Ex-safety switches
Application area
The explosion-protected installation switches are for use in the Zones 1, 2, 21 and 22.
Product features
.Full AC-3 switching capacity.
: Isolating properties according to EN 60947-4-1 with compulsory opening of the main current contacts.
.EMERGENCY STOP version is also available.
. Installation-friendly design and easily accessible connection terminals.
: Protected against inadvertent switching on by the integrated locking facility.
GHG 26 switches (10-180 A) and are now confirmed to comply with the new standard IEC 62626-1, requirements Class 1.
The standard divides products into two classifications: Class 0 for general use and Class 1 for harsh and rough/heavy duty conditions.
All products installed in ATEX/IECEx hazardous areas should be rated for Class 1. Class 1 requirements include minimum ratings for mechanical strength, IP protection, tamper resistance, heat/vibration/corrosion resistance, switching capacity, and locking capability
Ex-safety switch 10 A
Technical data
| EC-type examination certificate | BVS 16 ATEX E 079 |
| GB-certification of conformity | cCC |
| Marking acc. to ATEX | @x> ll 2 G Ex de lIC T6 /@x> Il 2 D lP66 T 80*C |
| Marking acc. to IECEx | Ex eb db I T6 Gb Ex tb lI T80*C Db |
| Application temperature | IECEx BVS 16.0045 -20°C+40°c' |
| Rated voltage | Up to max. 500V |
| Rated current | Max.10A |
| Frequency | 50/60Hz |
| Rated making-/breaking capacity AC-3 U 230V | 10A |
| U 400V Ue 500V Back-up fuse | 10A 10A |
| up to 400V up to 500V | Up to 20A gL |
| Main contact | Up to 16A gL 2x1.5-2.5mm2 |
| Auxiliary-/signal contact | 2x0.5-2.5mm2 |
| Degree of protection | IP66 acc. to EN 60529 |
| Insulation class | 1 |
| Cable glands/enclosure drilling | M20(d=5-13mm) |
| Weight | M25(d=8-17mm) |
| Enclosure material | Approx. 0.55kg Polyamide |
| Enclosure colour | Black |
| Auxiliary contact | 1x NO, making-lagging: breaking-leading |
| Padlocking | Can be locked in OFF position with 3 commercially available padlocks |
Ex-safety switch 10 A
Ordering information
| Version | Cable entry | Order No. |
| 3-pole | 2xM25/1xM20 | GHG 261 0005 R0009 |
| 3-pole | 2xM20 | GHG 261 0005 R0005 |
| 3-pole EMERGENCY STOP | 2xm25/1xM20 | GHG 261 0005 R0010 |
| 3-pole | 2xM20 metal entries | GHG 261 0005 R9026 |
Accessories
| Type | Application | Fixing method | Order No. |
| 1 | wall mounting | screw-on | GHG 610 1953 R0101 |
| pipe mounting | screw-on | GHG 610 1953 R0102 | |
| 1 | trelis mounting | screw-on | GHG 610 1953 R0103 |
Dimension
Ex-safety switch 20 A
Technical data
| EC-type examination certificate |
| GB-certification of conformity |
| Marking acc. to ATEX |
| Marking acc. to IECEx |
| Application temperature |
| Rated voltage |
| Rated current |
| Frequency |
| Rated making-/breaking capacity AC-3 |
| U 230V |
| U 400V |
| U. 500V |
| Ue 690V |
| Back-up fuse |
| up to 400V AC |
| up to 500V AC |
| up to 690V AC |
| Main contact |
| Auxiliary-/signal contact |
| Degree of protection |
| Insulation class Cable glands/enclosure drilling |
| Weight |
| 3-pole |
| 6-pole |
| Enclosure material |
| Enclosure colour |
| Auxiliary contact |
| Padlocking |
| BVS19 ATEX E 048X |
| CCC |
| X> II2 G Ex db eb ia IB/lIC T6/T5 Gb /@> II 2 D Ex tb IIIC T80*C Db |
| Ex eb db ia B/lC T6 / T5 Gb |
| Ex tb IIIC T80°C Db |
| IECEx BVS 19.0042X |
| -20°C+40°c" |
| Up to 690V |
| Up to 20A |
| 50/60Hz |
| 20A 20A |
| 10A |
| 10A |
| Up to 35A gL |
| Up to 35A gL |
| Up to 25A gL |
| 2x4mm2 2x0.5-2.5mm2 |
| IP66 acc. to EN 60529 |
| / |
| M20(d=5-13mm) |
| M25(d=8-17mm) M32(d=12-21mm) |
| Option: metal flange with thread |
| Approx. 1.48kg |
| Approx. 2.43kg |
| Glass-fibre reinforced polyester |
| Black |
| 1 x NO making - lagging; breaking - leading |
| 1 NC (only 6-pole version) making-leading: breaking-lagging |
| Can be locked in OFF position with 3 commercially available padlocks |
Ex-safety switch 20 A
Ordering information
| Version | *y contuct(io7 Cable entry | Order No. |
| 3-pole | 2xM32/1xM25 | GHG 262 2301 R0001 |
| 3-pole EMERGENCY STOP | 2xM32/1xM25 | GHG 262 2301 R0002 |
| 3-pole | 2xM20 metal entries | GHG262 2301 R9179 |
| Safety switch 20 A 4-pole with 2 auxiliary contacts (1 x NO; 1 x NC) | ||
| Version | Cable entry | Order No. |
| 4-pole | 2xM20 | GHG 262 2301 R0007 |
| 4-pole EMERGENCY STOP | 2xM32/1xM25 | GHG 262 2301 R0010 |
| 4-pole | 2xM20 metal entries | GHG262 2301 R9228 |
| Safety switch 20 A 6-pole with 2 auxiliary contacts (1 x NO, 1 x NC) | ||
| Version | Cable entry | Order No. |
| 6-pole | 4xM32/1xM25 | GHG 262 2601 R0001 |
| 6-pole | 4xM25 | GHG 262 2601 RO005 |
| 6-pole EMERGENCY STOP | 4xM32/1xM25 | GHG 262 2601 R0002 |
Accessories
| Type | Application | Fixing method | Order No. |
| 2 | wall mounting | snap-on | GHG 610 1953 R0104 |
| 2 | pipe mounting | snap-on | GHG 610 1953 R0105 |
| 2 | trellis mounting | snap-on | GHG 610 1953 R0106 |
| Type | Application | Fixing method | Order No. |
| 3 | wall mounting | snap-on | GHG 610 1953 R0118 |
| 3 | pipe mounting | snap-on | GHG 610 1953 R0110 |
| trellis mounting | snap-on | GHG 610 1953 R0118 |
Dimension
Ex-safety switch 40 A
Technical data
| EC-type examination certificate |
| GB-certification of conformity |
| Marking acc. to ATEX |
| Marking acc. to IECEx |
| Application temperature |
| Rated voltage |
| Rated current |
| Frequency |
| Rated making-/breaking capacity AC-3 |
| U 230V |
| U 400v |
| Ue 500V |
| U 690V |
| Back-up fuse |
| up to 400V AC up to 500V AC |
| up to 690V AC |
| Main contact |
| Auxiliary-/signal contact |
| Degree of protection |
| Insulation class |
| Cable glands/enclosure drilling |
| Weight 3-pole |
| 4-pole |
| 6-pole |
| Enclosure material |
| Enclosure colour |
| Auxiliary contact |
| Padlocking |
| BVS19 ATEX E 059X |
| CCC |
| X> I 2 G Ex db eb ia IC/lIB T6/T5 Gb/x> II2D Ex tb IIC T80°C Db |
| Ex eb db ia IIB/IIC T6 / T5 Gb |
| Ex tb lI T80°C Db |
| IECEx BVS 19.0054X |
| -20°C+40°c" |
| Up to 690V |
| Up to 40A |
| 50/60Hz |
| 40A |
| 40A |
| 40A 32A |
| Up to 80A gL |
| Up to 80A gL |
| Up to 63A gL |
| 2x16mm2 |
| 2x4mm2 |
| IP66 acc. to EN 60529 |
| 1 |
| M25(d=8-17mm) |
| M40(d=16-28mm) |
| Option: metal flange with thread |
| Approx.2.3kg |
| Approx. 2.75kg |
| Approx. 6.50kg |
| Glass-fibre reinforced polyester |
| Black |
| 1 x NO making- lagging: breaking- leading |
| 1 NC (only 6-pole version) making-leading; breaking-lagging |
| Can be locked in OFF position with 3 commercially available padlocks |
Ex-safety switch 40 A
Ordering information
| Safety switch 40 A 3-pole with 1 auxiliary contact (NO) | ||
| Version | Cable entry | Order No. |
| 3-pole | 2xM40/1xM25 | GHG 263 2301 R0001 |
| 3-pole EMERGENCY STOP | 2xM40/1xM25 | GHG 263 2301 R0002 |
| 3-pole | 1xM20 + 2xM25 metal entries | GHG263 2301 R9051 |
| Safety switch 40 A 4-pole with 2 auxiliary contacts (1 x NO; 1 x NC) | ||
| Version | Cable entry | Order No. |
| 4-pole | 2xM25 | GHG 263 2301 R0007 |
| Safety switch 40 A 6-pole with 2 auxiliary contacts (1 x NO, 1 x NC | ||
| Version | Cable entry | Order No. |
| 6-pole | 4xM40/1xM25 | GHG 263 0050 R0001 |
| 6-pole | 4xM25 | GHG 263 0050 R0006 |
| 6-pole EMERGENCY STOP | 4xM40/1xM25 | GHG 263 0050 R0002 |
Accessories
| Type | Application | Fixing method | Order No. |
| 3 | wall mounting | snap-on | GHG 610 1953 RO118 |
| 3 | pipe mounting | snap-on | GHG 610 1953 R0110 |
| 3 | trellis mounting | snap-on | GHG 610 1953 R0118 |
| Mounting plate for Ex-safety switch 40 A 6-pole | |||
| Type | Application | Fixing method | Order No. |
| 3 | 2 x pipe mounting | screw-on | GHG 610 1953 R0110 |
Dimension
Ex-safety switch 80 A
Technical Data
| EC-type examination certificate |
| GB-certification of conformity |
| Marking acc. to ATEX |
| Marking acc. to IECEx |
| Application temperature |
| Rated voltage |
| Rated current |
| Frequency |
| Rated making-/breaking capacity AC-3 |
| U 230V |
| U 400V |
| Ue 500V |
| Ue 690V |
| Back-up fuse |
| up to 400V AC up to 500V AC |
| up to 690V AC |
| Main contact |
| Auxiliary-/signal contact |
| Degree of protection |
| Insulation class |
| Cable glands/enclosure drilling |
| Weight |
| 3-pole |
| 6-pole |
| Enclosure material |
| Enclosure colour Auxiliary contact |
| Padlocking |
| BVS 15 ATEX E125X |
| CCC |
| @x> II 2 G Ex db e II/lIC T5/T6 Gb /@x> Il 2 D Ex tb C T80°C Db |
| Ex db e IlB/lIC T5/T6 Gb |
| Ex tb lI T80°C Db |
| IECEx BVS 15.0103X |
| -20°C +40°c" |
| Up to 690V |
| Up to 80A |
| 50/60Hz |
| 80A |
| 80A 80A |
| 63A |
| Up to 160A gL |
| Up to 160A gL |
| Up to 125A gL |
| 2x25mm2 |
| 2x4mm2 |
| IP66 acc. to EN 60529 |
| 1 |
| M25(d=8-17mm) |
| M32(d=12-21mm) |
| M40(d=21-35mm) |
| Option: metal flange with thread |
| Approx. 6.5kg |
| Approx. 9.0kg |
| Glass-fibre reinforced polyester |
| Black 1 NO making-lagging; breaking - leading |
| 1 x NC making - lagging; breaking - leading Can be locked in OFF position with 3 commercially available padlocks |
Ex-safety switch 80 A
Ordering information
| Version | Cable entry | Order No. |
| 3-pole | 2xM50/1xM25 | GHG 264 0020 R0001 |
| 3-pole EMERGENCY STOP | 2xM50/1xM25 | GHG 264 0020 R0002 |
| 3-pole | 2xM32 metal entries | GHG264 0020 R9105 |
| Version | Cable entry | Order No. |
| 6-pole | 4xM50/1xM25 | GHG 264 0021 R0001 |
| 6-pole EMERGENCY STOP | 4xM50/1xM25 | GHG 264 0021 R0002 |
Accessories
| Type | Application | Fixing method | Order No. |
| 3 | 2 x pipe mounting | screw-on | GHG 610 1953 R0110 |
Dimension
Ex-safety switch 125 A
Technical data
| BVS15 ATEX E125X |
| cCC |
| @X> Il 2 G Ex db eb ia lIC/lB/IB+H2 T6/T5 Gb/@X II 2 D Ex tb IIIC T80°C Db |
| Ex db eb ia IIC/IIB/IIB+H2 T6/T5 Gb |
| Ex tb IIIC T80°C Db |
| IECEx BVS 22.0019X |
| -20°C+40°c" |
| Up to 690V |
| 50/60Hz |
| 125A |
| 125A |
| 125A 110A |
| Up to 200A gL |
| Up to 200A gL |
| Up to 160A gL |
| 1x50/70mm2 |
| 6x95mm2/2x95mm2 |
| 2x4mm2 |
| IP66 acc. to EN 60529 |
| M25(d=8-17mm) |
| M40(d=16-28mm) |
| M63(d=27-48mm) |
| Option: metal flange with 2 x thread |
| Approx. 16kg |
| Approx.31kg |
| Glass-fibre reinforced polyester |
| Steel, powder-coated |
| Black White |
| 1 NO making-lagging: breaking-leading |
| 1 NC making-lgging breaking-leading |
| Can be locked in OFF position with 3 commercially available padlocks |
| GB-certification of conformity |
| Marking acc. to ATEX |
| Marking acc. to IECEx |
| Application temperature |
| Rated voltage Frequency |
| Rated making-/breaking capacity AC-3 |
| U 230V |
| U 400v |
| U. 500V |
| U 690V |
| Back-up fuse |
| up to 400V AC |
| up to 500V AC |
| up to 690V AC |
| Main contact |
| 3-pole |
| 6-pole |
| Auxiliary-/signal contact |
| Degree of protection |
| Insulation class |
| Cable glands/enclosure drilling |
| Weight 3-pole |
| 6-pole |
| Enclosure material |
| 3-pole |
| 6-pole |
| Enclosure colour |
| 3-pole |
| 6-pole |
| Auxiliary contact |
| Padlocking |
Ex-safety switch 125 A
Ordering information
| Version | Cable entry | Order No. |
| 3-pole | 2xM63/1xM25 | GHG 265 0010 R0001 |
| 3-pole | 2xM50 metal entries | GHG265 0010 R9193 |
| 4-pole | 2xM40 | GHG 265 0010 R0005 |
| 3-pole EMERGENCY STOP | 2xM63/1xM25 | GHG 265 0010 R0002 |
| 6-pole | 4xM63/1xM25 | EXKO 224716 K 0000 |
| 6-pole EMERGENCY STOP | 4xM63/1xM25 | EXKO 224726 K 0000 |
Accessories
| Type | Application | Fixing method | Order No. |
| 3 | 2 x pipe mounting | screw-on | GHG 610 1953 R0110 |
Dimension
Ex-safety switch 180A
Technical data
| GB-certification of conformity |
| Marking acc. to ATEX |
| Marking acc. to IECEx |
| Application temperature |
| Rated voltage Frequency |
| Rated making-/breaking capacity AC-3 |
| U 230V |
| U 400V |
| U 500V |
| Ue 690V |
| Back-up fuse |
| up to 400V AC |
| up to 500V AC |
| up to 690V AC |
| Main contact |
| 3-pole |
| 6-pole |
| Auxiliary-/signal contact |
| Degree of protection |
| Insulation class Cable glands/enclosure drilling |
| Weight 3-pole |
| 6-pole |
| Enclosure material |
| 3-pole |
| 6-pole |
| Enclosure colour |
| 3-pole |
| 6-pole |
| Auxiliary contact |
| Padlocking |
| BVS 15 ATEX E125X | |
| CCC | |
| @x> II 2 G Ex db eb ia IIC/lIB/lIB+H2 T6/T5 Gb/x>II 2 D Ex tb IIIC T80*C | |
| Ex db eb i IC/lB/lB8+H2 T6/T5 Gb | |
| Ex tb ICT80°C Db | |
| IECEx BVS 22.0019X | |
| -20°C+40°c | |
| Up to 690V 50/60Hz | |
| 180A | |
| 180A | |
| 180A 125A | |
| Up to 250A gL | |
| Up to 250A gL Up to 200A gL | |
| 1x120mm2 6x150mm2/2x95mm2 | |
| 2x4mm2 | |
| IP66 acc. to EN 60529 | |
| M25(d=8-17mm) M40(d=16-28mm) | |
| M63(d=27-48mm) Option: metal flange with 2 x thread | |
| Approx.16.5kg | |
| Approx.31.5kg | |
| Glass-fibre reinforced polyester | |
| Steel, powder-coated | |
| Black | |
| White | |
| 1 x NO making -lagging: breaking- leading | |
| 1 x NC making-lagging: breaking-leading | |
Ex-safety switch 180A
Ordering information
| Version | Cable entry | Order No. |
| 3-pole | 2xM63/1xM25 | GHG 266 0006 R0001 |
| 3-pole EMERGENCY STOP | 2xM63/1xM25 | GHG 266 0006 R0002 |
| 6-pole | 4xM63/1xM25 | EXKO 224716 L 0000 |
| 6-pole EMERGENCY STOP | 4xM63/1xM25 | EXKO 224726 L 0000 |
Accessories
| Type | Application | Fixing method | Order No. |
| 3 | 2 x pipe mounting | screw-on | GHG 610 1953 R0110 |
Dimension
CEAG GHG25 safety switches and switch disconnectors
Applications
.Provides motor control and disconnect protection for Zone 1, 2, 21 and 22 hazardous areas
: Isolates the power supply on electrical installations and apparatus during maintenance, cleaning and repair work
: Can be protected against inadvertent switching on by our integrated locking design with up to three padlocks in the OFF position
.: High isolating and switching capacities for safer operations
.- Designed for high-reliability in industrial areas: chemical plants, paint manufacturing plants and oil and gas refineries
Standards
: IEC 60079-0/ EN IEC 60079-0 general requirements : IEC 60079-1 / EN IEC 60079-1 flameproof requirements "d" : IEC 60079-7 / EN IEC 60079-7 increased safety requirements "e" : IEC 60079-31 / EN 60079 protection by enclosure "t"
Certifi cates and markings
:BVS 20 ATEX E 094 X; IECEx BVS 20.0076 X
:ATEX marking: lI 2G Ex db eb IIC/lIB T6/T5/T4 Gb lI 2D Ex tb IlIC { \mathsf { T } } 8 0 ^ { \circ } { \mathsf { C } } Db
:lECEx marking: Ex db eb IIC/lIB T6/T5/T4 Gb Ex tb IIIC { \mathsf { T } } 8 0 ^ { \circ } { \mathsf { C } } Db
Standard materials and fi nishes
Enclosure - GRP black (Glass-Fibre Reinforced Polyester) or Stainless Steel (AISI 316L)
. Gasket - Silicone, foamed
.Lid screws - M4 / M6 captive screws (304 stainless steel)
: Mounting plates and protective canopies - Glass-Fibre Reinforced Polyester
Technical specifi cations
. Ambient temperature range: - 5 5 ^ { \circ } C up to + 5 5 ^ { \circ } C
:30,000 switching cycles electrical and mechanical lifetime
. Connecting terminals: Main contact: 1 x 2 . 5 - 1 6 \mathsf {mm } ^ { 2 } , 2 x 1 . 5 - 1 0 \mathsf {mm } ^ { 2 } Auxiliary contact 1NO: 1 x 0 . 5 - 2 . 5 \mathsf {mm } ^ { 2 } (pin cable lug), 1 x 2 . 5 - 1 6 \ : {mm } ^ { 2 } Auxiliary contact: 1 x 0 . 5 - 2 . 5 \mathsf {mm } ^ { 2 } - 2 x 0 . 5 - 1 . 5 \mathsf {mm } ^ { 2 }
.Environmental degree of protection: IP66
.High impact resistance: IK 09
.Enclosure mounting - 4 holes for M4 to M6 screws
:Retrofittable auxiliary contacts
Electrical ratings
.Rated operating voltage (Ue): 690V - 50/60Hz; 60/120V DC :Rated operating current (le): max 32A Back-up fuse 50A gG short circuit current limitation :Isolating functions (IEC/EN 60947-3), AC-3, DC-23 switching capacity
Dimensions and weights:
| Enclosure type | A(mm) | B (mm) | C (mm) | X (mm) | Y (mm) | Weight (kg) |
| GRP Size 1 | 110 | 170 | 129 | 96 | 150 | 1.54 |
| GRP Size 2 | 140 | 225 | 156 | 123 - 126 | 197 | 2.00 |
| GRP Size 3 | 271 | 271 | 200 | 247 | 247 | 3.15 |
| Stainless Steel Size 2 | 175 | 392.5 | 216 | 109.5 | 362.5 | 4.55 |
| StainlessSteel Size 3 | 312.5 | 392.5 | 216 | 247 | 362.5 | 6.44 |
CEAG GHG25 safety switches and switch disconnectors
Ordering details - Switch Disconnector:
| Load | Auxilary contact 1No2 | GRP | GRP + internal earth plate + stud | Stainless Steel+ ext. earth stud | Cable entries | Order No. | |||
| Enclosure type | Cross section | 20A | 25 A 32 A | ||||||
| Switch-disconnector 3-pole | |||||||||
| Size 1 | 2.5 mm2 | x | x | x | |||||
| Size 1 | 4.0 mm2 | x | x x | x | x | 2x M32,1x M25 2x M32,1x M25 | GHG2521311R0303 | ||
| Size 2 | 6.0 mm2 | x | x x | x | x | ||||
| Size 3 | 10.0 mm2 | x | x x | x | x | 2x M40,1x M25 | GHG2521312R0303 GHG2521313R0309 | ||
| Size 3 | 16.0 mm2 | x | x x | x | x | ||||
| Size 1 | 2.5 mm2 | x | x | x | 2x M25,1x M20 | GHG2521311R0322 | |||
| Size 1 | 4.0 mm2 | x | x x | x | x | ||||
| Size 2 | 6.0 mm2 | x | x x | x | x | 2x M25,1x M20 | GHG2521312R0322 | ||
| Size 3 | 10.0 mm2 | x | x x | x | x | ||||
| x | X x | X | x | 2x M32,1x M20 | GHG2521313R0328 | ||||
| Size 3 Size 2 | 16.0 mm2 2.5 mm2 | x | X | X | x | ||||
| x | x x | X | x | 2x M25,1x M20 | GHG2521322R0341 | ||||
| Size 2 Size 2 | 4.0 mm2 6.0 mm2 | x | x | x | x | ||||
| Size 3 | 10.0 mm2 | x | x x x | x | x | ||||
| Size 3 | 16.0 mm2 | x | x | x | 2x M32,1x M20 | GHG2521323R0345 | |||
| Switch-disconnector 4-pole | x x | ||||||||
| Size 1 | 2.5 mm2 | x | x | 2x M32,1x M25 | GHG2521411R0003 | ||||
| Size 1 | 4.0 mm2 | x | x | x | |||||
| Size 2 | 6.0 m2 | x | x X | x | 2x M32, 1x M25 | GHG2521412R0003 | |||
| Size 3 | 10.0 mm2 | x | x x | ||||||
| Size 3 | 16.0 mm2 | x | x x | x x | 2x M40, 1x M25 | GHG2521413R0009 | |||
| Size 1 | 2.5 mm2 | x | x | x | |||||
| Size 1 | 4.0 mm2 | x | x x | x | 2x M25,1x M20 2x M25,1x M20 | GHG2521411R0022 | |||
| Size 2 | 6.0 mm2 | x | X | x | |||||
| Size 3 | 10.0 mm2 | x | x x x | x | 2x M32,1x M20 | GHG2521412R0022 GHG2521413R0028 | |||
| Size 3 | 16.0 mm2 | x | X | x | |||||
| Size 2 | 2.5 mm2 | x | x x | x | 2x M25,1x M20 | ||||
| Size 2 | 4.0 mm2 | x | X | x | |||||
| Size 2 | 6.0 mm2 | x | X x | x | GHG2521422R0041 | ||||
| Size 3 | 10.0 mm2 | x | x | ||||||
| x | x x | x | 2x M32,1x M20 | GHG2521423R0045 | |||||
| Size 3 | 16.0 mm2 | x | x | x | |||||
CEAG GHG25 safety switches and switch disconnectors
Ordering details - Switch Disconnector:
| Load | Auilary contact 1No2 | GRP + internal earth plate + | Stainless Steel+ | ||||||
| Enclosure type | Cross section | 20A | 25A 32A | GRP | stud | ext. earth stud | Cable entries | Order No. | |
| Switch-disconnector 6-pole | |||||||||
| Size 3 | 2.5 mm2 | x | x | ||||||
| Size 3 | 4.0 m2 | x | x | x | |||||
| Size 3 | 6.0 mm2 | x | |||||||
| Size 3 | 10.0 mm2 | x | x x | ||||||
| Size 3 | 16.0 mm2 | x | x | ||||||
| Size 3 | 2.5 mm2 | x | x | ||||||
| Size 3 | 4.0 mm2 | x | x | x | |||||
| Size 3 | 6.0 mm2 | x | x | x | |||||
| Size 3 | 10.0 mm2 | x | x | x | |||||
| Size 3 | 16.0 mm2 | x | x | x | |||||
| Size 3 | 2.5 mm2 | x | x | 4x M25,1x M20 | GHG2521623R0041 | ||||
| Size 3 Size 3 | 4.0 mm2 6.0 mm2 | x x | x x | x | |||||
| Size 3 | x | ||||||||
| Size 3 | 10.0 mm2 | x | x x | x | |||||
| 16.0 mm2 | x | x | |||||||
| Size 3 Size 3 | 2.5 mm2 | x x | x x | x x | 4x M32, 1x M25 | GHG2521613R0302 | |||
| Size 3 | 4.0 mm2 6.0 mm2 | x | |||||||
| Size 3 | 10.0 mm2 | x x | x x | X x | |||||
| Size 3 | 16.0 mm2 | x x | x | x | x | ||||
| Size 3 | 2.5 mm2 | x | x | x | GHG2521613R0322 | ||||
| Size 3 | 4.0 mm2 | x | x | x | |||||
| Size 3 | 6.0 mm2 | x | x | x | |||||
| Size 3 | 10.0 mm2 | x | x | x | |||||
| Size 3 | 16.0 mm2 | x | x | x x | x | ||||
| Size 3 | 2.5 mm2 | x | x | x | 4x M25,1x M20 | GHG2521623R0341 | |||
| Size 3 | 4.0 mm2 | x | X | ||||||
| Size 3 | 6.0 mm2 | x | x | X | x | ||||
| Size 3 | 10.0 mm2 | x | x | x | x | ||||
| Size 3 | 16.0 mm2 | x | x | x | x | x | |||
EAG GHG25 safety switches and switch disconnectors
Ordering details - Safety Switches:
| Load | Auxiliary contact 1No2 | GRP | GRP + internal earth plate + stud | Stainless Steel+ ext. earth stud | Cable entries | Order No. | |||
| Enclosure type | Cross section | 20A | 25 A 32A | ||||||
| Safety switch 3-pole | |||||||||
| Size 1 | 2.5 mm2 | x | x | x | |||||
| Size 1 | 4.0 mm2 | x | x x | x | x | 2x M32,1x M25 2x M32,1x M25 | GHG2522311R0303 | ||
| Size 2 | 6.0 mm2 | x | x x | x | x | ||||
| Size 3 | 10.0 mm2 | x | x x | x | x | 2x M40,1x M25 | GHG2522312R0303 GHG2522313R0309 | ||
| Size 3 | 16.0 mm2 | x | x x | x | x | ||||
| Size 1 | 2.5 mm2 | x | x | x | 2x M25,1x M20 | GHG2522311R0322 | |||
| Size 1 | 4.0 mm2 | x | x x | x | x | ||||
| Size 2 | 6.0 mm2 | x | x x | x | x | 2x M25,1x M20 | GHG2522312R0322 | ||
| Size 3 | 10.0 mm2 | x | x x | x | x | ||||
| Size 3 | 16.0 mm2 | x | x x | x | x | 2x M32,1x M20 | GHG2522313R0328 | ||
| Size 2 | 2.5 mm2 | x | x | x | x | ||||
| Size 2 | 4.0 mm2 | x | x x | x | x | 2x M25,1x M20 | GHG2522322R0341 | ||
| Size 2 | 6.0 mm2 | x | x x | x | x | ||||
| Size 3 | 10.0 mm2 | x | x X | x | x | ||||
| Size 3 | 16.0 mm2 | X | x | x | x | 2x M32,1x M20 | GHG2522323R0345 | ||
| EMERGENCY STOP 3-pole | x | ||||||||
| Size 1 | 2.5 mm2 | x | x | x | 2x M32,1x M25 | GHG2524311R0303 | |||
| Size 1 | 4.0 mm2 | x | x | x | x | x | |||
| Size 2 | 6.0 mm2 | x | x | x | x | x | 2x M32,1x M25 | GHG2524312R0303 | |
| Size 3 | 10.0 mm2 | x | x x | x | x | ||||
| Size 3 | 16.0 mm2 | x | x | x | x | x | 2x M40,1x M25 | GHG2524313R0309 | |
| Size 1 | 2.5 mm2 | x | x | x | |||||
| Size 1 | 4.0 mm2 | x | x | x | x | x | 2x M25,1x M20 2x M25,1x M20 | GHG2524311R0322 | |
| Size 2 | 6.0 mm2 | x | x x | x | x | ||||
| Size 3 | 10.0 mm2 | x | x | x | x | x | 2x M32,1x M20 | GHG2524312R0322 GHG2524313R0328 | |
| Size 3 | 16.0 mm2 | X | x x | x | x | ||||
| Size 2 | 2.5 mm2 | x | x | x | x | 2x M25,1x M20 | |||
| Size 2 | 4.0 mm2 | x | x x | x | x | ||||
| Size 2 | 6.0 mm2 | x | x | x | x | x | GHG2524322R0341 | ||
| Size 3 | 10.0 mm2 | x | x | x | |||||
| x x | x x | x | 2x M32,1x M20 | GHG2524323R0345 | |||||
| Size 3 | 16.0 mm2 | x | x | ||||||
EAG GHG25 safety switches and switch disconnectors
Ordering details - Safety Switches:
| Load | Auiliary contact 1No2 | GRP | GRP + internal earth plate + stud | Stainless Steel+ ext. earth stud Cable entries | |||||
| Enclosure type | Cross section | 20A 25 A | 32A | ||||||
| EMERGENCY STOP 6-pole | |||||||||
| Size 3 | 2.5 mm2 | x | x | x | x | ||||
| Size 3 | 4.0 mm2 | x | x x | x | x | ||||
| Size 3 | 6.0 mm2 | x | x X | x | x | ||||
| Size 3 | 10.0 mm2 | X | x X | X | X X | ||||
| Size 3 | 16.0 mm2 | X | X X x | X | GHG2522613R0322 | ||||
| Size 3 | 2.5 mm2 | x | x | x | |||||
| Size 3 | 4.0 m2 | x | x x | x | x | ||||
| Size 3 | 6.0 m2 | x | x x | x | x | 4x M25,1x M20 | |||
| Size 3 | 10.0 m2 | X | x X | X | x x | ||||
| Size 3 | 16.0 mm2 | X | X x x | X x | 4x M25,1x M20 | GHG2522623R0341 | |||
| Size 3 | 2.5 mm2 4.0 mm2 | X x | x | x | X | ||||
| Size 3 | X | x X | X | x | |||||
| Size 3 | 6.0 m2 | x x | X | X | |||||
| Size 3 Size 3 | 10.0 mm2 16.0 mm2 | x x | x x x | x | X x | ||||
Ordering details: Accessories:
| Type Description | Order No. | |
| Auxiliary switches, coupling set and pin cable lugs | ||
| Ex - d Aux switch | 1NC | GHG2593251R0001 |
| Ex - d Aux switch | 1NO | GHG2593241R0001 |
| Ex - d Aux switch | 1 NO +1 NC | GHG2593211R0001 |
| Ex-i Upgrading kit | GHG2501903R0001 | |
| Coupling set for 2x switch blocks | GHG2501901R0001 | |
| Set of pin cable lugs for Aux | (2x 0.5 - 1mm2, 2x 1.5 - 2.5mm2) | GHG2501904R0001 |
| Set of pin cable lugs for Aux | (10x 0.5 - 1mm2, 10x 1.5 -2.5mm2) | GHG2501904R0002 |
Circuit diagrams
3pol. Main Switch c/w aux NO / optional aux/ 3pol. Main Switch c/w aux NO / optional aux
EAG GHG25 safety switches and switch disconnectors
Ordering details: Accessories:
| Type | Fixing method | Order No. |
| Mounting plate for Size 1 safety switches and switch disconnectors | ||
| Wall mounting | snap on | GHG6101953R0104 |
| Pipe clamp | snap on | GHG6101953R0105 |
| Trellis-work mounting | snap on | GHG6101953R0106 |
| Mounting plate for Size 2 safety switches and switch disconnectors | ||
| Wall mounting | snap on | GHG6101953R0118 |
| Pipe clamp | snap on | GHG6101953R0110 |
| Trellis-work mounting | snap on | GHG6101953R0118 |
| Mounting plate for Size 3 safety switches and switch disconnectors | ||
| Pipe clamp (2X) | screw-on | GHG6101953R0110 |
| Type | OU | Order No. |
| Mounting plate accessories | ||
| Label holder with type label (blank) for mounting plate size 2 and 3 | 10 | GHG6101953R0057 |
| Mounting hardware for pipes 1" ( 27 - 30 mm) for pipe clamp mounting plates | 10 | GHG6101953R0020 |
| Type Application notes | Order No. | |
| Protective canopy - requires mounting plate for installation | ||
| Canopy for size 1 safety switches and switch disconnectors | GHG6101955R0102 | |
| Canopy for size 2 safety switches and switch disconnectors | installs on pipe clamp mounting plates only | GHG6101955R0104 |
| Canopy for size 3 safety switches and swith disconnectors | GHG6101955R0106 | |
Dimensions: Mounting plates and canopies
For size 1 safety switches and switch disconnectors
Protective canopy for wall, trellis and pipe clamp mounting plates
EAG GHG25 safety switches and switch disconnectors
Dimensions: Mounting plates and canopies
For size 2 safety switches and switch disconnectors
Ex-control switches GHG292 and GHG293
Product introduction
The explosion-protected control switches are for use in the Zones 1, 2, 21 and 22. The series features are easy-toinstall and easy-to-connect design. This control switch can be implemented with up to 6 contacts and for 2 to 5 switch positions. Thus, almost all applications in modern control engineering can be covered.
Product features
.Original packaging from Germany is in high quality.
. The impact-resistant, glass-fibre-reinforced polyester enclosure material is a prerequisite for withstanding even the most rugged industrial operating conditions.
: A labyrinth seal in the cover guarantees the degree of protection IP66. It is suitable for all indoor or outdoor environment with safety and reliability.
. Easily accessible connection terminals.
. Have a terminal cross section up to 6 { \mathsf {mm } } ^ { 2 }
. Integrated locking facility.
. Significant cost saving with the CEAG mounting system.
Ex-control switches (GHG292/GHG293)
Ex-control switch type 292 without and type 293 with measuring instrument
Technical data
| With GHG29 Switch | With GHG28 Switch | |
| EC-type examination certificate | PTB 99 ATEX 1163 | PTB 99 ATEX 1163 |
| GB-certification of conformity | CCC | CCC |
| IECEx-certification of conformity | IECEx BKI 07.0011 | IECEx BKI 07.0011 |
| Marking acc. to ATEX | @XI12 G Ex de ia IC T5/T67 | @X II 2 G Ex de ia lIC T5 /T6/ |
| Marking acc. to IECEx | @X II 2 D IP66 T 80*C | > II D IP66T 80*C |
| Ex de ia IIC T5 or T6 | Ex de i IC T5 or T6 | |
| Application temperature | Ex tD A21 IP66 T49*C | Ex tD A21 IP66 T49*C |
| -20°C40°C | -20°C40°C | |
| Rated voltage | -55*C+47*C (T6).+5*C (T5) (option) | -55*C +47*C (T6).+5*C (T5) (option) |
| up to 500 V | up to 690V | |
| Rated current | 16A 0.4A | 20A 0.4A |
| Rated current gold contacts Overload range (Type GHG293 only) | ||
| 10 fold - 25 sec. | 10 fold - 25 sec. | |
| 25 fold - 4 sec. | 25 fold - 4 sec. | |
| 50 fold - 1 sec. | 50 fold - 1 sec. | |
| Indicated 1:1.5 | Indicated 1:1.5 | |
| Measuring range (Type GHG293 only) | Max. 0-25 A direct/n/1A | Max. 0-25 A direct/n/1A |
| Accuracy (Type GHG293 only) | Class 2.5 | Class2.5 |
| Circuit (Type GHG293 only) | Moving iron | Moving iron |
| Rated marking -/ | 230V/6A | 230V/8A |
| Rated breaking capacity AC15 | 400V/4A | 400V/6A |
| Rated marking -/ | 24V/2A | 24V/6A |
| Rated breaking capacity DC3 | 230V/0.3A | 230V/0.4A |
| Connecting terminals | 2x0.5-2.5mm2 or 1x1.0-6.0mm2 | 2x0.5-2.5mm2 or 1x1.0-6.0mm2 |
| Degree of protection Cable gland/gland plates/ | IP66 1xM25 (08-17mm)2) | IP66 1xM25 (08-17mm)1) |
| Enclosure drilling | ||
| Dimension (L x W x H) | 170x110x129mm | 225x110x129mm |
| Weight | Approx. 1.1kg (1 level) Approx. 1.25kg (2 level) | Approx. 1.9kg (1 level) Approx. 2.05kg (2 level) |
| Approx. 1.40kg (3 level) | ||
| Enclosure materia | Approx. 2.20kg (3 level) | |
| Enclosure colour | Polyamide | Polyamide |
| Black | Black |
Ex-control switches (GHG292/GHG293)
Ordering logic
| A | B1 | B2 | c | D | E | E2 F | |
| GHG 29 | - | ||||||
| - | - | - | |||||
| Code | Component | Code | |||||
| Control switch | GHG 292 GHG 293 | ||||||
| Control switch with measuring instrument | |||||||
| Code | Switch mechanism | Code | |
| B1 | spring - engaging - spring | 4 | |
| engaging - engaging - engaging | 5 | ||
| engaging - engaging | 6 | ||
| spring - engaging - engaging | 7 | ||
| engaging - engaging - spring | . | 8 | |
| Code | Silver contact points | Silver contact points | ||||
| B2 | F X | Code 060 | 3_5 | 15 | 034 | |
| I3 | 062 | l4 F- 1P | ||||
| iv | 2 | 065 | 45° 90° 135 1315 | 037 049 | ||
| 2 1214 | 061 | 12 4 III X | 023 | |||
| t--- | 2 | 063 | 019 | |||
| 067 | 033 | |||||
| + | 45° 135° 12 | 011 | E | 5/7 45° 90° 135° 12141618 1/3 | 024 | |
| Code | Label | Content | Code | Content | Code | ||||
| 0 | 1 | 001 | 0 | 1 | 018 | ||||
| 1 | 002 | AUS | AUTO | EIN | 019 | ||||
| STOP | START | 003 | AUS | HAND | AUTO | 020 | |||
| HAND | AUTO | 004 | ORTLICH | AUS | FERN | 021 | |||
| SENKEN | HEBEN | 005 | START | NORMAL | STOP | 022 | |||
| REMOTE | LOCAL | 006 | OFF | 0 | ON | 023 | |||
| 1 | 0 | 007 | HAND | OFF | AUTO | 024 | |||
| AUS | BETRIEB | EIN | 008 | 0 | IN | START | 025 | ||
| AUS | 0 | EIN | 009 | MAN | AUTO | 026 | |||
| AUF | 0 | AB | 010 | START | STOP | 027 | |||
| Entriegelt | 0 | Verriegit | 011 | HEBEN | SENKEN | 028 | |||
| OUT | OF | HAND | 012 | OFF | ON | 029 | |||
| LOCAL | REMOTE | AUTO | 013 | AUS | EIN | 030 | |||
| STOP | 0 | START | 014 | HAND | AUTO | 031 | |||
| HAND | 0 | AUTO | 015 | ON | OFF | 032 | |||
| AUF | AUS | ZU | 016 | 1 | II | III | 033 | ||
| HAND | AUS | AUTO | 017 |
Ex-control switches (GHG292/GHG293)
| Code | Locking facility | Code | |
| D | None | 0 | |
| Centre | 1 | ||
| Left | 2 | ||
| Right | 3 | ||
| Code | Movement | Code |
| Direct connection | 01 | |
| Ct connection 1 / A | 02 | |
| Connecting 0 - 20/24 mA (scale 0 - 100% / 120%) | 05 | |
| Connecting 4 - 20/24 mA (scale 0 - 100% / 120%) | 06 | |
| Moving-coil connection 0 - 20/24 mA (scale 0 - 100% / 120%) | 07 | |
| Moving-coil connection 4 - 20/24 mA (scale 0 - 100% / 120%) | 08 |
| Code | Measuring range/scale | Code | Measuring range/scale | Code |
| E2 | 0-1 | 002 | 0-75/112.5A | 013 |
| 0-2.5/3.75A2) | 003 | 0-100/150A | 014 | |
| 0-5/7.5A2) | 004 | 0-150/225A | 015 | |
| 0-10/15A2) | 005 | 0-200/300A | 016 | |
| 0-15/22.5A | 006 | 0-250/375A | 017 | |
| 0-20/30A2) | 008 | 0-300/450A | 018 | |
| 0-30/45A | 009 | 0-400/600A | 019 | |
| 0-40/60A | 010 | 0-500/750A | 020 | |
| 0-50/75A | 011 | 0-600/900A | 021 | |
| 0-60/90A | 012 | 0-100%/150% | 031 |
| Code | Cable entry | Inscription | Code |
| F1 | Enty type | Entry direct in enclosure | GEH |
| Entry via plastic flange | FLK | ||
| Entry via metal flange | FLM | ||
| F2 | Entry element | Only threaded entry | BO |
| Cable entry moulded plastic | GK | ||
| Cable entry metal | GM* | ||
| Cable entry with plug | GV | ||
| F3 | Size | M12, M16, M20, M25, M32, M40 | M... |
| 021, 026 | 0... | ||
| F4 | Number | No. of entries | * |
Example for ordering code
GHG 293 with silver contact points, switch mechanism "5", contact arrangement "063"
Label " HAND-0-AUTO", CAN BE LOCKED AT " 0 "
Measuring instrument AM72 for Ct connection "n/1A", scale " 0-50/75A"
Cable entry \boldsymbol { \mathsf { 1 } } x \boldsymbol { \mathsf { \Omega } } threaded entry M25 on bottom direct entry
| Code A | B1 | B2 | D | E1 | E2 | F1 | F2 | F3 | F4 | ||
| GHG293/ | 5/ | 063/ | 015/ | 1/ | 2/ | 011/ | GEH/ | B0/ | M25/ | 1 |
Ex-control switches (GHG292/GHG293)
Accessories
| Type | Application | Mounting technique | OU | Order No. |
| 2 | wall mounting | snap-on | 1 | GHG 610 1953 RO104 |
| 2 | pipe mounting | snap-on | 1 | GHG 610 1953 RO105 |
| 2 | trells-work mounting | snap-on | 1 | GHG 610 1953 R0106 |
| wall mounting | snap-on | 1 | GHG 610 1953 R0128 | |
| 4 | trellis-work mounting | snap-on | 1 | GHG 610 1953 RO128 |
| 4 | pipe mounting | snap-on | 1 | GHG 610 1953 R0132 |
| Type | Application | Mounting technique | OU | Order No. |
| 3 | wall mounting | snap-on | 1 | GHG 610 1953 R0118 |
| 3 | pipe mounting | snap-on | 1 | GHG 610 1953 R0110 |
| 3 | trelis-work mounting | snap-on | 1 | GHG 610 1953 R0118 |
| wall mounting | snap-on | 1 | GHG 610 1953 R0128 | |
| trellis-work mounting | snap-on | 1 | GHG 610 1953 R0128 | |
| pipe mounting | snap-on | 1 | GHG 610 1953 R0132 | |
| Snap-on mounting accessories | 10 | GHG 610 1953 R0041 | ||
Dimension
ESA control switch
Product introduction
ESA isolating control switch is for use in the Gas-Ex-Areas of Zone 1/Zone 2 classification, which can be used as motor isolators and for MCB to 63A.
Technical data
| Certificate of conformity | ANZEx04.3023 |
| Type of protection | Exd |
| Degree of protection | IP66/67 |
| Gas group | IIB |
| Standard materials | Enclosure - cast aluminium |
| Operating handle, shaft & bush - stainless steel Cover screws - stainless steel |
| Catalogue No. | ACl current rating | No. of poles | AC3 max KW rating |
| Isolating switches | |||
| ESA 203-C26 | 32 Amps | 4 | 11 KW |
| ESA 203-C32 | 40 Amps | 4 | 15 KW |
| ESA 203-C42 | 63 Amps | 4 | 18.5 KW |
| ESA K400 KG32 | 32Amps | 4 | 11KW |
| ESA K400 KG41 | 40 Amps | 4 | 15KW |
| ESA K400 KG64 | 63 Amps | 4 | 18.5KW |
| Change over switches (with centre off) | |||
| ESA 212-C26 | 32 Amps | 3 | 11KW |
| ESA 211-C32 | 40 Amps | 2 | 15 KW |
| ESA 211-C42 | 63 Amps | 2 | 18.5 KW |
| Change over switches (without centre off) | |||
| ESA 22-C26 | 32.Amps | 3 | 11KW |
| ESA.221-C32 | 40.Amps. | 2 | 15 Kw |
| ESA 221-C42 | 63 Amps | 2 | 18.5 KW |
| Reversing switches | |||
| ESA 401E-C26 | 32.Amps | 3 | 11 KW |
| ESA 622E- C26 | 32 Amps | 1 | 11 KW |
EMD control station
Product introduction
EMD explosion-protected control station is for use in the Gas-Ex-Areas of Zone 1/Zone 2 classification, which can be used where earthing is required to: - Provide earth connection to prevent static build up
- Monitor earth continuity
- Activate alarms & shut down process when earth connection is interrupted.
Technical data
| Certificate of conformity | ANZ Ex07.3049X |
| Type of protection | Exd ib |
| Degree of protection | IP66 |
| Gas group | II(H2) |
| Standard materials | Body& cover - copper free Aluminium Gasket - neoprene |
| Cover screws -stainless steel Grey polyurethane finish |
Ordering information
| Description | Part No. | Weight |
| Single unit c/w earth clamp | EIBA783-EMD1 | 14kg |
| Double unit c/w earth clamp | EIBA786-EMD2 | 19kg |
| Single unit c/w earth clamp & by-pass switch | EIBA786-EMD1-BP | 20kg |
EMA motor starter
Product introduction
EMA direct-on-line motor starter is for use in the Gas-Ex-Areas of Zone 1/ Zone 2 classification, which can be used for DOL starting of polyphase and single phase AC induction motors.
Technical data
| Certificate of conformity | ANZEx04.3000 |
| Type of protection | Exd |
| Degree of protection | IP67 |
| Gas group | IIB |
| Standard materials | Enclosure - copper free Aluminium Push button shafts & cover screws & bushes - |
| Stainless steel Push buttons& guards - type 6/6 nylon |
| Catalogue No. | Rating | Current overload range |
| EMA11SS.25KW | (kw) 0.25 | (A) 0.63 - 1.0 |
| EMA11SS.55KW | 0.55 | 1.0-1.7 |
| EMA11SS1.5KW | 1.1/1.5 | 2.5-40 |
| EMA11SS2.2KW | 2.2 | 4.0-6.8 |
| EMA11S5.5KW | 4.1/5.5 | 9.0-13.0 |
| EMA11SS7.5KW | 7.5 | 12.0- 18.0 |
| EMA11SS11KW | 11 | 16.0 - 23.0 |
| EMA11SS15KW | 15 | 23.0 -32.0 |
| EMAB11SS22KW | 22 | 40.0-52.0 |
| EMAB11SS37KW | 37 | 58 - 72 |
Dimension
Ex-control station
Product introduction
The explosion-protected control stations are for use in the Zones 1, 2, 21 and 22. To provide remote means of motor control closing or disconnecting control circuit via send out orders or control program.
Product features
.: The enclosures consist of low-temperature impact-resistant thermoplastic which provides a high resistance to chemicals.
. Wide components which can meet all requirement.
: Original package from germany with Independent certificated Exed components.
. Easily able to mount control and signal components with accuracy position.
. The well through-out design with low side walls allows optimum cable connection.
The ordering logic for GHG411, GHG 413, GHG 414, GHG432, GHG434control stations (customize):
The order code is consisted of enclosure, components, label / accessory and cable entry/flange.
Part I: Enclosure
Part III: Label and accessory
Part IV: Cable entry and flange
Ex-control station
Part l: enclosure GHG 411/432/434
GHG41181, GHG41182, GHG41183, GHG432, GHG434
Technical data
| EC-type examination certificate | BVS 22 ATEX E 032X |
| GB-certification of conformity | ccc |
| IECEx-certification of conformity | IECEx BVS 22.0029 |
| Marking acc. to ATEX | @x Il 2 G Ex eb IIC/lB/lB+H2 T6/T5 Gb |
| Marking acc. to IECEx | @x> I 2 D Ex tb lICT80*C Db Ex eb IIC/lIB/lIB+H2 T6/T5 Gb; Ex tb IIIC T80*C Db |
| Application temperature | -20°C+40°C |
| Rated voltage | -55*C-+55*C(option) |
| Rated current | 690V |
| Connecting terminals | 16A |
| Degree of protection | 2x4mm2 |
| Insulation class | IP66 acc. to EN 60529 |
| Enclosure material | 1 |
| Enclosure colour | Polyamide Black |
Dimension
Enclosure GHG 413/414
Technical data
| Ex-control stations type 413. and 414. for individual configuration | ||
| EC-type examination certificate | PTB 00 ATEX 31171 | |
| IECEx certificate of conformity | IECEx BKI 04.00031 | |
| GB-certification of conformity | CCC | |
| Marking accd. to 2014/34/EU | @II 2 G Ex ed ib m IIC T6 1 | |
| @II 2 D Ex tD A21 IP66 T80 °C | ||
| Marking accd. to IECEx Permissible ambient temperature | Ex e II T6, Ex e ib IIC T6, Ex ed IIC T6 or Ex ed ib IIC T6,1) 20 °C up to +40 °C 1 | |
| 55 °C up to +55 °C (option) | ||
| Rated voltage | 690 V AC | |
| Rated current | 16 A | |
| Connecting terminals | see technical data for built-in components | |
| PE-connecting terminals | 2 x 4 mm3 | |
| Protection class | ||
| 1 Degree of protection accd. to EN 60529 | IP66 (standard) | |
| Type 413 84 | ||
| Cable glands/Gland plates/Enclosure drilling | Type 413 85 | |
| max. 2 x M25; 2 x M20 | max. 2 x M25; 2 x M20 | |
| Dimensions (L x W x H) | 122 x 120 x 81 mm | 220 x 120 x 81 mm |
| Weight (empty) Enclosure material | 0.85 kg | 1.45 kg |
| Enclosure colour | cast aluminium-silicon (AISi) | cast aluminium-silicon (AISi) |
| grey RAL 7031 | grey RAL 7031 | |
| Components arrangement | 2 mounting areas | 4 mounting areas |
| Cable glands/Gland plates/Enclosure drilling | Type 414 81 max. 3 x 21 for cable gland M20 | Type 414 82 max. 4 x 21 for cable gland M20 |
| max. 2 x 25.5 for cable gland M25 | ||
| Dimensions (L x W x H) | 166 x 140 x 76 mm | max. 2 x 25.5 for cable gland M25 286 x 140 x 76 mm |
| Weight (empty) | 1.40 kg | 2.10 kg |
| Enclosure material | stainless steel AISI 316 L | stainless steel AISI 316 L |
| Enclosure colour | polished | polished |
| Components arrangement | 2 mounting areas | 4 mounting areas |
Enclosure GHG 413/414
Mounting areas I Dimension drawing
\mathsf { X } = fixing dimension Dimensions in mm
Enclosure GHG 44\* 23
GHG44423, GHG44823, GHG44923, GHG44723 series
Technical data
| EC-type examination certificate | BVS22ATEX-E-006/PTB 99 ATEX 1044 |
| GB-certification of conformity | CCC |
| IECEx-certification of conformity | IECEx-BVS22.0008/IECEx BKI 07.0023 |
| Marking acc. to ATEX | @2Gxe lT6/Exe ib lCT6/x e b IT6 |
| @ M2 P6 80*C95* | |
| Marking acc. to IECEx | Ex de ia/b m [ia/ib] IIC T4-T6, Ex tD A21 IP66 T80*C |
| Marking acc. to GB | Ex de e ia/ib [ia/ib] mb IIC T4T6 Gb DIP A21 TA 80*C/95°C IP66 |
| Application temperature | -20°C+40°C |
| Rated voltage | -55*C-+55*C(option) |
| Rated current | 690v |
| Connecting terminals | 40A |
| PE-connection terminals | See technical data for components |
| Degree of protection | 2x4mm2 |
| Insulation class | IP66 acc.to EN 60529 |
| Enclosure material | 1 |
| Enclosure colour | Glass-fibre reinforced polyester Black |
Enclosure GHG 44\* 23
GHG44423, GHG44823, GHG44923, GHG44723 series Dimension
Enclosure GHG 44\* 23
GHG44423, GHG44823, GHG44923, GHG44723 series
Dimension
Distance between centres 40mm
Distance between centres 50mm
Distance between centres 60mm
Enclosure GHG 44\* 33
Technical data
| Ex-control stations Typ 444, 448, 449, and 447 stainless steel for individual configuration | |
| EC-type examination certificate | PTB 99 ATEX 1044 1/BVS22ATEX-E-006 |
| IECEx certificate of conformity | IECEx BKI 07.0023 /IECEx-BVS22.0008 |
| GB-certification of conformity | CCC |
| Marking accd. to 2014/34/EU | @ II 2 G Ex de ia/ib m [ia/ib] IC T6 1 |
| @ I 2 D Ex tD A21 IP66/IP65 T80 °C | |
| Marking aced. to IECEx | Ex de ia/ib m [ia/ib] ICT4..T61 |
| Ex tD A21 IP66 T80 *C | |
| Permissible ambient temperature | -20 °C up to +40 °C 1) / -55 °C up to +55 °C (option) |
| Rated voltage Rated current | 690 V AC 40A |
| Connecting terminals | see technical data for built-in components |
| PE-Connecting terminals | 2 x 4 mm2 |
| Protection class | |
| Degree of protection accd. to EN 60529 | IP66 (standard) |
| Cable glands/Gland plates/Enclosure drilling | as ordered acd. to manufacturer's specification |
| Enclosure material | Stainless steel ISl 316 L |
| Enclosure colour | polished |
| Connecting terminals | Type 444 33 |
| max. 20 terminals UT 4 | |
| Dimensions (L x W x H) | 312.5 x 175 x 135 mm |
| Weight (empty) Components arrangement | 3.5 kg with mounting framework |
| 6 mounting areas | |
| Connecting terminals | Type 448 33 max. 30 terminals UT 4 |
| Dimensions (L x W x H) | 312.5 x 312.5 x 135 mm |
| Weight (empty) | 7.5 kg with mounting framework |
| distance 40 mm max. 18 mounting areas | |
| Components arrangement | distance 50 mm max. 15 mounting areas |
| distance 60 mm max. 12 mounting areas | |
| Type 449 33 | |
| Connecting terminals | max. 60 terminals UT 4 |
| Dimensions (L x W x H) | 627 x 312.5 x 135 mm |
| Weight (empty) | 11.5 kg with mounting framework |
| Components arrangement | |
| distance 40 mm max. 36 mounting areas | |
| distance 50 mm max. 30 mounting areas | |
| distance 60 mm max. 24 mounting areas | |
| Connecting terminals | Type 447 33 |
| max. 90 terminals UT 4 | |
| Dimensions (L x W x H) | 941.5 x 312.5 x 135 mm |
| Weight (empty) | 16.5 kg with mounting framework |
| Components arrangement | distance 40 mm max. 54 mounting areas |
| distance 50 mm max. 45 mounting areas | |
| distance 60 mm max. 36 mounting areas | |
Enclosure GHG 44\* 33
Mounting areas I Dimension drawing
±b { x } = fixing dimension
Enclosure GHG 44\* 33
Mounting areas I Dimension drawing
Part II: component
DRT pushbutton and DDT double pushbutton
Technical data
| Marking acc. to ATEX | @x> ll 2 G Ex de lIC/@x>l M2 Ex de l |
| Application temperature | -20°C+40°C |
| -55*C +55*C(option) | |
| Rated voltage | 500V AC |
| Rated current | 16A |
| Rated current gold contacts | 0.4A |
| Switching capacity | 400V/16A AC-1/ 400V/ 4A AC-11 |
| Degree of protection | IP66 acc. to EN 60529 |
| Type of mounting | DIN rail mounting |
| Gasket material | Neoprene (standard) fluoric silicone or viton on request |
| Enclosure colour Grey | |
| 2-Pole Version | |
| Connecting terminals | 2x2.5mm3 |
| Dimensions (L x W x H) | 59x31x45mm |
| Weight | 0.15kg |
| 4-Pole Version | |
| Connecting terminals | 4x2.5mm2 |
| Dimensions (L x W x H) | 59x73x45mm |
| Weight | 0.35kg |
DRT pushbutton and DDT double pushbutton
| Ordering code for component | |||||||
| Code Component | |||||||
| A | Pushutton, for enclosure mounting | ||||||
| Double pushbutton, for enclosure mounting | |||||||
| Code | |||||||
| Contact system Contact | |||||||
| points | 12 c22 | ||||||
| c | |||||||
| 1 | 13 | 16 | |||||
| 1 l21 | |||||||
| 114 j24 | l21 124 | ||||||
| - | |||||||
| -4 | 14 | 17 | |||||
| 23 T | |||||||
| E- | |||||||
| 15 | 18 | ||||||
| - | 121 | ||||||
| E---- | |||||||
| l31 141 | 11 l21 l31 41 | 20 | |||||
| l11 l21 | |||||||
| 34 44 | |||||||
| 1NC+3NO | |||||||
| 111 123 | 133 143 | 11 l23 | |||||
| 12 122 | 3444 | ||||||
| 2NC+2NO | 13444 E-7--7 Et- | ||||||
| 111 l21 | 133 143 | 11 l21 133 43 | |||||
| 112 (22 | |||||||
| N --- | |||||||
| 3NC+1NO | I11 l21 | 131 143 | 11 l21 | 131 43 13444 | |||
| 34,44 | 114,j24 | ||||||
| 4NO | 114,j24 | ...J | |||||
| 113 l23 | 138143 | 113 l23 133 143 | |||||
| Code D1, D2 | Label | Code | |||||
| Inscription | 001 | ||||||
| 0, I, Star, Stop 1 | 003 | ||||||
| 005 | |||||||
| 007 | |||||||
| START | 009 | ||||||
| LANGSAM EMERG.STOP | 011 | ||||||
| ARRET | 014 | ||||||
| AUF | 016 | ||||||
| Neutral whtie | 018 | ||||||
| 0.,Arret,Marche | 020 | ||||||
| DOWN | 025 | ||||||
| ON | 027 | ||||||
| 030 | |||||||
| + Neutral red | |||||||
SLT key-operated pushbutton
Technical data
| Marking acc. to ATEX | @x Il 2 G Ex deIIC/ M2 Ex de |
| Application temperature | -20°C+40°C |
| -55*C +55*C(option) | |
| Rated voltage | 500V AC |
| Rated current | 16A |
| Rated current gold contacts | 0.4A |
| Switching capacity | 400V/16A AC-1/ 400V/ 4A AC-11 |
| Degree of protection | IP66 acc. to EN 60529 |
| Type of mounting | DIN rail mounting |
| Gasket material | Neoprene (standard), fluori ilicone or viton on request |
| Enclosure colour | Grey |
| Lock CEAG1 (others on request) | |
| 2-pole version | |
| Connecting terminals | 2x2.5mm2 |
| Dimensions (L x W x H) | 59x31x45mm |
| Weight | 0.15kg |
| 4-pole version | |
| Connecting terminals | 4x2.5mm² |
| Dimensions (L x W x H) | 59x73x45mm |
| Weight | 0.35kg |
SLT key-operated pushbutton
Ordering code for component
| Code | Component Code | ||||
| A | Key-operated pushbutton SLT | ||||
| Code | Contact system | Contact | Code | ||
| c | 2NC | 11 L21 | Silver contact points Gold contact points 13 | ||
| 2NO | 12 22 13 ()rv | 23 | 16 17 | ||
| 1NO+1NC | 114 13 ()rv | 21 124 | 14 | ||
| 4NO | 114 22 114,j24 ()v | 34 44 | 15 | 18 | |
| 1NC+3NO | l13 l23 142,124 | l33 43 13444 | 20 25 | ||
| 2NC+2NO | 0- | l11 23 | l33 43 34 44 | 21 | 26 |
| 3NC+1NO | l11 l21 12 122 | 133 143 3244 | 22 27 | ||
| 4NC | I11 l21 1222 | l31 43 (32 42 24 | 23 | 28 | |
| Code | Pushbutton not pressed | Key | Pushbutton pressed | Key | Code |
| lockable | removable | lockable | removable | 10 | |
| lockable | removable | lockable | not removable | 11 | |
| lockable | removable | not lockable | not removable | 12 | |
| lockable | not removable | lockable | removable | 13 | |
| not lockable | not removable | lockable | removable | 14 | |
| not lockable | removable | auto lockable | removable | 15 |
SLS key-operated pushbutton
Technical data
| Marking acc. to ATEX | @X II2 G Ex de IIC/M2 Ex de |
| Application temperature | -20°C+40°C |
| -55*C +55*C (option) | |
| Rated voltage | 500V AC |
| Rated current | 16A |
| Rated current gold contacts | 0.4A |
| Switching capacity | 400V/16A AC-1/ 400V/ 4A AC-11 |
| Switching system | Engaging-engaging-engaging |
| Degree of protection | IP66 acc. to EN 60529 |
| Type of mounting | DIN rail mounting |
| Gasket material | Neoprene (standard), fluoric silicone or viton on request |
| Enclosure colour | Grey CEAG1 (others on request) |
| Lock 2-pole version | |
| Connecting terminals | 2x2.5mm2 |
| Dimensions (L x W x H) | 59x31x45mm 0.15kg |
| Weight | |
| 4-pole version | |
| Connecting terminals | 4x2.5mm2 |
| Dimensions (L x W x H) Weight | 59x73x45mm 0.35kg |
SLS key-operated pushbutton
| Code | Component | |||||
| A | Key-operated pushbutton | |||||
| Code | ||||||
| Contact system Contact | Code Silver contact pointsGold contact points | |||||
| c | 2NO 1v--t | I0I | 13/23 | |||
| 45° 90° 135° | 14124 | 04 | 14 | |||
| 101 | ||||||
| 2NO | 0--v | 05 | 15 | |||
| 45°90°135°114124 | ||||||
| 13.23 3343 | ||||||
| 4NO | 0v-++-+v | 24 | 34 | |||
| 45°90°135° | 14_24 34 43 | |||||
| 13 21 33 41 | ||||||
| 2NO | 1 Gr T G | |||||
| 0v-+-+--- | 23 33 | |||||
| 45°90°135°_14_22 | 34 42 | |||||
| 13/23 | 33/43 | |||||
| 4NO | 0v-+-+--+ | |||||
| 25 | 35 | |||||
| 45°90°135° | 14 24 | H!. 34 44 | ||||
| Code | Label | Code |
| 0 | 01 | |
| Fem 0 Ort | 02 | |
| Hand 0 Auto | 03 | |
For example: Key-operated switch, 2NO, silver contact points, label" I O II" SLS5 04 01
SGTE emergency stop pushbutton and SGT mushroom-head pushbutton
Technical data
| Marking acc. to ATEX | @x Il 2 G Ex deIlIC/ M2 Ex de |
| Application temperature | -20°C +40°C |
| -55*C +55*c (option) | |
| Rated voltage | 500V AC |
| Rated current | 16A |
| Rated current gold contacts | 0.4A |
| Switching capacity | 400V/16A AC-1/ 400V/ 4A AC-11 |
| Switching system | Engaging-Engaging-Engaging |
| Degree of protection | IP66 acc. to EN 60529 |
| Type of mounting | DIN rail mounting |
| Gasket material | Neoprene (standard), fluoric silicone or viton on request |
| Enclosure colour Grey | |
| 2-pole version | |
| Connecting terminals | 2x2.5mm2 |
| Dimensions (L x W x H) | 59x31x45mm |
| Weight | 0.15kg |
| 4-pole version | |
| Connecting terminals | 4x2.5mm2 |
| Dimensions (L x W x H) | 59x73x45mm |
| Weight | 0.35kg |
SGTE emergency stop pushbutton and SGT mushroom-head pushbutton
| Ordering code for component | |||||
| Code | Component | Code | |||
| A | Mushroom-head pushbutton | SGT | |||
| Mushroom-head emergency stop pushbuton | SGTE | ||||
| Code | Contact system | Contact | Code | ||
| 1 2 | silver contact points | Gold contact points | |||
| c | 2NC | 13 | 16 | ||
| 12 l22 13 j23 | |||||
| 2NO | t-- | 14 | 17 | ||
| l14 | 124 | ||||
| 13 | |||||
| 21 | |||||
| 1NO+1NC | |||||
| l4 l22 | |||||
| 114,24 | 3444 | ||||
| 4NC | |||||
| EA | |||||
| 113 l23 | l33 l43 | ||||
| 12,24 | |||||
| 1NC+3NO | 134,144 | ||||
| E-/ | |||||
| 11 l23 | 133 143 | ||||
| 134.144 | |||||
| 2NC+2NO | |||||
| 27 | |||||
| 11 l21 | 133 143 | ||||
| 3244 | |||||
| 3NC+1NO | |||||
| 28 | |||||
| l11 l21 | l31 43 | ||||
| 112 (22 | (3242 | ||||
| 4NO | ....... | ||||
| 1 l21 | 131 141 | 29 | |||
| Code | |||||
| D | Label | Inscription | Code | ||
| Emergency stop (German-English) | 1 | ||||
| Emergency stop (German -Franch) | |||||
| 4 | |||||
| O, I, START, STOP 0 | 001 | ||||
| 1 | 002 003 | ||||
| II | 004 | ||||
| 005 | |||||
| STOP | 006 | ||||
| START | 007 | ||||
| LANGSAM | 009 | ||||
| SCHNELL | 010 | ||||
| 012 | |||||
| ARRET | 014 | ||||
| MARCHE | 015 | ||||
| O, I, ret, Marche | |||||
| 020 | |||||
| UP | 024 | ||||
| DOWN | 025 | ||||
| Zu | 026 | ||||
| ON | 027 | ||||
| OFF | 028 | ||||
| + | 030 | ||||
| 031 | |||||
SGTE emergency stop pushbutton and SGT mushroom-head pushbutton
| Code | Label | Colour | Code |
| E | red t | 1 | |
| yellow 2 | 2 | ||
| black2 | 3 |
| Code | Function | Released | Engaged | Unlocking | Code |
| F | not lockable | not lockable | n/a (pushbutton function) | 12 | |
| not lockable | lockable | hand released | 2 | ||
| not lockable | lockable | key released | 3 |
For example: Mushroom-head emergency stop pushbutton, 2NC, " 0 , 1, Start, Stop" label, red, silver contact points, hand-released SGT 0 13 01 1 2
SCT mini-control switch
Technical data
| Marking acc. to ATEX | @x I 2 G Ex de lIC/M2 Ex de |
| Application temperature | -20°C +40°C |
| -55*C -+55*C (option) | |
| Rated voltage | 500V AC |
| Rated current | 16A |
| Rated current gold contacts | 0.4A |
| Switching capacity | 400V/16A AC-1/ 400V/ 4A AC-11 |
| Switching system | Engaging-engaging-engaging |
| Degree of protection | IP66 acc. to EN 60529 |
| Type of mounting | DIN rail mounting |
| Gasket material | Neoprene (standard), fluoric silicone or viton on request |
| Enclosure colour Grey | |
| 2-pole version | |
| Connecting terminals | 2x2.5mm2 |
| Dimensions (L x W x H) | 59x31x45mm |
| Weight | 0.15kg |
| 4-pole version | |
| Connecting terminals | 4x2.5mm2 |
| Dimensions (L x W x H) | 59x73x45mm |
| Weight | 0.35kg |
Ordering code for component
| Code | Component | Code | |||
| A | Mini-control switch | SCT | |||
| Code c | Switching system | Version spring - engaging - spring | Code 4 | ||
| engaging - engaging - engaging | 5 | ||||
| engaging - engaging | 6 | ||||
| spring - engaging - engaging | 7 | ||||
| engaging - engaging - spring | 8 | ||||