Energy Saving Pump solutions for a better future 50Hz
dooch MainProductions
XQP SERIES
IndividualVFDBoosterPumpSystem
Max.Flow(Q):1440m³/h
Max.Head(H):245m
MotorPower:0.75\~22kW(1\~30HP)
IndividualVFDBoosterPumpSystem
NSQ SERIES
Max.Flow(Q):720m³/h
Max.Head (H):245m
MotorPower:0.75\~22kW(1\~30HP)
Max.Flow(Q):1440m³/h
N747D SERIES
InverterwithinPanelBoosterPump
Max.Flow(Q):1440m³/h Max.Head(H):330m MotorPower:0.75\~110kW(1\~150HP)
SQ-2DHM SERIES
Built-InVFDHorizontalBoosterPump
Max.Flow(Q):36m³/h
Max.Head(H):29m
MotorPower:0.75\~1.1kW(1\~1.5HP)
NSQ-DHF(T) SERIESBuil-InVFDMulti-stageHorzontalPump
Max.Flow(Q):29m/h
Max.Head(H):68m
MotorPower:0.55\~5.5kW(0.75\~7.5HP)
NSQP-DHF(T) SERIES
BuiltHnVFDHorizontal BoosterPumpSystem
Max.Flow(Q):58m³/h
Max.Head (H):68m
MotorPower:0.55\~5.5kW(0.75\~7.5HP)
SQ-DHM SERIES
Built-ln VFD Horizontal Unistage Pump
Max.Flow(Q):18m³/h
Max.Head (H):29m
MotorPower:0.75\~1.1kW(1\~1.5HP)
NDS SERIES
SubmersibleDrainageandSewagePump
Max.Flow(Q):31m³/h Max.Head(H):20.7m MotorPower:0.4\~1.5kW(0.5\~2HP)
XRF SERIES
Multi-Stage VerticalPump
Max.Flow(Q):335m³/hMax.Head(H):360mMotorPower:1.5\~200kW(2\~270HP)
NSQ-XR(L)SERIES
Built-lnInverterMulti-stageVerticalPump
Max.Flow(Q):240m³/h Max.Head(H):245m MotorPower:0.75\~22kW(1\~30HP)
DPC SERIES
HotWaterCirculatingPump
Max.Flow(Q):21m/hMax.Head (H):17.5mMotorPower:40\~750W
NSQ-DPSERIES
Built-lnVFDInHineCirculationPump
Max.Flow(Q):480m³/h Max.Head(H):83m MotorPower:0.75\~22kW (1\~30HP)
NDPS SERIES SewagePackageSystem
Max.Flow(Q):96m³/hMax.Head(H):14mMotorPower:1.5\~11kW(2\~15HP)
dooch
dooch HISTORYOFCOMPANY
Doochtakesprideinbeingrecognizedaspioneersinthemanufacturingof \mathbb { m } \mathbb { o } \mathbb { o } stainlesssteelwater pumpsandVFD.Weprioritizetheessentials,focusingonproducing thehighest qualityandmost energy-efficientpumps.
1996.05·Established Dooch Co.,Ltd. 2004.04·ObtainedtheEnergy 2006.01·ObtainedtheNEWTechnology 2007.11·Re-locatedthe HQ in Incheon EfficientCertification VenturedCompanyCertification (Gyeonggi-do Hwaseong) 2004.11·DevelopedthefirstVFD 2006.08·ObtainedtheNEWEXCELLENT (Q-Drive) PRODUCT(NEP)Certification (IQ-Booster Pump) 眉 Q □ NeR 房 NEP
1996 眉 2008.06·Designedasoneof the promisingexportcompanies 2002.03mt 2005.04sioo 2008.12
2023 2005.11·Established Dooch's Militarymanpoweradministration TechnologyR&Dcenter 2009.09·Selectedasone of the promising
2023.02ederes) dooch cempaniesin theGyeonggi-do
2023.03·Establishedthe2ndfactory inChina(Huzhou) 2010.06?General ServicesAdministration
2023.04·ObtainedtheNew Excellent topproductcertification Product Certification(FSSerise) 2011.12·Rewardedthe1million
2022.11·ObtainedEPC(ExcellentPerformanceCertificate) dollarexporttrophy fromKoreaMinistryofSMEsandStartups (FSSerise)
2021.06·CertificateofKoreaGovernment2017.01·LaunchedtheOnepumpcontrollr (IOP-IRt BooduertPump) 217.03O 2015.03Ecien heade 2013.03 7501forSmall volutepump ·EstablishedShanghai procurementservice
210 217 ·LaunchedtheTM3.5 2015.09·Developed themultistage
2020.10·DevelopedFireFightingSystem 2017.08·ObtainedtheIP55CEcertificate Turbinepumps (FSSeries) forptpae NDS-03V(B)-M(A) 馋 Submersiblepumps 2017.11·Developed Hot Water Circulation Pump (DPC) NEP 丕旨早个 国 CE !
2019.07·DevelopedTouchMonitor10" 2018.02·Developed HouseholdPump 2016.03·VerticalMulti-StagePumps 2014.08·ReleasedthePremium (TM10.1) (DA) (DRL-XRLseries) Booster PumpSystem (XQPseries) 2018.03·Developed Self-Priming Pump VED(NtS-XQ·NQ-Drive) -XM7rive 2018.08·Developed Vertical 2016.05·Established the 2nd 2014.11·Obtainedthe Multistage Pump(XR) factoryin Hwaseong-si GOODDESIGNreward -XQPBoosterPumpSystem 2016.07·Submersible PumpKSCertified 2016.08?Appliedthe3yearswarrantypolicy
dooch
" Dooch standsat the forefront of the global pump industry. In essence,we provide our customers with the most cutting-edge and energy-efficient solutions available worldwide."
R&DCenter
Dooch,a renowned Korean manufacturer of premium water pumps with Variable Frequency Drivers, is committed to advancing water management.Our R&D center focuses on innovating pump-specific Variable Frequency Drivers and controllers,contributing to comprehensive solutions for water supply, sewage liftingstations,andadvancedfirefightingpumpsystems.
20052772 # The R&D Center Certified by
Korea Industrial Technology Association #
PrimaryDevelopmentResult
Korean language LCD-boostercontroller(747D)
Exclusive inverter for the pump.(Q-Drive):1HP\~30HP
Inverterconnected pipe (EQ-Drive)
Pumpsystembuilt-inindividual inverter(IQP)
Multi-inverter for booster system (MQ-Drive)
Single phrase inverter forsmallerpumps(SQ-Drive)
Remote control system forbooster pump (IM-2000)
Premium inverter for pumps (XQ-Drive)
Exclusive inverter for pumps(NSQ-Drive)
Touch LCD Monitor (TM7.0")
One pump controller (OPC-1000,1001)
3 . 5 " Colordisplay for inverter(TM3.5")
Inverter-specific Touch LCD Monitor (TM10.1")
Touch LCD Monitor for fire-fighting (TM10.1")
Certification
Certificate of Korea Government Excellent products
Certificate of performance
HighEfficiency Material
CE certification
KS certification
ISO certification
KC hygiene safety certification
KC Electrical equipment safety certification
23 patents
20Design patents,18 trademark rights
FeaturesoftheQ-Drive
Applications
-Saves energy up to 5 0 % (204号 -Suitable for variousapplications - Built-in pump protection functions -Convenient installation and user friendly - Booster pump - Heating Circulation pump - Submersible pump - Centrifugal Pump
Boosterpumpbuilt-inindividualinverter In-linepumpbuilt-ininverter
-Allpumpsare fittedwithan intergrated variable frequency drives.
- Up to 6 electronically speed-controlled pumps. - High reliability.
- New excellent product, Certificate of performance - In-line pump fitted with an integrated variable frequency drive.
- Suitable forvarious applications
and saves the energy up to 50 %
- Up to22kW
ProductRangeDescription
PerformanceCurve
The following figure shows the temperature according tomin.flowandratedflow
1.Curve tolerance in conformity with ISO9906 Annex A
2.All curves are based on the measurement byDOOCHstandardmotor
3.Measurement is done within 2 0 % air-free water,kinematicviscosityof1mm²/sec
4.The operation of the pump shall refer to the performancerange indicatedbythethickened curvetoavoidoverheatdue tothelow flow rate or overload of motor due to the large flow rate.
PumpSelections
Selectionof pump,the followingsshouldbe considered. -Usage (Service)
-Maximum flowand pressure
-Comparison of positive suction head
Efficiency
If the pump always runs at a steady start point,a pump should be selected to meet the max. efficiencypoint and start point.Incase thewater consumption is changed,the pump selection should be reconsideredaccordingtothemax.flowconsumption and the consumption pattern.
Min.InletPressureNPSH
If the pressure in the pump is lower than the steaming pressure,cavitationsmight occur.Toavoid cavitations,a minimum pressureat the inlet side of the pump is required.The max.suction head can refer to thebelow figureand be calculated with the following formula;
{ \sf H } = PaX10.2-NPSH-Hf-Hv-Hs
\mathsf { P b } = atmosphere pressure(bar),the pressure can be set1bar.Inaclosedsystem,Pb meanssystem pressure(bar)
NPSH \mathbf { \tau } = \mathbf { \tau } NetPositiveSuction Head (m),itcanbereadoutfrom thepointof possiblemaxflowrateshownonNPSHcurve
Hf \mathbf { \tau } = \mathbf { \tau } Pipeline lossat the inlet(m)
Hv \mathbf { \tau } = \mathbf { \tau } Steaming pressure(m)
Hs \mathbf { \tau } = \mathbf { \tau } Safetymargin,itmeansminimum O.5mdelivery head
If the calculated result H is positive,the pump may run under the max suction head H. If the calculated result H is negative,a pressure over H is required at the inlet side of the pump.
doooh O
BoosterSystem
DOOCH booster system supplies the constant pressurized water to the residential buildings and high riseoffice buildings,where it is required.
Features
Highreliability
High efficiency
Fully integrated,all-in-onems
Systems tomatch every need and requirement
Easy installation and operation
Applications
·Apartments
·Residential Buildings
· Office Buildings
·Hotels
·Industry
SystemSpecification
| Method of Control | Individual VFD | General Inverter |
| Models | XQP-Series, NSQ(P)-Series | 747D-Series |
| Operation Method | Controlled by a VFD installed on each and every pumps | Controlled by one inverter on one pump |
| Installation | Indoor | |
| Temperature | -10℃~+40℃ | |
| Liquid Type | Clean Water | |
| Liquid Temp. | 0℃~70℃ | |
| Pump | Vertical Multi-stage Pump | |
| No.Of Pumps | 2~6 (NSQ Exception) | |
| Power | 3PH×380V×50Hz 1PH×220V×50Hz (XQP Exception) | 3PH×220/380V×50Hz |
| Inlet/Outlet Manifold | Stainless Steel | |
| MODEL | XQ-Drive | NSQ-Drive | N747D |
| Features | V.F.D. for pumps | V.F.D.for pumps | General inverter in a control panel 怕上网 |
| Specification | MotorPower:0.75~22kW Input:3Φ×380~440V Output:3Φ×380~440V Frequency:50/60Hz | MotorPower:0.75~22kW Input:1Φ×200~230V(0.75~2.2kW) 3Φ×380~440V(0.75~22kW) Output:3Φ×380V Frequency:50/60Hz | MotorPower:0.75~110kW Input:3Φ×220/380V Output:3Φ×380V Frequency: 50/60Hz |
ControlSpecifications/Features
| XQP-Series IndividualInverterBoosterSystem | N747D-Series Single Inverter BoosterSystem | |
| Appearance | ||
| Features | ·All pumps are fitted with an integrated V.F.D.which are directly mounted unto the motor ·Newly designed V.F.D. hardware Puprirangesfrom0.75kW-22kW 2~6 Electronically speed controlled pumps ·Equipped with a7.0" Touch Monitor Lowenergy consumption (Above30kW,747D-Series isrequired) | Control panel isintegratedwitha general inverterwhich controls the pumpswithin the system. Pumpsrangesfrom0.75kW~110kW 26Elecrl ·Constant discharge pressure Lowenergyconsumption Equipped with Dooch's own N747D controller |
| Inverters | V.F.D.for pumps(XQ-Drive) | General Inverter |
| Typeof Manifolds | StandardManifold | Standard Manifold |
| Panel | 國 2LG 7"LCDTouch ScreenMonitor | General Inverter within the Panel |
| NSQP-Series Individual InverterBoosterSystem | NSQ-Series Individual InverterBoosterSystem | ||
| Appearance | |||
| Features | ·All pumps are fitted with an integrated V.F.D.whichare directly mounted unto the motor ·Newly designed V.F.D. hardware (NSQ Drive) ·Pumpsrangesfrom0.75kW~22kW ·2~6 Electronically speed controlled pumps ·Equipped witha7.0"TouchMonitor ·Low energy consumption | ·3.5"Color display(The latest GUl is applied) ·All pumpsare fitted with an integratedV.F.D.whicharedirectly mounted unto the motor ·Newly designed V.F.D. hardware (NSQDrive) ·Pumps ranges from0.75kW~22kW ●2~3 Electronically speed controlled pumps ·Low energy consumption | |
| Inverters | V.F.D.for pumps(NsQ-Drive) | V.F.D.for pumps(NsQ-Drive) | |
| Type of Manifolds | StandardManifold | Standard Manifold | |
| Panel | 國 | 7"LCD Touch Screen Monitor | QO : Side Panel with individual circuit breakers (The latest GUl is applied) |
| XQ-XR(L)Series PremiumV.F.D.Multi-stageVerticalPump | NSQ-XR(L) Series V.F.D.Multi-stage VerticalPump | |
| Appearance | ||
| Features | ·Integrated V.F.D.which are directly mounted unto the motor Newlydesigned V.F.D.hardware (XQDrive) ·Low energy consumption ·Compact Design, no need for additional control panels | IntegratedV.F.D.whicharedirectly mounted unto the motor Newly designed V.F.D.hardware (NSQ Drive) Lowenergyconsumption · Compact Design,no need for additional control panels |
| Inverters | Premium V.F.D.for pumps (XQ-Drive) | R8882 V.F.D. for pumps (NSQ-Drive) |
| Manifolds | Exclusive piping for V.F.D. pumps | Exclusive piping for V.F.D.pumps |
PremiumXQ-Drive
XQ-DRIVES are pump specific variable frequency drive that managespumpperformancetomatchawiderangeofsystem conditionsand requirements.Adjusting the pumpspeed is the most efficient means of controlling pump flow and reducing the energy consumption as the drives are self-cooling and motorindependent structure.Itcanbemounteddirectlyon the motor oron the wall.XQ DRIVES are equipped with the lastest GUI3.5"color LCD display.Anoise filtering EMC filterand a DC reactorarealso installed within the \mathsf { x } \mathsf { α } Drives.
Technical Specification
| AvailablePower | 0.75~22kW |
| Input Power | 3Φ×380V~440V |
| OutputPower | 3Φ×380V~440V |
| Frequency | 50/60Hz |
| Max.Frequency | 60Hz |
| IP Class | IP 55 |
| Max.Distance Of Pressure Transmitter | Max.10m |
| AmbientTemp. | -10℃~+40℃ |
Protections
Dry Running
·Low Water Level Detection
Over/UnderVoltage Inverter
·Min.Flow Stop
·Temp.Pressure Setting
·Sensor Failure
·Pump Freezing
·Pump Overload
XQ-Drive Features
13.5"LCD Display (Graphical User Interface) Energy Savings up to 7 0 % (204号 Multi-pump control capacityof upto 6 pumps Hydraulic control functions included Electrical and hydraulic pump protections Automatic recovery after power failure Easy retrofiting on existing pump system Flexible installation either directly ona standard I.E.C.motors oron walls EMC filter and DC reactor built-in -Reduce noise and harmonic distortion
NSQ-DRlVES are pump specific variable frequency drive that manages pumpperformance tomatchawide range of system conditions and requirements.Adjusting the pump speed is the most efficient means of controlling pump flow and reducing the energy consumption Asthedrives are self-cooling and motor-independent structure, it can be mounted directly on the motor or on the wal.
Technical Specification
Protections
| AvailablePower | 0.4~22kW |
| InputPower | 1Φ×200~230V (0.4~2.2kW) 3Φ×380~440V(0.75~22kW) |
| OutputPower | 3Φ×380V |
| Frequency | 50/60Hz |
| Max.Frequency | 60Hz |
| IP Class | IP55 |
| Max.Distance Of Pressure Transmitter | Max.10m |
| Ambient Temp. | -10℃~+40℃ |
·DryRunning
·Low Water Level Detection
·Over/Under Voltage Inverter
Min.Flow Stop
* Temp. Pressure Setting
·Sensor Failure
·Pump Freezing
·Pump Overload
NSQ-DriveFeatures
Energy Savings up to 7 0 % Multi-pump control capacity of up to 6 pumps Hydraulic control functions included
4Electrical and hydraulic pump protections Automatic recovery after power failure Easy retrofitting on existing pump system Flexible instalation either directlyonastandard I.E.C.motorsoron walls
One Pump ControllerOPC-1000/OPC-1001
One pump controller OPC-1000 and OPC-1001are applicable forany general inverter,and this product enables the latest pump control function of pump inverter.
Sincethisproduct isapplicable forany general inverter,it can be utilized without limitation of pump power.
Also,this product is easy to set-up the pressure and provides various pump protection functions.
| InputPower | 1Φ×200~240V/50~60Hz |
| Communication Port | RS485 communication MOD BUS-RTU CANcommunication (Internal communication) |
| Display | 3.5"TFTTRUECOLORLCD(320×240):OPC-1001 3xLED:OPC-1000 |
| Multi-function Input/Output | RUN/STOP,RESET,EMSTOP,Pressuresesor input(2ea),Low water level sensor,Multi-function digital input(3ea),Multi-functionanalogue input (1ea),RUN/STOP,FAULT relay output, Multi-function analogue output(1ea) |
| ControlSignal | RUN/STOP,RESET,EMSTOP,Analogue signal input, Frequencycommandanalogueoutput RUN/STOP,FAULTrelaysignal |
Properties
·Control for Static pressureand Differential pressure -2 pressure sensor wiringavailable
·Pump control with General inverter available (No limitation for invertercapacity)
Interactive control availableupto6pumps (Maximization ofsystemstability) Pump protection function available (High pressure,Low pressure,and Pressure sensor error) Control parameterset-upvia Keypad (For the case of OPC-10o0,optional item) Log indication for Pump/Inverter operation (Key pad type only)
ColorMonitorTM3.5
TM3.5monitor receives the data from pumps with inverters, and provides the integrated information for user's easy understanding. Also,it iseasy to set the system pressure,and user can understand the various pump information such as pump operation log oralarm log,withuser-friendly UXand GUl.
Specification
| InputPower | 1Φx200~240V/50~60Hz |
| Communication Port | RS485 communication MOD BUS-RTU |
| Display | 3.5"TFTTRUE COLOR LCD(320×240) |
| Multi-function Input/Output | SYSTEM RUN output relay contact SYSTEMFAULToutput relay contact |
| StorageMedium | SD card available (Logging data storage) |
| Update Port | USB×1EA |
dooch BOOSTERPUMPSYSTEM 2016.08.29MON 14:00PM VER.2.0 P1 P2 P3 I 100% 100% 3.2 CURRENT SETTING 4.5 PRESSURE PRESSURE
Properties
·Full color display
·Easy to set the pressure
·Icons includes; History of Run/Alarmand various information
·Languages includes;Korean/Chinese/English
·RS-485: Integrated communicationwith each drive information
·USB PORT:Firmware upgrade port
·Available up to 3 pumps
·Loggingdata records (Setting pressure, Current setting,Operation data of each pump
Features
·Full Color Display
·Touch Screen Interface
·User-Friendly/Easy to function
·Icons includes; History of Run/Alarm and other various information
·Languages include;Korean/Chinese/English
·RS 485: Integrated communication
·USB PORT:Firmware upgrade port
Specification
·7"TFT LCD
·Touch Screen Monitor
·RS-485PORT:2 ports
·CANCOM.PORT:1
·Run/Alarm contact
·Power:220\~440V
·Temp.&Humidity:-10\~40℃/90%Under
·USB PORT
ModelApplication
| Models | Available | Unavailable |
| NSQ-Series | ||
| NSQP-Series | ||
| XQP-Series |
P:IndicatesaTM 7 . 0 " TouchMonitorisincludedwiththesystem
GUI(Graphic User Interface) Introduction
1. Current Date and Time
2.Setting Pressure Value
3.Current Pressure Value
4. Current Output Ratio
5. Icon/Current condition of each pumps (Up to 6 pumps)
| Ratio Current operating ratio | Current Current Value | ||
| Power Current power consumption | Frequency Current operating frequency | ||
| Accumulated Power CurentPower | 00 400 | Output Power Current Output Power |
6. Status
7. Run History
8.Set-Up
NSQ-XR(L)
NSQ-XR(L) pumps are built on the basis of XR(L) pumps. Enhanced with the NSQ-Drive,the \mathsf { X R } ( \mathsf { L } ) (204号 pump together with the appropriate sensor is turned intoan intelligent, variablespeed pumping system. The NSQ-Drivesare frequency converter
Specification
Max.Flow:240m³/h
·Max.Head:245m
·Motor Power:0.75\~22kW(1\~30HP)
·InputPower:3Φ×380V\~440V/50&60Hz 1Φ×200V\~230V/50&60Hz
XR(L)3Series
XR(L)10Series
| [kPa] | XR(L)10 | ||||||||||||||
| 220 | -22 | ||||||||||||||
| 50Hz | |||||||||||||||
| 200 | -20 | ||||||||||||||
| 180 | -18 | ||||||||||||||
| 160 | |||||||||||||||
| -16 | |||||||||||||||
| 140 | |||||||||||||||
| 44 | |||||||||||||||
| 120 | |||||||||||||||
| 12 | |||||||||||||||
| 100 | |||||||||||||||
| 10 | |||||||||||||||
| 80 | 9 | ||||||||||||||
| 60 | -8 | 800 | |||||||||||||
| 7 | |||||||||||||||
| -6 | |||||||||||||||
| 543 | |||||||||||||||
| 400 | |||||||||||||||
| 20 -2 -1 | |||||||||||||||
| 0 0 | |||||||||||||||
| 1Pump | 1 2 3 4 5 6 7 9 | ||||||||||||||
| 2Pump | 8 10 11 12 0 2 4 6 8 10 12 14 16 18 20 22 | 24 Q[m³/h] | |||||||||||||
| 3Pump | 0 3 6 9 12 15 18 21 24 27 30 | 33 36 | |||||||||||||
| 4Pump | 0 4 8 12 16 20 | 40 44 48 | |||||||||||||
| 5Pump | 24 0 5 10 15 20 25 30 | 45 50 55 | |||||||||||||
XR(L) 15 Series
XR(L)95Series
XR(L)125Series
DOOCH booster system supplies constantly-pressurized water to the residential buildings and high rise ofice buildings, where it isrequired.
It is operated at the possibly lowest energy consumption according to thewater supply demand,with controlling the number of pump operation and speed of their motors.
Features
High reliability
High efficiency
Fully integrated,all-in-onetems
Systems to match every need and requirement
Easy installation and operation
Applications
·Apartments
·Residential Buildings
· Office Buildings
·Hotels
·Industry
SystemSpecification
| Method of Control | IndividualVFD |
| Models | NSQ(P)-2DHM,SQ-2H NSQ(P)-2DHF(T), SQ-2DHF(T) |
| Type | VFD installed on each pumps |
| Installation | Indoor |
| Temperature | -10℃~+40℃ |
| Liquid Type | CleanWater |
| Liquid Temp. | 0℃~70C |
| Pump | Horizontal Centrifugal Pumps |
| No.of Pumps | 2 |
| Power | SQ-1PH220V×50Hz NSQ-1PH220V,3PH380V×50Hz |
Defination of Model (DHM series)
| Model | NSQ-Drive | SQ-Drive (1PH) |
| Features | ||
| Specification | Motor Power:0.4~22kW Input:1PH200~230V (0.4~2.2kW) 3PH380~440V (0.75~22kW) Output:3PH220~440V Frequency : 50/60Hz | MotorPower. 0.75~2.2kW Input:1PH200~230V (0.75~2.2kW) Output: 3PH200~230V Frequency : 50/60Hz 7" touch monitoris un-adaptable |
| Model | NSQ-Drive | SQ-Drive (1PH) |
| Features | ||
| Specification | Motor Power:0.4~22kW Input : 1PH 200~230V (0.4~2.2kW) 3PH380~440V (0.75~22KW) Output : 3PH 220~440V Frequency : 50/60Hz | MotorPower:0.75~2.2kW Input: 1PH200~230V (0.75~2.2kW) Output:3PH200~230V Frequency : 50/60Hz 7"touch monitor is un-adaptable |
| NSQ-DHF(T) Series Inverter Horizontal Pump | SQ-DHF(T) Series Inverter Horizontal Pump | |
| Appearance | ||
| Features | ·Equippedwitha NSQ-Drive • High Reliability ·Maintains constant pressure ·Soft start functionality ·Compact Design/easy instalation | Equippedwitha SQ-Drive HighReliability Maintainsconstant pressure ·Softstartfunctionality ·CompactDesign/easy installation |
| Inverters | (NSQ-Drive) | (SQ-Drive) |
| Manifolds | Check Valve | Check Valve |
| NSQP-2DHMSeries IndividualInverterHorizontalBoosterSystem (PremiumModel) | SQ-2DHMSeries IndividualInverterHorizontalBoosterSystem | |
| Appearance | ||
| Features | ·7"LCD touch monitor · All pumps are fitted with an integrated V.F.D.which are directly mounted unto themotor · High reliability ·Communication between pumps | ·All pumpsarefittedwithanintegrated V.F.D.which are directly mounted unto themotor ·High realiability ·Constant discharge pressure ·Lowest energy consumption |
| Inverters | (NSQ-Drive) | (SQ-Drive) |
| Manifolds | StandardManifold | StandardManifold |
| Panel | 7" LCD Touch Screen Monitor |
| NSQ-DHMSeries Inverter HorizontalPump | SQ-DHMSeries Inverter HorizontalPump | |
| Appearance | ||
| Features | ·Equipped with a NSQ-Drive · High Reliability ·Maintains constant pressure ·Soft start functionality ·CompactDesign/easy installation | Equipped witha SQ-Drive High Reliability ·Maintainsconstant pressure ·Softstart functionality ·Compact Design/easy installation |
| Inverters | (NSQ-Drive) | (SQ-Drive) |
| Manifolds | Check Valve | Check Valve |
SQ-Drive
SQ-DRlVE isa single phrase variable frequency drive that manages pump performance tomatchawide range of system conditions and requirements.Adjusting the pump speed is the most efficient means of controlling the pump flow and reducing theenergyconsumption
SQ-Drive isa motor-independent structure, it can be mounted directly on the motor oron the wall.
TechnicalSpecification
| AvailablePower | 0.75~2.2kW |
| InputPower | 1Φ×200~230V |
| OutputPower | 3Φ×200~230V |
| Frequency | 50/60Hz |
| Max.Frequency | 60Hz |
| IP Class | IP 55 |
| Max.Distance Of Pressure Transmitter | Max.10m |
| Ambient Temp. | -10℃~+40°℃ |
SQ-Drive Features
⑥ Standalone inverter fora single pump { x } Hydraulic control functions included \otimes Electrical and hydraulic pump protections \otimes Easy retrofitting on existing pump systems \Theta Flexible installations(motor,wall) ⊚ Small compact design and space saving 7 FND display for easy status monitoring and programing
5
Protections
·DryRunning
* Low Water Level Detection
·Over/Under Voltage Inverter
●Min. Flow Stop
·Temp.Pressure Setting
·Sensor Failure
·Pump Freezing
·Pump Overload