| Model | NSQ-Drive | SQ2-Drive (1PH) |
| Features | ||
| Specification | Motor Power: 0.4~22kW Input : 1PH200~230V (0.4~2.2kW) 3PH 380-440V(0.75~22KW) Output:3PH220~440V Frequency:50/60Hz | Motor Power: 0.75~2.2kW Input : 1PH200~230V (0.75~2.2kW) Output:3PH200~230V Frequency: 50/60Hz 7"touch monitor is un-adaptable |
| NSQP-2DHF(T) Series IndividualInverterHorizontal BoosterSystem (PremiumModel) | SQ2-2DHF(T)Series IndividualInverterHorizontalBoosterSystem | |
| Appearance | ||
| Features | ·7" LCD touch monitor ·All pumpsare fitted with an integrated V.F.D.which are directly mounted on themotor · High reliability ·Communication between pumps | All pumpsarefittedwithanintegrated V.F.D.whichare directlymounted on themotor ·High reliability ·Constant discharge pressure ·Lowest energy consumption |
| Inverters | (NSQ-Drive) | (SQ2-Drive) |
| Manifolds | StandardManifold | StandardManifold |
| Panel | NEQ 7"LCD Touch 3.5" Color display Screen Monitor (The latest GUl isapplied) |
| NSQ-DHF(T) Series IndividualInverterHorizontalPump | SQ2-DHF(T)Series Individual InverterHorizontalPump | |
| Appearance | ||
| Features | ·Equipped with a NSQ-Drive · High reliability ·Maintains constant pressure ·Soft start functionality ·Compactdesign/Easyinstallation | Equipped witha SQ2-Drive HighReliabilityreliability ·Maintains constant pressure ·Softstartfunctionality Compactdesign/Easy installation |
| Inverters | (NSQ-Drive) | (SQ2-Drive) |
| Manifolds | CheckValve | Check Valve |
| NSQ-DHMSeries IndividualInverter HorizontalPump | SQ2-DHMSeries IndividualInverter HorizontalPump | |
| Appearance | ||
| Features | ·Equipped witha NSQ-Drive · High reliability ·Maintains constant pressure ·Soft start functionality ·Compact design/Easy installation | Equippedwitha SQ2-Drive ·High reliability Maintainsconstant pressure ·Softstart functionality ·Compactdesign/Easy installation |
| Inverters | (NSQ-Drive) | (SQ2-Drive) |
| Manifolds | CheckValve | Check Valve |
SQ2-Drive
SQ2-Drive is a single phrase variable frequency drive that manages pump performance to match awide range of system conditionsand requirements.Adjusting the pump speed is the most efficient means of controlling the pump flow and reducing theenergy consumption.
SQ2-Drive isamotor-independent structure,itcanbemounted directly on themotor or on the wall.
TechnicalSpecification
| AvailablePower | 0.37~22kW |
| Input Power | 1Φ×200~230V |
| Output Power | 3Φ×200~230V |
| Frequency | 50/60Hz |
| Max.Frequency | 60Hz |
| IP Class | IP 55 |
| Max.Distance Of PressureTransmitter | Max.10m |
| Ambient Temp. | -10℃~+40°℃ |
5
SQ-Drive Features
1Stand alone inverter for a single pump Hydraulic control functions included Electrical and hydraulic pump protections Easy retrofitting on existing pump systems Flexible installations(motor,all) Small compact design and space saving FND display for easy status monitoring and programing
Protections
·Dry Running
·LowWaterLevel Detection
·Over/Under Voltage Inverter
·Min.Flow Stop
·Temp.Pressure Seting
·Sensor Failure
·Pump Freezing
·Pump Overload
NSQ-DRlVESare pump specific variable frequency drive that managespumpperformancetomatchawiderangeofsystem conditions and requirements.Adjusting the pump speed is the most efficient means of controlling pump flow and reducing the energy consumption.
Asthedrivesareself-coolingand motor-independent structure, it can be mounted directly on the motor or on the wall.
5
Technical Specification
Protections
| AvailablePower | 0.55~22kW |
| InputPower | 3Φ×380~440V (0.55~22kW) |
| Output Power | 3Φ×380~440V (0.55~22kW) |
| Frequency | 50/60Hz |
| Max.Frequency | 60Hz |
| IP Class | IP 55 |
| Max.Distance Of Pressure Transmitter | Max.10m |
| Ambient Temp. | -10℃~+40°℃ |
·Dry Running
·Low Water Level Detection
·Over/Under Voltage Inverter
·Min.Flow Stop
·Temp.Pressure Seting
·Sensor Failure
·Pump Freezing
·Pump Overload
NSQ-DriveFeatures
1EnergySavings upto 7 0 % (204号
±b { θ } Multi-pump control capacity of up to 6 pumps
±b { \Theta } Hydraulic control functions included
\bullet Electrical and hydraulic pump protections
\bullet Automaticrecoveryafter power failure
\odot Easy retrofitting on existing pump system
±b { { O } } Flexible instalation either directly on a standard I.E.C.motors or on walls
ColorMonitorTM3.5
TM3.5 monitor receives data from pumps with inverters, and provides the integrated information for user'seasy understanding. Also,itiseasy toset the system pressure,and user can understand the various pump information such as pump operation logoralarm log,withuser-friendlyUXandGUl.
5
Specification
| InputPower | 1Φx200~440V/50~60Hz |
| Communication Port | RS485 communication MOD BUS-RTU |
| Display | 3.5"TFT TRUE COLOR LCD(320×240) |
| Multi-function Input/Output | SYSTEM RUN output relay contact SYSTEMFAULToutput relaycontact |
| StorageMedium | SDcard available (Logging data storage) |
| Update Port | USB×1EA |
Properties
Full color display
Easytosetthepressure
Iconsincludes;HistoryofRun/Alarmandvariousinformation
Languagesincludes;Korean/Chinese/English
RS-485: Integrated communication with each drive information
USBPORT:Firmware upgrade port
Availableupto3pumps
Loggingdatarecords (Seting pressure,Current setting,Operation data of each pump)
Features
·Full Color Display
·Touch Screen Interface
·User-Friendly/Easyto function
·Icons includes;History ofRun/Alarmand other various information
·Languages include;Korean/Chinese/English
·RS485:Integrated communication
·USB PORT: Firmware upgrade port
Specification
·7"TFTLCD
·Touch Screen Monitor
·RS-485 PORT:2 ports
·CANCOM.PORT:1
·Run/Alarmcontact
·Power:220\~440V
·Temp.& Humidity:-10\~40℃/90% Under
·USB PORT
| Models | Available | Unavailable |
| NSQ-Series | ||
| NSQP-Series |
ThePafter themodel namemeansapremiummodelwith an LCDtouch screen monitor.
GUI(GraphicUserInterface) Introduction
1. Current Date and Time
2.Setting Pressure Value
3. Current Pressure Value
4. Current Output Ratio
5. Icon/Current condition of each pumps (Up to 6 pumps)
| Ratio Current operating ratio | Current Current Value | ||
| W | Power Current power consumption | Frequency Current operating frequency | |
| Accumulated Power Current Power accumulation | Output Power Current Output Power |
6. Status
7. Run History
8.Set-Up
Specification
·Max.Flow(Q):70m³/h
·Max.Head(H):103m
·No.of pumps:Up to 2 pumps (Please contact the office for3 pumps)
·InputPower:3PH380V\~440V/60Hz(0.75\~10HP)
NSQP-2DHF(T) Series
NSQP-2DHF(T) series is built on the basis of DHF pumps.The main difference between the DHF and the NSQP-DHF(T) pump is the variable frequency drive.Enhanced with the NSQ-Drive, NSQP-2DHF(T) series with the appropriate sensor is turned into an intelligent, variable speed pumping system.The NSQ-Drives adjust the motor speed which in turn provides constant pressure or differential pressure to the flow rate. NSQP-2DHF(T) isalso equipped with the 7" touch screenmonitor that isembedded into the panelwhich features the lastest GUl.
※Inlet/Outletcasingmaterial "T" indicates:GCD450 Without "T" indicates:Stainlesssteel
Functions
·Control Mode-Pressure/differential pressure
·Set the setting pressure
·Dry-running and freeze protection
·Automatic flowless sensor
·Automatic recoveryafterpower failure Inverter
·Pump protection
·FND-Status monitoring
·Equipped with a RS485-Optional
Features
7"colorLCDtouchmonitor
·Each pump is individually controlledbya NSQdrive
·High reliability (Multi-mastercontrol)
·Constant discharge pressure
·Reducedtankandpanelsizes
·Less wear of the system during operation
·Compact assembly and installation
Applications
·Pressure boosting systems ·Domestic water supply systems ·Cooling systems ·Air-conditioning systems ·Small industrial water supply systems ·Horticultural irrigation systems
·Alternative Operation
-Alternativeoperationreferstothe total sumof the poweraccumulated -Thisin-return ensures that the operating of each pumpwillbe thesameand extends the life-line of each pumpas the wear isevenly distributed amongst the pumps.
Specification
·Max.Flow(Q): 7 0 m ^ { 3 } / h
·Max.Head(H):103m/h
·No.of pumps:Up to 2 pumps (Please contact the office for 3 pumps)
·InputPower:3PH380V\~440V/60Hz(0.75\~10HP)
NSQ-2DHF(T) Series
NSQ-2DHF(T) series is built on the basis of DHF pumps.The main difference between the DHF and the NSQ-DHF(T) pump is thevariable frequencydrive.Enhancedwith the NSQ-Drive, NSQ-2DHF(T) series with theappropriatesensor is turned into anintelligent,variablespeed pumpingsystem.The NSQ-Drives adjust themotorspeedwhich in turn providesconstant pressure ordifferential pressure to the flowrate.
※Inlet/Outletcasingmaterial "T" indicates:GCD450 Without "T" indicates:Stainlesssteel
5
Functions
·Control Mode-Pressure/differential pressure
·Set the setting pressure
·Dry-running and freeze protection
Automaticflowlesssensor
·Automaticrecoveryafterpower failure Inverter
·Pump protection
·FND- Status monitoring
·Equipped witha RS485-Optional
●3.5"Color display(The latest GUl isapplied)
·Each pump isindividually controlled byaNSQdrive
Highreliability (Multi-mastercontrol)
·Constant discharge pressure
·Reduced tank and panel sizes
·Less wear of the system during operation
·Compact assemblyand installation
Applications
Pressureboostingsystems ·Domestic water supply systems ·Cooling systems ·Air-conditioning systems ·Small industrial watersupply systems ●Horticultural irrigation systems
·AlternativeOperation
-Alternativeoperationrefersto the total sumof the poweraccumulated -This in-return ensures that the operating of each pump will be the same and extends the life-line of each pump as the wear is evenly distributed amongst the pumps.
Specification
SQ2-2DHF(T) Series
·Max.Flow(Q):70m³/h
·Max.Head(H):103m³/h
·No.of pumps:Up to 2 pumps
·InputPower:1PH200V\~230V/60Hz(0.5\~3HP)
SQ2-2DHF(T)series is built on the basis of DHF pumps.The main difference between the DHF and the SQ2-2DHF(T) pump is the variable frequency drive.Enhanced with the SQ2-Drive,SQ2-2DHF(T) pumptogetherwith the appropriate sensor is turned into an intelligent,variable speed pumping system.The SQ2-Drives adjustthemotorspeedwhichinturn providesconstantpressure ordifferential pressure to theflowrate.
※Inlet/Outletcasingmaterial "T" indicates:GCD450 Without"T"indicates:Stainlesssteel c
Functions
·ControlMode-Pressure/differential pressure
·Set the setting pressure
·Dry-runningand freezeprotection
·Automatic flowless sensor
·Automaticrecoveryafter power failure Inverter
·Pump protection
·FND- Status monitoring
·Each pump is individually controlled bya SQ2 drive ·Highreliability(Multi-mastercontrol) ·Constantdischarge pressure ·Less wear of the system during operation ·Compact assembly and installation
Applications
·Pressure boosting systems ·Domestic water supply systems ·Cooling systems ·Air-conditioning systems ·Smallindustrial water supply systems ·Horticultural irrigationsystems
Specification
NSQ-DHF(T) Series
·Max.Flow(Q):35m³/h NSQ-DHF(T) series is built on the basis of DHF pumps.The
Max.Head(H):103m³/h main difference between the DHFand the NSQ-DHF(T) seriesi
·Motor Power:0.55\~7.5kW(0.75\~10HP) the variable frequency drive.Enhanced with the NSQ-Drive, NSQ-DHF(T) series with the appropriate sensor is tumed
·InputPower:3PH380V\~440V/60Hz(0.75\~10HP) intoan intelligent, variable speed pumping system.The NSQ-Drives adjust the motor speed which in turn provides constant pressure ordifferential pressure to the flowrate. Inlet/Outlet casing material MAX 103m "T" indicates:GCD450 Without "T" indicates:Stainlesssteel 75m 50m 35m/h 25m X 0m
Functions Features
·Control Mode-Pressure/differential pressure ·Each pump is individually controlled bya NSQ drive
·Set the setting pressure Highreliability (Multi-mastercontrol)
·Dry-running and freeze protection Constantdischarge pressure
·Automatic flowless sensor ·Less wear of the system during operation
·Automatic recoveryafter power failure Inverter ·Compact assemblyand installation
·Pump protection
·FND-Status monitoring .
Applications
·Pressure boosting systems ·Domestic water supply systems ·Cooling systems ·Air-conditioning systems ·Small industrial water supply systems ·Horticultural irrigation systems
Specification SQ2-DHF(T) Series
·Max.Flow(Q):35m³/h SQ2-DHF(T) series is built on the basis of DHF pumps.
·Max.Head(H):103m The main difference between the DHF and the SQ2-DF
MotorPower:0.37\~2.2kW(0.5\~3HP) series is the variable frequency drive. Enhanced with theSQ2-Drives,SQ2-DHF(T) series with the
·InputPower:1PH200V\~230V/60Hz(0.5\~3HP) appropriatesensor is turmed intoan intelligent,variable speed pumping system.The SQ2-Drives adjust the mot speed which in turn provides constant pressure or differential pressure to the flowrate. MAX 103m ※Inlet/Outlet casing material "T" indicates:GCD450 75m Without "T" indicates:Stainlesssteel 50m 35m/h 25m X 0m
Functions Features
·Control Mode-Pressure/differential pressure Eachpumpisindividuallycontrolled bya SQ2Drive
·Set the setting pressure ·Highreliability (Multi-mastercontrol)
·Dry-running and freeze protection ·Constant discharge pressure
·Automatic flowless sensor ·Less wear of the system during operation
·Automatic recoveryafter powerfailure Inverter ·Compact assemblyand installation
·Pump protection
·FND-Status monitoring O
Applications
·Pressure boosting systems Domestic water supply systems ·Cooling systems ·Air-conditioning systems ·Small industrial water supply systems ·Horticultural irrigation systems
Specification
·Max.Flow(Q):48m³/h
·Max.Head(H):44m
·No.of pumps:Up to 2 pumps (Please contact the office for 3 pumps)
·Input Power:3PH380V\~440V/60Hz (1\~3HP)
Functions
·Control Mode-Pressure/differential pressure
·Set the setting pressure
·Dry-running and freeze protection
·Automatic flowless sensor
·Automaticrecoveryafter power failure Inverter
·Pump protection
·FND-Status monitoring
·Equipped with a RS485-Optional
NSQP-2DHMSeries
NSQP-2DHM series is built on the basis of DHM pumps. Themaindifferencebetween the DHMand the NSQP-2DHMseries is thevariable frequency drive.Enhanced with the NSQ-Drive, NSQP-2DHMserieswith theappropriate sensor is turned into an intellgent,variable speed pumping system.The NSQ-Drives adjust the motor speed which in turn provides constant pressure or differential pressure to the flowrate. NSQP-2DHM series isalso equipped with the7" touchscreen monitor that isembedded into the panel which features the latest GUl.
Applications
·Pressure boosting systems ·Domestic water supply systems ·Cooling systems ·Air-conditioning systems ·Small industrial watersupplysystems ·Horticultural irrigationsystems
5
Features
7"colorLCDtouchmonitor
·Each pump is individually controlled bya NSQdrive
·Highreliability (Multi-mastercontrol)
·Constant discharge pressure
·Reduced tankand panel sizes
·Less wear of the system during operation
·Compact assembly and installation
·Alternative Operation
-Alternativeoperationreferstothe total sumof the poweraccumulated - This in-return ensures that the operating of each pump will be the same and extends the life-line of each pumpas the wear is evenly distributed amongst the pumps.
Specification
Max.Flow(Q):48m/h
·Max.Head(H):44m
·No.of pumps:Up to 2 pumps (Please contact the office for 3 pumps)
·InputPower:3PH380V\~440V/60Hz (1\~3HP)
NSQ-2DHMSeries
NSQ-2DHM series is built on the basis of DHM pumps.The main differencebetweentheDHMandtheNSQ-2DHMseriesisthe variable frequency drive.Enhanced with the NSQ-Drive,NSQ-2DHM serieswith theappropriate sensor is turned intoan inteligent,variable speed pumping system.The NSQ-Drives adjust the motor speed which in turn provides constant pressure or differential pressure to the flow rate.
Functions
·Control Mode-Pressure/differential pressure
·Set the setting pressure
·Dry-runningand freeze protection
·Automatic flowless sensor
·Automaticrecoveryafterpower failure Inverter
·Pump protection
·FND- Status monitoring
Features
Each pumpis individually controlled bya NSQdrive ·Highreliability (Multi-mastercontrol) ·Constant discharge pressure ·Reduced tank and panel sizes ·Less wear of the system during operation ·Compact assembly and installation
Applications
·Pressure boosting systems ·Domestic water supply systems ·Cooling systems ·Air-conditioning systems ·Smallindustrial watersupplysystems ·Horticultural irrigation systems
·AlternativeOperation
-Alternativeoperationrefersto the total sum of the power accumulated - This in-return ensures that the operating of each pump will be the same and extends the life-line of each pumpas thewear isevenlydistributed amongst the pumps.
Specification
·Max.Flow(Q):48m³/h
·Max.Head(H):44m
·No.of pumps: Up to 2 pumps
·InputPower:1PH200V\~230V/60Hz (1\~3HP)
SQ2-2DHM Series
SQ2-2DHMseriesisbuiltonthebasisofDHMpumps.Themain differencebetweentheDHMandtheSQ2-2DHMseriesisthevariable frequencydrive.Enhancedwith the SQ2-Drive,SQ2-2DHMseries with the appropriate sensor is turned intoan intelligent,variable speed pumping system.The SQ2-Drives adjust the motor speed which in turn providesconstant pressureordifferential pressure to the flowrate.
Functions
·ControlMode-Pressure/differential pressure
·Set the setting pressure
·Dry-running and freeze protection
·Automatic flowlesssensor
·Automatic recoveryafter power failure Inverter
·Pump protection
·FND-Status monitoring
Features
·Each pumpis individually controlledbya SQ2drive ●Highreliability (Multi-mastercontrol) ·Constant discharge pressure ·Less wearof the system during operation ·Compactassemblyand installation
Applications
·Pressure boosting systems ·Domestic water supply systems ·Cooling systems ·Air-conditioning systems ·Smallidustrial water supply systems ·Horticultural irrigation systems
Specification
NSQ-DHMSeries
Applications
·Pressure boosting systems ·Domestic water supply systems ·Cooling systems ·Air-conditioning systems ·Smallindustrial watersupply systems ·Horticultural irrigationsystems
Specification
·Max.Flow(Q):24m/h
·Max.Head(H):44m
·Motor Power:0.75\~2.2kW(1\~3HP)
·InputPower:1PH200V\~230V/60Hz(1\~3HP)
SQ2-DHM Series
SQ2-DHM series is built on the basis of DHM pumps.The main differencebetweentheDHMandtheSQ2-DHMseriesisthe variable frequencydrive.Enhanced with theSQ2-Drive,SQ2-DHMseries withtheappropriatesensor is turned intoan intelligent, variablespeed pumping system.The SQ2-Drive adjust the motor speed which in turn provides constant pressure or differential pressure to the flowrate.
Functions
·Control Mode-Pressure/differential pressure
·Set the setting pressure
·Dry-runningand freeze protection
·Automatic flowless sensor
·Automatic recoveryafter power failure Inverter
·Pump protection
·FND-Status monitoring
Features
Eachpump is individuallycontrolledbya SQ2 drive ●High reliability (Multi-master control) ·Constantdischarge pressure ·Less wear of the system during operation ·Compactassemblyand installation
Applications
·Pressure boosting systems ·Domestic water supply systems ·Cooling systems ·Air-conditioning systems ·Small idustrial water supply systems ·Horticultural irrigationsystems
ModelFeatures
| Model | PowerSpecifications | Numberof Pumps | LCD Touch Panel | ||
| 1PH200V~230V 60Hz (0.5~3HP) | 3PH380V~440V 60Hz (0.75~10HP) | 2 | 3 | ||
| NSQ-2DHF(T) Series | X | Special order | × | ||
| NSQP-2DHF(T) Series | X | Special order | |||
| SQ2-2DHF(T)Series | X | X | |||
ModelFeatures
| Model | PowerSpecifications | NumberofPumps | LCD Touch Panel | ||
| 1PH200V~230V 60Hz (1~3HP) | 3PH380V~440V 60Hz (1~3HP) | 2 | 3 | ||
| 2NSQ Series | X | Special order | × | ||
| 2NSQP Series | Special order | ||||
| 2SQ2 Series | X | X | X | ||
dooch O
XR,XRL pumpsare vertical non-self primingmultistage centrifugal pump of in-line design,which is driven by a standardelectricmotor.Themotoroutputshaftdirectly connectswith the pump shaft througha coupling.The pressure-resistant cylinderand flow passage components are fixed between the pump head and the pump casing bymeansof staybolts.Thepumpcasinghassuctionand discharge ports on the same level (in-line).
All pumpsare equipped with a cartridge mechanical seal foreasymaintenance.
XR,XRL pumpsareavailable in various sizesand various numbers of stage to provide the required flowand pressure. Thepumps are available with DOOCH variable frequency drive (XQ/NSQ Drive).
DefinitionofModel
XR(L)32-4-2 The number of small impellers The number of impellers(Total) Rated flow ( m ^ { 3 } / \hslash ) (204号 Pump Type : Vertical multistage pump XR:Cast iron pump casing XRL:Stainless steel pump casing
5
Motor
IEC-Standard squirrel-cagerotor3phaseelectricmotor
Motor type:TEFC
Protection class:IP54\~55
Insulation class:F
Standardvoltage:7.5kWandbelow-3x220/380V 11kWandabove-3x380V (The standard voltage can be changed asper request.)
Operation Conditions
·Available liquids:
Thin,clean,non-flammableand non-explosive liquid containingno solid granulesand fibers.
·Liquid temperature:Normal temperature : - 1 5 c - + 7 0 c Hotwatertype + 7 0 0 c ~ + 1 2 0 0 c
·Ambienttemperature \because upto + 4 0 ^ { \circ } { c } (204号
·Altitude:upto1000m
Application
The pumpsare suitable for liquid transfer in
- Water supply systems
-Washing systems
- Cooling and air conditioning systems
-Water treatment systems
- Fire fighting systems
- Industrial plants
- Boiler feed systems
| NO. | PARTS | MATERIAL | EN/DIN | AISI/ASTM |
| Motorbracket | GCD450 | EN-GJS-450 | A536-65-45 | |
| 2 | Pumphead(XR) | GC250 | EN-GJS-250C | A48-CL35 |
| Pumphead(XRL) | ||||
| 3 | Mechanical seal | SIC/CARBON/VITON | ||
| 4 | Topdiffuser | STS304 | EN100881,4301 | A240-304 |
| 5 | Diffuser | STS304 | EN10088 1,4301 | A240-304 |
| 6 | Supportdiffuser | STS304 | EN100881,4301 | A240-304 |
| 7 | Inducer | STS304 | EN100881,4301 | A240-304 |
| 8 | Pumpcasing(XR) | GC250 | EN-GJS-250C | A48-CL35 |
| Pumpcasing(XRL) | ||||
| 9 | Baseplate | GC250 | EN-GJS-250C | A48-CL35 |
| 10 | Impeller | STS304 | EN100881,4301 | A240-304 |
| 11 | Shaft | STS304 | EN100881,4301 | A276-304 |
| 12 | Impellersleeve | STS304 | EN100881,4301 | A240-304 |
| 13 | Cylinder | STS304 | EN100881,4301 | A240-304 |
| 14 | Coupling | GCD450 | EN-GJS-450 | A536-65-45 |
| Rubber part | EPDM |
| NO. | PARTS | MATERIAL | EN/DIN | AISI/ASTM |
| 1 | Motorbracket | GCD450 | EN-GJS-450 | A536-65-45 |
| 2 | Pumphead(XR) | GC250 | EN-GJS-250C | A48-CL35 |
| Pumphead(XRL) | SSC13 | EN102831,4408 | A351-CF8 | |
| 3 | Mechanical seal | SIC/CARBON/VITON | ||
| 4 | Topdiffuser | STS304 | EN100881,4301 | A240-304 |
| 5 | Supportdiffuser | STS304 | EN100881,4301 | A240-304 |
| 6 | Diffuser | STS304 | EN100881,4301 | A240-304 |
| 7 | Inducer | STS304 | EN100881,4301 | A240-304 |
| 8 | Pumpcasing(XR) | GC250 | EN-GJS-250C | A48-CL35 |
| Pumpcasing(XRL) | SSC13 | EN102831,4408 | A351-CF8 | |
| 9 | Baseplate | GC250 | EN-GJS-250C | A48-CL35 |
| 10 | Impeller | STS304 | EN100881,4301 | A240-304 |
| 11 | Shaft | STS304 | EN100881,4301 | A276-304 |
| 12 | Intermediatebearing | Tungsten carbide | ||
| 13 | Cylinder | STS304 | EN100881,4301 | A240-304 |
| 14 | Bottombearing | Tungsten carbide | ||
| 15 | Coupling | GCD450 | EN-GJS-450 | A536-65-45 |
| Rubberpart | EPDM |
| NO. | PARTS | MATERIAL | EN/DIN | AISI/ASTM |
| 1 | Motorbracket | GCD500 | EN-GJS-500 | A536-70-50 |
| 2 | Pumphead(XR) | GCD500 | EN-GJS-500-7C | A536-70-50-05 |
| Pumphead(XRL) | SSC13 | EN102831,4408 | A351-CF8 | |
| 3 | Mechanical seal | SIC/CARBON/VITON | ||
| 4 | Topdiffuser | STS304 | EN100881,4301 | A240-304 |
| 5 | Supportdiffuser | STS304 | EN100881,4301 | A240-304 |
| 6 | Diffuser | STS304 | EN100881,401 | A240-304 |
| 7 | Inducer | STS304 | EN100881,4301 | A240-304 |
| 8 | Pumpcasing(XR) | GCD500 | EN-GJS-500-7C | A536-70-50-05 |
| Pumpcasing(XRL) | SSC13 | EN102831,4408 | A351-CF8 | |
| 9 | Baseplate | GCD500 | EN-GJS-500 | A536-70-50 |
| 10 | Impeller | STS304 | EN100881,4301 | A240-304 |
| 11 | Shaft | STS304 | EN100881,4301 | A276-304 |
| 12 | Intermediate bearing | Tungstencarbide | ||
| 13 | Cylinder | STS304 | EN100881,401 | A240-304 |
| 14 | Coupling | GCD450 | EN-GJS-450 | A536-65-45 |
| Rubber part | EPDM |
Specification
| DESCRIPTION | XR(L)1 XR(L)3 XR(L)5XR(L)1OXR(L)15XR(L)2OXR(L)32XR(L)45XR(L)64XR(L)95XR(L)125XR(L)155XR(L)185 | ||||||||||||
| Rated flow [m³/h] | 1 | 3 | 5 | 10 | 15 | 20 | 32 | 45 | 64 | 95 | 125 | 155 | 185 |
| Flow range [m³/h] | 0.8-2.9 | 1.4-5.4 | 3-10.2 | 6-16 | 10-29 | 12-35 | 18-48 | 25-72 | 36-10855.5-150 | 75-190 | 90-240 | 110-290 | |
| Max.pressure [bar] | 25 | 30 | 40 | ||||||||||
| Motor power [kW] | 0.75-3.70.75-3.70.75-7.51.5-113.7-18.53.7-18.5 | 5.5-30 | 5.5-45 | 7.5-45 | 11-55 | 15-110 | 18.5-110 | 30-132 | |||||
| Liquid Temperature['c] | -15~+120℃ | ||||||||||||
| Ambient Temperature['℃c] | Max.40℃ | ||||||||||||
| Pump Type | Vertical Multistage Centrifugal Pump | ||||||||||||
| XR | . | · | . | · | |||||||||
| XRL | · | · | · | · | |||||||||
| DIN Flange | DN25 | DN25 | DN32 | DN40 | DN50 | DN50 | DN65 | DN80 | DN100 | DN100 | DN150 | DN150 | DN200 |
| MODEL | POWER | DIMENSION(UNIT:mm) | WEIGHT (kg) | |||||
| kW | HP | B1 | B2 | B1+B2 | D1 | D2 | ||
| XR(L) 1-9 | 0.75 | 1 | 474.5 | 255 | 729.5 | 170 | 160 | 26 |
| XR(L)1-13 | 1.5 | 2 | 546.5 | 315 | 861.5 | 187 | 170 | 30 |
| XR(L) 1-17 | 1.5 | 2 | 618.5 | 315 | 933.5 | 187 | 170 | 38 |
| XR(L)1-25 | 2.2 | 3 | 762.5 | 315 | 1077.5 | 187 | 170 | 42 |
| XR(L) 1-27 | 3.7 | 5 | 798.5 | 330 | 1128.5 | 227 | 220 | 45 |
| MODEL | POWER | DIMENSION(UNIT:mm) | WEIGHT (kg) | |||||
| kW | HP | B1 | B2 | B1+B2 | D1 | D2 | ||
| XR(L)3-4 | 0.75 | 1 | 384.5 | 255 | 639.5 | 170 | 160 | 22 |
| XR(L) 3-5 | 0.75 | 1 | 402.5 | 255 | 657.5 | 170 | 160 | 24 |
| XR(L)3-8 | 1.5 | 2 | 456.5 | 315 | 771.5 | 187 | 170 | 28 |
| XR(L)3-11 | 1.5 | 2 | 510.5 | 315 | 825.5 | 187 | 170 | 35 |
| XR(L)3-13 | 2.2 | 3 | 546.5 | 315 | 861.5 | 187 | 170 | 37 |
| XR(L)3-17 | 2.2 | 3 | 618.5 | 315 | 933.5 | 187 | 170 | 38 |
| XR(L)3-19 | 3.7 | 5 | 654.5 | 330 | 984.5 | 227 | 220 | 46 |
| XR(L) 3-21 | 3.7 | 5 | 690.5 | 330 | 1020.5 | 227 | 220 | 46 |
| XR(L)3-23 | 3.7 | 5 | 726.5 | 330 | 1056.5 | 227 | 220 | 47 |
| XR(L)3-25 | 3.7 | 5 | 762.5 | 330 | 1092.5 | 227 | 220 | 57 |
| MODEL | POWER | DIMENSION(UNIT:mm) | WEIGHT (kg) | |||||
| kW | HP | B1 | B2 | B1+B2 | D1 | D2 | ||
| XR(L)5-2 | 0.75 | 1 | 366.5 | 255 | 621.5 | 170 | 160 | 21 |
| XR(L)5-4 | 1.5 | 2 | 420.5 | 315 | 735.5 | 187 | 170 | 27 |
| XR(L) 5-5 | 1.5 | 2 | 447.5 | 315 | 762.5 | 187 | 170 | 34 |
| XR(L)5-7 | 2.2 | 3 | 501.5 | 315 | 816.5 | 187 | 170 | 35 |
| XR(L)5-9 | 2.2 | 3 | 555.5 | 315 | 870.5 | 187 | 170 | 37 |
| XR(L)5-12 | 3.7 | 5 | 636.5 | 330 | 966.5 | 227 | 220 | 45 |
| XR(L)5-14 | 3.7 | 5 | 690.5 | 330 | 1020.5 | 227 | 220 | 55 |
| XR(L)5-16 | 3.7 | 5 | 744.5 | 330 | 1074.5 | 227 | 220 | 56 |
| XR(L)5-20 | 5.5 | 7.5 | 882.5 | 365 | 1247.5 | 268 | 245 | 72 |
| XR(L)5-22 | 5.5 | 7.5 | 936.5 | 365 | 1301.5 | 268 | 245 | 73 |
| XR(L)5-24 | 7.5 | 10 | 990.5 | 365 | 1355.5 | 268 | 245 | 86 |
| MODEL | POWER | DIMENSION(UNIT:mm) | WEIGHT (kg) | |||||
| kW | HP | B1 | B2 | B1+B2 | D1 | D2 | ||
| XR(L)10-2 | 1.5 | 2 | 433 | 315 | 748 | 187 | 170 | 44 |
| XR(L)10-3 | 2.2 | 3 | 463 | 315 | 778 | 187 | 170 | 45 |
| XR(L) 10-5 | 3.7 | 5 | 523 | 330 | 853 | 227 | 220 | 54 |
| XR(L)10-6 | 3.7 | 5 | 553 | 330 | 883 | 227 | 220 | 64 |
| XR(L)10-8 | 5.5 | 7.5 | 633 | 365 | 998 | 268 | 245 | 86 |
| XR(L)10-9 | 5.5 | 7.5 | 663 | 365 | 1028 | 268 | 245 | 87 |
| XR(L)10-12 | 7.5 | 10 | 753 | 365 | 1118 | 268 | 245 | 101 |
| XR(L) 10-14 | 11 | 15 | 843 | 480 | 1323 | 318 | 290 | 144 |
| XR(L) 10-17 | 11 | 15 | 933 | 480 | 1413 | 318 | 290 | 148 |