Pole-mounted Air Breaker Switch
Pole mounted air breaker switch without fuse
| Type | L | W | H |
| (H)GW-12(15) | 1530 | 675 | 730 |
| (H)GW-24(27) | 1730 | 750 | 860 |
| (H)GW-30(36) | 1885 | 820 | 990 |
| Type | L | W | H |
| (H)RGW-12(15) | 1530 | 675 | 1510 |
| (H)RW-24(27) | 1730 | 750 | 1510 |
| (H)RGW-30(36) | 1885 | 820 | 1510 |
Pole-mounted Load Breaker Switch
General
LBS type Outdoor on load break switch (switch disconnector ) contained in this list are destined to switch stub lines and ring main lines or transformers(It can be equipped with MV HRG fuse links as short circuit protection function) or for switching under on load conditions.
LBS type switch comply with IEC/IEEE and DVE-recommendation standards. Especially comply with DIN VDE 0670 part 3 and IEC publication IEC-60265,IEC-129.
Service Environment
●Airtemperature: Maximum temperature: +75℃; Minimum temperature:-45℃
●Humidity: Monthly average humidity 95%; Daily average humidity 90%.
●Altitude above sea level: Maximum installation altitude: 2500m.
●Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
●No frequent violent shake.
Features and Benefits
●Compact design
●All steel parts either in stainless steel or hot-dip galvanized
●Solid and stable base frame
●Main contact with icing protection
●Insulators available in porcelain or alternatively in silico ne
●Minimal sag for the line-connection thanks to the two fixed terminals
●Completely maintenance antirust AL alloy -Arc chamber
●Switching-off procedure without external arc
●Short circuit makingcapacity under specific conditions possible
●Fixing on the supporting structure either by clamping (free setting) or screwing (holes in the base frame)
●Easy on-site installation and setting
●High reliability: up to 1 '000 cycles (depending on the making current)
Technical characteristics
Sheet 1
| Item | Unít | Data | |||
| Rated voltage | kV | 12 | 24 | 36 | |
| Rated frequency | Hz | 50/60 | |||
| Ratedcurrent | A | 200/400/630 | |||
| Rated short circuit withstand current(IS) | KA | 20 | |||
| Rated peak withstand current(IS) | KA | 50 | |||
| Rated making current | KA | 31.5-50 | |||
| Rated insulation leve(HV) | Lightning impulse | KA | 75/85 | 125/145 | 170/195 |
| Power frequency withstand | 45 | 55/75 | 75/100 | ||
| Rated short circuit breaking capacity cos. Φ(0.7)Without maintenance of contacts | |||||
Pole-mounted Load Breaker Switch
| ltem Data | ||||||||
| For active circuits | 20breakings | 630 | 630 | 400 | ||||
| 30breakings | 400 | 400 | 300 | |||||
| 40breakings | 300 | 300 | 250 | |||||
| 50breakings | A | 250 | 250 | 170 | ||||
| 75breakings | 170 | 170 | 160 | |||||
| 120breakings | 110 | 110 | 110 | |||||
| 200breakings | 65 | 65 | 65 | |||||
| 280breakings | 50 | 50 | 50 | |||||
| For ring circuits | A | 630 | 400 | 250 | ||||
| Rated breaking capacity of transformerRated breaking capacity of cable chargingRated breaking capacity of earthing fault | A | 501156 | ||||||
| A | ||||||||
| A | ||||||||
The DIN type fuse is held in spring type contacts, secured by a tail lever. All the components are made of stainless steel, to preventcorrosion, have Jong live, and in the reset position. The trip lever is parked in an over-centre position.
| Type | C | D | F | H | L | W |
| LBS-12 | 800 | 1080 | 1200 | 670 | 775 | 1100 |
| LBS-24 | 900 | 1180 | 1200 | 770 | 450 | 1400 |
| LBS-36 | 1000 | 1280 | 1200 | 870 | 700 | 1900 |
Pole-mounted IACM Volley Disconnector
| Item | Unit | Data | ||
| Rated voltage | kV | 12 | 24 | 36 |
| Rated frequency | Hz | 50/60 | ||
| Rated current | A | 100/200/400 | ||
| Rated short-circuit withstand/breaking current | KA | 12.5 | ||
| Rated short-circuit makingcurrent (peak) | KA | 32 | ||
| Rated peak withstand current | kA | 32 | ||
| Rated short-circuit time | Sec | 1 | ||
| Mechanical Operations | Times | 5000 | ||
| Power frequency withstandvoltage (1 min) | kV | 28/32 | 50/60 | 70/80 |
| Lightning impulse withstandvoltage (peak) | kV | 76/85 | 125/145 | 170/195 |
Pole-mounted SF6 Load Breaker Switch
General
The LRFWseries outdoor SF6 load switch is a three-phase AC 50Hz /60Hz outdoor medium-voltageswitchgear, which can break off and close the load current and overload current in the power system; The load switch is equipped with intelligent controller to realize the automation of distribution system.
Application voltage levels include: 12kV, 24kV and 36kV. Application standard: IEC62271-200
Product structure
1.Lift handle
2.Carrying handle
3.Integrative rubber bushing
4.Manual operation handle
5.Contact position indicator
6.Load switch support frame
7.Grounding device
8.Open closed locking device for load switch
9.Highgas pressure relief explosion-proof device
10.Electric mechanism device
11.SF6 Gas pressure gauge
12.SF6 Gas filling valve
Model Designation
| ① | Manufacturers(LR -L&R GROUP) |
| ② | Product name (FW -outdoor SF6 LBS) |
| ③ | Rated Voltage ( kV) |
| ④ | Rated continuous Current (A) |
Pole-mounted SF6 Load Breaker Switch
Service and Installation Conditions
●Height above sea level:≤3000m
●Air temperature:-40℃\~+50℃
●Maximum diurnal temperature difference: ≤25°C
●Relative humidity: Daily mean 95% monthly average 90%
●Maximum wind speed: ≤34m/ s
●Earthquake intensity: < 8 degree
●Icing thickness: < 10mm
●Thickness of snow: < 35mm
●Irradiance:< 0.1W/cm2
●Pollution grade:class、IVclass
Installation site: No fire disaster, explosion danger, chemical corrosion and frequent strenuous vibration places
Technical characteristics
| Item | Unit | Data | ||
| Rated voltage | kV | 12 | 24 | 36 |
| Rated frequency | Hz | 50/60 | ||
| Rated current | A | 400/630 | ||
| Rated short-circuit withstand/breaking current | KA | 12.5 | ||
| Rated short-circuit making current (peak) | KA | 31.5 | ||
| Rated peak withstand current | kA | 31.5 | ||
| Rated short-circuit time | Sec | 1 | ||
| Power Operating Time (Close/Open) | Sec | <2 | ||
| Mechanical Operations | Times | 5000 | ||
| Rated full load operations | Times | 400 | ||
| Power frequency withstand voltage (1 min) | kV | 28/32 | 50/60 | 70/80 |
| Lightning impulse withstand voltage (peak) | kV | 76/85 | 125/145 | 170/190 |
| IP Level | 65 | |||
| Arc Extinction Medium | Times | SF6 Gas | ||
| Insulation Medium | SF6 Gas | |||
| SF6 gas year leak rate | ≤0.5% | |||
Remote Terminal Unit (RUT)
General
The Remote terminal unit including SCADA Facility.
F2X14-DK Series IPModem is a kind of cellular terminal device that provides data transfer function by GPRS/WCDMA/EVDO/LTE network.
It adopts high-powered industrial 32 bits CPU and embedded real time operating system, it is dual serial port design, supports RS232 or RS485 port (Optional) that can conveniently and transparently connect one device to a cellular network, allowing you to connect to your existing serial devices with only basic configuration. It also has low power consumption states.
It has been widely used on M2M fields, such as intelligent substation, intelligent distribution network, smart electricity meters, intelligent interactive terminal, intelligent scheduling, intelligent home appliances, intelligent electricity building, power grids for smart cities, intelligent power generation system, smart grids (Such as new energy storage systems)and so on.
Technical characteristics
| Item | Unit | Data |
| Battery voltage | V | DC12 |
| Battery capacity | Ah | 38 |
| Mechanical endurance | C/O | 5,000 |
| Protection indices | IP35 | |
| Protection against short-circuits | YES | |
| LV protection against overvoltage | YES |
Pole-mounted SF6 Load Breaker Switch
Dimensional drawing of 12kV SF6 load switch
Dimensional drawing of 36kV SF6 load switch
Pole-mounted SF6 Load Breaker Switch
Single pole installation
Pole-mounted Vacuum Circuit Breaker
General
Zw32 Series outdoor high voltage vacuum circuit breaker is used in three phases power system of AC 50HZ,voltage 12-36KV toswitch on/off loading current,it has function of protecting overloading and short circuit meeting the requirement of control and measurement realizing remote control and monitor and so on,it applies to protect and control distribution,industrial enterprises and frequent switching in rural network.
Application voltage levels include: 12kV, 24kV and 36kV.
Application standard:IEC62271-200
Service and Installation Conditions
●Height above sea level: ≤3000m
●Air temperature:-40℃\~+50℃
●Maximum diurnal temperature difference: ≤25°C
●Relative humidity: Daily mean 95% Monthly average 90%
●Maximum wind speed:≤34m/ s
●Earthquake intensity: < 8 degree
●Icing thickness: < 10mm
●Thickness of snow: < 35mm
●Irradiance: < 0.1W/cm2
●Pollutiongrade:class、IVclass
●Installation site: No fire disaster, explosion danger, chemical corrosion and frequent strenuous vibration places
Product structure
Model Designation
| ① | Vacuum |
| ② | Outdoor type |
| ③ | Design number |
| ④ | Rated voltage (KV) |
| ⑤ | With switch disconnectors |
| ⑥ | Rated Current (A) |
| ⑦ | Rated short-circuit breaking current ( KA) |
Pole-mounted Vacuum Circuit Breaker
| Item | Unit | ||||
| Data | |||||
| Rated voltage | kV | 12 | 24 | 36 | |
| Rated frequency | Hz | 50/60 | |||
| Rated current | A | 400/630 | |||
| Rated short-circuit withstand/breaking current | KA | 12.5/20 | |||
| Rated short-circuit making current (peak) | kA | 31.5/50 | |||
| Rated peak withstand current | KA | 31.5/50 | |||
| Duration of rated short circuit current | Sec | 4 | |||
| Rated operating sequence | (O)-0.3s-(CO)-180s-(CO) | ||||
| Mechanical Operations | Times | 10000 | |||
| Rated full load operations | Times | 400 | |||
| Power frequency withstand voltage (1 min) | kV | 28/32 | 50/60 | 70/80 | |
| Lightning impulse withstand voltage (peak) | kV | 76/85 | 125/145 | 170/190 | |
| Closing time | ms | 25-50 | |||
| Full breaking time | ms | ≤100 | |||
| Arcing time | ms | ≤20 | |||
| Mechanical endurance | Time | 10000 | |||
| Rated Input power of charging motor | w | 40 | |||
| Rated operating voltage and rated voltage of auxiliary circuit | V | DC200、110、24 | |||
| DC220、110、24 | |||||
| Charging time at rated voltage | S | ≤10 | |||
| Over-current release | Rated current | A | 50 | ||
| Accuracy of tripping current | % | ± 10 | |||
| Mechanical endurance | time | 10000 | |||
Pole-mounted Vacuum Circuit Breaker
Pole installation
Pole-mounted 3 Phase Vacuum Auto Recloser
General
LR32 series pole mounted vacuum recloser is a three-phase AC 50Hz /60Hz outdoor medium-voltage switchgear. It is used in overhead power distribution lines or distribution substations. It is used to divide and combine load current, overload current and short-circuit current. Products Set protection, measurement, signal, control and other functions in one, with 0 to 3 times adjustable automatic reclosing function.
Application voltage levels include: 12kV, 18kV, 24kVand 36kV. Products meet IEC62271-111: 2012 andother relevant international standards.
●This product consists of a vacuum circuit breaker ona column, a DLXCLS51power distribution terminal, and a power voltage transformer. The modules are connected via outdoor control cables and hermetically sealed aviation plugs.The whole machine has a modular design and is easy to install and maintain.
●The product adopts high-quality stainless steel housing, which does not rust for long-term outdoor operation. The reliable three-phase monostable permanent magnet mechanism has a mechanical life of 10,000 times.
●Reliable protection logic and innovative automation design scheme, friendly man-machine interface, advanced communication mode, and multiple communication protocols are available
Product structure
LR32 series vacuum circuit breaker on the pole is composed of three-phase insulated pole, vacuum arc extinguishing chamber, three-phase permanent magnet operating mechanism, manual opening handle and housing.
●The three-phase insulatedpole is casted by outdoor epoxy resin, which can effectively prevent UV and aging. The builtin vacuum arc extinguishing chamber of the insulated pole adopts the current transformer and voltage sensor, and the transformation ratio can be selected according to the user's needs.
●LR32 series pole mounted vacuum reclosers are designed for miniaturization. A t three-phase insulated pole is vertically installed on the upper end surface of the shell. A monostable permanent magnet mechanism is assembled for each pole inside the shell, and a manual opening device is also provided.
●The intelligent terminal is connected to the vacuum circuit breaker through a control cable, and is used to drive the permanent magnet mechanism for opening and closing operations.
●The power of the recloser unit is divided into main and backup power supply.The main power supply is AC 220/110V, which is obtained by the power voltage transformer (PT); the backup power is provided by the battery (installed in the intelligent control unit box). The main power source charges the backup power source during normal work; when the main power source is lost, it is powered by the backup power source, which can support more than 300 closing operations or 48 hours of equipment operation.
1.Opening and closing handle
2.Opening and closing handle
3.Housing
4.Aviation socket
5.Voltage sensor (two groups)
6.Solid-sealed pole
7.Current transformer
8.Lower outlet
9.Upper outlet base
10.Lifting ring
Pole-mounted 3 Phase Vacuum Auto Recloser
| Item | Unit | Data | |||
| Rated voltage | kV | 12 | 18 | 24 | 36 |
| Rated frequency | Hz | 50/60 | |||
| Rated current | A | 400/630/800 | |||
| Rated short-circuit withstand/breaking current | KA | 12.5/ 16 | |||
| Rated short-circuit making current (peak) | KA | 31.5/40 | |||
| Rated peak withstand current | KA | 31.5/40 | |||
| Rated short-circuit time | S | 3 | |||
| Capacity of rated short-circuit current breaking | Times | 30 | |||
| Power frequency withstand voltage (1 min) | kV | 28/32 | 38/45 | 50/60 | 70/80 |
| Lightning impulse withstand voltage (peak) | kV | 76/85 | 95/110 | 125/145 | 170/190 |
| Rated operating sequence | O-0.2s-CO-2s-CO-5s-CO | ||||
| Mechanical endurance | Times | 10,000 | |||
Pole-mounted 3 Phase Vacuum Auto Recloser
Dimensional drawing of 12/18kV Auto Recloser
Dimensional drawing of 24/36kV Auto Recloser
Pole-mounted 3 Phase Vacuum Auto Recloser
Dimensional drawing of 12/18kV Auto Recloser with voltage transformer
Dimensional drawing of 24/36kV Auto Recloser with voltage transformer
Pole-mounted 3 Phase Vacuum Auto Recloser
Single pole installation
Double pole installation
| ZW7- 36 |
ZW7-36 Series Outdoor HV Vacuum Circuit Breaker
Overview
ZW7-36 series Outdoor High-volt Vacuum Circuit Breaker, a three-phase AC 50Hz outdoor high volt switchgear, is applicable for the36 KV power distribution and transmission system to close or open the load current, over-load current, short-circuit current and so on.
Model Designation
| ① | Vacuum circuit breaker |
| ② | Outdoor type |
| ③ | Segnence |
| ④ | Rated voltage |
Service and Installation Conditions
●Ambient temperature: from -30 to 40 (from-40 to +40 for the particular order).
●Height above sea level: ≤1000m(Value over 1000m should be indicated in advance.)
●Air humidity: relative humidity: ≤ 95% daily at average
≤ 90% monthly at average
●Wind pressure: ≤700Mpa.
●Sunshine intensity:0.1 W/cm under the 0/5m/s wind velocity
Main Parameters
●Maximum temperature difference daily allowed: 25
●Earthquake intensity: ≤ 8 degree
| ltem | Unit | Specification | |
| Rated voltage | kV | 36 | |
| Rated insulating | Lightning impulse withstand voltage (1.2/50 μ s) | kV | 215/200 |
| level | Power frequency withstand voltage (1min) | kV | 118/95 |
| Rated current | A | 1600 /2000 | |
| Rated short circuit withstand/breaking current | KA | 20/25/31.5 | |
| Rated operating sequence | O-0.3s-CO-180s-CO | ||
| Breaking times of the rated short circuit withstand/breaking current | Times | 20 | |
| Rated short-circuit making current | KA | 50/60/80 | |
| Rated short circuit switching current | kA | 50/60/80 | |
| Mechanical life | Times | 10000 | |
| Rated voltage of auxiliary circuit | DC220/110 | ||
| Rated operating voltage | AC220 | ||
| Open distance of the contact | mm | 22±2 | |
| Super travel of the contact | mm | 4±1 | |
| Average opening speed | m/s | 1.4~1.8 | |
| Average closing speed | m/s | 0.4~0.9 | |
| Bounce time of the closing of the contact | m/s | 3 | |
| Synchronism of the opening of the three phases | ms | 2 | |
| Closing time | ms | 75(spring mechanism) | |
| Opening time | ms | 60 | |
① ② ③ ④
LW8-36 Series Outdoor HV SF6 Circuit Breaker
Overview
LW8-35 outdoor high-volt AC SF6 circuit breaker is applicable for outdoor 50Hz three-phase HV electric equipment and control & protection of 36kV power distribution & transmission system, as well as measurement and protection via the breaker enclosed current transformer. Breaker is also used for interconnected circuit breakers andswitchingcapacitor banks.
Model Designation
| ① | SF6 circuit breaker |
| ② | Outdoor type |
| ③ | Design sequence |
| ④ | Rated voltage |
Service and Installation Conditions
●Ambient temperature: -30℃\~+40℃(special order-40℃\~+40℃)
●Elevation: ≤1000m (Value over 1000m should be indicated in advance.)
●Humidity: Daily average≤95%; Monthly average≤90% (25℃)
●Wind speed: ≤35m/s
●Creepage distance: 25mm/kV or 31mm/kV
Main Parameters
| Item | Unit | Specification | |
| Rated voltage | kV | 36 | |
| Rated insulatinglevel | Lightning impulse withstand voltage (1.2/50μ s) | kV | 215/200 |
| Power frequency withstand voltage (1min) | kV | 118/95 | |
| Rated current | A | 1600/2000/2500/3150 | |
| Rated short circuit withstand/breaking current | KA | 20/25/31.5 | |
| Rated SF6 pressure (20℃ REL.) | MPa | 0.40 /0.50 | |
| Lockout pressure (20℃ REL.) | MPa | 0.30 /0.40 | |
| Rated short circuit withstand/breaking current | kA | 20/25/31.5 | |
| Rated short-circuit making current | KA | 50/60/80 | |
| Rated short circuit switching current | KA | 50/60/80 | |
| Rated out-of-phase breaking current | KA | 5/6.3/8 | |
| Breaking times of the rated short circuit withstand/breaking current | Times | 20 | |
| Mechanical life | Times | 10000 | |
| Closing time (under rated operation voltage) | s | ≤0.1 | |
| Opening time (under rated operation voltage) | S | ≤0.06 | |
| Rated operating sequence | O-0.3s-CO-180s-CO | ||
| Rated switching single capacitor bank current | A | 400 | |
| Rated short-circuit duration | S | 4 | |
| Annual leakage | %Year | ≤0.3 | |
| Moisture content of SF6 (20℃) | uL/L | ≤150 | |
| Voltage of opening and closing coil | V | AC:220/380 DC:48/110/220 | |
| Voltage of charging motor | V | ||
LW36-72.5 Series Outdoor HV SF6 Circuit Breaker
Overview
LW36-72.5/3150-40SF6high-voltage AC circuit breaker is of 3-phase 50Hz high-voltage switchgear, used for the control and protection of 72.5kV power distribution and transmission system, as well as the network interconnected circuit breakers and the switching of capacitor banks.The breaker conforms to IEC56 and GB1984-2003 about high-voltage alternating current circuit breakers.
Service and Installation Conditions
●Ambient temperature:-30℃\~+40℃(special order-40℃\~+40℃)
●Elevation: ≤1000m (Value over 1000m should be indicated in advance.)
●Humidity:Daily average≤95%; Monthly average≤90% (25℃)
●Wind speed: ≤35m/s
●Creepage distance: 25mm/kV or 31mm/kV
Model Designation
| L W 36-72.5/T 3150 40 ① ② ③ ④ | V 中 ⑤ ⑥ ⑦ |
| ① | SF6 circuit breaker |
| ② | Outdoor |
| ③ | Design sequence |
| ④ | Rated voltage |
| ⑤ | Spring mechanism |
| ⑥ | Rated current |
| ⑦ | Rated short-circuit breaking current |
LW36-72.5 Series Outdoor HV SF6 Circuit Breaker
| Item | Unit | Specification | |
| Rated voltage | kV | 126/145 | |
| Rated insulating | Lightning impulse withstand voltage (1.2/50μs) | kV | 650/550 |
| level | Power frequency withstand voltage (1min) | kV | 300/230 |
| Rated current | A | 2500/3150/4000 | |
| Rated short circuit withstand/breaking current | kA | 31.5 /40/50 | |
| Rated short-circuit making current | kA | 80/1000/ 125 | |
| Rated short circuit switching current | KA | 80/1000/125 | |
| Rated out-of-phase breaking current | KA | 8 /10/ 12.5 | |
| Rated SF6 pressure (20°C REL.) | MPa | 0.40 / 0.50 | |
| Lockout pressure (20C REL.) | MPa | 0.30 /0.40 | |
| Breaking times of the rated short circuit withstand/breaking current | Times | 20 | |
| Mechanical life | Times | 10000 | |
| Closing time (under rated operation voltage) | s | ≤0.1 | |
| Opening time (under rated operation voltage) | S | ≤0.06 | |
| Rated operating sequence | O-0.3s-CO-180s-CO | ||
| Rated switching single capacitor bank current | A | 400 | |
| Rated short-circuit duration | s | 4 | |
| Annual leakage | %Year | ≤0.3 | |
| Moisture content of SF6 (20℃) | uL/L | ≤150 | |
| Voltage of opening and closing coil | V | AC:220/380 DC:48/110/220 | |
| Voltage of charging motor | V | AC:220 DC:110/220 | |
LW36-126(145) Series Outdoor HV SF6 Circuit Breaker
Overview
LW36-126(145)/3150-40SF6 high-voltageAC circuit breaker is of 3-phase 50Hz high-voltage switchgear, used for the control and protection of 126kV/145kV powerdistribution and transmission system, as well as being used as the network interconnected circuit breaker and in the places switching capacitor bank
Service and Installation Conditions
●Ambient temperature:-30℃\~+40℃(special order-40℃\~+40℃)
●Elevation: ≤1000m (Value over 1000m should be indicated in advance.)
●Humidity: Daily average≤95%; Monthly average≤90% (25℃)
●Wind speed: ≤35m/s
●Creepagedistance: 25mm/kV or 31mm/kV
Model Designation
| ① | SF6 circuit breaker |
| ② | Outdoor |
| ③ | Design sequence |
| ④ | Rated voltage |
| ⑤ | Spring mechanism |
| ⑥ | Rated current |
| ⑦ | Rated short-circuit breaking current |
LW36-126(145) Series Outdoor HV SF6 Circuit Breaker
Main Parameters
| Item | Unit | Specification | |
| Rated voltage | kV | 72.5 | |
| Rated insulating | Lightning impulse withstand voltage (1.2/50μ s) | kV | 410/350 |
| level | Power frequency withstand voltage (1min) | kV | 200/160 |
| Rated current | A | 2000/2500/3150/4000 | |
| Rated short circuit withstand/breaking current | KA | 31.5 /40/50 | |
| Rated short-circuit making current | KA | 80/ 1000 /125 | |
| Rated short circuit switching current | KA | 80 / 1000 / 125 | |
| Rated out-of-phase breaking current | kA | 8 / 10/ 12.5 | |
| Rated SF6 pressure (20°C REL.) | MPa | 0.40 /0.50 | |
| Lockout pressure (20℃ REL.) | MPa | 0.30 /0.40 | |
| Breaking times of the rated short circuit withstand/breaking current | Times | 20 | |
| Mechanical life | Times | 10000 | |
| Closing time (under rated operation voltage) | s | ≤0.1 | |
| Opening time (under rated operation voltage) | s | ≤0.06 | |
| Rated operating sequence | O-0.3s-CO-180s-CO | ||
| Rated switching single capacitor bank current | A | 400 | |
| Rated short-circuit duration | s | 4 | |
| Annual leakage | %Year | ≤0.3 | |
| Moisture content of SF6 (20℃) | uL/L | ≤150 | |
| Voltage of opening and closing coil | V | AC:220/380 DC:48/110/220 | |
| Voltage of charging motor | V | AC:220 DC:110/220 | |
List of Disconnecting Switch Model Series
GW37-12\~252/630\~4000 Centre-break two post disconnector
GW38-40.5\~252/630\~4000 Double-break three post disconnector
●GW16-72.5-252/1250\~4000 Vertical knee-type disconnector
●GW17-72.5\~252/1250\~4000 Horizontal knee-type disconnector
●GW5-40.5\~126/630\~3150 V-type centre breaker disconnector
●GW8-40.5\~126/630 Neutral point disconnector
●GW13-40.5\~126/630\~1250 Neutral point disconneetor
●JW-40.5\~252/630 Earthing switch
●GW1-12\~40.5/200\~2000 Vertical break two post isolating switch
GW9-12/200\~1250 Vertical break two post isolating switch
Model Designation
| ① | Product type G--Isolate switch J--earthing switch |
| ② | Service conditions W--out door N--Indoor |
| ③ | Design No. |
| ④ | Rated voltage |
| ⑤ | Blank---without earth bladesD--with single earth bladesD2--with double earth blades |
| 6 | Isolate switch operating mechanism J-Motor S-Manual |
| ⑦ | Rated current |
| ⑧ | Rated schort time withstand current (eff) |
GW4 Series Centre-break Two Post Disconnector
| Item | Unit | |||||
| Specification | ||||||
| Rated Voltage | kV | 36 | 72.5 | 123 | 145 | |
| Rated Current | A | 630、1250、1600、2000、2500、3150 | ||||
| Rated short withstand current and time | kA/s | 25~50/ 4 | ||||
| Rated perk/marking withstand current | KA | 63~125 | ||||
| Lightning impulse withstand voltage(1.2/50μs) | To earth | kV | 200 | 325 | 500 | 650 |
| To phase | kV | 200 | 325 | 500 | 650 | |
| Acrou open DS | kV | 215 | 405 | 650 | 750 | |
| To earth | kV | 95 | 140 | 230 | 275 | |
| 1min power frequency withstand voltage | To phase | kV | 95 | 140 | 230 | 275 |
| Acrou open DS | kV | 118 | 180 | 300 | 315 | |
| Rated mechanical terminal load | Level of lateral load | N | 750 | 750 | 1500 | 1500 |
| Level of vertical load | N | 500 | 500 | 1000 | 1000 | |
| Vertical force | N | 750 | 750 | 1000 | 1000 | |
| Max.Manual operating moment | N.m | 200 | ||||
| Control voltage | V | AC 220、DC 110/220 | ||||
| Motor voltage | V | AC 220/380、DC 110/220 | ||||
GW5 Series V-type Centre Breaker Disconnector
| Item | Unit | |||||
| Specification | ||||||
| Rated Voltage | kV | 36 | 72.5 | 123 | 145 | |
| Rated Current | A | 630、1250、1600、2000、2500、3150 | ||||
| Rated short withstand current and time | KA/s | 25~50/ 4 | ||||
| Rated perk/marking withstand current | kA | 63~125 | ||||
| Lightning impulse withstand voltage(1.2/50μs) | To earth | kV | 200 | 325 | 500 | 650 |
| To phase | kV | 200 | 325 | 500 | 650 | |
| Acrou open DS | kV | 215 | 405 | 650 | 750 | |
| 1min power frequency withstand voltage | To earth | kV | 95 | 140 | 230 | 275 |
| To phase | kV | 95 | 140 | 230 | 275 | |
| Acrou open DS | kV | 118 | 180 | 300 | 315 | |
| Rated mechanical terminal load | Level of lateral load | N | 750 | 750 | 1500 | 1500 |
| Level of vertical load | N | 500 | 500 | 1000 | 1000 | |
| Vertical force | N | 750 | 750 | 1000 | 1000 | |
| Max.Manual operating moment | N.m | 200AC 220、DC 110/220AC 220/380、DC 110/220 | ||||
| Control voltage | V | |||||
| Motor voltage | V | |||||
GW38 Series Double-break Three Post Disconnector
| Item | Unit | |||||
| Specification | ||||||
| Rated Voltage | kV | 36 | 72.5 | 123 | 145 | |
| Rated Current | A | 630、1250、1600、2000、2500、3150 | ||||
| Rated short withstand current and time | kA/s | 25~50/4 | ||||
| Rated perk/marking withstand current | KA | 63~125 | ||||
| Lightning impulse withstand voltage(1.2/50μs) | To earth | kV | 200 | 325 | 500 | 650 |
| To phase | kV | 200 | 325 | 500 | 650 | |
| Acrou open DS | kV | 215 | 405 | 650 | 750 | |
| 1min power frequency withstand voltage | To earth | kV | 95 | 140 | 230 | 275 |
| To phase | kV | 95 | 140 | 230 | 275 | |
| Acrou open DS | kV | 118 | 180 | 300 | 315 | |
| Rated mechanical terminal load | Level of lateral load | N | 750 | 750 | 1500 | 1500 |
| Level of vertical load | N | 500 | 500 | 1000 | 1000 | |
| Vertical force | N | 750 | 750 | 1000 | 1000 | |
| Max.Manual operating moment | N.m | 200 | ||||
| Control voltage | V | AC 220、DC 110/220 | ||||
| Motor voltage | V | AC 220/380、DC 110/220 | ||||
JW Series Earthing Switch
| Item | Unit | Specification | ||||
| Rated Voltage | kV | 36 | 72.5 | 123 | 145 | |
| Rated Current | A | 630、1250、1600、2000、2500、3150 | ||||
| Rated short withstand current and time | kA/s | 25~50/4 | ||||
| Rated perk/marking withstand current | kA | 63~125 | ||||
| Lightning impulse withstand voltage(1.2/50μs) | To earth | kV | 200 | 325 | 500 | 650 |
| To phase | kV | 200 | 325 | 500 | 650 | |
| Acrou open DS | kV | 215 | 405 | 650 | 750 | |
| 1min power frequency withstand voltage | To earth | kV | 95 | 140 | 230 | 275 |
| To phase | kV | 95 | 140 | 230 | 275 | |
| Acrou open DS | kV | 118 | 180 | 300 | 315 | |
| Rated mechanical terminal load | Level of lateral load | N | 750 | 750 | 1500 | 1500 |
| Level of vertical load | N | 500 | 500 | 1000 | 1000 | |
| Vertical force | N | 750 | 750 | 1000 | 1000 | |
| Max.Manual operating moment | N.m | 200AC 220、DC 110/220AC 220/380、DC110/220 | ||||
| Control voltage | V | |||||
| Motor voltage | V | |||||
KYN61 High Voltage Metal-clad Movable Switchgear
Product Summary
KYN61 air insulated metal-clad movable switchgear is an indoor switchgear, assembly operating under the Conditions of 50/60Hz three phase and rated 20/40.5kV AC voltage, which applied to the transmission and distribution for generators, transformer substations and the industry and mine enterprises. It also can be used to control, protect and monitor electric circuits, and very useful to frequent operating conditions. It complies with IEC 62271,IEC 60943,IEC 60068,IEC 600816,ANSIC37.85 and other relative standards.
Environmental Conditions
●Ambient Temperature: No more than +40C and no less than -15C.Average
●temperature is no more than +35Cwithin 24 hours.
●Altitude: No more than 1000m.
●Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
●Earthquake Intensity: No more than 8 degrees.
●Vapor pressure: average daily value is no more than 2.2kPa, average monthly value is no more than 1.8kPa.
●Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Product Features
●The cabinets and partition board adopting hot-dip Al-Zn alloy-coated steel sheet and frame adopting assembled structure make high overall intensity and good earth continuity.
●The cabinet is combined type and the handcart of breaker is floor structure type.
●The new composite insulating vacuum circuit breaker has the characteristics of interchangeability and simple replacement.
●The handcart adopts screw propulsion mechanism, which moves the handcart easily and prevent mis- operation to damage the propulsion mechanism.
●All the operations could be done when the cabinet door is closed.
●The interlocking between the main switch, the handcart and the switch cabinet adopts the mandatory mechanism of mechanical locking,meeting the functions of five- preventions.
●The cable room is spacious and can be connected to a number of cables.
●The degrees of protection is IP4X, which effectively prevents the equipment from beinginvaded by sundries and insect pests.
●The product runs safely and reliably through the harsh condensation, filth and internal arc tolerance test.
KYN61 High Voltage Metal-clad Movable Switchgear
| Content | Unit | Value | ||
| Rated Voltage | kV | 24 | 36 | |
| Rated Current | A | 630/1250/1600/2000/2500 | ||
| Rated Frequency | Hz | 50/60 | ||
| Power Frequency Withstand Voltage in 1 min | Phase,Earthed | kV | 52 | 80 |
| Isolating Fracture | kV | 58 | 85 | |
| Lightning Impulse Withstand Voltage(Peak) | Phase,Earthed | kV | 110 | 170 |
| Isolating Fracture | kV | 120 | 180 | |
| Rated Current of the Main Busbar | A | 630/1250/1600/2000/2500 | ||
| Rated Current of the Branch Busbar | A | 630/1250/1600/2000/2500 | ||
| Rated Short-circuit Breaking Current | KA | 20/25/31.5 | ||
| Rated Short-time Withstand Current(4s) | KA | 20/25/31.5 | ||
| Rated Peak Withstand Current | KA | 50/63/80 | ||
| Rated Short Circuit Making Current | kA | 50/63/80 | ||
| Frequency Withstand Voltage in 1 min of Aux Control Loop | V | 2000 | ||
| Internal Arc Duration Test(0.5s) | kA | 31.5 | ||
| Degrees of Protection | IP | IP4X(IP2X when the front door is opened) | ||
| Rated Voltage of Aux Control Loop | V | AC or DC110/220 | ||
Main circuit scheme diagram
KYN28A High Voltage Metal-clad Movable Switchgear
Product Summary
KYN28A high voltage indoor metal-clad movable switchgear is a complete power distribution device for 12kV, 3 phase AC 50/60Hz, single bus sectionalized system. It is mainly used for power transmission of middle/small generators in power plants, power receiving. transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor etc., so as to control, protect and monitor thesystem. It complies with IEC 62271,IEC 60943,IEC 60068,IEC 600816,ANSI C37.85 andother relative standards. It has functions of preventing to push or pull the breaker's handcart with load, breaker' s mistakenly open or close, shut off the breaker when the grounding switch is on the position of close, enter into a electriferous compartment, mistakenly close the interlock function of the grounding switch when it is electriferous. It can be used with domestic VCA and VS1 vacuum circuit breaker, it can be used with VD4 from ABB and EV12Sfrom Schneider.
Environmental Conditions
●Ambient Temperature: No more than +40C and no less than -15C.Average temperature is no more than +35C within 24 hours.
●Altitude: No more than 1000m.
●Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
●Earthquake Intensity: No more than 8 degrees.
●Vapor pressure: average daily value is no more than 2.2kPa, average monthly value is no more than 1.8kPa.
●Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Product Features
●The cabinets and partition boards adopting hot-dip Al-Zn alloy-coated steel sheet and frame adopting multiple bending technology make high overall intensity and good earth continuity.
●Fully considering the operation characteristics of the neutral point of the power system without grounding or through the arc suppression coil
●Completely metal clad and absolutely compartments separation.
●The degrees of protection is IP4X, which effectively prevents the equipment from beinginvaded by sundries andinsect pests.
●Simple and effective mechanical block for five- preventions,preventing from mis- operating.
●The movable handcart use sworm and worm wheel propelling mechanism. The same type of handcart can be interchanged completely, easy to operate and maintain.
●It can be installed away from the wall, which is more convenient for double sides maintenance. Or it can be installed against the wall, maintain in front of the cabinet, with less space occupation.
●Min. width of panel is 550mm, which can increase the utilization of distribution room.
●The product runs safely and reliably through the harsh condensation, filth and internal arc tolerance test.
KYN28A High Voltage Metal-clad Movable Switchgear
| Content | Unit | Value | |
| Rated Voltage | kV | 12 | |
| Rated Current | A | 630~4000 | |
| Rated Frequency | Hz | 50/60 | |
| Power Frequency Withstand Voltage in 1 min | Phase,Earthed | kV | 42 |
| Isolating Fracture | kV | 48 | |
| Lightning Impulse Withstand Voltage(Peak) | Phase,Earthed | kV | 75 |
| Isolating Fracture | kV | 85 | |
| Rated Current of the Main Busbar | A | 630~4000 | |
| Rated Current of the Branch Busbar | A | 630~4000 | |
| Rated Short-circuit Breaking Current | KA | 20/25/31.5/40/50 | |
| Rated Short Circuit Making Current | kA | 50/63/80/100/125 | |
| Rated Short-time Withstand Current(4s) | kA | 20/25/31.5/40/50 | |
| Rated Peak Withstand Current | kA | 50/63/80/100/125 | |
| Frequency Withstand Voltage in 1 min of Aux Control Loop | V | 2000 | |
| Intenal Arc Duration Test(0.5s) | kA | 31.5~40 | |
| Rated Voltage of Aux Control Loop | V | AC or DC 110/220 | |
| Degrees of Protection | IP | IP4X(IP2X when the front door is opened) | |
Main circuit scheme diagram
XGN High Voltage Fixed Type Metal-enclosed Switchgear
Product Summary
XGNfixed type metal-enclosed switchgear is applied 3.6kV\~12kV three phase AC 50/60Hz system which work as indoor apparatus distribution device. It has functions like circuit protection and testing. Its busbar system is single busbar and single busbar with bypass busbar, also can derive dual busbars structure.It complies with GB/T3906 and DL/T404. It has a completely mechanical anti mis-operation locking device which is reliable performance, complete functions, simply structure and convenient operating, it can meet requirements of interlock function of fivepreventions simply and effectively.
Environmental Conditions
●Ambient Temperature: No more than +40C and no less than -15C.Average temperature is no more than +35C within 24 hours.
●Altitude: No more than 1000m.
●Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
●Earthquake Intensity: No more than 8 degrees.
●Vapor pressure: average daily value is no more than 2.2kPa, average monthly value is no more than 1.8kPa.
●Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Product Features
●XGN-12 switchgear uses sealed metal box-type structure, and the framework of cabinet is welded by angle steel and steel sheet
●The cabinet is divided into circuit breaker compartment, busbar compartment, cable compartment and relay compartment, separated by steel plate between two compartments.
●The switchgear was set by a front and a back door. And it is installed away from the wall and could be maintained from both sides.
●A pressure relief channel is provided at the top of thecabinet. If internal arcing fault occurs, it is able to release pressure and discharge gas from the pressure relief channel to ensure the safety of operators.
●The switchgear has a perfect "five-preventions', with simple and clear operation procedures.
●The main circuit breakers that the switchgear usingare ZN28-12, ZN63A, VCA, etc. series vacuum circuit breakers; and other types of circuit breakers can also be used according to the requirements.
●The disconnecting switch is GN30 rotating disconnecting switch or GN22 big current disconnecting switch.
XGN High Voltage Fixed Type Metal-enclosed Switchgear
| Content | Unit | Value | |||
| Rated Voltage | kV | 12 | 24 | 36 | |
| Rated Current | A | 630/1250/1600/2000/2500/3150 | |||
| Rated Frequency | Hz | 50/60 | |||
| Power Frequency Withstand Voltage in 1 min | Phase,Earthed | kV | 42 | 52 | 80 |
| Isolating Fracture | kV | 48 | 58 | 85 | |
| Lightning Impulse Withstand Voltage(Peak) | Phase,Earthed | kV | 75 | 110 | 170 |
| Isolating Fracture | kV | 85 | 120 | 180 | |
| Rated Current of the Main Busbar | A | 630/1250/1600/2000/2500/3150 | |||
| Rated Current of the Branch Busbar | A | 630/1250/1600/2000/2500/3150 | |||
| Rated Short-circuit Breaking Current | KA | 20/25/31.5/40 | |||
| Rated Short-time Withstand Current(4s) | KA | 20/25/31.5/40 | |||
| Rated Peak Withstand Current | KA | 50/63/80/100 | |||
| Rated Short Circuit Making Current | kA | 50/63/80/100 | |||
| Frequency Withstand Voltage in 1 min of Aux Control Loop | V | 2000 | |||
| Degrees of Protection | IP | IP2X | |||
| Rated Voltage of Aux Control Loop | V | AC or DC 110/220 | |||
Main circuit scheme diagram
XGN15 High Voltage Air Insulated SF6 RMU
Product Summary
The RMU is generally divided into air insulated and SF6 insulated types. XGN15 indoor fixed type SF6 RMU uses SF6 switch as its main switch, and air insulation is used for the entire cabinet. It is suitable for 10kVdistribution systems in factories, enterprises, residential districts, high-rise buildings, mines and ports. And it can be combined into ring network system used for power supply and distribution of three-phase AC ring network, biradial power supply unit or line terminal,receiving, distributing and controlling electricpower, and protecting the safety operation of electrical equipment.
Environmental Conditions
●Ambient Temperature: No more than +40C and no less than -15C.Average temperature is no more than +35C within 24 hours.
●Altitude: No more than 1000m.
●Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
●Earthquake Intensity: No more than 8 degrees.
●Vapor pressure: average daily value is no more than 2.2kPa, average monthly value is no more than 1.8kPa.
●Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Product Features
●Modular design. Each unit module can be combined and extended arbitrarily, which is easy to schemes combination, with a wide applicable range.
●The armored structure is used for the cabinet. And each compartment is separated to the other one by metal partition board.
●The corrosion resistant metal is used for the operating mechanism, and bearings of rotating parts are all self-lubricating bearings.The product will not be affected by the environment, thus exempting from regular maintenance.
●In order to adapt to the power grid automation and improve the reliability of power distribution, the electric drive mechanism, control terminal unit of power distribution network and other equipment can be added. Thus, it possesses telemetering, remote signaling and remote control systems.
●The cabinet is compact design, using three-positions rotary load switch, which effectively reduces the number of components and parts, and realizes the five-preventions interlocking.
●The simulated single line diagram of primary circuit and analog display can display the internal conditions of the switch, so that the operation can be simple, correct and safe.
XGN15 High Voltage Air Insulated SF6 RMU
Technical Parameters
| Content | Unit | Value | |||
| Rated Voltage | kV | 12 | 24 | 36 | |
| Rated Frequency | Hz | 50/60 | |||
| Rated Current | A | 630 | |||
| Max. rated Current of Fuse | A | 125 | |||
| Rated Short-circuit Breaking Current | KA | 31.5(Fuse Group) | |||
| Rated Peak Withstand Current | KA | 50 | |||
| Rated Short-time Withstand Current(4s) | kA | 20 | |||
| Rated Short Circuit Making Current | kA | 50 | |||
| Grounding Loop | Ratad Short-time Withstand Current(2s) | KA | 20 | ||
| Rated Peak Withstand Current | KA | 50 | |||
| Power Frequency WithstandVoltage in 1 min | Phase,Earthed | kV | 42 | 52 | 80 |
| Isolating Fracture | kV | 48 | 58 | 85 | |
| Lightning Impulse WithstandVoltage(Peak) | Phase,Earthed | kV | 75 | 110 | 170 |
| Isolating Fracture | kV | 85 | 120 | 180 | |
| Rated Active Load Breaking Current | A | 630 | |||
| Rated Closed Loop Breaking Current | A | 630 | |||
| Rated Cable-charging Breaking Current | A | 10 | |||
| Rated Transfer Current | A | 1750 | |||
| SF6 Gas Pressure(Relative Pressure at 20 °C) | MPa | 0.045 | |||
| Internal Arc Duration Test(0.5s) | kA | 31.5 | |||
| Mechanical Life | Load Switch | Times | 5000 | ||
| Earth Switch | Times | 2000 | |||
| Operation Mode | |||||
| - | Manual/Electric | ||||
Main circuit scheme diagram
SRM□ High Voltage Gas Insulated RMU
Product Summary
SRM Full Gas Insulated RMU is indoor cabinet type AC metal sealed switching device, with AC 10kV and 50/60Hz.It is suitable for distribution systems,ring power supply and biradial power supply system in factories, workplaces, residential high-rise buildings, it possesses functions of receiving, distribution and protection. It can also used in the prefabricated substation.
Environmental Conditions
●Ambient Temperature: No more than +40C and no less than -15C.Average temperature is no more than +35C within 24 hours.
●Altitude: No more than 1000m.
●Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
●Earthquake Intensity: No more than 8 degrees.
●Vapor pressure: average daily value is no more than 2.2kPa, average monthly value is no more than 1.8kPa.
●Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Product Features
●Fully sealed design,all 10kV switches and busbar electrified bodies are sealed in the gas box welded by 3mm stainless steel plate, and the silicon rubber cable plugis applied to achieve the full insulation seal of the cable head, so that it is not affected by external environment such as dust, humidity and small animals.
●The switching device has a perfect "five-preventions", with simple and clear operation procedures.
●Modular design. Each unit module can be combined and extended arbitrarily, which is easy to schemes combination, with a wide applicable range.
●Big capacity for feeder line, small occupation, suitable for a variety of needs, wide range of applications.
●Equipment maintenance-free, highly reliable performance.
SRM High Voltage Gas Insulated RMU
| Content | Unit | C Module | F Module | V Module | CB Module | ||||||||||||||
| Load Switch | Load SwitchWith Fuse | VacuumSwitch | Disconnector/Earthing Switch | Vacuum CircuitBreaker | Disconnector/Earthing Switch | ||||||||||||||
| Rated Voitage | kV | 12 | 24 | 36 | 12 | 24 | 36 | 12 | 24 | 36 | 12 | 24 | 36 | 12 | 24 | 36 | 12 | 24 | 36 |
| Rated Frequency | Hz | 5 | 0/60 | 5 | 0/60 | 50/60 | 5 | 0/60 | 50/60 | 50/60 | |||||||||
| Power Frequency Withstand Voltage in 1 min | kV | 42 | 52 | 80 | 42 | 52 | 80 | 42 | 52 | 80 | 42 | 52 | 80 | 42 | 52 | 80 | 42 | 52 | 80 |
| 48 | 58 | 85 | 48 | 58 | 85 | 48 | 58 | 85 | 48 | 58 | 85 | 48 | 58 | 85 | 48 | 58 | 85 | ||
| Lightning Impulse Withstand Voltage(Peak) | kV | 75 | 110 | 170 | 75 | 110 | 170 | 75 | 110 | 170 | 75 | 110 | 170 | 75 | 110 | 170 | 75 | 110 | 170 |
| 85 | 120 | 180 | 85 | 120 | 180 | 85 | 120 | 180 | 85 | 120 | 180 | 85 | 120 | 180 | 85 | 120 | 180 | ||
| Rated Current | A | 630 | Note(1) | 630 | - | 1250/630 | - | ||||||||||||
| Rated Closed Loop Breaking Current | A | 630 | - | - | - | - | - | ||||||||||||
| Rated Cable Charging Breaking Curent | A | 10 | - | - | - | - | - | ||||||||||||
| Rated Short Circuit Making Current | A | 50 | 80 | 50 | 50 | 63 | 63 | ||||||||||||
| Rated Peak Withstand Current | kA | 50 | - | 50 | - | 63 | - | ||||||||||||
| Rated Short Time Withstand Current | kA/3S | 20 | - | 20 | - | 25 | 一 | ||||||||||||
| Rated Short Circuit Breaking Current | kA | - | 31.5 | 20 | - | 25 | - | ||||||||||||
| Rated Transfer Current | A | - | 1700 | - | - | - | - | ||||||||||||
| Max. Rated current of fuse | A | - | 125 | - | - | - | - | ||||||||||||
| Loop Resistance | μΩ ≤300 ≤600 - 一 - -times 5000 3000 5000 2000 5000 5000 | ||||||||||||||||||
| Mechanical Life | |||||||||||||||||||
MNS Low Voltage Withdrawable Switchgear
Product Summary
MNS low Voltage withdrawable type switchgear is used for conversion, distribution and control of electrical energy of power distribution equipment of AC 50\~60Hz, 400V. It is mainly used in airports, power plants, substations, petrochemical plants, metallurgic plants, steel plants, transportation energy, light textile and residential districts, high-rise buildings, etc.The switchgear conforms to IEC439, GB/T7251.1 and other professional standard. It uses standard module design, and it can respectively form standard unitssuchas protection,operation,conversion, control, regulation, determination and indication. Over 200 types of assembly parts can form frame structures of different schemes, and form fixed separation or drawer units. The users can select assemblies arbitrarily according their demands.
Environmental Conditions
●Ambient Temperature: No more than +40C and no less than -15C.Average temperature is no more than +35C within 24 hours.
●Altitude: No more than 1000m.
●Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
●Earthquake Intensity: No more than 8 degrees.
●Vapor pressure: average daily value is no more than 2.2kPa, average monthly value is no more than 1.8kPa.
●Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Product Features
●The operation of drawer is combined with the control handle. It has simplified the operation, and overcome the shortcomings that the operation of traditional MNS cabinet is complicated.
●The MCC unit has a lot of combinations, with compact structure. The cabinet body can share busbars, which are arranged back to back. A maximum of 36 loops can be assembled for each cabinet.
●The cabinet body can be arranged back toback or against the wall, which can save installation space.
●All of the standard components are selected to facilitate the design of engineering designers
●The whole series is standardized, the structure is versatile and the assembly is flexible.
●It can accommodate more units in a cabinet, and it can be freely combined into different types, such as fixed type and drawer type. The same specification drawer unit can be exchanged conveniently.
●The combination performance is stable and the earth continuity is good.
●The device has a high continuity and reliability.
●The product has passed the aseismic, salt fog and EMC electromagnetic compatibility test, and the operation is safe and reliable.
MNS Low Voltage Withdrawable Switchgear
Technical Parameters
| Content | Unit | Value | |
| Rated Operational Voltage | V | 400 | |
| Rated Insulation Voltage | V | 690 | |
| Rated Frequency | Hz | 50/60 | |
| Main Bus-Bar | Rated Current | A | ≤6300 |
| Rated short time withstand current(1S) | kA | ≤100 | |
| Rated Peak Withstand Current | KA | ≤220 | |
| Distribution Bus | Rated Current | A | ≤1300 |
| Rated short time withstand current(1S) | kA | ≤50 | |
| Rated Peak Withstand Current | kA | ≤105 | |
| Frequency Withstand Voltage in 1 min of Aux Control Loop | kV | 2 | |
| Rated Impulse Withstand Voltage | kV | 8 | |
| Degrees of Protection | IP | IP40 | |
| Electrical Clearance | mm | ≥10 | |
| Creepage Distance | mm | ≥12.5 | |
| Overvoltage Level | - | II //V | |
| Pollution Degree | 一 | 3 | |
Main circuit scheme diagram
GCS Low Voltage Withdrawable Switchgear
Product Summary
GCS lowVoltage withdrawable switchgear is suitable for the low voltage distribution system in power plant, petroleum industry, chemical industry, metallurgy industry, spinning mill, high buildings, etc. It is especially used in large power plant, petrochemical systemand other locations which are required high automatic and computer interface. It is serviced in the low voltage apparatus distribution devices of generator and power supply system distribution, motor central control and reactive power compensate of 3 phase AC 50/60Hz, 400V, rated current 4000A and lower.
Environmental Conditions
●Ambient Temperature: No more than +40C and no less than -15C.Average temperature is no more than +35Cwithin 24 hours.
●Altitude: No more than 1000m.
●Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
●Earthquake Intensity: No more than 8 degrees.
●Vapor pressure: average daily value is no more than 2.2kPa, average monthly value is no more than 1.8kPa.
●Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Product Features
●It can be increased the thermal capacity of adaptor parts. Also it can be effectively and evidently reduced the temperature rise of adaptor parts or additional temperature rise of cable lug andpartition board.
●The quantity of a single MCC panel' s loop is up to 22 Nos., this can satisfy requirements of power plant which has high capacity of single generator, automatic motor control door (machine) set of petrochemical system and other industries.
●The connection between the device and the external cable is completed in the cable compartment, and the cable can get in and out on the top or bottom. The zero sequence current transformer is placed in the cable compartment, so that the installation and maintenance are convenient.
●Drawer units have enough quantity secondary adaptors (32 pairs for 1 unit and above, 20 pairs for 1/2 unit), so it can meet the requirements of the number of contacts by the computer interface and the automatic control loop.
GCS Low Voltage Withdrawable Switchgear
| Content | Unit | Value | |
| Rated Operational Voltage | V | 400 | |
| Rated Insulation Voltage | V | 690 | |
| Rated Frequency | Hz | 50/60 | |
| Main Bus-Bar | Rated Current | A | ≤4000 |
| Rated short time withstand current(1S) | KA | ≤80 | |
| Rated Peak Withstand Current | kA | ≤176 | |
| Distribution Bus | Rated Current | A | ≤1500 |
| Rated short time withstand current(1S) | KA | ≤50 | |
| Rated Peak Withstand Current | KA | ≤105 | |
| Frequency Withstand Voltage in 1 min of Aux Control Loop | kV | 2 | |
| Rated Impulse Withstand Voltage | kV | 8 | |
| Degrees of Protection | IP | IP40 | |
| Electrical Clearance | mm | ≥10 | |
| Creepage Distance | mm | ≥12.5 | |
| Overvoltage Level | - | II/IV | |
| Pollution Degree | - | 3 | |
Main circuit scheme diagram
GCK Low Voltage Withdrawable Switchgear
Product Summary
GCK low Voltage withdrawable switchgear consists of two parts, power distribution center (PC Panel) and motor control center (MCC Panel). It is universally applied in power plant, citysubstations, industry and mine corporations,etc., with rated voltage 400V, max operating current 4000A and rated frequency 50/60Hz. It can be applied as power conversion distribution controlof the powerdistribution equipment like power distribution, electromotor control, lighting, etc.This switchgear is accordance with internationalstandard IEC439and national standard GB7251(lowVoltage switchgear and controlgear assemblies). The main characteristics are high breaking capacity, good performance of dynamic & thermal stability, advanced and reasonable configuration, realistic electric scheme, and strong seriation and generality. All kinds of scheme units are combined arbitrarily. A cabinet has more loops to be accommodated, which has many advantages like saving area, beautiful appearance, high degrees of Protection, safety and reliability, and convenient maintenance, etc.
Environmental Conditions
●Ambient Temperature: No more than +40C and no less than -15C.Average temperature is no more than +35C within 24 hours.
●Altitude: No more than 1000m.
●Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
●Earthquake Intensity: No more than 8 degrees.
●Vapor pressure: average daily value is no more than 2.2kPa, average monthly value is no more than 1.8kPa.
●Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Product Features
●The basic frame of this series of products is a combination assembly structure, All the structural components of the rack can be connected to each other through screws to form a basic frame. Then, a complete switchgear can be assembledaccording to the needs of the door, baffle, partition board, drawer, mounting bracket, busbar and electrical components.
●The frame adopts special-shaped steel and is positioned by three dimensional plates: bolt connection without welding structure, so as to avoid welding deformation and stress, and improve installation accuracy. The installation holes of frames and components change according to modulus E=25mm.
●The internal structure is galvanized, and the surface of the panel, the side plate and the panel are treated by acid washing and phosphating, and the electrostatic epoxy powder is used.
●In the power center (PC) incoming cabinet, the top is the horizontal busbar area, and the lower part of the horizontal busbar is the circuit breaker room.
GCK Low Voltage Withdrawable Switchgear
| Content | Unit | Value | |
| Rated Operational Voltage | V | 400 | |
| Rated Insulation Voltage | V | 690 | |
| Rated Frequency | Hz | 50/60 | |
| Main Bus-Bar | Rated Current | A | ≤4000 |
| Rated short time withstand current(1S) | kA | ≤80 | |
| Rated Peak Withstand Current | KA | ≤176 | |
| Distribution Bus | Rated Current | A | ≤1500 |
| Rated short time withstand current(1S) | kA | ≤50 | |
| Rated Peak Withstand Current | kA | ≤105 | |
| Frequency Withstand Voltage in 1 min of Aux Control Loop | kV | 2 | |
| Rated Impulse Withstand Voltage | kV | 8 | |
| Degrees of Protection | IP | IP40 | |
| Electrical Clearance | mm | ≥10 | |
| Creepage Distance | mm | ≥12.5 | |
| Overvoltage Level | - | II//V | |
| Pollution Degree | 一 | 3 | |
Main circuit scheme diagram
GGD Low Voltage Fixed Type Switchgear
Product Summary
The GGD low voltage switchgear is applied in power plant, substations, industry and mine corporations, etc., with rated voltage 40oV, max operating current 4000A and rated frequency 50/60Hz. It can be applied as power conversion distribution control, distribution and control of power, lighting and power distribution, etc.The cabinet structure of GGD type adopts the form of general cabinet, the frame is assembled by local welding of cold bending section steel, so it is firm and solid. The parts of the general cabinet are designed according to the principle of module, and have the installation hole with 20mm as the module, and the common coefficient is high. It can make the factory realize the pre production, not only shortens the production cycle, but also improves the working efficiency.
Environmental Conditions
●Ambient Temperature: No more than +40C and no less than -15C.Average temperature is no more than +35Cwithin 24 hours.
●Altitude: No more than 1000m.
●Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
●Earthquake Intensity: No more than 8 degrees.
●Vapor pressure: average daily value is no more than 2.2kPa, average monthly value is no more than 1.8kPa.
●Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Product Features
●The frame has sufficient strength and rigidity, Which can withstand the mechanical stress and electrodynamic force generating from installation components and short circuit, At the same time it does not affect the performance of the device because of the hoisting and transportation of the device, etc.
●When the cabinet is designed, the heat dissipation in the operation of the equipment is fully taken into account. There are different number of radiating slots in the upper and lower ends, heat is going up when the electrical components in the cabinet are heating, and is discharged through the top slot, and the cold wind constantly from the bottom slot is supplied into the cabinet, the sealed cabinet body bottom forms a natural ventilation from bottom to top, which achieves the purpose of heat dissipation.
●The instrument door equipped with the electrical components is connected with the frame with many annealed copper wires. The installation parts in the cabinet are connected to the frame with the knurled screws, and the whole cabinet forms a complete grounding protection circuit.
●The cabinet cover can be removedif necessary, to facilitate the main bus assembly and adjustment on site. Flying rings are provided at the four comers of the cabinet top for lifting and shipping.
GGD Low Voltage Fixed Type Switchgear
| Content | Unit | Value | |
| Rated Operational Voltage | V | 400 | |
| Rated Insulation Voltage | V | 690 | |
| Rated Frequency | Hz | 50/60 | |
| Main Bus-Bar | Rated Current | A | ≤4000 |
| Rated short time withstand current(1S) | KA | ≤80 | |
| Rated Peak Withstand Current | kA | ≤176 | |
| Distribution Bus | Rated Current | A | ≤1500 |
| Rated short time withstand current(1S) | KA | ≤50 | |
| Rated Peak Withstand Current | kA | ≤105 | |
| Frequency Withstand Voltage in 1 min of Aux Control Loop | kV | 2 | |
| Rated Impulse Withstand Voltage | kV | 8 | |
| Degrees of Protection | IP | IP40 | |
| Electrical Clearance | mm | ≥10 | |
| Creepage Distance | mm | ≥12.5 | |
| Overvoltage Level | - | II//V | |
| Pollution Degree | - | 3 | |
Main circuit scheme diagram
GWB Low Voltage Reactive Power Compensation Device
Product Summary
GWB series low voltage reactive power compensation cabinet is suitable for low voltage power grid with AC 50/60Hz and rated voltage 400V, so as to improve power factor, reduce line loss and improve power quality. The intelligent controller is the core of the system, which uses switching devices to automatically switch capacitors according to the power factor of the grid, ensuring that the power grid always has high power factor.
Environmental Conditions
●Ambient Temperature: No more than +40C and no less than -15C.Average temperature is no more than +35C within 24 hours.
●Altitude: No more than 1000m.
●Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
●Earthquake Intensity: No more than 8 degrees.
●Vapor pressure: average daily value is no more than 2.2kPa, average monthly value is no more than 1.8kPa.
●Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
Product Features
●The product structure is versatile and can be combined with MNS, GCK, GCS, GGD and many other low Voltage switchgears.
●The compensation mode is flexible and diverse, which could be three phase compensation, single phase compensation and three phase single phase mixed compensation.
●It could be connected to comprehensive automatic system with many communication ports like Rs485, GPRS, etc.
●According to the operation of the power grid, various switching modes, such as AC contactor, semiconductor switch, compound switch and so on, are adopted.
●Afterseries connecting the reactor, the harmonic of the power grid can be suppressed effectively and the quality of the power grid can be improved.
GWB Low Voltage Reactive Power Compensation Device
| Content | Unit | Value |
| Rated Voltage | V | 400 |
| Rated Insulation Voltage | V | 690 |
| Rated Frequency | Hz | 50/60 |
| Rated Capacity | kvar | 60~530 |
| Operating Voitage | Rated Voltage of 0.85 to 1.10 times | |
| Max.Alowable Overcurrent | 1.3times Rated Current | |
| Number of circuits controled | 4-12 | |
| Switching Delay Time | 0-999S Adjustable | |
| Operation Mode | Automatic, Continuous Operation | |
| Power Factor of Load Terminal | The load changes from 5 to 100%, the P.F values remains above 0.95. |
Main circuit scheme diagram
LV Distribution Board
Product Summary
The LV Distribution board made of CRCA GI sheet galvanized steel, Including housing AMR Meter, CTs, MCBs, MCCBs, LV Busbars.
Application standard: IEC60439
Service Conditions
| Altitude(above sea level) | 1,600m |
| Maximum outdoor temperature | 40℃ |
| Minimum outdoor temperature | -1℃ |
| Maximum monthly mean temperature | 35℃ |
| Annual mean temperature | 25℃ |
| Maximum relative humidity | up to 96% |
| Isokeraunic level | 180 thunderstorms days per year |
| Maximum lightning flash rate | 32 strokes per km² per year |
| Maximum wind velocity | 100km/h |
| Maximum solar radiation(insolation)on plan | 1035W/m² |
| Maximum soil temperature(at 1m depth) | 30℃ |
| Maximum soil themal resistivity | 2℃m/W |
| Maximum soil electricity resistivity | 2000 Ωm |
| Seismic zone(Modified Mecalli Scale) | Zone 8 |
| Earthquake factor | 0.15 |
| Type of atmosphere | Coastal |
| Atmosphere pollutants | Sand, Dust, Salt |
| Polution | Design pollution level to be taken as"Heavy"(pollution level I )accordingto IEC 60815 |
| Item | Unit | Specification | ||
| Type/Model | 50KW | 100KW | 200KW | |
| Protection grade | IP | 55 | 55 | 55 |
| Shell thickness | mm | 1.2 | 1.2 | 1.2 |
| Size | mm | 800×600×350 | 800×700×350 1 | 400×1000×350 |
| Material | Sheet steel | Sheet steel | Sheet steel | |
Ready Board
SUFFICIENT LIGHT AT NIGHT, DURABLEFOR A LONG TIME
●Simple disassembly
●Stable brightness
●Flame retardant material
●Durable and reliable
●Distribution boxes for flexible current supply, portable and handy
●High resistance to weatheringand chemicals
●All combinations are tested for electrical safety and qualityIP65/1P67 protection degree against dust and liquid bodiesIK8 mechanical protection
●Degree High quality thermoplastic material
●Available component preset as requested
●Widely used in the following sites, such as:
●Repair, extension and demolition, work on existing buildings,Construction sites, Exhibition center, Factories
●Application standard:IEC 60364, IEC 60364-7-717, IEC 60529,IEC61008