Solar for everybody
Product brochure
The power of the sun for the future of our planet
Solar for everybody
The future is solar for everybody
At Solplanet, we are driven by a simple idea: solar for everybody. We strive to create the best possible experience for distributors, installers and end users. That's why our products are easy-to-install, safe & reliable and user- friendly.
Solplanet photovoltaic inverters are manufactured in compliance with international high-quality standards. Our annual production capacity exceeds 32GW. So, chances are we can meet your demand.
You can depend on Solplanet
Solplanet is a brand of AlSWEl, which is formerly known as SMA's Chinese subsidiary and has successfully been manufacturing high-quality and reliable products for renowned brands like SMA and Zeversolar.
Today, AISWEl is a leading R&D and manufacturing company focusing on clean energy. Headquartered in Shanghai, China, with four R&D centers, one manufacturing base, and offices in Asia, Europe, South America, Africa, and Oceania, AlSWEl and Solplanet serve customers in many countries and regions across the globe.
Solplanet makes things easy
Solplanet products are easy-to-install, safe & reliable and user-friendly. We offer a variety of quality products with industry leading warranties that you can depend on: string inverters, hybrid inverters, batteires, AC EV chargers, and connect & monitoring systems.
Easy-to-install Safe & Reliable User-friendly
We strive to create the best possible experience for distributors, installers and end users. That's why our products are easy-to-install, safe & reliable and user-friendly.
Easy-to-install
Safe & reliable
User-friendly
• Quick & easy-to-install with standard tools
• Quick setup and commissioning with Solplanet Apps
• Compact wall mount design
•International quality standards
• Integrated DC switch
• IP rated design for outdoor use
User friendly app interface
Online monitoring via Wi-Fi and Solplanet Apps
Award winning inverter design
Our product range:
We offer single phase and three phase inverters alongside our monitoring products:
Single Phase Inverters Page 8
Three Phase Inverters Page 20
C&I Energy Storage System Page 72
Hybrid Inverters Page 42
Smart EV Charger Page 76
Connect & Monitor Page 80
Energy Storage
Batteries
Page 60
Single phase inverters
Perfect for home & small business applications
ASW S-S2 SERIES
ASW600S-S2
ASW800S-S2
ASW S-S SERIES
ASW1000S-S
ASW1500S-S
ASW2000S-S
ASW3000S-S
ASW S SERIES
ASW6000-S
ASW8000-S
ASW10000-S
ASW S-G2 SERIES
ASW1000-S-G2
ASW1500-S-G2
ASW2000-S-G2
ASW2500-S-G2
ASW S-G2 SERIES
ASW3000-S-G2
ASW3680-S-G2
ASW4000-S-G2
ASW5000-S-G2
ASW6000-S-G2
User-friendly
ASW S-S2 Series
Safe & reliable
● Suitable for PV balcony systems
● Quick and easy to install with standard tools
• Smart setup, commissioning and monitoring via Solplanet App
● A4 size, compact and super light weight at 3.9 kg
● 250 % PV array oversizing for higher yields
Integrated DC switch
● Higher yield due to very low 35 V start-up voltage
●IP66 rated design for indoor and outdoor use
16 A input current, ideal for highpower PV modules
24/7 PV plant monitoring via the Solplanet App
• Noise level < 20 dB
ShadeSol - improved generation under non-ideal conditions
Smart meter interface for zero export applications
| I(npp t(dcl) | Max. PV array power | 1500 Wp STC | 2000 Wp STC |
| Max. input voltage | 500 V | ||
| MPP voltage range | 35 V - 420 V / 360 V | ||
| Full load MPP voltage range | 65 V - 400V | ||
| Min. input voltage | 30 V | ||
| Initial. feed in voltage | 35V | ||
| Max. operating input current | 16 A | ||
| Max. short circuit current | 20 A | ||
| No. of independent MPPT inputs / strings per MPPT input | 1/1 | ||
| OUut tut(AC) | Rated active power | 600 W | 800 W |
| Rated apparent power | 600 VA | 800 VA | |
| Max. apparent power | 600 VA | 800 VA | |
| AC nominal voltage | 230 V | ||
| AC voltage range | 180 V - 260 V | ||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz | ||
| Max. output current (A) | 2.6 A | 3.5 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | ||
| Feed-in phases | 1 | ||
| Harmonic distortion (THD) at rated output | <3% | ||
| Efi prction | Max. efficiency / European efficiency | 97.2 % / 96.5 % | |
| DC switch | ● | ||
| Ground fault monitoring / grid monitoring | ●/● | ||
| DC reverse polarity protection / AC short circuit protection | ●/0 | ||
| All-pole-sensitive residual-current monitoring unit | ●/● | ||
| Surge protection | ●/ Type III | ||
| Anti-Islanding protection | ● | ||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | I/ AC:II; DC:II | ||
| Gel derata | Dimensions (W / H / D) | 288 / 218 / 97 mm | |
| Weight | 4.0 kg | ||
| Operating temperature range | -25℃~60°℃ | ||
| Self-consumption (at night) | <1W | ||
| Topology | Non-isolated | ||
| Cooling concept | Natural convection | ||
| Degree of protection (according to IEC 60529) | IP66 | ||
| Relative humidity | 0 - 100 % (Non-condensing) | ||
| Max. operating altitude | 3000 m | ||
| Featues | DC connector | Plug-in connector | |
| AC connector | Plug-in connector | ||
| Mounting type | Wall-mount bracket | ||
| LED indicators (Status / Fault / Communication) | ● | ||
| 24/7 monitoring | |||
| Communication interface | O/O/O(RS4851/Wi-Fi /LAN) | ||
| Certificates and approvals (more available on request) | CE / IEC62109-1/IEC62109-2/VDE-AR-N 4105:2018 | ||
ASW S-S Series
Easy-to-install
Safe & reliable
User-friendly
Quick and easy-to-install with standard tools
Smart setup, commissioning and monitoring via Solplanet App
● Compact wall mount design
Internationally accredited standards
●Integrated DC switch
IP65 rated design for indoor and outdoor use
● User friendly App interface
Distinguishable connection interfaces
ShadeSol - improved generation under non-ideal conditions
| Technical Datasheet ASW1000S-S ASW1500S-S ASW2000S-S ASW3000S-S | |||||
| (np t(dl) | Max. PV array power | 1500 Wp STC | 2250 Wp STC | 3000 Wp STC | 4500 Wp STC |
| Max. input voltage | 580 V | ||||
| MPP voltage range / rated input voltage | 80 V - 550 V / 360 V | ||||
| Min. input voltage | 80 V | ||||
| Initial. feed in voltage | 100 V | ||||
| Max. operating input current | 12 A | ||||
| Max. short circuit current | 18 A | ||||
| No. of independent MPPT inputs / strings per MPPT input | 1/1 | ||||
| OUut tuAC) | Rated active power | 1000 W | 1500 W | 2000 W | 3000 W |
| Rated apparent power | 1000 VA | 1500 VA | 2000 VA | 3000 VA | |
| Max. apparent power | 1000 VA | 1500 VA | 2000 VA | 3000 VA | |
| AC nominal voltage | 220 V/ 230 V /240 V | ||||
| AC voltage range | 180 V - 290 V | ||||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | ||||
| Max. output current | 5A | 7.5 A | 10 A | 13.6 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | ||||
| Feed-in phases | 1 | ||||
| Harmonic distortion (THD) at rated output | <3% | ||||
| Efir ction | Max. efficiency / European efficiency | 97.4 % / 95.4 % | 97.6 % / 96.3 % | 97.6 % / 96.8 % | 97.6 % / 97.1 % |
| DC switch | ● | ||||
| Ground fault monitoring / grid monitoring | ●/● | ||||
| DC reverse polarity protection / AC short circuit protection | ●/0 | ||||
| All-pole-sensitive residual-current monitoring unit | ● | ||||
| Anti-islanding Protection | ● | ||||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | I/ AC:I; DC:II | ||||
| Ge erata | Dimensions (W / H / D) | 320 /264/94 mm | |||
| Weight | 6.5 kg | ||||
| Operating temperature range | -25℃~60℃ | ||||
| Self-consumption (at night) | <1W | ||||
| Topology | Non-isolated | ||||
| Cooling concept | Natural convection | ||||
| Degree of protection (according to IEC 60529) | IP65 | ||||
| Relative humidity | 0 - 100 % (Non-condensing) | ||||
| Max. operating altitude | 3000 m | ||||
| Featues | DC connector | Plug-in connector | |||
| AC connector | Plug-in connector | ||||
| Mounting type | Wall-mount bracket | ||||
| LED indicators (Status / Fault / Communication) | ● | ||||
| Communication interface | 0/0/O(RS4851 /Wi-Fi / LAN) | ||||
| Certificates and approvals (more available on request) | CE, IEC62109, IEC61000, EN50549,AS/NZS 4777, C10/C11, IEC61727, IEC62116, IEC61683 | ||||
1 RS485 to approved smart meters for export power control applications
ASW S Series
Easy-to-install
Quick and easy-to-install with standard tools
● Smart setup, commissioning and monitoring via Solplanet App
Compact wall mount design
Safe & reliable
Internationally accredited standards
Integrated DC switch
IP66 rated design for indoor and outdoor use
User-friendly
16A input current, compatible with bifacial and large area PV modules
● 3 MPPTs for flexible PV array design
ShadeSol -improved generation under non-ideal conditions
| Technical Datasheet ASW6000-S | ASW8000-S ASW10000-S | |||
| I(np t(dcl) | Max. PV array power | 9000 Wp STC | 12000 Wp STC | 15000 Wp STC |
| Max. input voltage | 600 V | |||
| MPP voltage range / rated input voltage | 80 V - 560 V / 360 V | |||
| Min. input voltage | 80 V | |||
| Initial. feed in voltage | 100 V | |||
| Max. operating input current | 16 A | |||
| Max. short circuit current | 22.5 A | |||
| No. of independent MPPT inputs / strings per MPPT input | 3/1 | |||
| OUut tut(AC) | Rated active power | 6000 W | 8000 W | 10000 W |
| Rated apparent power | 6000 VA | 8000 VA | 10000 VA | |
| Max. apparent power | 6000 VA | 8000 VA | 10000 VA | |
| AC nominal voltage | 220 V / 230 V / 240 V | |||
| AC voltage range | 180 V - 295 V | |||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | |||
| Max. output current | 30 A | 40 A | 50 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | |||
| Feed-in phases | 1 | |||
| Harmonic distortion (THD) at rated output | <3% | |||
| Efie prction | Max. efficiency / European efficiency | 97.7 % / 97.3 % | ||
| DC switch | ● | |||
| Ground fault monitoring / grid monitoring | ●/● | |||
| DC reverse polarity protection / AC short circuit protection | ●/● | |||
| All-pole-sensitive residual-current monitoring unit | ● | |||
| Anti-Islanding protection | ● | |||
| Surge protection | ●/ Type II | |||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | I/ AC: I; DC: II | |||
| Gee Gerdata | Dimensions (W / H / D) | 503 / 435 / 183 mm | ||
| Weight | 19.0 kg | |||
| Operating temperature range | -25℃~60℃ | |||
| Self-consumption (at night) | <1W | |||
| Topology | Non-isolated | |||
| Cooling concept | Natural convection | |||
| Degree of protection (according to IEC 60529) | IP66 | |||
| Relative humidity | 0 - 100 % (Non-condensing) | |||
| Max. operating altitude | 3000 m | |||
| Features | DC connector | Plug-in connector | ||
| AC connector | Plug-in connector | |||
| Mounting type | Wall-mount bracket | |||
| LED indicators (Status / Fault / Communication) | ● | |||
| 24/7 monitoring | ● | |||
| Communication interface | O/O/O(RS4851 / Wi-Fi / LAN) | |||
| Certificates and approvals (more available on request) | CE, EN50549, IEC62109, IEC62116, IEC61727, IEC61683, IEC60068, IEC61000, AS/NZS4777, C10/C11 | |||
1 RS485 to approved smart meters for export power control applications
ASW S-G2 Series
Models:
ASW1000-S-G2
ASW1500-S-G2
ASW2000-S-G2
ASW2500-S-G2
Easy-to-install
Quick & easy-to-install with standard tools
Smart setup, commissioning and monitoring via Solplanet App
Compact wall mount design
Safe & reliable
Internationally accredited standards
Integrated DC switch
● IP66 rated design for indoor and outdoor use
User-friendly
16 A input current, compatible with bifacial and large area PV modules
● Optional AC Power Supply
ShadeSol - improved generation under non-ideal conditions
Supports zero export applications
| Technical Datasheet ASW1000-S-G2 ASW1500-S-G2 ASW2000-S-G2 ASW2500-S-G2 | |||||
| (np t(cl) | Max. PV array power | 1500 Wp STC | 2250 Wp STC | 3000 Wp STC | 3750 Wp STC |
| Max. input voltage | 600V | 600 V | 600 V | 600 V | |
| MPP voltage range | 60 V -560 V / 360 V | ||||
| Full load MPP voltage range | 200 V - 500 V | ||||
| Min. input voltage | 60 V | ||||
| Initial. feed in voltage | 100 V | ||||
| Max. operating input current | 16 A | ||||
| Max. short circuit current | 24 A | ||||
| No. of independent MPPT inputs / strings per MPPT input | 1/1 | ||||
| OUut t(AC) | Rated active power | 1000 W | 1500 W | 2000 W | 2500 W |
| Rated apparent power | 1000 VA | 1500 VA | 2000 VA | 2500 VA | |
| Max. apparent power | 1000 VA | 1500 VA | 2000 VA | 2500 VA | |
| AC nominal voltage | 220 V / 230 V / 240 V | ||||
| AC voltage range | 180 V - 295 V | ||||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | ||||
| Max. output current | 5A | 7.5 A | 10 A | 12.5 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | ||||
| Feed-in phases | 1 | ||||
| Harmonic distortion (THD) at rated output | <3% | ||||
| Efhetc ption | Max. efficiency / European efficiency | 97.6 % / 97.1 % | |||
| DC switch | ● | ||||
| Ground fault monitoring / grid monitoring | ●/● | ||||
| DC reverse polarity protection / AC short circuit protection | ●/0 | ||||
| All-pole-sensitive residual-current monitoring unit | ● | ||||
| Arc fault circuit interrupter (AFCI) | o | ||||
| Anti-Islanding protection | ● | ||||
| Surge protection | ● / Type II | ||||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | I/ AC: III;; D: I | ||||
| Ge drata | Dimensions (W / H / D) | 368 / 325 / 145 mm | |||
| Weight | 9.5 kg | ||||
| Operating temperature range | -25℃~60℃ | ||||
| Self-consumption (at night) | <1W | ||||
| Topology | Non-isolated | ||||
| Cooling concept | Natural convection | ||||
| Degree of protection (according to IEC 60529) | IP66 | ||||
| Relative humidity | 0 -100 % (Non-condensing) | ||||
| Max. operating altitude | 4000 m | ||||
| Features | DC connector | Plug-in connector | |||
| AC connector | Plug-in connector | ||||
| Mounting type | Wall-mount bracket | ||||
| LED indicators (Status / Fault / Communication) | ● | ||||
| 24/7 monitoring | ● | ||||
| Communication interface | O/O/O(RS4851 / Wi-Fi /LAN) | ||||
| Certificates and approvals (more available on request) | IEC 62109-1/2, EN50549-1, C10/C11, VDE-AR-N 4105 | ||||
1 RS485 to approved smart meters for export power control applications
ASW S-G2 Series
Easy-to-install
Quick and easy-to-install with standard tools
Smart setup, commissioning and monitoring via Solplanet App
● Compact wall mount design
Safe & reliable
Internationally accredited standards
Integrated DC switch
● IP66 rated design for indoor and outdoor use
User-friendly
16 A input current, compatible with bifacial and large area PV modules
Optional AC Power Supply
ShadeSol-improved generation under non-ideal conditions
Supports zero export applications
● 2 MPPTs for flexible PV array design
| Technical Datasheet ASW3000-S-G2 ASW3680-S-G2 ASW4000-S-G2 ASW5000-S-G2 ASW6000-S-G2 | ||||||
| Inup t(c) | Max. PV array power | 4500 Wp STC | 5520 Wp STC | 6000 Wp STC | 7500 Wp STC | 9000 Wp STC |
| Max. input voltage | 600 V | |||||
| MPP voltage range / rated input voltage | 60 V - 560 V / 360 V | |||||
| Min. input voltage | 60 V | |||||
| Initial. feed in voltage | 100 V | |||||
| Max. operating input current | 16 A | |||||
| Max. short circuit current | 24A | |||||
| No. of independent MPPT inputs / strings per MPPT input | 2/1 | |||||
| OUut tuAC) | Rated active power | 3000 W | 3680 W | 4000 W | 5000 W | 6000 W |
| Rated apparent power | 3000 VA | 3680 VA | 4000 VA | 5000 VA | 6000 VA | |
| Max. apparent power | 3000 VA | 3680 VA | 4000 VA | 5000 VA | 6000 VA | |
| AC nominal voltage | 220 V / 230 V / 240 V | |||||
| AC voltage range | 180 V- 295 V | |||||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | |||||
| Max. output current | 15 A | 16 A | 20 A | 25 A | 30 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | |||||
| Feed-in phases | 1 | |||||
| Harmonic distortion (THD) at rated output | <3% | |||||
| Efir pction | Max. efficiency / European efficiency | 98.2 % / 97.5 % | ||||
| DC switch | ● | |||||
| Ground fault monitoring / grid monitoring | ●/● | |||||
| DC reverse polarity protection / AC short circuit Protection | ●/● | |||||
| All-pole-sensitive residual-current monitoring unit | ● | |||||
| Surge protection | ●/ Type II | |||||
| Arc fault circuit interrupter (AFCI) | o | |||||
| Anti-Islanding protection | ● | |||||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | 1/ AC: II; DC: II | |||||
| Gen raata | Dimensions (W / H / D) | 368 / 325 /145 mm | ||||
| Weight | 9.5 kg | |||||
| Operating temperature range | -25°℃~60℃ | |||||
| Self-consumption (at night) | <1W | |||||
| Topology | Non-isolated | |||||
| Cooling concept | Natural convection | |||||
| Degree of protection (according to IEC 60529) | IP66 | |||||
| Relative humidity | 0 -100 % (Non-condensing) | |||||
| Max. operating altitude | 4000 m | |||||
| Features | DC connector | Plug-in connector | ||||
| AC connector | Plug-in Connector | |||||
| Mounting type | Wall-mount bracket | |||||
| LED Indicators (Status / Fault / Communication) | ● | |||||
| 24/7 monitoring | ● | |||||
| Communication interface | O/O/O(RS4851 / Wi-Fi / LAN) | |||||
| Certificates and approvals (more available on request) | AS/NZS 4777.2,IEC 62109-1/2, IEC 61727, IEC 62116, NB/T32004 | |||||
1 RS485 to approved smart meters for export power control applications
High yield, reliable residential and commercial inverters
ASW LT-G2 Pro SERIESASW3K / 4K / 5K / 6K / 8K / 10K-LT-G2 ProASW12K/13K/15K/17K/20K-LT-G2 Pro
ASW LT-G3 SERIES ASW25K/27K/30K/33K/ 36K / 40K-LT-G3
ASW LT-G3 SERIES ASW45K / 50K / 60K-LT-G3
ASW LT SERIES
ASW75K / 80K / 100K / 110K-LT
ASW125K-LT
ASW LT SERIES ASW150K-LT
ASW HT SERIES ASW250K/333K/350K/360K-HT
ASW MT SERIES Transformer Station ASW3000K/6000K/9000K-MT
Three phase inverters 3 to 10 kW
ASW LT-G2 Pro Series
Models: ASW3K-LT-G2 Pro ASW4K-LT-G2 Pro ASW5K-LT-G2 Pro ASW6K-LT-G2 Pro ASW8K-LT-G2 Pro ASW10K-LT-G2 Pro
Easy-to-install
Safe & reliable
User-friendly
Quick and easy-to-install with standard tools
Smart setup, commissioning and monitoring via Solplanet App
● Compact wall mount design
Internationally accredited standards
150 % PV array oversizing for higher yields
IP66 rated design for indoor and outdoor use
Max.20 A input current, ideal for bifacial and large area PV modules
●Wide MPP voltage range 150V-1000V
ShadeSol - improved generation under non-ideal conditions
| ASW ASW ASW ASW ASW ASWTechnical Datasheet 3K-LT-G2 Pro 4K-LT-G2 Pro 5K-LT-G2 Pro 6K-LT-G2 Pro 8K-LT-G2 Pro 10K-LT-G2 Pro | |||||||
| (npt(c) | Max. PV array power | 4500 Wp STC | 6000 Wp STC | 7500 Wp STC | 9000 Wp STC | 12000 Wp STC | 15000 Wp STC |
| Max. input voltage | 1100 V | ||||||
| MPP voltage range / rated input voltage | 150 V - 1000 V / 630 V | ||||||
| Min. input voltage | 125 V | ||||||
| Initial. feed-in voltage | 180 V | ||||||
| Max. operating input current | 16 A / 16 A | 20 A/ 16 A | |||||
| Max. short circuit current | 25 A / 25 A | 30 A/ 25 A | |||||
| No. of independent MPPT inputs / strings per MPPT input | 2/A:1;B:1 | ||||||
| OUutu(AC) | Rated active power | 3000 W | 4000 W | 5000 W | 6000 W | 8000 W | 10000 W |
| Rated apparent power | 3000 VA | 4000 VA | 5000 VA | 6000 VA | 8000 VA | 10000 VA | |
| Max. apparent power | 3000 VA | 4000 VA | 5000 VA | 6000 VA | 8000 VA | 10000 VA | |
| AC nominal voltage | 220 V / 380 V230 V / 400 V240 V / 415 V | ||||||
| AC voltage range | 160 V - 300 V | ||||||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | ||||||
| Max. output current | 4.8 A | 6.4 A | 8.0 A | 9.6 A | 12.8 A | 16 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | ||||||
| Feed-in phases | 3/3-N-PE | ||||||
| Harmonic distortion (THD) at rated output | <3% | ||||||
| Efir ction | Max. efficiency / European efficiency | 98.3 % / 97.9 % | 98.6 % / 98.2 % | ||||
| DC Switch | ● | ||||||
| Ground fault monitoring / grid monitoring | ●/● | ||||||
| DC reverse polarity protection / AC short circuit protection | ●/0 | ||||||
| All-pole-sensitive residual-current monitoring unit | ● | ||||||
| Arc fault circuit interrupter (AFCI) | o | ||||||
| Anti-Islanding protection | ● | ||||||
| Surge protection | ●/ Type II | ||||||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | I/AC :II; DC :II | ||||||
| Gerne eGerdata | Dimensions (W / H / D) | 503 / 435 / 183 mm | |||||
| Weight | 16.0 kg | ||||||
| Operating temperature range | -25℃~60℃ | ||||||
| Self-consumption (at night) | <1W | ||||||
| Topology | Non-isolated | ||||||
| Cooling concept | Natural convection | ||||||
| Degree of protection (according to IEC 60529) | IP66 | ||||||
| Relative humidity | 0 - 100 % (Non-condensing) | ||||||
| Max. operating altitude | 3000 m | ||||||
| Features | DC connector | Plug-in connector | |||||
| AC connector | Plug-in connector | ||||||
| Mounting type | Wall-mount bracket | ||||||
| LED indicators (Status / Fault / Communication) | ● | ||||||
| 24/7 monitoring | ● | ||||||
| Communication interface | O/O/O(RS4851 /Wi-Fi / LAN) | ||||||
| Certificates and approvals (more available on request) | CE, EN50549, G98/99, VDE-AR-N4105, AS/NZS 4777, C10/C11, VFR 2014 & UTE C15,IEC62109,IEC62116,IEC61727,IEC61683,IEC60068,IEC61000,NB/T 32004 | ||||||
1 RS485 to approved smart meters for export power control applications
Three phase inverters 12 to 20 kW
ASW LT-G2 Pro Series
Models: ASW12K-LT-G2 Pro ASW13K-LT-G2 Pro ASW15K-LT-G2 Pro ASW17K-LT-G2 Pro ASW20K-LT-G2 Pro
Easy-to-install
Safe & reliable
User-friendly
Quick and easy-to-install with standard tools
Smart setup, commissioning and monitoring via Solplanet App
● Compact wall mount design
Internationally accredited standards
150 % PV array oversizing for higher yields
IP66 rated design for indoor and outdoor use
20 A input current, ideal for bifacial and large area PV modules
●Wide MPP voltage range 150V-1000V
ShadeSol - improved generation under non-ideal conditions
| ASW ASW ASW ASW ASWTechnical Datasheet 12K-LT-G2 Pro 13K-LT-G2 Pro 15K-LT-G2 Pro 17K-LT-G2 Pro 20K-LT-G2 Pro | ||||||
| (npt(dc) | Max. PV array power | 18000 Wp STC | 19500 Wp STC | 22500 Wp STC | 25500 Wp STC | 30000 Wp STC |
| Max. input voltage | 1100 V | |||||
| MPP voltage range / rated input voltage | 150 V - 1000 V / 630 V | |||||
| Min. input voltage | 125 V | |||||
| Initial. feed-in voltage | 180 V | |||||
| Max. operating input current | 32 A / 20 A | 32 A / 20 A | 32 A / 20 A | 32 A/ 32 A | 32 A / 32 A | |
| Max. short circuit current | 48 A/ 30 A | 48 A/30A | 48 A/ 30 A | 48 A/ 48 A | 48 A / 48 A | |
| No. of independent MPPT inputs /strings per MPPT input | 2/ A:2;B:1 | 2/ A:2;B:1 | 2/ A:2;B:1 | 2/ A:2;B:2 | 2 /A:2;B:2 | |
| OUut(AC) | Rated active power | 12000 W | 13000 W | 15000 W | 17000 W | 20000 W |
| Rated apparent power | 12000 VA | 13000 VA | 15000 VA | 17000 VA | 20000 VA | |
| Max. apparent power | 12000 VA | 13000 VA | 15000 VA | 17000 VA | 20000 VA | |
| AC nominal voltage | 220 V / 380 V230 V / 400 V240 V / 415 V | |||||
| AC voltage range | 160 V - 300 V | |||||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | |||||
| Max. output current | 19.1 A | 20.7 A | 24 A | 27.1 A | 31.9 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | |||||
| Feed-in phases | 3/3-N-PE | |||||
| Harmonic distortion (THD) at rated output | <3% | |||||
| Efic pction | Max. efficiency / European efficiency | 98.6 % / 98.2 % | ||||
| DC Switch | ● | |||||
| Ground fault monitoring / grid monitoring | ●/● | |||||
| DC reverse polarity protection / AC short circuit protection | ●/● | |||||
| All-pole-sensitive residual-current monitoring unit | ● | |||||
| Arc fault circuit interrupter (AFCI) | O | |||||
| Anti-Islanding protection | ● | |||||
| Surge protection | ●/ Type II | |||||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | I/AC: III; DC: II | |||||
| Gen derata | Dimensions (W / H / D) | 503 / 435 / 183 mm | ||||
| Weight | 17.0 kg | |||||
| Operating temperature range | -25℃~60℃ | |||||
| Self-consumption (at night) | <1W | |||||
| Topology | Non-isolated | |||||
| Cooling concept | Active cooling | |||||
| Degree of protection (according to IEC 60529) | IP66 | |||||
| Relative humidity | 0 - 100 % (Non-condensing) | |||||
| Max. operating altitude | 3000 m | |||||
| Features | DC connector | Plug-in connector | ||||
| AC connector | Plug-in connector | |||||
| Mounting type | Wall-mount bracket | |||||
| LED indicators (Status / Fault / Communication) | ● | |||||
| 24/7 monitoring | ● | |||||
| Communication interface | O/0/O(RS4851 / Wi-Fi / LAN) | |||||
| Certificates and approvals (more available on request) | CE, EN50549, IEC62109, IEC62116, IEC61727, IEC61683, IEC60068, IEC61000, AS/NZS4777, C10/C11 | |||||
1 RS485 to approved smart meters for export power control applications
ASW LT-G2 Series
Models:
ASW8K-LT-G2
ASW10K-LT-G2
ASW12K-LT-G2
ASW15K-LT-G2
ASW17K-LT-G2
ASW20K-LT-G2
Easy-to-install
Safe & reliable
User-friendly
Quick and easy-to-install with standard tools
Smart setup, commissioning and monitoring via Solplanet App
Compact wall mount design
Internationally accredited standards
150 % PV array oversizing for higher yields
IP66 rated design for indoor and outdoor use
13A input current, ideal for bifacial and large area PV modules
●Wide MPP voltage range 150V-1000V
ShadeSol - improved generation under non-ideal conditions
| ASW ASW ASW ASW ASW ASWTechnical Datasheet 8K-LT-G2 10K-LT-G2 12K-LT-G2 15K-LT-G2 17K-LT-G2 20K-LT-G2 | |||||||
| (np t(c) | Max. PV array power | 12000 Wp STC | 15000 Wp STC | 18000 Wp STC | 22500 Wp STC | 25500 Wp STC | 30000 Wp STC |
| Max. input voltage | 1100 V | ||||||
| MPP voltage range / rated input voltage | 150 V - 1000 V / 630 V | ||||||
| Min. input voltage | 125 V | ||||||
| Initial. feed-in voltage | 150 V | ||||||
| Max. operating input current | 26 A /13 A | 26 A / 13 A | 26 A / 26 A | 26 A/26 A | 26 A / 26 A | 26 A / 26 A | |
| Max. short circuit current | 40 A / 20 A | 40 A /20 A | 40 A / 40 A | 40 A / 40 A | 40 A / 40 A | 40 A / 40 A | |
| No. of independent MPPT inputs / strings per MPPT input | 2/ A:1;B:1 | 2/ A:1;B:1 | 2/ A:2;B:1 | 2/ A:2;B:1 | 2/ A:2;B:2 | 2/ A:2;B:2 | |
| OUut tu(AC) | Rated active power | 8000 W | 10000 W | 12000 W | 15000 W | 17000 W | 20000 W |
| Rated apparent power | 8000 VA | 10000 VA | 12000 VA | 15000 VA | 17000 VA | 20000 VA | |
| Max. apparent power | 8000 VA | 10000 VA | 12000 VA | 15000 VA | 17000 VA | 20000 VA | |
| AC nominal voltage | 220 V / 380 V230 V / 400 V240 V / 415 V | ||||||
| AC voltage range | 160 V - 300 V | ||||||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | ||||||
| Max. output current | 12.8 A | 16 A | 19.1 A | 24 A | 27.1 A | 31.9 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | ||||||
| Feed-in phases | 3 /3-N-PE | ||||||
| Harmonic distortion (THD) at rated output | <3% | ||||||
| Efitr p pction | Max. efficiency / European efficiency | 98.6 % / 98.2 % | |||||
| DC Switch | ● | ||||||
| Ground fault monitoring / grid monitoring | ●/● | ||||||
| DC reverse polarity protection / AC short circuit protection | ●/● | ||||||
| All-pole-sensitive residual-current monitoring unit | ● | ||||||
| Anti-Islanding protection | ● | ||||||
| Surge protection | ● / Type II | ||||||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | I/ AC: III; DC: II | ||||||
| Gen erdata | Dimensions (W / H / D) | 503 / 435 / 183 mm | |||||
| Weight | 16.0 kg | 17.0 kg | |||||
| Operating temperature range | -25℃~60℃ | ||||||
| Self-consumption (at night) | <1W | ||||||
| Topology | Non-isolated | ||||||
| Cooling concept | Natural convection | Active cooling | |||||
| Degree of protection (according to IEC 60529) | IP66 | ||||||
| Relative humidity | 0- 100 % (Non-condensing) | ||||||
| Max. operating altitude | 3000 m | ||||||
| Features | DC connector | Plug-in connector | |||||
| AC connector | Plug-in connector | ||||||
| Mounting type | Wall-mount bracket | ||||||
| LED indicators (Status / Fault / Communication) | ● | ||||||
| Communication interface | 0/0/O(RS4851 / Wi-Fi / LAN) | ||||||
| Certificates and approvals (more available on request) | CE, EN50549, IEC62109, IEC62116, IEC61727, IEC61683, IEC60068,IEC61000,AS/NZS4777, C10/C11 | ||||||
1 RS485 to approved smart meters for export power control applications
ASW LT-G3 Series
Easy-to-install
Safe & reliable
Quick and easy-to-install with standard tools
Smart setup, commissioning and monitoring via Solplanet App
Compact wall mount design
Internationally accredited standards
150 % PV array oversizing for higher yields
IP66 rated design for indoor and outdoor use
20 A input current, ideal for bifacial and large area PV modules
● 3 MPPTs for flexible PV array design
●Wide MPP voltage range 180V-1000 V
●ShadeSol - improved generation under non-ideal conditions
| Technical Datasheet ASW 25K-LT-G3 ASW 27K-LT-G3 ASW 30K-LT-G3 ASW 33K-LT-G3 ASW 36K-LT-G3 ASW 40K-LT-G3 | |||||||
| (up t(dc) | Max. PV array power | 37500 Wp STC | 40500 Wp STC | 45000 Wp STC | 49500 Wp STC | 54000 Wp STC | 60000 Wp STC |
| Max. input voltage | 1100 V | ||||||
| MPP voltage range / rated input voltage | 180 V - 1000 V / 630 V | ||||||
| Min. input voltage | 160 V | ||||||
| Initial. feed-in voltage | 200 V | ||||||
| Max. operating input current | 32 A / 32 A / 32 A | 32 A / 32 A / 40 A | |||||
| Max. short circuit current | 48 A / 48 A / 48 A | 48 A / 48 A / 60 A | |||||
| No. of independent MPPT inputs /strings per MPPT input | 3 / A:2;B:2;C:2 | 3 / A:2;B:2;C:2 | |||||
| OUut(AC) | Rated active power | 25000 W | 27000 W | 30000 W | 33000 W | 36000 W | 40000 W |
| Rated apparent power | 25000 VA | 27000 VA | 30000 VA | 33000 VA | 36000 VA | 40000 VA | |
| Max. apparent power | 25000 VA | 27000 VA | 30000 VA | 33000 VA | 36000 VA | 40000 VA | |
| AC nominal voltage | 220 V / 380 V230 V / 400 V240 V / 415 V | ||||||
| AC voltage range | 180 V - 305 V / 312 V - 528V | ||||||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | ||||||
| Max. output current | 39.9 A | 43.0 A | 47.8 A | 52.6 A | 57.4 A | 63.8 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | ||||||
| Feed-in phases | 3/3-N-PE | ||||||
| Harmonic distortion (THD) at rated output | <3% | ||||||
| Eii & pction | Max. efficiency / European efficiency | 98.4 % / 98.2 % | |||||
| DC Switch | ● | ||||||
| Ground fault monitoring / grid monitoring | ●/● | ||||||
| DC reverse polarity protection /AC short circuit protection | /0 | ||||||
| All-pole-sensitive residual-current monitoring unit | ● | ||||||
| Arc fault circuit interrupter (AFCI) | O | ||||||
| Anti-islanding Protection | ● | ||||||
| Surge protection | ●/ Type II | ||||||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | I/ AC: III; DC:D | ||||||
| Ge derdata | Dimensions (W / H / D) | 543 / 520 / 235 mm | |||||
| Weight | 29.0 kg | 30.0 kg | |||||
| Operating temperature range | -25°℃~60℃ | ||||||
| Self-consumption (at night) | <1W | ||||||
| Topology | Non-isolated | ||||||
| Cooling concept | Active cooling | ||||||
| Degree of protection (according to IEC 60529) | IP66 | ||||||
| Relative humidity | 0 -100 % (Non-condensing) | ||||||
| Max. operating altitude | 3000 m | ||||||
| Features | DC connector | Plug-in connector | |||||
| AC connector | Plug-in connector | ||||||
| Mounting type | Wall-mount bracket | ||||||
| LED Indicators (Status / Fault / Communication) | ● | ||||||
| 24/7 monitoring | ● | ||||||
| Communication interface | O/O/O(RS4851 / Wi-Fi / LAN) | ||||||
| Certificates and approvals (more available on request) | CE, EN50549,IEC62109, IEC62116,IEC61727,IEC61000,NB/T 32004 | ||||||
1 RS485 to approved smart meters for export power control applications
ASW LT-G3 Series
Easy-to-install
Phoenix Contact for reliable toolfree DC connection
Compact wall mount design
● Fuse free design, lower BOS cost
● Smart setup, commissioning and monitoring via Solplanet App
Higher Yields
150 % PV array oversizing for higher yields
●Up to 5 MPPTs for flexible PV array design
Max. 20 A input current per string, ideal for bifacial and large area PV modules
ShadeSol - improved generation under non-ideal conditions
Safe & reliable
Type II AC & DC surge protection
Integrated DC switches
●IP66 rated design for indoor and outdoor use
| Technical Datasheet ASW45K-LT-G3 ASW50K-LT-G3 ASW60K-LT-G3 | ||||
| (nupt(cl) | Max. PV array power | 67500 Wp STC | 75000 Wp STC | 90000 Wp STC |
| Max. input voltage | 1100 V | |||
| MPP voltage range / rated input voltage | 200 V - 1000 V / 630 V | |||
| Min. input voltage | 200 V | |||
| Initial. feed-in voltage | 250 V | |||
| Max. operating input current | 40 A / 32 A / 32 A / 40 A | 40 A / 32 A / 32 A / 40 A / 32 A | 40 A / 32 A / 32 A / 40 A / 32 A | |
| Max. short circuit current | 60 A / 48 A / 48 A / 60 A | 60 A / 48 A / 48 A / 60 A / 48 A | 60 A / 48 A / 48 A / 60 A / 48 A | |
| No. of independent MPPT inputs / strings per MPPT input | 4/2 | 5/2 | 5/2 | |
| OUut tuAC) | Rated active power | 45000 W | 50000 W | 60000 W |
| Rated apparent power | 45000 VA | 50000 VA | 60000 VA | |
| Max. apparent power | 45000 VA | 50000 VA | 60000 VA | |
| AC nominal voltage | 220 V/ 380 V230 V / 400 V | |||
| AC voltage range | 180 V - 305 V / 312 V - 528 V | |||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | |||
| Max. output current | 75.2 A | 83.6 A | 95.3 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | |||
| Feed-in phases | 3 /3-N-PE | |||
| Harmonic distortion (THD) at rated output | <3% | |||
| Efit pction | Max. efficiency / European efficiency | 98.6 % / 98.3 % | ||
| DC switch | ● | |||
| Ground fault monitoring / grid monitoring | ●/● | |||
| DC reverse polarity protection / AC short circuit protection | ●/0 | |||
| All-pole-sensitive residual-current monitoring unit | ● | |||
| Arc fault circuit interrupter (AFCI) | 0 | |||
| Anti-islanding Protection | ● | |||
| Surge protection | ●/ Type II | |||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | I/ AC: IIl; DC: II | |||
| Sunspec protocol | ● | |||
| Gel rdata | Dimensions (W / H / D) | 670 / 640 / 270 mm | ||
| Weight | 42.5 kg | |||
| Operating temperature range | -25℃~60℃ | |||
| Self-consumption (at night) | <1W | |||
| Topology | Non-isolated | |||
| Cooling concept | Active cooling | |||
| Degree of protection (according to IEC 60529) | IP66 | |||
| Relative humidity | 0 - 100 % (Non-condensing) | |||
| Max. operating altitude | 4000 m | |||
| Features | DC connector | Plug-in connector | ||
| AC connector | OT/DT connector | |||
| Mounting type | Wall-mount bracket | |||
| LED indicators (Status / Fault / Communication) | ● | |||
| 24/7 monitoring | ● | |||
| Communication interface | 0/O/O(RS4851 /Wi-Fi / LAN) | |||
| Certificates and approvals (more available on request) | CE, IEC 62109-1/2,IEC 61727,IEC 62116,IEC61683,G98/G99,VDE4110,VDE4105,EN50549-1/2 | |||
1 RS485 to approved smart meters for export power control applications
ASW LT Series
Safe & reliable
● Type Il AC & DC surge protection
● IP66 rated design for indoor and outdoor use
Fuse free design, lower BOS cost
Higher Yields
ShadeSol - improved generation under non-ideal conditions
● 32A input current each MPPT, ideal for bifacial and large area PV modules
10 MPPTs for flexible PV array design for higher yields.
User-friendly
24/7 monitoring
Smart setup, commissioning and monitoring via Solplanet App
String-level management
| Technical Datasheet ASW 75K-LT ASW 80K-LT ASW 100K-LT ASW 110K-LT | |||||
| (npp t(cl) | Max. PV array power | 112500 Wp STC | 120000 Wp STC | 150000 Wp STC | 165000 Wp STC |
| Max. input voltage | 1100 V | ||||
| MPP voltage range / rated input voltage | 200 V - 1000 V / 630 V | ||||
| Min. input voltage | 200 V | ||||
| Initial. feed-in voltage | 250 V | ||||
| Max. operating input current | 32A | ||||
| Max. short circuit current | 48 A | ||||
| No. of independent MPPT inputs / strings per MPPT input | 8/2 | 8/2 | 10/2 | 10/2 | |
| OUutu(AC) | Rated active power | 75000 W | 80000 W | 100000 W | 110000 W |
| Rated appearant power | 75000 VA | 80000 VA | 100000 VA | 110000 VA | |
| Max. apparent power | 75000 W | 88000 W | 110000 W | 121000 W | |
| AC nominal voltage | 220 V/ 380 V230 V / 400 V | ||||
| AC voltage range | 312 V - 528 V | ||||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | ||||
| AC nominal output current | 114.0 A | 115.8 A | 144.3 A | 158.8 A | |
| Max. output current | 114.0 A | 127.0 A | 158.8 A | 174.7 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | ||||
| Feed-in phases | 3/3-N-PE | ||||
| Harmonic distortion (THD) at rated output | <3% | ||||
| Efhi prction | Max. efficiency / European efficiency | 98.6 % / 98.4 % | |||
| DC switch | ● | ||||
| Ground fault monitoring / grid monitoring | ●/0 | ||||
| DC reverse polarity protection / AC short circuit protection | ● | ||||
| AC Overcurrent Protection | ● | ||||
| DC Surge Protection | Type II | ||||
| AC Surge Protection | Type II | ||||
| Residual Current Monitoring Unit | ● | ||||
| Arc fault circuit interrupter (AFCI) | 0 | ||||
| Anti-islanding Protection | ● | ||||
| Protection class (according to IEC 62109-1) /overvoltage category (according to IEC 62109-1) | I/ AC: III; DC:D: I1 | ||||
| Gel derdata | Dimensions (W / H / D) | 984 / 640 / 330 mm | |||
| Weight | 86.0 kg | ||||
| Operating temperature range | -25℃~60℃ | ||||
| Self-consumption (at night) | <3W | ||||
| Topology | Non-isolated | ||||
| Cooling concept | Active cooling | ||||
| Degree of protection (according to IEC 60529) | IP66 | ||||
| Relative humidity | 0 -100 % (Non-condensing) | ||||
| Max. operating altitude | 4000 m | ||||
| Features | DC connector | Plug-in connector | |||
| AC connector | OT/DT Terminal (Max.240mm²) | ||||
| LED indicators (Status / Fault / Communication) | ● | ||||
| 24/7 moitoring | ● | ||||
| Communication interface | O/O/O(RS4851 /Wi-Fi / LAN) | ||||
| Modbus-Sunspec protocol | ● | ||||
| Certificates and approvals (more available on request) | CE, IEC 62109-1/2,IEC 61727, IEC 62116, IEC61683, EN50549-1/2, VDE4105 | ||||
1 RS485 to approved smart meters for export power control applications
ASW LT Series
Higher Yields
40 A per MPPT, ideal for bifacial and large area PV modules
● ShadeSol - improved generation under non-ideal conditions
● 110 % overload
Smart O&M
String-level management
• Type I+II SPD surge protection for DC & AC
Integrated DC switch
● PID recovery (optional)
User-friendly
●IP66 rated design for indoor and outdoor use
●Intelligent arc fault detection (AFCI) (optional)
Quick and easy-to-install with standard tools
| Technical Datasheet ASW 125K-LT | ||
| I(nupt(dc) | Max. PV array power | 187500 Wp STC |
| Max. input voltage | 1100 V | |
| MPP voltage range / rated input voltage | 200 V - 1000 V / 630 V | |
| Min. input voltage | 200 V | |
| Initial. feed-in voltage | 250 V | |
| Max. operating input current | 10*40 A | |
| Max. short circuit current | 10*50 A | |
| No. of independent MPPT inputs / strings per MPPT input | 10 /2 | |
| OUuttu(AC) | Rated active power | 125000 W |
| Rated apparent power | 125000 VA | |
| Max. apparent power | 137500 VA | |
| AC nominal voltage | 220 V / 380 V230 V / 400 V | |
| AC voltage range | 312 V - 528 V | |
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | |
| Nominal output current | 190.0 A | |
| Max. output current | 209.0 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | |
| Feed-in phases | 3 / 3-N-PE | |
| Harmonic distortion (THD) at rated output | ≤3% | |
| Efictr ction | Max. efficiency / European efficiency | 98.6 % / 98.4 % |
| DC switch | ● | |
| Ground fault monitoring | ● | |
| Grid monitoring | ● | |
| DC reverse polarity protection | ● | |
| AC short-circuit protection | ● | |
| All-pole-sensitive residual-current monitoring unit | ● | |
| Anti-islanding protection | ● | |
| DC surge protection | Type II: ● | |
| Type I+II: O | ||
| AC surge protection | Type I+II: O | |
| Arc Fault circuit interrupter (AFCI) | ● | |
| PID recovery | 。 | |
| Protection class (according to IEC 62109-1) / Overvoltagecategory (according to IEC 62109-1) | 1/ AC: II; DC: I | |
| Sunspec protocol (RTU) | ● | |
| Ge derdata | Dimensions (W / H / D) | 984 / 640 / 330 mm |
| Weight | 87.0 kg | |
| Operating temperature range | -30℃~60℃ | |
| Self-consumption (at night) | <5W | |
| Topology | Non-isolated | |
| Cooling concept | Active cooling | |
| Degree of protection (according to IEC 60529) | IP66 | |
| Relative humidity | 0 - 100 % (Non-condensing) | |
| Max. operating altitude | 4000 m | |
| Features | DC connector | Plug-in connector |
| AC connector | OT/DT connector | |
| LED indicators (Status / Fault / Communication) | ● | |
| Communication interface | 0/O/O(RS4851 /Wi-Fi / LAN) | |
| Certificates and approvals (more available on request) | CE, IEC 62109-1/2,IEC 63027, IEC61727, EN50549 | |
1 RS485 to approved smart meters for export power control applications
ASW LT Series
Higher Yields
● 48 A per MPPT, ideal for bifacial and large area PV modules
● Smart PID recovery for higher yields
● ShadeSol - improved generation under non-ideal conditions
● ABUS to enhance Communciation stability and reduce cable costs (optional)
Smart O&M
Smart I-V Curve tracing for easy diagnostics
String-level management
● Type I+II SPD surge protection for DC & AC with replaceable units
●Integrated DC switch, automatically cuts off the fault
User-friendly
● IP66 and C5 rated design for indoor and outdoor use
DC connector and AC terminal temperature detection
Intelligent arc fault detection (AFCI)
Supports Y-connection
Smart setup, commissioning and monitoring via Solplanet App
| Technical Datasheet ASW 150K-LT | ||
| (nupu tc) | Max. input voltage | 1100 V |
| MPP voltage range / rated input voltage | 200 V - 1000 V / 630 V | |
| Min. input voltage | 200 V | |
| Initial. feed-in voltage | 250 V | |
| Max. operating input current | 8*48 A | |
| Max. short circuit current | 8*60 A | |
| No. of independent MPPT inputs / strings per MPPT input | 8/3 | |
| OUut tutAC) | Rated active power | 150000 W |
| Rated apparent power | 150000 VA | |
| Max. apparent power | 150000 VA | |
| AC nominal voltage | 380 V / 400 V | |
| AC voltage range | 312 V - 528 V | |
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz60 Hz / 55 Hz - 65 Hz | |
| Nominal output current | 227.9 A | |
| Max. output current | 250.7 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | |
| Feed-in phases | 3 / 3-N-PE | |
| Harmonic distortion (THD) at rated output | ≤ 3 % | |
| Efitc p prpection | Max. efficiency / European efficiency | 99.0 % / 98.6 % |
| DC switch | ● | |
| Ground fault monitoring | ●/● | |
| Grid monitoring | ●/● | |
| All-pole-sensitive residual-current monitoring unit | ● | |
| Anti-islanding protection | ● | |
| DC surge protection | Type II (Typel +I O) | |
| AC surge protection | Type II (Typel +II O) | |
| Arc Fault circuit interrupter (AFCI) | ● | |
| PID recovery | o | |
| Protection class (according to IEC 62109-1) / Overvoltagecategory (according to IEC 62109-1) | I/ AC: III; DC: II | |
| Sunspec protocol (RTU) | ● | |
| Ge derata | Dimensions (W / H / D) | 1010 / 757 / 362 mm |
| Weight | 101.0 kg | |
| Operating temperature range | -30°℃~60°℃ | |
| Self-consumption (at night) | <3W | |
| Topology | Non-isolated | |
| Cooling concept | Active cooling | |
| Degree of protection (according to IEC 60529) | IP66 | |
| Relative humidity | 0 - 100 % (Non-condensing) | |
| Max. operating altitude | 4000 m | |
| Features | DC connector | Plug-in connector |
| AC connector | OT/DT connector | |
| LED indicators (Status / Fault / Communication) | ● | |
| Communication interface | ●/●/0(RS4851 /Wi-Fi / ABUS) | |
| Certificates and approvals (more available on request) | CE, IEC 62109-1/2,IEC 63027, IEC 61727, EN 50549, IEC 62116, IEC 61683, IEC 61000 | |
1 RS485 to approved smart meters for export power control applications
ASW HT Series
Safe & reliable
Smart O&M
ABUS to enhance communciation stability and reduce cable costs
• Designed to operate in challenging global environmental conditions
● DC connector and AC terminal temperature detection
● Smart DC connector disconnection
●High operation capability in weak grid
Maximizing yield by leading conversion efficiency > 99 %
● Compatible with max. 500mm² AC cables
● Night and day time reactive power control
75A per MPPT, compatible with high current PV modules
● Secured and reliable remote firmware upgrade simplifying longterm operation
Smart Il-V Curve tracing for easy diagnostics
Smart self-cleaning fans
Anti-PID solution to mitigate PV module degradation
| Technical Datasheet ASW250K-HT ASW333K-HT ASW350K-HT ASW360K-HT | |||||
| (nt tcl) | Max. input voltage | 1500 V | |||
| MPP voltage range / rated input voltage | 500 V - 1500 V / 1080 V | ||||
| Min. input voltage | 500 V | ||||
| Start up input voltage | 550 V | ||||
| Max. operating input current per MPP | 75 A | ||||
| Max. short circuit current per MPP | 113 A | ||||
| No. of independent MPPT inputs / strings per MPPT input | 5/5 | 6/5 | |||
| OUutu(AC) | AC output power | 250000 VA @ 50 °℃ | 333000 VA @ 40 °℃ | 352000 VA @ 40 °℃ | 363000 VA @ 40 ℃ |
| 325000 VA @ 50 °℃ | 328000 VA @ 50 °℃ | ||||
| AC nominal voltage | 800 V | ||||
| AC voltage range | 640 V - 920 V | ||||
| AC grid frequency / range | 50 Hz / 45 Hz - 55 Hz | ||||
| 60 Hz / 55 Hz - 65 Hz | |||||
| Max. output current | 198.5 A | 240.3 A | 254.0 A | 262.0 A | |
| Adjustable power factor range | 0.8 leading - 0.8 lagging | ||||
| Feed-in phases | 3/3-PE | ||||
| THD | <3% | ||||
| Ccincy出 | Max. efficiency / European efficiency | 99.01 % / 98.8 % | |||
| Eie & pction | Smart DC switch | ● | |||
| AC / DC temperature detection | |||||
| Anti-islanding protection | |||||
| AC overcurrent protection | |||||
| DC reverse-polarity protection | ● | ||||
| AC short circuit protection | ● | ||||
| PV string monitoring | ● | ||||
| DC surge protection | Type II | ||||
| AC surge protection | Type II | ||||
| Residual Current Monitoring Unit (RCMU) | ● | ||||
| Ground fault monitoring | ● | ||||
| Grid monitoring | ● | ||||
| Anti-PID | o | ||||
| Gell data | Dimensions (W / H / D) | 1,158 / 760 / 382 mm | |||
| Weight | ≤ 116.0 kg | ≤ 117.0 kg | |||
| Operating temperature range | -30℃~60℃ | ||||
| Self-consumption (at night) | <5W | ||||
| Topology | Non-isolated | ||||
| Cooling concept | Smart forced cooling | ||||
| Protection degree | IP66 | ||||
| Relative humidity | 0 - 100% (Non-condensing) | ||||
| Max. operating altitude | 5000 m (> 4000 m with derating) | ||||
| Features | DC connector | DC Plug-in connector | |||
| AC connector | OT / DT Terminal (Max.500mm²) | ||||
| Display | LED, Bluetooth + App | ||||
| USB | ● | ||||
| Communication | RS485 / ABUS | ||||
| Com-pliance | Certificates and approvals (more available on request) | IEC 62109-1/2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50549-2 | |||
ASW MT Series
High Integration
● Standard container design include LV panel, transformer, RMU for easy transportation
No internal cabling needed onsite, preassembled in the factory
Flexible
Compatible with ASW-HT series inverter
●Up to 9 MW block design
Easy O&M
● Modular design, easy to locate and replace faults
LV panel, transformer and RMU monitored online, remotely controls LV panel and RMU
Reliable
● Components compliance with requirements of standards
Excellent protection design ensures working in harsh enviroments
| Technical Datasheet ASW3000K-MT ASW6000K-MT ASW9000K-MTInverter model ASW360K-HT | ||||
| ACTransmer | power | 3,630 kVA @ 30 °C3,300 kVA @ 40 °C | 7260 kVA @ 30 °C6600 kVA @ 40 °C | 10164 kVA @ 30 °℃9240 kVA @ 40 °C |
| LV / MV voltage | 0.8 kV / 10-35 kV | 0.8-0.8 kV / 10-35 kV | ||
| Frequency | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | |
| Transformer type | Oil-immersed | Oil-immersed | Oil-immersed | |
| Transformer cooling type | ONAN | ONAN | ONAN | |
| Transformer tappings | ± 2 × 2.5 % | ± 2 x 2.5 % | ± 2 x 2.5 % | |
| Transformer oil type | Mineral oil (PCB free) | Mineral oil (PCB free) | Mineral oil (PCB free) | |
| Transformer vector group | Dy11 | Dy11-y11 | Dy11-y11 | |
| Winding material | AL/AL | AL/AL | AL/AL | |
| Insulation class | A | A | A | |
| Transformer efficiency | ≥ 99 % | ≥ 99 % | ≥ 99 % | |
| LVROOM | Max. LV AC inputs | 10 | 20 | 28 |
| Rated input voltage | 800 V | 800 V | 800 V | |
| LV main switches | ACB (3200 A, 1 pcs) | ACB (3200 A, 2 x 1 pcs) | ACB (4000 A, 2 x 1 pcs) | |
| LV AC inputs switches | MCCB (400 A, 10 pcs) | MCCB (400 A, 2 x 10 pcs) | MCCB (400 A, 2 x 14 pcs) | |
| MV OM | RMU type | SF6 Gas insulated | SF6 Gas insulated | SF6 Gas insulated |
| Rated output voltage | 10 / 35 kV | 10 / 35 kV | 10 / 35 kV | |
| Qty. of feeder | 3 feeders | 3 feeders | 3 feeders | |
| Internal arcing fault | IAC A 20 kA 1s | IAC A 20 kA 1s | IAC A 20 kA 1s | |
| Auxiliary transformer | Dry type transformer, 5 kVA,400 Vac | Dry type transformer, 5 kVA,400 Vac | Dry type transformer, 5 kVA,400 Vac | |
| UPS | 1kVA | 1kVA | 1kVA | |
| Protcton | Transformer detection & protection | Oil level, oil temperature, oilpressure; buchholz | Oil level, oil temperature, oilpressure; buchholz | Oil level, oil temperature, oilpressure; buchholz |
| Protection degree of MV & LV room | IP54 | IP54 | IP54 | |
| MV relay protection | 50 / 51, 50N / 51N | 50 / 51, 50N / 51N | 50 / 51, 50N / 51N | |
| LV overvoltage protection | Type I+II | Type I+II | Type I+II | |
| Anti-rodent protection | : C4-HO: C5-M | : C4-HO: C5-M | : C4-HO: C5-M | |
| GenlalData | Dimensions (W / D / H) | 6,058 / 2,438 / 2,896 mm | 6,058 / 2,438 / 2,896 mm | 6,058 / 2,438 / 2,896 mm |
| Weight | <19t | < 23t | <27t | |
| Operating temperature range | -25°℃~60°℃ | -25°℃~60°℃ | -25°℃~60°℃ | |
| Relative humidity | 0 - 100 % (Non-condensing) | 0 - 100 % (Non-condensing) | 0 - 100 % (Non-condensing) | |
| Max. operating altitude | : 2000 mO: > 2000 m | : 2000 mO: > 2000 m | : 2000 mO: > 2000 m | |
| LV & MV room cooling | Smart cooling | Smart cooling | Smart cooling | |
| Cominntionnterace | Modbus-RTU | ● | ● | ● |
| Ethernet | ● | ● | ● | |
| Optical fiber | 0 | 0 | 0 | |
| Features | MV surge arrester for transformer | o | 0 | 0 |
| 2 kVA UPS | 0 | o | 0 | |
| Auxiliary transformer 40 kVA | 0 | o | 0 | |
| Operating temperature range | -30 °℃~60°C (Optional) | -30 °C~ 60°C (Optional) | -30 °C~ 60°C (Optional) | |
| Copli-ance | Certificates and approvals (more available on request) | IEC 62271-202, EN 50588-1,IEC 60076, IEC 62271-200, IEC61439-1/-2 | IEC 62271-202, EN 50588-1,IEC 60076, IEC 62271-200, IEC61439-1/-2 | IEC 62271-202, EN 50588-1,IEC 60076, IEC 62271-200, IEC61439-1/-2 |
Perfect for home & small commercial and industrial applications
ASW H-S2 SERIES
ASW3000 /3680 /4000 /
5000 /6000H-S2
ASW SH SERIES ASW008K / 010K-SH
ASW H-T2 SERIES ASW05k / 06k / 08k /10k / 12kH-T2
ASW H-T3 SERIESASW08k /10k / 12kH-T3
ASW H-T2-DG SERIES ASW05k / 06k / 08k / 10k / 12kH-T2-DG
ASW H-T3-DG SERIES ASW08k /10k/12k /15kH-T3
ASW TH SERIES ASW015K /020K /025K /29.9K /030K-TH
ASW A-S SERIES
ASW0600/1250A-SASW0600/2500A-S
ASW0800/1250A-SASW0800/2500A-S
ASW1000/1250A-SASW1000/2500A-S
ASW H-S2 Series
Quick and easy-to-install with standard tools
● Smart setup, commissioning and monitoring via Solplanet App
Compact wall mount design
Smart energy management
● UPS capability - power during blackouts
● IP66 rated design for indoor and outdoor use
● User friendly App interface
ShadeSol - improved generation under non-ideal conditions
| Technical Datasheet ASW3000H-S2 ASW3680H-S2 ASW4000H-S2 ASW5000H-S2 ASW6000H-S2 | ||||||
| PVput | Max. PV array power | 5500 Wp STC | 6180 Wp STC | 6500 Wp STC | 7500 Wp STC | 9000 Wp STC |
| Max. input voltage | 550 V | |||||
| MPP voltage range / rated input voltage | 40 V - 530 V / 380 V | |||||
| Min. input voltage / start voltage | 40 V / 50 V | |||||
| No. of independent MPPT trackers / strings per MPPT input | 2/1 | |||||
| Max. input current per MPP tracker | 16 A | |||||
| Max. short-circuit current per MPP tracker | 20 A | |||||
| Batryttput | Nominal battery voltage | 48 V | ||||
| Battery voltage range | 40 V- 60 V | |||||
| Max. charge / discharge power | 5000 W / 5000 W | |||||
| Max. charge / discharge current | 100 A / 100A | |||||
| Battery type | LiFePO4 | |||||
| Compatible Battery | Aiswei Ai-LB series³ | |||||
| ACctu put | AC voltage range / Nominal AC voltage | 180 V - 280 V / 220, 230 V | ||||
| Rated AC grid frequency | 50 Hz / 60 Hz | |||||
| AC grid frequency range | 45 Hz -55 Hz / 55 Hz-65 Hz | |||||
| Rated active power | 3000 W | 3680 W | 4000 W | 5000 W1 | 6000 W | |
| Rated apparent power | 3000 VA | 3680 VA | 4000 VA | 5000 VA1 | 6000 VA | |
| Max. apparent power | 3000 VA | 3680 VA | 4000 VA | 5000 VA 1 | 6000 VA | |
| Rated grid output Current (@230V) | 13.1 A | 16 A | 17.4 A | 21.7 A ² | 26.1 A | |
| Max. grid output current | 13.6 A | 16 A | 18.2 A | 22.7 A 2 | 27.3 A | |
| Harmonics THDi (@ Nominal power) | <3% | |||||
| ACu put | Rated grid voltage | 220 V / 230 V | ||||
| Rated apparent power | 6000 VA | |||||
| Max. input apparent power from grid | 6000 VA | |||||
| Rated input current from grid | 26.1 A | |||||
| Max. input current from grid | 27.3 A | |||||
| Nominal output voltage | 220 V /230 V | |||||
| Nominal output frequency | 50 Hz / 60 Hz | |||||
| Rated apparent power | 5000 VA | |||||
| EPS put | Max. output apparent power | 5000 VA | ||||
| Peak output apparent power | 7500 VA, 10s | |||||
| Rated Current (@230V) | 21.7 A | |||||
| Max. output current | 21.7 A | |||||
| Max. switch time | ≤ 10 ms | |||||
| Output THDi (@ Linear load) | <3% | |||||
| 号 | MPPT efficiency | 99.9 % | ||||
| European efficiency / Max. efficiency | 97.0 % / 97.6 % | |||||
| Max. battery to load efficiency | 94.7 % | |||||
| Safectr ption | DC-side disconnection device | ● | ||||
| PV string-/ Battery input reverse polarity protection | ●/● | |||||
| All-pole sensitive residual current monitoring unit | ||||||
| Anti-islanding protection | ||||||
| Ground fault protection | ||||||
| AC output over current / short circuit current protection | 0/0 | |||||
| AC over voltage protection | ● | |||||
| Protection class (as per IEC 62109-1) /overvoltage category (as per IEC 62109-1) | I/ AC: III; DC: II | |||||
| Arc fault circuit interrupter (AFCI) | O⁴ | |||||
| Genl draata | Power factor at rated power / adjustable displacement | ≥ 0.99 / 0.8 leading - 0.8 lagging | ||||
| Dimensions (W / D / H) | 483 / 193.5 / 455 mm | |||||
| Device weight | 25.0 kg | |||||
| Operating temperature range | -25℃~60℃ | |||||
| Noise emissions (typical) | 30 dB | |||||
| Standby consumption | <10 W | |||||
| Cooling concept | Natural convection | |||||
| Degree of protection (as per IEC 60529) | IP66 | |||||
| Climatic category (according to IEC 60721-3-4) | 4K4H | |||||
| Relative humidity | 100 % | |||||
| Max. operating altitude | 4000 m (> 3000 m derating) | |||||
| Feattues | HMI | LED, App | ||||
| Communication with BMS | CAN | |||||
| Communication with meter | RS485 | |||||
| Communication with portal | Wi-Fi stick | |||||
| Other communication | DRM | |||||
| Integrated power control / Zero export control | ●/● | |||||
1 For VDE-AR-N4105,Smax=Sn=4600VA,Pn=4600W 2For AS/NZS4777.2,lac max=21.7A 3Including but not limited to the listed models, please check the website@solplanet for more compatible models
ASW SH Series
• 3 independent MPPTs for flexible and optimized large PV array design
● Max. 20 A input current per MPPT, ideal for bifacial and large area PV modules
● Up to 200% PV array oversizing for higher energy yields
ShadeSol shadow management
● UPS-level switching time < 10 ms
● IP66 rated design for indoor and outdoor use
● Up to 200 % power output for 10s during power outages
Multi-source design for black start, integrating PV, battery, and generator
Expandable up to 30 kW in on-grid and off-grid mode
● Compatible with both lead-acid and lithium batteries
Smart setup, commissioning and monitoring via Solplanet App
| Technical | Datasheet | ASW008K-SH | ASW010K-SH |
| PVput | Max. PV array power | 16000 Wp | 20000 Wp |
| Max. input voltage | 550 V | ||
| MPP voltage range / rated input voltage | 40 V - 530 V / 380 V | ||
| Min. input voltage / start voltage | 40 V/50 V | ||
| No. of independent MPPT trackers / strings per MPPT input | 3/ | 1 | |
| Max. input current / Max. power per MPP tracker | 20 A / 10000 W | 20 A/ 10000 W | |
| Max. short-circuit current per MPP tracker | 25 A | ||
| Bateryupdu! | Battery voltage range | 40 V - 60V | |
| Max. charge / discharge power | 8000 W | 10000 W | |
| Max. charge / discharge current | 190 A | 210 A | |
| Battery type | LiFePO4 / Lead-acid | ||
| ACctuo put | AC voltage range / Nominal AC voltage | 154 V - 276 V /220 V / 230 V / 240 V L/N | |
| Rated AC grid frequency | 50 Hz / 60 Hz | ||
| AC grid frequency range | 45 Hz - 55 Hz / | 55 Hz - 65 Hz | |
| Rated apparent power | 8000 VA | 10000 VA | |
| Max. apparent power | 8000 VA | 10000 VA | |
| Rated grid output current (@230 V) | 34.8 A | 43.5 A | |
| Max. grid output current (@230 V) | 38.3 A | 47.8 A | |
| Harmonic distortion (THD) at rated output | < 3 % (of nominal power) | ||
| Power factor at rated power / adjustable range | 1 / 0.8 leading - 0.8 lagging | ||
| ACu put | Nominal AC voltage | 220 V / 230 V / 240 V L/N | |
| Rated grid frequency | 50 Hz / | 60 Hz | |
| Max. input power from grid | 16000 W | 18000 W | |
| Max. input current from grid | 69.6 A | 78.3 A | |
| EP put | Nominal AC voltage | 220 V / 230 V / 240 V L/N | |
| Nominal output frequency | 50 Hz / 60 Hz | ||
| Rated apparent power | 8000 VA | 10000 VA | |
| Peak output apparent power (off-grid up to 10s) | 16000 VA | 20000 VA | |
| Rated current (@230 V) | 34.8 A | 43.5 A | |
| Max. current (@230 V, continuous on-grid / off-grid) | 38.3 A | 47.8 A | |
| Max. switch time | < 10 ms | ||
| Output THDv (@ Linear load) | 2% | ||
| Geeratorsde | Max. intput apparent power | 8000 VA | 10000 VA |
| Max. charge / discharge power | 8000 VA | 10000 VA | |
| Max. input current | 36.4 A | 45.5 A | |
| Rated AC voltage | 220 V / 230 V / 240 V L/N | ||
| Rated AC frequency | 50 Hz / 60 Hz | ||
| Ciency山 | MPPT efficiency | 99.9 % | |
| European efficiency / Max. efficiency | 97.0 % / 97.6 % | ||
| Ssarfttrt ptction | Surge protection | / Type II | |
| Insulation resistance detection | ● | ||
| PV string input reverse polarity protection | ● | ||
| Ground fault monitoring | ● | ||
| Residual current monitoring unit | 0 | ||
| AC short circuit protection | |||
| Anti-islanding protection | ● | ||
| Gen erdata | Dimensions (W / D / H) | 484 / 230 / 679 mm | |
| Weight | 34.5 kg | ||
| Operating temperature range | -25°℃~60°℃ | ||
| Cooling concept | Smart cooling | ||
| Degree of protection (as per IEC 60529) | IP66 | ||
| Relative humidity | 100 % | ||
| Max. operating altitude | 3000 m | ||
| BMSFeatures | HMI | LED, App | |
| interface | CAN | ||
| Communication interfaces | Dongle: Wi-Fi (2.4 GHz) / LAN (100 Mbps)Inverter: RS485 (ModBus RTU), LAN (100Mbps, ModBus TCP only) | ||
| Digital output (dry contact) / No. of outputs | ● /2 | ||
| Digital input (dry contact) / No. of inputs | ●/6 | ||
| Integrated power control / export power control | ●/0 | ||
ASW H-T2 Series
Models :
ASW05kH-T2
ASW06kH-T2
ASW08kH-T2
ASW10kH-T2
ASW12kH-T2
Easy-to-install
Quick and easy-to-install with standard tools
● Compact wall mount design
Simple battery and smart meter interfaces for quick and secure installation
Safe & reliable
● Up to 150 % PV array oversizing for higher yields
● Available with or without asymmetrical power output 1
● UPS level switching time < 10 ms
●IP66 rated design for indoor and outdoor use
Arc fault circuit interrupter (AFCl) ²
ShadeSol shadow management
User-friendly
Smart setup, commissioning and monitoring via Solplanet App
• Intelligent operation modes and smart battery management for DOD / Time of Use / Power setting
Max. 20 A input current, ideal for bifacial and large PV modules
Supporting parallel for on-grid and off-grid operation
| Technical Datasheet ASW05kH-T2 ASW06kH-T2 ASW08kH-T2 ASW10kH-T2 ASW12kH-T2 | ||||||
| PVyuuput | Max. PV array power | 7500 Wp | 9000 Wp | 12000 Wp | 15000 Wp | 18000 Wp |
| Max. input voltage | 1100 V5 | |||||
| MPP voltage range / rated input voltage | 150 V - 950 V / 630 V | 200 V - 950 V / 630 V ³ | ||||
| Min. input voltage / start voltage | 60 V / 180 V | |||||
| No. of independent MPPT trackers / strings per MPPT input | 2/1 | |||||
| Max. input current / Max. power per MPP tracker | 20 A / 7500 W | 20 A / 9000 W | 20 A / 10000 W | 20 A / 10000 W | 20 A / 10000 W | |
| Max. short-circuit current per MPP tracker | 30 A | |||||
| Batryuput | Battery voltage range | 120 V - 600 V⁵ | ||||
| Max. charge / discharge power | 5000 W | 6000 W | 8000 W | 10000 W | 12000 W | |
| Max. charge / discharge current | 30 A5 | |||||
| Battery type | LiFePO4 | |||||
| ACuiput | Rated grid voltage | 3/N/PE, 220 V / 380 V; 230 V / 400 V; 240 V / 415 V | ||||
| Rated grid frequency | 50 Hz / 60 Hz | |||||
| Max. input power from grid | 10000 W | 12000 W | 16000 W | 20000 W | 24000 W | |
| Max. input current from grid | 14.5 A | 17.4 A | 23.2 A | 29.0 A | 34.8 A | |
| ACctt put | AC voltage range / Nominal AC voltage | 270 V - 480 V / 3/N/PE, 220 V / 380 V; 230 V / 400 V; 240 V / 415 V | ||||
| Rated AC grid frequency | 50 Hz / 60 Hz | |||||
| AC grid frequency range | 45 Hz - 55 Hz / 55 Hz - 65 Hz | |||||
| Rated apparent power | 5000 VA | 6000 VA | 8000 VA | 10000 VA | 12000 VA | |
| Max. apparent power | 5000 VA | 6000 VA | 8000 VA | 10000 VA | 12000 VA | |
| Rated grid output current (@400 V) | 7.3 A | 8.7 A | 11.6 A | 14.5 A | 17.4 A | |
| Max. grid output current (@400 V) | 8.0 A | 9.6 A | 12.8 A | 16.0 A | 19.2 A | |
| Power factor at rated power / adjustable range | 1 / 0.8 leading - 0.8 lagging | |||||
| Harmonics THDi | < 3 % (of nominal power) | |||||
| EPS put | Nominal output voltage | 3/N/PE, 220 V / 380 V; 230 V / 400 V; 240 V / 415 V | ||||
| Nominal output frequency | 50 Hz / 60 Hz | |||||
| Rated apparent power | 5000 VA | 6000 VA | 8000 VA | 10000 VA | 12000 VA | |
| Rated current (@400 V) | 7.3 A | 8.7 A | 11.6 A | 14.5 A | 17.4 A | |
| Max. current (@400 V, continuous on-grid / off-grid) | 14.5 A / 7.3 A | 17.4 A / 8.7 A | 23.2 A / 11.6 A | 29.0 A / 14.5 A | 34.8 A / 17.4 A | |
| Max. power on each phase (@400 V, continuous on-grid / off-grid) | 3333 W / 1667 W | 4000 W / 2000 W | 5333 W / 2667 W | 6667 W / 3333 W | 8000 W / 4000 W | |
| Peak output apparent power (@400 V, continuous on-grid / off-grid up to 10s) | 10000 VA / 10000 VA | 12000 VA / 12000 VA | 16000 VA / 16000 VA | 20000 VA / 20000 VA | 24000 VA / 24000 VA | |
| Max. switch time | < 10 ms | |||||
| Output THDv (@Linear load) | 2% | |||||
| MPPT efficiency | 99.9 % | |||||
| European efficiency / Max. efficiency | 97.2 % / 98.0 % | 97.5 % / 98.2 % | 97.9 % / 98.4 % | |||
| Safetetor ptction | DC surge protection (Type Il, according to EN/IEC 61643-11) | |||||
| Insulation resistance detection | ||||||
| PV string input reverse polarity protection | ||||||
| Battery input reverse polarity protection | ||||||
| Ground fault monitoring | O | |||||
| Residual current monitoring unit | ||||||
| AC short circuit protection | ||||||
| Anti-islanding protection | ● | |||||
| Arc fault circuit interrupter (AFCI) | O2 | |||||
| Ge deraata | Dimensions (W / D / H) | 545 / 205 / 465 mm | ||||
| Weight | 24.5 kg | |||||
| Operating temperature range | -25°℃~60°℃ | |||||
| Cooling concept | Natural convection | |||||
| Noise emission | < 35 dB | |||||
| Degree of protection (as per IEC 60529) | IP66 | |||||
| Relative humidity | 100 % | |||||
| Max. operating altitude | 4000 m | |||||
| Feattures | HMI | LED, App | ||||
| BMS interface | CAN | |||||
| Smart meter interface | RS485 | |||||
| Communication interfaces | Dongle: Wi-Fi (2.4 GHz) / LAN (100 Mbps)Inverter: RS485 (ModBus RTU), LAN (100 Mbps, ModBus TCP only) ⁴ | |||||
| Digital output (dry contact) / No. of outputs | ●/2 | |||||
| Digital input (dry contact) / No. of inputs | ● /4 | |||||
| Integrated power control / export power control | ●/● | |||||
| Certificates (more available upon request) | AS / NZS 4777.2, TOR Stromerzeugungsanlagen Typ A, C10 / 11, TR 3.3.1, FD C11 - 519 - 11, EN 50549 - 1,EN 61000 - 6 - 1, EN 61000-6-2, EN 61000 - 6 - 3, EN 61000 - 6 - 4, VDE-AR-N 4105, IEC 60068 - 2 - x, IEC 61683.IEC 61727, IEC 62116, IEC 63027, NTS Type A. RD 647, UNE 217001, UNE 217002, NA / EEA-NE7, G99 - 1, PORTARIA Nº 140 | |||||
1 Asymmetrical power output functionality released in August 2024, please confirm version with Solplanet's sales staff before purchase.
2AFCl functionality released in April 2025, please confirm version with Solplanet's sales staff before purchase.
3 The latest optimised platform design supports MPP voltage range at 150 V - 950 V, pending subsequent certificate updates.
4Modbus TCP functionality released in April 2025, please confirm version with Solplanet's sales staff before purchase.
5 When connecting to Solplanet's Ai-HB G2 Series batteries (with only 5 kWh, i.e. two modules), limitations as below apply:
1. The maximum open circuit voltage of PV shall not exceed 750 V; 2.The battery nominal voltage range is reduced to 102.4 V for the particular operation; 3.The maximum charging and discharging current depends on the operating point and is within the range greater than 25 A, less than 30 A.
ASW H-T3 Series
Models: ASW08kH-T3 ASW10kH-T3 ASW12kH-T3
Easy-to-install
Quick and easy-to-install with standard tools
● Compact wall mount design
● Simple battery and smart meter interfaces for quick and secure installation
Safe & reliable
● Up to 150 % PV array oversizing for higher yields
•Available with or without asymmetrical power output 1
● UPS level switching time < 10 ms
●IP66 rated design for indoor and outdoor use
Arc fault circuit interrupter (AFCl) ²
● ShadeSol shadow management
User-friendly
3 independent MPPTs for flexible and higher kWp PV array design
Smart setup, commissioning and monitoring via Solplanet App
• Intelligent operation modes and smart battery management for DOD / Time of Use / Power setting
Max. 16 A input current, ideal for bifacial and large PV modules
● Supporting parallel for on-grid and off-grid operation