Meter Box
Property
●Fiberglass SMC meter box is made by craft of moulding SMC unsaturated polyester resin, Fiberglass reinforced plastics.
●Its specialty has solved the problem of wooden meter box, steel meter box and plastic meter box, such as easy to aging, rust, poor insulation performance, poor cold resistance, poor fire resistance and short service life.
●SMC meter box has good quality of high strength,Lightweight,anti-corrosion,installation fastness,rain proof,preventing electric energy stealing,anti-rust, easy to operate and so on.
SMC meter box can be installed on the pole, hanged on the wall or in the wall. Besides all kinds of mechanical meter or electric meter as well as user's switch and leakage protector can be installed inside.
MCCB Enclosure
| Standard | Comply with IEC 61439-3 |
| Rated voltage | 240/415V |
| Material | Flame retardant plastic or Cold steel |
| Color | Gray |
| Dimension | H400×W300×D170mm H500×W400×D195mm |
Moulded Circuit breaker (MCCB)
Moulded Circuit Breaker (MCCB)
Overview
LMB1moulded case circuit breaker with rated insulation voltage 800V, applied in the power system of AC50(60)Hz, rated voltage 690V and below, ratedcurrent 1250A and below as the transfer not frequently. The circuit breaker has the protection devices of over load, short circuit and under voltage ,it can protect the circuit and power equipment from broken.
The MCCB can be sorted to C type (basic),L type (standard), according to its rated limit short circuit breaking capacity.
The MCCB has the features small volume, breaking capacity high, electric arcing short ,anti-vibration. It is the ideal product for application in land and ship.
The installation can be vertical or level and the standard conforms to IEC60947-2 and GB14048.2
Protection Characteristic
| Ui of release(A) | Thermal breaking release ( | 40for land,45° Cfor ship) | Electromagnetic releasebreaking current(A) | Remark |
| 1.05In(cool station)no breaking time(h) | 1.30(thermal station)breaking time(h) | |||
| 10<In<63 | >=1 | <1 | 10ln ± 20% | Power distribution |
| 63<In<100 | >=2 | <2 | ||
| 100<In<800 | >=2 | <2 | 5ln±20%&10ln±20% |
Main Parameters
| Type | LMB1-63 | LMB1-125 | LMB1-250 | LMB1-400 | LMB1-630 | LMB1-800 |
| Poles | 3 & 4 pole | 3 pole | ||||
| Rated current | 6,10,16,20,2532,40,50,63 | 63,80,100,125 | 125,160,180200,225,250 | 225,250,315350,400 | 400,500,630 | 630,800 |
| Rated voltage Ue V | 400V800VA | |||||
| Rated insulation volt Ui V | ||||||
| Utilization category | ||||||
| Rated limited capacity luc(KA) | 50 | 50 | 50 | 65 | 75 | 100 |
Mini Circuit Breaker (MCB)
Overview
LZC45-63 High breaking mini circuit breaker is mainly used for overload and short-circuit protection. It works in the circuit of 50/60Hz, AC 230/400V with rated current from 1A to 63A. The breaker can be used as a leakage breaker by assembling with leakage tripper. It confirms with IEC60898 standard.
| Rated current In | 1A-63A |
| Pole number | 1P,2P,3P,4P |
| Rated voltage Ue | AC230/400V |
| Rated frequency | 50/60Hz |
| Rated breaking capacity | 3KA/4.5KA |
| Tripping characteristics | B,C,D |
| Mechanical life | 10000 times |
| Electrical life | 4000 times |
Installation chart
Mini Circuit Breaker (MCB)
Overview
C65 mini circuit breaker belongs to the advanced level of the nineties in the international instead of the old generation of C45N. And they also have many merits of high protective grade (up to Ip20), highbreaking capacity, good reliability of sensitive action, convenient multi-pole assorting, long using life etc. They are mainly used for overload and short circuit protection within the circuit of AC 50Hz, 230V in single pole, 40oV in double, three & four poles of lighting distribution system in industry & commerce. Meanwhile, they are also used in turning on & off the electric apparatus and lighting circuit under the normalcondition.
Main technical data
| Type | C65 |
| Number of poles | 1P, 2P, 3P, 4P |
| Rated Current(A) | 1,2,3,4,6,10,16,20,25,32,40,50,63A |
| Breaking Capacity(A) | 6000/10000 |
| Rated Voltage(V) | 230/400V |
| Rated Frequency(Hz) | 50/60Hz |
| Endurance | ≥4000 |
| Circumstance Temp.(℃) | -5℃~+40℃ |
| Electrical Life | ≥6000 |
| Mechanical Life | ≥20000 |
| Terminal protection | IP20 |
| Test | Type | Current | Start state | Tripping/no tripping time | Exected result | Note |
| A | C | 1.05 ln | Cold | t≥1h | Not-trip | The current rise toexpected valuewithin 5s |
| B | c | 1.30 ln | Follow test A | t<1h | ||
| C | C | 7ln | Cold | t≥0.1s | Trip | |
| D | C | 15 In | Cold | t<0.1s |
MV Installation Diagram
Line Hardware
Application
●The connection fittings are used to connect and combine insulators, suspension clamps, tension clamps and protective fittings into suspension or tension strings (groups).
●The meaning of the letters in the product model: q-ball head hanging ring P-plane (parallel) contact w-bowl head s-double U-U L-joint plate, pull rod, diamond z-right angle y-extension b-plate t-adjustment.
●Classification and application: U-shaped hanging ring, double plate, right angle hanging plate, extension ring, U-shaped screw and other fittings are called general fittings, which are used for the connection between insulator strings and fittings, between clamps and insulator strings, and between ground wires and towers. Ball head hanging ring and bowl head hanging plate are special fittings for connecting ball and socket insulators
Standard
ISO 1461:2009 Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods
●ISO4948-1 Steels—Classification—Part 1: Classification of steels into unalloyed and alloy steels based on chemical composition
●BS 3288 Insulator and conductor fittings for overhead power lines
Q/QP Ball Eye
| Type | Dimension(mm) | Link Marker | Failure Load(KN) | ||||
| d | ① | b | d1 | h | |||
| Q-7 | 17 | 22 | 16 | 33.3 | 50 | 16 | 70 |
| QP-7 | 17 | 22 | 16 | 33.3 | 50 | 16 | 70 |
| QP-10 | 17 | 22 | 16 | 33.3 | 50 | 16 | 100 |
| QP-12 | 17 | 24 | 16 | 33.3 | 50 | 16 | 120 |
| QP-16 | 21 | 26 | 20 | 41 | 60 | 20 | 160 |
Line Hardware
QH Ball Eye
| Type | Dimension(mm) | Link Marker | Failure Load(KN) | ||||
| b | d | d1 | H | H1 | |||
| QH-7 | 16 | 17 | 33.3 | 100 | 57 | 16 | 70 |
| QH-10 | 18 | 17 | 33.3 | 110 | 57 | 16 | 100 |
| QH-12 | 19 | 17 | 33.3 | 120 | 65 | 16 | 120 |
| QH-16 | 18 | 21 | 41 | 127 | 45 | 20 | 160 |
Q-U Ball Eye
| Type | Dimension(mm) | Failure Load(KN) | ||||
| H | d | d1 | M | C | ||
| Q-7U | 80 | 17 | 33.3 | 16 | 18 | 70 |
| Q-10U | 80 | 17 | 33.3 | 18 | 20 | 100 |
| Q-12U | 95 | 17 | 33.3 | 22 | 22 | 120 |
| Q-16U | 80 | 21 | 41 | 24 | 22 | 160 |
Line Hardware
W Socket Eye
Material:Hot dip galvanized steel W type pin made of stainless steel
| Type | Dimension(mm) | Link Marker | Failure Load(KN) | ||||
| b | C1 | C2 | H | ① | |||
| W-7A | 16 | 19.2 | 34.5 | 70 | 20 | 16 | 70 |
| W-7B | 16 | 19.2 | 34.5 | 115 | 20 | 16 | 70 |
| W-10 | 18 | 19.2 | 34.5 | 85 | 20 | 16 | 100 |
| W-12 | 20 | 19.2 | 34.5 | 90 | 24 | 16 | 120 |
WS Socket Eye
Material:Hot dip galvanized steel W type pin made of stainless steel R type pin made of stainless steel
| Type | Dimension(mm) | Link Marker | Failure Load(KN) | ||||
| C | C1 | C2 | M | H | |||
| WS-7 | 20 | 19.2 | 34.5 | 16 | 70 | 16 | 70 |
| WS-10 | 20 | 19.2 | 34.5 | 18 | 85 | 16 | 100 |
| WS-12 | 24 | 19.2 | 34.5 | 22 | 85 | 16 | 120 |
| WS-16 | 26 | 23.0 | 42.5 | 24 | 95 | 20 | 160 |
Line Hardware
WSY Socket Clevis
Material:Hot dip galvanized steel W type pin made of stainless steel
| Type | Dimension(mm) | Link Marker | Failure Load(KN) | |||
| C1 | C2 | M | R | |||
| WSY-21 | 42.2 | 23 | 27 | 100 | 20 | 210 |
| WSY-30 | 51 | 27.5 | 30 | 110 | 24 | 300 |
Socket Thimble
Material:Hot dip galvanized steel R type pin made of stainless steel
| Type | Dimension(mm) | Failure Load(KN) | |||||
| L | L1 | L2 | L3 | L4 | H | ||
| DDT-07 | 75 | 55 | 35 | 37 | 23 | 97 | 70 |
Line Hardware
U Anchor Shackles
Material:Hot dip galvanized steel R type pin made of stainless steel
| Type | Dimension(mm) | Failure Load(KN) | ||||
| C | M | d | H | R | ||
| U-7 | 20 | 16 | 16 | 80 | 10 | 70 |
| U-10 | 22 | 18 | 18 | 85 | 11 | 100 |
| U-12 | 24 | 22 | 20 | 90 | 12 | 120 |
| U-16 | 26 | 24 | 22 | 95 | 13 | 160 |
UL Anchor Shackles
Material:Hot dip galvanized steel W type pin made of stainless steel
| Type | Dimension(mm) | Failure Load(KN) | ||||
| C | M | d | H | R | ||
| UL-7 | 20 | 16 | 16 | 120 | 10 | 70 |
| UL-10 | 22 | 18 | 18 | 140 | 11 | 100 |
| UL-12 | 24 | 22 | 20 | 140 | 12 | 120 |
| UL-16 | 26 | 24 | 22 | 140 | 13 | 160 |
Line Hardware
U-Bolts
Material:Hot dip galvanized steel R type pin made of stainless steel
| Type | Dimension(mm) | Failure Load(KN) | ||||
| C | M | H1 | H2 | |||
| U-1880 | 80 | 18 | 110 | 75 | 35 | |
| U-2080 | 80 | 20 | 120 | 80 | 47 | |
| U-2280 | 80 | 22 | 130 | 90 | 57 | |
Z Link Plate
Material:Hot dip galvanized steel R type pin made of stainless steel
| Type | Dimension(mm) | Failure Load(KN) | ||||
| C1 | C2 | M | H | |||
| Z-7 | 18 | 18 | 16 | 80 | 70 | |
| Z-10 | 20 | 20 | 18 | 80 | 100 | |
| Z-12 | 20 | 24 | 22 | 100 | 120 | |
| Z-16 | 26 | 26 | 24 | 100 | 160 | |
Line Hardware
PS Clevise
Material:Hot dip galvanized steel R type pin made of stainless steel
| Type | Dimension(mm) | Failure Load(KN) | ||||
| C | b | M | H | ① | ||
| PS-7 | 18 | 16 | 16 | 90 | 20 | 70 |
| PS-10 | 18 | 18 | 18 | 100 | 22 | 100 |
| PS-12 | 24 | 20 | 22 | 95 | 24 | 120 |
| PS-16 | 26 | 24 | 24 | 155 | 26 | 160 |
PD Link Clevis
| Type | Dimension(mm) | Failure Load(KN) | ||||
| φ | H | b | L | R | ||
| PD-7(PD-0770) | 18 | 70 | 16 | 40 | 26 | 70 |
| PD-10(PD-1080) | 20 | 80 | 16 | 36 | 26 | 100 |
| PD-12(PD-12100) | 24 | 100 | 16 | 50 | 24 | 120 |
| PD-16 | 26 | 100 | 18 | 60 | 35 | 160 |
Line Hardware
P Extension Link Clevis
Material:Hot dip galvanized steel R type pin made of stainless steel
| Type | Dimension(mm) | Failure Load(KN) | |||
| b | C | M | H | ||
| P-7 | 6 | 18 | 16 | 70 | 70 |
| P-10 | 8 | 20 | 18 | 80 | 100 |
| P-12 | 10 | 24 | 22 | 90 | 120 |
| P-16 | 12 | 26 | 24 | 100 | 160 |
D Shackles
Material:Hot dip galvanized steel R type pin made of stainless steel
| Dimension(mm) | Failure Load(KN) | ||||||
| A | C | D | E | F | R | S | |
| 70 | 19 | 35 | 18 | 9.5 | 16 | 16 | 70 |
| 76 | 21 | 54 | 22 | 13 | 19 | 19 | 120 |
Line Hardware
Ball-ended Hook and pig tail hook
Material:Hot Dipped galvanized Steel
Tension Clamp
Tension clamp refers to the hardware used to fix the conductor to bear the tension of the conductor and hang the conductor to the tension string or tower
NLL/NLD Strain Clamps
Material:
Body: NLL are made of aluminum NLD are made of hot dip galvanized steel U bolt/ bolt: Hot dip galvanized steel R Pin: Stainless Steel
| Type | U bolt | Applicable conductordiameter(mm²) | |
| Qty | Diameter | ||
| NLL-1 | 2 | M12 | 5.0-15.5 |
| NLL-2 | 2 | M12 | 8.2-17.0 |
| NLL-3 | 3 | M14 | 11.4-20.0 |
| NLL-4 | 4 | M16 | 13.6-25.0 |
| NLD-1 | 2 | M12 | 5.0-10.0 |
| NLD-2 | 3 | M12 | 10.0-14.0 |
| NLD-3 | 4 | M16 | 14.0-18.0 |
| NLD-4 | 4 | M16 | 18.1-23.0 |
NY Hydraulic Compression Type Strain Clamps
| Type | Applicable conductordiameter(mm²) |
| NY-95/15 | LGJ-95/15 |
| NY-95/20 | LGJ-95/20 |
| NY-120/20 | LGJ-120/20 |
| NY-120/25 | LGJ-120/25 |
| NY-150/20 | LGJ-150/20 |
| NY-150/25 | LGJ-150/25 |
| NY-150/35 | LGJ-150/35 |
| NY-185/25 | LGJ-185/25 |
| NY-185/30 | LGJ-185/30 |
| NY-185/45 | LGJ-185/45 |
| Type | Applicable conductordiameter(mm) | Failure Load ( KN) |
| CGU-2 | 7.0-12.4 | 40 |
| CGU-3 | 12.4-17.0 | 40 |
| CGU-4 | 19.0-21.5 | 40 |
| CGU-5 | 24.2-33.0 | 70 |
| Type | Applicable conductordiameter(mm) | Failure Load(KN) |
| XGU-1 | 5.0-7.0 | 40 |
| XGU-2 | 7.1-13.0 | 40 |
| XGU-3 | 13.1-21.0 | 40 |
| XGU-4 | 21.1-26.0 | 40 |
Suspension Clamp
The suspension clamp is mainly used for overhead power lines or substations, and the conductor and lightning wire are hungon the insulator string or the lightning wire is hung on the tower through the connecting hardware; It is made of Horse Iron and aluminum alloy.
CGU/XGU Suspension Clamps
Material:
Body & Keeper: CGU are made of aluminum. XGU are made of hot dip galvanized steel. U bolt/ bolt: Hot dip galvanized steel R Pin: Stainless Steel
Preformed dead end clamp
Preformed Guy Grip
Material:Hot-dip galvanized steel wire
| Type | Applicableconductor (mm²) | Length(mm) | Rod diameter(mm) | No.of rods |
| LRNL-50/LJ | AAAC/AAC 50 | 685 | 3.00 | 3 |
| LRNL-100/LJ | AAAC/AAC 100 | 800 | 3.50 | 3 |
| LRNL-150/LJ | AAAC/AAC 150 | 889 | 4.00 | 4 |
| LRNL-200/LJ | AAAC/AAC 200 | 1016 | 4.00 | 5 |
| LRNL-50/8 | ACSR 50/8 | 685 | 3.00 | 3 |
| LRNL-100/8~20 | ACSR 100/8~20 | 876 | 3.50 | 4 |
| LRNL-150/8~35 | ACSR 150/8~35 | 1016 | 4.00 | 5 |
| LRNL-200/12~50 | ACSR 200/12~50 | 1155 | 4.80 | 5 |
PG Clamp And Connector
APG PG Clamp
| Type | Bolts | Applicable conductor diameter(mm²) | |
| Qty | Diameter | ||
| APG-A1 | 1 | M8 | 16-70 |
| APG-A2 | 1 | M8 | 16-150 |
| APG-B1 | 2 | M6 | 16-35 |
| APG-B2 | 2 | M8 | 16-70 |
| APG-B3 | 2 | M8 | 16-150 |
| APG-C1 | 3 | M8 | 16-70 |
| APG-C2 | 3 | M8 | 16-150 |
| APG-C3 | 3 | M10 | 25-240 |
| Type | Bolts | Applicable conductor diameter(mm²) | ||
| Qty | Diameter | AL | CU | |
| CAPG-A1 | 1 | M8 | 16-70 | 6-50 |
| CAPG-A2 | 1 | M8 | 25-150 | 10-95 |
| CAPG-B1 | 2 | M8 | 16-70 | 6-50 |
| CAPG-B2 | 2 | M8 | 25-150 | 10-95 |
| CAPG-B3 | 2 | M10 | 25-240 | 25-200 |
| CAPG-B4 | 2 | M10 | 35-300 | 35-240 |
| CAPG-C2 | 3 | M8 | 25-150 | 10-95 |
| CAPG-C3 | 3 | M10 | 25-240 | 25-200 |
PG Clamp And Connector
JB PG Clamp(Aluminum wire,ACSR)
Material:The main body is made of aluminum, and the bolt is hot-dip galvanized steel
| Type | Bolts | Applicable conductordiameter(mm²) | |
| Qty | Diameter | ||
| JB-0 | 2 | M10 | 16-25 |
| JB-1 | 2 | M12 | 35-50 |
| JB-2 | 3 | M12 | 70-95 |
| JB-3 | 3 | M16 | 120-150 |
| JB-4 | 3 | M16 | 185-200 |
JBT PG Clamp
Material:The main body is made of copper, and the bolt is hot-dip galvanized steel
| Type | Bolts | Applicable conductordiameter(mm²) | |
| Qty | Diameter | ||
| JBT-10~70 | 2 | M8 | 10-70 |
| JBT-10~70 | 3 | M8 | 10-70 |
| JBT-16~120 | 2 | M10 | 16-120 |
| JBT-16~120 | 3 | M10 | 16-120 |
| JBT-50~240 | 2 | M10 | 50-240 |
| JBT-50~240 | 3 | M10 | 50-240 |
| JBT-00 | 2 | M10 | 16-25/16-25 |
| JBT-10 | 2 | M10 | 35-50/16-25 |
| JBT-11 | 2 | M10 | 35-50/35-50 |
| JBT-21 | 2 | M12 | 70-95/35-50 |
| JBT-22 | 2 | M12 | 70-95/70-95 |
| JBT-31 | 3 | M12 | 120-150/35-50 |
JBTL PG Clamp
Material:The body is made of aluminum and copper, and the bolt is hot-dip galvanized steel
| Type | Bolts | Applicable conductordiameter(mm²) | |
| Qty | Diameter | ||
| JBTL-10~70 | 2 | M8 | 10-70 |
| JBTL-10~70 | 3 | M8 | 10-70 |
| JBTL-16~120 | 2 | M10 | 16-120 |
| JBTL-16~120 | 3 | M10 | 16-120 |
| JBTL-50~240 | 2 | M10 | 50-240 |
| JBTL-50~240 | 3 | M10 | 50-240 |
PG Clamp And Connector
Aluminium PG Clamp
| Type | Dimension(mm) | ||||
| L | W | H | M | No. of bolt | |
| 25-70mm² | 75 | 40 | 20 | 10 | 2 |
| 70-150mm2 | 98 | 54 | 34 | 10 | 3 |
| Up-to 300mm² | 160 | 60 | 32 | 14 | 4 |
Aluminium Line Tap Connector
| Type | Dimension(mm) | ||||
| M | L | W | H | 1 | |
| 50mm² | 8 | 32 | 22 | 42 | 10 |
| 100mm² | 12 | 48 | 29 | 58 | 15 |
DL Aluminium Lug
| Type | ① | D | d | L | W | S |
| DL-10 | 8.5 | 10 | 5.5 | 65 | 16 | 2.8 |
| DL-16 | 8.5 | 11.8 | 7.6 | 70 | 16 | 3 |
| DL-25 | 8.5 | 12 | 8 | 76 | 18 | 3.1 |
| DL-35 | 10.5 | 14 | 8.5 | 84 | 20.6 | 3.1 |
| DL-50 | 10.5 | 15.6 | 9.8 | 90 | 23.2 | 4.4 |
| DL-70 | 12.5 | 17.8 | 12 | 104 | 25.6 | 4.4 |
| DL-95 | 12.5 | 20.2 | 13.8 | 108 | 27.6 | 4.9 |
| DL-120 | 14.5 | 21.6 | 15.2 | 118 | 30.2 | 5.4 |
| DL-150 | 14.5 | 24.4 | 16.8 | 125 | 34.4 | 5.8 |
| DL-185 | 16.5 | 27 | 19 | 129 | 37.4 | 5.8 |
| DL-240 | 16.5 | 30 | 20.8 | 138 | 40.4 | 7 |
DT Copper Lug
| Type | φ | D | d | L | W | S |
| DT-10 | 8.5 | 9 | 5.2 | 63 | 16 | 2.2 |
| DT-16 | 8.5 | 10 | 6.2 | 66.2 | 16 | 2.2 |
| DT-25 | 8.5 | 11.2 | 7 | 72 | 18 | 2.6 |
| DT-35 | 10.5 | 12.2 | 8.2 | 75.8 | 20 | 2.6 |
| DT-50 | 10.5 | 14 | 9.8 | 86.2 | 23 | 3.4 |
| DT-70 | 12.5 | 16.2 | 11.4 | 93 | 26 | 4 |
| DT-95 | 12.5 | 18 | 13.8 | 103 | 28 | 4 |
| DT-120 | 14.5 | 20 | 14.8 | 110.4 | 30 | 4.6 |
| DT-150 | 14.5 | 22 | 17.2 | 117.2 | 34 | 5.2 |
| DT-185 | 16.5 | 24 | 19 | 124 | 37 | 5.8 |
| DT-240 | 16.5 | 27 | 20.8 | 135 | 40 | 6.4 |
Lug
DTL Bimetal Lug
| Type | ① | D | d | L | W | S |
| DTL-1-16 | 8.5 | 10 | 5.5 | 70 | 16 | 3.0 |
| DTL-1-25 | 8.5 | 12 | 7.0 | 75 | 18 | 3.5 |
| DTL-1-35 | 10.5 | 14 | 8.5 | 85 | 20 | 3.5 |
| DTL-1-50 | 10.5 | 16 | 9.5 | 90 | 23 | 4.0 |
| DTL-1-70 | 12.5 | 18 | 12.0 | 102 | 26 | 4.5 |
| DTL-1-95 | 12.5 | 21 | 13.0 | 112 | 28 | 5.0 |
| DTL-1-120 | 14.5 | 23 | 15.0 | 120 | 30 | 5.5 |
| DTL-1-150 | 14.5 | 25 | 16.0 | 126 | 34 | 6.0 |
| DTL-1-185 | 16.5 | 27 | 18.0 | 133 | 37 | 6.5 |
| DTL-1-240 | 16.5 | 30 | 20.0 | 140 | 40 | 7.5 |
DTL Bimetal Lug
| Type | ① | D | d | L | W | S |
| DTL-2-16 | 10.5 | 16 | 6 | 80 | 20 | 3 |
| DTL-2-25 | 10.5 | 16 | 7 | 80 | 20 | 3 |
| DTL-2-35 | 10.5 | 16 | 8.5 | 80 | 20 | 3 |
| DTL-2-50 | 13 | 20 | 10 | 90 | 24 | 4 |
| DTL-2-70 | 13 | 20 | 11.5 | 90 | 24 | 4 |
| DTL-2-95 | 13 | 20 | 13.5 | 90 | 24 | 4 |
| DTL-2-120 | 13 | 25 | 15 | 115 | 30 | 4.5 |
| DTL-2-150 | 13 | 25 | 16.5 | 115 | 30 | 4.5 |
| DTL-2-185 | 13 | 32 | 18.5 | 122 | 35 | 6 |
| DTL-2-240 | 13 | 32 | 21 | 122 | 35 | 6 |
SC Tinned Copper Lug
| Type | φ | D | d | L | W | S |
| SC-10 | 8.5 | 8 | 5.8 | 39 | 11.5 | 2.2 |
| SC-16 | 10.5 | 9 | 6.5 | 42 | 14.5 | 2 |
| SC-25 | 8.5 | 10 | 7.6 | 47 | 14.5 | 2.4 |
| SC-35 | 10.5 | 11 | 8.5 | 52 | 15.5 | 2.5 |
| SC-50 | 10.5 | 13 | 10 | 54 | 19 | 3 |
| SC-70 | 12.5 | 16 | 12 | 62 | 23 | 4 |
| SC-95 | 12.5 | 18 | 14 | 64 | 26 | 4 |
| SC-120 | 12.5 | 19 | 15 | 72 | 27.5 | 4 |
| SC-185 | 16.5 | 24 | 18.8 | 86 | 34.5 | 5 |
| SC-240 | 16.5 | 26 | 21 | 91 | 37.5 | 5 |
| Type | Section area(mm²) | Dimension(mm) | LB(mm) | Bolt No. | AF(mm) | |||
| L1 | L2 | D1 | D2 | |||||
| BLMT-6/50-13 | 6-50 | 50 | 20 | 18 | 10 | 13 | 1 | 13 |
| BLMT-25/95-13 | 25-95 | 60 | 30 | 24 | 12.8 | 13 | 1 | 13 |
| BLMT-25/95-17 | 25-95 | 60 | 30 | 24 | 12.8 | 17 | 1 | 13 |
| BLMT-35/150-13 | 35-150 | 86 | 36 | 28 | 15.8 | 13 | 1 | 17 |
| BLMT-35/150-17 | 35-150 | 86 | 36 | 28 | 15.8 | 17 | 1 | 17 |
| BLMT-95/240-13 | 95-240 | 112 | 60 | 33 | 20 | 13 | 2 | 19 |
| BLMT-95/240-17 | 95-240 | 112 | 60 | 33 | 20 | 17 | 2 | 19 |
| BLMT-95/240-21 | 95-240 | 112 | 60 | 33 | 20 | 21 | 2 | 19 |
| BLMT-120/300-13 | 120-300 | 120 | 65 | 37 | 24 | 13 | 2 | 22 |
| BLMT-120/300-17 | 120-300 | 120 | 65 | 37 | 24 | 17 | 2 | 22 |
| BLMT-185/400-13 | 185-400 | 137 | 80 | 42 | 25.5 | 13 | 3 | 22 |
| BLMT-185/400-17 | 185-400 | 137 | 80 | 42 | 25.5 | 17 | 3 | 22 |
| BLMT-185/400-21 | 185-400 | 137 | 80 | 42 | 25.5 | 21 | 3 | 22 |
| BLMT-500/630-13 | 500-630 | 150 | 95 | 50 | 33 | 13 | 3 | 27 |
Joint And Connector
JY Cable Joint
| Type | Cable range Applicable | Dimension(mm) | Rated Failure Load(KN) | |||||
| L | D | d | L1 | D1 | d1 | |||
| JY-70/10 | JKLGYJ-70/10 | 360 | 25 | 13 | 110 | 12 | 4.5 | 21 |
| JY-95/15 | JKLGYJ-95/15 | 430 | 26 | 15 | 130 | 14 | 5.7 | 31.5 |
| JY-120/20 | JKLGYJ-120/20 | 430 | 30 | 16 | 130 | 14 | 6.2 | 36.9 |
| JY-150/25 | JKLGYJ-150/25 | 500 | 30 | 18.5 | 150 | 14 | 7.0 | 48.7 |
| JY-185/25 | JKLGYJ-185/25 | 520 | 32 | 20.5 | 150 | 14 | 7.0 | 53.5 |
| JY-240/30 | JKLGYJ-240/30 | 570 | 36 | 23 | 170 | 16 | 7.9 | 68 |
JBE Repair Sleeves For ACSR Conductor
| Type | Cable range Applicable | |||
| Dimension(mm) | ||||
| D | L | R | ||
| JBE-35/6 | LGJ-35/6 | 16 | 120 | 4.8 |
| JBE-50/8 | LGJ-50/8 | 18 | 130 | 5.5 |
| JBE-70/10 | LGJ-70/10 | 22 | 130 | 6.5 |
| JBE-95/15~20 | LGJ-95/15/20 | 24 | 140 | 8.0 |
| JBE-120/7 | LGJ-120/7 | 26 | 140 | 8.0 |
| JBE-120/20~25 | LGJ-120/20/25 | 26 | 140 | 8.6 |
| JBE-150/8~20 | LGJ-150/8/20 | 30 | 140 | 9.1 |
| JBE-150/25~35 | LGJ-150/25/35 | 30 | 170 | 9.5 |
| JBE-185/10~30 | LGJ-185/10/30 | 32 | 170 | 10.3 |
| JBE-185/45 | LGJ-185/45 | 34 | 170 | 10.8 |
Joint And Connector
GL-G Aluminium Connecting Pipe(Passing Though)
| Type | L | D | d |
| GL-G-16 | 65 | 10 | 5.5 |
| GL-G-25 | 70 | 12 | 7 |
| GL-G-35 | 75 | 14 | 8.5 |
| GL-G-50 | 80 | 16 | 10 |
| GL-G-70 | 90 | 18 | 11.5 |
| GL-G-95 | 95 | 21 | 13.5 |
| GL-G-120 | 100 | 23 | 15 |
| GL-G-150 | 105 | 25 | 16.5 |
| GL-G-185 | 110 | 27 | 18.5 |
| GL-G-240 | 120 | 30 | 21 |
GT-G Copper Connecting Pipe(Passing Though)
Material:Copper
| Type | L | D | d |
| GT-G-16 | 56 | 9 | 6 |
| GT-G-25 | 60 | 10 | 7 |
| GT-G-35 | 64 | 11 | 8.5 |
| GT-G-50 | 72 | 13 | 10 |
| GT-G-70 | 78 | 15 | 11 |
| GT-G-95 | 85 | 18 | 13 |
| GT-G-120 | 90 | 20 | 15 |
| GT-G-150 | 94 | 23 | 17 |
| GT-G-185 | 100 | 25 | 19 |
| GT-G-240 | 110 | 27 | 21 |
Copper-Aluminium connecting tubes
| Type | D | d | D1 | d1 | L | L1 | L2 |
| GTL-10 | 9 | 4.5 | 9 | 4.2 | 70 | 28 | 28 |
| GTL-16 | 9 | 5.5 | 9 | 5.0 | 75 | 31 | 28 |
| GTL-25 | 12 | 7.0 | 10 | 5.5 | 80 | 32 | 30 |
| GTL-35 | 14 | 8.5 | 11 | 7.0 | 90 | 37 | 32 |
| GTL-50 | 16 | 9.5 | 13 | 8.5 | 95 | 42 | 34 |
| GTL-70 | 18 | 12.0 | 15 | 9.6 | 100 | 46 | 35 |
| GTL-95 | 21 | 13.0 | 17 | 12.0 | 110 | 50 | 41 |
| GTL-120 | 23 | 15.0 | 19 | 13.0 | 112 | 52 | 43 |
| GTL-150 | 25 | 16.0 | 21 | 15.0 | 118 | 55 | 46 |
LV ABC Aerial Electrical Fittings
Insulation piercing connector(IPC)
General
●Piercing connector, simple installation, need not strip the cable coat.
Moment nut, piercing pressure is constant, keep good electric connection and make no damage to lead.
●Self-seam frame, wetproof, waterproof, and anti-corrosion, extend the using life of insulated lead and connector
●Adopted special connecting tablet, apply to joint of Cu(Al) and Cu(Al) or Cu and Al
Small electric connecting resistance, connecting resistance less than 1.1 times of the resistance of branch conductor with the same length.
Special insulated case body, resistance to illumination and environmental aging, the insulation strength can up to 12KV.
Arc surface design, apply to connection with the same(different) diameter, wide connection scope(0.75mm2-400mm2).
Simple installation
How to choosing Insulation piercing connector
●Simple installation
Con be branch of cable without striping the insulated coat and the joint is completely insulated. Make branch in the random location of cable without cutting off the main cable. Simple and reliable installati just need sleeve spanner, can be installed with on live line
The joint has good resistance to distortion, quake, fire, wet, electrochemical corrosion and aging, need no maintenance. Has been used successfully for 30years
●Economical cost
Small installation space, save the cost of bridge and land construction. In structural application, there need no terminal box, junction box and return wire of cable, save cable cost. The cost of cables and clamps is lower than other power supply system
LV ABC Aerial Electrical Fittings
Product type and application scope
| Type | Material of teeth | Main line(mm²) | Branch line(mm²) | Nominal current(A) | Piercing depth |
| LR756 | Al/Cu/Bimetallic | 0.75~6 | 0.75~6 | 41 | 1-1.5 |
| LR041 | Al/Cu/Bimetallic | 1.5~35 | 1.5~10 | 41 | 1.5-2 |
| LR101 | Al/Cu/Bimetallic | 1.5~2.5 | 1.5~10 | 55 | 1.5-2 |
| LREP | Al/Cu/Bimetallic | 16~95 | 1.5~10 | 55 | 1-2 |
| LR2-95 | Al/Cu/Bimetallic | 16~95 | 4~54.6 | 160 | 1.5-2 |
| LR2-150 | Al/Cu/Bimetallic | 50~150 | 6~54.6 | 162 | 1.5-2.5 |
| LR3-95 | Al/Cu/Bimetallic | 16~95 | 16~95 | 198 | 1.5-2 |
| LR4-150 | Al/Cu/Bimetallic | 50~150 | 50~150 | 219 | 1.5-2.5 |
| LR6 | Al/Cu/Bimetallic | 120~240 | 25~120 | 360 | 1.5-2.5 |
| LR7 | Al/Cu/Bimetallic | 150~240 | 10~25 | 336 | 1.5-2.5 |
| LR240 | Al/Cu/Bimetallic | 95~240 | 95~240 | 1040 | 1.5-2.5 |
| LR300 | Al/Cu/Bimetallic | 300 | ANY | 1040 | 1.5-2.5 |
| LR400 | Al/Cu/Bimetallic | 400 | ANY | 1040 | 1.5-2.5 |
| Type | Material of teeth | Main line(mm²) | Branch line(mm²) | No. Bolt |
| JBC-1 | Al/Cu/Bimetallic | 35~70 | 6~35 | 1 |
| JBC-2 | Al/Cu/Bimetallic | 35~150 | 35~150 | 1 |
| JBC50-240 | Al/Cu/Bimetallic | 50~240 | 50~240 | 2 |
LV ABC Aerial Electrical Fittings
Product type and application scope
| Type | Conductor Range (mm²) | No. Bolt | |
| Main | Tap | ||
| IPC3.1 | 16-95 | 10-25 | 1 |
| IPC3.2 | 70-95 | 70-95 | 1 |
| IPC3.3 | 120-185 | 16-25 | 1 |
| IPC3.4 | 70-185 | 70-185 | 2 |
| TTD121F | 25-95 | 2.5-25 | 1 |
| TTD151F | 25-95 | (2.5)6-35 | 1 |
| TTD201F | 35-95 | 25-95 | 1 |
| TTD281F | 50-185 | 6-35 | 1 |
| TTD282F | 25-95 | 25-35 | 1 |
| TTD451F | 95-240 | 95-240 | 2 |
LV ABC Aerial Electrical Fittings
Product type and application scope
| Type | ||
| Conductor Range (mm²) | ||
| Main | Tap | |
| CT-1 | 6-95 | 1.5-6 |
| CT-2 | 6-150 | 2.5-25 |
| CT-3 | 6-150 | 4-35 |
| CT-4 | 25-150 | 25-95 |
| CT-5 | 25-150 | 16-95 |
End Cap
| Type | Conductor cross-section(mm²) |
| PC6-35 | 6-35 |
| PC35-70 | 35-70 |
| PC70-95 | 70-95 |
| PC95-120 | 95-120 |
LV ABC Aerial Electrical Fittings
MJPT Pre-insulated sleeve
Product property
MJPT is designed to connect the insulated cable (include ABC cable) in aerial distribution network. It is in accordance with NFC33-021. The sleeve is with some tension.
And its cap can prevent the water into the barrel. It is colored differently to distinguish the cable sizes.Marked with type, cable size, die size, inner cable length and number of crimping.
| Type | Cable size (mm²) | Plastic sleeve diameter(mm) | Length(mm) | |
| A | B | C | L | |
| MJPT 16/16 | 16 | 16 | 20 | 98.5 |
| MJPT 25/25 | 25 | 25 | 20 | 98.5 |
| MJPT 35/35 | 35 | 35 | 20 | 98.5 |
| MJPT 50/50 | 50 | 50 | 20 | 98.5 |
| MJPT 70/70 | 70 | 70 | 20 | 98.5 |
| MJPT 95/95 | 95 | 95 | 20 | 98.5 |
MJPB Pre-insulated sleeve
Product property
MJPB is designed to connect the insulated cable (include ABC cable). It is in accordance with NFC33-021. The sleeve is without tension.
And its cap can prevent the water into the barrel. It is colored differently to distinguish the cable size.Marked with type, cable size, die size, inner cable length and number of crimping.
| Type | Cable size (mm²) | Plastic sleeve diameter(mm) | Length(mm) | |
| A | B | C | L | |
| MJPB 6/16 | 6 | 16 | 20 | 98.5 |
| MJPB 10/16 | 10 | 16 | 20 | 98.5 |
| MJPB 16/16 | 16 | 16 | 20 | 98.5 |
| MJPB 16/25 | 16 | 25 | 20 | 98.5 |
| MJPB 25/25 | 25 | 25 | 20 | 98.5 |
LV ABC Aerial Electrical Fittings
MJPN Pre-insulated sleeve
Product property
MJPTN is designed to connect the neutral messenger in aerial bundled cable. It is in accordance with NFC33-021. The sleeve is with full tension.
And its cap can prevent the water into the barrel. It is colored differently to distinguish the cable size.Marked with type, cable size, die size, inner cable length and number of crimping.
| Type | Cable size (mm²) | Plastic sleeve diameter(mm) | Length(mm) | |
| A | B | C | L | |
| MJPTN 54.6/54.6 | 54.6 | 54.6 | 20 | 172.5 |
| MJPTN 54.6/70 | 54.6 | 70 | 20 | 172.5 |
| MJPTN 70/70 | 70 | 70 | 20 | 172.5 |
| MJPTN 95/95D | 95 | 95 | 20 | 172.5 |
CPTAU Pre-insulated bimetal lug
Product property
CPTAU is designed to connect the insulated cable (include ABC cable). It is in accordance with NFC33-021.
The waterproof cap can prevent the water into the barrel. It is colored differently to distinguish the cable size.Marked with type, cable size, die size, inner cable length and number of crimping.
| Type | Dimension (mm) | Length(mm) | ||
| C | B | ① | L | |
| CPTAU16-10 | 16 | 20 | 10.5 | 73 |
| CPTAU25-12 | 20 | 24 | 13 | 98.5 |
| CPTAU35-12 | 20 | 24 | 13 | 98.5 |
| CPTAU50-12 | 20 | 24 | 13 | 98.5 |
| CPTAU54.6-12 | 20 | 24 | 13 | 98.5 |
| CPTAU70-12 | 20 | 24 | 13 | 98.5 |
| CPTAU95-12 | 20 | 24 | 13 | 98.5 |
LV ABC Aerial Electrical Fittings
Anchoring Bracket
Product property
Anchoring ABC cables with neutral messenger on poles(wood, concrete etc), Excellent in industrial and saline environment. Fixed by 2×(14mm or 16mm) bolts or two stainless straps 0.75X20mm. It is in accordance with NFC 33-040.
Material:High strength aluminium alloy by casting
The universal hook LR96,LR97and LR98 is usedwith bands in pole installations and with screws in wall installations. The hook is delivered without screws.
Anchoring clamp
Product property
They are characterized by high mechanical stability, reduced dimensions for easier handing,high mechanical and climatic resistance. Cable gripping device in insulating material ensures the double insulation of the neutral core and avoids damage to sheath, secured parts, no tools required. Stainless steel bail with two marbles compressed on the end, the conception allows an easier locking on the body of the clamp. They are in accordance with NFC 33-041.
| Type | Cross-section(mm²) |
| PAM-06 | 16-20 |
| PAM-07 | 16-25 |
| PAM-08 | 16-25 |
| PAL1400 | 35-70 |
| PAL1500 | 35-70 |
| PAL2000 | 70-120 |
| JBG-1 | 50-70 |
LV ABC Aerial Electrical Fittings
Anchoring clamp
2.1
LV ABC Aerial Electrical Fittings
Anchoring clamp
Product property
The plastic anchoring clamp is suitable for insulated low-voltage ABC cable. It is also suitable for multiple conductors. Easy installation and perfect insulated function. It is in accordance with NFC 33-042.
Material: Nylon plus fibre glass
| Type | Cross-section(mm²) |
| STA | 2×(16-35) |
| STB | 2×(16-25) |
| STC | 4×(16-25) |
| STD | 1×(16-70) |
| LA1 | 4×(16-25) |
| LA2 | 2×(6-16) |
| DCR-1 | 1×(4-25) |
| DCR-2 | 1×(4-25) |
| 2.1 | 1×(16-25) |
| PA1500 | 1×(50-70) |
| PA2000 | 1×(70-120) |
LV ABC Aerial Electrical Fittings
Anchoring clamp
LV ABC Aerial Electrical Fittings
Anchoring clamp
Product property
It is used to terminate 4-core of aerial bundle conductor. Its function is fixing and tightening the insulation conductor.
| Type | Cross-section(mm²) |
| NES-B0 | 4X(25-125) |
| NES-B1 | 4X(25-35) |
| NES-B2 | 4X(35-50) |
| NES-B3 | 4X(50-70) |
| NES-B4 | 4X(70-95) |
LV ABC Aerial Electrical Fittings
NEJ Wedge strain clamps for insulation cable
Application
This series are mainly used in 20kV or less than 10kV distribution system to fix and tighten the aluminum insulating wires at the corner or the end of the insulators on the stilt.
| Type | Applicable conductor (mm²) | Inner clamping range | Grip strength (kN) | Failure load (kN) | ||
| 1kv | 10kv | 20kv | ||||
| NEJ-1 | 35 | - | - | Φ10-Φ11 | 3.4 | 12.4 |
| 50 | 16 | - | Φ12-Φ13 | 4.6 | ||
| 70 | 25 | - | Φ14-Φ15 | 6.7 | ||
| 95 | 35 | - | Φ15-Φ17 | 8.9 | ||
| NEJ-2 | 120 | 50-70 | 25-35 | Φ16-Φ18.5 | 11.3 | 20.8 |
| 150 | 95 | 50 | Φ19-Φ21 | 13.7 | ||
| NEJ-3 | 185 | 120 | 70 | Φ21-Φ23 | 17.3 | 32.0 |
| NEJ-4 | 240 | 150 | 95 | Φ23-Φ25.6 | 22.5 | 41.7 |
| - | 185 | 120 | Φ24-Φ26 | 22.5 | ||
| - | 240 | 150 | Φ26-Φ27.5 | 22.5 | ||
| - | - | 185-240 | Φ27.5-Φ31.5 | 22.5 | ||
| NEJ-5 | - | 300 | 一 | Φ27.5-Φ31.5 | 28.2 | 52.1 |
LV ABC Aerial Electrical Fittings
JNS Four(two)-core bunched cable strain clamp series
Application
JNS series four-core bunched cable strain clamp series are fully used for fixing or tightening 1kV and less than 1kV overhead four(two)-cores bunched cable at ends of circuit
Function and Features
●It adopts four(two)-core parallel groove parallel gap structure, Put the four insulation cables into clamp according to circuit design without peeling off the coat, then tighten the bolt to bunch it.
●For inner block and filling pole with high strength, anti-climate resistance insulation plastic, it can be used for a long term;
Adopting wedge type self-tighten structure, after tightening the ring, it will be fixing, and get a quite big grasp strength.
Technical Data
| Type | Applicablevoltage (kV) | Applicableconductor(mm²) | Dimension (mm) | Note | ||
| A | B | C | ||||
| JNS-1A-1 | 1KV | 4×10-4×16 | 200 | 78 | 45 | Four cores |
| JNS-1A-2 | 4×16-4×50 | 260 | 100 | 62 | ||
| JNS-2A | 4×50-4×120 | 330 | 105 | 72 | ||
| JNS-1C | 2×10-2×16 | 200 | 78 | 30 | Two cores | |
| JNS-2C | 2×16-2×50 | 260 | 100 | 40 | ||
LV ABC Aerial Electrical Fittings
Suspension clamp
Product property
On poles, in alignment or angle, different level, also provide for hanging a public light bundle.
LV ABC Aerial Electrical Fittings
Suspension clamp
| Type | Condcutor range(mm²) | |
| LR94 | 16-95 | |
| LR95 | 16-95 | |
| 1.1A | 16-95 | |
| 1.1B | 16-95 | |
| 1.1C | 2×(25-35) 4×(16-120) | |
| 1.1D | 16-95 | |
| ES54-14 | 16-95 | |
| PS1500 | 16-95 | |
| SHC-1 | 4×(10-25) | |
| SHC-2 | 2×(25-35) | |
| SHC-3 | 4×(25-35) | |
| SHC-4 | 4×(35-50) | |
| SHC-5 | 4×(50-95) | |
SDPS25
LV ABC Aerial Electrical Fittings
Fixing Nail
| Type | Condcutor range(mm²) |
| LRZD-1 | 15-47 |
| LRZD-2 | 12-47 |
| LRZD-3 | 15-47 |
| LRZD-4 | 15-30 |
LV ABC Aerial Electrical Fittings
Type 304 Stainless Steel Band
Function and Features
●Band and buckle can be quickly formed to suit virtually any diameter.
●Applications include hose clamps, pipes, signs, cables, especially where superior strength is required.
●Dispensers-Handy plastic dispensers available with certre tum facility and pocket for buckles.
●Excellent corrosion resistance.
| Type | Width | Thickness | Weight | |||
| Inch | mm | Inch | mm | Lbs | kg | |
| LRB1450 | 1/4 | 6.35 | 0.02 | 0.5 | 1.76 | 0.8 |
| LRB3850 | 3/8 | 9.53 | 0.02 | 0.5 | 2.64 | 1.2 |
| LRB1276 | 1/2 | 12.70 | 0.03 | 0.76 | 5.5 | 2.5 |
| LRB5876 | 5/8 | 15.88 | 0.03 | 0.76 | 7.04 | 3.2 |
| LRB3476 | 3/4 | 19.05 | 0.03 | 0.76 | 8.27 | 3.76 |
| Type | Width | Thickness | Weight | |||
| Inch | mm | Inch | mm | Lbs | kg | |
| LRBD3850 | 3/8 | 9.53 | 0.02 | 0.5 | 3.08 | 1.4 |
| LRBD1276 | 1/2 | 12.70 | 0.03 | 0.76 | 5.94 | 2.7 |
| LRBD5876 | 5/8 | 15.88 | 0.03 | 0.76 | 7.48 | 3.4 |
| LRBD3476 | 3/4 | 19.05 | 0.03 | 0.76 | 8.71 | 3.96 |
LV ABC Aerial Electrical Fittings
Type 304 Stainless Steel Band
Stainless Steel Buckle
| Type | For band width | Thickness | |
| Inch | mm | mm | |
| LRBT14 | 1/4 | 6.35 | 0.8 |
| LRBT38 | 3/8 | 9.53 | 1.0 |
| LRBT12 | 1/2 | 12.70 | 1.2 |
| LRBT58 | 5/8 | 15.88 | 1.2 |
| LRBT34 | 3/4 | 19.05 | 1.5 |
| LRBT1 | 1 | 25.4 | 1.8 |
| LRBT114 | 1 1/4 | 32.5 | 2.0 |
| LRBL14 | 1/4 | 6.35 | 0.6 |
| LRBL38 | 3/8 | 9.53 | 0.7 |
| LRBL12 | 1/2 | 12.70 | 0.7 |
| LRBL58 | 5/8 | 15.88 | 0.8 |
| LRBL34 | 3/4 | 19.05 | 1.0 |
| Type | For band width | Thickness | |
| Inch | mm | mm | |
| LRBL14 | 1/4 | 6.35 | 0.6 |
| LRBL38 | 3/8 | 9.53 | 0.7 |
| LRBL12 | 1/2 | 12.70 | 0.7 |
| LRBL58 | 5/8 | 15.88 | 0.8 |
| LRBL34 | 3/4 | 19.05 | 1.0 |
| Type | For band width | Thickness | |
| Inch | mm | mm | |
| LRBL14 | 1/4 | 6.35 | 0.6 |
| LRBL38 | 3/8 | 9.53 | 0.7 |
| LRBL12 | 1/2 | 12.70 | 0.7 |
| LRBL58 | 5/8 | 15.88 | 0.8 |
| LRBL34 | 3/4 | 19.05 | 1.0 |
LV ABC Aerial Electrical Fittings
Application Tools
| Type | Description | Weight |
| LRBT001 | Band clamp tool for use with bands up to 3/4"(19.05mm) wide | 2.0kg |
| LRBT002 | Ratchet tension tool for use with bands up to 3/4"(19.05mm) wide, and also for all coated bands. | 1.8kg |
| LRBT003 | Heavy duty tool | 2.3kg |
| LRBT004 | Another type for ratchet tensioner for sue with bands up to 3/4"(19.05mm) wide and also for all coated bands. | 1.8kg |
| LRBT005 | It can be used with one hand. For using with bands up to3/4"(19.05mm) wide. | 1.5kg |
LV ABC Aerial Electrical Fittings
Ftth optical cable clamp
Anchor clamp class
Made of stainless steel 201/304
LV ABC Aerial Electrical Fittings
Ftth optical cable clamp
Anchor clamp class
Made of stainless steel 201/304
Installation mode
LV ABC Aerial Electrical Fittings
Ftth optical cable clamp
Anchor clamp class
Made of stainless steel 201/304
Installation mode
Hex Bolts
Application
The Hex bolts, concrete cavity depth and no higher cleanliness requirements, easy to install and inexpensive. Jacking by selecting the appropriate thickness of the buried depth, with the increase of buried depth, tension increased after the products are reliable and expandable functionality. Body material: stainless steel, carbon steel and other metal materials. Also known as through bolts, expansion bolts and expansion anchors, which is designed for consistent performance in concrete.
Widely used in securing the through objects'fastening, such as equipment,channel steel, guide rail, holder, steel structure, escalator, handrail and curtain wall etc. Every wedge anchor can be suitable for the standard anchorage depth, and also fit for shallow mining depth, to provide supreme flexibility for installation. Moreover the long thread offering the spacing installaiton, and can be flexibly adjustable to easy the installation.
ASTM A307and Hot Dip Galvanized ASTM153. Bolts are Coarse Threaded to a class 2 Fit. Hex Nuts and washers used on these bolts should be ordered separately.
| Dia | Length(mm) |
| M12 | 50 |
| M16 | 35 |
| M16 | 100 |
| M16 | 120 |
| M16 | 300 |
| M20 | 50 |
| M20 | 100 |
| M20 | 250 |
| M20 | 300 |
| M20 | 350 |
"A"Cable Suspension Bolts
Application
"A" cable suspension bolts are supplied with two square nuts. One nut is used to fasten the square head bolt to the pole and the other nut is used to secure a straight or angle cable suspension clamp to the bolt.
Material
Steel hot dip galvanized
| Catalognumber | BoltLength (in) | ThreadLength (in) | Weight/100 (lbs) |
| LR6645.A01 | 8 | 4 | 85 |
| LR6645.A02 | 10 | 6 | 104 |
| LR6645.A03 | 12 | 6 | 120 |
| LR6645.A04 | 14 | 6 | 138 |
| LR6645.A05 | 16 | 6 | 153 |
| LR6645.A06 | 18 | 6 | 168 |
| LR6645.A07 | 20 | 6 | 183 |
| LR6645.A08 | 22 | 6 | 198 |
| LR6645.A09 | 24 | 6 | 214 |
Brace bolts
Application
Brace bolts are used in place of carriage bolts or machine bolts to fasten braces to crossarms. The integral washer/hex head construction provides a static-proof design.
Material
Steel hot dip galvanized
| Catalognumber | Size(in) | ThreadLength (in) | Weight/100 (lbs) |
| LR8624-1/2 | 3/8 × 4 1/2 | 2 | 21 |
| Catalognumber | BoltLength (in) | ThreadLength (in) | Weight/100 (lbs) |
| LR6645.A10 | 10 | 6 | 165 |
| LR6645.A11 | 12 | 6 | 187 |
| LR6645.A12 | 14 | 6 | 204 |
| LR6645.A13 | 16 | 6 | 220 |
| LR6645.A14 | 18 | 6 | 220 |
Carriage Bolts
Application
MPS carriage bolts are roll threaded with square shoulder and square nut.
Material
Steel hot dip galvanized
| Catalognumber | BoltLength (in) | ThreadLength (in) | Weight/100 (lbs) |
| LR8634 | 4 | 3 | 16 |
| LR8634-1/2 | 4 1/2 | 3 | 16 |
| LR8635 | 5 | 3 | 18 |
| LR8636 | 6 | 3 | 22 |
| LR8637 | 7 | 4 | 24 |
| LR8638 | 8 | 4 | 26 |
| LR8640 | 10 | 4 | 34 |
| Catalognumber | BoltLength (in) | ThreadLength (in) | Weight/100 (lbs) |
| LR8645 | 5 | 3 | 35 |
| LR8646 | 6 | 3 | 41 |
| LR8647 | 7 | 4 | 44 |
| Lr8648 | 8 | 4 | 51 |
Clevis bolts
Application
Clevis bolts are used to provide dead end connections to eyes or links. Clevis end includes 1/2” diameter machine bolt with nut and a stainless steel self locking cotter pin to provide a secure vibration proof assembly.
Material
Steel hot dip galvanized
| Catalognumber | Size (in)(A×L) | ThreadLength (in) | Weight/100 (lbs) |
| LR7810 | 5/8×10 | 4 | 172 |
| LR7812 | 5/8×12 | 4 | 192 |
| Lr7814 | 5/8×14 | 4 | 208 |