
P.925
P.925
P.867
P.860
P.860
P.860
P.878
P.925
P.925
P.867
P.860
P.860
P.860
P.878
P.925
P.925
P.867
P.860
P.860
P.860
P.878
P.925
P.925
P.867
P.860
P.860
P.828
P.842
SY300
SY500
Manifold Variations
Note) When using DIN terminal or M8 connector. SY3000 does not have a DIN terminal which can be connected to a manifold. Mixed mounting Vacuum specifications Low pressure specifications Different pressure Dual pressure Exhaust throttle Bundle wiring Mixed fitting sizes IP65 enclosure Interface regulator
1 4 1 M5 8
SY3000
SY5000 Oil resistant (Other than designated turbine oil) 3 Port valve/Mixed mounting
3 8 Blanking plate Individual SUP spacer Individual EXH spacer SUP block disk EXH block disk Label for block disk Silencer for One-touch fitting Built-in silencer Connector
729
PE
A B
–+ –+ –+ –+
P EB EA
–+ –+ –+ –+
EA P EB
P EB EA
–+ –+ –+ –+
EA P EB
6
7
14
15 9
8
1
0
COM
PWR
EB PEA
9
8
15
14
7
6
1
0
COM
PWR
–+ –+
P
R
INDEX
5 Port Solenoid Valve
Single Unit
Body Ported Manifold
Cylinder Speed Chart ·························································································································································· P.724
Valve Variations ···································································································································································· P.725
Manifold Variations ······························································································································································· P.726
Body Ported ·································································································································· P.732
Base Mounted ······························································································································ P.748
Type 20 Bar Stock Type/Individual Wiring ······································································· P.766
Type 23 Stacking Type/Individual Wiring ········································································· P.772
Type 20P Bar Stock Type/Flat Ribbon Cable ···································································· P.776
Type 23P Stacking Type/Flat Ribbon Cable ······································································ P.782
Type 20SA Bar Stock Type/EX510 Gateway-type ······························································ P.786
Type 23SA Stacking Type/EX510 Gateway-type ································································ P.792
Type 60 Cassette Type/Individual Wiring ········································································· P.800
730
–+ –+ –+ –+ EA P EB
–+ –+ –+ –+ EA
P
EB
–+ –+ –+ –+ EA
P
EB
–+ –+ –+ –+
EA P
EB
EB
P EA
PE X
EB EA
P
6
7
14
15 9
8
1
0
COM
PWR
9
8
15
14
7
6
1
0
COM
PWR
–+ –+ –+ –+ –+
15
14
7
6
9
8
1
0
COM
PWR
PORT SOL.b
SOL.a
15
14
7
6
9 COM
PWR
Base Mounted Manifold
Type 41 Bar Stock Type/Compact Type/Individual Wiring ·········································· P.818
Type 42 Bar Stock Type/External Pilot Capable/Individual Wiring ···························· P.818
Type 43 Stacking Type/Individual Wiring ········································································· P.828
Type 41P Bar Stock Type/Compact Type/Flat Ribbon Cable ········································ P.834
Type 42P Bar Stock Type/External Pilot Capable/Flat Ribbon Cable ·························· P.834
Type 43P Stacking Type/Flat Ribbon Cable ······································································· P.842
Type 42SA Bar Stock Type/EX510 Gateway-type ······························································ P.848
Type 43SA Stacking Type/EX510 Gateway-type ································································ P.853
Type 45 Stacking Type/ DIN Rail Mounted Individual Wiring ······································· P.864
Type 45-A
NA Stacking Type/ DIN Rail Mounted Connector Box ·········································· P.876
Type 45S6A Stacking Type/ DIN Rail Mounted EX510 Gateway-type ······························ P.884
Type 45m Stacking Type/ DIN Rail Mounted Plug-in ························································· P.892
Type 45S6B Stacking Type/ DIN Rail Mounted EX510 Gateway-type ······························ P.920
Manifold Option ···································································································································································· P.925
SY300/500 3 Port Valve: Mixed Mounting Type on Manifold ···························································································· P.926
Made to Order
External Pilot/Built-in Silencer ············································································································································ P.934
Mixed Mounting Type ························································································································································· P.939
M8 Connector Conforming to IEC60947-5-2 ······················································································································ P.941
Body Ported External Pilot/Fluororubber for Main Valve ···································································································· P.942
Body Ported/Base Mounted 4-Position Dual 3-Port Valve ·································································································· P.942-1
Body Ported Vacuum Release Valve with Throttle Valve ··································································································· P.943
Pilot Valve Assembly/Port Block Assembly ······················································································································ P.948
Conforming to UL standard
30-SY3000/5000/7000/9000: 5 Port Solenoid Valve Body Ported/Single Unit ··································································· P.949
30-SY3000/5000/7000/9000: 5 Port Solenoid Valve Base Mounted/Single Unit ······························································· P.950
30-SY300/500: 3 Port Solenoid Valve Body Ported/Single Unit ························································································· P.951
30-SY300/500: 3 Port Solenoid Valve Base Mounted/Single Unit ····················································································· P.952
Specific Product Precautions ············································································································································· P.954
731 A
(EA) 5 1(P)3 (EB)
2 (B)(A) 4
(EA) 5 1(P)3 (EB)
2 (B)(A) 4
(EA) 5 1(P)3 (EB)
2 (B)(A) 4
(EA) 5 1(P)3 (EB)
2 (B)(A) 4
(A) 4 2 (B)
1
(P) (EA) 5 3 (EB)
Grommet L plug connector
24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12 VDC/
100, 110, 200, 220 VAC
M plug connector DIN terminal
24, 12 VDC
6, 5, 3 VDC
M8 connector
1
2 position single
2
2 position double
3
3 position closed center
4
3 position exhaust center
5
3 position pressure center
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC
For DC
Rated voltage
Type of actuation
Electrical entry
∗ DC specifications of type D, Y, DO and YO
is only available with 12 and 24 VDC.
∗ For type Wfi, DC voltage is only available.
Note) AC-type models that are CE/UKCA-compliant
have DIN terminals only.
Note) For details about Symbol of the
3 position type of the SY9000
series, refer to page 735.
∗ Power saving circuit is not
available in the case of D, DO,
Y, YO or Wfi type.
Nil Standard
T With power saving circuit
(24, 12 VDC only)
Coil specifications
– +
–+
–+
–+
–+
Note)
∗ LN, MN type: with 2 sockets.
∗ For DIN terminal of SY3000 series, refer to page
958.
∗ “Y” type is a DIN terminal conforming to
EN-175301-803C (former DIN43650C). For details,
refer to page 957.
∗ For connector cable of M8 connector, refer to page
960.
∗ M8 connector conforming to IEC60947-5-2 standard
is also available. Refer to page 941 for details.
∗ Refer to page 957 for the lead wire length of L and M
plug connectors.
∗ Refer to page 958 for the connector assembly with
cover for L and M plug connectors.
Note) Enter the cable length symbols in fi. Please be
sure to fill in the blank referring to page 961.
– + DC
AC
fi
—
fi
—
fi
—
fi
—
fi
fi
Note) AC-type models that are CE/UKCAcompliant have DIN terminals only.
Electrical entry for G, H, L, M, W
Nil Without light/surge voltage suppressor
S
Z
With surge voltage suppressor
With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
Electrical entry for D, Y
Nil Without light/surge voltage suppressor
S
Z
With surge voltage suppressor
(Non-polar type)
With light/surge voltage suppressor
(Non-polar type)
∗ For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit.
∗ For “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in the \"Z\" type.
∗ DOZ and YOZ are not available.
∗ For AC voltage valves there is no
“S” option. It is already built-in to
the rectifier circuit.
Light/Surge voltage suppressor
Note) When placing an order for body ported solenoid valve as a single unit, mounting
screw for manifold and gasket are not attached. Order them separately, if
necessary. (For details, refer to page 795.)
For AC ( Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
50 60
SY 5 1 20 5 L 01
∗ SY9000 has no bracket.
Nil: Without bracket
F1: With foot bracket
2 position
single only
F2: With side bracket
Bracket
Manual override
Note) AC-type models that are CE/UKCA-compliant
have DIN terminals only.
—
Main valve fluoro rubber (Refer to page 942.)
Nil
X90
X701 4-position dual 3-port valve (Refer to page 942-1.)
X20 Body ported external pilot (Refer to page 942.)
Made to Order
Nil —
Q CE/UKCA-compliant
CE/UKCA-compliant
SY3000/5000/7000/9000 Series
5 Port Solenoid Valve
Body Ported/Single Unit
How to Order
3 SY3000
5 SY5000
7
9
SY7000
SY9000
Series
Symbol Port size
M5 x 0.8 SY3000
Applicable series
SY5000
SY9000
M5
01
02 SY7000
02
03
1 4
1 4
1 8
3 8
Thread piping
One-touch fitting (Metric size)
A, B port size
Symbol Port size Applicable series
SY3000
SY5000
SY7000
SY9000
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
C8 One-touch fitting for ø8
C8 One-touch fitting for ø8
One-touch fitting for ø10
One-touch fitting for ø8
One-touch fitting for ø10
One-touch fitting for ø12
C10
C8
C10
C12
One-touch fitting (Inch size)
Symbol Port size Applicable series
SY3000
SY5000
SY7000
SY9000
N3 One-touch fitting for ø
N7 One-touch fitting for ø
N3 One-touch fitting for ø
N7 One-touch fitting for ø
N9 One-touch fitting for ø
N9 One-touch fitting for ø
One-touch fitting for ø
One-touch fitting for ø
One-touch fitting for ø
N11
N9
N11
5 32\"
1 4\"
5 32\"
1 4\"
5 16\"
5 16\"
3 8\"
5 16\"
3 8\"
∗ Except for M5
Rc
NPT
Nil
N
T NPTF
F G
Thread type
Nil: Non-locking
push type
D: Push-turn locking
slotted type
E: Push-turn locking
lever type
[Option]
G: Lead wire
length 300 mm
L: With lead wire
(Length 300 mm)
M: With lead wire
(Length 300 mm)
MN: Without lead
wire
D, Y: With connector
H: Lead wire
length 600 mm
LN: Without lead
wire
LO: Without
connector
MO: Without
connector
DO, YO: Without
connector
WO: Without
connector cable
Wfi: With connector
cable
CE/UKCAcompliant
DC
AC
CE/UKCAcompliant
A 732
Body Ported SY3000/5000/7000/9000 Series
Made to Order
(For details, refer to pages 934 to 947.)
Specifications
Note) Based on dynamic performance test, JIS B 8419: 2010. (Coil temperature: 20°C, at rated voltage)
SY3000
SY5000
SY7000
Series
Fluid
Ambient and fluid temperature (°C)
Internal pilot
Operating pressure
range (MPa)
Max. operating
frequency (Hz)
Manual override (Manual operation)
Pilot exhaust method
Lubrication
Mounting orientation
Impact/Vibration resistance (m/s2
) Note)
Enclosure
SY3000 SY5000 SY7000
Air
0.1 to 0.7
0.2 to 0.7
–10 to 50 (No freezing)
Non-locking push type,
Push-turn locking slotted type, Push-turn locking lever type
∗ Based on IEC60529
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles
to the main valve and armature in both energized and de-energized states every once
for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.
∗ DIN terminal and M8 connector with power saving circuit are not available.
∗ For details, refer to page 955.
10
3
5
3
Common exhaust type for main and pilot valve
Not required
Unrestricted
150/30
Dust proof (∗ DIN terminal and M8 connector: IP65)
5
3
SY9000
5
3
2 position single
2 position double
3 position
2 position single, double
3 position
0.15 to 0.7
Electrical entry
Coil rated
voltage (V)
Allowable voltage fluctuation
Power
consumption (W)
Apparent power
(VA) ∗
Surge voltage suppressor
Indicator light
DC
DC
AC Hz 50 60
AC
100 V
200 V
110 V
[115 V]
220 V
[230 V]
Grommet (G), (H)
L plug connector (L)
M plug connector (M)
G, H, L, M, W
24, 12, 6, 5, 3
D, Y
24, 12
0.78 (With indicator light: 0.81)
100, 110, 200, 220
±10% of rated voltage ∗
0.1 (With indicator light only) ∗
[Starting 0.4, Holding 0.1]
0.35 (With indicator light: 0.4 DIN terminal with indicator light: 0.45)
1.30 (With indicator light: 1.34)
[1.42 (With indicator light: 1.46)]
1.18 (With indicator light: 1.22)
0.86 (With indicator light: 0.89)
[0.94 (With indicator light: 0.97)]
0.78 (With indicator light: 0.87)
1.27 (With indicator light: 1.46)
[1.39 (With indicator light: 1.60)]
1.15 (With indicator light: 1.30)
0.86 (With indicator light: 0.97)
[0.94 (With indicator light: 1.07)]
Diode (Varistor is for DIN terminal and Non-polar type.)
LED (AC of DIN connector is neon light.)
Type of
actuation Without light/surge
voltage suppressor
12 or less
With light/surge voltage suppressor
Response time (ms) (at the pressure of 0.5 MPa)
Type S, Z Type R, U
2 position single 15 or less 12 or less
2 position double 10 or less 13 or less 10 or less
3 position 15 or less 20 or less 16 or less
Type of
actuation Without light/surge
voltage suppressor
19 or less
With light/surge voltage suppressor
Response time (ms) (at the pressure of 0.5 MPa)
Type S, Z Type R, U
2 position single 26 or less 19 or less
2 position double 18 or less 22 or less 18 or less
3 position 32 or less 38 or less 32 or less
Type of
actuation Without light/surge
voltage suppressor
31 or less
With light/surge voltage suppressor
Response time (ms) (at the pressure of 0.5 MPa)
Type S, Z Type R, U
2 position single 38 or less 33 or less
2 position double 27 or less 30 or less 28 or less
3 position 50 or less 56 or less 50 or less
SY9000
Type of
actuation Without light/surge
voltage suppressor
35 or less
With light/surge voltage suppressor
Response time (ms) (at the pressure of 0.5 MPa)
Type S, Z Type R, U
2 position single 41 or less 35 or less
2 position double 35 or less 41 or less 35 or less
3 position 62 or less 64 or less 62 or less
Standard
With power saving
circuit
DIN terminal (D), (Y)
M8 connector (W)
Solenoid Specifications
Response Time
733
SY3000/5000/7000/9000 Series
Valve
model
Type of
actuation
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
2 position
3 position
2 position
3 position
2 position
3 position
1, 5, 3
(P, EA, EB)
M5 x 0.8
4, 2
(A, B)
M5 x 0.8
1fi4/2 (PfiA/B) 4/2fi5/3 (A/BfiEA/EB) GroCvb mmet C (kdm3/
(s·bar)) Cvb C (kdm3/
(s·bar) )
L/M
plug
connector
51 53
68 74
71 76
60 63
78 83
81 86
56 59
74 79
77 82
Port size Flow rate characteristics Weight (g)
SY3fi20
-fi-M5
SY3fi20
-fi-C4
SY3fi20
-fi-C6
Note) [ ]: denotes normal position.
C4
Onetouch fitting
for ø4
C6
Onetouch fitting
for ø6
SY3000 series
Valve
model
Type of
actuation
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
2 position
3 position
2 position
3 position
2 position
3 position
1, 5, 3
(P, EA, EB)
1 (P)
Port
5, 3
(EA, EB)
port
4, 2
(A, B)
1fi4/2 (PfiA/B) 4/2fi5/3 (A/BfiEA/EB) GroCvb mmet C (dm3/
(s·bar) ) Cvb C (dm3/
(s·bar) )
L/M
plug
connector
101 104
120 125
128 133
107 110
126 132
134 140
103 105
122 127
130 135
Port size Flow rate characteristics Weight (g)
SY7fi20
-fi-02
SY7fi20
-fi-C8
SY7fi20
-fi-C10
Note) [ ]: denotes normal position.
C8
Onetouch fitting
for ø8
C10
Onetouch fitting
for ø10 177
DIN
terminal
125
167
175
131
174
182
126
169
SY7000 series
1 4
1 8
1 4
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
2 position
3 position
2 position
3 position
2 position
3 position
70 72
88 93
93 98
94 96
111 117
117 122
88 91
106 111
111 116
SY5fi20
-fi-01
SY5fi20
-fi-C4
SY5fi20
-fi-C6
Note) [ ]: denotes normal position.
C4
Onetouch fitting
for ø4
C6
Onetouch fitting
for ø6 158
93
135
140
117
159
164
112
153
Single
Double
Closed
center
Exhaust
center
Pressure
center
2 position
3 position
80 82
98 103
103 108
SY5fi20
-fi-C8
C8
Onetouch fitting
for ø8 150
103
145
124
76
101
106
100
125
130
95
119
116
86
111
SY5000 series
1 8
1 8
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
2 position
3 position
2 position
3 position
2 position
3 position
241 244
260 266
284 290
236 239
255 261
279 285
293 296
312 318
336 342
SY9fi20
-fi-02
SY9fi20
-fi-03
SY9fi20
-fi-C8
Note) [ ]: denotes normal position.
C8
Onetouch fitting
for ø8 384
265
308
332
260
303
327
317
360
Single
Double
Closed
center
Exhaust
center
Pressure
center
2 position
3 position
279 282
298 304
322 328
SY9fi20
-fi-C10
C10
Onetouch fitting
for ø10 370
303
346
Single
Double
Closed
center
Exhaust
center
Pressure
center
2 position
3 position
265 268
284 290
308 314
SY9fi20
-fi-C12
C12
Onetouch fitting
for ø12 356 322
289
332
272
298
SY9000 series
1 4
3 8
1 4
Flow Rate Characteristics/Weight
0.61
0.47
0.18
0.13
(0.12)
0.44
0.42
0.45
0.41
(0.37)
0.16
0.13
0.64
0.47
(0.44)
0.48 0.46 0.13 0.47 0.43 0.13
0.50
(0.41) 0.13 0.48
(0.35) 0.43 0.15
(0.11) 0.47
0.72
0.63
0.17
0.11
(0.11)
0.29
0.35
0.34
0.34
(0.37)
0.18
0.16
0.64
0.42
(0.41)
0.59 0.28 0.15 0.59 0.30 0.15
0.76
(0.46) 0.15 0.42
(0.34) 0.29 0.21
(0.12) 0.59
0.76
0.65
0.17
0.17
(0.11)
0.30
0.32
0.39
0.31
(0.36)
0.19
0.16
0.65
0.64
(0.42)
0.76 0.55 0.24 0.60 0.33 0.16
0.77
(0.49) 0.16 0.34
(0.43) 0.34 0.21
(0.15) 0.61
1.9
1.5
0.61
0.59
(0.40)
0.35
0.44
0.39
0.32
(0.43)
0.49
0.41
2.4
2.5
(1.5)
1.7 0.43 0.45 1.8 0.35 0.46
2.2
(0.91) 0.46 0.46
(0.58) 0.38 0.61
(0.28) 1.8
0.75
0.75
0.30
0.30
(0.27)
0.43
0.36
0.64
0.64
(0.53)
0.20
0.19
0.85
0.84
(0.84)
1.5
1.3
0.52
0.44
(0.35)
0.33
0.33
0.37
0.35
(0.37)
0.33
0.33
2.0
1.8
(1.4)
0.74 0.40 0.19 0.84 0.57 0.28
0.78
(0.71) 0.27 0.44
(0.37) 0.57 0.21
(0.18) 0.84
1.9
1.4
0.57
0.52
(0.43)
0.21
0.38
0.29
0.37
(0.41)
0.45
0.39
2.3
2.0
(1.5)
1.6 0.29 0.39 1.7 0.38 0.46
2.2
(1.6) 0.50 0.32
(0.44) 0.41 0.56
(0.44) 1.8
1.3 0.31 0.33 1.6 0.32 0.39
1.7
(0.80) 0.44 0.31
(0.47) 0.33 0.42
(0.23) 1.7
7.0
6.4
2.0
2.2
(0.91)
0.33
0.36
0.35
0.41
(0.27)
1.7
1.6
7.6
8.3
(4.1)
6.7 0.37 1.7 6.4 0.34 1.6
8.0
(3.2) 1.4 0.27
(0.34) 0.22 1.8
(0.76) 6.5
8.0
8.0
2.0
2.2
(2.3)
0.29
0.33
0.33
0.34
(0.40)
1.9
1.9
8.0
8.7
(8.3)
7.9 0.33 1.9 6.6 0.27 1.6
8.9
(3.3) 1.5 0.34
(0.40) 0.25 2.2
(0.82) 6.5
4.3
4.3
1.7
1.9
(0.86)
0.28
0.3
0.32
0.36
(0.29)
0.96
0.99
7.1
7.4
(3.8)
4.3 0.31 0.99 6.1 0.28 1.4
4.4
(3.2) 0.53 0.35
(0.26) 0.41 1.0
(0.71) 2.1
6.1
5.8
1.9
2.0
(0.93)
0.28
0.25
0.33
0.33
(0.27)
1.4
1.3
7.9
8.4
(4.1)
5.9 0.30 1.4 6.5 0.26 1.5
6.3
(3.2) 1.5 0.29
(0.29) 0.25 1.5
(0.72) 6.4
7.0
6.6
2.2
2.6
(1.0)
0.25
0.23
0.41
0.48
(0.32)
1.6
1.4
8.6
9.4
(4.5)
6.9 0.24 1.6 7.0 0.33 1.7
7.4
(3.2) 1.5 0.25
(0.34) 0.23 1.7
(0.74) 6.6
4.1
2.5
3.2
2.4
3.8
2.5
0.81
0.82
(0.54)
0.82
0.70
(0.56)
0.82
0.70
(0.56)
0.23
0.39
0.26
0.25
0.26
0.25
0.33
0.35
(0.38)
0.37
0.42
(0.46)
0.34
0.38
(0.38)
0.93
0.65
0.77
0.57
0.86
0.59
3.3
3.4
(2.1)
2.9 0.31 0.70 2.4 0.38 0.63
4.3
(2.4) 0.58 0.23
(0.32) 0.39 0.97
(0.61) 2.2
2.6 0.24 0.63 2.4 0.31 0.62
3.3
(2.4) 0.60 0.28
(0.22) 0.34 0.78
(0.57) 2.2
2.8 0.27 0.67 2.4 0.21 0.59
3.8
(2.4) 0.61 0.25
(0.31) 0.38 0.89
(0.61) 2.3
3.2
2.6
(1.9)
3.2
2.7
(2.0)
W
M8
connector
108
133
141
114
140
148
109
135
143
W
M8
connector
57
82
84
67
91
94
63
87
90
350
248
274
298
243
269
293
300
326
336
286
312
Valve
model
Type of
actuation 1, 5, 3
(P, EA, EB)
4, 2
(A, B)
1fi4/2 (PfiA/B) 4/2fi5/3 (A/BfiEA/EB) GroCvb mmet C (dm3/
(s·bar) ) Cvb C (dm3/
(s·bar) )
L/M
plug
connector
Port size Flow rate characteristics
DIN
terminal
W
M8
connector
Valve
model
Type of
actuation 1, 5, 3
(P, EA, EB)
4, 2
(A, B)
1fi4/2 (PfiA/B) 4/2fi5/3 (A/BfiEA/EB) GroCvb mmet C (dm3/
(s·bar) ) Cvb C (dm3/
(s·bar) )
L/M
plug
connector
Port size Flow rate characteristics
DIN
terminal
W
M8
connector
Weight (g) Weight (g)
734
(EA)5 1(P)3(EB)
2(B)(A)4
(EA)5 1(P)3(EB)
2(B)(A)4
(EA)5 1(P)3(EB)
2(B)(A)4
(EA)5 1(P)3(EB)
2(B)(A)4
(A)4 2(B)
1
(P) (EA)5 3(EB)
(EA)5 1
(P)
3(EB)
2(B)(A)4
(EA)5 1
(P)
3(EB)
2(B)
(SY9000)
(SY9000)
(SY9000)
(A)4
(EA)5 1
(P)
3(EB)
2(B)(A)4
Symbol
2 position single
Symbol
2 position double
Symbol
3 position closed center
3 position exhaust center
3 position pressure center
(A) (B)
(A) (B)
(P)
1
4 2
(EB)
3 (EA)
5
(P)
1
4 2
(EB)
3 (EA)
5
(P)
1
(A) (B)
(EB)
3
(EA)
5
4 2
A
B
q e
y w u q r
y wr u
t
t
y w u q r
t
Body Ported SY3000/5000/7000/9000 Series
SY series 2 position single
2 position double
3 position closed center / exhaust center / pressure center
Construction
(This figure shows a closed center type.)
Component Parts
Replacement Parts
Bracket Assembly No.
How to Change Port Block Assembly
For SY5000
Caution
Mounting screw tightening torques
SY3000 (M2): 0.12 N·m
SY 000 (M3): 0.6 N·m
SY9000 (M4): 1.4 N·m
5
7
No.
2
3
1
Description
Resin
Resin
Material
Aluminum die-casted
(SY3000: Zinc die-casted)
4 Resin –
–
Note
White
White
(SY9000: Gray)
White
Adapter plate
Body
End plate
Piston
5 Spool valve assembly Aluminum, H-NBR
No.
7
6
Description Part no.
Refer to “How to Order Pilot Valve Assembly” on page 948.
M5 port block assembly Refer to “How to Order Port Block Assembly” on page 948.
Pilot valve assembly
Description
Bracket (For F2)
Bracket (For F1)
Part no.
SX 000-16-2A (with mounting screw) 3
5
7
SX 000-16-1A (with mounting screw) 3
5
7
∗ SY9000 has no bracket.
∗ Refer to “How to Order
Port Block Assembly” on
page 948 for part no.
Mounting screw
(Threaded type)
(Cassette type)
M5 port block Assembly
Fitting
Assembly
If using body port type, both A and B port sizes can be changed by replacing
the port block assembly mounted on the body. When changing this block
assembly, the correct screw torque must be achieved to avoid possible air
leakage. M5 port block Assembly
735 B
A
B
P
EA EB
(Light/surge voltage suppressor)
22.5
(Lead wire length)
21.4
Manual override
8.6 2 x ø2.2
(For manifold mounting)
10.2
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32\"
ø6, ø1/4\"
16.9 18.5 10 0.8
M5 x 0.8
For manifold gasket positioning (P, EA, EB port)
2 x ø1.5 die-cast hole 19
(15)
(27)
(For mounting)
2 x ø3.2
4
9.5 2 x M3 x 0.5 depth 4
(For mounting bracket)
25
28.5 [35.5]
(35.5) (32)
44.7
66.9 [69.1]
G: Approx. 300
H: Approx. 600
13.1
(35)
+-
2
C6: 33.6 N7: 37.4 (3.2) 1.2 11.6
1724
(For mounting)
2 x ø3.2
-+ 25
28.5 [35.5]
13.1
31
38
69.4 [71.6]
C6:33.6 (3.2) N7:37.4 7.5
16.9 18.5 23.5
22.5
33
M8 x 1
68.5
22.5
75.9
15.5
16.9
C6: 33.6
N7: 37.4 (3.2)
18.5
25 28.5 [35.5]
A, B port
M5 x 0.8
39.6 [46.6]
(Lead wire length)
Approx.
300
67 [69.2] 62
22.5
16.9
C6: 33.6
N7: 37.4 (3.2)
18.5
28.5 [35.5]
13.1
Approx. 300 (Lead wire length)
76.8 [79]
22.5
16.9
18.5
C6: 33.6
N7: 37.4 (3.2)
Note) Refer to page 961 for
dimensions of connector types.
SY3000/5000/7000/9000 Series
L plug connector (L):
SY3120-fiLfifi- (-F )
Dimensions: SY3000 Series [ ]: AC
2 position single
Grommet (G), (H): SY3120-fi fifi- (-F2) G
H
C4, N3
C6, N7
Foot bracket
SY3120-fi fifi- -F1 G
H C4, N3
C6, N7
SY3120-fi fifi-M5(-F2) G
H
1
2 1
2 C4, N3
C6, N7
M plug connector (M):
SY3120-fiMfifi- (-F ) C4, N3
C6, N7
M8 connector (WO):
SY3120-fiWOfifi- (-F ) C4, N3
C6, N7 1
2
736
A
B
21.4
8.6
(Lead wire length)
Manual override
(For manifold mounting)
2 x ø2.2
A, B port
Applicable tubing O.D.: ø4, ø5/32\"
: ø6, ø1/4\"
One-touch fitting
10.2
44.4
88.8 [93.2]
G: Approx. 300
H: Approx. 600
4
9.5
2 x M3 x 0.5 depth 4
(For mounting bracket)
P
EA EB
19 M5 x 0.8
(P, EA, EB port)
2 x ø1.5 die-cast hole
(For manifold gasket positioning)
(15) 10 0.8
2
16.9 23.5
(A, B port)
M5 x 0.8
25
28.5 [35.5]
(Light/surge voltage suppressor)
16.9
(For mounting)
2 x ø3.2
13.125 28.5 [35.5] (32) (35.5)
+-
(27)
(35)
C6:33.6 N7:37.4 (3.2)
28.5 [35.5]
13.1 Approx. 300 (Lead wire length) 108.6 [113]
16.9
C6:33.6
N7:37.4 (3.2)
39.6 [46.6] Approx. 300
(Lead wire length) 89 [93.4] 79
16.9
C6:33.6
N7:37.4 (3.2)
33
15.5 M8 x 1 106.8 92
16.9
C6:33.6
N7:37.4 (3.2)
Note) Refer to page 961 for
dimensions of connector types.
Body Ported SY3000/5000/7000/9000 Series
Dimensions: SY3000 Series
2 position double
[ ]: AC
Grommet (G), (H): SY3220-fi fifi- (-F2) G
H
C4, N3
C6, N7 SY3220-fi fifi-M5(-F2) G
H
L plug connector (L):
SY3220-fiLfifi- (-F2) C4, N3
C6, N7
M plug connector (M):
SY3220-fiMfifi- (-F2) C4, N3
C6, N7
M8 connector (WO):
SY3220-WOfifi- (-F ) C4, N3
C6, N7 1
2
737
SY3 20-fi fifi-M5(-F2) G
H
3
4
5
(Light/surge voltage suppressor)
+- 13.1
A
B
(Lead wire length)
8.6
21.4
Manual override
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32\"
: ø6, ø1/4\"
(For manifold mounting)
2 x ø2.2
10.2
22.2
44.4 [46.6]
97.3 [101.7]
G: Approx. 300
H: Approx. 600
30.7
9.5
2 x M3 x 0.5 depth 4
(For mounting bracket)
4
28.5 [35.5]
25 16.9 23.5
(A, B port)
M5 x 0.8
P
EA
(P, EA, EB port)
M5 x 0.8 For manifold gasket positioning
2 x ø1.5 die-cast hole 19
(15) 10
20.8 16.9
(For mounting)
2 x ø3.2
(35.5) (32) 25 28.5 [35.5]
(27)
(35)
C6:33.6 N7:37.4 (3.2)
28.5 [35.5]
13.1
Approx. 300 (Lead wire length) 54.3 [56.5] 117.1 [121.5]
(3.2) C6: 33.6
N7: 37.4
16.9
39.6 [46.6] Approx. 300
(Lead wire length) 44.5 [46.7] 97.5 [101.9]39.5 48
(3.2)
16.9
C6: 33.6
N7: 37.4
M8 x 1
33
15.5
46 54.5
53.4
115.3
16.9
C6: 33.6
N7: 37.4 (3.2)
Note) Refer to page 961 for
dimensions of connector types.
SY3000/5000/7000/9000 Series
[ ]: AC
3 position closed center / exhaust center / pressure center
Grommet (G), (H): SY3 20-fi fifi- (-F2) G
H C4, N3
C6, N7
3
4
5
L plug connector (L):
SY3 20-fiLfifi- (-F2) 3
4
5
M plug connector (M):
SY3 20-fiMfifi- (-F2) C4, N3
C6, N7
C4, N3
C6, N7
M8 connector (WO):
SY3 20-fiWOfifi- (-F2) C4, N3
C6, N7
3
4
5
3
4
5
Dimensions: SY3000 Series
738
EA P EB
For manifold gasket positioning
2 x ø2.2 die-cast hole
(P, EA, EB port)
1/8 27.2 0.8 1.6 15 (20)
B A
14.5
36
11.6
(Lead wire length)
Manual override
(For manifold mounting)
2 x ø3.2
A, B port
Applicable tubing O.D.: ø4, ø5/32\"
ø6, ø1/4\"
ø8, ø5/16\"
One-touch fitting
63.7
H: Approx. 600 85.9 [88.1] G: Approx. 300
+ 16.6 2229
(For mounting)
2 x ø3.2
12.7
47
38
1.2
(4.9) 40.4 10.5
28.1 [35.1]
88.6 [90.8]
32.3
40.4 (4.9)
12.7 (Lead wire length)
20.5
23
28.1 [35.1] Approx. 300 95.8 [98]
32.3
20.5
23
40.4 (4.9)
(Lead wire length)
39.2 [46.2] Approx. 300 81 86 [88.2]
- +
(Light/surge voltage suppressor) 12.7
22.6
16.7
2 x M3 x 0.5 depth 4
(For mounting bracket)
(37)
32.3
23 20.5
(For
mounting)
2 x ø3.2
40.4 (4.9)
28.1 [35.1] (36.7) (40.2)
(45)
(A, B port)
1/8
20.5 2332.5
16.2
28.1 [35.1]
M8 x 1
32.3
(4.9)
32.6
15.1
94.9 87.5
40.4
23
20.5
104.9 Max. 10
65
60.9
53.4
42.1
27
(4.9)
23
20.5
105.8
32.3
Applicable cable O.D.
ø3.5 to ø7
Pg7
40.4
Note) Refer to page 961 for
dimensions of connector types.
Body Ported SY3000/5000/7000/9000 Series
[ ]: AC
SY5120-fi fifi- fi(-F )
Dimensions: SY5000 Series
2 position single
Grommet (G), (H): SY5120-fi fifi- fi(-F2) G
H
C4, N3
C6, N7
C8, N9
Foot bracket
SY5120-fi fifi- fi-F1 G
H
C4, N3
C6, N7
C8, N9
SY5120-fi fifi-01fi(-F ) G
H 1
2
1
2
M plug connector (M):
SY5120-fiMfifi- fi(-F )
DIN terminal (D, Y):
C4, N3
C6, N7
C8, N9
SY5120-fiWOfifi- fi(-F ) 1
2
M8 connector (WO):
C4, N3
C6, N7
C8, N9
1
2
C4, N3
C6, N7
C8, N9
L plug connector (L):
SY5120-fiLfifi- fi(-F ) 1
2
C4, N3
C6, N7
C8, N9
D
Y
739
14.5
36
11.6
107.2 [111.6] G: Approx. 300
H: Approx. 600
Manual override
(For manifold mounting)
2 x ø3.2
One-touch fitting
(A, B port)
Applicable tubing O.D. : ø4, ø5/32\"
: ø6, ø1/4\"
: ø8, ø5/16\"
B A
(Lead wire length) 62.8
20.5
40.4
127 [131.4] Approx. 300
12.7
28.1 [35.1] (Lead wire length)
(4.9)
39.2 [46.2] Approx. 300
(Lead wire length) 97.4 107.4 [111.8]
40.4
20.5
(4.9)
- +
(37)
28.1 [35.1] (36.7) (40.2) 40.4 20.512.7
(Light/surge voltage suppressor) (For mounting)
2 x ø3.2
(45)
(4.9)
27.2
0.8 15 (20)
For manifold gasket positioning
2 x ø2.2 die-cast hole (P, EA, EB port)
1/8
EA P EB
1.6
22.6
16.7
2 x M3 x 0.5 depth 4
(For mounting bracket)
28.1 [35.1] 20.532.5
1/8
(A, B port)
16.2
M8 x 1
20.5
40.4 (4.9) 110.4 125.2
32.6
15.1
20.5
40.4
27 Max. 10 65.4 145.2
53.4
42.1
(4.9)
147
Applicable cable O.D.
ø3.5 to ø7
Pg7
60.9
Note) Refer to page 961 for
dimensions of connector types.
SY3000/5000/7000/9000 Series
2 position double
Grommet (G), (H): SY5220-fi fifi- fi(-F2) G
H
C4, N3
C6, N7
C8, N9
SY5220-fi fifi-01fi(-F2) G
H
L plug connector (L):
SY5220-fiLfifi- fi(-F2) C4, N3
C6, N7
C8, N9
M plug connector (M):
SY5220-fiMfifi- fi(-F2) C4, N3
C6, N7
C8, N9
DIN terminal (D, Y):
SY5220-fi fifi- fi(-F2) C4, N3
C6, N7
C8, N9
M8 connector (WO):
SY5220-fiWOfifi- fi(-F2) C4, N3
C6, N7
C8, N9
Dimensions: SY5000 Series
D
Y
[ ]: AC
740
14.5
36
G: Approx. 300
H: Approx. 600
31.4 44
53.6 [55.8]
119.8 [124.2]
(Lead wire length)
Manual override
(For manifold mounting)
2 x ø3.2
One-touch fitting
(A, B port)
Applicable tubing O.D.:
ø4, ø5/32\"
ø6, ø1/4\"
ø8, ø5/16\" 11.6
(4.9)
12.7
28.1 [35.1]
139.6 [144] 63.5 [65.7] Approx. 300 (Lead wire length)
20.5
40.4
22.6
16.7
2 x M3 x 0.5 depth 4
(For mounting bracket)
28.1 [35.1] 20.532.5
1/8
16.2 (A, B port)
27.2
(37)
12.7 28.1 [35.1] (36.7) (40.2) 20.540.4 15 0.8 (20)
(Light/surge voltage suppressor)
For manifold gasket positioning
2 x ø2.2 die-cast hole
(P, EA, EB port)
1/8
(For mounting)
2 x ø3.2 (4.9)
1.6
(45)
+-
(4.9)
39.2 [46.2] Approx. 300
(Lead wire length) 48.7 53.7 [55.9] 120 [124.4]
20.5
40.4
61.3
20.5
40.4 (4.9)
M8 x 1
137.8
55.2 62.6 67.8
32.6 15.1
40.4
20.5
27
157.8 Max. 10
72.6 45.3 32.7 159.6
60.9
53.4
42.1
73.5
(4.9)
Pg7
Applicable cable O.D.
ø3.5 to ø7
Note) Refer to page 961 for
dimensions of connector types.
Body Ported SY3000/5000/7000/9000 Series
3 position closed center / exhaust center / pressure center
Grommet (G), (H): SY5 20-fi fifi- fi(-F2) G
H
Dimensions: SY5000 Series
C4, N3
C6, N7
C8, N9
3
4
5
L plug connector (L):
SY5 20-fiLfifi- fi(-F2) 3
4
5
C4, N3
C6, N7
C8, N9
M plug connector (M):
SY5 20-fiMfifi- fi(-F2) 3
4
5
C4, N3
C6, N7
C8, N9
DIN terminal (D, Y):
SY5 20-fi fifi- fi(-F2) 3
4
5
C4, N3
C6, N7
C8, N9
M8 connector (WO):
SY5 20-fiWOfifi- fi(-F2) 3
4
5
C4, N3
C6, N7
C8, N9
D
Y
[ ]: AC
SY5 20-fi fifi-01fi(-F2) 3
4
5
G
H
741
SY7120-fi fifi-02fi(-F2) G
H
36
2 18
(23.9)
For manifold gasket positioning
2 x ø2.2 die-cast hole
EA P EB
(EA, EB port)
1/8
(P port)
1/4 0.9
24.5 2840
20
39.4
A, B port
1/4
31.5 [38.5]
Manual override 19
42
13.6
(For manifold mounting)
2 x ø4.2
B
A
(Lead wire length)
One-touch fitting
(A, B port)
Applicable tubing O.D. : ø8, ø5/16\"
: ø10, ø3/8\"
G: Approx. 300
H: Approx. 600 100.1 [102.3]
77.9
20
7
2 x M4 x 0.7 depth 6.5
(For mounting bracket)
(Light/surge voltage suppressor)
24.5 28
(52)
(66) (For mounting)
2 x ø4.2
+- 16.1 31.5 [38.5] (42.5) (49.5) 47.6
39.4
(5.5) 1.2
31.5 [38.5]
47.6 12.5101.8 [104]
(5.5)
19.8 2838
(For mounting)
2 x ø4.2
16.1
+- 46
57
M8 x1
(5.5) 101.7
19
36
109.1
39.4
47.6
28
24.5
66
58.5
47.2
(5.5) 28
24.5
32.1
119.1 120 39.4
47.6
Pg7
79.2
Max. 10
Applicable cable O.D.
ø3.5 to ø7
24.5
28
47.6
39.4
Approx. 300 (Lead wire length) 110 [112.2]
16.1
31.5 [38.5]
(5.5)
24.5
28
47.6
39.4100.2 [102.4] 95.2
Approx. 300
(Lead wire length)
42.6 [49.6]
(5.5)
Note) Refer to page 961 for
dimensions of connector types.
SY3000/5000/7000/9000 Series
Dimensions: SY7000 Series
2 position single
Grommet (G), (H): SY7120-fi fifi- fi(-F2) G
H C8, N9
C10, N11 SY7120-fi fi- fi-F1 G
H C8, N9
C10, N11
L plug connector (L):
SY7120-fiLfifi- fi(-F ) C8, N9
C10, N11 1
2
M plug connector (M):
SY7120-fiMfifi- fi(-F ) C8, N9
C10, N11 1
2
DIN terminal (D, Y):
SY7120-fi fifi- fi(-F ) C8, N9
C10, N11 1
2
M8 connector (WO):
SY7120-fiWOfifi- fi(-F ) C8, N9
C10, N11 1
2 D
Y
[ ]: AC
742
For manifold gasket positioning
2 x ø2.2 die-cast hole
EA P EB
(EA, EB port)
1/8
(P port)
1/4
36
18 (23.9)
2
0.9
20 (A, B port)
1/4
31.5 [38.5] 24.540
Approx. 300 (Lead wire length) 141.2 [145.6]
24.5
47.6
16.1
31.5 [38.5]
(5.5)
121.6 [126] 111.6
42.6 [49.6] Approx. 300
(Lead wire length)
24.5
47.6 (5.5)
(Light/surge voltage suppressor)
+- 16.1
19
42
Manual override
(For manifold mounting)
2 x ø4.2
(Lead wire length)
B
A
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø8, ø5/16\"
ø10, ø3/8\" G: Approx. 300
H: Approx. 600
77
121.4 [125.8]
13.6
(52)
(66) (For mounting)
2 x ø4.2
31.5 [38.5] 24.5(42.5) (49.5) 47.6 (5.5)
20
7
(For mounting bracket)
2 x M4 x 0.7 depth 6.5
M8 x 1
(5.5)
24.5
36
18.5
124.6 139.4
47.6
66
58.5
47.2
(5.5)
24.5
159.4 161.2 79.6
Pg7
47.6
Max. 10
32.1
Applicable cable O.D.
ø3.5 to ø7
Note) Refer to page 961 for
dimensions of connector types.
Body Ported SY3000/5000/7000/9000 Series
Dimensions: SY7000 Series
2 position double
Grommet (G), (H): SY7220-fi fifi- fi(-F2) G
H C8, N9
C10, N11 SY7220-fi fifi-02fi(-F2) G
H
L plug connector (L):
SY7220-fiLfifi- fi(-F2) C8, N9
C10, N11
M plug connector (M):
SY7220-fiMfifi- fi(-F2) C8, N9
C10, N11
DIN terminal (D, Y):
SY7220-fi fifi- fi(-F2) C8, N9
C10, N11
M8 connector (WO):
SY7220-fiWOfifi- fi(-F2) C8, N9
C10, N11
D
Y
[ ]: AC
743
36
For manifold gasket positioning
2 x ø2.2 die-cast hole
(EA, EB port)
1/8
(P port)
1/4
EA P EB
2
18 0.9
(23.9)
20 (A, B port)
1/4
31.5 [38.5] 24.540
70.6 [72.8]
Approx. 300 (Lead wire length) 154.2 [158.6]
16.1
31.5 [38.5]
24.5
47.6 (5.5)
134.6 [139] 60.8 [63]
24.5
47.6
68.8
42.6 [49.6] Approx. 300
(Lead wire length) 55.8
(5.5)
20
7
19
42
13.6
G: Approx. 300
H: Approx. 600 134.4 [138.8]
60.7 [62.9]
38.5 51.5
Manual override
(For manifold mounting)
2 x ø4.2
(Lead wire length)
(A, B port)
Applicable tubing O.D. : ø8, ø5/16\"
: ø10, ø3/8\"
One-touch fitting
B
A
M8 x 1
(5.5)
24.5
75.3 69.7 62.3
152.4
36
18.5
47.6
66
58.5
47.2
(5.5) 24.5
172.4
79.7
52.8 39.8 174.2 80.6
32.1
Pg7
47.6
Max. 10
Applicable cable O.D.
ø3.5 to ø7
Note) Refer to page 961 for
dimensions of connector types.
16.1
(52)
(66)
(Light/surge voltage suppressor)
+- 31.5 [38.5] 24.5(42.5) (49.5) 47.6 (5.5)
(For mounting bracket)
2 x M4 x 0.7 depth 6.5
(For mounting)
2 x ø4.2
SY3000/5000/7000/9000 Series
3 position closed center / exhaust center / pressure center
Grommet (G), (H): SY7 20-fi fifi- fi(-F2) G
H C8, N9
C10, N11
3
4
5
L plug connector (L):
SY7 20-fiLfifi- fi(-F2) C8, N9
C10, N11
3
4
5
M plug connector (M):
SY7 20-fiMfifi- fi(-F2) C8, N9
C10, N11
3
4
5
DIN terminal (D, Y):
SY7 20-fi fifi- fi(-F2) C8, N9
C10, N11
3
4
5
M8 connector (WO):
SY7 20-fiWOfifi- fi(-F2) C8, N9
C10, N11
3
4
5
SY7 20-fi fifi-02fi(-F2) G
H
3
4
5
Dimensions: SY7000 Series
D
Y
[ ]: AC
744
(Light/surge voltage suppressor) 25.5
- +
5EA 1P 3EB
[1(P), 5(EA), 3(EB) port]
1/4 230.5 0.5
49.8
(For mounting)
2 x ø4.4
39.1 40.9 [47.9]
24.9
10
36.6
61 (5.5)
56.3
36.6
39.1
61 (5.5) 140.1 [142.3] Approx. 300 (Lead wire length)
25.5
40.9 [47.9]
(5.5)
130.3 [132.5] 125.3
52 [59] Approx. 300
(Lead wire length)
36.6
39.1
61
56.3
4A 2B
(Lead wire length)
(For manifold mounting)
3 x ø3.2
Manual
override
[4(A), 2(B) port]
Applicable tubing O.D.: ø8, ø5/16\"
ø10, ø3/8\"
ø12
One-touch fitting
G: Approx. 300
H: Approx. 600 130.2 [132.4]
6.5 56.3
18.4
33.6
64.2
108
55.9
67.2
74.7
Max. 10
150.1 149.2 109.3
40.9
61 (5.5)
36.6
56.3
Pg7
39.1
M8 x 1 45.4
27.9
139.2 131.8
56.3
61
39.1
36.6
(5.5)
Applicable cable O.D.
ø3.5 to ø7
Note) Refer to page 961 for
dimensions of connector types. 33.6
56.3
36.6
51.5
39.1
[4(A), 2(B) port]
3/8, 1/4
Body Ported SY3000/5000/7000/9000 Series
SY9120-fiLfifi- fi
SY9120-fi fifi- fi
Dimensions: SY9000 Series
2 position single
Grommet (G), (H): SY9120-fi fifi- fi
C8, N9
C10, N11
C12
C8, N9
C10, N11
C12
02
03
L plug connector (L):
SY9120-fiMfifi- fi C8, N9
C10, N11
C12
M plug connector (M):
SY9120-fi fifi- fi C8, N9
C10, N11
C12 C12
DIN terminal (D, Y):
SY9120-fiWOfifi- fi C8, N9
C10, N11
M8 connector (WO):
G
H G
H
[ ] AC
D
Y
745
25.5
(Light/surge voltage suppressor)
+- 40.9 [47.9]
(For mounting)
2 x ø4.4 24.9
10
36.6
61 (5.5)
36.6
61 (5.5) 167.6 [172] Approx. 300 (Lead wire length)
40.9 [47.9]
25.5
(Lead wire length)
36.6
61 (5.5)
52 [59] Approx. 300 138 148 [152.4]
G: Approx. 300
H: Approx. 600 147.8 [152.2]
4A 2B
(Lead wire length)
(For manifold mounting)
3 x ø3.2
Manual
override
Applicable tubing O.D.: ø8, ø5/16\"
: ø10, ø3/8\"
: ø12
One-touch fitting [4 (A), 2 (B) port] 33.6
64.2
6.5
103.4
18.4
5EA 1P 3EB
[1(P), 5(EA), 3(EB) port]
1/4
49.8 230.5 0.5
M8 x 1
165.8 151
45.4
27.9
61 (5.5) 36.6
74.7
67.2
55.9
185.8 187.6
61 (5.5)
36.6
106
Pg7Max. 10
40.9
Applicable cable O.D.
ø3.5 to ø7
Note) Refer to page 961 for
dimensions of connector types. 33.6
51.5
36.6
[4(A), 2(B) port]
3/8, 1/4
SY9220-fiLfifi- fi
SY9220-fi fifi- fi
Dimensions: SY9000 Series
2 position double
Grommet (G), (H): SY9220-fi fifi- fi C8, N9
C10, N11
C12
C8, N9
C10, N11
C12
02
03
L plug connector (L):
SY9220-fiMfifi- fi C8, N9
C10, N11
C12
M plug connector (M):
SY9220-fi fifi- fi C8, N9
C10, N11
C12
DIN terminal (D, Y):
SY9220-fiWOfifi- fi C8, N9
C10, N11
C12
M8 connector (WO):
G
H
G
H
[ ] : AC
D
Y
SY3000/5000/7000/9000 Series
746
Manual
override
G: Approx. 300
H: Approx. 600
(Lead wire length) 73.9 [76.1]
164.3 [168.7]
4A 2B
(For manifold mounting)
3 x ø3.2
Applicable tubing O.D. : ø8, ø5/16\"
: ø10, ø3/8\"
: ø12
One-touch fitting [4 (A), 2 (B) port]
6.5
18.4
33.6
64.2
51.7 68.2
(Light/surge voltage suppressor)
+-
25.5
(For mounting)
2 x ø4.4 24.9
40.9 [47.9] 10
36.6
61 (5.5)
5EA 1P 3EB
[1(P), 5(EA), 3(EB) port]
1/4
49.8 230.5 0.5
(Lead wire length)
25.5
40.9 [47.9]
83.8 [86]
184.1 [188.5] Approx. 300
36.6
61 (5.5)
85.5
52 [59] Approx. 300
(Lead wire length) 74 [76.2] 69 164.5 [168.9]
36.6
61 (5.5)
167.5
75.5 82.9
182.3
45.4
27.9
61 (5.5)
36.6
M8 x 1
55.9
67.2
74.7
Max. 10 202.3
93.8 92.9
204.1
(5.5)69.5 53
Pg7
61
36.6
40.9
Applicable cable O.D.
ø3.5 to ø7
Note) Refer to page 961 for
dimensions of connector types.
36.6
51.5
33.6
[4(A), 2(B) port]
3/8, 1/4
Body Ported SY3000/5000/7000/9000 Series
D SY9 20-fiLfifi- fi Y
C8, N9
C10, N11
C12
L plug connector (L): 3
4
5 SY9 20-fiMfifi- fi C8, N9
C10, N11
C12
M plug connector (M): 3
4
5 SY9 20-fi fifi- fi C8, N9
C10, N11
C12
DIN terminal (D, Y): 3
4
5 SY9 20-fiWOfifi- fi C8, N9
C10, N11
C12
M8 connector (WO): 3
4
5
3 position closed center / exhaust center / pressure center
Grommet (G), (H): SY9 20-fi fifi- fi C8, N9
C10, N11
C12
G
H
3
4
5
Dimensions: SY9000 Series
3
4
5
02 SY9 20-fi fifi 03 - fi G
H
[ ]: AC
747
(EA)5 1(P)3(EB)
2(B)(A)4
(EA)5 1(P)3(EB)
2(B)(A)4
(EA)5 1(P)3(EB)
2(B)(A)4
(EA)5 1(P)3(EB)
2(B)(A)4
(A)4 2(B)
1
(P) (EA)5 3(EB)
– +
- +
-+
+-
– +
+-
Grommet L plug connector
24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC 24, 12 VDC/
100, 110, 200, 220 VAC
M plug connector DIN terminal
24, 12, 6, 5, 3 VDC
M8 connector
1
2 position single
2
2 position double
3
3 position closed center
4
3 position exhaust center
5
3 position pressure center
SY 5 2 40 5 L
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC
For DC
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
∗ DC specifications of type D, Y, DO and
YO is only available with 12 and 24 VDC.
∗ For type Wfi, DC voltage is only available.
Note) AC-type models that are CE/UKCA-compliant
have DIN terminals only.
Type of actuation
Nil Internal pilot
R External pilot∗
Pilot type
Rated voltage
Electrical entry
∗ Power saving circuit is not available in the
case of D, Y, DO, YO or Wfi type.
∗ External pilot specifications
for SY3000 DIN terminal are
not available.
Nil Standard
T With power saving circuit (24, 12 VDC only)
Coil specifications
CE/UKCAcompliant
DC
AC
Note) For details about Symbol of
the 3 position type of SY9000
series, refer to page 751.
For AC ( Hz) 50 60
3 SY3000
5 SY5000
7 SY7000
9 SY9000
Series
Electrical entry for G, H, L, M, W
Nil Without light/surge voltage suppressor
S
Z
With surge voltage suppressor
With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
Electrical entry for D, Y
Nil Without light/surge voltage suppressor
S
Z
With surge voltage suppressor (Non-polar type)
With light/surge voltage suppressor (Non-polar type)
∗ For AC voltage valves there is no “S” option. It is
already built-in to the rectifier circuit.
∗ For “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in the \"Z\" type.
∗ DOZ and YOZ are not available.
∗ For AC voltage valves there is no “S”
option. It is already built-in to the rectifier
circuit.
Light/Surge voltage suppressor
Manual override
Nil —
X90 Main valve fluororubber
(Refer to page 942.)
X701 4-position dual 3-port valve
(Refer to page 942-1.)
Made to Order
Note)
AC-type models
that are CE/UKCAcompliant have
DIN terminals
only.
Nil —
Q CE/UKCA-compliant
CE/UKCA-compliant
1 8
Symbol Applicable series
Nil
01 SY3000
Port size
Without sub-plate
With sub-plate
With sub-plate
3 8
With sub-plate
02 SY5000
SY7000
SY7000
SY9000 03
1 2
With sub-plate 04 SY9000
1 4
Port size
Rc
NPT
Nil
N
T NPTF
F G
Thread type
Nil: Non-locking
push type
D: Push-turn locking
slotted type
E: Push-turn locking
lever type
SY3000/5000/7000/9000 Series
5 Port Solenoid Valve
Base Mounted/Single Unit Note) AC-type models that are CE/UKCAcompliant have DIN terminals only.
[Option]
How to Order
SY 5 2 40 5 L
G: Lead wire
length 300 mm
L: With lead wire
(Length 300 mm)
M: With lead wire
(Length 300 mm)
D, Y: With connector
H: Lead wire
length 600 mm
DO, YO: Without connector
WO: Without connector cable
– +
-+
-+
+-
LN: Without
lead wire
LO: Without
connector
MO: Without
connector
MN: Without lead
wire
Wfi: With connector cable
Note)
– +
+-
∗ LN, MN type: with 2 sockets.
∗ The DIN terminal of SY3000 series cannot be mounted on the standard sub-plate. For details, refer to page 958.
∗ “Y” type is a DIN terminal conforming to EN-175301-803C (former DIN43650C). For details, refer to page 957.
∗ For connector cable of M8 connector, refer to page 960.
∗ M8 connector conforming to IEC60947-5-2 standard is also available. Refer to page 941 for details.
∗ Refer to page 957 for the lead wire length of L and M plug connectors.
∗ Refer to page 958 for the connector assembly with cover for L and M plug connectors.
Note) Enter the cable length symbols in fi. Please be sure to fill in the blank referring to page 961.
Note) When ordering single unit of the base mounted type solenoid valve, the mounting screws and gaskets for the manifold are included.
fi
—
fi
—
fi
—
fi
fi
fi
—
A 748
Base Mounted SY3000/5000/7000/9000 Series
Made to Order
(For details, refer to pages 934 to 947.)
Specifications
SY3000
SY7000
SY5000
Response Time
SY9000
Series
Fluid
Internal pilot
Operating pressure
range (MPa)
External pilot
Operating pressure
range (MPa)
Ambient and fluid temperature (°C)
Max. operating
frequency (Hz)
Manual override
(Manual operation)
Pilot exhaust
method
Mounting orientation
Impact/Vibration resistance (m/s2
) Note)
Enclosure
SY3000 SY5000 SY7000
Air
0.1 to 0.7
0.2 to 0.7
–100 kPa to 0.7
0.25 to 0.7
0.25 to 0.7
0.25 to 0.7
–10 to 50 (No freezing.)
10
3
5
3
Pilot valve individual exhaust
Common exhaust type for main and pilot valve
Lubrication Not required
Unrestricted
150/30
Dust proof (∗ DIN terminal and M8 connector: IP65)
5
3
SY9000
5
3
2 position single
2 position double
3 position
Operating pressure range
Pilot
pressure
range
2 position double
2 position single
3 position
2 position single, double
3 position
Internal pilot
External pilot
Non-locking push type,
Push-turn locking slotted type, Push-turn locking lever type
∗ Based on IEC60529
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)
0.15 to 0.7
Type of
actuation Without light/surge
voltage suppressor
12 or less
With light/surge voltage suppressor
Response time (ms)
(at the pressure of 0.5 MPa)
Type S, Z Type R, U
2 position single 15 or less 12 or less
2 position double 10 or less 13 or less 10 or less
3 position 15 or less 20 or less 16 or less
Type of
actuation Without light/surge
voltage suppressor
19 or less
Response time (ms)
(at the pressure of 0.5 MPa)
Type S, Z Type R, U
2 position single 26 or less 19 or less
2 position double 18 or less 22 or less 18 or less
3 position 32 or less 38 or less 32 or less
Type of
actuation Without light/surge
voltage suppressor
31 or less
Response time (ms)
(at the pressure of 0.5 MPa)
Type S, Z Type R, U
2 position single 38 or less 33 or less
2 position double 27 or less 30 or less 28 or less
3 position 50 or less 56 or less 50 or less
Type of
actuation Without light/surge
voltage suppressor
35 or less
Response time (ms)
(at the pressure of 0.5 MPa)
Type S, Z Type R, U
2 position single 41 or less 35 or less
2 position double 35 or less 41 or less 35 or less
3 position 62 or less 64 or less 62 or less
Solenoid Specifications
Note) Based on dynamic performance test, JIS B
8419: 2010. (Coil temperature: 20°C, at
rated voltage)
With light/surge voltage suppressor
With light/surge voltage suppressor
With light/surge voltage suppressor
∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.
∗ DIN terminal and M8 connector with power saving circuit are not available.
∗ For details, refer to page 955.
Electrical entry
Coil rated
voltage (V)
Allowable voltage fluctuation
Power
consumption (W)
Apparent power
(VA) ∗
Surge voltage suppressor
Indicator light
DC
DC
AC Hz 50 60
AC
100 V
200 V
110 V
[115 V]
220 V
[230 V]
Grommet (G), (H)
L plug connector (L)
M plug connector (M)
G, H, L, M, W
24, 12, 6, 5, 3
D, Y
24, 12
0.78 (With indicator light: 0.81)
100, 110, 200, 220
±10% of rated voltage ∗
0.1 (With indicator light only) ∗
[Starting 0.4, Holding 0.1]
0.35 (With indicator light: 0.4 DIN terminal with indicator light: 0.45)
1.30 (With indicator light: 1.34)
[1.42 (With indicator light: 1.46)]
1.18 (With indicator light: 1.22)
0.86 (With indicator light: 0.89)
[0.94 (With indicator light: 0.97)]
0.78 (With indicator light: 0.87)
1.27 (With indicator light: 1.46)
[1.39 (With indicator light: 1.60)]
1.15 (With indicator light: 1.30)
0.86 (With indicator light: 0.97)
[0.94 (With indicator light: 1.07)]
Diode (Varistor is for DIN terminal and Non-polar type.)
LED (AC of DIN connector is neon light.)
Standard
With power saving
circuit
DIN terminal (D), (Y)
M8 connector (W)
749
SY3000/5000/7000/9000 Series
SY3000 series
SY5000 series
SY7000 series
SY9000 series
Flow Rate Characteristics/Weight
Valve model Type of
actuation 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB) Port
size
Flow rate characteristics Note 1) Weight (g) Note 2)
SY3ff40-ff-01
Single
Double
Closed center
Exhaust
center
Pressure
center
2 position
3 position
C (dm3/(s·bar)) C (dm3 Cvb /(s·bar)) b Cv Grommet
84 (50)
102 (68)
104 (69)
1.0
0.77
0.26
0.19
0.30
0.28
0.30
0.30
0.24
0.18
1.1
0.85
0.73 0.24
[0.16] 0.31 0.26
[0.52] 0.18 1.1
[0.55]
1.2
[0.51] 0.24 0.24
[0.45] 0.47 0.29
[0.14] 0.89
85 (53)
107 (73)
109 (74)
L plug connector,
M plug connector
89 (57)
115 (81)
117 (82)
W
M8 connector
1 8
Note 1) [ ]: denotes the normal position. Note 2) ( ): denotes without sub-plate.
Valve model Type of
actuation 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB) Port
size
Flow rate characteristics Note 1) Weight (g) Note 2)
SY5ff40-ff-02
Single
Double
Closed center
Exhaust
center
Pressure
center
2 position
3 position
C (dm3/(s·bar)) Cvb C (dm b 3/(s·bar)) Cv Grommet
121 (58)
139 (76)
144 (82)
123 (61)
144 (81)
150 (87)
L plug connector,
M plug connector
154 (92)
186 (123)
192 (129)
DIN terminal
127 (65)
152 (89)
158 (95)
W
M8 connector
1 4
Note 1) [ ]: denotes the normal position. Note 2) ( ): denotes without sub-plate.
2.4
1.8
0.66
0.47
0.41
0.47
0.29
0.40
0.64
0.50
2.8
1.8
1.4 0.72
[0.37] 0.55 0.33
[0.48] 0.44 3.0
[1.2]
3.3
[0.84] 0.48 0.36
[0.60] 0.40 0.85
[0.28] 1.8
Valve model Type of
actuation 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB) Port
size
Flow rate characteristics Note 1) Weight (g) Note 2)
SY7ff40-ff-02
Single
Double
Closed center
Exhaust
center
Pressure
center
2 position
3 position
C (dm3/(s·bar)) Cvb C (dm b 3/(s·bar)) Cv
218 (89)
237 (108)
239 (110)
221 (92)
242 (113)
245 (116)
242 (113)
284 (155)
287 (158)
1 4
SY7ff40-ff-03
Single
Double
Closed center
Exhaust
center
Pressure
center
2 position
3 position
218 (89)
237 (108)
239 (110)
221 (92)
242 (113)
245 (116)
242 (113)
284 (155)
287 (158)
225 (96)
250 (121)
253 (124)
225 (96)
250 (121)
253 (124)
3 8
Note 1) [ ]: denotes the normal position. Note 2) ( ): denotes without sub-plate.
4.1
3.0
1.0
0.72
0.41
0.43
0.29
0.41
1.1
0.80
4.1
2.6
2.6 1.1
[0.49] 0.42 0.35
[0.48] 0.71 4.7
[1.7]
5.3
[2.3] 0.63 0.39
[0.49] 0.49 1.3
[0.65] 2.2
4.9
3.0
1.1
0.73
0.29
0.40
0.27
0.45
1.2
0.80
4.5
2.6
2.6 1.1
[0.49] 0.42 0.35
[0.48] 0.71 4.8
[1.7]
5.3
[2.3] 0.66 0.31
[0.51] 0.45 1.3
[0.64] 2.3
Valve model Type of
actuation 1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB) Port
size
Flow rate characteristics Note1) Weight (g) Note 2)
SY9ff40-ff-03
Single
Double
Closed center
Exhaust
center
Pressure
center
2 position
3 position
C (dm3/(s·bar)) Cvb C (dm b 3/(s·bar)) Cv
469(172)
488(191)
512(215)
472(175)
494(197)
518(221)
493(196)
535(239)
560(263)
3 8
SY9ff40-ff-04
Single
Double
Closed center
Exhaust
center
Pressure
center
2 position
3 position
448 (172)
467 (191)
491 (215)
453 (175)
473 (197)
497 (221)
472
515
539
476(179)
502(205)
526(229)
457(179)
481(205)
505(229)
1 2
Note 1) [ ]: denotes the normal position. Note 2) ( ): denotes without sub-plate.
7.9
7.5
2.6
1.7
0.34
0.33
0.43
0.30
2.0
1.8
9.6
7.3
7.2 2.8
[0.95] 0.34 0.23
[0.41] 1.7 13
[4.0]
12
[3.3] 1.9 0.26
[0.41] 0.40 2.8
[0.84] 6.7
8.0
7.6
2.5
1.8
0.48
0.32
0.29
0.32
2.2
1.8
10
7.3
7.3 3.6
[1.5] 0.42 0.32
[0.54] 2.0 13
[4.7]
12
[3.3] 1.9 0.33
[0.51] 0.33 3.3
[0.94] 7.4
Grommet L plug connector,
M plug connector DIN terminal W
M8 connector
Grommet L plug connector,
M plug connector DIN terminal W
M8 connector
750
(EA)5 1(P)3(EB)
2(B)(A)4
(EA)5 1(P)3(EB)
2(B)(A)4
(EA)5 1(P)3(EB)
2(B)(A)4
(EA)5 1(P)3(EB)
2(B)(A)4
(A)4 2(B)
1
(P) (EA)5 3(EB)
(EA)5 1
(P)3(EB)
2(B)(A)4
(SY9000)
(SY9000)
(EA)5 1
(P)
3(EB)
2(B)
(SY9000)
(A)4
(EA)5 1
(P)
3(EB)
2(B)(A)4
2 position single
Symbol
2 position single
2 position double
Symbol
2 position double
3 position closed center / exhaust center / pressure center
Symbol
3 position closed center
3 position exhaust center
3 position pressure center
(This figure shows a closed center type.)
Replacement Parts
No.
6
7
8
–
Description
Sub-plate Note)
Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 948.
Gasket Standard
CE/UKCA-compliant
Round head combination screw
Reference screw size
Note
H-NBR
For valve mounting
(Matt nickel plated)
Part No.
SY3fi40 SY5fi40 SY7fi40
SY5000-11-15
SY5000-11-18
SY7000-11-11
SY7000-11-14
SY3000-11-25
SY3000-11-25
AC00077
(M3 x 26)
AC00296
(M4 x 31)
SY3000-23-4
(M2 x 21)
SY9fi40
SY9000-11-2
SY9000-11-2
SY9000-18-2
(M3 x 42)
∗ Thread type
1
(P)
4
(A)
2
(B) 3
(EB)
5
(EA)
1
(P)
4
(A)
2
(B) 3
(EB)
5
(EA)
t q
u
i y
w r e
t q
u
i y
w r
Base Mounted SY3000/5000/7000/9000 Series
SY Series
Construction
Component Parts
No.
2
3
1
Description
Resin
Resin
Material
Aluminum die-casted
(SY3000: Zinc die-casted)
4 Resin –
–
Note
White
White
(SY9000: Gray)
White
Adapter plate
Body
End plate
Piston
5 Spool valve assembly Aluminum, H-NBR
Aluminum
die-casted
Caution
Mounting screw
tightening torques
M2: 0.16 N·m
M3: 0.8 N·m
M4: 1.4 N·m
SY3000-27-1 ∗ SY5000-27-1 ∗ : SY7000-27-1
: SY7000-27-2
1 4
3 8
∗
∗
3 8
1 2
: SY9000-27-1
: SY9000-27-2
∗
∗
1
(P)
4
(A)
2
(B) 3
(EB)
5
(EA)
t q
u
i y
w r
751 B
+ −
+ −
+ −
+ −
+ −
+ −
ARBY3000 05 2 P ARBY5000 00 2 P
ARBY7000 00 2 P
Note) ARBY is not CE/UKCA-compliant.
How to Order Interface Regulator
SY3000 series SY5000 series
P
A1
B1
P port
A port (P controlled type, A port regulation)
B port (P controlled type, B port regulation)
Pressure gauge connection port Regulating port
05
06
M1
ARBY3000-05-fi-2 ARBY3000-M1-fi-2 ARBY5000-00-fi-2 ARBY5000-M1-fi-2
Pressure gauge (G15-10-01) [for odd number station]
Pressure gauge (G15-10-01) [for even number station]
Plug (M-5P)
P
A1
B1
P port
A port (P controlled type, A port regulation)
B port (P controlled type, B port regulation)
Pressure gauge connection port Regulating port
00
M1
Pressure gauge (G15-10-01)
Plug (M-5P)
SY7000 series
P
A1
B1
P port
A port (P controlled type, A port regulation)
B port (P controlled type, B port regulation)
Pressure gauge connection port Regulating port
00
M1
ARBY7000-00-fi-2 ARBY7000-M1-fi-2
Pressure gauge (G15-10-01)
Plug (M-5P)
Caution
Mounting screw
tightening torques
M2: 0.16 N·m
M3: 0.8 N·m
M4: 1.4 N·m
Note) The M8 connector for wiring cannot be mounted for the
ARBY3000 series.
Accessory
Series
ARBY3000
ARBY5000
Gasket
SX3000-57-4
SX5000-57-6
Round head combination screw
Reference screw size
SY3000-23-10
(M2 x 36)
AC00283
(M3 x 48.5)
ARBY7000 SX7000-57-5 AC00282
(M4 x 58)
SY3000/5000/7000/9000 Series
752
With interface regulator PE 17
19
(Pilot EXH port)
<In the case of external pilot type>
M5 x 0.8
B
A EA P EB
AB
35 5
(Lead wire length)
3
22
2
Manual override
(For mounting)
2 x ø3.2
44.7
66.9 [69.1]
G: Approx. 300
H: Approx. 600
- +
X
17
19
(External pilot port)
M5 x 0.8
(Light/surge voltage suppressor)
38.1
11 11
20.5
7.5
16.5 24.5
(P, EA, EB port)
1/8
43.550 53.5 [60.5]
41
(A, B port)
1/8
13.5
14.5
24.5
41 (36.8)
32.5
68
ø15
140.7
65 68.5 [75.5]
With plug (12.5)
58.5
20.5
76.8 [79]
20.52
1162 67 [69.2] 68.5 75.9 11
Approx. 300 (Lead wire length)
2
1111 7.5
16.5
38.1
53.5 [60.5]
64.6 [71.6]
24.5
50
20.52 1111 7.5
16.5
58 M8 x 1 40.5
24.5
7.5
16.5
24.5
(Lead wire length)
Approx. 300
Note) Refer to page 961 for
dimensions of connector types.
Dimensions: SY3000 Series
2 position single
Grommet (G), (H): SY3140(R)-fi fifi G
H -01fi
L plug connector (L):
SY3140(R)-fiLfifi-01fi
M plug connector (M):
SY3140(R)-fiMfifi-01fi
M8 connector (WO):
SY3140(R)-fiWOfifi-01fi
[ ]: AC
Base Mounted SY3000/5000/7000/9000 Series
753
41 (36.8)
32.5
65 68.5 [75.5]
With plug (12.5) 24.5
68
ø15
140.7
(A, B port)
14.5 1/8 13.5
B
A EA P EB
AB
(Lead wire length)
(For mounting)
2 x ø3.2 Manual override
44.4
88.8 [93.2]
G: Approx. 300
H: Approx. 600
35
3
22- +
PE
<In the case of external pilot type>
(Pilot EXH port)
M5 x 0.8
17
19
- +
X
(External pilot port)
M5 x 0.8
(Light/surge voltage suppressor)
38.1
17
19
(P, EA, EB port)
1/8
50 53.5 [60.5]
7.5
16.5 24.5
11 11
20.5
41
92 106.8 20.5 1111 7.5
16.5
58 M8 x 1 40.5
24.5
20.5 1111 7.5
16.5
24.5
50
20.5
11 79 89 [93.4] 11
64.6 [71.6]
7.5
16.5
24.5
108.6 [113] Approx. 300 (Lead wire length)
38.1
53.5 [60.5]
(Lead wire length)
Approx. 300
Note) Refer to page 961 for
dimensions of connector types.
2 position double
Grommet (G), (H): SY3240(R)-fi fifi-01fi G
H
L plug connector (L):
SY3240(R)-fiLfifi-01fi
M8 connector (WO):
SY3240(R)-fiWOfifi-01fi
M plug connector (M):
SY3240(R)-fiMfifi-01fi
With interface regulator
Dimensions: SY3000 Series [ ]: AC
SY3000/5000/7000/9000 Series
754
Note) Refer to page 961 for
dimensions of connector types.
- +
X
(External pilot port)
M5 x 0.8
(Light/surge voltage suppressor)
38.1
17
19
(A, B port)
1/8 14.5 13.5
- +
PE
(Pilot EXH port)
<In the case of external pilot type>
M5 x 0.8
17
19
B
A EA P EB
AB
(Lead wire length)
(For mounting)
2 x ø3.2
Manual override
42.7 10.2
32.4 [34.6]
97.3 [101.7]
G: Approx. 300
H: Approx. 600
3
22
35 3
P, EA, EB port
1/8
53.5 [60.5] 50
11 11
20.5
41
7.5
16.5 24.5
41
24.5 32.5
(36.8)
68
ø15
140.7
65 68.5 [75.5]
With plug (12.5)
20.5 1111 7.5
16.5
24.5
50
117.1 [121.5] 42.3 [44.5] 32.5 [34.7] 27.5 Approx. 300 (Lead wire length)
38.1
53.5 [60.5]
20.5
1160 97.5 [101.9] 11
64.6 [71.6]
7.5
16.5
24.5
(Lead wire length)
Approx. 300
66.5 34 41.4
115.3 20.5 1111 7.5
16.5
58 M8 x 1 40.5
24.5
Dimensions: SY3000 Series
With interface regulator
3 position closed center / exhaust center / pressure center
Grommet (G), (H): SY3 40(R)-fi fifi-01fi G
H
3
4
5
L plug connector (L):
SY3 40(R)-fiLfifi-01fi 3
4
5
M plug connector (M):
SY3 40(R)-fiMfifi-01fi 3
4
5
M8 connector (WO):
SY3 40(R)-fiWOfifi-01fi 3
4
5
[ ]: AC
Base Mounted SY3000/5000/7000/9000 Series
755
15.5
17
(External pilot port)
M5 x 0.8
X
18 9.5
(A, B port)
1/4
9.5
22
18 18 28 4.3
95.8 [98] Approx. 300 (Lead wire length)
35.2
50.6 [57.6]
18 18 28 4.3
9.5
22
61.7 [68.7]
81 86 [88.2]
(Lead wire length)
Approx. 300
- +
15.5
35.2 PE
(Light/surge voltage suppressor)
(Pilot EXH port)
<In the case of external
pilot type>
M5 x 0.8
17
A
B
8.3
35
48
4.3
63.7
85.9 [88.1]
G: Approx. 300
H: Approx. 600
(Lead wire length)
A B
EA P EB
(For mounting)
2 x ø4.3
Manual override
4
28
9.522
45.5 50.6 [57.6]
P, EA, EB port
1/4
1818
56
56
2234
(59)
73.6 [80.6]
With plug (16.5)
ø15
157
68.5
Max. 10 104.9
65
83.4
75.9
64.6
M8 x 1
22
9.5
28 1818
22
9.51818 28
4.3
94.9 87.5
55.1
37.6
Applicable cable O.D.
ø3.5 to ø7
Pg7
49.5
4.3
105.8
Note) Refer to page 961 for
dimensions of connector types.
D
Y
Dimensions: SY5000 Series
2 position single
Grommet (G), (H): SY5140(R)-fi fifi-02fi G
H
L plug connector (L):
SY5140(R)-fiLfifi-02fi
M plug connector (M):
SY5140(R)-fiMfifi-02fi
DIN terminal (D, Y):
SY5140(R)-fi fifi-02fi
M8 connector (WO):
SY5140(R)-fiWOfifi-02fi
With interface regulator
[ ]: AC
SY3000/5000/7000/9000 Series
756
- +
15.5
17
(External pilot port)
M5 x 0.8
X
18 9.5
(A, B port)
1/4
56
2234
(59)
(16.5)
73.6 [80.6]
With plug
ø15
157
- +
15.5
35.2PE
(Light/surge voltage suppressor)
(Pilot EXH port)
<In the case of external
pilot type>
M5 x 0.8
17
A
B
A B
EA P EB
G: Approx. 300
H: Approx. 600
35
48
62.8
107.2 [111.6]
(Lead wire length)
(For mounting)
2 x ø4.3
Manual override 4
18 18
28
22 50.6 [57.6]
(P, EA, EB port)
1/4 56 9.5
9.5
22
18 18 28
35.2
50.6 [57.6]
127 [131.4] Approx. 300 (Lead wire length)
18 18
28
9.5
22
61.7 [68.7]
(Lead wire length)
Approx. 300
107.4 [111.8] 97.4
Max. 10
65.4 145.2
83.4
75.9
64.6
M8 x 1
22
9.51818 28
22
9.5
28 1818147 110.4 125.2
Applicable cable O.D.
ø3.5 to ø7
Pg7
49.5 55.1
37.6
Note) Refer to page 961 for
dimensions of connector types.
D
Y
2 position double
Grommet (G), (H): SY5240(R)-fi fifi G
H -02fi
L plug connector (L):
SY5240(R)-fiLfifi-02fi
M plug connector (M):
SY5240(R)-fiMfifi-02fi
DIN terminal (D, Y):
SY5240(R)-fi fifi-02fi
M8 connector (WO):
SY5240(R)-fiWOfifi-02fi
With interface regulator
Dimensions: SY5000 Series [ ]: AC
Base Mounted SY3000/5000/7000/9000 Series
757
- +
15.5
17
(External pilot port)
M5 x 0.8
X
1818
28
2250.6 [57.6]
(P, EA, EB port)
1/4 56 9.5
A
B
48
119.8 [124.2]
G: Approx. 300
H: Approx. 600
38.2 [40.4]
59.4 16
(Lead wire length)
A B
EA P EB
(For mounting)
2 x ø4.3
Manual override
4
35
4
56
2234
(59)
73.6 [80.6]
With plug
(16.5)
ø15
157
18 9.5
(A, B port)
1/4
28 9.5
22
61.7 [68.7]
(Lead wire length)
Approx. 300
120 [124.4]
38.3 [40.5] 76.7
33.3
18 18
Max. 10 157.8
57.2
17.3 60.7
83.4
75.9
64.6
M8 x 1
9.5
1818 28
22
9.5
28 1818 137.8 47.2 83.2 39.8
55.1
37.6
22
Pg7
Applicable cable O.D.
ø3.5 to ø7
49.5
58.1
159.6
Note) Refer to page 961 for
dimensions of connector types.
2818 18 9.5
22
Approx. 300 (Lead wire length)
35.2
50.6 [57.6]
139.6 [144]
48.1 [50.3]
- +
15.5
35.2 PE
(Light/surge voltage suppressor)
(Pilot EXH port)
<In the case of
external pilot type>
M5 x 0.8
17
D
Y
[ ]: AC
3 position closed center / exhaust center / pressure center
Grommet (G), (H): SY5 40(R)-fi fifi-02fi G
H
3
4
5
L plug connector (L):
SY5 40(R)-fiLfifi-02fi 3
4
5
M plug connector (M):
SY5 40(R)-fiMfifi-02fi 3
4
5
DIN terminal (D, Y):
SY5 40(R)-fi fifi-02fi 3
4
5
M8 connector (WO):
SY5 40(R)-fiWOfifi-02fi 3
4
5
With interface regulator
Dimensions: SY5000 Series
SY3000/5000/7000/9000 Series
758
Note) Refer to page 961 for
dimensions of connector types.
With interface regulator
21
13.5
(A, B port)
3/8,1/4
- +
(Light/surge voltage suppressor)
(Pilot EXH port)
<In the case of external
pilot type>
M5 x 0.8 PE
43.1
21.5
21
11.5
26.5
20.5 20.5 33 6.4 13.5
110 [112.2] Approx. 300 (Lead wire length)
43.1
58.5 [65.5]
20.5 20.5
336.411.5
13.5
26.5
100.2 [102.4] 95.2
69.6 [76.6]
(Lead wire length)
Approx. 300
B
A
(Lead wire length)
(For mounting)
2 x ø4.3
EA EB
A B
P
10.4
G: Approx. 300
H: Approx. 600
77.9
100.1 [102.3]
Manual override
3846
61
6.4
(P, EA, EB port)
3/8,1/4
20.5 20.5
33
11.5
13.5
69
26.5
55 58.5 [65.5]
(External pilot port)
M5 x 0.8
X 21.5
21
69 (73) 26.541.2
ø15
With plug (17)
86.7 [93.7]
184.5
83.2
93
74.2
85.5
M8 x 1
26.5
13.5
11.5 20.520.5 33
63
45.5
109.1 101.7
Pg7
Applicable cable O.D.
ø3.5 to ø7
59.1
6.4
79.2
Max. 10 119.1 120
26.5
13.5
11.5 6.4 33 20.520.5
D
Y
Dimensions: SY7000 Series
2 position single
Grommet (G), (H): SY7140(R)-fi fifi G
H - 02
03fi
L plug connector (L):
SY7140(R)-fiLfifi- 02
03fi
M plug connector (M):
SY7140(R)-fiMfifi- 02
03fi
DIN terminal (D, Y):
SY7140(R)-fi fifi- 02
03fi
M8 connector (WO):
SY7140(R)-fiWOfifi- 02
03fi
[ ]: AC
Base Mounted SY3000/5000/7000/9000 Series
759
69 (73) 26.541.2
ø15
184.5
With plug (17) 86.7 [93.7]
21
13.5
(A, B port)
3/8,1/4
- + (External pilot port)
M5 x 0.8
X
21
21.5
B
A
(Lead wire length)
(For mounting)
2 x ø4.3
EA EB
A B
P
Manual override
G: Approx. 300
H: Approx. 600
77
121.4 [125.8]
3846
61
- +
(Light/surge voltage suppressor)
(Pilot EXH port)
<In the case of external
pilot type>
M5 x 0.8 PE
43.1
21.5
21
(P, EA, EB port)
3/8,1/426.5 58.5 [65.5]
20.5 20.5
33
69
11.5
13.5
20.5 20.5
33
26.5
11.5
141.2 [145.6] Approx. 300 (Lead wire length)
13.5
43.1
58.5 [65.5]
11.5
26.5
20.5 20.5 33 121.6 [126] 111.6
13.5
69.6 [76.6]
(Lead wire length)
Approx. 300
93
85.5
74.2
13.5 13.5
11.5
63
45.5
124.6 139.4
33 20.520.5
26.5
11.5
Pg7
Applicable cable O.D.
ø3.5 to ø7
59.1
26.5
20.520.5 33
Max. 10 159.4 79.6 161.2
Note) Refer to page 961 for
dimensions of connector types.
M8 x 1
D
Y
L plug connector (L):
SY7240(R)-fiLfifi- 02
03fi
M plug connector (M):
SY7240(R)-fiMfifi- 02
03fi
DIN terminal (D, Y):
SY7240(R)-fi fifi- 02
03fi
M8 connector (WO):
SY7240(R)-fiWOfifi- 02
03fi
2 position double
Grommet (G), (H): SY7240(R)-fi fifi G
H - 02
03fi
With interface regulator
Dimensions: SY7000 Series [ ]: AC
SY3000/5000/7000/9000 Series
760
69 (73) 26.541.2
ø15
184.5
With plug (17) 86.7 [93.7]
21
13.5
(A, B port)
3/8,1/4
- +
(External pilot port)
M5 x 0.8
X
21
21.5
- +
(Light/surge voltage suppressor)
(Pilot EXH port)
<In the case of external
pilot type>
M5 x 0.8 PE
43.1
21.5
21
B
A
(Lead wire length)
(For mounting)
2 x ø4.3
EA EB
A B
P
Manual override
G: Approx. 300
H: Approx. 600
3846
61 4
71.5 18.5
134.4 [138.8]
40.7 [42.9]
(P, EA, EB port)
3/8,1/4
58.5 [65.5] 26.5
20.5 20.5
33
69
11.5 13.5
3320.5 20.5
26.5
11.5
Approx. 300 (Lead wire length) 154.2 [158.6] 50.6 [52.8]
13.5
43.1
58.5 [65.5]
11.5
26.5
20.5 20.5 134.6 [139] 35.8 40.8 [43] 88.8
33 13.5
69.6 [76.6]
(Lead wire length)
Approx. 300
93
85.5
74.2
95.3
M8 x 1
33
49.7 42.3
13.5
26.5
13.5
11.520.520.5 33152.4
63
45.5
20.520.5
26.5
11.5
Pg7
Applicable cable O.D.
ø3.5 to ø7
59.7
72.8 19.8
59.1
60.6
Max. 10
174.2 172.4
Note) Refer to page 961 for
dimensions of connector types.
D
Y
L plug connector (L):
SY7 40(R)-fiLfifi- 02
03fi
M plug connector (M):
SY7 40(R)-fiMfifi- fi02
03
DIN terminal (D, Y):
SY7 40(R)-fi fifi- 02
03fi
3 position closed center / exhaust center / pressure center
Grommet (G), (H): SY7 40(R)-fi fifi G
H - 02
03fi 3
4
5
3
4
5
3
4
5
3
4
5
M8 connector (WO):
SY7 40(R)-fiWOfifi- 02
03fi 3
4
5
With interface regulator
Dimensions: SY7000 Series [ ]: AC
Base Mounted SY3000/5000/7000/9000 Series
761
29.5 29.5
44.5 11.8
75.4 [82.4]
15.5
17.5
34.5
60 Approx. 300 (Lead wire length) 140.1 [142.3]
15.529.5 29.5 44.5
34.5
11.8
86.5 [93.5]
(Lead wire length)
Approx. 300125.3 130.3 [132.5]
17.5
X
(External pilot port)
1/8
25
27
A
B
5EA 1P 3EB
4A 2B
(Lead wire length)
2 x ø5.4
(For mounting)
Manual override
16.8
11.8 108
130.2 [132.4]
G: Approx. 300
H: Approx. 600
86.5
4757
[4(A), 2(B) port]
3/8, 1/2 29
17.5
30
[1(P), 5(EA), 3(EB) port]
3/8,1/2
34.5
73.6
29.5 29.5
44.5
15.5 17.5
96.5
75.4 [82.4]
PE
(Pilot EXH port)
<In the case of external pilot type>
1/8
(Light/surge voltage suppressor)
60
27
25
- +
90.4
101.7
109.2
139.2 131.8
79.9
62.4
17.5
15.5
44.5 29.529.5
17.5
M8 x 1
Pg7
Applicable cable O.D.
ø3.5 to ø7
Max. 10
150.1 149.2
75.4
11.8
34.5
109.3
11.8
34.5
44.5 29.529.5 15.5
Note) Refer to page 961 for
dimensions of connector types.
D SY9140(R)-fiLfifi- fi SY9140(R)-fiMfifi- fi SY9140(R)-fi Yfifi- fi
Dimensions: SY9000 Series
03
04 03
04 03
04
L plug connector (L): M plug connector (M): DIN terminal (D, Y):
SY9140(R)-fiWOfifi- 03
04 fi
M8 connector (WO):
[ ]: AC
2 position single
Grommet (G), (H): SY9140(R)-fi fifi G
H - 03
04fi
SY3000/5000/7000/9000 Series
762
29.5 29.5
44.5
86.5 [93.5]
(Lead wire length)
Approx. 300 24.5 29.5 [31.7] 113.5 148 [152.4]
34.5
17.5
15.5
A
B
G: Approx. 300
H: Approx. 600 147.8 [152.2]
7.2
29.4 [31.6]
5EA 1P 3EB
2B
(Lead wire length)
(For mounting)
2 x ø5.4
Manual override 4A
86.5
4757
96.5
29.5 29.5 44.5
(Lead wire length)
39.3 [41.5] 167.6 [172] Approx. 300
15.5
17.5
34.5
60
75.4 [82.4]
[1(P), 5(EA), 3(EB) port]
3/8, 1/2
29.5 29.5
44.5
96.5
15.5 17.5
75.4 [82.4] 34.5
X
(External pilot port)
1/8
25
27
- +
60 PE
(Pilot EXH port)
<In the case of external pilot type>
1/8
(Light/surge voltage suppressor)
27
25
- +
[4(A), 2(B) port]
3/8, 1/2 29
17.5
30
90.4
101.7
109.2
165.8
38.431 120
79.9
62.4
17.5
15.5
44.5
29.5 29.5
M8 x 1
Pg7
Applicable cable O.D.
ø3.5 to ø7
15.5
17.5
34.5
Max. 10
187.6 185.8
75.4
34.5
106
44.5
29.5 29.5
Note) Refer to page 961 for
dimensions of connector types.
D
Y
Dimensions: SY9000 Series
2 position double
Grommet (G), (H): SY9240(R)-fi fifi- 03
04fi G
H
SY9240(R)-fiLfifi- 03
04fi SY9240(R)-fiMfifi- 03
04fi 03
04
L plug connector (L): M plug connector (M): DIN terminal (D, Y):
SY9240(R)-fi fifi- fi
M8 connector (WO):
SY9240(R)-fiWOfifi-
03
04fi
[ ]: AC
Base Mounted SY3000/5000/7000/9000 Series
763
45.9 [48.1] 164.3 [168.7]
(Lead wire length)
86.5 [93.5] Approx. 300 164.5 [168.9] 113.5 41
34.5 46 [48.2]
17.5
15.5
75.4 [82.4]
60
184.1 [188.5]
55.8 [58]
34.5
17.5
15.5
34.575.4 [82.4]
30
5
4757
86.5
15.5 17.5
96.5
44.5
29.5 29.5
27
25
17.5
29
25
27
44.5
29.5 29.5 44.5 29.5 29.5
3/8, 1/2
[4(A), 2(B) port]
Manual override
(Light/surge voltage suppressor)
1/8
(Pilot EXH port)
<In the case of external pilot type>
3/8, 1/2
[1(P), 5(EA), 3(EB) port]
1/8
(External pilot port)
2 x ø5.4
(For mounting)
(Lead wire length)
X
4 A 2 B
EA5 P1 EB3
PE
96.2 23.7
60
G: Approx. 300 H: Approx. 600
B +-
A +-
90.4
101.7
109.2
54.9
182.3
47.5
120
79.9
62.4
17.5
15.5
44.5
29.5 29.5
M8 x 1
Pg7
Applicable cable O.D.
ø3.5 to ø7
34.5 34.5
17.5
15.5
Max. 10 202.3
64.9
204.1
65.8
75.4
97.5 25
44.5
29.5 29.5
Note) Refer to page 961 for
dimensions of connector types.
D SY9 40(R)-fiMfifi- fi SY9 40(R)-fi Yfifi- fi
Dimensions: SY9000 Series
3 position closed center / exhaust center / pressure center
Grommet (G), (H): SY9 40(R)-fi fifi- fi 03
04
3
4
5
3
4
5
3
4
5
3
4
5
03
04
L plug connector (L):
SY9 40(R)-fiLfifi- fi
M plug connector (M): DIN terminal (D, Y):
SY9 40(R)-fiWOfifi- fi 3
4
5
03
04
M8 connector (WO):
G
H
03
04 03
04
[ ]: AC
SY3000/5000/7000/9000 Series (Lead wire length) Approx. 300
764
765
SS5Y 5 20 05
Nil —
Q CE/UKCA-compliant
CE/UKCA-compliant
Type 20
How to Order Manifold Assembly (Example)
SS5Y3-20-05 1 set (Type 20, 5-station manifold base part no.)
∗ SY3000-26-9A 1 set (Blanking plate assembly part no.)
∗ SY3120-5G-C6 2 sets (Single solenoid part no.)
∗ SY3220-5G-C6 2 sets (Double solenoid part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
Example
Cylinder port size
C6: With One-touch
fitting for ø6
Double solenoid (24 VDC)
SY3220-5G-C6 (2 sets)
Single solenoid (24 VDC)
SY3120-5G-C6 (2 sets)
Blanking plate assembly
SY3000-26-9A (1 set)
Manifold base (5 stations)
SS5Y3-20-05
Stations ... 3 2 1
Add the valve and option part number under the manifold base part number.
In the case of complex arrangement, specify them on the manifold
specification sheet.
– + – + – + – +
EA EB P
How to Order Manifold
3 SY3000
5 SY5000
7 SY7000
Manifold series
...
2 stations
20 stations
...
02
20
Stations
∗ This also includes the
number of blanking
plate assemblies.
Note) AC-type models that are
CE/UKCA-compliant
have DIN terminals only.
Rc
NPT
Nil
00N
00T NPTF
00F G
Thread type
SY3000/5000/7000 Series
5 Port Solenoid Valve
Body Ported Manifold
Bar Stock Type/Individual Wiring
······
····
···
···
[Option]
766
Body Ported SY3000/5000/7000 Series
Note) AC-type models that are CE/UKCA-compliant
have DIN terminals only. [Option]
Type 20
Electrical entry for G, H, L, M, W
Nil Without light/surge voltage suppressor
S
Z
With surge voltage suppressor
With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
Electrical entry for D, Y
Nil Without light/surge voltage suppressor
S
Z
With surge voltage suppressor (Non-polar type)
With light/surge voltage suppressor (Non-polar type)
∗ For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit.
∗ For “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in the
“Z” type.
∗ DOZ and YOZ are not available.
∗ For AC voltage valves there is no “S” option.
It is already built-in to the rectifier circuit.
Light/Surge voltage suppressor
∗ DC specifications of type D, Y, DO and YO is only
available with 12 and 24 VDC.
∗ For type Wfi, DC voltage is only available.
Note) AC-type models that are CE/UKCA-compliant have
DIN terminals only.
Rated voltage
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC
For DC For AC ( Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
50 60
SY 5 1 20 5 L 01
Made to Order
CE/UKCA-compliant
How to Order Valve
Series
3 SY3000
5 SY5000
7 SY7000
Type of actuation
1 2 position single
2 2 position double
3 3 position closed center
4 3 position exhaust center
5 3 position pressure center
∗ Power saving circuit is not available in the case
of D, Y, DO, YO or Wfi type.
Nil Standard
T With power saving circuit (24 VDC, 12 VDC only)
Coil specifications
Grommet
24, 12, 6, 5, 3 VDC/
100, 110, 200, 220 VAC
L plug connector M plug connector
24, 12 VDC/
100, 110, 200,
220 VAC
24, 12, 6, 5, 3 VDC
DIN terminal M8 connector
Note 1) The DIN terminal of the SY3000 series cannot be mounted on a standard manifold. For
details, refer to page 958.
Note 2) Enter the cable length symbols in fi. Please be sure to fill in the blank referring to page 961.
∗ LN, MN type: with 2 sockets.
∗ “Y” type is a DIN terminal conforming to EN-175301-803C (former DIN43650C).
For details, refer to page 957.
∗ For connector cable of M8 connector, refer to page 960.
∗ M8 thread conforming to IEC60947-5-2 standard is also available. Refer to page 941 for
details.
∗ Refer to page 957 for the lead wire length of L and M plug connectors.
∗ Refer to page 958 for the connector assembly with cover for L and M plug connectors.
Electrical entry
G: Lead wire
length 300 mm
H: Lead wire
length 600 mm
L: With lead wire
(Length 300 mm)
LN: Without lead wire
LO: Without connector
M: With lead wire
(Length 300 mm)
MN: Without lead wire
MO: Without connector
CE/UKCAcompliant
Manifold
mounting
SY3000
SY5000
SY7000
DC
AC
(SY5000/7000 only)
D: With connector
DO: Without connector
Y: With connector
YO: Without connector
WO: Without
connector cable
Wfi: With connector
cable Note 2)
Nil —
X90 Main valve fluororubber
(Refer to page 942.)
Note) AC-type models that are
CE/UKCA-compliant
have DIN terminals only.
∗ Except for M5
Nil —
Q CE/UKCA-compliant
Nil Non-locking push type
D Push-turn locking slotted type
E Push-turn locking lever type
Manual override
Rc
NPT
Nil
N
T NPTF
F G
Thread type
Symbol Port size
M5 x 0.8 SY3000
Applicable series
Applicable series
Applicable series
SY5000
M5
01
02 1 4 SY7000
1 8
Thread piping
One-touch fitting (Metric size)
A, B port size
Symbol Port size
SY3000
SY5000
SY7000
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
C8 One-touch fitting for ø8
C8 One-touch fitting for ø8
C10 One-touch fitting for ø10
One-touch fitting (Inch size)
Symbol Port size
SY3000
SY5000
SY7000
N3 One-touch fitting for ø
N7 One-touch fitting for ø
N3 One-touch fitting for ø
N7 One-touch fitting for ø
N9 One-touch fitting for ø
N9 One-touch fitting for ø
N11 One-touch fitting for ø
5 32\"
1 4\"
5 32\"
1 4\"
5 16\"
5 16\"
3 8\"
Applicable series
Applicable series
Note) When placing an order for body ported
solenoid valve as a single unit, mounting screw
for manifold and gasket are not attached.
Order them separately, if necessary.
ff
ff
ff
ff
—
ff
ff
ff
ff
—
ff
ff
ff
ff
—
ff
ff
ff
ff
—
—
ff
ff
ff
ff
fflGasket assembly part no.
Gasket
Round head
combination screw
Note) The gasket assembly includes
10 sets of mounting screws
and a gasket.
Series Gasket assembly part no.
SY3000-GS-1
SY5000-GS-1
SY7000-GS-1
SY3000
SY5000
SY7000
Note 1)
767
Type 20 SY3000/5000/7000 Series
Manifold Specifications
Flow Rate Characteristics
Model
Applicable valve
Manifold type
P (SUP)/R (EXH)
Valve stations
A, B port location
Port size
Manifold base weight W (g)
n: Stations
P, EA, EB port
A, B port
SS5Y3-20(-Q)
SY3fi20
SS5Y5-20(-Q)
SY5fi20
SS5Y7-20(-Q)
SY7fi20
Single base/B mount
Common SUP, Common EXH
2 to 20 stations Note1)
Valve
1 8 1 4
1 8
1 4
1 M5 x 0.8 4
C4(One-touch fitting for ø4)
C6 (One-touch fitting for ø6)
C4 (One-touch fitting for ø4)
C6 (One-touch fitting for ø6)
C8 (One-touch fitting for ø8)
C8 (One-touch fitting for ø8)
C10 (One-touch fitting for ø10)
W = 13n + 24 W = 36n + 64 W = 43n + 35
Note 1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to P port on both
sides and exhaust from EA/EB port on both sides.
Note 2) Refer to “Manifold Option” on page 795.
1 8
1 4
C6
C8
C10
0.72
1.9
3.6
0.29
0.28
0.31
0.18
0.48
0.93
0.80
2.2
3.6
0.36
0.20
0.27
0.21
0.53
1 4 0.88
Model 1, 5, 3
(P, EA, EB)
4, 2
(A, B)
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB)
Port size Flow rate characteristics
C (dm3/(s·bar)) b Cv C (dm3/(s·bar)) b Cv
SS5Y3-20(-Q)
SS5Y5-20(-Q)
SS5Y7-20(-Q)
Note) The value is for manifold base with 5 stations and individually operated 2 position type.
768
-+ -+ -+ -+ -+
-+
-+
B
A
B
A
B
A
B
A
B
A
P EB EA
P EB EA
54.3 [56.5]108.6 [113] 117.1 [121.5] Approx. 300 (Lead wire length)
33.6
49 [56]
Approx. 300 60.1 [67.1]
(Lead wire length)
44.5 [46.7]89 [93.4] 97.5 [101.9]
M8 x 1
115.3 106.8
53.4
92
46
100.5
36
53.5
(Station n) (Station 1)
L2
L1
10.2
4 x ø4.5
(For mounting)
M5 x 0.5
(A, B port)
One-touch fitting
(A, B port)
Applicable tubing O.D.
: ø4, ø5/32\"
: ø6, ø1/4\"
14.75
(Pitch)
P = 10.5
Manual
override
44.4 [46.6]97.3 [101.7] 30.7 22.2 22.2 23.5 88.8 [93.2] Approx. 300 (Lead wire length)
4.7516
1/8
(P, EA, EB port)
44
(M5 port)
16.516.5 23.5
49
12.5
Dimensions when mounting
individual EXH spacer
( )
Dimensions when mounting
individual SUP spacer
SUP port is at the end plate of
single solenoid.
3
EXH port
M5 x 0.8
(Both sides) 40 [47]
611
0.5 0.5
611
SUP port
M5 x 0.8 C6:45.1 N7:48.9 (3.2)
C6:45.1 N7:48.9 (3.2) 2020
1
(Light/surge voltage suppressor)
33.6C6:54.1 N7:57.9 49 [56] (3.2) 20
Body Ported SY3000/5000/7000 Series Type 20
Grommet (G)
SY3000: SS5Y3-20- - Stations [ ]: AC
L plug connector (L) M plug connector (M) M8 connector (WO)
Note) Refer to page 961 for
dimensions of connector types.
L1
L2
2 stations
40
30.5
3
50.5
41
4
61
51.5
5
71.5
62
6
82
72.5
7
92.5
83
8
103
93.5
9
113.5
104
10
124
114.5
11
134.5
125
12
145
135.5
13
155.5
146
14
166
156.5
15
176.5
167
16
187
177.5
17
197.5
188
18
208
198.5
19
218.5
209
20 stations
229
219.5
Stations n
769
P
A
B
A
B
A
B
A
B
A
B P EB EA
- + - + - + - + - +
- +
- + E
PEB EA
87.9
69.1
80.4
147 159.6
73.5
815.5
56.4 (4.9)
1
SUP port
1/8
26.5
815.5
1
EXH port
1/8
(Both sides) 56.4 44.1 [51.1] (4.9) 26.5
(4.9)
55.1 [62.1] 67.4
39.759.5
(Light/surge voltage suppressor)
(Station n) (Station 1)
26.5
14.5 16.2 32.3
22
107.2 [111.6] 53.6 [55.8]
Manual override
4 x ø4.5
(For mounting)
(Pitch)
P = 16
One-touch fitting (A, B port)
Applicable tubing O.D.: ø4, ø5/32\"
ø6, ø1/4\"
ø8, ø5/16\"
1/8
(A, B port) 20
L2
L1
10
31.4 119.8 [124.2] Approx. 300 44 (DIN : 45.3) 31.4
(Lead wire length)
(DIN : 32.7)
(DIN : 32.7)
1/4
(P, EA, EB port) 21 21 60
16.5
11.5 30
63.5 [65.7] 127 [131.4] 139.6 [144]
39.7
55.1 [62.1]
Approx. 300 (Lead wire length)
66.2 [73.2]
53.7 [55.9] 107.4 [111.8] 120 [124.4]
Approx. 300 (Lead wire length) 59.6
42.1
137.8 125.2
62.6
123 110.4
55.2
M8 x 1
157.8 Max. 10
145.2
72.6
Pg7
Applicable cable O.D.
ø3.5 to ø7
Type 20 SY3000/5000/7000 Series
SY5000: SS5Y5-20- - Stations
Grommet (G)
[ ]: AC
Dimensions when mounting
individual EXH spacer
( )
Dimensions when mounting
individual SUP spacer
SUP port is at the end plate of
single solenoid.
L1
L2
2 stations
60
40
3
76
56
4
92
72
5
108
88
6
124
104
7
140
120
8
156
136
9
172
152
10
188
168
11
204
184
12
220
200
13
236
216
14
252
232
15
268
248
16
284
264
17
300
280
18
316
296
19
332
312
20 stations
348
328
Stations n
Note) Refer to page 961 for
dimensions of connector types.
L plug connector (L) M plug connector (M) DIN terminal (D, Y) M8 connector (WO)
770
- + - + - + - + - + E
- +
- + P
A
B
A
B
A
B
A
B
A
B
4 x ø4.5 Manual override (For mounting)
4.5
(Light/surge voltage suppressor)
58.5 [65.5] 74.6
43.1 26.5
67
(5.5)
9.5
18.5
9.5
18.5 50.5 [57.5] 66.6 66.6 26.5 26.5 (5.5) (5.5)
154.2 [158.6] 141.2 [145.6] 70.6 [72.8]
43.1
58.5 [65.5]
60.8 [63] 121.6 [126] 134.6 [139]
69.6 [76.6]
93
85.5 Pg7 74.2 Max. 10 79.7 172.4 159.4 174.2 161.2 80.6
152.4 139.4
69.7
63
45.5
137.6 124.6
62.3
M8 x 1
Approx. 300 (Lead wire length)
Approx. 300
(Lead wire length)
Applicable cable O.D.
ø3.5 to ø7
(Station n) (Station 1)
1
EXH port
1/4
(Both sides)
1
SUP port
1/4
1/4
(P, EA, EB port) 60 21 2130
11.5
16.5
L2
L1
P EB EA P EA EB 2039.4 60.7 [62.9] 121.4 [125.8] 134.4 [138.8] 38.5 (DIN: 39.8) 51.5 (DIN: 52.8) 2119
(Lead wire length) Approx. 300
38.5
(DIN: 39.8)
(Pitch)
P = 19 1/4
(A, B port)
18
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø8, ø5/16\"
ø10, ø3/8\"
Body Ported SY3000/5000/7000 Series Type 20
SY7000: SS5Y7-20- - Stations
Grommet (G)
[ ]: AC
Dimensions when mounting
individual EXH spacer
( )
Dimensions when mounting
individual SUP spacer
SUP port is at the end plate of
single solenoid.
L plug connector (L) M plug connector (M) DIN terminal (D, Y) M8 connector (WO)
Note) Refer to page 961 for
dimensions of connector types.
L1
L2
2 stations
55
46
3
74
65
4
93
84
5
112
103
6
131
122
7
150
141
8
169
160
9
188
179
10
207
198
11
226
217
12
245
236
13
264
255
14
283
274
15
302
293
16
321
312
17
340
331
18
359
350
19
378
369
20 stations
397
388
Stations n
771
Type 23
How to Order Manifold
Rc
NPT
Nil
00N
00T NPTF
00F G
...
Stations
2 stations
20 stations
...
Symbol
02
20
Valve stations
∗ This also includes the number
of blanking plate assemblies.
Note) AC-type models that are
CE/UKCA-compliant
have DIN terminals
only.
Nil —
Q CE/UKCA-compliant
CE/UKCA-compliant
How to Order Manifold Assembly (Example)
Example
- + - + - + - +
P EA EB 12 3
Stations
Cylinder port size
C12: With One-touch fitting for ø12
Double solenoid (24 VDC)
SY9220-5LOZ-C12 (2 sets)
Single solenoid (24 VDC)
SY9120-5LOZ-C12 (2 sets)
Blanking plate assembly
SY9000-26-1A(1 set)
Manifold base (5 stations)
SS5Y9-23-05
Add the valve and option part number under the manifold base part
number. In the case of complex arrangement, specify them on the
manifold specification sheet.
SS5Y9-23-05 1 set (Type 23, 5-station manifold base part no.)
∗ SY9000-26-1A 1 set (Blanking plate assembly part no.)
∗ SY9120-5LOZ-C12 2 sets (Single solenoid part no.)
∗ SY9220-5LOZ-C12 2 sets (Double solenoid part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
SY9000 Series
5 Port Solenoid Valve
Body Ported Manifold
Stacking Type/Individual Wiring
SS5Y9 23 05
9 SY9000
Manifold series
Symbol Mounting
Nil
D
DO
D∗
Option
Thread type
Type 23/External pilot capable
············
··········
···
···
When a longer DIN rail is desired than the
specified stations, specify the station
number to be required into ∗ mark.
Direct mounting
DIN rail mounting (with DIN rail)
DIN rail mounting (without DIN rail)
[Option]
772