| MODEL | POWER | DIMENSION(UNIT:mm) | WEIGHT (kg) | |||||
| kW | HP | B1 | B2 | B1+B2 | D1 | D2 | ||
| XRF 45-1 | 5.5 | 7.5 | 632 | 410 | 1042 | 250 | 210 | 96 |
| XRF 45-2-2B | 7.5 | 10 | 712 | 410 | 1122 | 250 | 210 | 99 |
| XRF45-2-2A | 7.5 | 10 | 712 | 410 | 1122 | 250 | 210 | 99 |
| XRF 45-2-2 | 11 | 15 | 742 | 528 | 1270 | 330 | 315 | 153 |
| XRF 45-2 | 11 | 15 | 742 | 528 | 1270 | 330 | 315 | 153 |
| XRF45-3-3A | 15 | 20 | 822 | 528 | 1350 | 330 | 315 | 164 |
| XRF 45-3-3 | 15 | 20 | 822 | 528 | 1350 | 330 | 315 | 164 |
| XRF 45-3-2 | 15 | 20 | 822 | 528 | 1350 | 330 | 315 | 164 |
| XRF 45-3-1 | 15 | 20 | 822 | 528 | 1350 | 330 | 315 | 165 |
| XRF 45-3 | 18.5 | 25 | 822 | 558 | 1380 | 330 | 315 | 181 |
| XRF 45-4-3 | 18.5 | 25 | 902 | 558 | 1460 | 330 | 315 | 185 |
| XRF45-4 | 22 | 30 | 902 | 581 | 1483 | 380 | 340 | 220 |
| XRF 45-5-2 | 30 | 40 | 982 | 619 | 1601 | 380 | 340 | 272 |
| XRF45-5 | 30 | 40 | 982 | 619 | 1601 | 380 | 340 | 272 |
| XRF 45-6-3 | 30 | 40 | 1062 | 619 | 1681 | 380 | 340 | 275 |
| XRF45-6 | 37 | 50 | 1062 | 735 | 1797 | 421 | 360 | 292 |
| XRF 45-7 | 37 | 50 | 1142 | 735 | 1877 | 421 | 360 | 295 |
PerformanceCurve
Outline Drawing
Dimension/Weight
| MODEL | POWER | DIMENSION(UNIT:mm) | WEIGHT (kg) | |||||
| kW | HP | B1 | B2 | B1+B2 | D1 | D2 | ||
| XRF 64-1A | 7.5 | 10 | 634 | 410 | 1044 | 250 | 210 | 115 |
| XRF 64-1 | 7.5 | 10 | 634 | 410 | 1044 | 250 | 210 | 115 |
| 11 | 15 | 664 | 528 | 1192 | 330 | 315 | 178 | |
| XRF 64-2-2B | 11 | 15 | 747 | 528 | 1275 | 330 | 315 | 181 |
| XRF64-2-2A | 11 | 15 | 747 | 528 | 1275 | 330 | 315 | 181 |
| XRF 64-2-2 | 15 | 20 | 747 | 528 | 1275 | 330 | 315 | 181 |
| XRF64-2-1 | 15 | 20 | 747 | 528 | 1275 | 330 | 315 | 183 |
| XRF64-2 | 18.5 | 25 | 747 | 558 | 1305 | 330 | 315 | 199 |
| XRF64-3-3 | 18.5 | 25 | 829 | 558 | 1387 | 330 | 315 | 202 |
| XRF 64-3-2 | 22 | 30 | 829 | 581 | 1410 | 380 | 340 | 237 |
| XRF64-3-1A | 22 | 30 | 829 | 581 | 1410 | 380 | 340 | 237 |
| XRF 64-3-1 | 30 | 40 | 829 | 619 | 1448 | 380 | 340 | 290 |
| XRF64-3 | 30 | 40 | 829 | 619 | 1448 | 380 | 340 | 292 |
| XRF 64-4-2 | 30 | 40 | 912 | 619 | 1531 | 380 | 340 | 295 |
| XRF64-4-1A | 30 | 40 | 912 | 619 | 1531 | 380 | 340 | 295 |
| XRF 64-4 | 37 | 50 | 912 | 735 | 1647 | 421 | 360 | 315 |
| XRF64-5-2 | 37 | 50 | 994 | 735 | 1729 | 421 | 360 | 316 |
| XRF 64-5 | 45 | 60 | 994 | 735 | 1729 | 421 | 360 | 375 |
| XRF 64-6-2 | 45 | 60 | 1077 | 735 | 1812 | 421 | 360 | 378 |
PerformanceCurve
Outline Drawing
Dimension/Weight
| MODEL | POWER | WEIGHT | ||||||
| kW | HP | B1 | DIMENSION(UNIT:mm) | D1 | D2 | |||
| XRF95-1A | 11 | 15 | 701 | 528 | 1229 | 330 | 315 | 189 |
| XRF95-1 | 15 | 20 | 701 | 528 | 1229 | 330 | 315 | 189 |
| XRF 95-2-2A | 15 | 20 | 806 | 528 | 1334 | 330 | 315 | 193 |
| XRF95-2-2 | 18.5 | 25 | 806 | 558 | 1364 | 330 | 315 | 210 |
| XRF95-2-1A | 22 | 30 | 806 | 581 | 1387 | 380 | 340 | 224 |
| XRF95-2-1 | 22 | 30 | 806 | 581 | 1387 | 380 | 340 | 225 |
| XRF95-2 | 30 | 40 | 806 | 619 | 1425 | 380 | 340 | 345 |
| XRF95-3-2 | 30 | 40 | 910 | 619 | 1529 | 380 | 340 | 350 |
| XRF95-3-1A | 37 | 50 | 910 | 735 | 1645 | 421 | 360 | 374 |
| XRF95-3-1 | 37 | 50 | 910 | 735 | 1645 | 421 | 360 | 375 |
| XRF95-3A | 37 | 50 | 910 | 735 | 1645 | 421 | 360 | 376 |
| XRF95-3 | 37 | 50 | 910 | 735 | 1645 | 421 | 360 | 376 |
| XRF 95-4-3 | 37 | 50 | 1015 | 735 | 1750 | 421 | 360 | 380 |
| XRF95-4-2 | 45 | 60 | 1015 | 735 | 1750 | 421 | 360 | 462 |
| XRF 95-4-1 | 55 | 75 | 1035 | 760 | 1795 | 463 | 385 | 540 |
| XRF95-4 | 55 | 75 | 1035 | 760 | 1795 | 463 | 385 | 540 |
| XRF95-5-2 | 55 | 75 | 1139 | 760 | 1899 | 463 | 385 | 552 |
| XRF95-5-1 | 55 | 75 | 1139 | 760 | 1899 | 463 | 385 | 554 |
| XRF 95-5 | 75 | 100 | 1139 | 910 | 2049 | 505 | 405 | 686 |
| XRF95-6 | 75 | 100 | 1244 | 910 | 2154 | 505 | 405 | 690 |
PerformanceCurve
Outline Drawing
Dimension/Weight
| MODEL | POWER | WEIGHT | ||||||
| kW | HP | B1 | DIMENSION(UNIT:mm) | D1 | D2 | |||
| XRF 125-1-1A | 11 | 15 | 783 | 528 | 1311 | 330 | 315 | 265 |
| XRF125-1A | 15 | 20 | 783 | 528 | 1311 | 330 | 315 | 265 |
| XRF125-1 | 18.5 | 25 | 783 | 558 | 1341 | 330 | 315 | 282 |
| XRF125-2-2B | 22 | 30 | 905 | 581 | 1486 | 380 | 340 | 335 |
| XRF125-2-2A | 22 | 30 | 905 | 581 | 1486 | 380 | 340 | 335 |
| XRF125-2-2 | 22 | 30 | 905 | 581 | 1486 | 380 | 340 | 385 |
| XRF125-2-1A | 30 | 40 | 905 | 619 | 1524 | 380 | 340 | 387 |
| XRF125-2-1 | 30 | 40 | 905 | 619 | 1524 | 380 | 340 | 387 |
| XRF 125-2 | 37 | 50 | 905 | 735 | 1640 | 421 | 360 | 410 |
| XRF125-3-3 | 37 | 50 | 905 | 735 | 1640 | 421 | 360 | 414 |
| XRF 125-3-2 | 45 | 60 | 1057 | 735 | 1792 | 421 | 360 | 500 |
| XRF125-3-1 | 45 | 60 | 1057 | 735 | 1792 | 421 | 360 | 502 |
| XRF125-3 | 55 | 75 | 1057 | 760 | 1817 | 463 | 385 | 585 |
| XRF125-4-3 | 55 | 75 | 1179 | 760 | 1939 | 463 | 385 | 586 |
| XRF 125-4-2A | 55 | 75 | 1179 | 760 | 1939 | 463 | 385 | 586 |
| XRF125-4 | 75 | 100 | 1179 | 910 | 2089 | 505 | 405 | 705 |
| XRF 125-5-2 | 75 | 100 | 1301 | 910 | 2211 | 505 | 405 | 719 |
| XRF125-5 | 90 | 120 | 1301 | 910 | 2211 | 505 | 405 | 803 |
PerformanceCurve
Outline Drawing
Dimension/Weight
| MODEL | KWPOWER | WEIGHT | ||||||
| HP | B1 | DIMENSION(UNIT:mm) | D1 | D2 | ||||
| XRF 155-1-1A | 15 | 20 | 783 | 528 | 1311 | 330 | 315 | 201 |
| XRF155-1-1 | 18.5 | 25 | 783 | 558 | 1341 | 330 | 315 | 218 |
| XRF155-1A | 22 | 30 | 783 | 581 | 1364 | 380 | 340 | 267 |
| XRF155-1 | 30 | 40 | 783 | 619 | 1402 | 380 | 340 | 272 |
| XRF 155-2-2B | 30 | 40 | 905 | 619 | 1524 | 380 | 340 | 277 |
| XRF 155-2-2A | 37 | 50 | 905 | 735 | 1640 | 421 | 360 | 410 |
| XRF 155-2-2 | 37 | 50 | 905 | 735 | 1640 | 421 | 360 | 410 |
| XRF155-2-1A | 45 | 60 | 935 | 735 | 1670 | 421 | 360 | 490 |
| XRF155-2-1 | 45 | 60 | 935 | 735 | 1670 | 421 | 360 | 490 |
| XRF155-2A | 45 | 60 | 935 | 735 | 1670 | 421 | 360 | 492 |
| XRF155-2 | 55 | 75 | 935 | 760 | 1695 | 463 | 385 | 585 |
| XRF155-3-3 | 55 | 75 | 1057 | 760 | 1817 | 463 | 385 | 590 |
| XRF155-3-2 | 75 | 100 | 1057 | 910 | 1967 | 505 | 405 | 702 |
| XRF155-3-1 | 75 | 100 | 1057 | 910 | 1967 | 505 | 405 | 702 |
| XRF155-3 | 75 | 100 | 1057 | 910 | 1967 | 505 | 405 | 702 |
| XRF155-4-3 | 75 | 100 | 1179 | 910 | 2089 | 505 | 405 | 707 |
| XRF155-4-1 | 90 | 120 | 1179 | 910 | 2089 | 505 | 405 | 797 |
| XRF155-4 | 90 | 120 | 1179 | 910 | 2089 | 505 | 405 | 799 |
| XRF 155-5-2 | 110 | 150 | 1311 | 950 | 2261 | 550 | 505 | 992 |
PerformanceCurve
Dimension/Weight
| MODEL | POWER | WEIGHT | ||||||
| kW | HP | B1 | B2 | DIMENSION(UNIT:m)D1 | D2 | |||
| XRF185-1-1C | 18.5 | 25 | 868 | 558 | 1426 | 330 | 315 | 354 |
| XRF185-1-1B | 22 | 30 | 868 | 581 | 1449 | 380 | 340 | 403 |
| XRF 185-1-1A | 30 | 40 | 868 | 619 | 1487 | 380 | 340 | 415 |
| XRF 185-1-1 | 30 | 40 | 868 | 619 | 1487 | 380 | 340 | 415 |
| XRF 185-1 | 37 | 50 | 868 | 735 | 1603 | 421 | 360 | 548 |
| XRF185-2-2D | 45 | 60 | 1026 | 735 | 1761 | 421 | 360 | 581 |
| XRF185-2-2C | 45 | 60 | 1026 | 735 | 1761 | 421 | 360 | 581 |
| XRF185-2-2B | 55 | 75 | 1026 | 760 | 1786 | 463 | 385 | 649 |
| XRF 185-2-2A | 55 | 75 | 1026 | 760 | 1786 | 463 | 385 | 649 |
| XRF 185-2-2 | 55 | 75 | 1026 | 760 | 1786 | 463 | 385 | 649 |
| XRF 185-2-1 | 75 | 100 | 1026 | 910 | 1936 | 505 | 405 | 807 |
| XRF185-2 | 75 | 100 | 1026 | 910 | 1936 | 505 | 405 | 807 |
| XRF185-3-3A | 75 | 100 | 1154 | 910 | 2064 | 505 | 405 | 823 |
| XRF185-3-3 | 90 | 120 | 1154 | 910 | 2064 | 505 | 405 | 853 |
| XRF 185-3-2 | 90 | 120 | 1154 | 910 | 2064 | 505 | 405 | 853 |
| XRF185-3 | 110 | 150 | 1184 | 950 | 2134 | 550 | 505 | 1120 |
| XRF185-4-4A | 110 | 150 | 1312 | 950 | 2262 | 550 | 505 | 1138 |
| XRF185-4-4 | 132 | 175 | 1312 | 950 | 2262 | 550 | 505 | 1208 |
| XRF185-4-2 | 132 | 175 | 1312 | 950 | 2262 | 550 | 505 | 1208 |
| XRF 185-4-1 | 132 | 175 | 1312 | 950 | 2262 | 550 | 505 | 1208 |
| XRF185-4 | 132 | 175 | 1312 | 950 | 2262 | 550 | 505 | 1208 |
PerformanceCurve
Dimension/Weight
| MODEL | POWER | DIMENSION(UNIT:mm) | WEIGHT (kg) | |||||
| kW | HP | B1 | B2 | B1+B2 | D1 | D2 | ||
| XRF215-1-1C | 18.5 | 25 | 868 | 558 | 1426 | 330 | 315 | 354 |
| XRF215-1-1B | 30 | 40 | 868 | 619 | 1487 | 380 | 340 | 415 |
| XRF 215-1-1A | 30 | 40 | 868 | 619 | 1487 | 380 | 340 | 415 |
| XRF 215-1-1 | 37 | 50 | 868 | 735 | 1603 | 421 | 360 | 548 |
| XRF215-1A | 45 | 60 | 898 | 735 | 1633 | 421 | 360 | 567 |
| XRF215-1 | 55 | 75 | 898 | 760 | 1658 | 463 | 385 | 625 |
| XRF 215-2-2A | 55 | 75 | 1026 | 760 | 1786 | 463 | 385 | 649 |
| XRF215-2-2 | 75 | 100 | 1026 | 910 | 1936 | 505 | 405 | 807 |
| XRF 215-2-1A | 75 | 100 | 1026 | 910 | 1936 | 505 | 405 | 807 |
| XRF215-2-1 | 90 | 120 | 1026 | 910 | 1936 | 505 | 405 | 837 |
| XRF215-2 | 110 | 150 | 1056 | 950 | 2006 | 550 | 505 | 1067 |
| XRF215-3-2A | 110 | 150 | 1184 | 950 | 2134 | 550 | 505 | 1120 |
| XRF 215-3-2 | 132 | 175 | 1184 | 950 | 2134 | 550 | 505 | 1174 |
| XRF215-3-1A | 132 | 175 | 1184 | 950 | 2134 | 550 | 505 | 1175 |
| XRF 215-3-1 | 160 | 215 | 1184 | 1150 | 2334 | 618 | 550 | 1538 |
| XRF 215-3 | 160 | 215 | 1184 | 1150 | 2334 | 618 | 550 | 1538 |
| XRF 215-4-2A | 160 | 215 | 1312 | 1150 | 2462 | 618 | 550 | 1556 |
PerformanceCurve
Outline Drawing
| MODEL | POWER | WEIGHT | ||||||
| kW | HP | B1 | DIMENSION(UNIT:mm) | D1 | D2 | |||
| XRF255-1-1C | 30 | 40 | 868 | 619 | 1487 | 380 | 340 | 415 |
| XRF255-1-1B | 30 | 40 | 868 | 619 | 1487 | 380 | 340 | 415 |
| XRF255-1-1A | 37 | 50 | 868 | 735 | 1603 | 421 | 360 | 548 |
| XRF255-1-1 | 45 | 60 | 898 | 735 | 1633 | 421 | 360 | 567 |
| XRF255-1B | 55 | 75 | 898 | 760 | 1658 | 463 | 385 | 625 |
| XRF255-1A | 55 | 75 | 898 | 760 | 1658 | 463 | 385 | 625 |
| XRF255-1 | 75 | 100 | 898 | 910 | 1808 | 505 | 405 | 789 |
| XRF255-2-2C | 75 | 100 | 1026 | 910 | 1936 | 505 | 405 | 807 |
| XRF255-2-2B | 75 | 100 | 1026 | 910 | 1936 | 505 | 405 | 807 |
| XRF255-2-2A | 90 | 120 | 1026 | 910 | 1936 | 505 | 405 | 837 |
| XRF 255-2-2 | 90 | 120 | 1026 | 910 | 1936 | 505 | 405 | 837 |
| XRF255-2-1A | 110 | 150 | 1056 | 950 | 2006 | 550 | 505 | 1067 |
| XRF255-2-1 | 110 | 150 | 1056 | 950 | 2006 | 550 | 505 | 1067 |
| XRF255-2A | 110 | 150 | 1056 | 950 | 2006 | 550 | 505 | 1067 |
| XRF255-2 | 132 | 175 | 1056 | 950 | 2006 | 550 | 505 | 1156 |
| XRF255-3-3 | 132 | 175 | 1184 | 950 | 2134 | 550 | 505 | 1174 |
| XRF255-3-2A | 132 | 175 | 1184 | 950 | 2134 | 550 | 505 | 1174 |
| XRF255-3-2 | 160 | 215 | 1184 | 1150 | 2334 | 618 | 550 | 1538 |
| XRF255-3-1 | 160 | 215 | 1184 | 1150 | 2334 | 618 | 550 | 1538 |
| XRF255-3 | 200 | 268 | 1184 | 1189 | 2373 | 660 | 507 | 1700 |
| XRF 255-4-2 | 200 | 268 | 1312 | 1189 | 2501 | 660 | 507 | 1718 |
| XRF255-4-1 | 225 | 300 | 1352 | 1292 | 2644 | 800 | 644 | 2063 |
| DPC25-6M | DPC32-6M | DPC40-8M | DPC50-12M | DPC50-15M | DPC50-18M | |
| InputPower | 1 Phase220V/60Hz | |||||
| Max. Head (m) | 6 | 6 | 8.5 | 12 | 15 | 18 |
| Max.FlowRate | 3.6 | 3.6 | 9 | 11 | 12 | 20 |
| Suction Discharge gauge | 25A | 32A | 40A | 50A | 50A | 50A |
| 3StepsSpeed-Control | × | × | X | |||
Feature
Feature
It can be used at high temperature (-10℃\~+90℃)
It can be used at high pressure (Max. 6bar)
·Hot-water Circulating Pump ·Industry
EHIGHY1EASY国
Easyinstallationbycompact design
中
Noiseless
3 Steps Speed Control
| MODEL | INPUTPOWER | CMASUPPWION (W) | MAX.HEAD | MAX.FLOW RATE | SUCTUNEmmCHARGE |
| DPC25-6M | 1 Phase 220V/60Hz | 80 | 6 | 3.6 | 25(1") |
| MODEL | INPUTPOWER | MAX.POWER CONSUMPTION (W) | MAX.HEAD (m) | MAX.FLOWRATE (m³/hr) | SUCTION·DISCHARGE GAUGE(mm,inch) |
| DPC40-8M | 1Phase220V/60Hz | 240 | 8.5 | 9 | 40(1) |
Feature
It can be used at high temperature (-10℃\~+90℃)
It can be used at high pressure (Max.10bar)
· Hot-water Circulating Pump · Industry
Y4 EASY
Easy installation bycompact design
中
Noiseless
| MODEL | INPUTPOWER | MAX.SHAFTPOWER (W) | MAX.HEAD (m) | MAX.FLOWRATE (m³/hr) | SUCTION·DISCHARGE GAUGE(mm,inch) |
| DPC50-12M | 1 Phase 220V/60Hz | 500 | 12 | 11 | 50(2") |
| MODEL | INPUTPOWER | MAX.SHAFTPOWER (W) | MAX.HEAD (m) | MAX.FLOWRATE (m³/hr) | SUCTION·DISCHARGE GAUGE(mm,inch) |
| DPC50-15M | 1 Phase 220V/60Hz | 550 | 15 | 12 | 50(2") |
SEWAGELIFTING PUMP SYSTEM NDPS SERIES
No-Blockage & Hygienic DOOCH OSC SYSTEM 'Sewage Lifting Pump System ?
Minimizemaintenance cost
- Designed as bottom-discharge type to reduce floor areaandavoidsedimentsin the tank -HDPE(highdensitypolyethylene) material:High chemical resistant&durability/Save the cost of regular tank deaning
Hygienicmaintenance
-Able to clean waste inside beforea pump maintenance - Able to clean inside in various ways / dismounting pump is easy and hygienic
Best performance -No Blockage
-Dooch's cutting edge pumps(grinder,voltex) installed : Noblockageatall - High performance motor that is usable on land / Grinder type pump that can shred solids and avoid fixation.
Easyinstallation
-Pump is mounted on the specialized,hard and hydraulics structured stand. -Easy to installas the dismountable vertical sewage tank is in slimsize -Easy to dismount as hard and big pipe is assembled -At-site labor isunnecessaryas itcomesout ina finished-product
Highdurabilitymaterial/ Highperformancemotor
-High intensity stainless steel(Hi-Cr steel) cutter installed : for grinder pump -Low operation cost by high performance motor and hydraulics structure
※Smartoverloadoperationfunction (Functionthatavoidsinletblockage)
Protectionfunctionoperateswhenpump'scurrentgets 1 3 0 { ~ } 1 5 0 % duetoimpeller'srestrain:TryCCWrotation-CWrotation-CCWrotationCWrotation→CCWrotation→CWrotation'butif itstilldoesn'trunnormally, pumpstopsandrunsoffalarm.
Features
-System based on OSC
-High-durability HDPE(High-density polyethene) sewage tank (Selectamong 200L/350L/500L)
-Afully discharged tank that facilitates discharge of suspended andsedimentarymaterials
-Sewage-specificfloat switch applied (Increased buoyancy of itsown,evenunder conditionswith alargeamountoffloatingmatters)
What is OsC method?
Of-site construction means putting together modules madeina factoryat the installation site,away from the existing on-site productionsystem,to make sure accidents like welding and cuting are less likelyto happen. As field work is reduced, 40 % of conventional waste generation is reduced by 5 %
OSC Introduction Background
Background Problem Introduction of OsC method
·The aging of the skilled ·Adecline inoverall quality · Quality is stable with professional
workforce manpower production ·Increase insafetyaccidents
· Increase in low-skilled workers ·Preventing safetyaccidentsby reducing dangerouswork ·An increase in construction period ·Pre-production reduces ·Anincreaseof on-sitemanagement construction time costs ·Reduce overall construction costs ·Waste reduction
| Category | dooch | A company | B company |
| Pumpinstallation position | Outside | Outside | Outside |
| Pumpconnection method | All-in-one type | IndividualInstallation | IndividualInstallation |
| Pump type | Grinder,Volt | Voltex | NImpeller in voltextype |
| Tank capacity | 200~500L | 400L/1,200L | 800L |
| Tankmaterial | *HDPE (High-densitypolyethylene) | PE (Polyethylene) | FRP (reinforced plastic) |
| Product size | 60% (500L) | 100% (400L) | 95% (800L) |
| Deliverymethod | :All-in-onesetdelivery | Field assembly | Fieldassembly |
What is Sewage lifting pump system?
Introduction of model name
Sewage lifting pump system isa system made by collecting and reducing the weightof the septic tank inan environment where natural drainage is not possible,suchasmulti-family buildings or underground buildings,and provides an optimal solution for the site.
Areasofapplication
Multi-family buildings,houses,apartments,residential and commercial complexes,sewage treatment plants,manholes, breeding grounds,etc.that do not naturally drain
AppliedModel
| Category | 200L | 350L | 500L | |||||||||
| Power (kW) | 1.5 | 2.2 | 1.5 | 2.2 | 3 | 4 | 1.5 | 2.2 | 3 | 4 | 5.5 | 7.5 |
Component
\*Specification
| Casematerial | ABS (OPTION: STAINLESS STEEL) | ||
| Display | 4.3”TFTLCD/KEYPAD | ||
| Number of pump | 2~3pumps | ||
| Ratedcapacity | 1~5HP | 7.5~10HP | 15~30HP |
| Maximumswiantityof | Max.4 | ||
| InputPower | 3Ox220V/380V/440V,50~60Hz | ||
\*Key functions
-Overloadprotection -Alternatingoperationbasedon accumulatedoperationtime
- Dry running protection -Paneltemperature, humiditydetection
※Overload protection(Inlet-blockageprotection)
If 1 3 0 - 1 5 0 % overloadof pumpcurrentvalueduetoimpeller constraintduringpumpoperation,protectionstarts:Try'CCWrotation CWrotation→CCWrotation→CWrotation→CCWrotation→CWrotation butif itstilldoesn'trunnormally,pumpstopsandrunsoffalarm.
NDPS200Series
doooh O
MOTOR-INDEPENDENT,MICROPROCESSORBASED ENERGYSAVINGPUMPCONTROLSYSTEM.
| XQ-Drive | NSQ-Drive | SQ2-Drive | |
| Single phase model | Availablepower:1.1~2.2kW Input power:1Phase,200~230V Output power:3Phase,200~230V | ||
| Threephasemodel | Availablepower:0.75~22kW Inputpower:3Phase,380~440V Outputpower:3Phase,380~440V | Availablepower:0.75~22kW Inputpower:3Phase,380~440V Outputpower:3Phase,380~440V | |
| Main frequency | 50/60Hz | 50/60Hz | 50/60Hz |
| IP Class | IP55 | IP55 | IP55 |
| Ambienttemperature | -10~+40C° | -10~+40C° | -10~+40C° |
| Connections | RS485port | RS485 port (OPTION) | |
| Pressure transmitter | 4~20mA | 4~20mA | 4~20mA |
| Display | Graphic LCD type (3.5") | FND type (5 digits) | FND type (5 digits) |
| Built-in-devices | Built-in EMC filter (IEC61800-3) Buil-in DC reactor | External (OPTION) | External (OPTION) |
XQ-DRIVE
XQ-Drives are pump specific variable frequency drive that manage pump performance to match a wide range ofsystemconditionsandrequirement.
Adjusting the pump speed is the most efficient means of controlling pump flow and reducing the energy consumption.
Asthe Drivesare self-cooling and motor-independent structure,it can be mounted directly on the motor or on the wall.
Application
·Pressure boosting system
·Water treatment and processing
·HVAC applications
·Wash system
·Process water
Technical Specification
·Available power:0.75\~22kW
·Input power:3Phase,380\~440V
·Output power:3Phase,380\~440V
·Main frequency:50/60Hz
·Maximum frequency: 6 0 H z
·IPClass:IP55
·Maximumdistance of pressure transmitter from drive10 meters
·Ambient temperature - 1 0 ^ { \circ } C to 4 0 ^ { \circ } \mathsf { C }
·Humidity 5 0 % at 4 0 ^ { \circ } \mathsf { C } and 9 0 % at 2 0 ^ { \circ } \mathsf { C }
Protections
·Dry running 中
·Lowwater level detection
·Minimum flow stop
·Over/under voltage
·Inverterover temperature
·Pressure setting
·Sensor failure
·Pump freezing
·Pump overload
Features
·New hardware design (LCD display type) ·Energy savings up to 7 0 % (204号 ·Multipump control capability up to 6 pumps ·Control mode-pressure/differential pressure ·Hydraulic control functions included ·Electrical and hydraulic pump protections ·Automatic recovery after power failure ·Easy retrofitting on existing pump system ·Mounteddirectlyonstandard I.E.C.motors · Flexible installation(motor,wal) ·Built-in EMC filterand DC reactor -Reduced noise and harmonic distortion
Application
NSQ-Drives are pump specific variable frequency drive that manages pump performance to match a wide range ofsystemconditionsandrequirement.
Adjusting the pump speed is the most efficient means of controlling pump flow and reducing the energy consumption.
As the Drivesare self-cooling and motor-independent structure,it can be mounted directly on the motor or on the wall.
·Pressure boosting system
·Water treatment and processing
· HVAC applications
·Wash system
·Processwater
Technical Specification
·Available power:0.75\~22kW
·Input power:3Phase,380\~440V
·Output power:3Phase,380\~440V
·Main frequency:50/60Hz
·Maximum frequency \because 6 0 H z
· IPClass:IP55
·Maximumdistance of pressure transmitter fromdrive10meters
·Ambient temperature - 1 0 ^ { \circ } C to 4 0 ^ { \circ } \mathsf { C }
·Humidity 50 % at 4 0 ^ { \circ } \mathsf { C } and 9 0 % at 2 0 ^ { \circ } \mathsf { C }
Protections
· Dry running ?
·Lowwater level detection
·Minimum flow stop
· Over/under voltage
· Inverter over temperature
·Pressure setting
·Sensor failure
·Pump freezing
·Pump overload
Features
·Energy savings up to 7 0 %
·Multipump control capability up to 6 pumps
·Control mode-pressure/differential pressure
·Hydraulic control functions included
·Electrical and hydraulic pump protections
·Automatic recovery after power failure
·Easy retrofiting on existing pump system
·Mounteddirectlyonstandard I.E.C.motors
· Flexible installation(motor,wall)
·FND display for easy status monitoring and programming
SQ2-DRIVE
Application
SQ2-Drive is a single phase specific pump controller which adjusts the pump speed to maintain constant pressure,evenwhen demand forwater changes. Adjusting the pump speed is the most efficient means of controlling pump flow and saving the energy. AsSQ2-Drive ismotor-independentfrequency inverter, it can be mounted directly on the motor or the wal.
·Pressure boosting system
·Water treatment and processing
·Wash down
·Portable water supply
·Commercial watersupply
·Boiler feed
TechnicalSpecification
Protections
·Availablepower \because 1.1\~2.2kW
· Input power:1Phase,200\~230V
·Output power:3Phase,200\~230V
·Main frequency:50/60Hz
·Maximum frequency: 6 0 H z
· IPClass:IP55
·Maximumdistance of pressure transmitter fromdrive10meters
·Ambient temperature - 1 0 ^ { \circ } C to 4 0 ^ { \circ } \mathsf { C }
•Humidity 5 0 % at 4 0 ^ { \circ } \mathsf { C } and 90 % at 2 0 ^ { \circ } \mathsf { C } (2
· Dry running
·Lowwater level detection
·Minimum flow stop
·Over/under voltage
·Inverter over temperature
·Pressure setting
·Sensor failure
·Pump freezing
·Pump overload
Features
·Stand-alone inverter fora single pump
·Hydraulic control functions included
·Electrical and hydraulic pump protections
·Easy retrofitting on existing pump system
·Flexible installation (motor,wall)
·Small compact design and space saving
·FND display for easy status monitoring and programming
Features
● Full-color display
· User-friendly touch screen interface
·Easy to set pressure
·lcons include;Historyof run/alarmandothervarious information
·Languages include;Korean/English/Chinese
·Integral monitoring system; gather information of each drive via CAN communication
·Comfortable UX Interface/GUl; high-quality user recognition rate&operability
·Easy firmware upgrade with usb port
ConfigurationofLCDMonitor
Functions
·Lcd touchscreen-Large LCDscreen;indicatevarious information graphically
·Language selection-Korean(Standard)/English/Chinese
● Digital I/O function-Run system by external digital input/control function; stop,alarm etc. ●Analog I/O function-Convert 4\~20mA of external signal internally or internal signal externally ·Schedule run-Operatable in different pressure values by time/date/month
·Record&save run history-Recordand savevarious run histories inSDcardonareal-timebasis · Indicate& save alarm content-Indicateand save various alarm/breakdown content
·Remote monitoring system- Monitor running status & alarm remotely with integrated contact ·CAN communication-Connected with booster pump system
·RS-485 communication-Connected with external devices
| Category | Screen layout |
| Pump status | |
| Trend | |
| ③ | Currentdate/time |
| Current pressure value | |
| Run/Stop | |
| ® | Settings |
| 0 | Currentalfra ionaraiol |
| 8 | Run history |
| 9 | Indicator |
| 10 | Current pressure |