Commercial vehicle solutions
Power distribution
Commercial vehicle solutions
Power distribution
Series LMG
MultipleAMGfuseholder
Eaton offers a heavy duty power distribution module called the LMG used for main branchprimaryfusing and accepts multiple(two,three orfive)industry standard AMG (mega) fuses. Using a common input bus bar, the LMG requires just one input connection to power all fuses,providing efficient power distribution suitablefor challenging applications.
Specifications
·Sizing:2,3 and5positions available
·Ratings: Maximum total combined rating is 300A continuous
·Temperature: \angle40°F -40°\mathsf{C}) to 185°F (85°\mathsf{C}) Termination:5/16-18orM8studs, nuts and lockwashersforfuse and surface mounting
Torques:
·Mounting: 100 in-lbs max ·Powerinput/output:120in-lbsmax
Material:
·Housing:BlackUL94-V0 thermoplastic
·Cover:RedEPDMcoverforprotection from accidental shorts
·Studs:Plated steel
Options
Fuse options:LMGsmaybe supplied withvariousfuse configurations. If fuses are selected,the input side of fuses aretorqued to specification atEatonfactory andgivena custom part number.
·Mounting hardware: Installed or in bulk (English/Metric available)
·Cover: Installed, in bulk or no cover.
Notes
·Based on numerous variations possible between#of LMG poles,fuses selected, input wiring and output wiring, all applications should be tested by the installer to verifytheproductmeetstheirrequirements.
·Housing must not exceed \boldsymbol{130°C} :
Commercial vehicle solutions
Power distribution
| Pole | "X" mm |
| 2 | 25 |
| 3 | 50 |
| 5 | 50 |
| 5 (ALT) | 100 |
Commercial vehicle solutions
Power distribution
Series LMI
ConfigurativeAMlfuseholdersystem
The LMl fuse holder series can be used for main branch primary fusing and accepts multiple (up tp six) industry standard AMI (midi)fuses.Sold by individual component piece or assembled,the LMl uses a common input bus bar for assemblies of two or more fuses.
The LMl provides efficient power distribution suitable for many applications,such as marine,construction,agriculture,heavy trucking,bus and specialtyvehicles.
Specifications
Sizing:One fuse module per AMIfuse,one input module and bus bar required perLMI2-LMI7assembly, maximumofsevenmodules per assembly ·Ratings:Maximumtotalcombined rating is 400A continuous\* Temperature: -40°F \boldsymbol{-40°C)} to 185°F (85°\mathsf{C})
Termination:
Inputmodule:StainlessSteelM8or 5/16-18 stud and keps nut Fusemodule:StainlessSteelM5or #10-32 studs and keps nuts
Torques:
·Mounting:22in-lbs max ·Input module: 75 in-lbs max ·Fuse module: 39.8 in-lbs max
Material:
·Housing: HTN black UL 94-V0 thermoplastic
·Cover:Red EPDM/Santoprene cover for protection from accidental shorts
·Studs: Stainless Steel
Options
Allmodules(inputorfuseholder)wil matchsame unitsin a given assembly, either all metric orall English, as specified.
"E"represents "10–32" stud for fuse modules and "5/16-18" for input module. "M" represents M5 stud for fuse module annd M8x1.25 size forinput module.
The largest possible LMl assembly that canbecreatedis7modulestotal;6fuse modules and one input module.At most, 7 positions can be shown in suffix -X(XXXXX).
Eatondoesnotrecommendmorethan 6 bussed fuse modules being connected together (with one input module).The inputmoduleshouldbelocatedinthe centeroftheassemblyforbusbar efficiencies
Busbarsareincludedforallassemblies greaterthanorequaltoanLMl2
All modules come with covers.
Whenordering individual LMl modules for assembly by the customer,bus bars can be individually ordered using part number B109-7046-x (where "x" represents the number of totalmodules, including input module,that thebus bar will connect)
When ordering LMl1 with fuse and/or nuts, both fuse and nuts will ship bulk.
To order assembled units,the minimum orderquantityis100units.
Attach all wire cables with the ring terminalsindirectcontactwith thefuse orbar(i.e.nofastenersorwashers betweenringterminal andfuse/bussbar)
Basedonnumerousvariationspossible between numbers ofpoles used,fuses selected, input wiring and output wiring, allapplicationsshouldbetestedby installer to verify the product meets their requirements.
| Item | Description |
| 1 | LMI fuse module |
| 2 | LMI input module |
| 3 | Bus bar |
| 4 | AMI fuse |
Commercial vehicle solutions
Power distribution
Ordering information
Commercial vehicle solutions
Power distribution
Series15700-RTA
RearterminalATCfusepanel
The Rear Terminal ATC? Fuse Panel (RTA) is a rear-fed panel with high component retention,which makes it anideal choice for high vibration environments including construction,agriculture,bus,recreational vehicles,heavy trucking equipment,etc. It is available in multiple lengths and internal bussing configurations.This allows for up tofourseparatepowerinputcircuits and32individualoutput circuits.
Specifications
Input terminal rating: 1/4-20 stud; quick-connect terminalsprovided on middle bus (Series 15713 & 714); 200A max total input for unit Output terminal rating:30A max load per circuit
·Temperature rating: -40°F (-40°\mathsf{C}) to 260°\mathsf{F} (125°\mathsf{C})
·Materials: UL 94 V-0 thermoplastic
Termination:
Options
·Positions:8-32circuitsavailable
·Splitpower:Single,dual,triple or quadruplebus options
·Cover: Short cover for fuses only and taller coverforusewith circuitbreakers
·Locks:Secondarylocs availablefor securingofoutput terminals (#15710-TP -comes in multiples of 8 positions. Must order multiple strips to cover length of selected RTA).
·12020321 (16/14AWG) 12020400 (12/10AWG)
·Aptiv Pack-ConSeries 3&5
·Input wire size: #4-6AVVG
·Outputwiresize:#10-16AWG
·TorqueRating:50in-lbsmax
·Mounting torquerating:#10-32 threaded inserts, 24 in-lbs max torque
Note:
·Consult Aptiv distribution for availability ·ForSeries15712and15713 thereis amaximum total of 32positions and mustbe inincrements of 4.
Commercial vehicle solutions
Power distribution
15711-Minimum8Positions
15712-Minimum12Positions
15713-Minimum16Positions
Dimensions in inches (mm)
| Dim'A'value | Dim'B'value | |
| 8 POLE | 28.0 | 47.5 |
| 12 POLE | 48.0 | 67.0 |
| 16 POLE | 67.8 | 87.0 |
| 20 POLE | 87.5 | 107.0 |
| 24 POLE | 107.0 | 126.5 |
| 28 POLE | 127.0 | 146.5 |
| 32 POLE | 147.0 | 166.5 |
Commercial vehicle solutions
Power distribution
Series 15600
ATCTypefusepanel
The 15600 ATC?fuse panel is a compact power distribution module.It is available ina single or dual internal bus electrical configuration featuring an optional ground pad terminal strip.The 15600 fuse panel is surface mounted,uses convenient quickconnect terminals and isrecommended as a supplemental power distributionmodule.
Specifications
Inputterminalrating: \#10–32 threaded studs (100A max) ·Outputterminalrating:30Amax per circuit Temperaturerating: 0°\mathsf{C} (-20°F) to 65°\mathsf{C} *150°F) ·Materials:UL94V-0 thermoplastic Termination: 0.250^{\prime\prime}x0.032^{\prime\prime} quick-connectterminals\* ·Ground terminal pad option available ·Input wire size: #4-6 AWVG
·Outputwire size:#12-16AWG ·Torque Rating: 20 in-lbs max ·Mounting torque rating:8in-lbsmax
Options
·Positions:4-20circuitsavailable ·Splitpower:Singleordual bus options
Commercial vehicle solutions
Power distribution
| No.of fuse"C" | 15600 "" | 15602 "" | |
| 04 | 1.84 | 2.44 | |
| 06 | 0.62 | 2.47 | 3.06 |
| 08 | 1.25 | 3.09 | 3.688 |
| 10 | 1.87 | 3.75 | 4.32 |
| 12 | 2.50 | 4.34 | 4.94 |
| 14 | 3.12 | 4.97 | 5.56 |
| No.of fuse | "C" | 15600 "" | 15602 "" |
| 16 | 3.76 | 5.59 | 6.19 |
| 18 | 4.37 | 6.22 | 6.81 |
| 20 | 5.00 | 6.84 | 7.43 |
Commercial vehicle solutions
Power distribution
Series37700-PFM/PRM
Powerfusemodules(PFM) Power relay modules (PRM)
Eaton offers a sealed Power Relay Modue (PRM) along with an accompanying Power Fuse Module (PFM).These compact power distribution modules are designed for high current applications and are suitable for placement in high moisture and vibration environments.
The PRM contains a relay and two female Maxi fuse positions.One of these fuses protects the relay and the other is a single-circuit inline fuse.The PFM contains only twofuses-eacha separate circuit.A siliconesealandremovablecover offer a weather-tight enclosure(IP66)for thefusepositions.
PRMs/PFMs also feature rugged M8 power input studs with output options that include terminal studs (M6) or sealed (IP66) connector (PRM only). Multiple units may be connected togethervia a custom buss bar or canbebussed to any of theEaton PDMs(i.e.the 31000/32000 Series VEC/DVEC,15300Series RTMR,etc.).
PRMWiring
Specifications
·PRM rating:60A, 12VDC steady-state relay;or 25a,24VDC steady-state relay
·Relay protectionfuse:Up to60Afor 12V relay & 30A for 24V relay
·Nonswitched Inline fuse:Up to 60A (12V or 24V)
·PFM rating: each inline fuse rated up to60A
·Materials:UL94-V0thermoplastic (excluding cover);silicone seal; tin-platedcopper terminals; plated steel studs
·Inputtermination:M8threadedstud
·PRM switching/trigger signal connector:AptivMetri-Pack150 SeriesorAMPSEAL?16(dependent upon part number configuration) Outputtermination:TwoM6 threaded studs orEatonSeries32004 sealed connector(PRMonly);accepts AptivPackard800seriesterminals.
Torque ratings:
Options
·Mounting:Counter rotation feature (CRF) available to prevent rotation on singlebolt installations
·Bussing: Custom bussing available for joining multiple PRMs/PFMs;options alsoavailableforbussingPRMs/PFMs tootherEatonPDMs
Accessories:Buss bar, stud cap
Signal connector part numbers:
Ingressprotectionrating:IP66 (excluding stud connections) Compliances:SAE31171 (ignition protected)
·AptivBlack-12052641; grey-12052644 (consult Aptiv distribution)
·AMP:Red-776427-1; grey -776427-2; yellow -776427-3; green - 776427-4 (consult Tyco distribution)
Standards&certifications
·Input stud:144in-lbs max ·Output stud: 48in-lbs max ·Mounting:48in-lbs max
Commercial vehicle solutions
Power distribution
Dimensions in inches (mm)
37701-1NSeries
Commercial vehicle solutions
Power distribution
Commercial vehicle solutions
Power distribution
HMG Fuse holder
The HMG fuse holder accepts industry standard AMG (Mega) fuses for primary fusing applications.The narrow rugged body makes it ideal for demanding environments such as‘under the hood'locations in construction,agriculture,heavy trucking and specialty vehicle applications.
Specifications
Rating:For use with AMG (Mega) fuses from 100A-300A Temperature rating: -40°F (-40°C) to 260°\mathsf{F} (125°\mathsf{C}) ·Materials: UL 94 V-0 thermoplastic withzinc-platedsteelstuds Termination:M8or5/16-18threaded studs and hex nuts for fuse mounting. Wire sizes:#8AWG-1/0 Torquerating:150in-lbsmax ·Mounting torque rating:Optional mounting hole patterns, 44 in-lbs max
Features
·Side-stackable
·Bottomsidecanbeinsulatedfrom the mounting panel
·Splashresistantcover
Commercial vehicle solutions
Power distribution
FMG Fuse holder
The FMG fuse holder accepts industry standard AMG fuses for primary fusing applications.The FMG is offered with a tough elastomer coverfor fuse protection, yet allows for cable input from various orientations.Thisfuse holder coveris available in multiple colors and lengths.Similar to the Eaton HMG holder, the FMG is well suited for demanding environments such as‘under the hood'locations in construction, agriculture,heavy trucking and specialty vehicle applications.TheFMGfuse holder allows forfullaccess for cables and canbe routed to studsfrom nearly every direction.
Specifications
Rating:ForusewithAMGfusesfrom 100A-500A
Temperaturerating: -40°F \mathsf{-40°C}) to 260°\mathsf{F} (125°\mathsf{C})
·Materials:Blackthermoplasticwith zinc-plated steel studs;thermoplastic cover available inblack orred, innormalorextendedlength Termination:M8or5/16-18threaded studs and hex nuts for fuse mounting. Wire sizes:#8AWG-1/0
·Torque rating: 120 in-lbs max
·Mounting torque rating:1/4-20 screwswithwashers(recommended), 44 in-lbs max
Options
Extendedcoveravailable
Ordering information
Commercial vehicle solutions
Power distribution
Dimensions in inches (mm)
Commercial vehicle solutions
Power distribution
Series CFH
Connectorfuseholder
The Connector Fuse Holder (CFH) is a smalleasy-to-use power distribution module which can hold up to four 2.8\mathsf{mm} footprintprotective devices.Designed toholdrelays, circuit breakers,fuses,diodes,resistors and/or transorbs,the CFH isready to support all of yoursmall orlastminutepower distributionrequirements.Options include color of connector, length of cover and type of bracket.Qualified to IP66 foringress protection,this product canbe installed where required to eliminate excess wiring.
Specifications
Maxamperage:TheCFH islimited to a total of 100A maximum rating whendesignedunderSAEguidelines. Terminal limitations are according toAptivMetri-pak280guidelines (consultAptivdocumentation) ·Temperaturerating: -40°F \mathsf{-40°C}) to 260°F 125°C)
Materials:
·Cover:UL94-V0clearpolycarbonate ·Connector:UL94-V0 thermoplastic ·Brackets: Side and end -zinc plated steelwithchromatefinish
Note:
Servicable parts:
·Cover:B151-7184-S(fuse)or B151-7184-L (relay/breaker) ·Brackets:B028-7013(side bracket); B028-7015-SRV (end bracket); B028-7016-SRV(pinbracket)
Terminals, seals and plugs are not included.
Connector uses AptivMetri-Pack sealed /Tang style terminals,seals and plugs.(consult Aptiv distributionforavailability)
Ordering information
Commercial vehicle solutions
Power distribution
Commercial vehicle solutions
Power distribution
ATCblade-type fuses
·HHC,HHFHHG and HHR ·Rating: 32\vee; see tableformaximum amperage · "Write-in" space for circuit identification on HHC holder · HHR holder has a locking cover and mounting hole
ATMMiNIblade-typefuses
·HHL and HHM ·Rating: 32\vee; see table for maximum amperage ·Body material withstands high temperatures ·Protective cover has removable straps
MAXI"fuses
·HHX
·Rating: 32V, 60A maximum
·Firewall mounting hole permits two or more holders tobemountedtogether
·Cover comes with removable strap
Commercial vehicle solutions
Power distribution
| Catalog number | Description | Fuse size | Electricalconnection |
| ATCblade typeholder | |||
| HHC | Yellow fuse holder(body only) | 1A -20A | #16 AWG lead black wire |
| HHF | Black fuse holder with cover | 1A - 20A | #16 AWG lead yellow wire |
| HHG | Black fuse holder with cover | 1A-30A | #12 AWG lead yellow wire |
| HHR | Blackwaterproof fuseholderwith locking cover andmounting hole | 1A - 30A | #12 AWG lead orange wire,5" length |
| MINIFuse blade typeholder | |||
| HHL | Fuse holder with cover | 2A - 20A | #16 AWG lead black wire; 4" length |
| HHM | Fuse holder with cover | 2A - 30A | #12 AWG lead red wire; 4"lIength |
| MAXIFuse bladetypeholder | |||
| HHX | Fuse holder with cover | 20A - 60A | #6 AWG lead wire; 5" length |
Dimensions in inches (mm)
Commercial vehicle solutions
Power distribution
Stud type junction blocks
Single stud type junctionblocks
With a maximum torque rating at 48 in-lbs, the single stud type junction blocks are ideal forheavy-duty ground orpower connectionpoints in AC or DC circuits. The modular design offers design and manufacturing flexibility withfeed thruorstand alonemount options available for transformers, communicationandcomputerpower sectionsalongwithvariousvehicle electrical systems.
Non feed-thru multiple stud type
SeriesC4559(#10-24)and C6083(#10-32)
Rating: 30A,600V
Temperature rating: 250°\mathsf{F} 120°C)
Materials:Black thermoplasticwith zinc-plated steelstuds
Termination:Threaded studs on 0.750^{\prime\prime} centers. Studs feature a'dog point’to guide nut onto thread
Torque rating: 25 in-lbs max
Mounting torque rating: 24 in-lbs max
Series C5237and JB1032(Nob0sses between studs)
Rating:UL:30A,300V; CSA:30A,600V
Temperature rating: 250°F 120°C)
Materials:Blackthermoplasticwith yellow zinc-plated brass studs.
Termination: \#10–32 threaded studs on 0.625^{\prime\prime} centers.Studs feature a'dog point' to guide nut onto thread
Torque rating: 25 in-lbs max
Mounting torque rating:24 in-lbs max
Postions: 1- 15 positions available
Postions: 2- 16 positions available
Single stud type junctionblocks
Please see thefollowing page for specific part numbers and ordering information.
SeriesC4559andC6083
Please see the following page for specific part numbers and ordering information.
Numbers and arrows molded on top of barriers indicate terminals.
SeriesC5237andJB1032(Nobossesbetweenstuds)
Please see the following page for specific part numbers and ordering information.
Numbers and arrows molded on top of barriers indicate terminals.
Commercial vehicle solutions
Power distribution
| Thread/stud size | Amperages(A) |
| #10 | 50 |
| #1/4 & M6 | 100 |
| #5/16 | 200 |
| #3/8 | 250 |
| #1/2 | 400 |
Dimensions in inches \left(\mathbf{m}\mathbf{m}\right)
Letters correspond to tables on following pages
JB1032-120-XX (No bosses between studs) (A,B,C Dimensions ars the same as C5237)
Commercial vehicle solutions
Power distribution
| Part number | A | B | C |
| Series C4559 | |||
| C4559-2 | 3.00(76.2) | 2.25(57.1) | 0.75 (19.0) |
| C4559-3 | 3.75 (95.2) | 3.00(76.2) | 1.50 (38.1) |
| C4559-4 | 4.50 (114.3) | 3.75 (95.2) | 2.25(57.1) |
| C4559-5 | 5.25 (133.3) | 4.50 (114.3) | 3.00(76.2) |
| C4559-6 | 6.00 (152.4) | 5.25 (133.3) | 3.75 (95.2) |
| C4559-7 | 6.75 (171.4) | 6.00 (152.4) | 4.50 (114.3) |
| C4559-8 | 7.50 (190.5) | 6.75 (171.4) | 5.25(133.3) |
| C4559-9 | 8.25 (209.5) | 7.50 (190.5) | 6.00 (152.4) |
| C4559-10 | 9.00 (228.6) | 8.25 (209.5) | 6.75 (171.4) |
| C4559-11 | 9.75 (247.6) | 9.00 (228.6) | 7.50 (190.5) |
| C4559-12 | 10.50 (266.7) | 9.75 (24.6) | 8.25 (209.5) |
| C4559-13 | 11.25 (285.7) | 10.50 (26.7) | 9.00 (228.6) |
| C4559-14 | 12.00 (308.4 | 11.25 (285.7) | 9.75 (24.6) |
| C4559-15 | 12.75 (323.8) | 12.00 (308.4) | 10.50 (266.7) |
| C4559-16 | 13.50 (342.9) | 12.75 (323.8) | 11.25 (285.7) |
| SeriesC5237 | |||
| C5237-1 | 2.00(50.8) | 1.25 (31.7) | |
| C5237-2 | 2.62 (66.7) | 1.87 (47.5) | 0.625 (15.9) |
| C5237-3 | 3.25 (82.5) | 2.50 (63.4) | 1.25 (31.7) |
| C5237-4 | 3.87 (98.4) | 3.12 (79.4) | 1.87 (47.5) |
| C5237-5 | 4.50 (114.3) | 3.75 (95.2) | 2.50 (63.4) |
| C5237-6 | 5.12 (130.8) | 4.37 (111.1) | 3.12 (79.4) |
| C5237-7 | 5.75 (146.0) | 5.00 (127.0) | 3.75 (95.2) |
| C5237-8 | 6.37 (161.9) | 5.62 (142.9) | 4.37 (111.1) |
| C5237-9 | 7.00(177.8) | 6.25 (158.7) | 5.00 (127.0) |
| C5237-10 | 7.62 (193.7) | 6.87 (174.6) | 5.62 (142.9) |
| C5237-11 | 8.25 (209.5) | 7.50 (190.5) | 6.25 (158.7) |
| C5237-12 | 8.87 (225.4) | 8.12 (206.4) | 6.87 (174.6) |
| C5237-13 | 9.50 (241.3) | 8.75 (222.2) | 7.50 (190.5) |
| C5237-14 | 10.12 (257.2) | 9.37 (238.1) | 8.12 (206.4) |
| C5237-15 | 10.75 (273.0) | 10.00 (254.0) | 8.75 (222.2) |
| Part | Fig. | A | C | D | F | G | H | J | K | L | M | Max. torque (in-lbs) | Material | Color | ||
| C1925* | 1 | 2.7.53 | 136.1 | 13253 | 137.53 | 3.5 | (4.8) | (20.8) | 1/2-13 | 300 | Red | |||||
| C1925B* | 1 | 2.75) | 138.1 | 132.53 | 13.5 | (48 | (50.8) | 1/2- 13 | 300 | Black | ||||||
| C1925-1* | 1 | 2.7.6 | 138.1 | 132.53 | 13.53 | (35) | (48 | (48 | (20.8) | 1/2 - 13 | 300 | Thermolestes | Red | |||
| C1925-1B* | 1 | 2.7.53 | 138.1 | 13.5 | 132.53 | 1212 | (3.5) | (48) | (48 | (50.8) | 1/2 - 13 | 300 | Black | |||
| C1925-2* | 1 | 2.7.53 | 138.1 | 132.53 | 132.53 | 12126 | (35 | (49) | (48 | (50.8) | 3/8 -16 | 150 | Red | |||
| C1925-2B* | 1 | 2.7.5) | 138.1) | 13.53 | 13.5 | 1212 | (48 | (48) | (208) | 3/8 - 16 | 150 | Black | ||||
| C1933 | 1 | 2.7.6) | 13640) | 132.53 | 138.1 | (3.5) | None | (48 | None | (50.8) | .22 dia. | 1/2-13 | 300 | Black | ||
| C1933-1 | 1 | 2.73 | (363) | 13.5) | 138.1 | 1282 | (3.5 | None | (4.8 | None | (50.8) | .22 dia. | 5/16 - 18 | 75 | Black | |
| C1938* | 2 | (524 | (23.8 | (675)1 | (22 | (675)1 | (3.9) | (23.8) | (16) | 133) | 3/8-16 | 200 | Black |
Commercial vehicle solutions
Power distribution
| Part | Fig. | A | B | C | D | E | F | G | H | J | K | L | M | (in-lbs) | Material | Color |
| C1938R* | 2 | (504) | (23.8) | (2) | (675)1 | (3.9) | (23.8 | (06) | (06) | 13 | 3/8- 16 | 200 | Red | |||
| C1938-1* | 2 | (524) | (23.8) | (22 | (175)1 | (23.8) | (06) | 133 | 5/16-18 | 100 | Black | |||||
| C1938-1R* | 2 | 2524) | (23.8 | (2) | (675)1 | (23.8) | (06) | (06) | 133 | 5/16 - 18 | 100 | Red | ||||
| C4044* | 2 | 2524) | (2 | (65.9)1 | (65.9) | (2826 | (3.9) | (23.8 | (06) | 133 | 3/8 -16 | 150 | Black | |||
| C4044-1* | 2 | 2524) | (2) | (65.9) | (65.9) | (3.9) | (23.8 | (06) | (06 | 133) | 3/8 - 16 | 150 | Black | |||
| C4044-1R* | 2 | (524) | (22 | (6.9 | (6.9) | (23.8) | (06) | (06) | 133 | 3/8 -16 | 150 | Red | ||||
| C5898* | 2 | 2524) | (23.8) | (75)1 | (2) | (6751 | (23.8 | 133) | 3/8 - 16 | 150 | Red | |||||
| C6344-2 | 2 | (524) | (22 | (.9 | (65.9) | 123 | None | None | 133 | 1/2 - 20 | 150 | Black | ||||
| C7020* | 2 | (524) | (23.8) | (6751 | (22) | (675)1 | 137.63 | (16) | 133) | 3/8 - 16 | 150 | Red | ||||
| JB3816-2 | 2 | 2542) | (24.9) | (22 | None | (06) | None | 134.9 | 3/8-16 | 150 | Black | |||||
| JB3816-3 | 2 | (540) | (24.9) | (65.9) | (2) | (175)1 | None | (16 | None | 134.9) | 3/8 - 16 | 150 | Red | |||
| C2791* | 3 | 2524 | (17 51 | (4.2)1 | (65.9) | (6) | 133 | 1/4 - 20 | 30 | Thermalestcass | Black | |||||
| C2791-R* | 3 | 2524) | (175)1 | (442) | (65.9) | (175)1 | (175) | (06) | 133 | 1/4 - 20 | 30 | Themelestcss | Red | |||
| C2909* | 3 | 2524) | (17.51 | (442) | (65.9) | (25.4)1 | (1751 | (06) | (06) | 133 | 10-32 | 24 | Thermoalestcss | Black | ||
| C2909-1* | 3 | 2524 | (175) | (442)1 | (65.9) | (25.41 | (3.9) | (675) | 133)1 | 1/4 - 20 | 30 | Black | ||||
| C7018* | 3 | 2524 | (17.5) | (479) | (675) | (3.9) | (53.5) | (016) | (0.6 | 133 | 22 die /4 d | M6 | 55 | Black |
Note:
Commercial vehicle solutions
Power distribution
GB3000Series
Pass-thrudistributionblock
The GB3000 pass-thru distribution blocks allow one ground or power device to meet multiple ground/power requirements, inboth the cab and engine compartment of your vehicle.A gasket is included for ingress protection.Designed to meet all your ground/ power needs,the GB3000 series provides robust connections,eliminates the need to stack cables and reduces associated warranty claims based on affiliated problems.The GB3000 series also provides power distribution suitable formanyfeed thru applications in marine, construction,agriculture,bus,military,RVand specialtyvehicles.
Specifications
·Current:200A maximum
·Temperature rating: -40°F (-40°\mathsf{C}) to 185°\mathsf{F} (85°\mathsf{C})
Torque:M6 stud 50 in-lbs max; M6 mounting 50 in-Ilbs max
·Termination: M6 nuts
Materials:
·Housing:BlackULrated94V-0 thermoplastic
·Cover:Black or red santoprene cover (rated UL 94V-0) for protection from accidental shorts
·Current carrying studs: Zinc-plated brass
·Mounting studs:Stainlesssteel ·Gasket:Black santoprene gasket rated UL 94V-0 ·RoHS Compliant: Yes
Servicableparts:
·Cover:B151-7192 (black),B151-7194-R (red) ·Busbar:B109-7050
Circuit protection
Protection against overcurrent and short circuit in commercial vehicle electrical systems
Eaton'sleadershipincircuitprotectionextendsintocommercialvehicleswithbladeandbolt-on circuitrotectiondevicesincludingavarietyofthermalcircuitbreakerandfusesolutions.Eatn solutions range from low current branch circuit fuses and circuit breakers up through 200 Amp switchablecircuitbreakersthatprotectandcontrolheavyvehicleelectricalsystems.Eatonalso offersarangeofmanualandautomaticbatterydisconnectsinourlineofcommercialvehiclepower managementproducts.
Commercial vehicle solutions
Circuit protection
MINI Blade fuses
Specifications
·Fast acting
·Current rating:2-30A
·Voltagerating:32VDC
·Interrupt rating:1000A @ 32VDC Housing material:UL 94-V0 thermoplastic Terminal material:Silver-plated zinc alloy Temperature rating: -40°F \boldsymbol{-40°C)} to 248°F \angle120°C)
·Marking: Amperage marking is OCR compliant
·Compliances:UL-Listed;SAE J2077;ISO 8820-3;SAE
·J1171 (lgnition protected)
·Consult factory for higher voltage fuses.
Commercial vehicle solutions
Circuit protection
| Part number | Amp rating | Color |
| BK-ATM-2 | 2 | Grey |
| BK-ATM-3 | 3 | Violet |
| BK-ATM-4 | 4 | Pink |
| BK-ATM-5 | 5 | Tan |
| BK-ATM-7.5 | 7.5 | Brown |
| BK-ATM-10 | 10 | Red |
| BK-ATM-15 | 15 | Light Blue |
| BK-ATM-20 | 20 | Yellow |
| BK-ATM-25 | 25 | Natural |
| BK-ATM-30 | 30 | Green |
Commercial vehicle solutions
Circuit protection
Series 21X
Minicircuitbreakers
Specifications
·Auto(Type 1)&modified (Type 2) resetavailable
·SinglePoleThermalTypeBreakers
·Rating:5-30A;14VDC
·Interrupt Rating:150A @ 14VDC (5-10A versions); 225A @ 14VDC(15A version);300A @ 14VDC (20A version); 450A @ 14VDC (25-30A versions)
·Operating Temperature Rating: -40°F (-40°\mathsf{C}) to 185°F (85°\mathsf{C})
·StorageTemperatureRating: -40°F (-40°\mathsf{C}) to 260°F \angle125°C)
·Materials:GreyUL94-V0 thermoplastichousingwithmetal cover:Breakertype indicated by subscript next to amperage rating on end of breaker
·Marking:Standard marking includes amp/voltage ratings, part number, and date code.OCRmarking is available.
·Termination:Compatiblewith 2.8\mathsf{mm} (280)Type fuse blocks using 0.32in. \left(8.1\mathsf{mm}\right) centerline spacing
·Compliances:SAEJ553Type|and Type IlCircuitBreakers
·RoHS compliant
·Anti weld-contacts available
Commercial vehicle solutions
Circuit protection
Temperature derating /Time current curves
Commercial vehicle solutions
Circuit protection
ATCBlade fuses
Specifications
·Fast acting
·Current Rating:1-40A
·VoltageRating:32VDC
·InterruptRating:1000A @ 32VDC
·Housing Material:UL 94-V0rated
Terminal Material:Tin-plated zinc alloy TemperatureRating: -76°F \mathsf{I}-60°\mathsf{C}) to 230°\mathsf{F} 110°C)
·Marking: Amperage marking is OCR compliant. ·Compliances:UL-Recognized (3-40A) available;SAEJ1284;ISO 8820-3; SAE J1171 (lgnition Protection) available,RoHS compliant
Commercial vehicle solutions
Circuit protection
| Part number (Amp) | Fuse body color |
| BK-ATC-1 | Black |
| BK-ATC-2 | Gray |
| BK-ATC-3 | Violet |
| BK-ATC-4 | Pink |
| BK-ATC-5M | Tan |
| BK-ATC-7-1-2M | Brown |
| BK-ATC-10M | Red |
| BK-ATC-15M | Blue |
| BK-ATC-20M | Yellow |
| BK-ATC-25M | Clear |
| BK-ATC-30M | Green |
| BK-ATC-35 | Blue/Green |
| BK-ATC-40 | Orange |
Time current curves
Commercial vehicle solutions
Circuit protection
easyIDTM
Illuminatingbladefuses&fuseholders
Now, a drop-in replacement is available for low-voltage applications up to 100 amps that can benefit from open fuse indication.The Eaton line of easylDTM illuminating blade fuses and holders use Light Emitting Diode (LED) technology to show that a fuse has opened, making them easy to spot infuse panels tucked up under darkdashboards.
Features
The ATM (3-30A),ATC? (3-40A) and Maxi@ (20-100A) cover the most common replacementfuseneeds
lluminating fuse holders with easylDTM use regular ATM and ATC blade fuses and feature a red LED that glows when thefuse opens
The ATM, ATC and MAXI fuses alluse the same universal color-coding as traditional non-illuminating fuses, making it easier to match up an indicating replacement for an open fuse
easylDTMATMIlluminatingbladefuses
Following on thepopularity and wide application of ATMfusesfor late-model OEM vehicles, the easy ID illuminating ATM fuse line is available in popular ATM amp ratings withpackaging that's designed for easyretailselling.
| Part number | Amprating | Color |
| BK-ATM-3ID | 3 | Violet |
| BK-ATM-5ID | 5 | Tan |
| BK-ATM-7-1-2ID | 7.5 | Brown |
| BK-ATM-10ID | 10 | Red |
| BK-ATM-15ID | 15 | Light Blue |
| BK-ATM-20ID | 20 | Yellow |
| BK-ATM-25ID | 25 | Natural |
| BK-ATM-30ID | 30 | Green |
Commercial vehicle solutions
Circuit protection
easylDTMATCIlluminatingbladefuses
Introduced in the late'70s, \mathsf{A T C}^{\otimes} bladefusesarewidelyusedbyautomotiveOEMs. With a large installed base, the Eaton ATC easy IDTM illuminating fuse line has great selling potential with popular ATC amp ratings in packaging that's designed for easy retail selling.
| Part number | Amp rating | Color |
| BK-ATC-3ID | 3 | Violet |
| BK-ATC-5ID | 5 | Tan |
| BK-ATC-7-1-2ID | 7.5 | Brown |
| BK-ATC-10ID | 10 | Red |
| BK-ATC-151ID | 15 | Light Blue |
| BK-ATC-20ID | 20 | Yellow |
| BK-ATC-30ID | 30 | Green |
| BK-ATC-40ID | 40 | Amber |
easylDTMMaxi(MAX)Illuminatingbladefuses
Used for protecting circuits in wiring harnesses (usually found under the hood, in a fuse panel or supplementary panel near the battery) Maxi Fuses are finding increased popularity in domestic cars and some import models.Current OEM applications range up to 60 amps, but some aftermarket accessories (such as high-end stereos)requireprotection up to 80 amps.The Eaton easy ID Maxi illuminating fuse line is a sure seller for the high amp circuit protection market.
easylDTMlluminatingholdersforbladefuses
Now customers have a way to get open fuse indication when adding circuits with easy ID illuminating inline fuse holders for ATM and ATC blade fuses.Attractive blister backs increaseimpulse sales.
| Fuse Type | Part Number | MaxVolts/Amps | Description |
| ATM | ATM-FHID | 32V / 20A | |
| ATC | ATC-FHID | 32V / 20A |
Commercial vehicle solutions
Circuit protection
Series 22X
Circuitbreakers
Specifications
·Auto (Type 1),modified (Type 2) & manufal (Type 3) reset breakers
·SinglePoleThermalTypeBreakers
·Rating:5-30A,14VDC;28VDC (Series 223 & 226).
InterruptRating:150A @ 14VDC (5-10A versions);225A @ 14VDC(15A version);300A @ 14VDC (20A version); 450A @ 14VDC (25-30A versions) Operating TemperatureRating: -40°F (-40°\mathsf{C}) to 185°F (85°\mathsf{C}) :
·Storage TemperatureRating: -40°\mathsf{F} (-40°\mathsf{C}) to 260°\mathsf{F} 125°C)
Materials:UL94-V0 thermoplastic housing with gold metal cover (Type I) orsilvermetal cover(TypeIl&Ill)
·Marking:Standard marking includes amp/voltratings,part number, and date code.Type Ill resetbuttons are color-coded to amperage ratings. Push-to-trip option is available on manual reset version.OCR marking is available.
Termination:Compatible with 280 Type or {\mathsf{A T C}}^{\otimes} fuse blocks.
·Compliances:SAEJ553,SAEJ1171 (ignition protection)
Commercial vehicle solutions
Circuit protection
Temperature derating / Time current curves
Commercial vehicle solutions
Circuit protection
Series 227
ATC Circuitbreakers(lowprofile)
Specifications
·Manual reset
·Single Pole Thermal Type Breakers
·Rating:5-30A,28VDC
·Interrupt Rating: 2000A @ 28VDC Operating Temperature Rating: -40°\mathsf{F}\left(-40°\mathsf{C}\right) to 185°\mathsf{F} (85°\mathsf{C}) Storage Temperature Rating: -40°F (-40°\mathsf{C}) to 260°\mathsf{F}\left(125°\mathsf{C}\right)
Materials:UL 94-V0 thermoplastic body.Tin-plated copper alloy terminals
·Marking: Cover is color-coded to amperage ratings
Termination: 5.2\mathsf{mm} wideblades compatiblewith \mathsf{A T C@} type fuse blocks
·Compliances:SAEJ553;SAEJ1171(ignition protected)
Dimensions in inches (mm)
Commercial vehicle solutions
Circuit protection
Temperaturederating/Time currentcurves
Commercial vehicle solutions
Circuit protection
MAXI Blade fuses
Specifications
·Fast acting
·Current Rating:20-80A
·VoltageRating:32VDC
·Interrupt Rating:1000A @ 32VDC
·Housing Material: UL 94-V0 thermoplastic
Terminal Material:Silver-plated zinc alloy
·Temperature Rating: -40°F e \boldsymbol{-40°C)} to 248°\mathsf{F} *120°\mathsf{C})
·Marking:Amperage marking is OCR compliant
·Compliances:SAEJ1888,ISO 8820-3,SAEJ1171(ignition protected)
Commercial vehicle solutions
Circuit protection
| Part number | Amp rating | Color |
| BK-MAX-20 | 20 | Yellow |
| BK-MAX-30 | 30 | Green |
| BK-MAX-40 | 40 | Orange |
| BK-MAX-50 | 50 | Red |
| BK-MAX-60 | 60 | Blue |
| BK-MAX-70 | 70 | Tan |
| BK-MAX-80 | 80 | Neutral |
Commercial vehicle solutions
Circuit protection
Series 19X
MAXICircuitbreakers
Specifications
·Auto(Type 1),modified(Type 2)&manual (Type3)reset
·SinglePole Thermal Type Breakers
·Rating:8-50A;14VDC;28VDC(Series193,194,&195)
·Interrupt Rating: 150A @ 14VDC (8-10A versions); 225A@ 14VDC (15A version); 300A @ 14VDC (20A version); 450\mathsf{A}@ 14VDC(25-30A versions);600A @ 4VDC (35-40A versions); 750A @ 14VDC (50A version)
·OperatingTemperatureRating: -40°F C -40°\mathsf{C}) to 185°F (85°\mathsf{C})
·Storage Temperature Rating: -40°F (-40°\mathsf{C}) to 260°\mathsf{F} *125°C)
·Materials:Grey UL 94-V0 thermoplastic
·Termination: Compatible with fuse blocks accepting MAX \midB or ATC?blade fuses ·Compliances:SAEJ553,SAE J1171(ignition protected)
Commercial vehicle solutions
Circuit protection
Temperature derating/Time current curves
Commercial vehicle solutions
Circuit protection
Fuse/circuitbreakerinsertion/extractiontool
Specifications
·Getonlythe extractorsyouneed ·Eliminates design changes when protection requirements change ·Easy mounting using simple split-ball snap-lock post ·Tight grip allows devices to be removed and inserted ·High temperature resilient nylon 6/6221°F *105°C)
Series 32013
2.8\mathsf{mm} (mini)fuse and circuit breakerinsertion/extraction tool.Canbe used with Series 32000Dual VehicleElectrical Center.
Features
·Tightgripallowsdevicestoberemoved and inserted ·High temperature resilient nylon6/6 *105°\mathsf{C})
Commercial vehicle solutions
Circuit protection
Series 12X
Shortstopcircuitbreakers
Specifications
·SinglePoleThermalTypeBreakers
·Applications: Battery chargers, trucks,buses,RVs,trolling motors,etc
Rating:5-50A,14VDC;28VDC (Series 123,124,&125)
Interrupt Rating:Main Circuit Protection:1.5kA @ 12VDC(Series 123w/plasticcover);BranchCircuit Protection:2.5kA @ 12VDC(Series 121 & 124-01 sealed& Series 123 w/plastic cover)
Operating Temperature Rating: -40°\mathsf{F} (-40°\mathsf{C}) to 185°F \mathsf{(85°C)}
·Storage Temperature Rating: -40°F (-40°\mathsf{C}) to 260°\mathsf{F} \angle125°C) Materials:BlackUL-Rated thermoplasticbody(thermosetfor Type Ill body & buttons). Cover is grey thermoplasticorsteel-TypeIgold, Type Il silver
·Marking: Custom marking available. Consult factory for options
Termination:#10-32threadand quick-connectoptionsavailable
Torque Rating:24in-lbs (2.7N\bullet\mathsf{m}) max
MountingTorqueRating: Plastic cover - 15 in-lbs (1.7N ·m); Metal cover-30 in-lbs (3.4\mathsf{N}\bullet\mathsf{m})
IngressProtectionRating:IP66On plastic coverversiononly (exceptforterminals)
·Compliances:SAEJ553;SAEJ1171 (ignition protected)
Dimensions in inches (mm)
Commercial vehicle solutions
Circuit protection
\*\*\*30Amaximum Please consult factory regarding configuration availability.
Temperature derating / Time current curves
Commercial vehicle solutions
Circuit protection
Series25XMid-Rangecircuitbreakers
Specifications
·Auto (Type 1), Modified (Type 2) & Manual (Type3)breakersavailable
·SinglePoleThermalTypeBreakers
·Applications:Thisunit isexternal ignitionprotected andweatherproof. It is typically used in DC power systemsinmarine applications (asa mainorbranchcircuitbreaker), truck,bus and RV systems,add-on protectionforaccessories,etc
·Rating:10-50A,32VDC
·Interrupt Rating: Circuit Protection (2.5mathsf{k A}) per ABYC E-11
· Operating Temperature Rating: -40°F (-40°\mathsf{C}) to \boldsymbol{185°\mathsf{F}} 185°C)
·StorageTemperatureRating: -40°F (-40°\mathsf{C}) to 260°\mathsf{F} 125°C)
·Materials:BlackUL94-V0thermose plasticbody.Cover,lever,and button are UL Rated 94V0 thermoplastic. Coverhasablack thermoplastic elastomerovermold
·Marking: Standard marking includes amp/volt ratings,part numbers, and "SAE Type B"
Termination:#10-32Threadedstuds
TorqueRating:24in-lbs (2.7N\bullet\mathsf{m}) max
·MountingTorqueRating:Panel mountwitheither#8-32threaded inserts or \#10 clearance holes. 18 in-lbs (2.0N\bullet\mathsf{m}) max
·IngressProtectionRating:IP66
·Features/Options:Series 254\&255 have a uniquereset mechanismwhich providesavisual indicationof tripped condition.Series255alsofeatures a push-to-trip option
·Compliances:SAE J553;ABYC E-11; SAE J1171 (ignition protected)
Dimensions in inches (mm)
251 SERIES
254 SERIES
Commercial vehicle solutions
Circuit protection
Commercial vehicle solutions
Circuit protection
Commercial vehicle solutions
Circuit protection
Series 18X Hi-Amp circuit breaker
Specifications
·Auto (Type 1), Modified (Type 2) & Manual(Type 3)breakers available
·SinglePoleThermalTypeBreakers
·Applications:Typicallyused in auxiliary andaccessory circuitsintruck, bus'RVs and marine systems.Others includebatterychargersandDCaudio systems. Series 181, \boldsymbol{184}\& 185 are sealedforenginecompartmentand bilge area applications.
·Rating:25-150A,30VDC;42VDCNom (Series 184&185)
·Interrupt Rating:3000A @ 30VDC
·OperatingTemperatureRating: -40°F (-40°\mathsf{C}) to 185°F (85°\mathsf{C})
·StorageTemperatureRating: -30°F (-34°\mathsf{C}) to 300°\mathsf{F} A 149°C)
Materials:BlackUL94-V0 thermosetplastic.Thermoplastic elastomerstudinsulatorsareprovided on covered units withF-style (surface-mount)bases
·Marking:Standardmarkingincludes ampratings and part numbers. Custom markings also available.
·Termination:1/4-28threadedstuds
·Torque Rating: 50 in-lbs (5.6N\bullet\mathsf{m}) max
·Mounting Torque Rating:Panel or surface-mount options; 50 in-lbs (5.6N\bullet\mathsf{m}) max.Threaded insert option has a max torque of 25 in-lbs (2.8N\bullet\mathsf{m}) :
·IngressProtectionRating:IP67
·Features/Options:Series 184\&185 haveauniqueresetmechanismwhich provides visual indication of tripped condition.Series185 alsofeatures a push-to-trip option
Dimensions in inches (mm)
FIREWALL MOUNT
PANEL MOUNT
Commercial vehicle solutions
Circuit protection
Temperaturederating/Time currentcurves
Commercial vehicle solutions
Circuit protection
Series187Marineratedcircuitbreaker(MRCB)
Specifications
·Manual (Type 3) breakers available
·SinglePoleThermal TypeBreakers
·Applications:Typically used in DC powersystemsinmarineapplications (as a main or branch circuit breaker), truck and bus systems,RV systems, add-onprotectionforaccessories, lift gates,etc.This unit is external ignitionprotected andweatherproof.
·Rating:25-200A,48VDC
·InterruptRating:MainBreaker ProtectionInterruptRating (5,000\mathsf{A}@ 14VDC, 3,000\mathsf{A@} 28VDCand {1,500\mathsf{A}\ @} 48VDC).
·Operating Temperature Rating: -40°F (-40°\mathsf{C}) to 185°F 185°C)
StorageTemperature Rating: -40°F (-40°\mathsf{C}) to 260°F 1 125°C)
·Materials:Black UL 94-V0 thermoset plasticbody.Cover and leverare UL 94-V0 thermoplastic
·Marking: Standard marking includes amp/volt ratings.Custom markings also available
Termination:5/16-18threadedstuds
·Torque Rating:75in-lbs (8.5N\bullet\mathsf{m}) max
·MountingTorqueRating:Panelor surface-mount options;50in-lbs (5.6\ N\bullet\mathsf{m}) max
IngressProtectionRating:IP66
Features/Options:Amanualreset circuitbreakerwithOn-Offswitch capability
·Compliances:ABYC E-11; CE; SAE J1171 (ignition protected)