Disconnect Encl.
Free-Standing Enclosures
Disconnect Ordering Information
General Electric †
TDA † Disconnects
* Do not install disconnects in this height enclosure.
The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed.
Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the
applicable regulations, codes and standards.
General Electric† Fuse Clip Rating Fuse Enclosure Height
Mechanism Amp Class 72 84 90 C D
for Switches Amp Volt A B AB A B
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
NC 30A (non) (non) -- 11.87 301 10.50 267 17.37 441 16.00 406 20.37 517 19.00 483 4.75 121 6.25 159
TDOM1A 30A (non) (non) -- 11.87 301 12.37 314 17.37 441 17.87 45 20.37 517 20.87 530 7.00 178 5.50 140
TDOM1A 30A 30A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 7.00 178 5.50 140
TDOM1B 30A 30A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM1B 30A 60A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM1B 30A 60A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM1A 60A (non) (non) -- 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 7.00 178 5.50 140
TDOM1B 60A 60A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM1B 60A 60A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM1B 60A 100A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM1B 60A 100A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM1A 100A (non) (non) -- 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 7.00 178 5.50 140
TDOM1B 100A 100A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM1B 100A 100A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM1B 100A 200A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM1B 100A 200A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 20.37 517 20.87 530 11.50 292 5.50 140
TDOM2 200A (non) (non) -- 11.87 301 9.75 248 17.37 441 15.25 387 20.37 517 18.25 464 7.00 178 9.25 235
TDOM2 200A 200A 250V H,R 11.87 301 9.75 248 17.37 441 15.25 387 20.37 517 18.25 464 15.50 394 9.25 235
TDOM2 200A 200A 600V H,R 11.87 301 9.75 248 17.37 441 15.25 387 20.37 517 18.25 464 15.50 394 9.25 235
General Electric† Enclosure Height
Mechanism for Amp Circuit Breaker Type 72 84 90 C D
Circuit Breakers ABAB AB
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
TDOM1A 150A TEB,TEC,TED,THED 11.87 301 11.25 286 17.37 441 16.75 425 20.37 517 19.75 502 7.00 178 5.50 140
TDOM1B 150A TB1,TEC,TECL 11.87 301 11.25 286 17.37 441 16.75 425 20.37 517 19.75 502 11.50 292 5.50 140
TDOM1C 150A TEL 11.87 301 11.25 286 17.37 441 16.75 425 20.37 517 19.75 502 7.00 178 5.50 140
TDOM1D 150A THCL1 11.87 301 9.87 251 17.37 441 15.37 390 20.37 517 18.37 467 7.00 178 5.50 140
TDOM3 225A TFJ,TFK,THFK,TFL 11.87 301 10.87 276 17.37 441 16.37 416 20.35 517 19.37 492 10.50 267 6.00 152
TDOM4 400A TJJ,TJK4,THJK4,TJL4V 11.87 301 10.00 254 17.37 441 15.50 394 20.35 517 18.50 470 8.25 210 9.50 241
TDOM4 600A TJK6,THJK6,TJ4V,TJL4V 11.87 301 10.00 254 17.37 441 15.50 394 20.35 517 18.50 470 8.25 210 9.50 241
TDOM5 400A TB4,TJH6S 11.87 301 10.00 254 17.37 441 15.50 394 20.35 517 18.50 470 14.25 362 9.50 241
TDOM6 225A TLB2,THLC2 * * ** 17.37 441 14.87 378 20.37 517 17.87 454 11.75 298 9.50 241
TDOM6 400A TLB4,THLC4 * * ** 17.37 441 13.50 343 20.37 517 16.50 419 11.75 298 9.50 241
TDOM6 800A TKMA,THKMA,TK4V * * * * ** * * 20.37 517 17.87 454 11.75 298 9.50 241
TDOM6 1200A TK4V,THK4V * * * * ** * * 20.37 517 17.87 454 11.75 298 9.50 241
TDOM7 600A TB6 * * ** 17.37 * 11.75 298 20.37 517 14.75 375 18.25 464 9.50 241
TDOM7 800A TB8 * * ** 17.37 * 11.75 298 20.37 517 14.75 375 18.25 464 9.50 241
TDOM7 1200A TKL12S * * * * ** * * 20.37 517 14.75 375 18.25 464 9.50 241
† Marks are the property of their respective owners.
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
335 B-Line series electrical enclosures Eaton
Disconnect Enclosures
I-T-E† Circuit Enclosure Height
Encl. Mechanism for Cable Amp Breaker Device A C(1) D(2)
Depth Circuit Breakers Length Frame Height 72 84 90 nom min max min max
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
FHOE036 36 125A ED 6.37 162 11.87 301 17.37 441 20.37 517 5.37 136 -2.75 -70 13.50 343 3.00 76 9.75 248
FHOE036 36 125A CED 9.62 244 11.87 301 17.37 441 20.37 517 8.50 216 .06 2 16.87 428 3.00 76 9.75 248
FHOF036 36 250A FD 9.50 241 11.87 301 17.37 441 20.37 517 5.62 143 2.43 62 13.87 352 4.50 114 8.50 216
18 FHOF036 36 250A CFD 14.12 359 11.87 301 17.37 441 20.37 517 10.25 260 7.25 184 18.62 473 4.50 114 8.50 216
FHOJ036 36 400A, 600A JD, LD 11.00 279 11.87 301 17.37 441 20.37 517 5.25 133 -2.87 -73 13.43 341 7.50 191 10.12 257
FHOJ036 36 400A, 600A CJD 17.87 454 11.87 301 17.37 441 20.37 517 12.12 308 4.12 105 20.37 517 7.50 191 10.12 257
FHOE036 36 125A ED 6.37 162 11.87 301 17.37 441 20.37 517 5.37 136 1.37 35 10.75 273 3.00 76 6.37 162
FHOE036 36 125A CED 9.62 244 11.87 301 17.37 441 20.37 517 8.50 216 4.62 117 14.00 356 3.00 76 6.37 162
FHOF036 36 250A FD 9.50 241 11.87 301 17.37 441 20.37 517 5.62 143 1.62 41 11.00 356 4.50 114 5.50 140
20 FHOF036 36 250A CFD 14.12 359 11.87 301 17.37 441 20.37 517 10.25 260 6.43 163 15.87 403 4.50 114 5.50 140
FHOJ036 36 400A, 600A JD, LD 11.00 279 11.87 301 17.37 441 20.37 517 5.25 133 0.00 0 10.62 270 7.50 191 7.25 184
FHOJ036 36 400A, 600A CJD 17.87 454 11.87 301 17.37 441 20.37 517 12.12 308 6.93 176 17.50 445 7.50 191 7.25 184
* 48 125A ED 6.37 162 11.87 301 17.37 441 20.37 517 5.37 136 -15.37 -390 26.25 667 3.00 76 24.43 621
* 48 125A CED 9.62 244 11.87 301 17.37 441 20.37 517 8.50 216 -12.00 -305 29.50 749 3.00 76 24.43 621
* 48 250A FD 9.50 241 11.87 301 17.37 441 20.37 517 5.62 143 -15.00 -381 26.50 673 4.50 114 23.00 584
18 * 48 250A CFD 14.12 359 11.87 301 17.37 441 20.37 517 10.25 260 -10.25 -260 30.37 771 4.50 114 23.00 584
* 48 400A, 600A JD, LD 11.00 279 11.87 301 17.37 441 20.37 517 5.25 133 -15.43 -393 26.12 663 7.50 191 24.50 622
* 48 400A, 600A CJD 17.87 454 11.87 301 17.37 441 20.37 517 12.12 308 -8.50 -216 33.00 838 7.50 191 24.50 622
FHON048 48 800A, 1200A MD, ND 16.00 406 11.87 301 17.37 441 20.37 517 8.12 206 -5.12 -130 21.43 544 9.00 229 20.50 521
* 48 125A ED 6.37 162 11.87 301 17.37 441 20.37 517 5.37 136 -14.87 -378 25.25 641 3.00 76 23.43 595
* 48 125A CED 9.62 244 11.87 301 17.37 441 20.37 517 8.50 216 -11.50 -292 28.50 724 3.00 76 23.43 595
* 48 250A FD 9.50 241 11.87 301 17.37 441 20.37 517 5.62 143 -14.50 -368 25.50 648 4.50 114 22.00 559
20 * 48 250A CFD 14.12 359 11.87 301 17.37 441 20.37 517 10.25 260 -9.75 -248 30.37 771 4.50 114 22.00 559
* 48 400A, 600A JD, LD 11.00 279 11.87 301 17.37 441 20.37 517 5.25 133 -14.93 -379 25.12 638 7.50 191 23.62 600
* 48 400A, 600A CJD 17.87 454 11.87 301 17.37 441 20.37 517 12.12 308 -8.00 -203 32.00 813 7.50 191 23.62 600
FHON048 48 800A 1200A MD, ND 16.00 406 11.87 301 17.37 441 20.37 517 8.12 206 -5.12 -130 20.93 532 9.00 229 21.00 533
* 48 125A ED 6.37 162 11.87 301 17.37 441 20.37 517 5.37 136 -13.37 -340 23.25 591 3.00 76 20.62 524
* 48 125A CED 9.62 244 11.87 301 17.37 441 20.37 517 8.50 216 -10.00 -254 26.50 673 3.00 76 20.62 524
* 48 250A FD 9.50 241 11.87 301 17.37 441 20.37 517 5.62 143 -13.00 -330 23.50 597 4.50 114 19.37 492
24 * 48 250A CFD 14.12 359 11.87 301 17.37 441 20.37 517 10.25 260 -8.25 -210 28.37 721 4.50 114 19.37 492
* 48 400A, 600A JD, LD 11.00 279 11.87 301 17.37 441 20.37 517 5.25 133 -13.43 -341 23.12 587 7.50 191 20.93 532
* 48 400A, 600A CJD 17.87 454 11.87 301 17.37 441 20.37 517 12.12 308 -6.50 -165 30.00 762 7.50 191 20.93 532
FHON048 48 800A, 1200A MD,ND 26.00 406 11.87 301 17.37 441 20.37 517 8.12 206 -3.12 -79 19.93 506 9.00 229 20.50 521
Disconnect Encl.
Free-Standing Enclosures
Disconnect Ordering Information
I-T-E Siemens® †
Disconnect Cable Circuit Breaker Types Mechanism Length
FHOE036 36 ED2 ,ED4, ED6, HED4, HED6, ED6ETI
FHOE036 36 CED6, CED6ETI
FHOF036 36 FD6, FXD6, HFD6, FXD6ETI
FHOF036 36 CFD6, CFD6ETI
FHOJ036 36 JD2, JD6, JXD6, HJD6, JXD6ETI, LD6,LXD6, HLD6, LXD6ETI, SHJD6, SLD6, SHLD6
FHOJ036 36 CJD6, CJD6ETI, CLD6, CLD6ETI,SCJD6,SCLD6
FHON048 48 MD6, HMD6, CMD6, MXD6ETI, CMD6ETI, SMD6, SHMD6, SCMD6, ND6, HND6,CND6,SND6,SCND6
MAX-FLEX † Disconnect Mechanism
I-T-E SIEMENS † MAX-FLEX † Disconnect Mechanism
* Non-standard mechanism with 48 inch operating cable must be specified.
(1) Flexible operating cable allows disconnect to be mounted within min and max of “C” dimension when “D” is minimum.
(2) Flexible operating cable allows disconnect to be mounted within min and max of “D” dimension when “C” is nominal
The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to
be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe
operation and compliance with the applicable regulations, codes and standards.
Notes: Flexible cable allows for variable disconnect mounting and adequate wire bending space must be maintained.
Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
† Marks are the property of their respective owners.
336 Eaton B-Line series electrical enclosures
Disconnect Enclosures
Disconnect Encl.
Free-Standing Enclosures
Disconnect Ordering Information
Square D® †
Square D† Fuse Clip Rating Fuse Enclosure Height
Mechanism Amp Class 72 84 90 C D
for Switches Amp Volt A B A B AB
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
RC-1 30A (non) (non) -- 11.87 301 11.75 298 17.37 441 17.18 436 20.37 517 20.18 513 3.25 83 7.25 184
RC-2 30A 30A 250V H,K,R 11.87 301 11.75 298 17.37 441 17.18 436 20.37 517 20.18 513 5.00 127 7.25 184
RC-3 30A 30A 600V H,K,R 11.87 301 11.75 298 17.37 441 17.18 436 20.37 517 20.18 513 8.00 203 7.25 184
RC-3 30A 30A 600V J 11.87 301 11.75 298 17.37 441 17.18 436 20.37 517 20.18 513 5.00 127 7.25 184
RC-3 30A 60A 250V H,K,R 11.87 301 11.75 298 17.37 441 17.18 436 20.37 517 20.18 513 6.00 152 7.25 184
TC-1 30A (non) (non) -- 11.87 301 9.87 251 17.37 441 15.37 390 20.37 517 18.37 467 5.75 146 6.25 159
TC-2 30A 30A 250V H,K,R 11.87 301 9.87 251 17.37 441 15.37 390 20.37 517 18.37 467 5.75 146 6.25 159
TC-3 30A 30A 600V H,K,R 11.87 301 9.87 251 17.37 441 15.37 390 20.37 517 18.37 467 7.75 197 6.25 159
TC-3 30A 30A 600V J 11.87 301 9.87 251 17.37 441 15.37 390 20.37 517 18.37 467 5.75 146 6.25 159
TC-3 30A 60A 250V H,K,R 11.87 301 9.87 251 17.37 441 15.37 390 20.37 517 18.37 467 6.00 152 6.25 159
TD-1 60A (non) (non) -- 11.87 301 10.75 273 17.37 441 16.25 413 20.37 517 19.25 489 6.50 165 6.75 171
TD-2 60A 30A 600V H,K,R 11.87 301 10.75 273 17.37 441 16.25 413 20.37 517 19.25 489 8.50 216 6.75 171
TD-2 60A 60A 250V H,K,R 11.87 301 10.75 273 17.37 441 16.25 413 20.37 517 19.25 489 6.50 165 6.75 171
TD-3 60A 60A 600V H,K,R 11.87 301 10.75 273 17.37 441 16.25 413 20.37 517 19.25 489 9.00 229 6.75 171
TD-3 60A 60A 600V J 11.87 301 10.75 273 17.37 441 16.25 413 20.37 517 19.25 489 6.50 165 6.75 171
TE-1 100A (non) (non) -- 11.87 301 10.50 273 17.37 441 16.00 406 20.37 517 19.00 483 4.75 121 8.50 216
TE-2 100A 100A 250V H,K,R 11.87 301 10.50 273 17.37 441 16.00 406 20.37 517 19.00 483 7.50 191 8.50 216
TE-2 100A 100A 600V H,K,R 11.87 301 10.50 273 17.37 441 16.00 406 20.37 517 19.00 483 9.50 241 8.50 216
TE-2 100A 100A 600V J 11.87 301 10.50 273 17.37 441 16.00 406 20.37 517 19.00 483 6.25 159 8.50 216
TE-3 100A 200A 600V J 11.87 301 10.50 273 17.37 441 16.00 406 20.37 517 19.00 483 13.75 349 8.50 216
TF-1 200A (non) (non) -- 11.87 301 9.12 232 17.37 441 14.62 371 20.37 517 17.62 448 5.50 140 11.75 298
TF-2 200A 200A 250V H,K,R 11.87 301 9.12 232 17.37 441 14.62 371 20.37 517 17.62 448 11.50 292 11.75 298
TF-2 200A 200A 600V H,K,R 11.87 301 9.12 232 17.37 441 14.62 371 20.37 517 17.62 448 14.00 356 11.75 298
TF-2 200A 200A 600V J 11.87 301 9.12 232 17.37 441 14.62 371 20.37 517 17.62 448 10.25 260 11.75 28
TF-3 200A 400A 600V J 11.87 301 9.12 232 17.37 441 14.62 371 20.37 517 17.62 448 14.50 368 11.75 298
Square D† Enclosure Height
Mechanism for Amp Circuit Breaker Type 72 84 90 C D
Circuit Breakers A B A B AB
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
RN-1 100A FAL,FHL,FCL 7.87 200 6.87 174 17.37 441 16.37 416 20.37 517 19.37 492 5.25 133 5.50 140
RP-1 250A KAL,KHL,KCL 7.87 200 6.62 168 17.37 441 17.12 435 20.37 517 20.12 511 7.25 184 5.75 146
RR-1 400A LAL,LHL,Q4L * * ** 17.37 441 12.75 324 20.37 517 15.75 400 7.75 197 9.00 229
RR-2 400A ILL * * ** 17.37 441 17.12 435 20.37 517 20.12 511 11.00 279 15.75 400
RT-1 800A MEL * * ** 17.37 441 12.62 321 20.37 517 15.62 397 9.25 235 12.00 305
RT-1 1000A MAL,MHL * * ** 17.37 441 12.62 321 20.37 517 16.62 422 9.25 235 12.00 305
9422 Disconnect Mechanism
* Do not install disconnects in this height enclosure.
The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed.
Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the
applicable regulations, codes and standards.
† Marks are the property of their respective owners.
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
337 B-Line series electrical enclosures Eaton
Disconnect Enclosures
Disconnect Encl.
Free-Standing Enclosures
Disconnect Ordering Information
ALLEN-BRADLEY †
Standard enclosures designed to accept variable depth
type 1494V / 1494U.
Allen-Bradley† 1494V / 1494U disconnect switch:
1.Disconnect switch.
2.Operating mechanism.
3.Operating handle.
4.Fuse block kit, (if required).
5.Fuse clip kit, (if required).
6.Line and Load connectors, (if necessary).
7.Connecting rod.
Allen-Bradley† 1494V 1494U circuit breaker:
1.Circuit breaker.
2.Operating mechanism.
3.Operating handle.
4.Line and load connectors, (if necessary).
5.Connecting rod.
NOTE: Standard enclosures designed to accept fixed
depth type 1494F or 1494D.
Allen-Bradley† 1494F disconnect switch:
1.Disconnect switch.
2.Operating mechanism.
3.Operating handle.
4.Fuse block kit, (if required).
5.Fuse clip kit, (if required).
6.Line and load connectors, (if necessary).
Allen-Bradley† 1494D circuit breaker:
1.Circuit breaker.
2.Operating mechanism.
3.Operating handle.
4.Line and load connectors, (if necessary).
5.Slide mechanism
CUTLER-HAMMER †
Standard enclosures designed to accept variable depth
type C361 or C371.
Cutler-Hammer† C361 disconnect switch:
1.Disconnect switch.
2.Operating mechanism.
3.Operating handle.
4.Fuse clip kit, (if required).
5.Line and load connectors, (if necessary) .
NOTE: Items 1, 2 and 3 can be ordered as an assembly.
Cutler-Hammer† C371 circuit breaker:
1.Circuit breaker.
2.Operating mechanism.
3.Operating handle.
4.Line and load connectors, (if necessary).
NOTE: Items 2 and 3 can be ordered as an assembly.
GENERAL ELECTRIC †
Standard enclosures designed to accept variable depth
type TDA.
General Electric† TDA disconnect switch:
1.Disconnect switch, (QMR, QMW).
2.Operating mechanism.
3.Operating handle TDA1.
4.Fuse clip kit or no-fuse kit, (if required).
5.Line and load connectors, (if necessary).
6.Extended length drive rod, ( if required).
NOTE:These items can be ordered as an assembly.
General Electric† TDA circuit breaker:
1.Circuit breaker.
2.Operating mechanism.
3.Operating handle TDA1.
4.Line and load connectors, (if necessary).
5.Extended length drive rods, (if required).
I-T-E SIEMENS †
Standard enclosures designed to accept Max-Flex†
type FHO.
I-T-E† Max-Flex† circuit breaker:
1.Circuit breaker.
2.Operating mechanism.
3.Operating handle.
4.Line and load connectors, (if necessary).
5.Operating cable.
NOTE: Items 2, 3 and 5 can be ordered as an assembly,
standard with a 36 inch long operating cable. All 24
inch deep enclosures require a 48 inch long cable.
Notes: Data subject to change without notice.
† Marks are the property of their respective owners.
338 Eaton B-Line series electrical enclosures
Disconnect Enclosures
Disconnect Encl.
Free-Standing Enclosures
Disconnect Ordering Information
SQUARE D †
Standard enclosures designed to accept variable depth
type 9422.
Square D† 9422 disconnect switch:
1. Disconnect switch.
2. Operating mechanism.
3. Operating handle.
4. Fuse clip kit, (if required).
5. Line and load connectors, (if necessary).
6. Connecting rod.
Square D† 9422 circuit breaker:
1. Circuit Breaker.
2. Operating mechanism.
3. Operating handle.
4. Line and load connectors, (if necessary).
5. Connecting rod.
When ordering flange-mounted disconnect equipment be sure to
include all necessary components.
1. Enclosure includes the following equipment:
Enclosure door locking handle and rods
Door interlocking system
Interlocking connecting rod
Adjustable bracket, (see note 3)
2. Operator adapter plate, gasket and hardware for the type of
disconnect device being used MUST be ordered separately
(see page 451)
3. 24 inch deep enclosures include an adjustable bracket for
mounting some disconnects:
Cutler-Hammer† C361 device
Cutler-Hammer† C371 E and F devices unless long connecting
rod C371CS1 is specified
Cutlet-Hammer† C371 G and K devices unless long connecting
rod C371CS2 is specified
General Electric† TDA device unless extended length rod
TDSR is specified.
Square D† 9422 device unless extra long connecting rod
9422-R2 is specified.
4. Disconnects and related components are available from the
manufacturer.
5. The disconnect ordering information provided is derived from
information supplied be the manufacturer of the equipment
to be installed. Fit and function of all equipment should be
checked before and after installation to assure proper and
safe operation and compliance with the applicable
regulations, codes and standards.
Important Note
Notes: Data subject to change without notice.
† Marks are the property of their respective owners.
339 B-Line series electrical enclosures Eaton
Disconnect Enclosures
Disconnect Encl.
340 Eaton B-Line series electrical enclosures
Disconnect Enclosures
Operator Enclosures
Operator Enclosures
Pushbutton Enclosures Type 12 and Type 4X - 22.5 mm & 30.5 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342-343
Pushbutton Enclosures Type 12 and Type 4X Extra-Deep - 30.5 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . 344-345
Pushbutton Enclosures Type 12 Miniature - 22.5 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346-347
Pushbutton Enclosures Type 12 Hinge Cover - 30.5 mm with Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348-349
Pushbutton Enclosures Type 12 Angle Front - 30.5 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350-351
Pushbutton Enclosures Hole & Cutout Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352
Consolet Type 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353-355
Console Type 12 - AW-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 356-357
Console Type 12 - AW-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358-360
Console Type 12 - AW-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361-365
Console Accessories Type 12 - AW-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366-367
Console Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368-369
341 B-Line series electrical enclosures Eaton
Pushbutton Enclosures
Type 12 & Type 4X - 22.5 mm & 30.5 mm
Data and Illustration Sheet
Finish
• Wash and phosphate undercoat
• ANSI 61 gray polyester powder finish
• Stainless steel enclosure cover and sides of body have a
smooth brushed finish
Accessories
• Hole seals
• Columns and bases
• Touch-up paint
• See accessories section
Construction
• Enclosure and cover are fabricated from (14) or (16) gauge steel,
Type 304 or Type 316L stainless steel
• All continuous welded seams are finished smooth
• Cover is attached with captive screws which thread into sealed
well nuts (stainless enclosures use stainless sealed well nuts)
• Cover has concealed, detachable hinges which allow for quick
removal and can be hinged on either side (not offered on all
sizes)
• Cover has a fixed, oil-resistant gasket
• Weldnut in body of enclosure for grounding
• Cover is pre-punched with standard 30.5 mm or miniature
22.5 mm “4-way” pushbutton holes
• External mounting feet are provided for secure wall mounting
Discount Schedule: C2
Subclass: DP0
Application
• Designed to mount standard 30.5 mm or miniature
22.5 mm oil-tight pushbuttons, pilot lights and switches
• Protects against circulating dust, falling dirt and
dripping non-corrosive liquids
Standards
• UL 508A listed, Type 12, Type 13, and Type 4X
• CSA C22.2 No.94 certified, Type 12, Type 13, and
Type 4X
• Conforms to NEMA standard for Type 12, Type 13,
and Type 4X
.672
(17)
(TYP)
1.203 D
(30.5)
.190 (TYP)
(5)
Standard 4-Way
.484
(12)
(TYP) .886 D
(22.5)
.125 (TYP)
(3)
Miniature 4-Way
Operator Enclosures
Operator Enclosures
PBxx Series PVxSS Series
Notes: We can provide special sizes, finishes and other holes and cutouts, see page 352. Consult the factory for your special requirements.
342 Eaton B-Line series electrical enclosures
Pushbutton Enclosures
Type 12 & Type 4X - 22.5 mm & 30.5 mm
Illustration Sheet and Catalog Number
* Enclosures are not hinged.
† PB1 and PB2 enclosures are fabricated from (16) gauge steel or stainless steel
detachable hinge
C
Section X-X
Front View
B
B-.88
(22)
A-.50
(13)
B-.50
(13)
X
X
2.25
(57)
(TYP)
2.25
(57)
(TYP)
D
E mounting
feet
∅ .218 x .281
(6 x 7)
A
A+.50
(13)
PB1
PB3
PB2
PB4
PB6 PB9
PB12 PB16
PB20 PB25
Cover Hole
Layout
Enclosure Catalog Number Enclosure Size
(30.5 mm Hole) (22.5 mm Hole) Holes Height x Width x Depth D E
Type 304 Type 316L Type 304 A x B x C
Steel Stainless Stainless Steel Stainless in. mm in. mm in. mm
PB1*† PB1SS*† PB1SS6*† PB1M*† PB1MSS*† 1 4.00 x 3.25 x 3.00 102 x 83 x 76 2.12 54 1.75 44
PB2*† PB2SS*† PB2SS6*† PB2M*† PB2MSS*† 2 5.75 x 3.25 x 3.00 146 x 83 x 76 2.12 54 1.75 44
PB3 - --- 3 7.25 x 6.25 x 3.00 184 x 159 x 76 2.62 67 2.12 54
PB4 - --- 4 7.25 x 6.25 x 3.00 184 x 159 x 76 2.62 67 2.12 54
PB6 PB6SS* PB6SS6* - - 6 9.50 x 6.25 x 3.00 241 x 159 x 76 2.62 67 2.12 54
PB9 PB9SS* PB9SS6* - - 9 9.50 x 8.50 x 3.00 241 x 216 x 76 2.62 67 2.12 54
PB12 PB12SS* PB12SS6* - - 12 11.75 x 8.50 x 3.00 298 x 216 x 76 2.62 67 2.12 54
PB16 - --- 16 11.75 x 10.75 x 3.00 298 x 273 x 76 2.62 67 2.12 54
PB20 - --- 20 14.00 x 10.75 x 3.00 356 x 273 x 76 2.62 67 2.12 54
PB25 - --- 25 14.00 x 13.00 x 3.00 356 x 330 x 76 2.62 67 2.12 54
PV3* PV3SS* PV3SS6* PV3M* PV3MSS* 3 8.00 x 3.25 x 2.75 203 x 83 x 70 2.12 54 1.75 44
PV4* PV4SS* PV4SS6* PV4M* PV4MSS* 4 10.25 x 3.25 x 2.75 260 x 83 x 70 1.87 47 1.75 44
PV5* - --- 5 12.50 x 3.25 x 2.75 318 x 83 x 70 1.87 47 1.75 44
PV6* - --- 6 14.75 x 3.25 x 2.75 375 x 83 x 70 1.87 47 1.75 44
PV8* - --- 8 20.25 x 3.25 x 2.75 514 x 83 x 70 1.87 47 1.75 44
PV10* - --- 10 24.75 x 3.25 x 2.75 629 x 83 x 70 1.87 47 1.75 44
PV3 PV4
PV5 PV6
PV8 PV10 D
1.75
(44)
3.25
(83)
2.25
(57)
(TYP)
PV Series
Typical 8 & 10
Hole
A-1.50
(38)
B-.50
(13)
Operator Enclosures
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
343 B-Line series electrical enclosures Eaton
Pushbutton Enclosures
Type 12 & Type 4X Extra-Deep - 30.5 mm
Data and Illustration Sheet
Finish
• Wash and phosphate undercoat
• ANSI 61 gray polyester powder finish
• Stainless steel enclosure cover and sides of body have a smooth
brushed finish
Accessories
• Hole seals
• Columns and bases
• Touch-up paint
• See accessories section
Construction
• Enclosure and cover are fabricated from (14) or (16) gauge steel or
Type 304 stainless steel
• Enclosure has extra depth for those components that
require more room
• All continuous welded seams are finished smooth
• Cover is attached with captive screws which thread into sealed
well nuts (stainless enclosures use stainless sealed well nuts)
• Cover has concealed, detachable hinges which allow for quick
removal and can be hinged on either side (PBX Series only)
• Cover has a fixed, oil-resistant gasket
• Weldnut in body of enclosure for grounding
• Cover is prepunched with standard 30.5 mm “4-way” pushbutton
holes
• External mounting feet are provided for secure wall mounting
Discount Schedule: C2
Subclass: DP0
Application
• Designed to mount standard 30.5 mm oil-tight
pushbuttons, pilot lights and switches
• Protects against circulating dust, falling dirt and
dripping non-corrosive liquids
Standards
• UL 508A listed, Type 12, Type 13, and Type 4X
• CSA C22.2 No.94 certified, Type 12, Type 13, and
Type 4X
• Conforms to NEMA standard for Type 12, Type 13,
and Type 4X
.672
(17)
(TYP)
1.203 D
(30.5)
.190 (TYP)
(5)
Standard 4-Way
Operator Enclosures
Operator Enclosures
Notes: We can provide special sizes, finishes and other holes and cutouts, see page 352. Consult the factory for your special requirements.
344 Eaton B-Line series electrical enclosures
Pushbutton Enclosures
Type 12 & Type 4X Extra-Deep - 30.5 mm
Illustration Sheet and Catalog Number
PBX4
PBX9
PBX6
PBX10
PBX12 PBX16
PBX20 PBX25
PBX30
PBX36
B
B-.88
(22)
X
X
2.25
(57)
(TYP)
2.25
(57)
(TYP)
D
E mounting feet
A A+.50
(13)
detachable hinge
C
Section X-X
Cover Hole
Layout
Enclosure Enclosure Size
Catalog Number Holes Height x Width x Depth
Type 304 A x B x C D E
Steel Stainless in. mm in. mm in. mm
PVX1*† PVX1SS*† 1 4.00 x 4.00 x 4.75 102 x 102 x 121 2.12 54 1.75 44
PVX2*† PVX2SS*† 2 6.00 x 4.00 x 4.75 152 x 102 x 121 2.12 54 1.75 44
PVX3* PVX3SS* 3 8.00 x 4.00 x 4.75 203 x 102 x 121 2.12 54 1.75 44
PVX4* PVX4SS* 4 10.00 x 4.00 x 4.75 254 x 102 x 121 1.87 47 1.75 44
PBX4 - 4 7.25 x 6.25 x 4.75 184 x 159 x 121 2.62 67 2.12 54
PBX6 - 6 9.50 x 6.25 x 4.75 241 x 159 x 121 2.62 67 2.12 54
PBX9 - 9 9.50 x 8.50x x 4.75 241 x 216 x 121 2.62 67 2.12 54
PBX10 - 10 14.00 x 6.25 x 4.75 356 x 159 x 121 2.62 67 2.12 54
PBX12 - 12 11.75 x 8.50 x 4.75 298 x 216 x 121 2.62 67 2.12 54
PBX16 - 16 11.75 x 10.75 x 4.75 298 x 273 x 121 2.62 67 2.12 54
PBX20 - 20 14.00 x 10.75 x 4.75 356 x 273 x 121 2.62 67 2.12 54
PBX25 - 25 14.00 x 13.00 x 4.75 356 x 330 x 121 2.62 67 2.12 54
PBX30 - 30 16.25 x 13.00 x 4.75 413 x 330 x 121 2.62 67 2.12 54
PBX36 - 36 16.25 x 15.25 x 4.75 413 x 387 x 121 2.62 67 2.12 54
* Enclosures are not hinged.
† PVX1 and PVX2 enclosures are fabricated from (16) gauge steel or stainless steel.
PVX1 PVX2
PVX3 PVX4
A-.50
(13)
B-.50
(13)
∅ .218 x .281
(6 x 7)
Operator Enclosures
Front View
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
345 B-Line series electrical enclosures Eaton
Pushbutton Enclosures
Type 12 Miniature - 22.5 mm
Data and Illustration Sheet
Finish
• Wash and phosphate undercoat
• ANSI 61 gray polyester powder finish
Accessories
• Hole seals
• Columns and bases
• Touch-up paint
• See accessories section
Construction
• Enclosure and cover are fabricated from (14) or (16) gauge steel
• All continuous welded seams are finished smooth
• Cover is attached with captive screws which thread into
sealed well nuts
• Covers more than 2.75 inches wide have concealed,
detachable hinges which allow for quick removal and can
be hinged on either side
• Cover has a fixed oil-resistant gasket
• Weldnut in body of enclosure for grounding
• Cover is pre-punched with miniature 22.5 mm “4-way”
pushbutton holes
• External mounting feet are provided for secure wall mounting
Discount Schedule: C2
Subclass: DP0
Application
• Designed to mount miniature 22.5 mm oil-tight
pushbuttons, pilot lights and switches
• Protects against circulating dust, falling dirt and
dripping non-corrosive liquids
Standards
• UL 508A listed, Type 12 and Type 13
• CSA C22.2 No.94 certified, Type 12 and Type 13
• Conforms to NEMA standard for Type 12 and Type 13
.484
(12)
(TYP) .886 D
(22.5)
.125 (TYP)
(3)
Miniature 4-Way
Operator Enclosures
Operator Enclosures
Notes: We can provide special sizes, finishes and other holes and cutouts, see page 352. Consult the factory for your special requirements.
346 Eaton B-Line series electrical enclosures
Pushbutton Enclosures
Type 12 Miniature - 22.5 mm
Illustration Sheet and Catalog Number
* Enclosures are not hinged.
† PB1B and PB2B enclosures are fabricated from (16) gauge steel
B
B-.88
(22)
X
X
1.87
(47)
(TYP)
1.50
(38)
(TYP)
D
E mounting feet
A
A+.50
(13)
detachable hinge
C
PB1B
PBS3B
PB2B
PBS4B
PB4B PB6B
PB9B PB12B
PB16B
PB20B
PB25B
PB30B
Section X-X
Cover Hole
Layout
Enclosure Enclosure Size
Catalog Number Holes Height x Width x Depth
A x B x C D E
in. mm in. mm in. mm
PB1B*† 1 3.25 x 2.75 x 3.50 83 x 70 x 89 1.75 44 1.50 38
PB2B*† 2 5.12 x 2.75 x 3.50 130 x 70 x 89 1.75 44 1.50 38
PBS3B* 3 7.00 x 2.75 x 3.50 178 x 70 x 89 1.75 44 1.50 38
PBS4B* 4 8.87 x 2.75 x 3.50 225 x 70 x 89 1.75 44 1.50 38
PB4B 4 6.62 x 5.00 x 3.50 168 x 127 x 89 2.50 64 1.87 47
PB6B 6 8.50 x 5.00 x 4.25 216 x 127 x 108 2.50 64 1.87 47
PB9B 9 8.50 x 6.50 x 4.25 216 x 165 x 108 2.50 64 1.87 47
PB12B 12 10.37 x 6.50 x 4.25 263 x 165 x 108 2.50 64 1.87 47
PB16B 16 10.37 x 8.00 x 4.25 263 x 203 x 108 2.50 64 1.87 47
PB20B 20 12.25 x 8.00 x 4.25 311 x 203 x 108 2.50 64 1.87 47
PB25B 25 12.25 x 9.50 x 4.25 311 x 241 x 108 2.50 64 1.87 47
PB30B 30 14.12 x 9.50 x 4.25 359 x 241 x 108 2.50 64 1.87 47
A-.50
(13)
B-.50
(13)
∅ .218 x .281
(6 x 7)
Operator Enclosures
Front View
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
347 B-Line series electrical enclosures Eaton
Pushbutton Enclosures
Type 12 Hinge Cover - 30.5 mm With Panel
Data and Illustration Sheet
Finish
• Wash and phosphate undercoat
• ANSI 61 gray polyester powder finish
• Panels have white enamel finish
Accessories
• Hole seals
• Columns and bases
• Touch-up paint
• See accessories section
Construction
• Enclosure and cover are fabricated from (14) gauge steel
• All continuous welded seams are finished smooth
• Cover is secured to the body with a continuous hinge on one
side and captive screws which thread into sealed well nuts on
the opposite side
• Cover has a fixed oil-resistant gasket
• Weldnut in body of enclosure for grounding
• Cover is pre-punched with standard 30.5 mm “4-way”
pushbutton holes
• Heavy gauge panel mounted to weldnuts is provided with
enclosure
• External mounting feet are provided for secure wall mounting
Discount Schedule: C2
Subclass: DP0
Application
• Designed to mount standard 30.5 mm oil-tight
pushbuttons, pilot lights and switches
• Protects against circulating dust, falling dirt and
dripping non-corrosive liquid
Standards
• UL 508A listed, Type 12 and Type 13
• CSA C22.2 No.94 certified, Type 12 and Type 13
• Conforms to NEMA standard for Type 12 and Type 13
.672
(17)
(TYP)
1.203 D
(30.5)
.190 (TYP)
(5)
Standard 4-Way
Operator Enclosures
Operator Enclosures
Notes: We can provide special sizes, finishes and other holes and cutouts, see page 352. Consult the factory for your special requirements.
348 Eaton B-Line series electrical enclosures
Pushbutton Enclosures
Type 12 Hinge Cover - 30.5 mm With Panel
Illustration Sheet and Catalog Number
B
B-.88
(22)
X X
2.50
(64)
(TYP)
3.12
(79)
2.62
(67)
.50
(13)
5.875
(149)
2.50
(64)
(TYP)
mounting feet
A
A+.50
(13)
continuous hinge
removable panel
C
PBP4 PBP6 PBP9
PBP12 PBP16
PBP20 PBP25
PBP30
PBP36
PBP42
Section X-X
Cover Hole
Layout
Enclosure Enclosure Size Panel Size
Catalog Number Holes Height x Width x Depth
A x B x C Height x Width
in. mm in. mm in. mm
PBP4 4 8.50 x 7.50 x 6.00 216 x 191 x 152 6.50 35 5.50 140
PBP6 6 11.00 x 7.50 x 6.00 279 x 191 x 152 9.00 229 5.50 140
PBP9 9 11.00 x 10.00 x 6.00 279 x 254 x 152 9.00 229 8.00 203
PBP12 12 13.50 x 10.00 x 6.00 343 x 254 x 152 11.50 292 8.00 203
PBP16 16 13.50 x 12.50 x 6.00 343 x 318 x 152 11.50 292 10.50 267
PBP20 20 16.00 x 12.50 x 6.00 406 x 318 x 152 14.00 356 10.50 267
PBP25 25 16.00 x 15.00 x 6.00 406 x 381 x 152 14.00 356 13.00 330
PBP30 30 18.50 x 15.00 x 6.00 470 x 381 x 152 16.50 419 13.00 330
PBP36 36 18.50 x 17.50 x 6.00 470 x 445 x 152 16.50 419 15.50 394
PBP42 42 21.00 x 17.50 x 6.00 533 x 445 x 152 19.00 483 15.50 394
A-1.50
(38)
B-.50
(13)
∅ .218 x .281
(6 x 7)
Operator Enclosures
Front View
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
349 B-Line series electrical enclosures Eaton
Pushbutton Enclosures
Type 12 Angle Front - 30.5 mm
Data and Illustration Sheet
Finish
• Wash and phosphate undercoat
• ANSI 61 gray polyester powder finish
Accessories
• Hole seals
• Columns and bases
• Touch-up paint
• See accessories section
Construction
• Enclosure and cover are fabricated from (14) or (16) gauge steel
• All continuous welded seams are finished smooth
• Cover is attached with captive screws which thread into sealed
well nuts
• Covers more than 3.25 inches high have concealed, detachable
hinges which allow for quick removal and can be hinged on
either side
• Cover has a fixed oil-resistant gasket
• Weld nut in body of enclosure for grounding
• Cover is pre-punched with standard 30.5 mm “4-way”
pushbutton holes
• External mounting feet are provided for secure wall mounting
Discount Schedule: C2
Subclass: DP0
Application
• Designed to mount standard 30.5 mm oil-tight
pushbuttons, pilot lights and switches
• Designed with angle front for mounting in either
30° or 60° positions
• Protects against circulating dust, falling dirt and
dripping non-corrosive liquid
Standards
• UL 508A listed, Type 12 and Type 13
• CSA C22.2 No.94 certified, Type 12 and Type 13
• Conforms to NEMA standard for Type 12 and Type 13
.672
(17)
(TYP)
1.203 D
(30.5)
.190 (TYP)
(5)
Standard 4-Way
Operator Enclosures
Operator Enclosures
Notes: We can provide special sizes, finishes and other holes and cutouts, see page 352. Consult the factory for your special requirements.
350 Eaton B-Line series electrical enclosures
Pushbutton Enclosures
Type 12 Angle Front - 30.5 mm
Illustration Sheet and Catalog Number
B C
E
F
D D+.50
(13)
B-.88
(22)
X
X
2.50
2.25 (64)
(57)
(TYP)
2.25
(57)
(TYP)
mounting feet
.218 x .281
(6 x 7)
A
detachable
hinge
PBC2 PBCS3
PBC3 PBCS4
PBC4 PBC6
PBC8 PBC9
PBCS12
PBC12
PBC16
PBC20
PBC25
Side Section View
Front Cover View
Section X-X
Cover Hole
Layout
Enclosure Enclosure Size
Catalog Number Holes Height x Width x Depth
A x B x C DEF
in. mm in. mm in. mm in. mm
PBC2*† 2 3.25 x 6.25 x 4.81 83 x 159 x 122 3.31 84 1.75 44 2.12 54
PBCS3* 3 3.25 x 8.50 x 4.81 83 x 216 x 122 3.31 84 1.75 44 2.12 54
PBC3 3 6.25 x 7.25 x 6.37 159 x 184 x 162 5.90 150 2.12 54 2.62 67
PBCS4* 4 3.25 x 10.25 x 4.81 83 x 260 x 122 3.31 84 1.75 44 1.87 47
PBC4 4 6.25 x 7.25 x 6.37 159 x 184 x 162 5.90 150 2.12 54 2.62 67
PBC6 6 6.25 x 9.50 x 6.37 159 x 241 x 162 5.90 150 2.12 54 2.62 67
PBC8 8 6.25 x 11.75 x 6.37 159 x 298 x 162 5.90 150 2.12 54 2.62 67
PBC9 9 9.50 x 8.50 x 7.88 241 x 216 x 200 8.84 225 2.12 54 2.62 67
PBCS12 12 6.25 x 16.25 x 6.37 159 x 413 x 162 5.90 150 2.12 54 2.62 67
PBC12 12 8.50 x 11.75 x 7.50 216 x 298 x 191 7.84 199 2.12 54 2.62 67
PBC16 16 10.75 x 11.75 x 8.62 273 x 298 x 219 9.78 248 2.12 54 2.62 67
PBC20 20 10.75 x 14.00 x 8.62 273 x 356 x 219 9.78 248 2.12 54 2.62 67
PBC25 25 13.00 x 14.00 x 9.75 330 x 356 x 248 11.75 298 2.12 54 2.62 67
* Enclosures are not hinged.
† PBC2 enclosures are fabricated from (16) gauge steel
A-1.50
(38)
B-.50
(13)
∅ .25 x .375
(6 x 10)
Operator Enclosures
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
351 B-Line series electrical enclosures Eaton
Pushbutton Enclosures Hole and Cutout Information
Illustration Sheet
Standard 4-Way (Type S4-WAY)
Our standard 4-way pushbutton hole will accommodate
all standard size pushbutton, pilot lights and selector
switches. The hole is designed to orient the device and
legend plate in one of four different positions.
Furnished on “PB”, “PBX”, “PBP”, “PBC”, “PBCS”,
“PV”, “PVX”, “PVS” and “P” style enclosures.
Miniature 4-Way (Type: M4-WAY)
Our miniature 4-way pushbutton hole will accommodate
miniature size pushbuttons, pilot lights and selector
switches. The hole is designed to orient the device and
legend plate in one of four different positions.
Furnished on “PB-M” and “PB-B” style enclosures.
.672
(Typ)
(17)
1.203 D
(30.5)
.190 (TYP)
(5)
.672
(17)
1.210 D
(30.5)
1.210 D
(30.5)
.190
(5)
.600
(15)
1.210 D
(30.5)
.136 D
(3)
.750
(19)
2.00
(51)
2.00
(51)
60°
.484
(Typ)
(12)
.886 D
(22.5)
.125 (TYP)
(3)
Type: C-101 Type C-102
Type C-201 Type: C-103
Custom Holes and Cutouts
Operator Enclosures
Operator Enclosures
Notes: When specifying hole types “C-101”, “C-102” and “C-103” indicate orientation of “key”. Dimensions are in inches.
Millimeters shown are for reference only. Data subject to change without notice.
352 Eaton B-Line series electrical enclosures
Operator Enclosures
Consolet
Type 12
Data Sheet
Accessories
• Columns and bases
• Touch-up paint
• See Accessories section
Construction
• Enclosure and cover are fabricated from (14) gauge steel or
Type 304 stainless steel
• All continuous welded seams are finished smooth
• Cover is secured to the body with a continuous hinge on one
side and captive screws which thread into sealed well nuts on
the opposite side
• Cover has a fixed oil-resistant gasket
• Ground stud provided on cover and body
Discount Schedule: C2
Subclass: DQ0
Application
• Houses electrical controls and instruments
• Designed with angle front for mounting in either
30° or 60° position
• Protects against circulating dust, falling dirt and
dripping non-corrosive liquids
Standards
• UL 508A listed, Type 12 and Type 13
• CSA C22.2 No.94 certified, Type 12 and Type 13
• Conforms to NEMA standard for Type 12 and Type 13
Finish
• Wash and phosphate undercoat
• ANSI 61 gray polyester powder finish
• Stainless steel enclosure cover and sides of body
have a smooth brushed finish
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
353 B-Line series electrical enclosures Eaton
Operator Enclosures
Consolet
Type 12
Illustration Sheet and Catalog Number
Enclosure Enclosure Size
Catalog Number Height x Width x Depth
Type 304 A x B x C DE F GH J
Steel Stainless in. mm in. mm in. mm in. mm in. mm in. mm in. mm
AC-8C8 AC-8C8SS 8.00 x 8.00 x 7.12 203 x 203 x 181 5.62 143 7.50 191 6.62 168 7.37 187 8.25 210 8.25 210
AC-8C12 AC-8C12SS 8.00 x 12.00 x 7.12 203 x 305 x 181 5.62 143 7.50 191 6.62 168 11.37 289 8.25 210 12.25 311
AC-8C16 AC-8C16SS 8.00 x 16.00 x 7.12 203 x 406 x 181 5.62 143 7.50 191 6.62 168 15.37 390 8.25 210 16.25 413
AC-8C20 AC-8C20SS 8.00 x 20.00 x 7.12 203 x 508 x 181 5.62 143 7.50 191 6.62 168 19.37 492 8.25 210 20.25 514
AC-12C12 AC-12C12SS 12.00 x 12.00 x 9.12 305 x 305 x 232 7.62 194 11.00 279 10.62 270 11.37 289 12.25 311 12.25 311
AC-12C16 AC-12C16SS 12.00 x 16.00 x 9.12 305 x 406 x 232 7.62 194 11.00 279 10.62 270 15.37 390 12.25 311 16.25 413
AC-12C20 AC-12C20SS 12.00 x 20.00 x 9.12 305 x 508 x 232 7.62 194 11.00 279 10.62 270 19.37 492 12.25 311 20.25 514
AC-12C24 AC-12C24SS 12.00 x 24.00 x 9.12 305 x 610 x 232 7.62 194 11.00 279 10.62 270 23.37 594 12.25 311 24.25 616
AC-16C16 AC-16C16SS 16.00 x 16.00 x 11.12 406 x 406 x 282 9.62 244 14.50 368 14.62 371 15.37 390 16.25 413 16.25 413
AC-16C20 AC-16C20SS 16.00 x 20.00 x 11.12 406 x 508 x 282 9.62 244 14.50 368 14.62 371 19.37 492 16.25 413 20.25 514
AC-16C24 AC-16C24SS 16.00 x 24.00 x 11.12 406 x 610 x 282 9.62 244 14.50 368 14.62 371 23.37 594 16.25 413 24.25 616
AC-16C30 AC-16C30SS 16.00 x 30.00 x 11.12 406 x 762 x 282 9.62 244 14.50 368 14.62 371 29.37 746 16.25 413 30.25 768
AC-16C36 AC-16C36SS 16.00 x 36.00 x 11.12 406 x 914 x 282 9.62 244 14.50 368 14.62 371 35.37 898 16.25 413 36.25 921
AC-20C20 AC-20C20SS 20.00 x 20.00 x 13.12 508 x 508 x 333 11.62 295 18.00 457 18.62 473 18.62 473 20.25 514 20.25 514
AC-20C24 AC-20C24SS 20.00 x 24.00 x 13.12 508 x 610 x 333 11.62 295 18.00 457 18.62 473 22.62 574 20.25 514 24.25 616
AC-20C30 AC-20C30SS 20.00 x 30.00 x 13.12 508 x 762 x 333 11.62 295 18.00 457 18.62 473 28.62 727 20.25 514 30.25 768
captive screw
captive screw
continuous hinge
continuous hinge
30˚
60˚
Typical Mounting Configurations
Side Views
Operator Enclosures
Notes: We can provide special sizes, finishes and other holes and cutouts, see page 352. Consult the factory for your special requirements.
354 Eaton B-Line series electrical enclosures
Operator Enclosures
Consolet
Type 12
Illustration Sheet
H
J
F
G
B
E
A
2.50
(64)
F-1.50
(38)
G-.50
(13)
X
X
D
C
Section X-X
Front Cover View Enclosure Opening View
(cover and hinge removed)
Side Section View
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
355 B-Line series electrical enclosures Eaton
Operator Enclosures
Console
Type 12 - AW-9
Data Sheet and Catalog Number
Consoles Console Size Back Panel Panel Size Side Panel Panel Size
Height x Width x Depth Height x Width Height x Width
A x B x C D A x B A x B
Catalog Number in. mm in. mm Catalog Number in. mm Catalog Number in. mm
AC-924B 48.00 x 24.00 x 18.00 1219 x 610 x 457 15.25 387 AW3020P 26.87 x 16.87 682 x 428 AW3020P 26.87 x 16.87 682 x 428
AC-936B 48.00 x 36.00 x 18.00 1219 x 914 x 457 25.25 641 AW3030P 26.87 x 26.87 682 x 682 AW3020P 26.87 x 16.87 682 x 428
Construction
• Console, panel cover and door are fabricated from (14)
gauge steel
• All continuous welded seams are finished smooth
• Panel cover is secured to the body with a continuous
hinge along the front side and captive screws which thread
into sealed well nuts on the other three sides
• Cover stops allow the panel cover to be held in the
open position
• Front access door is secured to the body with a heavy-duty
continuous hinge on one side and a 3-point locking handle
which latches to the opposite side
• Print pocket provided
• Panel cover and front door have a fixed oil-resistant gasket
• .375-16 collar studs are provided on back and both side walls
for mounting optional panel
Finish
• Wash and phosphate undercoat
• ANSI 61 gray polyester powder finish
Accessories
• Panels
• NEMA treminal strap kit
• Terminal blocks
• Caster kit
• Touch-up paint
• Replacement handle, 25228C, see page 426
• See Accessories section
Discount Schedule: C2
Subclass: DR0
Application
• Houses electrical controls and instruments
• Designed with 45° angle top surface for
pushbuttons, pilot lights, switches, or other
monitoring devices
• Protects against circulating dust, falling dirt and
dripping non-corrosive liquids
Standards
• UL 508A listed, Type 12
• CSA C22.2 No.94 certified, Type 12
• Conforms to NEMA standard for Type 12
Notes: We can provide special sizes, finishes and other modifications. Consult the factory for your special requirements.
Operator Enclosures
356 Eaton B-Line series electrical enclosures
Operator Enclosures
Console
Type 12 - AW-9
Illustration Sheet
B
A
32.00
(813)
2.00
(51)
25.25
(641)
25.25
(641)
15.25
(387)
C
B-2.75
(70)
19.87
(505)
D
Front View
Front Section View Panel Cover Opening
(Panel Cover Removed)
Side View
.375-16
collar stud
rotation
captive screw
continuous hinge
3-point
handle lock
panel cover
print pocket
(supplied)
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
357 B-Line series electrical enclosures Eaton
Operator Enclosures
Console
Type 12 - AW-12
Data Sheet and Catalog Number
Finish
• Wash and phosphate undercoat
• ANSI 61 gray polyester powder finish
• Optional top assembly and writing desk have an ANSI 61
gray polyester powder finish
• Panels have a white enamel finish
Accessories
• Terminal blocks
• Caster kit
• Touch-up paint
• See Accessories section
• Replacement handle, 25228C, see page 426
Construction
• Console body, panel cover and door, top assembly and
writing desk are fabricated from (14) gauge steel
• All continuous welded seams are finished smooth
• Panel cover is secured to the body with a continuous
hinge along the front side and captive screws which thread
into sealed well nuts on the other three sides
• Cover stops allow the panel cover to be held in the
open position
• Consoles 36 inches wide or less have a single front access
door with a heavy-duty continuous hinge on one side and
3-pt locking handle on the opposite side
• Consoles wider than 36 inches have double front access
doors with heavy-duty continuous hinge and center locating
3-point locking handle which closes right side door over left
• Print pocket provided
• Panel cover, front door and top assembly covers have a
fixed oil-resistant gasket
• Removable panel mounted on .375-16 collar studs is
located behind the console body door
• Optional top assembly has a front-mounted instrument
panel cover and rear-mounted access panel cover
• Optional writing desk is available for convenient
front mounting
Discount Schedule: C2
Subclass: DR0
Console Body Console Body Size Panel Size Top Assembly Writing Desk
Height x Width x Depth Optional Optional
A x B x C Height x Width
Catalog Number in. mm in. mm Catalog Number Catalog Number
AC-1224B 36.00 x 24.00 x 24.00 914 x 610 x 610 26.87 x 16.87 682 x 428 AC-1224T AC-1224W*
AC-1236B 36.00 x 36.00 x 24.00 914 x 914 x 610 26.87 x 26.87 682 x 682 AC-1236T AC-1236W*
AC-1248B 36.00 x 48.00 x 24.00 914 x 1219 x 610 26.87 x 38.87 682 x 987 AC-1248T AC-1248W*
Application
• Houses electrical controls and instruments
• Designed with an angled top and front surface for
pushbuttons, pilot lights, switches or other
monitoring devices
• Protects against circulating dust, falling dirt and
dripping non-corrosive liquids
Standards
• UL 508A listed, Type 12
• CSA C22.2 No.94 certified, Type 12
• Conforms to NEMA standard for Type 12
Notes: We can provide special sizes, finishes and other modifications. Consult the factory for your special requirements.
* Not UL or CSA listed
Operator Enclosures
358 Eaton B-Line series electrical enclosures
Operator Enclosures
Console
Type 12 - AW-12
Illustration Sheet
B
panel cover
panel cover
captive screw
captive screw
continuous hinge
continuous hinge
print pocket
(supplied)
print pocket
(supplied)
body stiffener
body stiffener
rotation
rotation
terminal block
channel
terminal block
channel
panel
panel
3-point
handle lock
3-point
handle lock
A
32.00
(813)
C
10.00
(254)
10.00
(254)
20.00
(508)
20.00
(508)
B
C
A
32.00
(813)
Console Body Front View
(24 inch & 36 inch wide body)
Console Body Front View
(48 inch wide body)
Side View
Side View
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
359 B-Line series electrical enclosures Eaton
Operator Enclosures
Console
Type 12 - AW-12
Illustration Sheet
B
B
20.00
(508)
6.00
(152)
10.00
(254)
10.00
(254)
B-2.75
(70) 11.25
(286)
captive screw access cover
instrument
panel cover
top assembly
console body
writing desk
Top Assembly
Front View
Typical Assembly
Side View
Writing Desk Side View
Front View
(*not UL or CSA listed)
Panel Cover Opening
(panel cover removed)
Operator Enclosures
360 Eaton B-Line series electrical enclosures
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
Console
Type 12 - AW-14
Data Sheet
Construction
• Console body, panel cover and door, top assembly and
writing desk are fabricated from (14) gauge steel
• All continuous welded seams are finished smooth
• Panel cover is secured to the body with a continuous hinge
along the front side and captive screws which thread into
sealed well nuts on the other three sides
• Cover stops allow the panel cover to be held in the
open position
• Consoles 36 inches wide or less have a single front and
rear access door with a heavy-duty continuous hinge on
one side and a 3-point locking handle on the opposite side
• Consoles wider than 36 inches have double front and rear
access doors with a heavy-duty continuous hinge and a
center locating 3-point locking handle which closes right
side door over left
• Mounting channels are welded inside for locating optional
panel along console depth
• Front door has a print pocket
• Panel cover, front door and top assembly covers have
fixed oil-resistant gaskets
• Optional top assembly has front mounted instrument
panel cover(s) and rear mounted access panel cover(s)
• An optional writing desk is available with convenient
front mounting
Finish
• Wash and phosphate undercoat
• ANSI 61 gray polyester powder finish
• Optional top assembly and writing desk have an
ANSI 61 gray polyester powder finish
Accessories
• NEMA terminal strap kit
• Terminal blocks
• Swing panels
• Full and half panels
• Channel mounting hardware
• Caster kit
• Touch-up paint
• Replacement handle, 25228C, see page 426
• See Accessories section
Discount Schedule: C2
Subclass: DR0
Application
• Houses electrical controls and instruments
• Designed with a 60° angle top surface for pushbuttons,
pilot lights, switches or other monitoring devices
• Protects against circulating dust, falling dirt and
dripping non-corrosive liquids
Standards
• UL 508A listed, Type 12
• CSA C22.2 No.94 certified, Type 12
• Conforms to NEMA standard for Type 12
Notes: We can provide special sizes, finishes and other modifications. Consult the factory for your special requirements
Operator Enclosures
361 B-Line series electrical enclosures Eaton
Operator Enclosures
Console
Type 12 - AW-14
Illustration Sheet and
Catalog Number
B
panel cover
captive screw
mounting
channel
continuous hinge
print pocket
(supplied)
rotation
rotation
2.75
(70)
18.00
(457)
3-point
handle
lock
A
32.00
(813)
12.50
(318)
19.25
(489)
19.25
(489)
6.75
(171)
2.75
(70)
B-1.62
(41)
B-2.75
(70) B-2.75
(70)
3.37
(86)
C
A-4.75
(121)
Console Body
Front View
(24 inch & 36 inch wide body)
Console Body
Rear View
Panel Cover Opening
(panel cover removed)
Side View
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Console Body Console Body Size Top Assembly Writing Desk
Height x Width x Depth Optional Optional
A x B x C
Catalog Number in. mm Catalog Number Catalog Number
AC-1424B 50.00 x 24.00 x 23.00 1270 x 610 x 584 AC-1424T AC-1424W*
AC-1436B 50.00 x 36.00 x 23.00 1270 x 914 x 584 AC-1436T AC-1436W*
AC-1448B 50.00 x 48.00 x 23.00 1270 x 1219 x 584 AC-1448T AC-1448W*
AC-1460B 50.00 x 60.00x 23.00 1270 x 1524 x 584 AC-1460T AC-1460W*
AC-1472B 50.00 x 72.00 x 23.00 1270 x 1829 x 584 AC-1472T AC-1472W*
* Not UL or CSA listed
Operator Enclosures
362 Eaton B-Line series electrical enclosures
Operator Enclosures
Console
Type 12 - AW-14
Illustration Sheet
Console Body
Rear View
Panel Cover Opening
(panel cover removed)
B
panel cover
captive
screw
mounting
channel
continuous hinge
print pocket
(supplied)
rotation
rotation
3-point
handle lock
A
C Console Body
Front View
(48 inch wide body) Side View
2.75
(70)
2.75
(70)
12.50
(318)
19.25
(489)
19.25
(489)
6.75
(171)
32.00
(813)
18.00
(457)
B-2.75
(70)
B-2.75
(70)
A-4.75
(121)
B-1.62
(41)
3.37
(86)
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
363 B-Line series electrical enclosures Eaton
Operator Enclosures
Console
Type 12 - AW-14
Illustration Sheet
Console Body Rear View
Panel Cover Opening
(panel cover removed)
B
panel cover
captive
screw
mounting
channel
continuous hinge
print pocket
(supplied)
rotation
rotation
3-point
handle lock
A
C
B/2-2.75
(70)
B/2-2.75
(70)
Console Body Front View
(60 inch & 70 inch wide body)
Side View
2.75
(70)
2.75
(70)
12.50
(318)
19.25
(489)
19.25
(489)
6.75
(171)
32.00
(813)
18.00
(457)
B-2.75
(70)
A-4.75
(121)
B-1.62
(41)
3.37
(86)
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
364 Eaton B-Line series electrical enclosures
Operator Enclosures
Console
Type 12 - AW-14
Illustration Sheet
B
16.00
(406)
access
cover
B
B
B 10.00
(254)
instrument
panel cover
captive
screw
12.50
(318)
Top Assy Front View
(24 inch (610 mm) & 36 inch
(914 mm) wide body)
Top Assy Front View
(48 inch (1219 mm) wide body)
Top Assy Front View
(60 inch (1524 mm) & 72 inch (1829
mm) wide body)
Writing Desk Front View
(* not UL or CSA listed)
Side View
(typical all top assy)
Side View
Top Assy Rear View
(24 inch (610 mm) & 36 inch
(914 mm) wide body)
Top Assy Rear View
(48 inch (1219 mm) wide body)
Top Assy Rear View
(60 inch (1524 mm) & 72 inch
(1829 mm) wide body)
16.00
(406)
16.00
(406)
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
365 B-Line series electrical enclosures Eaton
Operator Enclosures
Console Accessories
Type 12 - AW-14 Discount Schedule: C2
Full and Half Panel Subclass: DR0
Illustration Sheet and Catalog Number
Full panel and half panel for consoles are (12) gauge steel and furnished with panel brackets and all hardware necessary for
channel and panel mounting. Half panels can be mounted in either the upper or lower portion of the console. Console body
design permits the panel to adjust along the depth of the enclosure. Full panel and half panel can be mounted back-to-back.
B
B
B-1.62
(41)
B-1.62
(41)
38.50
(978)
A
A
A
Full Panel Mounting
Full Panel
Half Panel
(upper mount)
Half Panel
(lower mount)
Half Panel Mounting
panel
side bracket
(see detail
sheet page
368)
Half Panel
Panel Panel Size Fits
Height x Width Console Body
A x B
Catalog Number in. mm Catalog Number
AC-1424HP 20.87 x 19.87 530 x 505 AC-1424B
AC-1436HP 20.87 x 31.87 530 x 809 AC-1436B
AC-1448HP 20.87 x 43.87 530 x 1114 AC-1448B
AC-1460HP 20.87 x 55.87 530 x 1419 AC-1460B
19.25
(489)
19.25
(489)
19.25
(489)
19.25
(489)
Full Panel
Panel Panel Size Fits
Height x Width Console Body
A x B
Catalog Number in. mm Catalog Number
AC-1424P 40.12 x 19.87 1019 x 505 AC-1424B
AC-1436P 40.12 x 31.87 1019 x 809 AC-1436B
AC-1448P 40.12 x 43.87 1019 x 1114 AC-1448B
AC-1460P 40.12 x 55.87 1019 x 1419 AC-1460B
AC-1472P 40.12 x 67.87 1019 x 1724 AC-1472B
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
366 Eaton B-Line series electrical enclosures
Operator Enclosures
Console Accessories
Type 12 - AW-14 Discount Schedule: C2
Swing Panel and Terminal Strap Kit Subclass: DR0
Illustration Sheet and Catalog Number
Swing Panel
Panel Panel Size Fits Console Body
Height x Width
A x B
Catalog Number in. mm Catalog Number
AC-1424SWP 40.12 x 18.75 1019 x 476 AC-1424B
AC-1436SWP 40.12 x 30.75 1019 x 781 AC-1436B
Terminal Strap Kit
Panel Quantity Fits Console Body
Catalog Number of Straps Catalog Number
24TS20 4 All AW-14 Series
24TS24 5 All AW-14 Series
Swing Panel Mounting
Swing Panel for Consoles are (12) gauge
steel, have a dual hinge swing panel bracket
and are furnished with panel brackets and all
hardware necessary for channel and panel
mounting. Panels can be installed such that
they hinge either on the left side or right side.
Console body design permits the panel to
adjust along the depth of the enclosure.
The dual hinge allows the inner panel to
swing completely out of the rear opening
when within 5.50 inches. Panel and swing
panel can be mounted back-to-back.
B 2.06
(52)
3.18
(81)
A
Swing Panel Mounting
Swing Panel
Terminal Strap Kit
Terminal Strap Mounting
panel
side bracket
(see detail
sheet page
368)
swing panel
bracket assembly
(see detail sheet)
hinge
Terminal Strap Mounting
Terminal Strap Kits assemble conveniently to
the channel on either side of the console
body. Channel mounting hardware should
be purchased separately for installation. Full
length straps are furnished with adequate
space for the users’ terminal blocks or
terminal blocks and extra straps can be
purchased separately (see detail sheet and
the Accessories section).
19.25
(489)
19.25
(489)
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
367 B-Line series electrical enclosures Eaton
Operator Enclosures
Console Accessories Discount Schedule: C2
Type 12 - AW-14 Subclass: DR0
Illustration Sheet and Catalog Number
Catalog Number Description Fits Illustration Quantity
Console Body
AFSBRKT1 Panel mounting bracket AW-14 Series 1 1
AFCMH3 Channel mounting hardware AW-14 Series 2 3
FTB3005 #18-#8 medium-duty flat base terminal block AW-14 Series 3 1
FTE3001 Medium-duty flat base terminal block end AW-14 Series 3 1
CTB3005 #18-#8 medium-duty channel terminal block AW-12 Series 4 1
CTE3001 Medium-duty channel terminal block end AW-12 Series 4 1
FT6005 #18-#4 heavy-duty flat base terminal block AW-14 Series 3 1
FE6001 Heavy-duty flat base terminal block end AW-14 Series 3 1
CT6005 #18-#4 heavy-duty channel terminal block AW-12 Series 4 1
CE6001 Heavy-duty channel terminal block end AW-12 Series 4 1
CTC2 Channel clamp AW-12 Series 4 1
25012A Channel Strip (72 inch) AW-12 Series - 1
Individual terminal block, end, and clamps only. Heavy and
Medium-duty blocks can be stacked to any length. When
stacked, each block is approximately .43 or .56 inches long,
depending on which block is used. For detail and specific
quantity packages, refer to the Accessories section.
Individual terminal block and terminal end only. Heavy and
Medium-duty blocks can be stacked to any length. When
stocked, each block is approximately .43 or .56 inches long,
depending on which block is used. For detail and specific
quantity packages, refer to the Accessories section.
channel
spring nut
panel nut
panel mounting
stud
terminal end
Top Assembly
Writing Desk
Console
Body
terminal end
channel clamp
channel
clamp
channel terminal block
flat base
terminal block
flat base terminal
block (shown stacked)
side bracket
channel
spring nut
channel
mounting
hardware
channel
mounting
hardware
Illustration 1 Illustration 2
Illustration 3
Illustration 4
channel terminal
block (shown
stacked)
Typical Assembly
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
368 Eaton B-Line series electrical enclosures
Operator Enclosures
Console Details
Type 12 - AW-14 Discount Schedule: C2
Panel and Console Subclass: DR0
Detail Sheet
console width -5.75
(146)
console width -6.06
(154)
2.87
(73)
2.87
(73)
2.87 min
(73)
2.87 min
(73)
3.00 min
(76)
5.00 min
(127)
3.18
(81)
Console Rear Access Door
(section view showing full and half panel mounted back-to-back)
Console Rear Access Door
(section view showing swing panel and half panel mounted back-to-back)
Notes: Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Operator Enclosures
369 B-Line series electrical enclosures Eaton
Operator Enclosures
Operator Enclosures
370 Eaton B-Line series electrical enclosures
Air Conditioner - General Specifications, Sizing, Selection, & Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372-374
Air Conditioners NEMA 4 or 4X Guardian (DP15, DP21, DP33, DP47, DP50) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375-379
Air Conditioners 480 Volt NEMA 4 or 4X Guardian (DP24) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380
Air Conditioners 480 Volt NEMA 4 or 4X Guardian (DP38, DP52) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381-382
Air Conditioners NEMA 4 or 4X Slimcool Series (SP28, SP36, SP43) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383-385
Air Conditioners Top Mounted NEMA 12 Compact Series Horizontal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386
Air Conditioners Top Mounted NEMA 12 Compact Plus Series Horizontal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
Filter Fans - NEMA 1 Box Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388
Filter Fans NEMA 3R Advantage Sentry Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
Filter Fans Filter-Grille Assemblies Advantage Sentry Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
Filter Fans NEMA 4 or 4X Guardian Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391-392
Filter Fans Filter-Hood Assemblies Guardian Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393
Filter Fans NEMA 12 Filter Fan, Grills, Replacement Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394-398
Heater Calculation Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
PTC Fan Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
PTC Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401
Fan Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402
Small Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403
Electronic Humidity and Temperature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403
Climate Control
Climate Control Products
371 B-Line series electrical enclosures Eaton
Enclosure Climate Control
Heat producing components currently widely used in electronic and industrial equipment enclosures present the problem of
dissipating the heat generated before damage can occur to heat-sensitive parts. In many cases, the problem can be solved by
ventilation, using simple air moving devices. However, in more and more applications the available ambient air is too warm or too
contaminated to be used for the safe dissipation of the unwanted heat. Under those conditions, the life expectancy and performance
of sensitive components may be adversely affected, often causing equipment malfunctions, slowdowns or failures.
In forced convection cooling of enclosures, cooler ambient air is drawn or forced through the components in an enclosure and
discharged. When electronic/electrical enclosures are sealed to keep out moisture, dust, dirt and other contaminants, the heat
generated by the components is trapped and closed-loop cooling (air conditioner or heat exchanger) is needed to maintain the
optimum environment for the components.
*Our product offerings include an extensive array of units for virtually every type of application which customers can select from to
address their enclosure ventilation or cooling requirement.
COOLING PRODUCT SELECTION
Our philosophy is to specify the smallest, least complex cooling device that will satisfy the requirements of the application.
Forced Ventilation Air Cooling
In clean, non-hazardous environments with acceptable ambient temperatures, a simple forced-air cooling system utilizing ambient
air is usually adequate. Combined with a low-cost air filter, such devices generally meet the heat removal needs of typical electronic
and electrical equipment.
Closed-Loop Cooling
In harsh environments involving high temperatures, heavy particulates, oil, or chemicals capable of damaging components, ambient
air must be kept out of the enclosure. Sealed enclosures are generally used, with closed-loop cooling consisting of two separate
circulation systems in a single unit. One system, sealed against the ambient air, cools and recirculates the clean cool air throughout
the enclosure. The second system uses ambient air or water to remove and discharge the heat.
General Specifications for all Air Conditioners Climate Control
372 Eaton B-Line series electrical enclosures
CLOSED-LOOP COOLING: The enclosure interior airflow system is isolated from the ambient airflow system. No ambient air can
invade the cool, dehumidified, sensitive component compartment.
BALL-BEARING MOTORS: All blower motors are UL/CSA Recognized and include automatic-reset thermal overload protection
and double-sealed or double-shielded precision ball bearings. Special permanent lubricants perform over a broad temperature range:
-20ºF (-29ºC) to 250ºF (121ºC). Tube axial fans are rated to perform at 14ºF (-10ºC) to 158ºF (70ºC) and are designed to meet UL,
CSA and VDE.
BLOWERS: All centrifugal blowers are designed and built to provide optimum airflow and pressure for each air conditioner design.
RUGGED CONSTRUCTION: Precision-engineered heavy gauge steel construction of all shells and blowers ensures air conditioners
will stand up under tough applications.*
BAKED POWDER FINISH: Durable, baked-on powder finish is standard. Other finishes are available.*
POWER: Units are available in 115 VAC, 230 VAC or 480 Volt.
REFRIGERANTS: CFC-free R134a Refrigerant is used in all air conditioners for which compatible compressors are available. All
others contain Zero Ozone Depleting Potential (ODP) R410a Refrigerant. The model number reflects the refrigerant. A 4 between
the A and C signifies R134a; a 6 signifies R410a.
FILTERS: Multi-layer grid of sturdy, corrugated aluminum in an aluminum frame. May be reused after washing off accumulations
and spraying with A-16 Recoating Adhesive. Filters must be kept free of accumulations to prevent reduction or loss of performance
and/or damage to equipment. Filters are not required on water-cooled models.
CONDENSATE DISPOSAL: Condensate drain fitting and hose are included. Built-in Condensate Evaporators are standard in many
models. (See Series sections)
POWER CORD: All models have 3-wire power cords. 480 Volt models are supplied with an external junction box for permanent wiring
as a Standard Feature. Single phase UL listed units are supplied with a plug.
INSULATION: All cold components, lines and the evaporator compartment are insulated with high-performance insulation for
maximum efficiency.
GASKETING: All units are fully gasketed for tight, leakproof installation in compliance with the NEMA 12, 3R or 4/4X Enclosure
Ratings.
QUALITY ASSURANCE: Refrigeration system components are kept sealed until charged with refrigerant; all brazed joints are
thoroughly leak-tested; each unit is functionally tested before shipment.
INSTALLATION: Installation instructions, including mounting plan drawings, are included with each unit.
* See Guardian, Guardian 480 Volt for different specifications applicable.
Guardian Series, SlimKool Series, Compact Series, Compact Plus Series, and Advantage Series are brand names of KOOLTRONIC, Inc., Pennington, NJ
Climate Control Products
Air Conditioner Sizing and Selection
Climate Control
Climate Control
373 B-Line series electrical enclosures Eaton
Cooling Electronic Control Cabinets
Most electronic control systems generate a substantial amount of heat during operation. This heat factor is intensified as
electronic controls are made more compact, perform more functions and are placed in confined areas. Additional problems are
encountered when the electronic process control system is located on-line in an industrial setting, rather than in a clean computer
room. The factory environment can be hostile to the point that performance and effective life of the electronic components are
materially reduced or the control system fails completely. Ambient temperature might be excessively high, as that found in a steel
mill. Moisture-laden air and airborne particulate matter might be present to adversely affect the electronic components, as in the
paper manufacturing industry. Air conditioners are designed to perform reliably under many of these harsh conditions and to
provide the cooling and environmental protection required by sensitive electronic production control systems.
Factors Affecting Model Selection
This section is presented as a basic outline or checklist of the various application conditions to be considered when choosing a
cooling unit. These are the factors which must be considered when selecting a cooling unit:
Internal Heat Load
This is the heat dissipated by the electronic controls. It is expressed in watts. One WATT equals 3.413 BTU/HR. Thus, to obtain the
approximate cooling capacity required to remove a specific heat load, the following formula can be used: Watts x 3.413 - BTU/HR.
For example, a heat load of 800 watts, require an air conditioner capable of removing at least 2,730 BTU/HR.
Resistance to Airflow in the Enclosure
Airflow is measured in cubic feet per minute (CFM). To create an air flow of any desired velocity requires that pressure be
produced by the blower. Resistance to this blower-produced air flow is created by obstructions within the cabinet in the air flow
path. The resistance itself is called static pressure (SP) and is measured in inches of water column.The effect of significant
restrictions in the cabinet air flow path are as follows:
• the obstructions cause static pressure.
• static pressure results in a pressure drop, or differential, from the air velocity produced by the blower.
• this reduction in cool air flow will decrease the effective capacity of the cooling unit. Allowance must be made for
static pressure.
Heat Load from the Surroundings
Ambient conditions can cause a heat gain in the enclosure. The rated capacity of the cooling unit must be sufficient to handle this
heat gain. When evaluating the additional heat load gained from the surroundings there are two possible conditions:
• the cabinet is insulated and well sealed
• the cabinet is not insulated.
Cabinet Insulated - Normally, well-insulated cabinets do not gain sufficient heat from the surroundings to affect the air conditioner
operation. BTU/HR ratings for Kooltronic air conditioners have been established at the maximum ambient operating temperature
of 125˚F. A substantial improvement in heat removal occurs when operating in ambient temperatures below 125˚F.
Cabinet Not Insulated - Obviously, this design places more of a burden on the cooling unit. Heat is conducted to the cool side.
Thus, high ambient heat will be readily transmitted into the cooler enclosure. To determine the additional capacity required of an
air conditioner installed in an uninsulated cabinet, the surface area of the enclosure must be calculated to obtain the total effective
heat transfer area. For this calculation, use the surface area of the sides, plus the area of the top and omit the bottom area of the
cabinet.
Air movement outside the uninsulated cabinet will increase the heat conducted from the ambient into the enclosure. When there
is little or no air circulation outside the cabinet, the layer of air immediately adjacent to the exterior cabinet walls acts as an
insulating film. Exterior air movement dissipates this insulating layer of air in proportion to the velocity of the air flow. Substantial
ambient air circulation will increase the transmitted heat load imposed on the cooling unit. If the cabinet being cooled is not air
tight, high ambient relative humidity will adversely affect the cooling effectiveness of the air conditioner. When humid air infiltrates
a poorly sealed enclosure, the air conditioner is required to use up valuable capacity just to condense the moisture from the
internal air. Conversely, if the cabinet is well sealed, high ambient relative humidity has very little effect on the rated capacity of
the air conditioner.
Climate Control Products
The proper selection of an air conditioner is determined by the following criteria:
1) Required cooling capacity BTU/HR.
2) Mounting requirements (top, side or internal mounting)
3) Dimensions of air conditioner & enclosure
Air Conditioners Sizing & Selection
Climate Control
Fourth: (Watts x 3.413) + [1.25 x Area ft.2 x Δ T (˚F)] = BTU/HR.
First Second Third
1 Watt = 3.413 BTU/HR
Determine the internal Watts of heat to be
dissipated.
1 M2 = 10.76 ft2
Calculate the area of the enclosure which is
exposed to the ambient air:
2H” (W”+ D”) + (D” x_W” ) = Area (ft2)
144
1˚C Δ T = 1.8˚FΔ T
Determine the temperature differential
Δ T (˚ F) by subtracting the maximum allowable internal cabinet temperature (Ti
)
from the maximum ambient temperature
outside of the enclosure (To): To - Ti = Δ T
H
W
D
Ti
To
To determine air conditioner capacity required:
Climate Control
Air Conditioner Accessories and Options
Climate Control
Notes: Data subject to change without notice. Consult factory for special requirements.
374
Factory Installed Options
Accessories & Options
• Adapter Plates
• Compressor Heater
• Condensate Evaporator Kit
• Deep Drain Pan Kit
• Enclosure Heater
• Filter Recoating Adhesive
• Internal Corrosion Protection
• Lifting Eyes
• Low Airflow Detector
• Low Ambient Kit
• Mounting Hinge
• Programmable Thermostat
• Replacement Filters
• Short Cycle Protector
• Special Motors, Line Cords, or Connectors
• Special Materials or Finishes
• Stainless or Aluminum Cabinet
• Temperature Alarm
• Weather Protection Kit
Some options may not be available on selected models.
Some options are available as standard features on selected models.
Eaton B-Line series electrical enclosures
Climate Control Products
Climate Control
375
Guardian DP15
NEMA 4 or 4X Air Conditioners
KNA4C1DP15L 4 1160 950 131 -20 55 -29 115/100 60/50 4.3 26 12
KNA4C1DP15LV 4X 1160 950 131 -20 55 -29 115/100 60/50 4.3 26 12
* 115V 60 Hz models perform at reduced capacity when operated at 100V 50 Hz.
** Rating shown for operation at maximum ambient temperature.
95/95 Ambient Temp. **
NEMA BTU/H Rating °F °C * Running Weight
Model Rating Capacity BTU/H Max. Min. Max. Min. Volts Hz Amps lbs kg
Accessories & Options
• Enclosure Heater
• Filter Recoating Adhesive
• Lead-Lag Controller
• Remote Thermostat Relay
• Replacement Filters (P/N: 525F)
• Special Motors, Line Cords or Connectors
• Special Paint Finishes
• Stainless or Aluminum Shell
NEMA
TYPE 4 OR 4X
MAINTAINED
Standard Features
• Baked Powder Finish
• Built-in Condensate Evaporator
• CFC-Free Refrigerant
• Closed-Loop Cooling
• Compressor Short Cycle Protector
• Epoxy-Coated Condenser Coils
• Filter
• Heavy-duty Steel Shell
• Internal Corrosion Protection (NEMA 4X Models)
• Low Temperature Control Thermostat*
• NEMA 12, 3R and 4 Ratings Maintained (UL50)
• Six-Foot [1.8m] (Minimum) 3-Wire Power Cord
• Stainless Steel Shell (NEMA 4X Models)
• UL/CUL Listed
* Transitioning to programmable controls
Drawings
1 Condenser air inlet (ambient air in)
2 Condenser outlet (warm ambient air out)
3 Warm air return from enclosure
4 Cool air outlet to enclosure
Performance
Operation within shaded area not recommended.
B-Line series electrical enclosures Eaton
Transitioning to
ANSI 61 Gray finish
Notes: Data subject to change without notice.
Consult factory for special requirements. Dimensions are in inches. Millimeters shown in [ ] are for reference only.
Climate Control Products
Climate Control
376
Guardian DP21
NEMA 4 or 4X Air Conditioners
Accessories & Options
• Enclosure Heater
• Filter Recoating Adhesive
• Lead-Lag Controller
• Remote Thermostat Relay
• Replacement Filters (P/N: 8388F)
• Special Motors, Line Cords or Connectors
• Special Paint Finishes
• Stainless or Aluminum Shell
NEMA
TYPE 4 OR 4X
MAINTAINED
Standard Features
• Baked Powder Finish
• Built-in Condensate Evaporator
• CFC-Free Refrigerant
• Closed-Loop Cooling
• Compressor Short Cycle Protector
• Condenser Blower Controller
• Epoxy-Coated Condenser Coils
• Filter
• Heavy-duty Steel Shell
• Internal Corrosion Protection (NEMA 4X Models)
• Low Temperature Control Thermostat*
• NEMA 4 or 4X Rating Maintained (UL50)
• Six-Foot [1.8m] (Minimum) 3-Wire Power Cord
• Stainless Steel Shell (NEMA 4X Models)
• UL/CUL Listed
* Transitioning to programmable controls
Performance
Operation within shaded area not recommended.
1 Condenser air inlet (ambient air in)
2 Condenser outlet (warm ambient air out)
3 Warm air return from enclosure
4 Cool air outlet to enclosure
Drawings
Eaton B-Line series electrical enclosures
Transitioning to
ANSI 61 Gray finish
Notes: Data subject to change without notice.
Consult factory for special requirements. Dimensions are in inches. Millimeters shown in [ ] are for reference only.
Climate Control Products
KNA4C3DP21L 4 3000 2470 131 -20 55 -29 115/100 60/50 6.0/5.0 54 25
KNA4C3DP21LV 4X 3000 2470 131 -20 55 -29 115/100 60/50 6.0/5.0 54 25
* 115V 60 Hz models perform at reduced capacity when operated at 100V 50 Hz.
** Rating shown for operation at maximum ambient temperature.
95/95 Ambient Temp. **
NEMA BTU/H Rating °F °C * Running Weight
Model Rating Capacity BTU/H Max. Min. Max. Min. Volts Hz Amps lbs kg
Climate Control
377
Guardian DP33
NEMA 4 or 4X Air Conditioners
KNA4C5DP33L 4 5000 4000 131 -20 55 -29 115/100 60/50 10.6/10.2 95 43
KNA4C5DP33LV 4X 5000 4000 131 -20 55 -29 115/100 60/50 10.6/10.2 95 43
* 115V 60 Hz models perform at reduced capacity when operated at 100V 50 Hz.
** Rating shown for operation at maximum ambient temperature.
95/95 Ambient Temp. **
NEMA BTU/H Rating °F °C * Running Weight
Model Rating Capacity BTU/H Max. Min. Max. Min. Volts Hz Amps lbs kg
NEMA
TYPE 4 OR 4X
MAINTAINED
Standard Features
• Baked Powder Finish
• Built-in Condensate Evaporator
• CFC-Free Refrigerant
• Condenser Impeller Speed Controller
• Epoxy-Coated Condenser Coils
• Filter
• Heavy-duty Steel Shell
• Internal Corrosion Protection (NEMA 4X Models)
• Low Temperature Control Thermostat*
• NEMA 4 or 4X Rating Maintained (UL50)
• Six-Foot [1.8m] (Minimum) 3-Wire Power Cord
• Stainless Steel Shell (NEMA 4X Models)
• UL/CUL Listed
* Transitioning to programmable controls
Performance
Operation within shaded area not recommended.
1 Condenser air inlet (ambient air in)
2 Condenser outlet (warm ambient air out)
3 Warm air return from enclosure
4 Cool air outlet to enclosure
Accessories & Options
• Compressor Short Cycle Protector
• Enclosure Heater
• Filter Recoating Adhesive
• Lead-Lag Controller
• Other Voltages and Frequencies
• Remote Thermostat Relay
• Replacement Filters (P/N: 9501F)
• Special Motors, Line Cords or Connectors
• Special Materials and Finishes
• Temperature Alarm
• Available in 230V Models
Drawings
B-Line series electrical enclosures Eaton
Transitioning to
ANSI 61 Gray finish
Notes: Data subject to change without notice.
Consult factory for special requirements. Dimensions are in inches. Millimeters shown in [ ] are for reference only.
Climate Control Products
Climate Control
378
Guardian DP47
NEMA 4 or 4X Air Conditioners
KNA4C9DP47L 4 9000 7400 131 -20 55 -29 115/100 60/50 19.2 135 61
KNA4C9DP47LV 4X 9000 7400 131 -20 55 -29 115/100 60/50 19.2 135 61
* 115V 60 Hz models perform at reduced capacity when operated at 100V 50 Hz.
** Rating shown for operation at maximum ambient temperature.
95/95 Ambient Temp. **
NEMA BTU/H Rating °F °C * Running Weight
Model Rating Capacity BTU/H Max. Min. Max. Min. Volts Hz Amps lbs kg
NEMA
TYPE 4 OR 4X
MAINTAINED
Standard Features
• Baked Powder Finish
• Built-in Condensate Evaporator
• CFC-Free Refrigerant
• Condenser Impeller Speed Controller
• Epoxy-Coated Condenser Coils
• Filter
• Heavy-duty Steel Shell
• Internal Corrosion Protection (NEMA 4X Models)
• Low Temperature Control Thermostat*
• NEMA 4 or 4X Rating Maintained (UL50)
• Six-Foot [1.8m] (Minimum) 3-Wire Power Cord
• Stainless Steel Shell (NEMA 4X Models)
• UL/CUL Listed
* Transitioning to programmable controls
Accessories & Options
• Compressor Short Cycle Protector
• Enclosure Heater
• Filter Recoating Adhesive
• Lead-Lag Controller
• Other Voltages and Frequencies
• Remote Thermostat Relay
• Replacement Filters (P/N: 8001F)
• Special Motors, Line Cords or Connectors
• Special Materials and Finishes
• Temperature Alarm
• Available in 230V Models
Drawings
Performance
Operation within shaded area not recommended.
Eaton B-Line series electrical enclosures
Transitioning to
ANSI 61 Gray finish
Notes: Data subject to change without notice.
Consult factory for special requirements. Dimensions are in inches. Millimeters shown in [ ] are for reference only.
1 Condenser air inlet (ambient air in)
2 Condenser outlet (warm ambient air out)
3 Warm air return from enclosure
4 Cool air outlet to enclosure
Climate Control Products
Climate Control
379
Guardian DP50
NEMA 4 or 4X Air Conditioners
K2NA6C14DP50L 4 14000 13000 131 -20 55 -29 230 60 13.5 207 94
K2NA6C14DP50LV 4X 14000 13000 131 -20 55 -29 230 60 13.5 207 94
* 115V 60 Hz models perform at reduced capacity when operated at 100V 50 Hz.
** Rating shown for operation at maximum ambient temperature.
95/95 Ambient Temp. **
NEMA BTU/H Rating °F °C * Running Weight
Model Rating Capacity BTU/H Max. Min. Max. Min. Volts Hz Amps lbs kg
NEMA
TYPE 4 OR 4X
MAINTAINED
Standard Features
• Baked Powder Finish
• Built-In Condensate Evaporator
• Closed-Loop Cooling
• Condenser Blower Controller
• Epoxy-Coated Condenser Coils
• Filters (2)
• Heavy-duty Steel Shell
• Internal Corrosion Protection (NEMA 4X Models)
• Low Temperature Control Thermostat*
• NEMA 4 or 4X Rating Maintained (UL50)
• Six-Foot [1.8m] (Minimum) 3-Wire Power Cord
• Stainless Steel Shell (NEMA 4X Models)
• UL/CUL Listed
• Zero ODP Refrigerant
* Transitioning to programmable controls
Performance
Operation within shaded area not recommended.
* Operation at 50Hz will be 10% less.
Accessories & Options
• Compressor Short Cycle Protector
• Enclosure Heater
• Filter Recoating Adhesive
• Lead-Lag Controller
• Other Voltages and Frequencies
• Remote Thermostat Relay
• Replacement Filters (P/N: 13658F)
• Special Motors, Line Cords or Connectors
• Special Materials and Finishes
• Temperature Alarm
Drawings
1 Condenser air inlet (ambient air in)
2 Condenser outlet (warm ambient air out)
3 Warm air return from enclosure
4 Cool air outlet to enclosure
B-Line series electrical enclosures Eaton
Transitioning to
ANSI 61 Gray finish
Notes: Data subject to change without notice.
Consult factory for special requirements. Dimensions are in inches. Millimeters shown in [ ] are for reference only.
Climate Control Products
Climate Control
380
Guardian Series DP24
480 Volt 1-Phase NEMA 4 or 4X Air Conditioners
K3NA4C3DP24L 4 3000 2500 125 -20 52 -29 480/1 60 1.4 61 27
K3NA4C3DP24LV 4X 3000 2500 125 -20 52 -29 480/1 60 1.4 61 27
* Rating shown for operation at maximum ambient temperature.
95/95 Ambient Temp. *
NEMA BTU/H Rating °F °C Running Weight
Model Rating Capacity BTU/H Max. Min. Max. Min. Volts Hz Amps lbs kg
NEMA
TYPE 4 OR 4X
MAINTAINED
Standard Features
• Baked Powder Finish
• 480 Volt 1-Phase
• Built-In Condensate Evaporator
• CFC - Free Refrigerant
• Closed-Loop Cooling
• Compressor Short Cycle Protector
• Condenser Blower Controller
• Epoxy-Coated Condenser Coils
• Filter
• Heavy-duty Steel Shell
• Internal Corrosion Protection (NEMA 4X Models)
• Low Temperature Control Thermostat*
• NEMA 4 or 4X Rating Maintained (UL50)
• Stainless Steel Shell (NEMA 4X Models)
• UL/CUL Listed
* Transitioning to programmable controls
Performance
Operation within shaded area not recommended.
Accessories & Options
• Enclosure Heater
• Filter Recoating Adhesive
• Lead-Lag Controller
• Remote Thermostat Relay
• Replacement Filters (P/N: 8388F)
• Special Materials and Finishes
• Stainless or Aluminum Shell
Drawings
1 Condenser air inlet (ambient air in)
2 Condenser outlet (warm ambient air out)
3 Warm air return from enclosure
4 Cool air outlet to enclosure
Eaton B-Line series electrical enclosures
Transitioning to
ANSI 61 Gray finish
Notes: Data subject to change without notice.
Consult factory for special requirements. Dimensions are in inches. Millimeters shown in [ ] are for reference only.
Climate Control Products
Climate Control
381
Guardian Series DP38
480 Volt 3-Phase NEMA 4 or 4X Air Conditioners
K3NA4C5DP38L 4 5000 4800 131 0 55 -18 480 60 2.0 115 52
K3NA4C5DP38LV 4X 5000 4800 131 0 55 -18 480 60 2.0 115 52
* Rating shown for operation at maximum ambient temperature.
95/95 Ambient Temp. *
NEMA BTU/H Rating °F °C Running Weight
Model Rating Capacity BTU/H Max. Min. Max. Min. Volts Hz Amps lbs kg
NEMA
TYPE 4 OR 4X
MAINTAINED
Standard Features
• Baked Powder Finish
• Built-In Condensate Evaporator
• CFC - Free Refrigerant
• Closed-Loop Cooling
• Condenser Impeller Speed Controller
• Epoxy-Coated Condenser Coils
• External Junction Box for Permanent
Wiring Connections
• Filter
• Heavy-duty Steel Shell
• Internal Corrosion Protection (NEMA 4X Models)
• Low Temperature Control Thermostat*
• NEMA 4 or 4X Rating Maintained (UL50)
• Phase Sequence/Phase Loss Detector/
Under Voltage Monitor
• Stainless Steel Shell (NEMA 4X Models)
• UL/CUL Listed
* Transitioning to programmable controls
Performance
Operation within shaded area not recommended.
Accessories & Options
• Compressor Short Cycle Protector
• Enclosure Heater
• Filter Recoating Adhesive
• Lead-Lag Controller
• Remote Thermostat Relay
• Replacement Filters (P/N: 9501F)
• Special Paint Finishes
• Temperature Alarm
Drawings
1 Condenser air inlet (ambient air in)
2 Condenser outlet (warm ambient air out)
3 Warm air return from enclosure
4 Cool air outlet to enclosure
B-Line series electrical enclosures Eaton
Transitioning to
ANSI 61 Gray finish
Notes: Data subject to change without notice.
Consult factory for special requirements. Dimensions are in inches. Millimeters shown in [ ] are for reference only.
Climate Control Products
Climate Control
382
Guardian Series DP52
480-Volt 3-Phase NEMA 4 or 4X Air Conditioners
K3NA4C7DP52L 4 7000 6300 131 0 55 -18 480 60 3.0 160 72
K3NA4C7DP52LV 4X 7000 6300 131 0 55 -18 480 60 3.0 160 72
K3NA4C9DP52L 4 9000 8100 131 0 55 -18 480 60 4.0 164 75
K3NA4C9DP52LV 4X 9000 8100 131 0 55 -18 480 60 4.0 164 75
* Rating shown for operation at maximum ambient temperature.
95/95 Ambient Temp. *
NEMA BTU/H Rating °F °C Running Weight
Model Rating Capacity BTU/H Max. Min. Max. Min. Volts Hz Amps lbs kg
NEMA
TYPE 4 OR 4X
MAINTAINED
Standard Features
• Baked Powder Finish
• Built-In Condensate Evaporator
• CFC - Free Refrigerant
• Closed-Loop Cooling
• Condenser Impeller Speed Controller
• Epoxy-Coated Condenser Coils
• External Junction Box for Permanent
Wiring Connections
• Filter
• Heavy-duty Steel Shell
• Internal Corrosion Protection (NEMA 4X Models)
• Low Temperature Control Thermostat*
• NEMA 4 or 4X Rating Maintained (UL50)
• Phase Sequence/Phase Loss Detector/
Under Voltage Monitor
• Stainless Steel Shell (NEMA 4X Models)
• UL/CUL Listed
* Transitioning to programmable controls
Accessories & Options
• Compressor Short Cycle Protector
• Enclosure Heater
• Filter Recoating Adhesive
• Lead-Lag Controller
• Remote Thermostat Relay
• Replacement Filters (P/N: 8001F)
• Special Paint Finishes
• Temperature Alarm
Drawings
1 Condenser air inlet (ambient air in)
2 Condenser outlet (warm ambient air out)
3 Warm air return from enclosure
4 Cool air outlet to enclosure Operation within shaded area not recommended.
Performance
Eaton B-Line series electrical enclosures
Transitioning to
ANSI 61 Gray finish
Notes: Data subject to change without notice.
Consult factory for special requirements. Dimensions are in inches. Millimeters shown in [ ] are for reference only.
Climate Control Products
Climate Control
383
SlimKool Series (narrow width) SP28
NEMA 4 or 4X Air Conditioners
KNA4C4SP28L 4 4000 3700 131 -20 55 -29 115/100 60/50 8.3 85 38.5
KNA4C4SP28LV 4X 4000 3700 131 -20 55 -29 115/100 60/50 8.3 85 38.5
* Rating shown for operation at maximum ambient temperature.
95/95 Ambient Temp. *
NEMA BTU/H Rating °F °C Running Weight
Model Rating Capacity BTU/H Max. Min. Max. Min. Volts Hz Amps lbs kg
NEMA
TYPE 12, 3R, & 4
MAINTAINED
(4X OPTIONAL)
Standard Features
• Built-In Condensate Evaporator
• CFC - Free Refrigerant
• Closed-Loop Cooling
• Compact Design/Slim Mounting Footprints
• Compressor Short Cycle Protector
• Condenser Impeller Cycling Controller
• Epoxy-Coated Evaporator & Condenser Coils
• Filter
• Heavy-duty Steel Shell with ANSI Gray Polyester
Powder Coating
• Internal Corrosion Protection
• NEMA 12, 3R, and 4 Ratings
Maintained (UL50) (4X Optional)
• Programmable Temperature Alarm
• Programmable Thermostat
• Stainless Steel Shell (NEMA 4X Models)
• UL/CUL Listed
Accessories & Options
• Enclosure Heater
• Filter Recoating Adhesive
• Lead-Lag Controller
• Mounting Adapter Plates
• Remote Monitoring
• Remote Thermostat Relay
• Replacement Filters (P/N: 9501F)
• Available in 230V and 480V Models
1 Condenser air inlet (ambient air in)
2 Condenser outlet (warm ambient air out)
3 Warm air return from enclosure
4 Cool air outlet to enclosure
Performance
Operation within shaded area not recommended.
Drawings
B-Line series electrical enclosures Eaton
Notes: Data subject to change without notice.
Consult factory for special requirements. Dimensions are in inches. Millimeters shown in [ ] are for reference only.
Climate Control Products
Climate Control
384
SlimKool Series (narrow width) SP36
NEMA 4 or 4X Air Conditioners
KNA4C6SP36L 4 6000 5600 131 -20 55 -29 115/100 60/50 9.6 100 45.3
KNA4C6SP36LV 4X 6000 5600 131 -20 55 -29 115/100 60/50 9.6 100 45.3
KNA4C8SP36L 4 8000 7500 131 -20 55 -29 115/100 60/50 14.4 100 45.3
KNA4C8SP36LV 4X 8000 7500 131 -20 55 -29 115/100 60/50 14.4 100 45.3
* Rating shown for operation at maximum ambient temperature.
95/95 Ambient Temp. *
NEMA BTU/H Rating °F °C Running Weight
Model Rating Capacity BTU/H Max. Min. Max. Min. Volts Hz Amps lbs kg
NEMA
TYPE 12, 3R, & 4
MAINTAINED
(4X OPTIONAL)
Standard Features
• Built-In Condensate Evaporator
• CFC - Free Refrigerant
• Closed-Loop Cooling
• Compact Design/Slim Mounting Footprints
• Compressor Short Cycle Protector
• Condenser Impeller Cycling Controller
• Epoxy-Coated Evaporator & Condenser Coils
• Filter
• Heavy-duty Steel Shell with ANSI Gray
Polyester Powder Coating
• Internal Corrosion Protection
• NEMA 12, 3R, and 4 Ratings
Maintained (UL50) (4X Optional)
• Programmable Temperature Alarm
• Programmable Thermostat
• Stainless Steel Shell (NEMA 4X Models)
• UL/CUL Listed
Accessories & Options
• Enclosure Heater
• Filter Recoating Adhesive
• Lead-Lag Controller
• Mounting Adapter Plates
• Remote Monitoring
• Remote Thermostat Relay
• Replacement Filters (P/N: 9502F)
• Available in 230V Models
Performance
Operation within shaded area not recommended.
Drawings
1 Condenser air inlet (ambient air in)
2 Condenser outlet (warm ambient air out)
3 Warm air return from enclosure
4 Cool air outlet to enclosure
Eaton B-Line series electrical enclosures
Notes: Data subject to change without notice.
Consult factory for special requirements. Dimensions are in inches. Millimeters shown in [ ] are for reference only.
Climate Control Products